MIMMF2X60J070D

MIMMF2X60J070D
700V 60A FRED Module
RoHS Compliant
PRODUCT FEATURES
Ultrafast Reverse Recovery Time
Soft Reverse Recovery Characteristics
Low Reverse Recovery Loss
Electrically Isolated by DBC Ceramic
High System Power Density
Popular SOT-227 Package
APPLICATIONS
Inversion Welder
Uninterruptible Power Supply (UPS)
Plating Power Supply
Ultrasonic Cleaner and Welder
Converter & Chopper
Power Factor Correction (PFC) Circuit
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Values
Unit
VR
Maximum D.C. Reverse Voltage
700
V
VRRM
Maximum Repetitive Reverse Voltage
700
V
TC=90°C, Per Diode
60
A
TC=90°C, Per Moudle
120
A
TC=90°C, 20KHz, Per Moudle
80
A
RMS Forward Current
TC=90°C, Per Diode
85
A
Non-Repetitive Surge
TJ=45°C, t=10ms, 50Hz, Sine
600
A
Forward Current
TJ=45°C, t=8.3ms, 60Hz, Sine
700
A
TJ=45°C, t=10ms, 50Hz, Sine
1800
A2s
TJ=45°C, t=8.3ms, 60Hz, Sine
2450
A2s
208
W
IF(AV)
IF(RMS)
IFSM
Average Forward Current
I2 t
I2t (For Fusing)
PD
Power Dissipation
TJ
Junction Temperature
-40 to +150
°C
TSTG
Storage Temperature Range
-40 to +125
°C
Visol
Insulation Test Voltage
AC, t=1min
3000
V
Torque
Module-to-Sink
Recommended(M4)
0.7~1.1
N·m
Torque
Module Electrodes
Recommended(M4)
0.7~1.1
N·m
RθJC
Thermal Resistance
Junction-to-Case
0.6
°C /W
26.5
g
Weight
MIMMF2X60J070D
ELECTRICAL CHARACTERISTICS
Symbol
Parameter
TC=25°C unless otherwise specified
Test Conditions
Min.
Typ.
Max.
Unit
VR=700V
--
--
1
mA
VR=700V, TJ=125°C
--
--
2
mA
IF=60A
--
1.57
2.0
V
IF=60A, TJ=125°C
--
--
1.7
V
Reverse Leakage Current
VF
Forward Voltage
trr
Reverse Recovery Time
IF=1A, VR=30V, diF/dt=-200A/μs
--
30
--
ns
trr
Reverse Recovery Time
VR=350V, IF=60A
--
70
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=25°C
--
7.1
--
A
trr
Reverse Recovery Time
VR=350V, IF=60A
--
130
--
ns
IRRM
Max. Reverse Recovery Current
diF/dt=-200A/μs, TJ=125°C
--
16
--
A
125
250
100
200
75
150
trr (ns)
IF (A)
IRM
TJ =125°C
100
50
TJ =25°C
50 IF=30A
0
1
1.5
2.5
2
VF(V)
Figure1. Forward Voltage Drop vs Forward Current
0.5
80
2
60
1.5
IF=120A
IF=60A
40
IF=30A
200
400
600
800
1000
diF/dt(A/μs)
Figure2. Reverse Recovery Time vs diF/dt
VR=350V
TJ =125°C
IF=120A
IF=60A
1
IF=30A
0.5
20
0
0
0
2.5
VR=350V
TJ =125°C
Qrr (μc)
IRRM (A)
100
IF=120A
IF=60A
25
0
0
VR=350V
TJ =125°C
400
600
1000
800
diF/dt(A/μs)
Figure3. Reverse Recovery Current vs diF/dt
200
0
0
200
400
600
800
1000
diF/dt(A/μs)
Figure4. Reverse Recovery Charge vs diF/dt
MIMMF2X60J070D
1.5
10
1.2
1
Kf
ZthJC (K/W)
0.9
0.6
trr
IRRM
0.3
0.0
10-2
Qrr
0
-1
10
25
50
100 125 150
75
TJ (°C)
Figure5. Dynamic Parameters vs Junction Temperature
Duty
0.5
0.2
0.1
0.05
Single Pulse
10-3 -4
-1
10
10-3
10-2
10
1
Rectangular Pulse Duration (seconds)
Figure6. Transient Thermal Impedance
Dimensions (mm)
Figure7. Package Outline