MIMMF2X100J040D

MIMMF2X100J040D
400V 100A FRED Module
RoHS Compliant
PRODUCT FEATURES
Ultrafast Reverse Recovery Time
Soft Reverse Recovery Characteristics
Low Reverse Recovery Loss
Electrically Isolated by DBC Ceramic
High System Power Density
Popular SOT-227 Package
APPLICATIONS
Inversion Welder
Uninterruptible Power Supply (UPS)
Plating Power Supply
Ultrasonic Cleaner and Welder
Converter & Chopper
Power Factor Correction (PFC) Circuit
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Values
Unit
VR
Maximum D.C. Reverse Voltage
400
V
VRRM
Maximum Repetitive Reverse Voltage
400
V
TC=90°C, Per Diode
100
A
TC=90°C, Per Moudle
200
A
TC=100°C, 20KHz, Per Moudle
150
A
RMS Forward Current
TC=90°C, Per Diode
150
A
Non-Repetitive Surge
1/2 Cycle , 50Hz, Sine
1500
A
Forward Current
1/2 Cycle , 60Hz, Sine
1800
A
TJ=45°C, t=10ms, 50Hz, Sine
11250
A2s
TJ=45°C, t=8.3ms, 60Hz, Sine
16200
A2s
417
W
3000
V
IF(AV)
IF(RMS)
IFSM
Average Forward Current
I2t
I2t (For Fusing)
PD
Power Dissipation
Visol
Insulation Test Voltage
TJ
Junction Temperature
-40 to +150
°C
TSTG
Storage Temperature Range
-40 to +125
°C
Torque
Module-to-Sink
Recommended(M4)
0.7~1.1
N·m
Torque
Module Electrodes
Recommended(M4)
0.7~1.1
N·m
RθJC
Thermal Resistance
Junction-to-Case
0.30
°C /W
16.5
g
Weight
AC, t=1min
MIMMF2X100J040D
ELECTRICAL CHARACTERISTICS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Min.
Typ.
Max.
Unit
VR=400V
--
--
0.5
mA
VR=400V, TJ=125°C
--
--
1
mA
IF=100A
--
1.1
1.35
V
IF=100A, TJ=125°C
--
1.0
1.25
V
Reverse Leakage Current
VF
Forward Voltage
trr
Reverse Recovery Time
IF=1A, VR=30V, diF/dt=-200A/μs
--
38
--
ns
trr
Reverse Recovery Time
VR=200V, IF=100A
--
95
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=25°C
--
8.5
--
A
trr
Reverse Recovery Time
VR=200V, IF=100A
--
150
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=125°C
--
14
--
A
300
300
250
250
200
200
TJ =125°C
trr (ns)
IF (A)
IRM
150
VR=200V
TJ =125°C
150
TJ =25°C
100
100 IF=200A
50
0
0
50
0
1
1.5
2.5
2
VF(V)
Figure1. Forward Voltage Drop vs Forward Current
60
0
400
600
800
1000
diF/dt(A/μs)
Figure2. Reverse Recovery Time vs diF/dt
3
VR=200V
TJ =125°C
40
200
VR=200V
TJ =125°C
2.5
2
30
IF=200A
Qrr (μc)
IRRM (A)
50
0.5
IF=100A
IF=50A
IF=200A
IF=100A
1.5
IF=50A
IF=100A
20
IF=50A
10
0
0
1
0.5
400
600
1000
800
diF/dt(A/μs)
Figure3. Reverse Recovery Current vs diF/dt
200
0
0
200
400
600
800
1000
diF/dt(A/μs)
Figure4. Reverse Recovery Charge vs diF/dt
MIMMF2X100J040D
1.5
1
1.2
-1
10
ZthJC (K/W)
Kf
0.9
trr
0.6 IRRM
0.0
10-3
Qrr
0.3
0
10-2
Duty
0.5
0.2
0.1
0.05
Single Pulse
25
50
100 125 150
75
TJ (°C)
Figure5. Dynamic Parameters vs Junction Temperature
-4
10
-1
10-4
10-3
10-2
10
1
Rectangular Pulse Duration (seconds)
Figure6. Transient Thermal Impedance
Dimensions (mm)
Figure7. Package Outline