MIMMF2X100J040D 400V 100A FRED Module RoHS Compliant PRODUCT FEATURES Ultrafast Reverse Recovery Time Soft Reverse Recovery Characteristics Low Reverse Recovery Loss Electrically Isolated by DBC Ceramic High System Power Density Popular SOT-227 Package APPLICATIONS Inversion Welder Uninterruptible Power Supply (UPS) Plating Power Supply Ultrasonic Cleaner and Welder Converter & Chopper Power Factor Correction (PFC) Circuit ABSOLUTE MAXIMUM RATINGS Symbol Parameter TC=25°C unless otherwise specified Test Conditions Values Unit VR Maximum D.C. Reverse Voltage 400 V VRRM Maximum Repetitive Reverse Voltage 400 V TC=90°C, Per Diode 100 A TC=90°C, Per Moudle 200 A TC=100°C, 20KHz, Per Moudle 150 A RMS Forward Current TC=90°C, Per Diode 150 A Non-Repetitive Surge 1/2 Cycle , 50Hz, Sine 1500 A Forward Current 1/2 Cycle , 60Hz, Sine 1800 A TJ=45°C, t=10ms, 50Hz, Sine 11250 A2s TJ=45°C, t=8.3ms, 60Hz, Sine 16200 A2s 417 W 3000 V IF(AV) IF(RMS) IFSM Average Forward Current I2t I2t (For Fusing) PD Power Dissipation Visol Insulation Test Voltage TJ Junction Temperature -40 to +150 °C TSTG Storage Temperature Range -40 to +125 °C Torque Module-to-Sink Recommended(M4) 0.7~1.1 N·m Torque Module Electrodes Recommended(M4) 0.7~1.1 N·m RθJC Thermal Resistance Junction-to-Case 0.30 °C /W 16.5 g Weight AC, t=1min MIMMF2X100J040D ELECTRICAL CHARACTERISTICS Symbol Parameter TC=25°C unless otherwise specified Test Conditions Min. Typ. Max. Unit VR=400V -- -- 0.5 mA VR=400V, TJ=125°C -- -- 1 mA IF=100A -- 1.1 1.35 V IF=100A, TJ=125°C -- 1.0 1.25 V Reverse Leakage Current VF Forward Voltage trr Reverse Recovery Time IF=1A, VR=30V, diF/dt=-200A/μs -- 38 -- ns trr Reverse Recovery Time VR=200V, IF=100A -- 95 -- ns IRRM Max. Reverse Recovery Current diF/dt=-200A/μs, TJ=25°C -- 8.5 -- A trr Reverse Recovery Time VR=200V, IF=100A -- 150 -- ns IRRM Max. Reverse Recovery Current diF/dt=-200A/μs, TJ=125°C -- 14 -- A 300 300 250 250 200 200 TJ =125°C trr (ns) IF (A) IRM 150 VR=200V TJ =125°C 150 TJ =25°C 100 100 IF=200A 50 0 0 50 0 1 1.5 2.5 2 VF(V) Figure1. Forward Voltage Drop vs Forward Current 60 0 400 600 800 1000 diF/dt(A/μs) Figure2. Reverse Recovery Time vs diF/dt 3 VR=200V TJ =125°C 40 200 VR=200V TJ =125°C 2.5 2 30 IF=200A Qrr (μc) IRRM (A) 50 0.5 IF=100A IF=50A IF=200A IF=100A 1.5 IF=50A IF=100A 20 IF=50A 10 0 0 1 0.5 400 600 1000 800 diF/dt(A/μs) Figure3. Reverse Recovery Current vs diF/dt 200 0 0 200 400 600 800 1000 diF/dt(A/μs) Figure4. Reverse Recovery Charge vs diF/dt MIMMF2X100J040D 1.5 1 1.2 -1 10 ZthJC (K/W) Kf 0.9 trr 0.6 IRRM 0.0 10-3 Qrr 0.3 0 10-2 Duty 0.5 0.2 0.1 0.05 Single Pulse 25 50 100 125 150 75 TJ (°C) Figure5. Dynamic Parameters vs Junction Temperature -4 10 -1 10-4 10-3 10-2 10 1 Rectangular Pulse Duration (seconds) Figure6. Transient Thermal Impedance Dimensions (mm) Figure7. Package Outline