LCP Series Datasheet

Pre-Engineered Solution Datasheet
LCP Fused Coordination Panel
Selective Coordination Panel
Features/Benefits
• Meets NEC® requirements
• Class CC and J fuse holders have built-in open-circuit indication
• Fast-acting UL Listed fuses protect against short circuits
• Feed through/sub feed lugs and 84-circuit configuration available
• Ground and neutral bars
• Copper bus standard
Advanced Design Options
Description
The Littelfuse® Coordination Panel provides a simple, time-saving solution for circuits that require selective
coordination. This UL Listed product saves time and money, and increases safety by minimizing system downtime.
Applications
•
•
•
•
MLO, Main Circuit Breaker, or Main Fused Pullout device
Fused Class T branch circuit pullout
Spare fuse cabinet accessory (holds six spare fuses)
TVSS overvoltage protection
Any NEMA enclosure required
High amperage sub-fed branch breakers (J60A)
Unique Specifier Tool (see pg. 146) to easily identify panel configurations from tens of thousands of options
Specifications
Voltage Ratings
Main Bus Rating
Conductor Terminals
UL Listed Elevators
Hospitals
Hotel and Entertainment Industry
Amusement Parks and Stadiums
120/208, 120/240, 277/480 VAC
100 A - 400 A Standard
6 AWG - 300 kcmil
UL 67 Panel boards and UL 50 Enclosures
Web Resources
Fuse Curves, sample requests, downloadable CAD
drawings and other technical information: Littelfuse.com/lcp
Code Requirements
Systems required by the NEC® to be selectively coordinated include:
•
•
•
•
•
•
•
•
•
•
•
•
Health Care Essential Electrical Systems (NEC 517.26)
Elevators (NEC 620.62)
Emergency Systems (NEC 700.27)
Legally Required Standby Systems (NEC 701.18)
Critical Operations Power Systems (NEC 708.54)
To quickly specify the LCP panel,
visit Littelfuse.com/lcp
and download the Specifier Tool.
Custom Options (select one from each column)
Number
of
Circuits
Voltage
Main Devices
120/208 V 3P, 4 W 125, 225, 400 or
600 A MLO
2 - 42
Neutral
Panel
Rating Mounting
Panel
Door
Fuse
Holders
100%
Surface
200%
Flush
Standard 30 A Class CC
Door-in-door 60 A Class J
†Fuses quoted separately to meet panel specifications. Coordination for breakers >60 A depends on upstream and
downstream devices. More specialized configurations are also available. Contact factory for more information.
Littelfuse.com
Panel
Feed
10 A- 60 A fused
circuit breaker
120/240 V 1P, 3 W
Up to 600 A MCB
or Main Fuse
Pullout
277/480 V 3P, 4 W
Branch circuit
protection devices
(1-3 pole) †
1 of 3
60 A-200 A
fused pullouts
Sub-fed circuit breakers
>60 A
(not fused)
Optional Lugs
Standard
Enclosure
Rating
None
NEMA 1
Sub-Fed (MLO panels)
NEMA 3R
Feed-Through
NEMA 4X
Top
Bottom
Note: The Littelfuse LPS, LPMP and LCP products are custom
designed products that fall outside standard specifications.
© 2013 Littelfuse POWR-GARD® Products
Rev: 011113
Pre-Engineered Solution Datasheet
LCP Fused Coordination Panel
Selective Coordination Panel
Dimensions mm (inches)
Dimensions in mm [inches]
Standard Coordination Panel Board (up toInner
30Linecircuits)
Dimensions in mm [inches]
GND Bus
GND Bus
152.4
[6.00]
152.4
[6.00]
711.2
[28.00]
711.2
246.06
[28.00]
[9.69]
246.06
[9.69]
Inner Line
711.2
[28.00]
711.2
419.1
[28.00]
[16.50]
227.01
[8.94]
227.01
[8.94]
Neutral Detail
419.1
[16.50]
Neutral Detail
(6 AWG - 300 kcmil) Cu/Al
Incoming Main Lugs
(6 AWG - 300 kcmil) Cu/Al
Incoming
Main Lugs
Cutler
Hammer
GHB (480 V) or BAB (208 V)
Cutler Breakers
Hammer
Circuit
GHB
(480 V) or BAB (208 V)
(or
Pullouts)
Circuit Breakers
(or Pullouts)
LPSC001ID POWR-Safe
Dead front Class CC 600 VAC
LPSC001IDfor
POWR-Safe
Fuseholder
use with Littelfuse
Dead front
CC 600
VAC
CCMR,
KLKRClass
or KLDR
Class
CC fuses
forLPSJ
use with
Littelfuse
orFuseholder
POWR-Safe
holders
for use
CCMR,
or KLDR
Class
fuses
the
ClassKLKR
J fuses.
(Fuses
not CC
included)
or POWR-Safe LPSJ holders for use
the Class J fuses. (Fuses not included)
Front View with Front Removed
Front View with Front Removed
609.6
[24.00]
609.6
[24.00]
Front Trim
Type 1 (NEMA) Enclosure
Front Trim
Type 1 (NEMA) Enclosure
914.4
[36.00]
914.4
[36.00]
Hinged Door with
Catch and Lock
Hinged Door with
Catch and Lock
Standard Coordination Panel Board (31-42 circuits)
Dimensions in mm [inches]
Dimensions in mm [inches]
GND Bus
152.4
[6.00]
152.4
[6.00]
GND Bus
711.2
[28.00]
711.2
246.06
[28.00]
[9.69]
246.06
[9.69]
Inner Line
Inner Line
227.01
[8.94]
227.01
[8.94]
Neutral Detail
711.2
[28.00]
711.2
419.1
[28.00]
[16.50]
419.1
[16.50]
Neutral Detail
(6 AWG - 300 kcmil) Cu/Al
Incoming Main Lugs
(6 AWG - 300 kcmil) Cu/Al
Incoming Main Lugs
Cutler Hammer
GHB (480 V) or BAB (208 V)
Cutler Breakers
Hammer
Circuit
GHB
(480 V) or BAB (208 V)
(or
Pullouts)
Circuit Breakers
(or Pullouts)
1066.8
[42.00]
1066.8
[42.00]
762
[30.00]
762
[30.00]
LPSC001ID POWR-Safe
Dead front Class CC 600 VAC
LPSC001IDfor
POWR-Safe
Fuseholder
use with Littelfuse
Dead front
CC 600
VAC
CCMR,
KLKRClass
or KLDR
Class
CC fuses
forLPSJ
use with
Littelfuse
orFuseholder
POWR-Safe
holders
for use
CCMR,
or KLDR
Class
fuses
the
ClassKLKR
J fuses.
(Fuses
not CC
included)
or POWR-Safe LPSJ holders for use
the Class J fuses. (Fuses not included)
Front Trim
Type 1 (NEMA) Enclosure
Front Trim
Type 1 (NEMA) Enclosure
Front View with Front Removed
Front View with Front Removed
Hinged Door with
Catch and Lock
Hinged Door with
Catch and Lock
Note: The Littelfuse LPS, LPMP and LCP products are custom
designed products that fall outside standard specifications.
Dimensions may change depending on panel components.
More specialized configurations are also available.
Contact factory for more information.
Littelfuse.com
2 of 3
© 2013 Littelfuse POWR-GARD® Products
Rev: 011113
Pre-Engineered Solution Datasheet
Excel® SPECIFIER tool for LCP COORDINATION PANEL
Simplify Communication
and Minimize Errors
Get Started Today!
A Microsoft Excel spreadsheet designed to help
engineers and contractors clearly convey which technical
components they would like incorporated into the
Littelfuse Coordination Panel.
1. Download The Specifier from Littelfuse.com/lcp or request it
from your Littelfuse sales representative
®
2.Fill it out to identify what you need (See sample below)
• Easily specify technical components of your panels /system
• Quickly and accurately captures desired electrical protection devices
3.Send it back to Littelfuse and get a quick quote
• Effectively manage each job with up-to-date
information
4.Automatically generate your custom Bill of
Material and base part number
• Ensures all pertinent information is captured to prevent unnecessary delays
LCP Fused Coordination Panel Specifier
Easy identification
for project
tracking
Fax to Your Local Littelfuse Rep Agency or Call 1-800-TEC-FUSE
Step 1
Job Name:
LCP42C-Sample
Panel ID:
Distributor:
Littelfuse Coordination Panel Circuit Schedule
Littelfuse Reps
Step 3
Input Values
42
Identify specific
panel options
Please configure individual feeder circuits by selecting fuse holder and breaker placement and size in
Drop down menus.
Littelfuse Distributor
LF Rep Agency:
Step 2
LF Quote #
H1EM1
277/480V 3 Phase, 4 Wire
Flush Mount
200A Main Breaker
200%
Bottom Feed
Feed-Through Lugs
Type 3R
Door-in-Door
# of Panel Circuits
Voltage, Phase, Wire
Mounting
Main Circuit Breaker
Neutral Rating
Panel Feed
Panel Options
Enclosure Rating
Panel Door
FUSE HOLDER
BKR
CKT#
PH.
CKT#
BKR
FUSE HOLDER
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
60A J Holder
60A J Holder
60A J Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
20/1
20/1
20/1
20/1
20/1
**60/3**
**//**
**///3**
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
A
B
C
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
**20/3**
**//**
**///3**
**20/3**
**//**
**///3**
**20/3**
**//**
**///3**
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
20/1
**60/2**
**//2**
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
30A CC Holder
60A J Holder
60A J Holder
Panel circuit
schedule identifies
specific branch
circuit protection
devices each
panel needs
***Consult Factory when specifying 2 Pole and 3 Pole Circuit Breakers ***
Bill of Materials
Automatically
generates base
part number
Part Numbers
Quantity
Base Part Number:
LCP 42 C
1
Options From above:
Mounting:
Main Circuit Breaker:
Neutral Rating:
Panel Feed:
Panel Options:
Enclosure Rating:
Panel Door:
Automatically
tabulates your
Bill of Material
to keep an
accurate count
Select Poles
1
3
2
Step 4
Flush Mount
1
200A Main Breaker
1
200%
1
Bottom Feed
1
Feed-Through Lugs
1
Type 3R
1
Door-in-Door
1
Enter Breaker Quantities From Above Panel Schedule
Breaker
Select Amperage
Breaker
20
31
Breaker
20
3
Breaker
60
1
Breaker
0
Breaker
0
Breaker
0
Breaker
0
Breaker
0
Fuseholder Quantities Calculate Automatically
30 Amp Class CC Holder
40
60 Amp Class J Holder
2
800-TEC FUSE
Littelfuse.com
www.littelfuse.com
3 of 3
© 2013 Littelfuse POWR-GARD® Products
Rev: 011113