V D E SERIES MULTI-PURPOSE POWER LINE FILTERS SPECIFICATIONS INTRODUCTION Two-stage filters providing excellent suppression at high frequency. 1. Maximum leakage current each line-to-ground: @ 115VAC 60Hz: 0.50mA @ 250VAC 50Hz: 1.00mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC COMPONENTS C1(uF) 0.22 C2(uF) L1(mH) 1.0 0.22 1.7 1.2 0.47 1.73 L2(mH) Cy(pF) 30 70 5500 40 30 R(K ) 330K SERIES DIMENSIONS MINIMUM INSERTION LOSS IN dB PART NO. COMMONMODE (L-G)IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 30 3A 12 20 30 60 60 45 6A 25 30 45 55 55 45 10A 15 20 30 60 55 45 * 20A 20 25 30 55 55 45 DIFFERENTIALMODE (L-L) IN 50 OHM SYSTEM 3A 25 50 60 45 50 50 6A 25 35 50 50 50 45 10A 25 50 50 45 45 45 * 20A 25 55 55 55 50 45 03DWCG5 06DWCG5 10DWCG5 20DWGG5 A GENERAL PURPOSE TWO-STAGE FILTERS PART NO. 03DWCG5 06DWCG5 10DWCG5 20DWCG5 DIMENSIONS IN INCHES/mm B C D E 3.25 82.5 1.90 48.3 3.75 95.2 2.06 52.3 5.25 130.5 3.40 86.4 1.15 29.2 1.54 39.1 2.38 60.5 2.77 70.4 2.94 74.7 3.34 84.8 3.75 95.3 4.14 105.1 VDE approved in 8A * VDE approved in 16A INSERTION LOSS (TYPICAL) 03DWCG5 06DWCG5 COMMON MODE DIFF. MODE COMMON MODE DIFF. MODE 10DWCG5 20DWGG5 100dB 100dB 80 dB 80 dB 60 dB 60 dB 40 dB 40 dB 20 dB 20 dB COMMON MODE DIFF. MODE COMMON MODE DIFF. MODE 0 dB 0 dB 10K 100K 1M 10K 10M 6-14 100K 1M 10M ELECTRICAL SCHEMATIC R1 L L L' L I N E C1 C1 Cy R L1 Cy L2 Cy N Cy C2 L' L I N E L O A D C1 C1 Cy R Cy L1 C2 L2 Cy Cy L O A D N N' N' G G R1 20A. 3A. 6A. 10A. R1=330(Ohm) MECHANICAL CONSTRUCTION E D B MAX. 0.188 4.8 C MAX. CG5 D 0.255X0.157 6.5X4.0 B MAX. 2.0 50.8 E MAX. A MAX. C MAX. GENERAL PURPOSE TWO-STAGE FILTERS A MAX. GG5 UNIT: 6-15 INCH mm