Electrical contacts CES-CESA-CEI / Amplifier relay AREB-AYRA

Electrical contacts CES-CESA-CEI / Amplifier relay AREB-AYRA
General
Electrical contacts can be fitted to our instruments with nominal diameters 100, 150, 160 mm.
They are adjustable from 10% to 90% of F.S.
The overall dimensions, mounting and switching arrangements, operating limits (pressure and temperature) are all given in the corresponding documentation
for each series of equipment.
Various contact models :
- dry contact
- dry contact with magnet
- inductive contact
: CES (40xx)
: CES A (50xx)
: CEI (80xx)
Various amplifier models
- multifunction relay
- Intrinsically safe relay
: AREB
: AYRA
Specifications
Contact material :
During their use, electrical contacts are subjected to a varying degree of wear, depending on their operating conditions, under the effect of mechanical stresses, the effect of electrical arc and heating.
The choice of material for contacts must allow for the specific operating conditions.
Standard material is a Ag 80-Ni 20 alloy. It has a high resistance to the electric arc effect (sparking).
Oil filled version (not available for differential pressure gauges) :
When a gauge is to be oil filled, CES A or CEI contacts must be used. The gauge must be filled with silicon oil (BH3). The power switching capacity is
significantly reduced. It is then necessary to use a relay.
CAUTION :
For use with OXYGEN, use filling fluid BH5 (not available for differential pressure gauges).
1 contact
(4001) (5001) (8001)
2 Min
(4002) (5002) (8002)
2 contacts
Two wire supply
1 Max
CES
Contact open
above the
set point
Inter
Index
Closed
Contact closed inside
area determined by
the 2 set points open
outside
Inter
Index
Opendes
Contact open inside
area determined by
the 2 set points closed
outside
CESA
21
Min-Max
Contact closed
above the
set point
(4021)
(5021)
22
Min-Min
2 contacts
CEI
Three wire supply CES-CESA
CESA
Four wire supply CEI
CES
Contact block
control function
CES - CESA - CEI
(4022)
(5022)
11
Max-Max
(4011)
(5011)
12
Max-Min
(4012)
(5012)
Contact block
control function
CES - CESA - CEI
First contact open
second contact
closed above
the set point
First and second
contacts open above the
set point
First and second contacts
closed above the
set point
First contact closed
second contact
open above
the set point
very thick black sector : closed contact
very fine sector : open contact
www.baumer.com/process
Design and specifications subject to change without notice
Data Sheet A21.33
Page 1
Dry electrical contacts CES
Applications
These contacts are used when normal service conditions require a low switching power.
This type of contacts requires vibration-free installation and cannot be used with liquid filled gauges.
In aggressive environments use CEI inductive contacts + AREB amplifier relay.
Dry electrical contacts with magnets CES A
Applications
These contacts are used in practically all service conditions. They are, to a very great extent, insensitive to vibrations. They can be used with liquid
filled instruments.
Technical characteristics CES-CES A
Recommended power ratings for resistive and inductive loads under mormal use.
Magnetic contact CES A
Contact CES
inductive
inductive
Resistive load
Resistive load
load
load
Voltage
dc V
ac V
dc mA
ac mA
220
110
48
24
230
110
48
24
40
80
120
200
45
90
170
350
ac
cos >0.7
mA
25
45
70
100
ac
cos>0.7
mA
dc mA
ac mA
100
200
300
400
120
240
450
600
65
130
200
250
Load limits for resistive and inductive loads under mormal use.
Magnetic contact CES A
Contact CES
61 – 300 V
61 – 300 V
Nominal insulation voltage U l
Nominal service voltage Ueff max
250 V
250 V
Nominal service current :
Circuit closing current
Circuit opening current
Permanent current
load
0.7A
0.7A
0.6A
1.0A
1.0A
0.6A
10W 18VA
30W 50VA
Switching power
Minimum power values for contacts - resistive and inductive loads under mormal use.
Contact CES
24V
Nominal service voltage Ueff max
Magnetic contact CES A
24V (*12V)
0.4W 0.4VA
0.4W 0.4VA
Switching power
* Gold contact version
NOTE: As a general rule we recommend that the use of a relay type AREB, and for gauges filled with liquid and magnetic
contacts, it is essential to use a relay.
Cable identification
1 MAXI
2
1 5
11 MAXI MAXI
2
3
3 SPDT
2 MINI
1 5
2
2
1 5
12 MAXI MINI
2
3
1 5
1
INVERSEUR
3
3
5
21 MINI MAXI
2
www.baumer.com/process
Design and specifications subject to change without notice
3
1 5
INTER INDEX
1 5
2
3
22 MINI MINI
2
3
5
45
6
3 2
1
1 5
Data Sheet A21.33
Page 2
Inductive electrical contacts CEI
Applications in none hazardous area
CEI contacts are used in a highly vibrating environment. They are spark, overheating or wear proof.
They must be used with a AREB amplifier relay (intrinsic safety).
Applications in hazardous area (ATEX)
CEI contacts are used in explosive atmosphere and hazardous area. They are spark, overheating or wear proof.
They must be used with a AYRA amplifier relay.
Glass window
LCIE 03 ATEX 6402X
CE 0081
II 2 G
Ex ia IIC T6 or T5 or T4
Pressure gauge / Thermometers
Relay - Amplifier - Barrier
No hazardous area
Hazardous area 1 and 2
Polycarbonate window
power supply
LCIE 03 ATEX 6402X
CE 0081
out put
II 2 G
Ex ia IIA T6 or T5 or T4
For an intrinsically safe installation it is important that
only certified accessories are used
Technical characteristics
For each inductive independant contact : U nominal 8 Vdc - Current consumption ≥ 3 mA - Ci = 30 nF, Li = 100 uH
This equipment must only be associated to IS certified apparatus, and this combination must be compatible as regards intrinsic safety.
In order to ensure temperature classification and keep safety, the power supply linear characteristics should not exceed none of the following values
for each inductive contact :
Power supply A
Power supply B
Power supply C
Power supply D
Ui ≤ 16 V
Ui ≤ 16 V
Ui ≤ 16 V
Ui ≤ 16 V
Ii ≤ 25 mA
Ii ≤ 25 mA
Ii ≤ 52 mA
Ii ≤ 76 mA
Pi ≤ 34 mW
Pi ≤ 64 mW
Pi ≤ 169 mW
Pi ≤ 242 mW
Temperature classification
T6
T6
T5
T6
T5
T4
T6
T5
T4
Temperature classification
SJ2N
-20°C ≤
≤ +70°C
-20°C ≤
≤ +67°C
-20°C ≤
≤ +70°C
-20°C ≤
≤ +45°C
-20°C ≤
≤ +60°C
-20°C ≤
≤ +70°C
-20°C ≤
≤ +30°C
-20°C ≤
≤ +45°C
-20°C ≤
≤ +57°C
SJ2SN
-40°C ≤
≤ +70°C
-40°C ≤
≤ +66°C
-40°C ≤
≤ +70°C
-40°C ≤
≤ +45°C
-40°C ≤
≤ +60°C
-40°C ≤
≤ +70°C
-40°C ≤
≤ +30°C
-40°C ≤
≤ +45°C
-40°C ≤
≤ +57°C
All necessary measures must be taken by the user, to avoid the calorific transfer from the fluid to the apparatus head increasing the head's temperature to such that it
reaches the self-ignition temperature of the gas in which it is used.
Cable identification
2 Mini
1 Maxi
2
1
21
1
2
12
21 Mini/Maxi
22 Mini/Mini
111 Maxi/Maxi/Maxi
112 Maxi/Maxi/Mini
14
32
211 Mini/Maxi/Maxi
13
42
212 Mini/Maxi/Mini
246 531
221 Mini/Mini/Maxi
245 631
222 Mini/Mini/Mini
146 532
145 632
www.baumer.com/process
Design and specifications subject to change without notice
136 542
135 642
11 Maxi/Maxi
12 Maxi/Mini
24
31
121 Maxi/Mini/Maxi
23
41
122 Maxi/Mini/Mini
235 641
236 541
45
6
3 2
1
1:2:+
contact 1
3:4:+
contact 2
5:6:+
contact 3
Data Sheet A21.33
Page 3
Electrical connector
Item
Junction box
Connector Connector thread1)
Connection illustration
Position of connector
left side
right side
back
left side
back
left side
back
Number of pins in electrical
connector
6
6
6
7
7
7
7
Cable gland
M20 x 1.5
M20 x 1.5
M20 x 1.5
M20 x 1.5
M20 x 1.5
Pg 11
Pg 11
Wire cross-section
max. 2.5
max. 2.5
max. 2.5
max. 2.5
max. 2.5
max. 2.5
max. 2.5
Degree of protection (EN 60 529)
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
IP 65
Code
4710
4711
4715
4712
4716
4726
4721
Standard
Option
Option
Option
Option
Option
Option
www.baumer.com/process
Design and specifications subject to change without notice
Data Sheet A21.33
Page 4
Multifunction Amplifier Relay
- Not for ATEX use
Specifications
Case
Output Polyamide 6.6
Overall dimensions - mounting : see below.
Power supply
Standard : 230 Vac
50-60 Hz
+ 6%
Options : 115 Vac - 10% 40-60 Hz
24 Vcc + 6%
- 10%
Consumption
2.5 VA
Reversing contact relay; rupturing capacity
Max. 8A - 250 V - 2000 VA
Mini. 0,1A - 24 Vcc
Operating temperature
0 ... 70° C
Protection
IP 20
Relay dimensions AREB (24 Vcc - 110 Vac - 220 Vac)
Attachment : on rail DIN 50022 or by 2 screws
AREB 1 treshold 250g
AREB 2 tresholds 280g
Ordering details - relay
Family
Accessories
Relay
MSR
1´ digit
AREBxDx
A
2´...4´ digit
REB
Power supply
Standard 220 Vac
Option 110 Vac
Option
24 Vcc
5´ digit
Attachment on rail DIN
Montage sur rail DIN
6´ digit
D
Control functions
1 treshold
2 tresholds
7´ digit
1
2
A
D
F
www.baumer.com/process
Design and specifications subject to change without notice
Data Sheet A21.33
Page 5
Intrinsically Safe Amplifier Relay
- For ATEX use
Specifications
Control circuit
CE 0102
Case
II (1) GD
Ex ia IIC
Noryl auto-extinguishable
Overall dimensions - mounting : see below.
Power supply
Standard :
Options :
Consumption
220 Vac ± 15%, 45-60 Hz
110 Vac ± 15%, 40-60 Hz
24 Vcc
Output Reversing contact relay; rupturing capacity
4A - 250 V - 500 VA
Operating temperature
-20 ... 60° C
Protection
IP 30.
Max. RSI pressure gauge distance : 3000 m.
(Max. R in line 100 Ω).
1.5 VA
Relay dimensions AYRA (220 Vac-110 Vac)
Attachment : on rail DIN 50022 or by 2 screws
390 g
410 g
CE certificate N° PTB 02 ATEX 2065
Relay dimensions AYRA (24 Vcc)
1 contact
2 contacts
DIN-rail mounting
DIN-rail mounting
150 g
DIN-rail mounting
DIN-rail mounting
Attachment : on rail DIN 50022
300 g
CE certificate N° PTB 00 ATEX 2080
Relay codification
Family
Accessories
Relay
RSI (intrinsically safe)
1´ digit
AYRAxDx
A
2´...4´ digit
YRA
Power supply
Standard 220 Vac
Option 110 Vac
Option
24 Vcc
5´ digit
Attachment on rail DIN
Attachment on rail Din
6´ digit
D
Control functions
1 treshold
2 tresholds
7´ digit
1
2
A
D
F
www.baumer.com/process
Design and specifications subject to change without notice
Data Sheet A21.33
Page 6
UK/11-2008 This data sheet may only be reproduced in full
2 contacts
1 contact