Architectural Lighting Debuzzing Chokes

Electromagnetic Integrated Solutions
8061 Avonia Road, Fairview, PA 16415
P: +1 (814) 474 1571
E: [email protected]
http://eis.apitech.com
Architectural Lighting Debuzzing Chokes
P/N Lamp I Voltage (Amps) LOAD (Watts TR (µS) Vd (Volts) Tr (°C) DCR (OHMS) L (mH) WIRE GA. FIG. 12
4.167
50
500
.625
69
.11
1.38
19
1
120
4.167
500
67
.458
69
.11
1.38
19
1
12
4.167
50
1060
.798
56
.14
1.51
18
2
120
4.167
500
157
.601
56
.14
1.51
18
2
12
4.167
50
1070
.588
44
.11
1.15
17
3
120
4.167
500
128
.473
44
.11
1.15
17
3
12
6.25
75
1070
.972
75
.11
1.15
17
3
120
6.25
750
134
.719
75
.11
1.15
17
3
12
4.167
50
1100
.732
52
.14
1.25
18
3
120
4.167
500
134
.597
52
.14
1.25
18
3
12
4.167
50
1250
.828
57
.14
1.56
18
3
120
4.167
500
156
.617
57
.14
1.56
18
3
12
4.167
50
1300
.669
43
.12
1.33
17
3
120
4.167
500
154
.514
43
.12
1.33
17
3
12
6.25
75
1300
1.12
74
.12
1.33
17
3
120
6.25
750
161
.785
74
.12
1.33
17
3
101425-119091
1328-118100
161859-117120
161859-118125
1618-118127
162359-117115
Explanation of the Terms
I = Load current
TR = Time taken for current to rise from 10% to 90% of its peak value
This factor and the rate of current rise (slew rate) * determine the amount of noise reduction in the lamp.
Vd = Voltage drop due to choke. (See circuits 1 and 2)
Tr = Approximate temperature rise. (Convection cooled)
+15
L = Low level inductance
-7.5%
Electromagnetic Integrated Solutions
8061 Avonia Road, Fairview, PA 16415
P: +1 (814) 474 1571
E: [email protected]
http://eis.apitech.com
Mechanical Drawing
DIM:
Inches
mm
Terminology
Vp = Primary side of transformer T-1
Vs = Secondary (Low voltage side) of transformer T-1
VL = Voltage seem at the load (Lamps)
Vd = Voltage drop due to choke (Vd = Vs – VL)
L1.L2.L3.L4, etc. + Debuzzing chokes. May or may not be the same type. **
*Foot mounting may be cut off at factory or in the field and the center mounting hole be used only.