CPI Canada Inc X-Ray Tube Stator Compatibility Tables SUPPLEMENT X-RAY TUBE STATOR COMPATIBILITY TABLES CONTENTS: 1.0 2.0 3.0 3.1 INTRODUCTION ............................................................................................................................................. 2 LOW SPEED STARTER TUBE SELECT TABLE ............................................................................................ 2 DUAL SPEED STARTER TUBE SELECT TABLE......................................................................................... 18 DUAL SPEED STARTER (AND INDICO IQ LOW SPEED STARTER) TUBE CODES................................... 38 PROPRIETARY AND CONFIDENTIAL The design and information contained in this document is proprietary to Communications & Power Industries Canada Inc. (CPI), has been designed and developed at private expense, and is the exclusive property of CPI. The information contained herein is loaned in confidence solely for the installation, operation, and maintenance of CPI equipment. This document may not be duplicated in whole or in part, or be used for re-engineering, reverse engineering, or otherwise reproducing in any form or creating or attempting to create or permitting, allowing or assisting others to create or manufacture CPI’s product or products derived there from, without the express written permission of CPI. Copyright © by Communications & Power Industries Canada Inc. All rights reserved. Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 1 X-Ray Tube Stator Compatibility Tables 1.0 CPI Canada Inc INTRODUCTION This supplement contains the X-Ray Tube Stator Compatibility Tables for the Low Speed Starter (LSS) and the Dual Speed Starter (DSS). 2.0 LOW SPEED STARTER TUBE SELECT TABLE Indico IQ Generators Only The Low Speed Starter (LSS) synthesizes its output frequencies independently of the line frequency and will operate most tubes at 60 Hz, as indicated in Table 1. Unless indicated otherwise within Table 1, setting the switches to the code indicated for the applicable Tube Type selects all required operating parameters. The Low Speed Starter part number corresponds to the configuration of phase-shift capacitors installed. Reference notes are provided at the end of Table 1. Tube operating parameters for each switch code are contained in Table 3 for reference. Indico 100 Generators Only The boost voltage may be set to either 240 VAC (factory default) or 120 VAC. This should be set to 240 VAC, except where specifically noted in Table 1 below. The Low Speed Starter output is at the same frequency as the AC line (50 Hz or 60 Hz). The Low Speed Starter is a separate sub-assembly within the Indico 100 Generator. The LSS part number corresponds to the value of phase-shift capacitor incorporated within this sub-assembly. The boost time is selectable to either 1.5 seconds or 2.5 seconds, and the run voltage is selectable to any of 52 VAC, 73 VAC or 94 VAC. CMP200 Generators Only The boost voltage may be set to either 240 VAC (factory default) or 120 VAC. This should be set to 240 VAC, except where specifically noted in Table 1 below. The Low Speed Starter output is at the same frequency as the AC line (50 Hz or 60 Hz). The Low Speed Starter is integrated into the HV Auxiliary Board within the CMP 200® and CMP 200® DR generators. The phase-shift capacitor is chassis-mounted and may be changed in the field. The LSS part number corresponds to the value of capacitor installed. The boost time is software-configurable from the console or GenWare®. Note that these generators do not use a separate run voltage, instead cycling the boost voltage on/off as required. The boost duty cycle is not hardware-configurable. Mobile DR Generators Only The Low Speed Starter is a separate sub-assembly within Mobile DR generator configurations. The boost voltage is 240 VAC at 60 Hz, boost time is 1.5 seconds, and provides a 30µF phase-shift capacitor. Use and disclosure is subject to the restrictions on the title page of this CPI document. Page 2 Rev. AD X-Ray Generator Service Manual Supplement 746026 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) TABLE 1: TUBE TYPES (LOW SPEED STARTER) INDICO IQ only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) CODE, INDICO 100 only OUTPUT RUN VOLTS Switches FREQ. (1........5) INDICO 100 / CMP200/DR only BOOST VOLTS INDICO IQ (See note 1) BOOST SHIFT TIME CAP. LSS PART NO. (See note 2) INDICO 100 SHIFT CAP. LSS PART NO. (See note 2) CMP200 / CMP200 DR SHIFT CAP. LSS PART NO. (See note 2) CGR (GE) MN640 Statorix 200A/240/260 M641 MN641 (50/110 stator) M643 CGR (GE) RN620 RN621 Statorix 550 (50/110 stator) Type 28 50 Hz (00111) 94 VAC 240 VAC 2.5 sec 12.5F 905135-41 12.5F 732752-01 N/A N/A Type 28 50 Hz (00111) 94 VAC 240 VAC 2.5 sec 12.5F 905135-41 12.5F 732752-01 N/A N/A Chirana Rotax KA 125 Type 21 60 Hz (10101) 73 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 30 F 903836-00 73 VAC 240 VAC 1.5 sec N/A N/A 100F, 732752-04 52 mH N/A N/A RIK-T 0.8/2.0 12/50 RIK-T 1.2/2.0 30/50 732752-00 (20/50 stator) Chirana Rotax KA 125 N/A N/A (20/20/20 stator) Comet DO7 / DX7 (25/50 stator) Comet DO9 / DX9 (20/50 stator) DX7 DX71HS (See note 3) Type 0 60 Hz (00000) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 DX9 DX91H / HS DX92H / HS DX93H / HS DX94HS DX96HS DX97HS Type 0 60 Hz (00000) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 (See note 3) Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 3 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only INDICO 100 only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Comet D010 / DX10 DX10H / HS DX101H / HS DX104HS DX105HS DX106HS (See note 3) DX700HS (See note 3) Type 0 60 Hz (00000) 52 VAC Type 1 60 Hz (10000) XSTAR8 (XST-8) XSTAR74 (XST-74) XSTAR-WHIS (20/50 stator) Comet DO700 / DX700 CODE, OUTPUT RUN VOLTS INDICO 100 / CMP200/DR only BOOST TIME INDICO 100 CMP200 / CMP200 DR SHIFT LSS PART NO. SHIFT CAP. (See note 2) CAP. LSS PART NO. SHIFT (See note 2) CAP. 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 N/A N/A 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A Type 0 60 Hz (00000) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 DA1002 (DU304-1.0/2.0) DA1029 (DU304-0.6/1.2) DA1036 (DU404-0.6/1.2) DA1083 (DU404-0.3/1.0) DA1092 (DU604-0.6/1.2) DA1094 (DU404-0.4/0.8) Type 4 60 Hz (00100) 52 VAC 240 VAC 2.5 sec (Indico) 33 F 30 F 40 F 905135-41 905135-43 905135-44 45 F (50 or 60 Hz) 732752-02 (prefer) 40 F (50 or 60 Hz) 903836-01 (prefer) 30 F (60 Hz only) 732752-00 30 F (60 Hz only) 903836-00 DU 1750 DU 3050 DU 2550 DU 33100 (See note 6) DU 1750 DU 3050 DU 2550 DU 33100 (See note 6) Type 9 60 Hz (10010) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 Type 9 60 Hz (10010) N/A N/A 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A Switches FREQ. (1........5) BOOST VOLTS INDICO IQ (See note 1) N/A LSS PART NO. (See note 2) (25/50 stator) Comet XSTAR (25/50 stator) Dunlee (Philips) DA10 series (20/50 stator) Dunlee (Philips) DA90, DA90HS (36/44 stator) (See note 4) Dunlee (Philips) DA90, DA90HS (9/11 stator) (See note 5) 2.0 sec (CMP200) N/A Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 4 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only INDICO 100 only INDICO 100 / CMP200/DR only INDICO IQ (See note 1) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Dunlee (Philips) DR1400 series DR1429 (DU304-0.6/1.2) DR1436 (DU404-0.6/1.2) DR1492 (DU604-0.6/1.2) DR1494 (DU404-0.4/0.8) Type 4 60 Hz (00100) DR1817 DR1833 Type 9 60 Hz (10010) 52 VAC 240 VAC 1.5 sec 33 F 30 F DR1817 DR1833 Type 9 60 Hz (10010) N/A N/A PX1302 (DU303-1.0/2.0) PX1312 (DU303-0.6/1.2) PX1351 (DU143-1.0/2.0) Type 7 60 Hz (11100) 52 VAC 240 VAC 2.5 sec (Indico) (20/50 stator) Dunlee (Philips) DR1800 series CODE, OUTPUT RUN VOLTS Switches FREQ. (1........5) 52 VAC BOOST VOLTS BOOST TIME 240 VAC 2.5 sec (Indico) 2.0 sec (CMP200) INDICO 100 CMP200 / CMP200 DR SHIFT LSS PART NO. SHIFT CAP. (See note 2) CAP. LSS PART NO. SHIFT (See note 2) CAP. 33 F 30 F 40 F 45 F (50 or 60 Hz) 732752-02 (prefer) 40 F (50 or 60 Hz) 903836-01 (prefer) 30 F (60 Hz only) 732752-00 30 F (60 Hz only) 903836-00 905135-41 905135-43 30 F 732752-00 30 F 903836-00 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 905135-41 905135-43 905135-44 LSS PART NO. (See note 2) (19/22 stator) (See note 4) Dunlee (Philips) DR1800 series N/A (9/11 stator) (See note 5) Dunlee (Picker / Philips) PX1300 series (3” anode) “S” stator (15/30 ) 2.0 sec (CMP200) Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 5 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Dunlee (Picker / Philips) PX1400 series CODE, INDICO 100 only OUTPUT RUN VOLTS Switches FREQ. (1........5) PX1402 (DU304-1.0/2.0) PX1412 (DU304-0.6/1.2) PX1415 (DU404-0.3/0.9) PX1425 (4” anode) PX1429 (DU304-0.6/1.2) “S” stator PX1431 (DU304-0.7/1.4) (15/30 ) PX1436 (DU404-0.6/1.2) PX1456 (DU404-0.3/1.0) PX1463 (DU604-0.6/1.2) PX1472 (DU604-0.3/1.0) PX1473 (DU404-0.6/1.2) PX1475 (DU754-0.6/1.2) PX1482 (DU404-0.6/1.0) PX1483 (DU404-0.3/1.0) PX1492 (DU604-0.6/1.2) PX1494 (DU404-0.4/0.8) Eureka (see Varian) Type 1 60 Hz (10000) GE Maxiray 75 (3” anode) (23/23 equal impedance “E” stator) Type 14 60 Hz (01110) 73 VAC Type 20 60 Hz (00101) 73 VAC * Dunlee tube GE Maxiray 100 (4” anode) (23/23 equal impedance “E” stator) MX-75 52 VAC INDICO 100 / CMP200/DR only BOOST VOLTS INDICO IQ (See note 1) BOOST SHIFT TIME CAP. INDICO 100 LSS PART NO. SHIFT (See note 2) CAP. CMP200 / CMP200 DR LSS PART NO. SHIFT (See note 2) CAP. LSS PART NO. (See note 2) 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 240 VAC 1.5 sec 45 F 40 F 905135-41 905135-44 45 F 732752-02 40 F 903836-01 240 VAC 1.5 sec 45 F 40 F 905135-41 905135-44 45 F 732752-02 40 F 903836-01 240 VAC 2.5 sec (Indico 2.0 sec (CMP200) DU303 (1.0/2.0) * DU303 (0.6/1.2) * MX-100 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 6 CPI Canada Inc. X-Ray Tube Stator Compatibility Tables INDICO IQ only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) CODE, INDICO 100 only OUTPUT RUN VOLTS Switches FREQ. (1........5) INDICO 100 / CMP200/DR only BOOST VOLTS INDICO IQ (See note 1) BOOST SHIFT TIME CAP. INDICO 100 LSS PART NO. SHIFT (See note 2) CAP. CMP200 / CMP200 DR LSS PART NO. SHIFT (See note 2) CAP. Gilardoni Rotagil S/AS AR11-30 AR20-50 AR30-00-1 AR30-60 AR30-100 AR40-100 AR9000-1 AR9000-2 Hangzhou Kailong (see Kailong RADII) Type 22 50 Hz (01101) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F Hangzhou Wandong WANRAY (Polygala / Yuan Zhi) XD51-20.40/125 (LQ16-XA2) XD51-10.40/125 (LQ16-XA4) XD52-30.50/125 (LQ17-XB1) XD57-20.50/150 (LQ16-XD57) IAE RTM 70H X20P C30, C31 X22 (28/57.5 stator) X40 (25/62 stator) X76 Type 0 60 Hz (00000) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 45 F 732752-02 (50 Hz) 40 F 903836-01 (50 Hz) Type 10 50 Hz (01010) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 30 F 732752-00 732752-00 30 F LSS PART NO. (See note 2) 903836-00 903836-00 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 7 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only INDICO 100 only INDICO 100 / CMP200/DR only INDICO IQ (See note 1) INDICO 100 CMP200 / CMP200 DR TUBE TYPE (HOUSING) TUBE TYPE (INSERT) IAE C40 (28/57.5 stator) (33/64 stator) X39 X40 X42 X76 Type 19 60 Hz (11001) 52 VAC 240 VAC 1.5 sec 25 F 20 F 905135-41 905135-42 30 F 732752-00 20 F 903836-02 IAE C52, C52 Super C100 C352 (20/40 stator) RTC 600HS RTC 700HS RTC 1000HS RTM 78H / HS RTM 90H / HS RTM 92H / HS RTM 101H / HS RTM 102H / HS RTM 780H / HS RTM 782H / HS X39 X40 X50H X50AH KL64 KL65 KL66 Type 27 50 Hz (11011) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 (prefer) 30 F 903836-00 (prefer) 45 F 732752-02 40 F 903836-01 Type 0 60 Hz (00000) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 KL74 KL80 KL80A KL86 Type 0 60 Hz (00000) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 732752-00 (prefer) Type 19 60 Hz (11001) 30 F (50 or 60 Hz) 40 F (50 Hz only) 20 F 903836-00 (prefer) KL76 30 F (50 or 60 Hz) 45 F (50 Hz only) 30 F Kailong RADII H1064 H1065 H1066 (25/62 stator) Kailong RADII H1074 H1080 H1086 CODE, OUTPUT RUN VOLTS Switches FREQ. (1........5) BOOST VOLTS BOOST SHIFT TIME CAP. LSS PART NO. SHIFT (See note 2) CAP. (20/50 stator) Kailong RADII H1076 52 VAC 240 VAC 1.5 sec 25 F 20 F 905135-41 905135-42 LSS PART NO. SHIFT (See note 2) CAP. 732752-02 732752-00 LSS PART NO. (See note 2) 903836-01 903836-02 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 8 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) CODE, INDICO 100 only OUTPUT RUN VOLTS Switches FREQ. (1........5) INDICO 100 / CMP200/DR only BOOST VOLTS INDICO IQ (See note 1) BOOST SHIFT TIME CAP. INDICO 100 LSS PART NO. SHIFT (See note 2) CAP. CMP200 / CMP200 DR LSS PART NO. SHIFT (See note 2) CAP. LSS PART NO. (See note 2) Machlett (see Varian) Philips ROT350 ROT351 (36/44 stator) (See note 4) * Dunlee tube (See note 6) ** NAGO tube *** Varian tube Philips ROT350 ROT351 (9/11 stator) (See note 5) * Dunlee tube (See note 6) ** NAGO tube *** Varian tube Philips ROT500 ROT501 RO 1230 RO 1750 / DU 1750* RO 2050 RO 3050 / DU 3050* SRO 2250 GD6 3050 ** PG-256 *** PG-292 *** RAD-34 *** RAD-50 *** Type 9 60 Hz (10010) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 RO 1230 RO 1750 / DU 1750* RO 2050 RO 3050 / DU 3050* SRO 2250 GD6 3050 ** PG-256 *** PG-292 *** RAD-34 *** RAD-50 *** Type 9 60 Hz (10010) N/A N/A N/A 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A SRM 0310 Type 30 60 Hz (01111) N/A N/A N/A 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A (9/11 stator) Picker (see Dunlee) Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 9 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only INDICO 100 only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Shimadzu CIRCLEX RX80 RX81 RX82 (7.5/35 stator) P18DE-85 Type 16 60 Hz (00001) 52 VAC Shimadzu CIRCLEX RX100 P38E Type 16 60 Hz (00001) Shimadzu CIRCLEX RX150 (8.4/24 stator) P18DK Type 16 60 Hz (00001) Siemens Opti-150 “S” stator (1-phase only) (14/18 ) * Varian tube Siemens SV 150 “S” stator (1-phase only) (14/18 ) * Varian tube 20/40 30/52R SG-796B * SV 150/40/80C-100L SG-256B * Siemens (SXVT) RAY-6_1 RAY-8(S)_1 RAY-12(S)_1 (1-phase only) (20/50 stator) Siemens (SXVT) RAY-13(S)_1 RAY-14(S)_1 (1-phase only) (20/50 stator) CODE, OUTPUT RUN VOLTS INDICO 100 / CMP200/DR only CMP200 / CMP200 DR LSS PART NO. SHIFT (See note 2) CAP. 120 VAC 1.5 sec (See note 10) 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 52 VAC 120 VAC 1.5 sec (See note 10) 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 52 VAC 120 VAC 1.5 sec (See note 10) 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 52 VAC 120 VAC 2.5 sec N/A (Indico) (See note 10) 2.0 sec (CMP200) N/A 45 F 732752-02 40 F 903836-01 Type 23 50 Hz (11101) N/A N/A 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A SV 150/12/40-S SV 150/25/48-S SV 150/22/54-S SV 150/33/78R-S Type 31 60 Hz (11111) 73 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 SV 150/33/78R-S Type 31 60 Hz (11111) 73 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 N/A N/A BOOST TIME INDICO 100 SHIFT LSS PART NO. SHIFT CAP. (See note 2) CAP. Switches FREQ. (1........5) BOOST VOLTS INDICO IQ (See note 1) N/A LSS PART NO. (See note 2) Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 10 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only INDICO 100 only INDICO 100 / CMP200/DR only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Siemens (SXVT) SDR (1-phase only) (20/50 stator) SDR 150/30/50-1 Type 31 60 Hz (11111) 73 VAC 240 VAC 1.5 sec Siemens (SXVT) SV 150 “S” stator (1-phase only) (14/18 ) Toshiba Rotanode SV 150/40/80C-100_1 Type 23 50 Hz (11101) 52 VAC Toshiba XH-112V-2 XH-112W XS-AA stator XS-AG stator (9.4/28.3 ) Toshiba XH-121 XH-126 XH-150 XS-AV stator XS-RA stator (27.5/58 ) Toshiba XH-112V-2 XS-AA stator XS-AG stator (9.4/28.3 ) (See note 7) CODE, OUTPUT RUN VOLTS Switches FREQ. (1........5) BOOST VOLTS BOOST TIME INDICO IQ (See note 1) INDICO 100 CMP200 / CMP200 DR SHIFT LSS PART NO. SHIFT CAP. (See note 2) CAP. LSS PART NO. SHIFT (See note 2) CAP. LSS PART NO. (See note 2) 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 120 VAC 2.5 sec 33 F (Indico) 30 F (See note 10) 2.0 sec (CMP200) 905135-41 905135-43 45 F 732752-02 40 F 903836-01 Most Toshiba x-ray tubes are identified by their “E” number, which is used to represent both the Tube Insert and the complete assembly. The housing number is usually not shown on the identification label. A specific “E” number may be available with several different stator types, each having different starter requirements. Furthermore, a specific stator type may require different starter requirements depending on the housing used. For ease of use, the Toshiba tubes are sorted by Tube Insert Type (“E” number) within this table. The installer must confirm the stator type for the planned tube(s). If the stator type is not identified within the Toshiba documentation, match the stator winding resistance to the appropriate table entry. Contact the factory if the desired Tube Type and stator type / winding resistance are not listed on the same row within this table. N/A N/A N/A 33 F 905135-41 DRX-3624H Type 17 60 Hz N/A N/A N/A N/A DRX-3724H 30 F 905135-43 (10001) DRX-4634H E7132 E7239 E7240 E7242 (See note 8) Type 19 60 Hz (11001) 52 VAC 240 VAC 1.5 sec E7250 (See note 8) Type 17 60 Hz (10001) N/A N/A N/A 25 F 20 F 905135-41 905135-42 30 F 732752-00 20 F 903836-02 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 11 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only INDICO 100 only INDICO 100 / CMP200/DR only INDICO IQ (See note 1) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Toshiba XH-106V XH-180 XH-181 XS-AL stator (9.4/28.3 ) E7252 (See note 8) Toshiba XH-106V XH-180 XH-181 XS-RA stator (27.5/58 ) E7252 (See note 8) Type 19 60 Hz (11001) 94 VAC 240 VAC 1.5 sec 25 F 20 F Toshiba XH-157 XS-RB stator (20.2/38 ) E7254 E7255 (See note 8) Type 21 60 Hz (10101) 52 VAC 240 VAC 1.5 sec Toshiba XH-121 XH-126 XS-AV stator XS-RA stator (27.5/58 ) Toshiba XH-106V XH-180 XS-AL stator (9.4/28.3 ) E7299 (See note 8) Type 19 60 Hz (11001) 52 VAC E7813 (See note 8) Type 29 60 Hz (10111) 52 VAC CODE, OUTPUT RUN VOLTS Switches FREQ. (1........5) Type 29 60 Hz (10111) 52 VAC BOOST VOLTS BOOST SHIFT TIME CAP. LSS PART NO. SHIFT (See note 2) CAP. CMP200 / CMP200 DR LSS PART NO. SHIFT (See note 2) CAP. LSS PART NO. (See note 2) 45 F (50 or 60 Hz) 732752-02 (prefer) 40 F (50 or 60 Hz) 903836-01 (prefer) 30 F (60 Hz only) 732752-00 30 F (60 Hz only) 903836-00 905135-41 905135-42 30 F 732752-00 20 F 903836-02 33 F 30 F 905135-41 905135-43 30 F (60 Hz only) 732752-00 30 F (60 Hz only) 903836-00 240 VAC 1.5 sec 25 F 20 F 905135-41 905135-42 30 F 732752-00 20 F 903836-02 120 VAC 1.5 sec (See note 10) 45 F 40 F 905135-41 905135-44 45 F (50 or 60 Hz) 30 F (60 Hz only) 732752-02 (prefer) 40 F (50 or 60 Hz) 30 F (60 Hz only) 903836-01 (prefer) 120 VAC 1.5 sec (See note 10) 45 F 40 F INDICO 100 905135-41 905135-44 732752-00 903836-00 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 12 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only INDICO 100 only INDICO 100 / CMP200/DR only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Toshiba XH-121 XS-BA stator (18/47.5 ) E7843 (See note 8) Toshiba XH-121 XH-126 XH-150 XS-RA stator (27.5/58 ) Toshiba XH-112V-2 XS-AG stator (9.4/28.3 ) Toshiba XH-121 XS-AV stator (27.5/58 ) Toshiba XH-112V-2 XS-AG stator (9.4/28.3 ) Toshiba XH-121 XS-AV-stator XS-RA stator (27.5/58 ) E7861 (See note 8) Type 19 60 Hz (11001) 94 VAC 240 VAC 1.5 sec E7864 (See note 8) Type 17 60 Hz (10001) N/A N/A E7865 (See note 8) Type 19 60 Hz (11001) 52 VAC 240 VAC 1.5 sec CODE, OUTPUT RUN VOLTS Switches FREQ. (1........5) Type 0 60 Hz (00000) 52 VAC BOOST VOLTS INDICO IQ (See note 1) BOOST SHIFT TIME CAP. 120 VAC 2.5 sec (See note 10) N/A N/A E7869 (See note 8) Type 17 60 Hz (10001) N/A N/A E7876 (See note 8) Type 19 60 Hz (11001) 94 VAC 240 VAC 1.5 sec 33 F 30 F INDICO 100 LSS PART NO. SHIFT (See note 2) CAP. 905135-41 905135-43 CMP200 / CMP200 DR LSS PART NO. SHIFT (See note 2) CAP. LSS PART NO. (See note 2) 45 F (50 or 60 Hz) 732752-02 (prefer) 40 F (50 or 60 Hz) 903836-01 (prefer) 30 F (60 Hz only) 732752-00 30 F (60 Hz only) 903836-00 25 F 20 F 905135-41 905135-42 30 F 732752-00 20 F 903836-02 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A 25 F 20 F 905135-41 905135-42 30 F 732752-00 20 F 903836-02 MOBILE DR GENERATOR 30 F 904832-00 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A 25 F 20 F 905135-41 905135-42 30 F 732752-00 20 F 903836-02 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 13 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only INDICO 100 only INDICO 100 / CMP200/DR only INDICO IQ (See note 1) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Toshiba XH-121 XH-126 XH-150 XS-AL stator (9.4/28.3 ) E7884 (See note 8) Toshiba XH-121 XH-126 XS-AV stator XS-RA stator (27.5/58 ) Varian (Machlett) Dynamax (DX) 52 “R” stator (16/50 ) Varian (Machlett) Dynamax (DX) 62 “R” stator (23/56 ) E7886 (See note 8) Type 19 60 Hz (11001) 94 VAC 240 VAC 1.5 sec 25 F 20 F A-102 A-132 A-142 Type 0 60 Hz (00000) 52 VAC 240 VAC 1.5 sec A-192B A-196 A-197 A-256 A-272 A-282 A-286 A-292 A-482 A-486 A-102 A-132 / A-134* A-142 / A-144* A-145 * (See note 9) Type 0 60 Hz (00000) Type 1 (10000) 52 VAC Type 2 60 Hz (01000) 52 VAC Dynamax (DX) 62U configured as “STD” or “R” stator (15/36 ) Varian B-100 “STD” stator (16/50 ) CODE, OUTPUT RUN VOLTS Switches FREQ. (1........5) Type 29 60 Hz (10111) 52 VAC BOOST VOLTS BOOST SHIFT TIME CAP. LSS PART NO. SHIFT (See note 2) CAP. CMP200 / CMP200 DR LSS PART NO. SHIFT (See note 2) CAP. 45 F (50 or 60 Hz) 30 F (60 Hz only) 732752-02 (prefer) 905135-41 905135-42 30 F 33 F 30 F 905135-41 905135-43 240 VAC 1.5 sec 33 F 30 F 240 VAC 1.5 sec 33 F 30 F 120 VAC 1.5 sec (See note 10) 45 F 40 F INDICO 100 LSS PART NO. (See note 2) 40 F (50 or 60 Hz) 30 F (60 Hz only) 903836-01 (prefer) 732752-00 20 F 903836-02 30 F 732752-00 30 F 903836-00 905135-41 905135-43 30 F 732752-00 30 F 903836-00 905135-41 905135-43 30 F 732752-00 30 F 903836-00 905135-41 905135-44 732752-00 903836-00 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 14 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Varian B-130 B-130H B-135H B-146 B-147 B-150 B-150H Std “R” stator (16/50 ) A-152 A-182 / A-184* A-192 / A-194* A-195 A-196 A-197 * (See note 9) A-272 / A-274* A-277 / A-278* A-282 / A-284* A-286 A-292 / A-294* A-482 G-242 G-256 G-292 / G-294* G-296 G-892 G-896 * (See note 9) G-1077 G-1078 G-1080 G-1082 / G-1084* G-1086 / G-1087* G-1092 / G-1094* * (See note 9) G-1582 G-1592 G-1593 Varian B-160 B-160H B-165H “R” Stator (16/50 ) Varian B-180 B-180H B-185 B-185H “R” Stator (16/50 ) CODE, INDICO 100 only OUTPUT RUN VOLTS Switches FREQ. (1........5) INDICO 100 / CMP200/DR only BOOST VOLTS INDICO IQ (See note 1) BOOST SHIFT TIME CAP. INDICO 100 LSS PART NO. SHIFT (See note 2) CAP. CMP200 / CMP200 DR LSS PART NO. SHIFT (See note 2) CAP. LSS PART NO. (See note 2) 52 VAC 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 Type 15 60 Hz (11110) N/A N/A N/A 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A Type 15 60 Hz (11110) N/A N/A N/A 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A Type 2 60 Hz (00000) Type 1 (10000) Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 15 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) INDICO IQ only TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Varian B-199 “S” Stator (15/18 ) Varian (Eureka) Diamond LEO Std “R” stator (20/50 ) Varian (Eureka) Diamond Std “R” stator (20/50 ) Varian (Eureka) Diamond Emerald Std “R” stator (20/50 ) Varian (Eureka) Sapphire Std “R” stator (20/50 ) SG-1096 Type 18 50 Hz (01001) RAD-12 RAD-13 RAD-14 RAD-68 CODE, INDICO 100 only OUTPUT RUN VOLTS INDICO 100 / CMP200/DR only INDICO IQ (See note 1) BOOST VOLTS BOOST SHIFT TIME CAP. N/A N/A N/A Type 0 60 Hz (00000) 52 VAC Type 0 60 Hz (00000) 52 VAC RAD-8 RAD-74 Type 0 60 Hz (00000) 52 VAC RAD-21 RAD-40 RAD-44 RAD-56 RAD-60 RAD-92 RAD-94 Type 5 60 Hz (10100) 52 VAC Switches FREQ. (1........5) INDICO 100 CMP200 / CMP200 DR LSS PART NO. SHIFT (See notes 2) CAP. LSS PART NO. SHIFT (See note 2) CAP. LSS PART NO. (See note 2) 33 F 30 F 905135-41 905135-43 N/A N/A N/A N/A 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 240 VAC 1.5 sec 33 F 30 F 905135-41 905135-43 30 F 732752-00 30 F 903836-00 MOBILE DR GENERATOR 30 F 904832-00 NOTE 1: For Indico IQ generators, the 905135-41 “universal” starter provides automatic selection of shift capacitance using relays located on the Low Speed Starter board. The dedicated 905135-42, 905135-43 and 905135-44 starters provide a fixed value using a single capacitor. NOTE 2: Where more than one Low Speed Starter part number is referenced for a particular tube type and generator combination, any of these is acceptable. In some cases, a preferred part number is identified. For 2-tube systems using different tube types, both tube types must be considered. Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 16 CPI Canada Inc. 2.0 X-Ray Tube Stator Compatibility Tables LOW SPEED STARTER TUBE SELECT TABLE (cont) NOTE 3: Comet tube inserts with the prefix “DI” and “DX” are interchangeable. NOTE 4: Philips / Dunlee housing with the windings connected in series (low-speed / high impedance configuration). NOTE 5: Philips / Dunlee housing with the windings connected in parallel (high-speed / low impedance configuration). NOTE 6: Dunlee tube inserts with the prefix “DU” and Philips tube inserts with the prefix “RO” are interchangeable. Select the corresponding Philips insert type within the Generator software if the Dunlee type is not available. NOTE 7: Siemens (SXVT) housing with the “phase-shifted” windings connected in parallel (low impedance, high speed configuration). NOTE 8: Complete Toshiba x-ray tube assemblies include the suffix “X, “FX”, “GX”, or “JX”, which are interchangeable with respect to rotor and anode characteristics. NOTE 9: These X-ray tubes incorporate a control grid. Grid control is currently not supported by CPI generators. Connect the grid connection to Ground when using these tubes, and select the insert type within the Generator software corresponding to the equivalent non-grid tube. NOTE 10: The starter boost voltage is 120 VAC. This is not available with two-tube Indico 100 generators. Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 17 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE The Dual Speed Starter (DSS) synthesizes its output frequencies independently of the line frequency and will operate all tubes at 60/180 Hz, unless a particular tube only has published ratings to operate at 150 Hz. In this case, the starter will output 50/150 Hz when set for these tubes. Unless indicated otherwise within Table 2, setting the switches to the code indicated for the applicable Tube Type selects all required operating parameters. The Dual Speed Starter part number corresponds to the AC line voltage (except Indico IQ) and the configuration of phase-shift capacitors installed. Reference notes are provided at the end of Table 2. Tube operating parameters for each switch code are contained in Table 3 for reference. TABLE 2: TUBE TYPES (HIGH SPEED STARTER) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) CGR (GE) Statorix 200A/240/260 (50/110 stator) CGR (GE) Statorix 550 (50/110 stator) CODE, OPERATING NOTES Switches (1........5) (SEE TABLE 3 FOR OPERATING PARAMETERS) MN640 M641 MN641 M643 Type 28 (00111) LOW SPEED OPERATION ONLY (See note 1) MS740 MSN740 MSN742 RSN742 Type 28 (00111) RN620 RN621 Type 28 (00111) RSN722 Type 28 (00111) Dual Speed Starters “-15” must be jumper-configured to provide the required 15.5 F low speed shift capacitance. Please see note 10 before attempting to use this Dual Speed Starter configuration. HIGH SPEED OPERATION ONLY (See note 1) For Dual Speed operation, contact factory. LOW SPEED OPERATION ONLY (See note 1) Dual Speed Starters “-15” must be jumper-configured to provide the required 15.5 F low speed shift capacitance. Please see note 10 before attempting to use this Dual Speed Starter configuration. HIGH SPEED OPERATION ONLY (See note 1) For Dual Speed operation, contact factory. OUTPUT FREQ. 50 Hz H.S. SHIFT CAP. N/A L.S. SHIFT CAP. 12.5F to 15.5F INDICO 100 DSS PART NO. (See note 2) 733317-15 735925-15 906894-15 (See note 10) INDICO IQ DSS PART NO. (See note 2) 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-15 901298-15 (See note 10) 906672-23 150 Hz 3 F 12.5F to 15.5F 733317-15 735925-15 906894-15 (See note 10) 904925-23 50 Hz N/A 12.5F to 15.5F 733317-15 735925-15 906894-15 (See note 10) 904925-23 901297-15 901298-15 (See note 10) 906672-23 901297-15 901298-15 (See note 10) 906672-23 150 Hz 3 F 12.5F to 15.5F Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 18 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Chirana Rotax KA 125 (20/50 stator, single phase) CODE, OPERATING NOTES 60 Hz H.S. SHIFT CAP. N/A L.S. SHIFT CAP. 30 F to 36 F INDICO 100 DSS PART NO. (See note 2) 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Type 0 (00000) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Type 0 (00000) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A Type 24 (00011) None 50/150 Hz 6 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Type 24 (10011) None 50/150 Hz 6 F 30 F to 36 F 30 F to 36 F 30 F to 36 F Switches (1........5) (SEE TABLE 3 FOR OPERATING PARAMETERS) RIK-T Type 21 (10101) LOW SPEED OPERATION ONLY (See note 1) Comet DO7 / DX7 (25/50 stator) DX7 DX71HS (See note 3) Type 0 (00000) Comet DO9 / DX9 (20/50 stator) DX9 DX91H / HS DX92H / HS DX93H / HS DX94HS DX96HS DX97HS (See note 3) DX10H (See note 3) DX10HS DX104HS (See note 3) DX105HS DX106HS (See note 3) Comet DO10 / DX10 (20/50 stator) OUTPUT FREQ. INDICO IQ DSS PART NO. (See note 2) 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 19 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Switches Comet DO700 / DX700 (25/50 stator) DX700HS (See note 3) (1........5) Type 24 (10011) Dunlee (Philips) DA10 series (20/50 stator) DA1002 (DU304-1.0/2.0) DA1029 (DU304-0.6/1.2) DA1036 (DU404-0.6/1.2) DA1083 (DU404-0.3/1.0) DA1092 (DU604-0.6/1.2) DA1094 (DU404-0.4/0.8) Dunlee (Philips) DA90 DA90HS (36/44 stator) (See note 4) DU 1750 DU 3050 DU 2550 DU 33100 (See note 6) DU 1750 DU 3050 (See note 6) DU 2550 (See note 6) DU 33100 (See note 6) DR1429 (DU304-0.6/1.2) DR1436 (DU404-0.6/1.2) DR1492 (DU604-0.6/1.2) DR1494 (DU404-0.4/0.8) Dunlee (Philips) DA90 DA90HS (9/11 stator) (See note 5) Dunlee (Philips) DR1400 (20/50 stator) CODE, OPERATING NOTES None 50/150 Hz H.S. SHIFT CAP. 6 F Type 4 (00100) None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Type 9 (10010) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30F 733317-13 735925-13 906894-13 Type 9 (10010) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 37.5F 904925-21 904925-23 Type 9 (10010) Type 9 (10010) Type 4 (00100) None 60/180 Hz 12.5F 37.5F 901297-16 901298-16 906672-21 906672-23 HIGH SPEED OPERATION ONLY (See note 1) None 180 Hz 12.5F 37.5F 733317-16 735925-16 906894-16 733317-17 735925-17 906894-17 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. L.S. SHIFT CAP. 30 F to 36 F INDICO 100 DSS PART NO. (See note 2) 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 INDICO IQ DSS PART NO. (See note 2) 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-13 903255-13 904925-21 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-13 901298-13 906672-21 906672-23 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 20 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Dunlee (Philips) DR 1800 (19/22 stator) (See note 4) DR1817 Dunlee (Philips) DR 1800 (9/11 stator) (See note 5) DR1817 DR1825 DR1833 Dunlee (Picker / Philips) PX1300 3” anode “S“ stator (15/30 ) PX1302 (DU303-1.0/2.0) PX1312 (DU303-0.6/1.2) PX1351 (DU143-1.0/2.0) Dunlee (Picker / Philips) PX1400 series 4” anode “S” stator (15/30 ) PX1402 (DU304-1.0/2.0) PX1412 (DU304-0.6/1.2) PX1415 (DU404-0.3/0.9) PX1425 PX1429 (DU304-0.6/1.2) PX1431 (DU304-0.7/1.4) PX1436 (DU404-0.6/1.2) PX1456 (DU404-0.3/1.0) PX1463 (DU604-0.6/1.2) PX1472 (DU604-0.3/1.0) PX1473 (DU404-0.6/1.2) PX1475 (DU754-0.6/1.2) PX1482 (DU404-0.6/1.0) PX1483 (DU404-0.3/1.0) PX1492 (DU604-0.6/1.2) PX1494 (DU404-0.4/0.8) Dunlee (Picker / Philips) PX1400 series 4” anode “Q” stator (6/12 ) CODE, LOW SPEED OPERATION ONLY (See note 1) 60 Hz H.S. SHIFT CAP. N/A Type 9 (10010) Type 9 (10010) Type 9 (10010) Type 7 (11100) LOW SPEED OPERATION ONLY (See note 1) HIGH SPEED OPERATION ONLY (See note 1) None 60 Hz N/A 37.5F 180 Hz 12.5F 37.5F 60/180 Hz 12.5F 37.5F None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Type 1 (10000) None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Type 13 (10110) None 60/180 Hz 20 F 60 F to 62 F 733317-02 735925-02 906894-02 Switches (1........5) Type 9 (10010) OPERATING NOTES (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. L.S. SHIFT CAP. 30F to 32F INDICO 100 DSS PART NO. (See note 2) 733317-13 735925-13 906894-13 733317-16 735925-16 906894-16 733317-17 735925-17 906894-17 INDICO IQ DSS PART NO. (See note 2) 904556-13 903255-13 904925-21 904925-22 904925-23 904925-21 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-13 901298-13 906672-21 906672-22 906672-23 901297-16 901298-16 906672-21 906672-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 904925-22 901297-02 901298-02 906672-22 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 21 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. H.S. SHIFT CAP. L.S. SHIFT CAP. INDICO 100 DSS PART NO. (See note 2) INDICO IQ DSS PART NO. (See note 2) CMP 200 DSS PART NO. (See note 2) Type 14 (01110) None 60/180 Hz 7.5 F 36 F to 37.5F 733317-12 735925-12 906894-12 904556-12 903255-12 904925-21 901297-12 901298-12 906672-21 MX-100 Type 20 (00101) None 60/180 Hz 7.5 F 36 F to 37.5F 733317-12 735925-12 906894-12 904556-12 903255-12 904925-21 901297-12 901298-12 906672-21 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 TUBE TYPE (INSERT) CODE, Switches (1........5) OPERATING NOTES Eureka (see Varian) GE Maxiray 75 (3” anode) 23/23 equal impedance “E” stator * Dunlee tube GE Maxiray 100 (4” anode) 23/23 equal impedance “E” stator Gilardoni Rotagil (33/36 stator) MX-75 AR11-30 AR30-60 Type 22 (01101) LOW SPEED OPERATION ONLY (See note 1) 50 Hz N/A 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Gilardoni Rotagil A/A5 (33/36 stator) AR20-50 AR30-100 AR40-100 Type 22 (01101) None 50/150 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 DU303 (1.0/2.0) * DU303 (0.6/1.2) * Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 22 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) IAE C30 C31 (25/62 stator) IAE C40 (28/57.5 stator) (33/64 stator) IAE C52 C52 Super C100 C352 (20/40 stator) CODE, OPERATING NOTES 50 Hz H.S. SHIFT CAP. N/A L.S. SHIFT CAP. 30 F to 36 F None 50/150 Hz 6 F Type 19 (11001) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F to 36 F 20 F to 30 F Type 27 (11011) LOW SPEED OPERATION ONLY (See note 1) 50 Hz N/A 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Type 27 (11011) None 50/150 Hz 5 F 30 F 733317-13 735925-13 906894-13 733317-17 735925-17 906894-17 Switches (1........5) (SEE TABLE 3 FOR OPERATING PARAMETERS) X20P X22 X40 RTM 70H RTM 70HS Type 10 (01010) LOW SPEED OPERATION ONLY (See note 1) Type 10 (01010) X39 X40 X42 X76 RTM 78H RTM 90H RTM 92H RTM 101H RTM 102H RTM 780H RTM 782H X39 X40 X42 X50H X50AH RTC 600HS RTC 700HS RTC 1000HS RTM 78HS RTM 90HS RTM 92HS RTM 101HS RTM 102HS RTM 780HS RTM 782HS OUTPUT FREQ. INDICO 100 DSS PART NO. (See note 2) 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 INDICO IQ DSS PART NO. (See note 2) 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 904925-23 * * Preferred 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 906672-23 * * Preferred 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 23 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) CODE, OPERATING NOTES OUTPUT FREQ. H.S. SHIFT CAP. L.S. SHIFT CAP. INDICO 100 DSS PART NO. (See note 2) INDICO IQ DSS PART NO. (See note 2) CMP 200 DSS PART NO. (See note 2) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30F to 32F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 904925-23 901297-13 901298-13 906672-21 906672-22 906672-23 Type 9 (10010) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 37.5F 904925-21 904925-23 901297-16 901298-16 906672-21 906672-23 Type 9 (10010) None 60/180 Hz 12.5F 37.5F 733317-16 735925-16 906894-16 733317-17 735925-17 906894-17 Type 9 (10010) HIGH SPEED OPERATION ONLY (See note 1) 180 Hz 12.5F 37.5F Switches (1........5) (SEE TABLE 3 FOR OPERATING PARAMETERS) Type 9 (10010) Machlett (see Varian) Philips ROT 350 ROT 351 (36/44 stator) (See note 4) * Dunlee tube (See note 6) ** NAGO tube *** Varian tube Philips ROT 350 ROT 351 (9/11 stator) (See note 5) * Dunlee tube (See note 6) *** Varian tube RO 1230 RO 1750 RO 2050 RO 3050 SRO 2250 DU 1750 * DU 3050 * GD6 3050 ** PG-256 *** PG-292 *** RAD-34 *** RAD-50 *** RO 1230 RO 1750 RO 3050 DU 1750 * DU 3050 * RO 2050 SRO 2250 PG-256 *** PG-292 *** RAD-34 *** RAD-50 *** RO 2550 RO 33100 SRO 1330 DU 2550 * DU 33100 * Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 24 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Philips ROT 500 ROT 501 (9/11 stator) SRM 0310 SRM 1080 SRM 35100 Switches (1........5) CODE, OPERATING NOTES (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. 60/180 Hz H.S. SHIFT CAP. 12.5F L.S. SHIFT CAP. 37.5F Type 30 (01111) Type 30 (01111) None HIGH SPEED OPERATION ONLY (See note 1) 180 Hz 12.5F 37.5F INDICO 100 DSS PART NO. (See note 2) 733317-16 735925-16 906894-16 733317-17 735925-17 906894-17 INDICO IQ DSS PART NO. (See note 2) 904925-21 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-16 901298-16 906672-21 906672-23 904556-13 903255-13 904925-21 904925-22 904556-13 903255-13 904925-21 904925-22 904556-13 903255-13 904925-21 904925-22 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 901297-13 901298-13 906672-21 906672-22 901297-13 901298-13 906672-21 906672-22 901297-13 901298-13 906672-21 906672-22 Picker (see Dunlee) Shimadzu (Circlex) RX80 RX81 RX82 (7.5/35 stator) P18DE-85 Type 16 (00001) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F 733317-13 735925-13 906894-13 P33D P38D P38DE-85 Type 16 (00001) HIGH SPEED OPERATION ONLY (See note 1) 180 Hz 5 F 30 F 733317-13 735925-13 906894-13 Shimadzu (Circlex) RX100 P38E Type 16 (00001) None 60/180 Hz 5 F 30 F 733317-13 735925-13 906894-13 Shimadzu (Circlex) P18DK Type 16 (00001) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F 733317-13 735925-13 906894-13 P38DK P324DK Type 16 (00001) HIGH SPEED OPERATION ONLY (See note 1) 180 Hz 5 F 30 F RX150 (8.4/24 stator) Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 25 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Siemens Biangulix “S” stator (1-phase only) (14/18 ) Siemens Opti-150 “S” stator (1-phase only) (14/18 ) BI 125/20/40 BI 125/30/50 BI 150/30/50 BI 150/30/52R * Varian tube Siemens OptiTop “S” stator (1-phase only) (14/18 ) 150/30/52R 150/40/72C 150/12/50 150/40/80 150/30/50 150/40/102C SG-796B * 150/40/80HC-100L 150/40/80HC-102L * Varian tube Siemens Optilix “S” stator (1-phase only) (14/18 ) SG-1096 * 150/30/50C-100L 150/40/80C-100L * Varian tube Siemens Megalix Siemens SV 125 “S” stator (1-phase only) (14/18 ) SG-256 * Siemens SV 150 “S” stator (1-phase only) (14/18 ) * Varian tube OUTPUT FREQ. H.S. SHIFT CAP. L.S. SHIFT CAP. INDICO 100 DSS PART NO. (See note 2) INDICO IQ DSS PART NO. (See note 2) CMP 200 DSS PART NO. (See note 2) HIGH SPEED OPERATION ONLY (See note 1) 150 Hz 5 F 30 F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 Type 23 (11101) HIGH SPEED OPERATION ONLY (See note 1) 150 Hz 5 F 30 F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 Type 23 (11101) None HIGH SPEED OPERATION ONLY (See note 1) 150 Hz 150 Hz 5 F 5 F 30 F 30 F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 Type 23 (11101) None HIGH SPEED OPERATION ONLY (See note 1) 150 Hz 150 Hz 5 F 5 F 30 F 30 F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 None 150 Hz 5 F 30 F 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-13 903255-13 904925-21 904925-22 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-13 901298-13 906672-21 906672-22 CODE, OPERATING NOTES Switches (SEE TABLE 3 FOR OPERATING PARAMETERS) (1........5) Type 23 (11101) 125/30/82CM-120LW 125/40/82CM-120LW Type 8 (00010) HIGH SPEED OPERATION ONLY (See note 1) 150 Hz 6 F 30 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 SV 150/30/50C-100L Type 23 (11101) HIGH SPEED OPERATION ONLY (See note 1) 150 Hz 5 F 30 F 733317-13 735925-13 906894-13 None 150 Hz 5 F 30 F SG-296B * Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 26 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Siemens SV 150 “S” stator (1-phase only) (14/18 ) SV 150/40/80C-100L SG-796B * Switches (1........5) (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. Type 23 (11101) None CODE, OPERATING NOTES 60/180 Hz H.S. SHIFT CAP. 5 F L.S. SHIFT CAP. 30 F INDICO 100 DSS PART NO. (See note 2) 733317-13 735925-13 906894-13 INDICO IQ DSS PART NO. (See note 2) 904556-13 903255-13 904925-21 904925-22 CMP 200 DSS PART NO. (See note 2) 901297-13 901298-13 906672-21 906672-22 * Varian tube Siemens (SXVT) RAY-6_1 RAY-8(S)_1 RAY-12(S)_1 (1-phase only) (20/50 stator) SV 150/12/40-S SV 150/25/48-S SV 150/22/54-S Type 31 (11111) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 904925-23 901297-13 901298-13 906672-21 906672-22 906672-23 Siemens (SXVT) RAY-13(S)_1 RAY-14(S)_1 (1-phase only) (20/50 stator) SV 150/33/78R-S Type 31 (11111) None 60/180 Hz 5 F 30 F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 Siemens (SXVT) SDR (1-phase only) (20/50 stator) SDR 150/30/50-1 Type 31 (11111) None 60/180 Hz 5 F 30 F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 Siemens (SXVT) SV 150 “S” stator (1-phase only) (14/18 ) SV 150/40/80C-100_1 Type 23 (11101) None 150 Hz 5 F 30 F 733317-13 735925-13 906894-13 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 (See note 7) Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 27 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Toshiba Rotanode Most Toshiba x-ray tubes are identified by their “E” number, which is used to represent both the Tube Insert and the complete assembly. The housing number is usually not shown on the identification label. A specific “E” number may be available with several different stator types, each having different starter requirements. Furthermore, a specific stator type may require different starter requirements depending on the housing used. For ease of use, the Toshiba tubes are sorted by Tube Type (“E” number) within this table. The installer must confirm the stator type for the planned tube(s). If the stator type is not identified within the Toshiba documentation, match the stator winding resistance to the appropriate table entry. Contact the factory if the desired Tube Type and stator type / winding resistance are not listed on the same line within this table. DRX-3624H 30 F Type 17 None 60/180 Hz 6 F 733317-12 904556-12 901297-12 DRX-3724H to 735925-12 903255-12 901298-12 (10001) DRX-4634H 906894-12 904556-13 901297-13 36 F 733317-13 903255-13 901298-13 735925-13 904925-21 906672-21 906894-13 904925-22 906672-22 904925-23 906672-23 20 F E7132 Type 19 60 Hz N/A 733317-13 904556-13 901297-13 LOW SPEED OPERATION ONLY to E7239 735925-13 903255-13 901298-13 (11001) (See note 1) E7240 906894-13 904925-21 906672-21 30 F E7242 904925-22 906672-22 904925-23 * 906672-23 * (See note 8) * Preferred * Preferred Toshiba XH-112V-2 XH-112W XS-AA stator XS-AG stator (9.4/28.3 ) Toshiba XH-121 XH-126 XH-150 XS-AV stator XS-RA stator (27.5/58 ) Toshiba XH-112V XS-AG stator (9.4/28.3 ) E7250 (See note 8) CODE, Switches (1........5) Type 17 (10001) OPERATING NOTES (SEE TABLE 3 FOR OPERATING PARAMETERS) None OUTPUT FREQ. 60/180 Hz H.S. SHIFT CAP. 6 F L.S. SHIFT CAP. 30 F to 36 F INDICO 100 DSS PART NO. (See note 2) 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 INDICO IQ DSS PART NO. (See note 2) 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 28 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Toshiba XH-106V XH-180 XH-181 XS-AL stator (9.4/28.3 ) Toshiba XH-106V XH-180 XH-181 XS-RA stator (27.5/58 ) Switches (1........5) (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. E7252 (See note 8) Type 29 (10111) None E7252 (See note 8) Type 19 (11001) CODE, OPERATING NOTES 60/180 Hz H.S. SHIFT CAP. 6 F L.S. SHIFT CAP. 30 F to 36 F INDICO 100 DSS PART NO. (See note 2) 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Dual Speed Starters “-15” must be jumper-configured to provide the required 28 F low speed shift capacitance. Please refer to note 10 before attempting to use this Dual Speed Starter configuration. LOW SPEED OPERATION ONLY (See note 1) 60/180 Hz 3 F 23 F to 28 F 733317-15 735925-15 906894-15 (See note 10) 60 Hz N/A 20 F to 30 F 733317-13 735925-13 906894-13 Toshiba XH-157 XS-RB stator (20.2/38 ) E7254 E7255 (See note 8) Type 21 (10101) None 60/180Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Toshiba E7299 (See note 8) Type 19 (11001) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 20 F to 30 F 733317-13 735925-13 906894-13 XH-121 XH-126 XS-AV stator XS-RA stator (27.5/58 ) INDICO IQ DSS PART NO. (See note 2) 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-15 901298-15 (See note 10) 906672-23 904556-13 903255-13 904925-21 904925-22 904925-23 * * Preferred 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-13 903255-13 904925-21 904925-22 904925-23 * * Preferred 901297-13 901298-13 906672-21 906672-22 906672-23 * * Preferred 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-13 901298-13 906672-21 906672-22 906672-23 * * Preferred Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 29 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Switches (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. L.S. SHIFT CAP. INDICO 100 DSS PART NO. (See note 2) INDICO IQ DSS PART NO. (See note 2) CMP 200 DSS PART NO. (See note 2) Toshiba E7813 (See note 8) (1........5) Type 29 (10111) H.S. SHIFT CAP. None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 E7843 (See note 8) Type 0 (00000) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 E7861 (See note 8) Type 19 (11001) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 20 F to 30 F 733317-13 735925-13 906894-13 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-13 903255-13 904925-21 904925-22 904925-23 * * Preferred 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-13 901298-13 906672-21 906672-22 906672-23 * * Preferred E7864 (See note 8) Type 17 (10001) None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 E7865 (See note 8) Type 19 (11001) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 20 F to 30 F 733317-13 735925-13 906894-13 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-13 903255-13 904925-21 904925-22 904925-23 * * Preferred 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-13 901298-13 906672-21 906672-22 906672-23 * * Preferred XH-106V XH-180 XS-AL stator (9.4/28.3 ) Toshiba XH-121 XS-BA stator (18/47.5 ) Toshiba XH-121 XH-126 XH-150 XS-RA stator (27.5/58 ) Toshiba XH-112V XS-AG stator (9.4/28.3 ) Toshiba XH-121 XH-126 XS-AV stator (27.5/58 ) CODE, OPERATING NOTES Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 30 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Switches (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. L.S. SHIFT CAP. INDICO 100 DSS PART NO. (See note 2) INDICO IQ DSS PART NO. (See note 2) CMP 200 DSS PART NO. (See note 2) Toshiba XH-112V XS-AG stator (9.4/28.3 ) E7869 (See note 8) (1........5) Type 17 (10001) H.S. SHIFT CAP. None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Toshiba E7876 (See note 8) Type 19 (11001) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 20 F to 30 F 733317-13 735925-13 906894-13 Toshiba XH-121 XH-126 XH-150 XS-AL stator (9.4/28.3 ) E7884 (See note 8) Type 29 (10111) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 Toshiba E7886 (See note 8) Type 19 (11001) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 20 F to 30 F 733317-13 735925-13 906894-13 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-13 903255-13 904925-21 904925-22 904925-23 * * Preferred 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-13 903255-13 904925-21 904925-22 904925-23 * * Preferred 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-13 901298-13 906672-21 906672-22 906672-23 * * Preferred 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-13 901298-13 906672-21 906672-22 906672-23 * * Preferred XH-121 XS-AV stator XS-RA stator (27.5/58 ) XH-121 XS-126 XS-AV stator XS-RA stator (27.5/58 ) CODE, OPERATING NOTES Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 31 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Varian/Machlett Dynamax 52 Std “R” stator (16/50 ) A-102 A-132 A-142 Varian/Machlett Dynamax 62 “STD” stator (23/56 ) Dynamax 62U configured as “STD” or “R” (15/36 ) Varian B-100 “R” stator (16/50 ) A-192B A-196 A-197 Type 0 (00000) A-256 A-272 A-282 A-292 A-482 Type 1 (10000) Varian B-100 “Q” stator (8/15 ) A-286 Switches (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. (1........5) Type 0 (00000) H.S. SHIFT CAP. L.S. SHIFT CAP. INDICO 100 DSS PART NO. (See note 2) INDICO IQ DSS PART NO. (See note 2) CMP 200 DSS PART NO. (See note 2) None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 733317-02 735925-02 906894-02 904925-22 901297-02 901298-02 906672-22 CODE, OPERATING NOTES A-486 A-102 A-132 / A-134* A-142 / A-144* * (See note 9) A-145 Type 0 (00000) None 60/180 Hz 6 F 30 F to 36 F Type 2 (01000) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A A-102 A-132 / A-134* A-142 / A-144* * (See note 9) Type 11 (11010) None 60/180 Hz 20 F 30 F to 36 F 60 F to 62 F Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 32 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Varian B-130 B-130H B-135H B-146 B-147 B-150 B-150H “R” stator (16/50 ) A-152 A-182 / A-184* A-192 / A-194* A-195 A-196 A-197 * (See note 9) A-272 / A-274* A-277 / A-278* A-282 / A-284 * A-286 A-292 / A-294* A-482 G-242 G-256 G-292 / G-294* G-296 G-892 G-896 * (See note 9) A-152 A-182 / A-184* A-192 / A-194* A-195 / A-196 A-197 / A-252 A-272 / A-274* A-277 / A-278* A-282 / A-284 * A-286 A-292 / A-294* A-482 G-242 G-256 G-292 / G-294* G-296 RAD-60 * (See note 9) Varian B-130 B-130H B-135H B-150 B-150H “Q” stator (6/11 ) Switches (1….....5) CODE, OPERATING NOTES (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. 60/180 Hz H.S. SHIFT CAP. 6 F L.S. SHIFT CAP. 30 F to 36 F INDICO 100 DSS PART NO. (See note 2) 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 INDICO IQ DSS PART NO. (See note 2) 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 Type 0 (00000) None None 60/180 Hz 20 F 60 F to 62 F 733317-02 735925-02 906894-02 904925-22 901297-02 901298-02 906672-22 Type 1 (10000) Type 12 (00110) Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 33 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Switches (1........5) Varian B-160 B-160H B-165H “R” Stator (16/50 ) (SEE TABLE 3 FOR OPERATING PARAMETERS) OUTPUT FREQ. G-1077 G-1078 G-1080 G-1082 / G-1084* G-1086 / G-1087* G-1092 / G-1094* * (See note 9) G-1582 G-1592 G-1593 Type 15 (11110) None Type 15 (11110) SG-1096 Varian B-240H “R” Stator (14/46 ) Varian (Eureka) Diamond LEO “R” stator (20/50 ) Varian B-180 B-180H B-185 B-185H “R” Stator (16/50 ) Varian B-199 “S” Stator (15/18 ) CODE, OPERATING NOTES 60/180 Hz H.S. SHIFT CAP. 6 F L.S. SHIFT CAP. 30 F to 36 F INDICO 100 DSS PART NO. (See note 2) 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 INDICO IQ DSS PART NO. (See note 2) 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 Type 18 (01001) None 50/150 Hz 5 F 30 F 904556-13 903255-13 904925-21 904925-22 901297-13 901298-13 906672-21 906672-22 G-2090 Type 6 (01100) None 100 / 180 Hz 6 F 12.5F to 20F 733317-13 735925-13 906894-13 733317-17 735925-17 906894-17 733317-16 735925-16 906894-16 904925-21 904925-22 904925-23 RAD-12 Type 0 (00000) LOW SPEED OPERATION ONLY (See note 1) 60 Hz N/A 30 F to 36 F RAD-13 RAD-14 RAD-68 Type 0 (00000) None 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 901297-16 901298-16 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 34 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) TUBE TYPE (HOUSING) TUBE TYPE (INSERT) Varian (Eureka) Diamond Emerald “R” stator (20/50 ) Varian (Eureka) Sapphire “R” stator (20/50 ) * For “Q” stator, refer to B-130 housing CODE, OPERATING NOTES Switches (1........5) (SEE TABLE 3 FOR OPERATING PARAMETERS) RAD-8 RAD-74 Type 0 (00000) LOW SPEED OPERATION ONLY (See note 1) RAD-21 RAD-40 RAD-44 RAD-56 RAD-60 * RAD-92 RAD-94 Type 5 (10100) None OUTPUT FREQ. 60 Hz H.S. SHIFT CAP. N/A L.S. SHIFT CAP. 30 F to 36 F INDICO 100 DSS PART NO. (See note 2) 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 60/180 Hz 6 F 30 F to 36 F 733317-12 735925-12 906894-12 733317-13 735925-13 906894-13 INDICO IQ DSS PART NO. (See note 2) 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 904556-12 903255-12 904556-13 903255-13 904925-21 904925-22 904925-23 CMP 200 DSS PART NO. (See note 2) 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 901297-12 901298-12 901297-13 901298-13 906672-21 906672-22 906672-23 NOTE 1: Tube types designated as low speed only or high speed only must be programmed for low speed only or high speed only operation. Refer to the section Tube Selection within Chapter 3 of the applicable generator service manual for details. For some tubes listed as high speed only, the starter may be capable of low speed operation but the Manufacturer’s data sheet for the Insert lists high speed only. In other cases, the limitation is due to operational limitations of the Dual Speed Starter itself. NOTE 2: Dual Speed Starter part numbers 733317-XX (Indico 100), 904556-XX (Indico IQ) and 901297-XX (CMP 200® DR) are used in 400 VAC 3 generators / power supplies and in 480 VAC 3 generators / power supplies with a line adjusting transformer. Dual Speed Starter part numbers 735925-XX (Indico 100), 903255-XX (Indico IQ) and 901298-XX (CMP 200® DR) are used in 230 VAC 1 generators / power supplies and in 480 VAC 3 direct input generators / power supplies (using no line adjusting transformer). Dual Speed Starter part numbers 906894-XX (Indico 100), 904925-XX (Indico IQ) and 906672-XX (CMP 200® DR) are used in both 400 VAC and 480 VAC 3 generators. These RoHS-compliant Starters replace the existing 73317-XX / 735925-XX series (Indico 100), 904556-XX / 903255-XX series (Indico IQ) and 901297-XX / 901298-XX series (CMP 200® DR), and may provide a greater selection of available shift capacitance. Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 35 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) Where more than one Dual Speed Starter part number is referenced for a particular tube type, any of these (applicable to the generator and input voltage) is acceptable. For 2-tube systems using different tube types, both tube types must be considered. Where available, the XXXXXX-21 starter is generally preferred, unless otherwise indicated in the tables. The Dual Speed Starters provide a selection of shift capacitance values for both high speed and low speed operation, as identified by the DSS part number suffix (“tab type”). Unless otherwise specified, capacitor selection is made automatically by relays located on the Dual Speed Starter board. The following table lists the capacitance values provided, along with applicable notes. DSS Part No. (applicability) XXXXXX-01 (Indico 100 only) XXXXXX-02 (All except Indico IQ) XXXXXX-12 (All except Indico IQ) XXXXXX-13 (All except Indico IQ) XXXXXX-15 (All except Indico IQ) HIGH-SPEED SHIFT CAPACITANCE LOW-SPEED SHIFT CAPACITANCE COMMENTS 6 F 31 F May be replaced by XXXXXX-21 in all configurations where available. 20 F 40 F 6 F, 7.5 F 36 F, 37.5 F Typically used to support “Q” stator tubes. May be replaced by XXXXXX-22 in all configurations, where available. May be replaced by XXXXXX-21 in all configurations, where available. 5 F, 6 F 30 F May be replaced by XXXXXX-21 in all configurations, where available. 3 F, 6 F Typically used to support CGR (GE) Statorix or Toshiba E7252 (XS-R/RA) tubes. May be replaced by XXXXXX-23 in all configurations, where available. Manual configuration required; see Note 10. XXXXXX-16 (All except Indico IQ) 6 F, 12.5 F 15.5 F, 18.5 F or 28 F, 31 F (manually selected) 12.5 F, 31.5 F, 37.5 F XXXXXX-17 (Indico 100 only) 5 F, 12.5 F 30 F, 37.5 F XXXXXX-21 (All except Indico 100) 5 F, 6 F, 7.5 F, 12.5 F 5 F, 6 F, 20 F 12.5 F, 30 F, 37.5 F 3 F, 6 F, 12.5 F 23 F, 32.5 F XXXXXX-22 (All except Indico 100) XXXXXX-23 (All except Indico 100) 20 F, 30 F, 62.5 F Used to support Philips ROT350/500 tubes. May be used in place of Dual Speed Starters “-12” or “-13” in two-tube systems that include both a standard “R” stator tube (6 F high speed shift capacitance) and a Philips ROT 350/500 tube. All such configurations may be replaced by XXXXXX-21, where available. Used in place of Dual Speed Starter “-13” in two-tube systems that include both a standard “R” stator tube (6 F of high speed shift capacitance) and an IAE tube (5 F of high speed shift capacitance). All such configurations may be replaced by XXXXXX-21, where available. Do not use these starters in place of XXXXXX-13 with Siemens tubes due to high-speed shift capacitor voltage limitations. Generally preferred where available, unless otherwise indicated within the tables. Typically used to support “Q” stator tubes. Preferred over XXXXXX-02, where available. Typically used to support CGR (GE) Statorix or Toshiba E7252 (XS-R/RA) tubes. Preferred over XXXXXX-15, where available. Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 36 CPI Canada Inc. 3.0 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER TUBE SELECT TABLE (cont) NOTE 3: Comet tube inserts with the prefix “DI” and “DX” are interchangeable. NOTE 4: Philips / Dunlee housing with the windings connected in series (low-speed / high impedance configuration). NOTE 5: Philips / Dunlee housing with the windings connected in parallel (high-speed / low impedance configuration). NOTE 6: Dunlee tube inserts with the prefix “DU” and Philips tube inserts with the prefix “RO” are interchangeable. Select the corresponding Philips insert type within the Generator software if the Dunlee type is not available. NOTE 7: Siemens (SXVT) housing with the “phase-shifted” windings connected in parallel (low impedance, high speed configuration). NOTE 8: Complete Toshiba x-ray tube assemblies include the suffix “X, “FX”, “GX”, or “JX”, which are interchangeable with respect to rotor and anode characteristics. NOTE 9: These X-ray tubes incorporate a control grid. Grid control is currently not supported by CPI generators. Connect the grid connection to Ground when using these tubes, and select the insert type within the Generator software corresponding to the equivalent non-grid tube. NOTE 10: Dual Speed Starters 733317-15 / 735925-15 / 906894-15 (Indico 100) and 901297-15 / 901298-15 (CMP 200® DR) have jumper selectable phase shift capacitance that allows selection of 15.5 F or 28 F low speed shift capacitors for operation with CGR (GE) Statorix or Toshiba E7252 (XS-R/RA stator) tubes, respectively, as per table 2. By default, this starter is factory set to the 28 F position. Confirm proper configuration per the section “Configuring Dual Speed Starter XXXXXX-15” in chapter 2 before proceeding. These starters also support standard “R” stators that require 6 F of high speed shift capacitance. (Indico 100 only): If configured for 28 F of low speed capacitance, these Dual Speed Starters also support tubes listed in Table 2 as requiring Dual Speed Starters 733317-13 / 735925-13 / 906894-15 and requiring 6 F of high speed capacitance. For two-tube operation, this configuration will support: a) These tubes and the Toshiba E7252/XS-RA (high and low speed) simultaneously, or; b) These tubes and a CGR Statorix tube (high-speed only) simultaneously. c) The Toshiba E7252/XS-RA and a CGR tube simultaneously if one or both of these tubes is operated in high-speed mode only. (CMP 200® DR only): If configured for 28 F of low speed capacitance, these Dual Speed Starters also support tubes listed in Table 2 as requiring Dual Speed Starters 901297-13 / 901298-13 and requiring 6 F of high speed capacitance. Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 37 CPI Canada Inc. 3.1 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER (and INDICO IQ LOW SPEED STARTER) TUBE CODES Tube operating parameters for each tube type are selected by setting switches to the applicable Code, as indicated in Table 1 (Indico IQ LSS) and Table 2 (DSS). For reference, operating parameters applicable to each Code are contained in Table 3 below. Reference notes are provided at the end of Table 3. TABLE 3: TUBE TYPE CODES (DUAL SPEED STARTER and INDICO IQ LOW SPEED STARTER) TUBE TYPE (CODE) Switches (1........5) H.S. START VOLTS H.S. RUN VOLTS H.S. BOOST TIME H.S. FREQ. H.S. BRAKE VOLTS H.S. BRAKE TIME L.S. START VOLTS L.S. RUN VOLTS L.S. BOOST TIME L.S. FREQ. Hz H.S. SHIFT CAP. APPLICABLE DSS TYPES (See note 1) 0 00000 400 V 100 V 1.4 sec 180 Hz 100 V 3.0 sec 240 V 60 V 1.4 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 1 10000 400 V 100 V 1.9 sec 180 Hz 100 V 3.0 sec 240 V 70 V 1.9 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 2 01000 400 V 100 V 1.0 sec 180 Hz 100 V 3.0 sec 240 V 60 V 1.0 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 3 11000 400 V 100 V 5.0 sec* 180 Hz 150 V 3.0 sec 240 V 70 V 5.0 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 * ( 2.5 sec Ready) 4 00100 420 V 70V 2.5 sec 180 Hz 170 V 3.0 sec* 240 V 50 V 1.6 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 * (LS braking 0.8 sec) 5 10100 400 V 100 V 2.3 sec 180 Hz 100 V 3.0 sec 240 V 50 V 2.3 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 -16, -21, * ( 5.0 sec Ready) -22, -23 ** (LS braking 2.0s) *** (12.5F-20F L.S. cap.) CODE 6 01100 440 V 140 V 6.0 sec* 180 Hz 250 V 4.0 sec** 400 V 110 V 5.0 sec 100 Hz 6 F *** 7 11100 240 V 120 V 2.3 sec 180 Hz 100 V 3.0 sec 240 V 50 V 2.3 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 8 00010 400 V 90 V 3.0 sec 150 Hz 100 V 3.0 sec 240 V 100 V 1.5 sec 50 Hz 6 F -12, -13, -15, -16, -21, -22, -23 9 10010 280 V 60 V 1.5 sec 180 Hz 80 V 3.0 sec 180 V 50 V 1.5 sec 60 Hz 12.5 F -12 (LS only), -16, -17, -21, -23, -22 (LS only) 10 01010 440 V 100 V 0.8 sec 150 Hz 120 V 1.8 sec 220 V 50 V 0.6 sec 50 Hz 6 F -12, -13, -15, -16, -21, -22, -23 11 11010 290 V 70 V 0.8 sec 180 Hz 60 V 3.0 sec 150 V 50 V 0.8 sec 60 Hz 20 F -02, -22 12 00110 290 V 60/80V 1.3 sec 180 Hz 60 V 3.0 sec 150 / 180 V 50 V 1.3 sec 60 Hz 20 F -02, -22 13 10110 340 V 60 V 1.0 sec 180 Hz 100 V 3.0 sec 240 V 70 V 1.0 sec 60 Hz 20 F -02, -22 14 01110 400 V 90 V 0.9 sec 180 Hz 80 V 2.0 sec 230 V 70 V 0.9 sec 60 Hz 7.5 F -12, -21 15 11110 400 V 100 V 5.0 sec 180 Hz 150 V 3.0 sec 240 V 70 V 5.0 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 38 CPI Canada Inc. 3.1 X-Ray Tube Stator Compatibility Tables DUAL SPEED STARTER (and INDICO IQ LOW SPEED STARTER) TUBE CODES (cont) TUBE TYPE (CODE) Switches (1........5) H.S. START VOLTS H.S. RUN VOLTS H.S. BOOST TIME H.S. FREQ. H.S. BRAKE VOLTS H.S. BRAKE TIME L.S. START VOLTS L.S. RUN VOLTS L.S. BOOST TIME L.S. FREQ. Hz H.S. SHIFT CAP. APPLICABLE DSS TYPES (See note 1) 16 00001 340 V 80 V 1.6 sec 180 Hz 80 V 3.0 sec 150 V 50 V 1.6 sec 60 Hz 5 F -13, -17, -21, -22, -23 (LS only) 17 10001 320 V 80 V 2.3 sec 180 Hz 100 V 3.0 sec 200 V 50 V 1.5 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 18 01001 400 V 100 V 2.8 sec 150 Hz 120 V 3.0 sec 180 V 60 V 1.5 sec 50 Hz 5 F -13, -17, -21, -22, -23 (LS only) 19 11001 320 V 130 V 2.0 sec 180 Hz 130 V 3.0 sec 240 V 60 V 1.4 sec 60 Hz 3 F -12, -13, -16, -21,-22 (all LS only), -15, -23 20 00101 400 V 90 V 1.0 sec 180 Hz 80 V 3.0 sec 230 V 70 V 1.0 sec 60 Hz 7.5 F -12, -21 21 10101 420 V 100 V 2.2 sec 180 Hz 150 V 3.0 sec 240 V 80 V 1.8 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 22 01101 340 V 60 V 1.4 sec 150 Hz 120 V 4.0 sec 220 V 60 V 1.5 sec 50 Hz 6 F -12, -13, -15, -16, -21, -22, -23 23 11101 360 V 90 V 1.6 sec 150 Hz 80 V 3.0 sec 150 V 50 V 1.6 sec 50 Hz 5 F -13, -21, -22, -23 (LS only) 24 00011 420 V 80 V 1.8 sec 150 Hz 150 V 3.0 sec 240 V 80 V 1.8 sec 50 Hz 6 F -12, -13, -15, -16, -21, -22, -23 25 10011 420 V 80 V 2.2 sec 150 Hz 150 V 3.0 sec 240 V 80 V 1.8 sec 50 Hz 6 F -12, -13, -15, -16, -21, -22, -23 26 01011 400 V 80 V 1.0 sec 150 Hz 120 V 3.0 sec 240 V 80 V 1.0 sec 50 Hz 5 F Reserved 27 11011 440 V 100 V 1.1 sec 150 Hz 120 V 1.8 sec 220 V 80 V 1.1 sec 50 Hz 5 F -13, -17, -21, -22, -23 (LS only) 28 00111 450 V 150 V 3.0 sec 150 Hz 120 V 3.0 sec 240 V 90 V 3.0 sec 50 Hz 3 F -15, -21 (LS only), -23 29 10111 240 V 60 V 2.2 sec 180 Hz 80 V 1.6 sec 130 V 50 V 1.3 sec 60 Hz 6 F -12, -13, -15, -16, -21, -22, -23 30 01111 420 V 50 V 1.8 sec 180 Hz 150 V 3.0 sec* 240 V 50 V 1.8 sec 60 Hz 12.5 F -16, -17, -21, -23 * (LS braking 1.2 sec) 31 11111 330V 80 V 1.4 sec 180 Hz 70V 3.0 sec 240 V 80 V 1.4 sec 60 Hz 5 F -13, -21, -22, -23 (LS only) CODE THE STARTER USES MODULATION STRATEGIES TO OBTAIN THE DESIRED OUTPUTS. MEASURED VOLTAGES MAY NOT AGREE WITH THOSE LISTED IN THE TABLE. HOWEVER, THE CURRENTS FLOWING IN THE STATOR WINDINGS ARE EQUIVALENT TO THOSE THAT WOULD EXIST IF THE STATOR WAS EXCITED WITH THESE VOLTAGES. NOTE 1: Tube Type codes should only be used with the applicable DSS types specified in this table (refer to Table 1 for applicable DSS Types). Refer to Table 1 for Indico IQ LSS Part Numbers applicable to each Tube Type (Housing and Insert). Refer to Table 2 for DSS Part Numbers applicable to each Tube Type (Housing and Insert). Use and disclosure is subject to the restrictions on the title page of this CPI document. X-Ray Generator Service Manual Supplement 746026 Rev. AD Page 39