V D E SERIES MULTI-PURPOSE POWER LINE FILTERS SPECIFICATIONS INTRODUCTIONS Two-stage filters are for susceptibility use when equipment impedance at radiation frequency is low. 1. Maximum leakage current each line-to-ground: @115VAC 60Hz: 0.45mA @250VAC 50Hz: 0.90mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC COMPONENTS C1(uF) C2(uF) L1(mH) L2(mH) Cy(pF) R(K ) 1.0 30 0.22 1.7 70 0.22 5500 330K 0.22 1.2 40 0.47 1.73 30 SERIES DIMENSIONS MINIMUM INSERTION LOSS IN dB COMMONMODE(L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 30 3A 12 25 35 50 45 40 6A 23 40 50 55 55 40 10A 10 20 30 50 45 35 * * 20A 20 20 35 45 45 30 DIFFERENTIALMODE(L-L) IN 50 OHM SYSTEM 3A 30 50 60 60 70 50 6A 25 35 50 55 55 50 10A 25 55 60 60 55 55 ** 20A 25 50 50 50 45 45 PART NO. 03DVCG5 06DVCG5 10DVCG5 20DVGG5 A GENERAL PURPOSE TWO-STAGE FILTERS PART NO. 03DVCG5 06DVCG5 10DVCG5 20DVCG5 DIMENSIONS IN INCHES/mm B C D E 3.25 82.5 1.90 48.3 3.75 95.2 2.06 52.3 5.25 130.5 3.40 86.4 1.15 29.2 1.54 39.1 2.38 60.5 2.77 70.4 2.94 74.7 3.34 84.8 3.75 95.3 4.14 105.1 VDE approved in 8A ** VDE approved in 16A INSERTION LOSS (TYPICAL) 03DVCG5 06DVCG5 COMMON MODE DIFF. MODE COMMON MODE DIFF. MODE 10DVCG5 20DVGG5 100 dB 100 dB 80 dB 80 dB 60 dB 60 dB 40 dB 40 dB 20 dB 20 dB 0 dB 10K 100K 1M 0 dB 10M 6-12 10K COMMON MODE DIFF. MODE COMMON MODE DIFF. MODE 100K 1M 10M ELECTRICAL SCHEMATIC L L' L I N E C1 C1 Cy L1 R L O A D C2 L2 Cy N N' G MECHANICAL CONSTRUCTION E D C MAX. B MAX. 0.188(2X) 4.8(2X) CG5 D 0.255X0.157(2X) 6.5X4.0(2X) B MAX. 2.0 50.8 E MAX. A MAX. C MAX. GENERAL PURPOSE TWO-STAGE FILTERS A MAX. GG5 UNIT: 6-13 INCH mm