T551 Series 125°C

PRODUCTS
Tantalum Polymer
Through-Hole Capacitors
Electronic Components
T551 Axial Polymer Hermetic Seal (PHS) 125°C Series
Why Choose KEMET
Programs Supported
KEMET Corporation is a leading global supplier of
electronic components. We offer our customers
the broadest selection of capacitor technologies
in the industry across all dielectrics, along
with an expanding range of electromechanical
devices, electromagnetic compatibility solutions
and supercapacitors. Our vision is to be the
preferred supplier of electronic component
solutions for customers demanding the highest
standards of quality, delivery and service.
•
•
•
•
Buck/boost converters
Filtering
Hold-up capacitors
Other high ripple current applications
Dimensions
Features & Benefits • Includes F-Tech anode which eliminates
hidden defects in the dielectric
• Maximum operating temperature of +125°C
• Capacitance of 20 μF to 820 μF
• Polymer cathode technology
• ≤ 0.0075 CV (μA) at rated voltage after
5 minutes
• Extremely low ESR
• High frequency capacitance retention
• Low temperature capacitance retention
• 100% accelerated steady state aging
• 100% surge current tested
• Volumetrically efficient
• Non-ignition failure mode
• Approximately 25% lighter than equivalent
wet tantalum
• Case dimensions equivalent to
MIL-PRF-39006/22/25/30/31
Product Checklist
• What is the actual required capacitance?
• What is the operating temperature and
frequency?
• What is the operating voltage?
• Are there any voltage spikes or reverse
voltages expected?
• Are there any mechanical robustness concerns,
such as vibration or shock?
• What are the ESR requirements?
Case Code
Uninsulated Case
Inches (mm)
Case Size
MIL-PRF39006/22/25/30/31
B
Insulated Case
Inches (mm)
L
+0.031 (0.79)
-0.016 (0.41)
D
±0.016 (0.41)
0.641 (16.28)
0.281 (7.14)
T2
D
Max.
E
±0.25 (6.35)
0.312 (7.92)
*1.50 (38.10)
* Lead length of 2.25” available upon request.
Ordering Information
T
551
B
107
M
025
A
T
4251
Capacitor Class
Series
Case Size
Capacitance
Code (pF)
Capacitance
Tolerance
Voltage
Failure Rate/
Design
Lead Material
Surge Option
551 = Polymer
Hermetic Seal
B
First two digits
represent
significant
figures.
Third digit
specifies
number of
zeros.
K = ±10%
M = ±20%
T = 100% tin
(Sn) plated
4250 = Surge
current, 10 cycles
+25°C
T = Tantalum
006 = 6.3 V
008 = 8 V
015 = 15 V
025 = 25 V
040 = 40 V
050 = 50 V
060 = 60 V
A = N/A
H = Tin/lead
(SnPb) solder
coated (5% Pb
minimum)
4251 = Surge
current, 10 cycles,
-55°C and +85°C
For more information, samples
and engineering kits,
please visit us at www.kemet.com
or call 1.877.myKEMET.
SA0814
Copyright © 2014 KEMET
PRODUCTS
Tantalum Polymer
Through-Hole Capacitors
Electronic Components
T551 Axial Polymer Hermetic Seal (PHS) 125°C Series
Ratings & Part Number Reference
Rated Voltage
Rated Capacitance
Case Sizes
(V)
(μF)
6
140
B
6
820
B
8
220
8
KEMET Part Number
DC Leakage
DF
Maximum ESR
Ripple Current
μA @ 25°C
Max/5 Mins
% @ 25°C
120 Hz Max
mΩ @ 25°C
100 kHz
mArms @
85°C/40 kHz
T551B147(1)006A(2)
6.3
5.0
120
1510
T551B827(1)006A(2)
36.9
5.0
90
1750
B
T551B227(1)008A(2)
13.2
5.0
120
1510
680
B
T551B687(1)008A(2)
40.8
5.0
90
1750
10
100
B
T551B107(1)010A(2)
7.5
5.0
140
1400
10
180
B
T551B187(1)010A(2)
13.5
5.0
110
1580
10
560
B
T551B567(1)010A(2)
42.0
5.0
90
1750
15
70
B
T551B706(1)015A(2)
7.9
5.0
140
1400
15
120
B
T551B127(1)015A(2)
13.5
5.0
110
1580
15
390
B
T551B397(1)015A(2)
43.9
5.0
90
1750
25
50
B
T551B506(1)025A(2)
9.4
5.0
170
1275
25
100
B
T551B107(1)025A(2)
18.8
5.0
190
1200
30
40
B
T551B406(1)030A(2)
9.0
5.0
170
1275
30
68
B
T551B686(1)030A(2)
15.3
5.0
140
1400
40
100
B
T551B107(1)040A(2)
30.0
5.0
150
1350
40
120
B
T551B127(1)040A(2)
36.0
5.0
120
1510
50
25
B
T551B256(1)050A(2)
9.4
5.0
170
1275
50
47
B
T551B476(1)050A(2)
17.6
5.0
150
1350
50
100
B
T551B107(1)050A(2)
37.5
5.0
130
1450
50
120
B
T551B127(1)050A(2)
45.0
5.0
90
1750
60
20
B
T551B206(1)060A(2)
9.0
5.0
200
1175
60
39
B
T551B396(1)060A(2)
17.6
5.0
160
1310
60
100
B
T551B107(1)060A(2)
45.0
5.0
100
1660
(1) To complete KEMET part number, insert M for ±20% or K for ±10% for capacitance tolerance.
(2) To complete KEMET part number, insert T = 100% matte tin (Sn) plated or H = standard solder coated (SnPb 5% Pb minimum) for termination finish.
Please refer to Ordering Information for additional detail.
SA0814
Copyright © 2014 KEMET