DS

V
D E
SERIES MULTI-PURPOSE POWER LINE FILTERS
INTRODUCTION
SPECIFICATIONS
1. Maximum leakage current each
line-to-ground: @ 115VAC 60Hz: 0.45mA
@ 250VAC 50Hz: 0.90mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
Two-stage filters are for susceptibility use when
equipment impedance at radiation frequency is low.
COMPONENTS
PART NO.
03DSCG5
06DSCG5
10DSCG5
20DSCG5
C1(uF) C2(uF) L1(mH) L2(mH) Cy(pF) R(K )
30
1.0
0.22
70
1.7
0.22
5500
330K
40
1.2
0.55
30
0.93
MINIMUM INSERTION LOSS IN dB
PART NO.
COMMONMODE(L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
.15
.50
1.0
5.0
10
30
3A
12
25
30
45
60
35
6A
25
30
30
35
50
45
10A
15
20
25
40
45
40
** 20A
12
20
30
35
40
40
DIFFERENTIALMODE(L-L) IN 50 OHM SYSTEM
3A
20
50
60
45
45
45
6A
30
25
40
40
40
40
10A
25
50
50
45
45
45
25
60
60
50
50
45
** 20A
03DSCG5
06DSCG5
10DSCG5
20DSGG5
A
DIMENSIONS IN INCHES/mm
B
C
D
E
3.25
82.5
1.90
48.3
3.75
95.2
2.06
52.3
5.25
130.5
3.40
86.4
1.15
29.2
1.54
39.1
2.38
60.5
2.77
70.4
2.94
74.7
3.34
84.8
3.75
95.3
4.14
105.1
VDE approved in 8A
* * VDE approved in 16A
INSERTION LOSS (TYPICAL)
03DSCG5
06DSCG5
COMMON MODE
DIFF. MODE
COMMON MODE
DIFF. MODE
10DSCG5
20DSGG5
100 dB
100 dB
80 dB
80 dB
60 dB
60 dB
40 dB
40 dB
20 dB
20 dB
0 dB
10K
100K
1M
0 dB
10M
6-10
10K
100K
COMMON MODE
DIFF. MODE
COMMON MODE
DIFF. MODE
1M
10M
GENERAL PURPOSE TWO-STAGE FILTERS
SERIES DIMENSIONS
ELECTRICAL SCHEMATIC
R1
L
L'
L
I
N
E
C1
R
Cy
L2
L1
Cy
N
C2
L
L
O
A
D
N'
L'
L
I
N
E
R
C1
Cy
L1
L
O
A
D
C2
L2
Cy
N
G
N'
G
R1
20A.
R1=330 (Ohm)
A MAX.
MECHANICAL CONSTRUCTION
E
D
B MAX.
0.188
4.8
C MAX.
CG5
0.255X0.157
6.5X4.0
B MAX.
D
2.0
50.8
E MAX.
A MAX.
C MAX.
GENERAL PURPOSE TWO-STAGE FILTERS
3A. 6A. 10A.
GG5
UNIT: INCH
mm
6-11