GR500/T210 Series High Reliability

Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Overview
The solid tantalum capacitor is an essential device in circuits
requiring high capacitance voltage product and extended
environmental capability. The KEMET GR500 Graded Reliability
concept produces state-of-the-art devices, providing maximum
assurance of meeting system reliability goals. All Graded
Reliability capacitors receive meticulous attention from raw
material selection through manufacture, final inspecton and
shipping. Having survived a very stringent quality control
program, the resulting capacitors meet or exceed the most
critical requirements of space, satellite, missile and medical
applications where failure is, at best, expensive, and at worst,
fatal. KEMET is, therefore, committed to the principle of the
hightest possible reliability in the manufacture and grading of its
GR500 Series capacitors. The KEMET GR500 High Reliability
concept disallows grouping of diverse ratings and production
batches to determine average failure rates. Instead, data from
each and every capacitor batch are statistically fitted to determine
failure rate on the basis of 100% life testing. Each homogeneous
production batch is “graded” as a single inspection lot, and
documented evidence of failure rate achieved is supplied with the
parts, providing assurance of the most sophisticated and accurate
reliability measurement of method in the industry.
Benefits
Applications
• 100% Thermal Shock (-65°C to +125°C) prior to
electrical testing
• 100% Surge Current testing.
• 100% Weibull Grading
• 100% X-ray examined
• Hermeticity testing per MIL–STD–202
• Optional Special testing
• Packaged in individual container compartments
• Marking per MIL–STD–1285
• Capacitance values of 0.0047 μF to 330 μF
• Tolerances of ±5%, ±10% and ±20%
• Voltage rating of 6– 100 VDC
• Case sizes: A,B,C,D
Typical applications include coupling, bypass, filtering, and RC
timing circuits in miniaturized circuitry.
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2047_GR500_T210 • 3/9/2015
1
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Ordering Information
T
Capacitor
Class
T=
Tantalum
210
A
Series
210 = GR500/J
(KEMET) High
Reliability, Solid
Electrolyte, Graded,
Hermetic Seal, Axial
Lead, Polar
K
050
R
S
Case
Capacitance Code (pF)
Size
105
Capacitance
Tolerance
Rated Voltage
(VDC)
Failure Rate
Termination Finish
A, B,
C, D
J = ±5%
K = ±10%
M = ±20%
006 = 6.3
010 = 10
015 = 15
020 = 20
025 = 25
035 = 35
050 = 50
075 = 75
100 = 100
First two digits
represent significant
figures. Third digit
specifies number of
zeros to follow.
M = 1%/k hours
P = 0.1/k hours
R = 0.01%/k hours
S = 0.001%/k hours
S = Standard
(Solder-coated nickel)
Performance Characteristics
Item
Performance Characteristics
Operating Temperature
Rated Capacitance Range
Capacitance Tolerance
Rated Voltage Range
-55°C to 125°C
0.0047 – 330 μF at 120 Hz/25°C
J Tolerance (5%), K Tolerance (10%), M Tolerance (20%)
6 – 100 V
DF (120 Hz at 25°C)
Refer to Part Number Electrical Specification Table
ESR and Impedance (100 kHz at 25°C)
Refer to Part Number Electrical Specification Table
Leakage Current
Failure Rate
Refer to Part Number Electrical Specification Table (at rated voltage up to +85°C and 2/3 of rated
voltage applied at 125°C)
M - 1%/k hours, P - 0.1%/k hours, R - 0.01%/k hours, S - 0.001%/k hours
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2047_GR500_T210 • 3/9/2015
2
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Dimensions – Millimeters (Inches)
Metric will govern
Case
Size
Uninsulated
Insulated
D ±0.005 L ±0.031 D ±0.010 L ±0.031 B ±0.002
C
±(.13)
±(.79)
±(.25)
±(.79)
±(.05) Maximum
A
0.125 (3.18)
B
0.175 (4.45) 0.438 (11.13) 0.185 (4.70) 0.474 (12.04) 0.020 (0.51) 0.610 (15.49)
C
0.279 (7.09) 0.650 (16.51) 0.289 (7.34) 0.686 (17.42) 0.025 (0.64) 0.822 (20.88)
D
0.341 (8.66) 0.750 (19.05) 0.351 (8.92) 0.786 (19.96) 0.025 (0.64) 0.922 (23.42)
0.250 (6.35) 0.135 (3.43)
0.286 (7.26)
0.020 (0.51) 0.422 (10.72)
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2047_GR500_T210 • 3/9/2015
3
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Table 1 – Ratings & Part Number Reference
Rated
Rated
Voltage Capacitance
V
µF
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
3.9
4.7
5.6
6.8
27.0
33.0
39.0
47.0
56.0
82.0
100
120
150
180
220
270
330
2.7
3.3
3.9
4.7
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
82.0
100.0
120.0
150.0
180.0
220.0
1.2
1.5
1.8
2.2
2.7
3.3
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
V
µF
Rated
Voltage
Rated
Capacitance
Case
Size
Code
A
A
A
A
B
B
B
B
B
C
C
C
C
C
D
D
D
A
A
A
A
B
B
B
B
B
B
B
C
C
C
C
C
C
D
D
D
A
A
A
A
A
A
B
B
B
B
B
B
B
B
C
C
C
C
C
C
Case
Size
Code
KEMET Part
Number
T210A395(1)006(2)S
T210A475(1)006(2)S
T210A565(1)006(2)S
T210A685(1)006(2)S
T210B276(1)006(2)S
T210B336(1)006(2)S
T210B396(1)006(2)S
T210B476(1)006(2)S
T210B566(1)006(2)S
T210C826(1)006(2)S
T210C107(1)006(2)S
T210C127(1)006(2)S
T210C157(1)006(2)S
T210C187(1)006(2)S
T210D227(1)006(2)S
T210D277(1)006(2)S
T210D337(1)006(2)S
T210A275(1)010(2)S
T210A335(1)010(2)S
T210A395(1)010(2)S
T210A475(1)010(2)S
T210B126(1)010(2)S
T210B156(1)010(2)S
T210B186(1)010(2)S
T210B226(1)010(2)S
T210B276(1)010(2)S
T210B336(1)010(2)S
T210B396(1)010(2)S
T210C476(1)010(2)S
T210C566(1)010(2)S
T210C686(1)010(2)S
T210C826(1)010(2)S
T210C107(1)010(2)S
T210C127(1)010(2)S
T210D157(1)010(2)S
T210D187(1)010(2)S
T210D227(1)010(2)S
T210A125(1)015(2)S
T210A155(1)015(2)S
T210A185(1)015(2)S
T210A225(1)015(2)S
T210A275(1)015(2)S
T210A335(1)015(2)S
T210B565(1)015(2)S
T210B685(1)015(2)S
T210B825(1)015(2)S
T210B106(1)015(2)S
T210B126(1)015(2)S
T210B156(1)015(2)S
T210B186(1)015(2)S
T210B226(1)015(2)S
T210C276(1)015(2)S
T210C336(1)015(2)S
T210C396(1)015(2)S
T210C476(1)015(2)S
T210C566(1)015(2)S
T210C686(1)015(2)S
KEMET Part
Number
Graded
Failure
Rate
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
P,R
P,R
R,S
R,S
R,S
R,S
R,S
R,S
P,R
P,R
R,S
R,S
P,R
P,R
P,R
P,R
Graded
Failure
Rate
Maximum Leakage
Current at Rated Voltage
+25ºC (µA)
+85ºC (µA)
+125ºC (µA)
0.1
0.1
0.1
0.1
0.5
0.5
0.5
0.5
0.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
3.0
0.1
0.1
0.1
0.1
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
2.0
3.0
0.25
0.25
0.25
0.25
0.25
0.25
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1.5
1.5
1.5
1.5
1.5
1.5
1.0
1.0
1.0
1.0
5.0
5.0
5.0
5.0
5.0
15.0
15.0
15.0
15.0
15.0
20.0
20.0
30.0
1.0
1.0
1.0
1.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
15.0
15.0
15.0
15.0
15.0
15.0
20.0
20.0
30.0
2.5
2.5
2.5
2.5
2.5
2.5
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
15.0
15.0
15.0
15.0
15.0
15.0
1.25
1.25
1.25
1.25
6.25
6.25
6.25
6.25
6.25
18.75
18.75
18.75
18.75
18.75
25.00
25.00
39.50
1.25
1.25
1.25
1.25
6.25
6.25
6.25
6.25
6.25
6.25
6.25
18.75
18.75
18.75
18.75
18.75
18.75
25.00
25.00
37.50
3.13
3.13
3.13
3.13
3.13
3.13
6.25
6.25
6.25
6.25
6.25
6.25
6.25
6.25
18.75
18.75
18.75
18.75
18.75
18.75
+25ºC (µA)
+85ºC (µA)
+125ºC (µA)
Maximum Leakage Current
at Rated Voltage
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
Maximum
DF (%) at
120 Hz
-55
+25ºC
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
6.0
6.0
6.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
3.0
3.0
3.0
3.0
3.0
3.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
-55
+25ºC
+85
+125ºC
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
8.0
8.0
8.0
8.0
4.0
4.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
+85
+125ºC
Maximum DF
(%) at 120 Hz
ESR Maximum
Ohms 100 kHz
+25°C
1.00
0.90
0.90
0.80
0.25
0.24
0.24
0.24
0.24
0.12
0.11
0.10
0.09
0.08
0.07
0.07
0.06
1.20
1.00
1.00
0.90
0.32
0.29
0.27
0.26
0.25
0.24
0.24
0.16
0.15
0.13
0.12
0.11
0.10
0.09
0.08
0.07
1.40
1.30
1.25
1.20
1.20
1.00
0.47
0.43
0.39
0.35
0.32
0.29
0.27
0.26
0.21
0.19
0.17
0.16
0.15
0.13
ESR Maximum
Ohms 100 kHz
+25ºC
T2047_GR500_T210 • 3/9/2015
4
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Table 1 – Ratings & Part Number Reference cont'd
Rated
Rated
Voltage Capacitance
V
µF
15
15
15
15
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
50
50
50
50
50
50
50
50
50
50
50
50
50
50
82.0
100.0
120.0
150.0
1.2
1.5
1.8
2.2
4.7
5.6
6.8
8.2
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
56.0
68.0
82.0
100
0.82
1.00
2.70
3.30
3.90
4.70
5.60
6.80
8.20
10.0
12.0
15.0
18.0
22.0
27.0
33.0
39.0
47.0
0.0047
0.0056
0.0068
0.0082
0.01
0.012
0.015
0.018
0.022
0.027
0.033
0.039
0.047
0.056
V
µF
Rated
Voltage
Rated
Capacitance
Case
Size
Code
D
D
D
D
A
A
A
A
B
B
B
B
B
B
B
C
C
C
C
C
C
D
D
D
D
A
A
B
B
B
B
B
B
C
C
C
C
C
C
D
D
D
D
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Case
Size
Code
KEMET Part
Number
T210D826(1)015(2)S
T210D107(1)015(2)S
T210D127(1)015(2)S
T210D157(1)015(2)S
T210A125(1)020(2)S
T210A155(1)020(2)S
T210A185(1)020(2)S
T210A225(1)020(2)S
T210B475(1)020(2)S
T210B565(1)020(2)S
T210B685(1)020(2)S
T210B825(1)020(2)S
T210B106(1)020(2)S
T210B126(1)020(2)S
T210B156(1)020(2)S
T210C186(1)020(2)S
T210C226(1)020(2)S
T210C276(1)020(2)S
T210C336(1)020(2)S
T210C396(1)020(2)S
T210C476(1)020(2)S
T210D566(1)020(2)S
T210D686(1)020(2)S
T210D826(1)020(2)S
T210D107(1)020(2)S
T210A824(1)035(2)S
T210A105(1)035(2)S
T210B275(1)035(2)S
T210B335(1)035(2)S
T210B395(1)035(2)S
T210B475(1)035(2)S
T210B565(1)035(2)S
T210B685(1)035(2)S
T210C825(1)035(2)S
T210C106(1)035(2)S
T210C126(1)035(2)S
T210C156(1)035(2)S
T210C186(1)035(2)S
T210C226(1)035(2)S
T210D276(1)035(2)S
T210D336(1)035(2)S
T210D396(1)035(2)S
T210D476(1)035(2)S
T210A472(1)050(2)S
T210A562(1)050(2)S
T210A682(1)050(2)S
T210A822(1)050(2)S
T210A103(1)050(2)S
T210A123(1)050(2)S
T210A153(1)050(2)S
T210A183(1)050(2)S
T210A223(1)050(2)S
T210A273(1)050(2)S
T210A333(1)050(2)S
T210A393(1)050(2)S
T210A473(1)050(2)S
T210A563(1)050(2)S
KEMET Part
Number
Graded
Failure
Rate
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
R,S
P,R
P,R
P,R
P,R
P,R
P,R
R,S
R,S
P,R
P,R
P,R
P,R
M,P
M,P
M,P
M,P
R,S
R,S
R,S
R,S
R,S
R,S
M,P
M,P
R,S
R,S
P,R
P,R
P,R
M,P
M,P
M,P
M,P
M,P
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
Graded
Failure
Rate
Maximum Leakage
Current at Rated Voltage
+25ºC (µA)
+85ºC (µA)
+125ºC (µA)
2.0
2.0
2.0
3.0
0.25
0.25
0.25
0.25
0.5
0.5
0.5
0.5
0.5
0.5
0.5
1.0
1.0
1.5
1.5
1.5
1.5
2.0
2.0
3.0
3.0
0.1
0.1
0.25
0.5
0.5
0.5
0.5
0.5
1.0
1.0
1.0
1.0
1.0
1.0
2.0
2.0
2.0
3.0
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
20.0
20.0
20.0
30.0
2.5
2.5
2.5
2.5
5.0
5.0
5.0
5.0
5.0
5.0
5.0
10.0
10.0
15.0
15.0
15.0
15.0
20.0
20.0
30.0
30.0
1.0
1.0
2.5
5.0
5.0
5.0
5.0
5.0
10.0
10.0
10.0
10.0
10.0
10.0
20.0
20.0
20.0
30.0
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
25.00
25.00
25.00
37.50
3.13
3.13
3.13
3.13
6.25
6.25
6.25
6.25
6.25
6.25
6.25
12.50
12.50
18.75
18.75
18.75
18.75
25.00
25.00
37.50
37.50
1.25
1.25
3.13
6.25
6.25
6.25
6.25
6.25
12.50
12.50
12.50
12.50
12.50
12.50
25.00
25.00
25.00
37.50
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
0.63
+25ºC (µA)
+85ºC (µA)
+125ºC (µA)
Maximum Leakage Current
at Rated Voltage
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
Maximum
DF (%) at
120 Hz
-55
+25ºC
5.0
5.0
5.0
5.0
3.0
3.0
3.0
3.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
2.0
2.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
4.0
4.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
-55
+25ºC
+85
+125ºC
8.0
8.0
8.0
8.0
4.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
6.0
6.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
+85
+125ºC
Maximum DF
(%) at 120 Hz
ESR Maximum
Ohms 100 kHz
+25°C
0.11
0.10
0.09
0.09
1.40
1.30
1.25
1.20
0.51
0.47
0.43
0.39
0.35
0.32
0.29
0.25
0.25
0.21
0.19
0.17
0.16
0.13
0.12
0.11
0.10
1.60
1.40
0.68
0.62
0.56
0.51
0.47
0.43
0.36
0.33
0.30
0.27
0.25
0.25
0.18
0.17
0.15
0.14
30.00
28.00
26.00
24.00
22.00
20.00
18.00
16.00
14.00
13.00
12.00
11.00
10.00
9.00
ESR Maximum
Ohms 100 kHz
+25ºC
T2047_GR500_T210 • 3/9/2015
5
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Table 1 – Ratings & Part Number Reference cont'd
Rated
Rated
Voltage Capacitance
V
µF
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
75
0.068
0.082
0.1
0.12
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.56
0.68
0.82
1.00
1.20
1.50
1.80
2.20
2.70
3.30
3.90
4.70
5.60
6.80
8.20
10.0
12.0
15.0
18.0
22.0
0.0047
0.0056
0.0068
0.0082
0.01
0.012
0.015
0.018
0.022
0.027
0.033
0.039
0.047
0.056
0.068
0.082
0.1
0.12
0.15
0.18
0.22
0.27
0.33
0.39
0.47
V
µF
Rated
Voltage
Rated
Capacitance
Case
Size
Code
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
C
C
C
C
C
C
C
D
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
Case
Size
Code
KEMET Part
Number
T210A683(1)050(2)S
T210A823(1)050(2)S
T210A104(1)050(2)S
T210A124(1)050(2)S
T210A154(1)050(2)S
T210A184(1)050(2)S
T210A224(1)050(2)S
T210A274(1)050(2)S
T210A334(1)050(2)S
T210A394(1)050(2)S
T210A474(1)050(2)S
T210A564(1)050(2)S
T210A684(1)050(2)S
T210A824(1)050(2)S
T210A105(1)050(2)S
T210B125(1)050(2)S
T210B155(1)050(2)S
T210B185(1)050(2)S
T210B225(1)050(2)S
T210B275(1)050(2)S
T210B335(1)050(2)S
T210B395(1)050(2)S
T210B475(1)050(2)S
T210C565(1)050(2)S
T210C685(1)050(2)S
T210C825(1)050(2)S
T210C106(1)050(2)S
T210C126(1)050(2)S
T210C156(1)050(2)S
T210C186(1)050(2)S
T210D226(1)050(2)S
T210A472(1)075(2)S
T210A562(1)075(2)S
T210A682(1)075(2)S
T210A822(1)075(2)S
T210A103(1)075(2)S
T210A123(1)075(2)S
T210A153(1)075(2)S
T210A183(1)075(2)S
T210A223(1)075(2)S
T210A273(1)075(2)S
T210A333(1)075(2)S
T210A393(1)075(2)S
T210A473(1)075(2)S
T210A563(1)075(2)S
T210A683(1)075(2)S
T210A823(1)075(2)S
T210A104(1)075(2)S
T210A124(1)075(2)S
T210A154(1)075(2)S
T210A184(1)075(2)S
T210A224(1)075(2)S
T210A274(1)075(2)S
T310A334(1)075(2)S
T310A394(1)075(2)S
T210A474(1)075(2)S
KEMET Part
Number
Graded
Failure
Rate
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
R,S
P,R
P,R
R,S
R,S
R,S
R,S
P,R
P,R
P,R
M,P
P,R
P,R
P,R
P,R
M,P
M,P
M,P
M,P
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
P,R
Graded
Failure
Rate
Maximum Leakage
Current at Rated Voltage
+25ºC (µA)
+85ºC (µA)
+125ºC (µA)
0.05
0.05
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.25
0.25
0.25
0.25
0.25
0.5
0.5
0.5
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.0
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.5
0.5
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.5
2.5
2.5
2.5
2.5
5.0
5.0
5.0
15.0
15.0
15.0
15.0
15.0
15.0
15.0
20.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
0.63
0.63
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
3.13
3.13
3.13
3.13
3.13
6.25
6.25
6.25
18.75
18.75
18.75
18.75
18.75
18.75
18.75
25.00
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
+25ºC (µA)
+85ºC (µA)
+125ºC (µA)
Maximum Leakage Current
at Rated Voltage
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
Maximum
DF (%) at
120 Hz
-55
+25ºC
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
-55
+25ºC
+85
+125ºC
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
+85
+125ºC
Maximum DF
(%) at 120 Hz
ESR Maximum
Ohms 100 kHz
+25°C
8.00
7.50
7.00
6.50
5.50
5.00
4.00
3.50
3.30
3.30
3.00
2.50
1.80
1.60
1.40
1.20
1.10
0.92
0.80
0.68
0.62
0.56
0.51
0.44
0.40
0.36
0.33
0.30
0.27
0.25
0.20
30.00
28.00
26.00
24.00
22.00
20.00
18.00
16.00
14.00
13.00
12.00
11.00
10.00
9.00
8.00
7.50
7.00
6.50
4.40
4.00
3.50
3.10
2.80
2.60
2.40
ESR Maximum
Ohms 100 kHz
+25ºC
T2047_GR500_T210 • 3/9/2015
6
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Table 1 – Ratings & Part Number Reference cont'd
Rated
Rated
Voltage Capacitance
V
µF
75
75
75
75
75
75
75
75
75
75
75
75
75
75
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
100
0.56
0.68
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10.0
12.0
15.0
0.0047
0.0056
0.0068
0.0082
0.01
0.012
0.015
0.018
0.022
0.027
0.033
0.039
0.047
0.056
0.068
0.082
0.1
0.12
0.15
0.18
0.22
0.27
0.33
0.39
0.47
0.56
0.68
0.82
1
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10.0
V
µF
Rated
Voltage
Rated
Capacitance
Case
Size
Code
A
A
B
B
B
B
B
C
C
C
C
C
D
D
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
B
B
B
B
B
B
B
B
C
C
C
C
C
D
D
Case
Size
Code
KEMET Part
Number
T210A564(1)075(2)S
T210A684(1)075(2)S
T210B185(1)075(2)S
T210B225(1)075(2)S
T210B275(1)075(2)S
T210B335(1)075(2)S
T210B395(1)075(2)S
T210C475(1)075(2)S
T210C565(1)075(2)S
T210C685(1)075(2)S
T210C825(1)075(2)S
T210C106(1)075(2)S
T210D126(1)075(2)S
T210D156(1)075(2)S
T210A472(1)100(2)S
T210A562(1)100(2)S
T210A682(1)100(2)S
T210A822(1)100(2)S
T210A103(1)100(2)S
T210A123(1)100(2)S
T210A153(1)100(2)S
T210A183(1)100(2)S
T210A223(1)100(2)S
T210A273(1)100(2)S
T210A333(1)100(2)S
T210A393(1)100(2)S
T210A473(1)100(2)S
T210A563(1)100(2)S
T210A683(1)100(2)S
T210A823(1)100(2)S
T210A104(1)100(2)S
T210A124(1)100(2)S
T210A154(1)100(2)S
T210A184(1)100(2)S
T210A224(1)100(2)S
T2l0A274(1)100(2)S
T210A334(1)100(2)S
T210A394(1)100(2)S
T210A474(1)100(2)S
T210A564(1)100(2)S
T210B684(1)100(2)S
T210B824(1)100(2)S
T210B105(1)100(2)S
T210B125(1)100(2)S
T210B155(1)100(2)S
T210B185(1)100(2)S
T210B225(1)100(2)S
T210B275(1)100(2)S
T210C335(1)100(2)S
T210C395(1)100(2)S
T210C475(1)100(2)S
T210C565(1)100(2)S
T210C685(1)100(2)S
T210D825(1)100(2)S
T210D106(1)100(2)S
KEMET Part
Number
Graded
Failure
Rate
P,R
M,P
P,R
P,R
M,P
M,P
M,P
P,R
P,R
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M.P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M,P
M
M
M
Graded
Failure
Rate
Maximum Leakage
Current at Rated Voltage
+25ºC (µA)
+85ºC (µA)
+125ºC (µA)
0.25
0.25
0.5
0.5
0.5
0.75
0.75
1.5
1.5
2.0
2.0
2.0
2.5
2.5
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.25
0.5
0.5
0.5
0.5
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5
5.0
5.0
5.0
7.5
7.5
15.0
15.0
20.0
20.0
20.0
25.0
25.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
5.0
5.0
5.0
5.0
20.0
20.0
20.0
20.0
20.0
25.0
25.0
3.13
3.13
6.25
6.25
6.25
9.40
9.40
18.75
18.75
25.00
25.00
25.00
31.25
31.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
1.25
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
3.13
6.25
6.25
6.25
6.25
25.00
25.00
25.00
25.00
25.00
31.25
31.25
+25ºC (µA)
+85ºC (µA)
+125ºC (µA)
Maximum Leakage Current
at Rated Voltage
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
Maximum
DF (%) at
120 Hz
-55
+25ºC
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
-55
+25ºC
+85
+125ºC
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
+85
+125ºC
Maximum DF
(%) at 120 Hz
ESR Maximum
Ohms 100 kHz
+25°C
2.25
2.10
0.92
0.80
0.68
0.62
0.56
0.47
0.44
0.44
0.36
0.33
0.26
0.23
30.00
28.00
26.00
24.00
22.00
20.00
18.00
16.00
14.00
13.00
12.00
11.00
10.00
9.00
8.00
7.50
7.00
6.50
4.40
4.00
3.50
3.10
2.80
2.60
2.40
2.25
2.10
1.47
1.40
1.33
1.06
0.92
0.80
0.68
0.62
0.56
0.47
0.44
0.40
0.36
0.33
ESR Maximum
Ohms 100 kHz
+25ºC
T2047_GR500_T210 • 3/9/2015
7
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Ripple Current/Ripple Voltage
Permissible AC ripple voltage is related to the ESR of the capacitor and the power dissipation capabilities of a particular case size.
Thermal capacities for the various case sizes have been determined empirically and are listed below.
Temperature Compensation Multipliers
for Maximum Power Dissipation
T ≤ 25°C
1.00
T ≤ 85°C
0.90
T ≤ 125°C
0.40
T= Environmental Temperature
Permissible AC ripple current can be determined by the following:
I(max) = Z √P max/R
Case Size
Maximum Power
Dissipation (P max)
T2XX
A
0.09
0.070
B
0.100
0.090
C
0.125
–
D
0.180
–
Maximum Power Dissipation: 25°C Ambient
P max = maximum watts
R = ESR at specified frequency (ohms)
I = rms ripple current (amperes)
Z = capacitor impedance in ohms at the specified frequency
Optimum Solder Wave Profile
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2047_GR500_T210 • 3/9/2015
8
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Mounting
All encased capacitors will pass the Resistance to Soldering Heat Test of MIL–STD–202, Method 210, Condition C. This test simulates
wave solder of topside board mount product. This demonstration of resistance to solder heat is in accordance with what is believed to
be the industry standard. More severe treatment must be considered reflective of an improper soldering process. The above figure is a
recommended solder wave profile for both axial and radial leaded solid tantalum capacitors.
Capacitor Marking
GR500/T210
Case A
Case B
Polarity Symbol,
Series designator
+T 210
K 10% S
R68 µF
50V
330 AA
K = KEMET, Tolerance
& Failure rate
Capacitance
Voltage
Date Code &
Batch designator
+K T210 B
475K050
SS4R7 µF
50V 10%
1330 AA
Polarity, KEMET, Series
designator, case size
KEMET Part Number
KEMET Part Number
(continued)
Voltage, Tolerance
Date Code &
Lot Symbol
Case C & D
Date Code *
1st digit = Last number of Year
2 = 2012
3 = 2013
4 = 2014
2nd and 3rd digit = Week of the Year
01 = 1st week of the Year to
52 = 52nd week of the Year
+ KEMET
T210C106K
035SS 10%
10µF 35V
1330 AA
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
Polarity Symbol, KEMET
KEMET Part Number
KEMET Part Number
(continued)
Capacitance, Voltage
Date Code &
Lot Symbol
T2047_GR500_T210 • 3/9/2015
9
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Storage
Tantalum hermetically sealed capacitors should be stored in normal working environments. While the capacitors themselves are quite
robust in other environments, solderability will be degraded by exposure to high temperatures, high humidity, corrosive atmospheres,
and long term storage. In addition, packaging materials will be degraded by high temperature– reels may soften or warp and tape peel
force may increase. KEMET recommends that maximum storage temperature not exceed 40ºC and maximum storage humidity not
exceed 60% relative humidity. Temperature fluctuations should be minimized to avoid condensation on the parts and atmospheres
should be free of chlorine and sulphur bearing compounds. For optimized solderability capacitors stock should be used promptly,
preferably within three years of receipt.
Packaging
Capacitors shall be packaged in individual container compartments. Packaging methods and materials used shall prevent degradation
of capacitor characteristics as determined by this specification.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2047_GR500_T210 • 3/9/2015
10
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
KEMET Corporation
World Headquarters
Europe
Asia
Southern Europe
Sasso Marconi, Italy
Tel: 39-051-939111
Northeast Asia
Hong Kong
Tel: 852-2305-1168
Mailing Address:
P.O. Box 5928
Greenville, SC 29606
Skopje, Macedonia
Tel: 389-2-55-14-623
Shenzhen, China
Tel: 86-755-2518-1306
www.kemet.com
Tel: 864-963-6300
Fax:864-963-6521
Central Europe
Landsberg, Germany
Tel: 49-8191-3350800
Corporate Offices
FortLauderdale,FL
Tel: 954-766-2800
Kamen, Germany
Tel: 49-2307-438110
North America
Northern Europe
Harlow, United Kingdom
Tel: 44-1279-460122
Taipei, Taiwan
Tel: 886-2-27528585
Espoo,Finland
Tel: 358-9-5406-5000
Southeast Asia
Singapore
Tel: 65-6701-8033
2835 KEMET Way
Simpsonville, SC 29681
Southeast
LakeMary,FL
Tel: 407-855-8886
Northeast
Wilmington, MA
Tel: 978-658-1663
Central
Novi, MI
Tel: 248-306-9353
Beijing, China
Tel: 86-10-5877-1075
Shanghai, China
Tel: 86-21-6447-0707
Seoul, South Korea
Tel: 82-2-6294-0550
Penang, Malaysia
Tel: 60-4-6430200
Bangalore, India
Tel: 91-806-53-76817
West
Milpitas, CA
Tel: 408-433-9950
Mexico
Guadalajara, Jalisco
Tel: 52-33-3123-2141
Note: KEMET reserves the right to modify minor details of internal and external construction at any time in the interest of product improvement. KEMET does not
assume any responsibility for infringement that might result from the use of KEMET Capacitors in potential circuit designs. KEMET is a registered trademark of
KEMET Electronics Corporation.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2047_GR500_T210 • 3/9/2015
11
Tantalum Through-Hole Capacitors – Hermetically Sealed
GR500/T210 Series High Reliability
Disclaimer
Allproductspecifications,statements,informationanddata(collectively,the“Information”)inthisdatasheetaresubjecttochange.Thecustomerisresponsibleforcheckingand
verifying the extent to which the Information contained in this publication is applicable to an order at the time the order is placed.
All Information given herein is believed to be accurate and reliable, but it is presented without guarantee, warranty, or responsibility of any kind, expressed or implied.
Statements of suitability for certain applications are based on KEMET Electronics Corporation’s (“KEMET”) knowledge of typical operating conditions for such applications, but are
notintendedtoconstitute–andKEMETspecificallydisclaims–anywarrantyconcerningsuitabilityforaspecificcustomerapplicationoruse.TheInformationisintendedforuseonly
by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by KEMET with reference to the use of KEMET’s products is given gratis, and KEMET assumes no obligation or liability for the advice given or results obtained.
Although KEMET designs and manufactures its products to the most stringent quality and safety standards, given the current state of the art, isolated component failures may still
occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable designs or other safeguards (such as installation of protective
circuitry or redundancies) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or property damage.
Although all product–related warnings, cautions and notes must be observed, the customer should not assume that all safety measures are indicted or that other measures may not
be required.
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2047_GR500_T210 • 3/9/2015
12