Pre-Engineered Solution Datasheet LCP Fused Coordination Panel Selective Coordination Panel Features/Benefits • Meets NEC® requirements • Class CC and J fuse holders have built-in open-circuit indication • Fast-acting UL Listed fuses protect against short circuits • Feed through/sub feed lugs and 84-circuit configuration available • Ground and neutral bars • Copper bus standard Advanced Design Options Description The Littelfuse® Coordination Panel provides a simple, time-saving solution for circuits that require selective coordination. This UL Listed product saves time and money, and increases safety by minimizing system downtime. Applications • • • • MLO, Main Circuit Breaker, or Main Fused Pullout device Fused Class T branch circuit pullout Spare fuse cabinet accessory (holds six spare fuses) TVSS overvoltage protection Any NEMA enclosure required High amperage sub-fed branch breakers (J60A) Unique Specifier Tool (see pg. 146) to easily identify panel configurations from tens of thousands of options Specifications Voltage Ratings Main Bus Rating Conductor Terminals UL Listed Elevators Hospitals Hotel and Entertainment Industry Amusement Parks and Stadiums 120/208, 120/240, 277/480 VAC 100 A - 400 A Standard 6 AWG - 300 kcmil UL 67 Panel boards and UL 50 Enclosures Web Resources Fuse Curves, sample requests, downloadable CAD drawings and other technical information: Littelfuse.com/lcp Code Requirements Systems required by the NEC® to be selectively coordinated include: • • • • • • • • • • • • Health Care Essential Electrical Systems (NEC 517.26) Elevators (NEC 620.62) Emergency Systems (NEC 700.27) Legally Required Standby Systems (NEC 701.18) Critical Operations Power Systems (NEC 708.54) To quickly specify the LCP panel, visit Littelfuse.com/lcp and download the Specifier Tool. Custom Options (select one from each column) Number of Circuits Voltage Main Devices 120/208 V 3P, 4 W 125, 225, 400 or 600 A MLO 2 - 42 Neutral Panel Rating Mounting Panel Door Fuse Holders 100% Surface 200% Flush Standard 30 A Class CC Door-in-door 60 A Class J †Fuses quoted separately to meet panel specifications. Coordination for breakers >60 A depends on upstream and downstream devices. More specialized configurations are also available. Contact factory for more information. Littelfuse.com Panel Feed 10 A- 60 A fused circuit breaker 120/240 V 1P, 3 W Up to 600 A MCB or Main Fuse Pullout 277/480 V 3P, 4 W Branch circuit protection devices (1-3 pole) † 1 of 3 60 A-200 A fused pullouts Sub-fed circuit breakers >60 A (not fused) Optional Lugs Standard Enclosure Rating None NEMA 1 Sub-Fed (MLO panels) NEMA 3R Feed-Through NEMA 4X Top Bottom Note: The Littelfuse LPS, LPMP and LCP products are custom designed products that fall outside standard specifications. © 2013 Littelfuse POWR-GARD® Products Rev: 011113 Pre-Engineered Solution Datasheet LCP Fused Coordination Panel Selective Coordination Panel Dimensions mm (inches) Dimensions in mm [inches] Standard Coordination Panel Board (up toInner 30Linecircuits) Dimensions in mm [inches] GND Bus GND Bus 152.4 [6.00] 152.4 [6.00] 711.2 [28.00] 711.2 246.06 [28.00] [9.69] 246.06 [9.69] Inner Line 711.2 [28.00] 711.2 419.1 [28.00] [16.50] 227.01 [8.94] 227.01 [8.94] Neutral Detail 419.1 [16.50] Neutral Detail (6 AWG - 300 kcmil) Cu/Al Incoming Main Lugs (6 AWG - 300 kcmil) Cu/Al Incoming Main Lugs Cutler Hammer GHB (480 V) or BAB (208 V) Cutler Breakers Hammer Circuit GHB (480 V) or BAB (208 V) (or Pullouts) Circuit Breakers (or Pullouts) LPSC001ID POWR-Safe Dead front Class CC 600 VAC LPSC001IDfor POWR-Safe Fuseholder use with Littelfuse Dead front CC 600 VAC CCMR, KLKRClass or KLDR Class CC fuses forLPSJ use with Littelfuse orFuseholder POWR-Safe holders for use CCMR, or KLDR Class fuses the ClassKLKR J fuses. (Fuses not CC included) or POWR-Safe LPSJ holders for use the Class J fuses. (Fuses not included) Front View with Front Removed Front View with Front Removed 609.6 [24.00] 609.6 [24.00] Front Trim Type 1 (NEMA) Enclosure Front Trim Type 1 (NEMA) Enclosure 914.4 [36.00] 914.4 [36.00] Hinged Door with Catch and Lock Hinged Door with Catch and Lock Standard Coordination Panel Board (31-42 circuits) Dimensions in mm [inches] Dimensions in mm [inches] GND Bus 152.4 [6.00] 152.4 [6.00] GND Bus 711.2 [28.00] 711.2 246.06 [28.00] [9.69] 246.06 [9.69] Inner Line Inner Line 227.01 [8.94] 227.01 [8.94] Neutral Detail 711.2 [28.00] 711.2 419.1 [28.00] [16.50] 419.1 [16.50] Neutral Detail (6 AWG - 300 kcmil) Cu/Al Incoming Main Lugs (6 AWG - 300 kcmil) Cu/Al Incoming Main Lugs Cutler Hammer GHB (480 V) or BAB (208 V) Cutler Breakers Hammer Circuit GHB (480 V) or BAB (208 V) (or Pullouts) Circuit Breakers (or Pullouts) 1066.8 [42.00] 1066.8 [42.00] 762 [30.00] 762 [30.00] LPSC001ID POWR-Safe Dead front Class CC 600 VAC LPSC001IDfor POWR-Safe Fuseholder use with Littelfuse Dead front CC 600 VAC CCMR, KLKRClass or KLDR Class CC fuses forLPSJ use with Littelfuse orFuseholder POWR-Safe holders for use CCMR, or KLDR Class fuses the ClassKLKR J fuses. (Fuses not CC included) or POWR-Safe LPSJ holders for use the Class J fuses. (Fuses not included) Front Trim Type 1 (NEMA) Enclosure Front Trim Type 1 (NEMA) Enclosure Front View with Front Removed Front View with Front Removed Hinged Door with Catch and Lock Hinged Door with Catch and Lock Note: The Littelfuse LPS, LPMP and LCP products are custom designed products that fall outside standard specifications. Dimensions may change depending on panel components. More specialized configurations are also available. Contact factory for more information. Littelfuse.com 2 of 3 © 2013 Littelfuse POWR-GARD® Products Rev: 011113 Pre-Engineered Solution Datasheet Excel® SPECIFIER tool for LCP COORDINATION PANEL Simplify Communication and Minimize Errors Get Started Today! A Microsoft Excel spreadsheet designed to help engineers and contractors clearly convey which technical components they would like incorporated into the Littelfuse Coordination Panel. 1. Download The Specifier from Littelfuse.com/lcp or request it from your Littelfuse sales representative ® 2.Fill it out to identify what you need (See sample below) • Easily specify technical components of your panels /system • Quickly and accurately captures desired electrical protection devices 3.Send it back to Littelfuse and get a quick quote • Effectively manage each job with up-to-date information 4.Automatically generate your custom Bill of Material and base part number • Ensures all pertinent information is captured to prevent unnecessary delays LCP Fused Coordination Panel Specifier Easy identification for project tracking Fax to Your Local Littelfuse Rep Agency or Call 1-800-TEC-FUSE Step 1 Job Name: LCP42C-Sample Panel ID: Distributor: Littelfuse Coordination Panel Circuit Schedule Littelfuse Reps Step 3 Input Values 42 Identify specific panel options Please configure individual feeder circuits by selecting fuse holder and breaker placement and size in Drop down menus. Littelfuse Distributor LF Rep Agency: Step 2 LF Quote # H1EM1 277/480V 3 Phase, 4 Wire Flush Mount 200A Main Breaker 200% Bottom Feed Feed-Through Lugs Type 3R Door-in-Door # of Panel Circuits Voltage, Phase, Wire Mounting Main Circuit Breaker Neutral Rating Panel Feed Panel Options Enclosure Rating Panel Door FUSE HOLDER BKR CKT# PH. CKT# BKR FUSE HOLDER 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 60A J Holder 60A J Holder 60A J Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 20/1 20/1 20/1 20/1 20/1 **60/3** **//** **///3** 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 A B C A B C A B C A B C A B C A B C A B C 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 **20/3** **//** **///3** **20/3** **//** **///3** **20/3** **//** **///3** 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 **60/2** **//2** 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 30A CC Holder 60A J Holder 60A J Holder Panel circuit schedule identifies specific branch circuit protection devices each panel needs ***Consult Factory when specifying 2 Pole and 3 Pole Circuit Breakers *** Bill of Materials Automatically generates base part number Part Numbers Quantity Base Part Number: LCP 42 C 1 Options From above: Mounting: Main Circuit Breaker: Neutral Rating: Panel Feed: Panel Options: Enclosure Rating: Panel Door: Automatically tabulates your Bill of Material to keep an accurate count Select Poles 1 3 2 Step 4 Flush Mount 1 200A Main Breaker 1 200% 1 Bottom Feed 1 Feed-Through Lugs 1 Type 3R 1 Door-in-Door 1 Enter Breaker Quantities From Above Panel Schedule Breaker Select Amperage Breaker 20 31 Breaker 20 3 Breaker 60 1 Breaker 0 Breaker 0 Breaker 0 Breaker 0 Breaker 0 Fuseholder Quantities Calculate Automatically 30 Amp Class CC Holder 40 60 Amp Class J Holder 2 800-TEC FUSE Littelfuse.com www.littelfuse.com 3 of 3 © 2013 Littelfuse POWR-GARD® Products Rev: 011113