HIGH PERFORMANCE FILTERS SERIES SPECIFICATIONS INTRODUCTIONS 1. Two-stage filters provide high performance in suppressing both line-to-line and line-to-ground noise. 2. All part numbers are UL recognized, CSA certified and VDE approved. 1. Maximum leakage current each line-to-ground @ 115VAC 60Hz: 0.25mA @ 250VAC 50Hz: 0.45mA 2. Hipot rating (one minute) line-to-ground: 2250VDC line-to-line: 1450VDC 3. Operating frequency: 50/60Hz 4. Rated voltage: 115/250VAC GENERAL PURPOSE TWO-STAGE FILTERS COMPONENTS PART NO. 02DRCG5 02DRCW5 03DRCG5 03DRCW5 03DRDG3S 03DRDW3S 05DRCG5 05DRCW5 05DRDG3 05DRDG3S 05DRDW3S 10DRCG5 10DRCS5 10DRCW5 10DRDG3 * 15DRCG5 20DRGG5 20DRGS5 C1,C2,C3(uF) SERIES DIMENSIONS L1,L2(mH) 0.1 2.4 PART NO. 1.7 02DRCG5 2.8 02DRCW5 1.6 03DRCG5 2.7 1.3 1.3 0.22 03DRCW5 03DRDG3S 1.0 03DRDW3S 0.1 0.9 0.22 1.0 05DRCG5 05DRCW5 R: 2.2M , Cy: 3300pF. No safety approval yet, R: 1.0M * VDE approved to 16A/250VAC, C2: 0.33 uF 05DRDG3 05DRDG3S ELECTRICAL SCHEMATIC 05DRDW3S 10DRCG5 L' L L I N E Cy C1 V D E L1 R C2 C3 L2 Cy L O A D 10DRCS5 N N' G G' 10DRCW5 10DRDG3 15DRCG5 20DRGG5 20DRGS5 6-7 A 3.25 82.5 2.08 52.8 3.75 95.2 2.58 65.5 3.14 79.8 2.55 64.8 3.75 95.2 2.58 65.5 4.33 110.0 3.14 79.8 2.55 64.8 3.75 95.2 3.87 98.3 2.50 63.5 4.35 110.5 3.75 95.2 5.14 130.5 DIMENSIONS IN INCHES/mm B C D 2.38 60.5 1.82 46.2 2.02 51.3 2.04 51.8 2.02 51.3 2.04 51.8 2.20 55.9 1.15 29.2 E 2.77 70.4 2.77 70.4 2.94 74.7 3.34 84.8 1.28 32.5 1.575 40.00 0.61 15.5 1.15 29.2 2.94 74.7 3.34 84.8 1.27 32.3 0.63 16.0 1.575 40.00 0.61 15.5 2.02 51.3 1.52 38.6 2.94 74.4 3.34 84.5 2.22 56.4 2.08 52.8 1.27 32.3 1.79 45.5 1.575 40.01 2.94 74.7 0.63 16.0 3.36 85.3 3.33 84.6 1.52 38.6 3.75 95.3 4.14 105.1 INSERTION LOSS (TYPICAL) COMMON MODE 02DRCG5 COMMON MODE 05DRCG5 10DRCG5 10DRDG3 DIFF. MODE DIFF. MODE 80 dB 80 dB 60 dB 60 dB 40 dB 40 dB 20 dB 20 dB 100K 10K 1M 0 dB 10M 1M 100K 10K DIFF. MODE DIFF. MODE 10M GENERAL PURPOSE TWO-STAGE FILTERS 0 dB COMMON MODE COMMON MODE MINIMUM INSERTION LOSS IN dB COMMON MODE (L-G) IN 50 OHM SYSTEM CURRENT FREQUENCY-MHz RATING .15 .50 1.0 5.0 10 30 2 40 60 65 55 50 40 3, 5A 40 60 65 65 60 45 3, 5A(S) 38 60 65 55 45 40 10A 30 60 65 50 45 40 15A 23 45 50 45 40 30 20A 20 35 40 50 55 40 DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM 2 5 50 65 60 54 46 3, 5A 12 60 65 60 54 46 3, 5A(S) 10 65 70 70 60 50 10A 7 53 60 55 45 40 15A 8 30 40 45 40 40 20A 7 55 50 50 55 40 MECHANICAL CONSTRUCTION E MAX. D BLUE 0.188 4.8 BLUE BROWN BROWN C MAX. B MAX. A MAX. G/Y ALL WIRE LEADS 4.0" LONG MIN. CW5 D 0.255X0.157 6.5X4.0 B MAX. E MAX. 2.0 50.8 A MAX. C MAX. GG5 6-8 UNIT: INCH mm 2.0 0.255X0.157 6.5X4.0 50.8 MECHANICAL CONSTRUCTION D B MAX. E MAX. #8-32 C MAX. A MAX. GS5 A MAX. E C MAX. B MAX. 0.188 4.8 CG5 E D B MAX. #8-32 0.188 4.8 C MAX. A MAX. CS5 E B 1 5 D 2 A #6-32X1/4 TAPPED INSERT 1.575 + -0.005 40.0+ -0.13 C 0.157 4.0 +0.005 0.91- 0 +0.13 23.1-0 R0.24MAX. R6.0MAX. DG3/DG3S 1.22 + -0.005 31.0+ -0.13 SUGGESTED MOUNTING CUTOUT E A B G/Y 1 5 D 2 BLUE DW3S R0.24MAX. R6.0MAX. 6-9 BROWN #6-32X1/4 TAPPED INSERT 0.157 4.0 1.22 + -0.005 31.0+ -0.13 SUGGESTED MOUNTING CUTOUT C 1.575 + -0.005 40.0+ -0.13 +0.005 0.91- 0 +0.13 23.1-0 GENERAL PURPOSE TWO-STAGE FILTERS D ALL WIRE LEADS 4.0" LONG MIN. UNIT: INCH mm