V D E SERIES MULTI-PURPOSE POWER LINE FILTERS INTRODUCTION SPECIFICATIONS 1. Maximum leakage current each line-to-ground: @ 115VAC 60Hz: 0.45mA @ 250VAC 50Hz: 0.90mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC Two-stage filters are for susceptibility use when equipment impedance at radiation frequency is low. COMPONENTS PART NO. 03DSCG5 06DSCG5 10DSCG5 20DSCG5 C1(uF) C2(uF) L1(mH) L2(mH) Cy(pF) R(K ) 30 1.0 0.22 70 1.7 0.22 5500 330K 40 1.2 0.55 30 0.93 MINIMUM INSERTION LOSS IN dB PART NO. COMMONMODE(L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 30 3A 12 25 30 45 60 35 6A 25 30 30 35 50 45 10A 15 20 25 40 45 40 ** 20A 12 20 30 35 40 40 DIFFERENTIALMODE(L-L) IN 50 OHM SYSTEM 3A 20 50 60 45 45 45 6A 30 25 40 40 40 40 10A 25 50 50 45 45 45 25 60 60 50 50 45 ** 20A 03DSCG5 06DSCG5 10DSCG5 20DSGG5 A DIMENSIONS IN INCHES/mm B C D E 3.25 82.5 1.90 48.3 3.75 95.2 2.06 52.3 5.25 130.5 3.40 86.4 1.15 29.2 1.54 39.1 2.38 60.5 2.77 70.4 2.94 74.7 3.34 84.8 3.75 95.3 4.14 105.1 VDE approved in 8A * * VDE approved in 16A INSERTION LOSS (TYPICAL) 03DSCG5 06DSCG5 COMMON MODE DIFF. MODE COMMON MODE DIFF. MODE 10DSCG5 20DSGG5 100 dB 100 dB 80 dB 80 dB 60 dB 60 dB 40 dB 40 dB 20 dB 20 dB 0 dB 10K 100K 1M 0 dB 10M 6-10 10K 100K COMMON MODE DIFF. MODE COMMON MODE DIFF. MODE 1M 10M GENERAL PURPOSE TWO-STAGE FILTERS SERIES DIMENSIONS ELECTRICAL SCHEMATIC R1 L L' L I N E C1 R Cy L2 L1 Cy N C2 L L O A D N' L' L I N E R C1 Cy L1 L O A D C2 L2 Cy N G N' G R1 20A. R1=330 (Ohm) A MAX. MECHANICAL CONSTRUCTION E D B MAX. 0.188 4.8 C MAX. CG5 0.255X0.157 6.5X4.0 B MAX. D 2.0 50.8 E MAX. A MAX. C MAX. GENERAL PURPOSE TWO-STAGE FILTERS 3A. 6A. 10A. GG5 UNIT: INCH mm 6-11