Power Distribution - Carling Technologies

Power Distribution
AC & DC Power
Distribution
and Battery
Disconnects
Carling
Technologies
Introduction to Power Distribution
™
With over 80 years of experience in the development of power switching and protection components, Carling Technologies offers
standard and custom designed AC and DC power distribution centers that provide the utmost in safety, reliability and performance.
Power Distribution Center, or PDC, is Carling's term for a standard or custom power distribution panel or unit that's factory wired and
contains overcurrent and short circuit protection devices. It may also contain auxiliary devices such as surge suppressors, ground
fault circuit interrupters, power receptacles, etc. A PDC is usually supplied by the main feeder and then divides the power into smaller branch circuits. A PDC provides the required circuit control and overcurrent protection needed to all the circuits and the loads connected to it. Power Distribution Unit, or PDU, is an industry term for horizontally mounted panels used in 19” or 23” racks.
Carling Technologies’ expertise in custom design solutions, tooling, manufacturing, and our broad customer base has allowed us to
develop a high quality standard product line of power distribution centers. Our standard PDU and PDC products have been designed
to meet today's demanding global industry standards, taking into account the growing need to reduce the amount of real estate that
panels require, without sacrificing power.
In addition, our dedicated engineering team designs and develops custom Power Distribution Centers or Battery Disconnect Panels
that will meet your special requirements. Utilizing a comprehensive range of quality circuit protection and control products, you can
specify the physical size of the enclosure and add your component requirements including temperature stable Carling Technologies'
hydraulic-magnetic circuit breakers, ground fault circuit protectors, transient voltage surge suppressors, meters, power receptacles,
relays, bus bars, hole plugs and LED's.
For the Telecommunication, Server, Marine, Generator, Alternative Power, and Medical industries, Carling Technologies' expertise in
power distribution and electrical design can help you meet your power needs. Contact us with your requirements today.
CHARGER/
RECTIFIER
DC DISTRIBUTION
DC
LOAD
LDC1, LDC2 &
LDM1-Series
DC
LOAD
CHARGER/
RECTIFIER
DC DISTRIBUTION
AC DISTRIBUTION
BATTERY DISCONNECT
BATTERY DISCONNECT
DC
LOAD
DC
LOAD
LDC1, LDC2 &
LDM1-Series
LBD-Series
˜
UTILITY POWER
˜
LAC1-Series
LBD-Series
ALARM/MONITOR
BATTERY
BANK A
BATTERY
BANK B
L0039
GENERATOR
(BACK-UP)
Block Diagram illustrating a typical telecommunications power distribution circuit featuring Carling Technologies PDU and PDC
products. The Power Distribution circuit can be fed by utility power on a back-up generator. In addition, battery power can be
supplied and controlled with Carling Technologies Battery Disconnect PDU’s. The DC Power Distribution can be monitored by
Carling Technologies Alarm/Monitor PDU.
www.carlingtech.com
Carling
Technologies
Contents
™
Carling Technologies’ Products
Within this catalog, you’ll find a comprehensive line of AC & DC Power Distribution Units (PDU’s), AC Power Distribution Centers
(PDC’s), and Battery Disconnect Panels for the Telecom market. All DC products are designed to fit into industry standard 19”
and 23” racks, from 1RU to 3RU, and utilize Carling hydraulic/magnetic breakers. We also offer custom power distribution products, hydraulic/ magnetic circuit breakers, thermal circuit protectors, switches, electronic controls and digital switching systems.
For more information on these products, please request one of the catalogs listed on the inside back cover of this catalog, or go
to www.carlingtech.com.
How To Use This Catalog
Please refer to the Product Selector Guide, located on this page, for the type of PDC required. Product features/specifications and
dimensional drawings are provided to assist you with product selection. Follow our easy, step-by-step, catalog number sequence
to construct the PDC which meets your needs. An example for constructing a catalog number is provided for each Series.
Customer Care Center
For additional application assistance, we urge you to consult with our experienced staff in our Customer Care Center. Our
Technical and Engineering staff has extensive test, research and development capabilities, and have assisted many customers in
solving unique design and application problems with standard or customized products. Please refer to our location listing on the
back of this catalog for contact information for your area.
We look forward to working with you.
Power Distribution Product Selector Guide
Type
# Circuits
# Circuits
protected by protected by Circuit
Bus
Circuit breaker GMT fuse
Current Current Voltage Alarm Mounting Size Page
Series
LDM1-Series
DC
Dual
Feed
PDU
18 total
(9 per feed)
_
25A
max
150A 36 to 60
per feed (- DC)
Yes
19" or 23" 1RU
rack
2
12 total
(6 per feed)
_
50A
max
150A 36 to 60
per feed (- DC)
Yes
19" or 23" 1RU
rack
5
12 total
(6 per feed)
8 total
(4 per feed)
50A
max
150A 36 to 60
per feed (- DC)
Yes
23" rack
1RU
8
13 poles
_
50A
max
No
Vertical
_
10
LDC1-Series
LDC2-Series
LAC1-Series
AC PDC
LBDP-Series
Battery
Disconnect
LBDP1
1 up to 250A
250A
LBDP1
1 up to 400A
400A
LBDP3
1 up to 700A
100A
1RU
19" rack
700A
_
_
LBDP1
1 up to 250A
250A
LBDP1
1 up to 400A
400A
LBDP3
1 up to 700A
700A
120/240
AC
125 VDC
max
2RU
3RU
No
13
Vertical
_
Accessories
16
Custom Power Distribution Solutions
17
Power Distribution Project Design Form
19
www.carlingtech.com
1
Carling
Technologies
LDM1-Series DC Secondary Power Distribution
™
To help conserve valuable cabinet space, Carling Technologies
introduces a new, advanced 1RU DC Power Distribution Unit
(PDU) for the telecom industry. This new PDU is designed to
fit industry standard 19” rack systems. This 1RU is listed to
UL/CUL 1801 and designed to EN60950.
LDM1-Series:
19” or 23” One Rack Unit
The LDM1-Series One Rack Unit (1RU) saves valuable
real estate on a rack, while offering ease
of installation and service.
General Specifications
Standards:
Dimensions:
Enclosure:
Feeds:
Load Connections:
Operating Voltage:
Alarm Feature:
LED indicators:
Chassis Ground:
2
The Carling circuit breakers installed in the 1RU are the miniature M-Series hydraulic-magnetic breakers — the smallest
breaker on the market that is UL489A listed up to 80 VDC. In
addition, these breakers are plug in style to allow for hot
“swappable” and front access, and are rated to 25 amps per
pole.
Even as a “condensed” panel, this new 1RU exceeds the
tough demands of today's applications while still offering safety, reliability and performance.
Features & Benefits
UL 1801, CUL Approved
Rack mounts to EIA standard
EIA-310-D 19" rack for a 1RU
panel, 1.75"H.
16 gauge yellow zinc chromate
cold rolled steel.
Dual, rated up to 150 amps per
feed.
Max. circuit breakers per feed: 9
Max. breaker rating: 25 amps.
Connections: two hole
compression lugs for 1/4 - 20
stud terminals x 5/8 centers.
Requires 10 awg wire/ring or fork
terminal for 25 A/75 C Rating,
Top or bottom wire entry.
-36V to –60V DC
(-48VDC nominal)
Power alarm: If either A or B
FEED or both fail.
Breaker alarm: If any populated
breaker is OFF or "tripped."
Alarm is not affected by unused
breaker positions. LED indicators
on the front panel. Breaker slots
can be set or deactivated on the
removable Alarm Card.
Green lamps on A and B feeds.
Red lamp for tripped breaker
alarm indication.
Via studs on the back panel. Use
two hole X 5/8" center lugs.
Grounding is also achieved
through the rack mounting
brackets to the yellow zinc
chromate steel panel enclosure.
•
•
•
•
•
•
•
•
•
•
•
•
Panel incorporates Carling M-Series style
hydraulic/magnetic breakers: The smallest UL489A
listed hydraulic-magnetic circuit breaker on the market
today!
Keyed terminal to prevent breaker from being
mounted incorrectly.
Hot “swappable” circuit breakers that can be
installed, changed, or replaced in the field or factory.
Circuit breakers are front panel accessible.
Maximum of 9 circuit breakers per feed; 18 per panel.
One Rack Unit (1RU) size.
Panel plugs provided for non populated circuit breaker
slots.
Rockerguard circuit breakers to prevent accidental
operation.
Panel is easily configurable and upgradeable in the
field. Provides flexibility when designing added
features or options.
Conserves valuable cabinet space to meet the tough
demands of today’s applications.
Front accessible removable alarm card.
Optional Rack Extenders to expand the panel
mounting from a 19" rack to a 23" rack.
Part Numbers:
8L1-A-DC1A (offset mounting)
8L1-A-DC1B (center mounting)
www.carlingtech.com
Carling
Technologies
LDM1-Series DC Secondary Power Distribution
™
LDM1-Series Ordering Scheme
LDM1 - B M - 05 20 10 01 03 25 15 H7 20
1
Series
2
Rocker
Style
4
Breaker in
Position 1
3
Delay
5
Breaker in
Position 2
6
Breaker in
Position 3
7
Breaker in
Position 4
1 SERIES
LDM1
2 ROCKER STYLE
N
No breaker
B
Black with white legend
3 DELAY
N
No breaker
8
Breaker in
Position 5
9
Breaker in
Position 6
10
Breaker in
Position 7
11
Breaker in
Position 8
4 through 12 BREAKER RATING
00
No breaker
01
1 amp
03
3 amps
05
5 amps
H7 7.5 amps
W
White Visi-Rocker
indicate OFF
M
Medium Delay, Curve 14
13 APPROVALS
A No approvals
G
UL/CUL
10
12
15
20
25
-A
12
Breaker in
Position 9
13
Approvals
10 amps
12 amps
15 amps
20 amps
25 amps
J UL/CUL, CE, TUV
NOTES:
Redundant feed. Breaker layout will be duplicated on the second feed.
Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed.
A panel plug will be supplied in the breaker positions that do not have a circuit breaker selected.
LDM1-Series Dimensional Specifications
1.750 {44.45}
17.74[450.6]
A
8.56[217.4]
A
19.000 {482.6}
23.000 {584.2} with Optional Rack Extenders
www.carlingtech.com
3
Carling
Technologies
LDM1-Series DC Secondary Power Distribution
™
Circuit Breakers
Circuit breakers can be ordered separately to upgrade or reconfigure panel at a later date.
Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory.
General Specifications:
UL/CUL and TUV approved
10000
STANDARD TRIP, MEDIUM DELAY, CURVE #14
MEDIUM DELAY CURVE
NOS. 14, 24, 34, 64, 74 & 94
RATING (amps)
BLACK ROCKER
WHITE VISI-ROCKER
1
MA1-X-00-927-2-A26-2-J
ME1-X-00-927-5-A16-2-J
3
MA1-X-00-902-7-A26-2-J
ME1-X-00-927-6-A16-2-J
5
MA1-X-00-902-6-A26-2-J
ME1-X-00-927-7-A16-2-J
7.5
MA1-X-00-927-3-A26-2-J
ME1-X-00-927-8-A16-2-J
10
MA1-X-00-902-5-A26-2-J
ME1-X-00-927-9-A16-2-J
12
MA1-X-00-927-47-A26-2-J
ME1-X-00-928-0-A16-2-J
15
MA1-X-00-902-4-A26-2-J
ME1-X-00-928-1-A16-2-J
20
MA1-X-00-902-3-A26-2-J
ME1-X-00-928-2-A16-2-J
25
MA1-X-00-897-5-A26-2-J
ME1-X-00-928-3-A16-2-J
TRIP TIME IN SECONDS
1000
100
10
1
.1
.01
.001
100
300
200
400
500
600
700
800
900
1000
1100
1200
135
150
PERCENT OF RATED CURRENT
M-SERIES TIME DELAY VALUES
TRIP
PERCENT OF RATED CURRENT
TIME
Delay
100%
135%
150%
200%
400%
600%
800%
1000%
1200%
(SECONDS)
14,24,34,64,74,94
No Trip
3.00-70.0
2.00-40.0
1.00-15.0
.100-4.00
.008-2.00
.006-.800
.005-.350
.005-.160
Circuit Breakers Dimensional Specifications
SINGLE POLE
±.030
±.76
.360 [9.14]
.305 [7.75]
.770 [19.56]
.680 [17.27]
1.530 [38.86]
.675 [17.14]
LOAD
ON
1.560 [39.62]
.970 [24.64]
.915 [23.22]
1.375 [34.93]
1.050 [26.67]
OFF
LINE
20A
.100 [2.54]
.400 [10.16]
±.030
[±.76]
1.870 [47.46]
TERMINAL DIMENSIONAL DETAIL
PANEL CUT - OUT DETAILS:
FRONT PANEL SNAP-IN MOUNTING
1.000 [25.4]
PANEL
THICKNESS
.392 [9.97]
CENTERLINE OF PUSH-IN STUD
CONTACT AREA
DIM. A
.100 [2.54]
.154 [3.91] DIA
±.005
±.13
.062 [1.57]
1.385 [35.18]
.093 [2.36]
1.420 [36.07]
.125 [3.18]
1.460 [37.08]
.71 [33.76]
.750 [19.05]
SOCKET MOUNT WITH FRONT
PANEL ACCESS FOR ROCKER
+.002
-.000
[+.050]
[-.000]
.700 [17.78]
.161 DIA [Ø 4.10]
PUSH-IN STUD
MATING HOLE
4
1.070 [27.18]
www.carlingtech.com
DIM. A
+.005 +.13
-.000 -.00
Carling
Technologies
LDC1-Series DC Secondary Power Distribution
™
To help conserve valuable panel space, Carling Technologies
introduces a new 1RU DC Power Distribution Unit (PDU) for
the telecom industry. This new PDU is designed to fit industry
standard 19” rack systems. The 1RU is listed to UL/CUL 1801
and designed to EN60950.
LDC1-Series:
19” or 23” One Rack Unit
The LDC1-Series One Rack Unit (1RU) saves
valuable real estate on a rack, while offering ease
of installation and service.
General Specifications
Standards:
Dimensions:
Enclosure:
Enclosure finish:
Feeds:
Load Connections:
Operating Voltage:
Alarm Feature:
LED indicators:
Chassis Ground:
The Carling circuit breakers installed in the 1RU are plug in
style to allow for hot swapability and front access, and are
rated to 50 amps per pole with a standard 10,000 amp interrupting capacity rating and a special 50,000 amp interrupting
capacity on request.
Even as a “condensed” panel, this new 1RU exceeds the
tough demands of today's applications while still offering safety, reliability and performance.
Features & Benefits
UL subject 1801 , CUL, TUV
Approved
CE approval pending
Rack mounts to EIA standard
EIA-310-D 19" rack for a 1RU
panel, 1.75"H.
16 gauge galvaneel steel
Powder coat, Gray
Dual feeds, rated up to 150
amps per feed.
Max. circuit breakers per feed: 6
Max. breaker rating: 50 amps.
Connections: single hole ring
terminal up to 2/0 awg
For 150 amps continuous max.
Requires 8 awg wire/ring or fork
terminal for 50 A/75° C Rating,
Top or bottom wire entry.
-36V to –60V DC
(-48VDC nominal)
Power alarm: If either A or B
FEED or both fail.
Breaker alarm: If any populated
breaker is OFF or “tripped.”
Alarm is not affected by unused
breaker positions.
LED indicators on the front panel.
Green lamps on A and B feeds.
Red lamp for tripped breaker
alarm indication.
Via studs on the back panel and
rack brackets to bare galvanized
metal on the distribution unit. Use
two hole x 5/8” center lugs.
•
•
•
•
•
•
•
•
•
•
•
Hot “swappable” circuit breakers that can be installed,
changed, or replaced in the field or factory.
Circuit breakers are front panel accessible.
Breaker removal tools available upon request for
installation and removal of circuit breakers.
Maximum of six UL489 listed circuit breakers per feed.
One Rack Unit (1RU) size.
Panel plugs provided for non populated circuit breaker
slots.
Short handle circuit breakers to prevent accidental
operation.
Panel is easily configurable and upgradeable in the
field. Provides flexibility when designing added
features or options.
Conserves valuable cabinet space to meet the tough
demands of today’s applications.
Consult factory or your local Carling Technologies
representative for any custom panel requirements.
Optional Rack Extenders to expand the panel
mounting from a 19” rack to a 23” rack.
Part Numbers:
8L1-A-DC1A (offset mounting)
8L1-A-DC1B (center mounting)
www.carlingtech.com
5
Carling
Technologies
LDC1-Series DC Secondary Power Distribution
™
LDC1-Series Ordering Scheme
- A L - 05 - 20 - 40 - 01 - 03 - 20 - A
LDC1
2
Breaker
Function
1
Series
5
Breaker in
Position 2
4
Breaker in
Position 1
3
Delay
1 SERIES
LDC1
6
Breaker in
Position 3
7
Breaker in
Position 4
4 through 9 BREAKER RATING
00
No breaker
01
1 amp
03
3 amps
05
5 amps
10
10 amps
15
15 amps
2 BREAKER FUNCTION
N
No breaker
A
Standard Trip
S
Mid-Trip
3 DELAY
N
No breaker
M
Medium Delay, Curve 14
L
Medium Delay, Curve 16
10 APPROVALS
A No approvals
G
10
Approvals
9
Breaker in
Position 6
8
Breaker in
Position 5
20
25
30
35
40
45
50
20 amps
25 amps
30 amps
35 amps
40 amps
45 amps
50 amps
UL/CUL
J UL/CUL, CE, TUV
NOTES:
Redundant feed. Breaker layout will be duplicated on the second feed.
Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed.
LDC1-Series Dimensional Specifications
CHASSIS GROUND LOCATION: 2X 1/4-20 STUDS
ON 5/8" (.625") CENTERS. BARE GALVANIZED METAL UNDER,
TO ACCEPT TWO-HOLE WIRE LUG.
17.71[449.8}
RETURNS ACCEPT SINGLE HOLE TERMINAL LUGS,
FOR LOADS UP TO 2/0 AWG FOR MAIN, UP TO 6 AWG
MAINS FEED BUS ACCEPTS SINGLE HOLE RING TERMINAL
UP TO 2/0 AWG CABLE. BUS RATED 150 AMP CONTINUOUS, MIN.
12.00 [304.8}
GREEN LED INDICTIONS FOR "POWER" ON A & B FEEDS
RED LED ALARM INDICATION FOR EITHER "TRIPPED" OR "OFF"
CONDITION ON ANY BREAKER; BREAKER POSITIONS
NOT POPULATED DO NOT CAUSE ALARM CONDITION
1.750 {44.45}
PANEL SUPPLIED CONFIGURED POPULATED WITH
SPECIFIC BREAKER RATINGS / POSITIONS.
UNPOPULATED POSITIONS SUPPLIED WITH PANEL
PLUGS. BREAKER RATINGS IDENTICAL FOR
A / B SIDES.
1.248 [31.7]
.251[6.38]
19.000 {482.6}
6
www.carlingtech.com
Carling
Technologies
LDC2-Series DC Secondary Power Distribution
™
To reduce space within Telecom cabinets without sacrificing
power, Carling Technologies has introduced a versatile 1RU
power distribution unit that combines GMT fuse protection with
hydraulic-magnetic circuit breaker protection. This new LDC2Series panel is designed to fit industry standard 23” rack systems.
The LDC2-Series panel features powerful dual feed redundancy for both the circuit breakers and the fuses. Hot “swappable”
design allows the panel to be field or factory configured, and
upgraded.
LDC2-Series:
23” One Rack Unit
The LDC2-Series One Rack Unit (1RU) combines
GMT fuse and Hydraulic/magnetic Circuit Breaker
Even in this compact package, this new LDC2-Series 1RU
panel exceeds the tough demands of today’s applications,
while offering safety, reliability and performance.
protection in one compact package.
General Specifications
Standards:
Dimensions:
Enclosure:
Feeds:
Load Connections:
Operating Voltage:
Alarm Feature:
LED indicators:
Chassis Ground:
Features & Benefits
UL subject 1801, CUL and TUV
Approved
CE approval pending
Rack mounts to EIA standard
EIA-310-D 23” rack for a 1RU
panel, 1.75” H.
16 gauge yellow zinc chromate
cold rolled steel
Dual feeds, rated up to 150
amps per feed.
Max. circuit breakers per feed: 6
Max. breaker rating: 50 amps.
GMT fuse feeds rated to 40A.
Max. GMT fuses per feed: 4
Max. fuse rating: 10A
Requires 1 awg wire/ring or fork
terminal for 25 A/75 C Rating,
Top or bottom wire entry.
For 50A load with 25A terminal,
fuse leads are through the
connector.
-36V to –60V DC
(-48VDC nominal)
Power alarm: If either A or B
FEED or both fail.
Breaker alarm: If any populated
breaker is OFF or “tripped.”
Alarm is not affected by unused
breaker positions.
LED indicators on the front panel.
Green lamps on A and B feeds.
Red lamp for tripped breaker
alarm indication.
Via studs on the back panel. Use
two hole X 5/8” center lugs. Via
Rack Mounting via brackets to
yellow zinc chromate steel panel
enclosure.
•
•
•
•
•
•
•
•
•
•
•
•
LDC2-Series incorporates Carling AC-Series
hydraulic/magnetic breakers, providing a superior level
of performance.
Versatile design combines circuit breaker and GMT
fuse protection in one panel.
Hot "swappable" circuit breakers that can be installed,
changed, or replaced in the field or factory.
Circuit breakers are front panel accessible.
Breaker removal tools available upon request for
installation and removal of circuit breakers.
Maximum of six UL489 listed circuit breakers per feed,
12 per panel.
One Rack Unit (1RU) size.
Panel plugs provided for non populated circuit breaker
slots.
Short handle circuit breakers to prevent accidental
operation.
Panel is easily configurable and upgradeable in the
field. Provides flexibility when designing added
features or options.
Conserves valuable cabinet space to meet the tough
demands of today’s applications.
Consult factory or your local Carling Technologies
representative for any custom panel requirements.
www.carlingtech.com
7
Carling
Technologies
LDC2-Series DC Secondary Power Distribution
™
LDC2-Series Ordering Scheme
LDC2
1
Series
- A L - 05 20 40 01 03 50 - A A A A - A
2
Breaker
Function
4
Breaker in
Position 1
3
Delay
5
Breaker in
Position 2
6
Breaker in
Position 3
1 SERIES
LDC2
2 BREAKER FUNCTION
N
No breaker
A
Standard Trip
S
Mid-Trip
3 DELAY
N
No breaker
M
Medium Delay, Curve 14
L
Medium Delay, Curve 16
12
Fuse in
Position 3
10
Fuse in
Position 1
11
Fuse in
Position 2
4 through 9 BREAKER RATING
00
No breaker
01
1 amp
03
3 amps
05
5 amps
10
10 amps
15
15 amps
20
25
30
35
40
45
50
20 amps
25 amps
30 amps
35 amps
40 amps
45 amps
50 amps
10 through 13 FUSE RATING
Z
Dummy Fuse
A
.25 amp
B
.50 amp
C
.75 amp
D
1 amp
E
1.5 amps
F
G
H
I
J
K
2 amps
3 amps
4 amps
5 amps
7.5 amps
10 amps
7
8
Breaker in Breaker in
Position 4 Position 5
9
Breaker in
Position 6
14 APPROVALS
A No approvals
G
UL/CUL
13
Fuse in
Position 4
J UL/CUL, CE, TUV
NOTES:
Redundant feed. Breaker layout will be duplicated on the second feed.
Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed.
GMT fuse feeds A & B are rated for 40 amps each. Total combined fuse ratings can not exceed 40 amps.
LDC2-Series Dimensional Specifications
MIDTRIP/STANDARD CIRCUIT BREAKER SELECTOR SWITCH
21.31 [541.2]
9.75 [247.7]
8.56 [217.4]
5.09 [129.3]
.54 [13.8]
.38 [9.5]
22.31[566.7]
.44 [11]
1.75 [44.5]
.87 [22.1]
.28 [7.1]
1.37 [34.7]
8
www.carlingtech.com
14
Approvals
Carling
Technologies
LDC1 & LDC2-Series Power Distribution Breakers
™
Circuit Breakers
Circuit breakers can be ordered separately to upgrade or reconfigure panel at a later date.
Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory.
General Specifications:
UL489, CSA and VDE approved
10,000 amp interrupting capacity
C-SERIES TIME DELAY VALUES
PERCENT OF RATED CURRENT
TRIP
Delay
100%
125%
150%
200%
400%
600%
800%
1000%
1200%
TIME
14
No trip
2.00-60.0
1.20-40.0
.600-20.0
.150-3.00
.030-1.30
.004-.600
.004-.100
.004-.100
(SECONDS)
16
No Trip
45.0-345
20.0-150
9.00-60.0
1.40-11.4
.150-5.80
.009-3.70
.005-1.70
.005-.500
MEDIUM DELAY, CURVE #14
STANDARD TRIP
10000
MID-TRIP with LDC1-Series
D.C.
MEDIUM DELAY
CURVE NO. 14
MID-TRIP with LDC2-Series
1
CA1-X0-09-031-AX1-MF
CS1-X0-09-032-AX1-MF
CT1-X0-09-032-AX1-MF
3
CA1-X0-08-981-AX1-MF
CS1-X0-08-992-AX1-MF
CT1-X0-08-992-AX1-MF
5
CA1-X0-08-982-AX1-MF
CS1-X0-08-993-AX1-MF
CT1-X0-08-993-AX1-MF
10
CA1-X0-08-983-AX1-MF
CS1-X0-08-994-AX1-MF
CT1-X0-08-994-AX1-MF
15
CA1-X0-08-984-AX1-MF
CS1-X0-08-995-AX1-MF
CT1-X0-08-995-AX1-MF
20
CA1-X0-08-985-AX1-MF
CS1-X0-08-996-AX1-MF
CT1-X0-08-996-AX1-MF
25
CA1-X0-08-986-AX1-MF
CS1-X0-08-997-AX1-MF
CT1-X0-08-997-AX1-MF
30
CA1-X0-08-987-AX1-MF
CS1-X0-08-998-AX1-MF
CT1-X0-08-998-AX1-MF
35
CA1-X0-08-988-AX1-MF
CS1-X0-08-999-AX1-MF
CT1-X0-08-999-AX1-MF
40
CA1-X0-08-989-AX1-MF
CS1-X0-08-000-AX1-MF
CT1-X0-08-000-AX1-MF
45
CA1-X0-08-990-AX1-MF
CS1-X0-08-001-AX1-MF
CT1-X0-08-001-AX1-MF
50
CA1-X0-08-991-AX1-MF
CS1-X0-08-002-AX1-MF
CT1-X0-08-002-AX1-MF
1000
100
TRIP TIME IN SECONDS
RATING (amps)
10
1
.1
.01
.001
100
125
200
300
150
MID-TRIP with LDC1-Series
600
700
800
900
1000
1100
1200
D.C.
LONG DELAY
CURVE NO. 16
MID-TRIP with LDC2-Series
1
CA1-X0-08-561-AX1-MF
CS1-X0-09-033-AX1-MF
CT1-X0-09-033-AX1-MF
3
CA1-X0-07-803-AX1-MF
CS1-X0-09-003-AX1-MF
CT1-X0-09-003-AX1-MF
5
CA1-X0-07-804-AX1-MF
CS1-X0-09-004-AX1-MF
CT1-X0-09-004-AX1-MF
10
CA1-X0-07-805-AX1-MF
CS1-X0-09-005-AX1-MF
CT1-X0-09-005-AX1-MF
15
CA1-X0-07-806-AX1-MF
CS1-X0-09-006-AX1-MF
CT1-X0-09-006-AX1-MF
20
CA1-X0-07-807-AX1-MF
CS1-X0-09-007-AX1-MF
CT1-X0-09-007-AX1-MF
25
CA1-X0-07-645-AX1-MF
CS1-X0-09-008-AX1-MF
CT1-X0-09-008-AX1-MF
30
CA1-X0-07-646-AX1-MF
CS1-X0-09-009-AX1-MF
CT1-X0-09-009-AX1-MF
35
CA1-X0-07-808-AX1-MF
CS1-X0-09-010-AX1-MF
CT1-X0-09-010-AX1-MF
40
CA1-X0-07-809-AX1-MF
CS1-X0-09-011-AX1-MF
CT1-X0-09-011-AX1-MF
45
CA1-X0-07-810-AX1-MF
CS1-X0-09-012-AX1-MF
CT1-X0-09-012-AX1-MF
50
CA1-X0-07-811-AX1-MF
CS1-X0-09-013-AX1-MF
CT1-X0-09-013-AX1-MF
1000
100
TRIP TIME IN SECONDS
STANDARD TRIP
500
10000
LONG DELAY, CURVE #16
RATING (amps)
400
PERCENT OF RATED CURRENT
10
1
.1
.01
.001
100
125
200
300
150
400
500
600
700
800
900
1000
1100
1200
PERCENT OF RATED CURRENT
Circuit Breakers Dimensional Specifications
.500 [12.67]
±.060
TYP-OPTIONAL
"ON-0FF", I-O
LEGEND
SHORT HANDLE CIRCUIT BREAKER REQUIRES NO HANDLE GUARD,
HAS MINIMAL HANDLE PROTRUSION IN "ON" AND "OFF" POSITION
±1.52
2.810 [71.38] TYP
.406 [10.31]
1.850 [47.00] TYP
LINE
ON
I
.960[24.38]
.640 [16.26]
.930 [23.62]
C
1.220 [30.98] 2.500 [63.50] TYP
NO
60°
1.438 [36.53]
OFF
O
.558[14.17]
CENTERLINE OF
PUSH-IN STUD
CONTACT AREA
NC
30°
±.020
±.51
1.940 [49.28] TYP
F
OF
O
.755 [19.18] MAX.
.135 [3.42]
.150 [3.81]
TYP.
LOAD
±.020
±.51
.273 [7.14] TYP
PUSH-IN STUD DETAIL
2.250 [57.15] TYP
#6-32 [M3] THREAD X .195 [4.95] DEEP
(2 PLCS) / POLE
www.carlingtech.com
9
Carling
Technologies
LAC1-Series Telecom AC Power Distribution Panel
™
LAC1-Series:
Telecom AC PDC
The LAC1-Series AC PDC provides custom
configurations in a standard format.
The LAC1-Series eliminates the need to invest in custom
designed AC power requirements. The LAC1-Series is a standard AC load center designed for today’s Telecommunications
requirements, and is available from 120-240VAC.
General Specifications
Standards:
Dimensions:
Enclosure:
Mains Breaker:
Loads:
Service Outlet:
Operating Voltage:
Service Entry:
Load Center Breakers:
10
Features & Benefits
UL67 Listed for AC Panelboards
Wall mount enclosure.
20”W x 14”H x 3.84”D
16 gauge cold rolled steel with a
powder coat finish.
2-pole 100 amp mains breaker,
120/240 vac, 50-60 Hz, & 2-pole
100 amp generator back-up
breaker, tied together, but with
independent operation. Slide-bar,
lock-out feature allows transfer
from AC to generator power.
Slots for up to 13 poles of branch
circuit breakers.
Circuit breakers 1-4: reserved for
2-pole breakers.
Circuit breakers 5-6: reserved
for one, 2-pole breaker or two
single pole breakers.
Circuit breaker 7: reserved for a
2-pole 15A circuit breaker
(preloaded) for the GFI service
outlet & optional surge
suppressor.
Circuit breaker 8: reserved for a
single pole circuit breaker
15 Amp, 120VAC GFI
120/240VAC, or 120/208V @
50/60 Hz, 70 Amps single phase.
Service Entry fittings located at
the bottom, and bottom right
corner of the enclosure.
UL489 C-Series w/ clip terminals
& maximum rating of 50 amps
per position with a total per panel
of 70 amps or less.
•
•
•
•
•
•
•
•
•
•
•
•
•
Versatile design allows custom configurations of
branch circuits based on individual applications.
Circuit breakers snap-in to Carling Technologies’
exclusive circuit breaker mounting block. No need to
hard wire the circuit breakers.
Easy change over from main to generator power by
use of a slide bar.
UL listed to UL67 for AC panel boards.
GFI convenience outlet is included for service.
AC panel was designed for easy wiring.
Ordering scheme assists you in ordering a custom
solution from a standard product. Individual circuit
breaker part numbers are provided which allow you
to easily upgrade your existing panel in the future.
Front cover is easily removed.
Handleguards protect breakers.
Breaker handles are visible through the front cover of
the panel to allow easy breaker status identification .
Breaker state can be changed without opening panel.
Branch Circuits protected by Carling C-Series UL489
hydraulic/magnetic listed, VDE approved breakers,
with clip terminals that allow easy snap-in mounting of
breakers into the AC panel.
Breaker trip and Current ratings are unaffected by
ambient temperatures.
www.carlingtech.com
Carling
Technologies
LAC1-Series AC Power Distribution
™
LAC1-Series Ordering Scheme
LAC1
- 05 05 05 20 - 1 10 1 10 - 15 - 15
1
Series
2
Breaker in
Position 1
3
Breaker in
Position 2
4
Breaker in
Position 3
5
Breaker in
Position 4
1 SERIES
LAC1
2 through 5 TWO POLE BREAKER RATING
00
No breaker
20
20 amps
05
5 amps
25
25 amps
10
10 amps
30
30 amps
15
15 amps
35
35 amps
40
45
50
40 amps
45 amps
50 amps
7
6
8
# Poles in Breaker in # Poles in
Position 5 Position 5 Position 6
9
Breaker in
Position 6
7 and 9 BREAKER RATING
00
No breaker
20
05
5 amps
25
10
10 amps
30
15
15 amps
35
10
Breaker in
Position 7
20 amps
25 amps
30 amps
35 amps
40
45
50
40 amps
45 amps
50 amps
40
45
50
40 amps
45 amps
50 amps
10 TWO POLE BREAKER RATING
15
15 amps
11 SINGLE POLE BREAKER RATING
00
No breaker
20
20 amps
05
5 amps
25
25 amps
10
10 amps
30
30 amps
15
15 amps
35
35 amps
6 and 8 NUMBER OF POLES1
0
No breaker
1
single pole
2
two pole
11
Breaker in
Position 8
NOTES:
1
If choosing single pole breakers, you must choose breakers for both positions 5 and 6.
If choosing a two pole breaker in position 5, then position 6 (selected in fields 8 and 9) must be “no breaker”.
LAC1-Series Dimensional Specifications
www.carlingtech.com
11
Carling
Technologies
LAC1-Series AC Power Distribution
™
Circuit Breakers
Circuit breakers can be ordered separately to upgrade or reconfigure panel at a later date.
Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory.
General Specifications:
UL489, CSA and VDE approved
10,000 amp interrupting capacity
C-SERIES TIME DELAY VALUES
TRIP
PERCENT OF RATED CURRENT
TIME
Delay
100%
125%
135%
150%
200%
400%
600%
800%
1200%
(SECONDS)
24
No trip
10.0-160
-
.600-60.0
2.20-20.0
.300-3.00
.050-1.30
.007-.500
.005-.040
MEDIUM DELAY, CURVE #24
10000
SINGLE POLE
TWO POLE
5
CA1-X0-09-250-C2X-KG
CA2-X0-09-244-C2X-CG
10
CA1-X0-06-604-C2X-KG
CA2-X0-07-169-C2X-CG
15
CA1-X0-09-251-C2X-KG
CA2-X0-08-169-C2X-CG
20
CA1-X0-06-606-C2X-DJ
CA2-X0-04-891-C2X-CG
25
CA1-X0-09-252-C2X-KG
CA2-X0-09-245-C2X-CG
30
CA1-X0-09-253-C2X-KG
CA2-X0-06-299-C2X-CG
35
CA1-X0-09-254-C2X-KG
CA2-X0-09-246-C2X-CG
40
CA1-X0-09-255-C2X-KG
CA2-X0-09-247-C2X-CG
45
CA1-X0-09-256-C2X-KG
CA2-X0-09-248-C2X-CG
50
CA1-X0-09-261-C2X-KG
CA2-X0-09-249-C2X-CG
50/60 Hz
MEDIUM DELAY
CURVE NO. 24
1000
TRIP TIME IN SECONDS
RATING (amps)
100
10
1
.1
.01
.001
100
200
300
400
500
600
700
800
125
150
Circuit Breakers Dimensional Specifications
12
www.carlingtech.com
PERCENT OF RATED CURRENT
900
1000
1100
1200
Carling
Technologies
LBD-Series Battery Disconnect Panel
™
The LBD-Series battery disconnect panels were designed with
performance, style and size in mind. Carling Technologies has
packed this product line with ratings up to 700A, interrupt
capacity of 50,000A, PDC voltage ratings of -36 to -60 VDC
and in sizes starting as small as 1 rack unit (1RU) x 19”, up to
3RU.
LBD-Series:
Battery Disconnect Panels
The LBD-Series addresses the demanding requirements associated with today’s Telecommunication Networks.
The LBD-Series Battery Disconnect Panels provide battery
protection in rack mount and enclosure style while freeing
up valuable real estate within your cabinet.
General Specifications
Standards:
Dimensions:
Enclosure:
Current Ratings:
Circuit Breaker
Voltage Ratings:
Interrupting Capacity:
Alarm Feature:
Ambient Temperature:
LED indicators:
Rack Mount Insulators:
Meter Shunt Option:
Chassis Ground:
Lug Connections:
Lugs Required:
Features & Benefits
UL Listed
Rack mounts to EIA standard
EIA-310-D, 1-3RU,
19” or 23” panel
14 gauge Galvaneel steel w/
powder coat finish, & Bare metal
ground.
250 amps/ 1RU;400 amps/2RU
700 amps/3RU
125 vdc
50,000 amps @ 60 vdc
Std. 1 form C contact for power
ON/OFF, 1 form C, Contact for
breaker OFF/TRIPPED.
-40°C to +60°C
Green lamp for power indication.
Red lamp for alarm indication.
UL94V-0 material over all live
parts.
Optional meter shunt provides
25m V at rated current.
Bare metal to rack mount flange
& 1/4 - 20 stud to bare metal.
Busbars accept 2-hole std.
telecom lugs up to 750 mcm
cable. 1 lug-up to 250 amps; 2
lugs-up to 400 amps; 3 lugs- up
to 700 amps. Lugs can be
mounted on either or both sides.
Lugs can be through bolted on
each side of the bus bar, doubling
lug capacity.
1.75” hole spacing, 1/2: bolt lug,
max. 1.75” wide
•
•
•
•
•
•
•
•
•
•
Panel incorporates Carling F-Series high amperage
hydraulic/magnetic breakers: providing a superior level
of performance.
Each panel is sized for maximum protection in the
smallest size possible to conserve valuable cabinet
space. Starting with a compact 1RU x 19” rack rated up
to 250 amps @ 60 vdc with a 50,000 AIC.
Front panel access.
Insulator covers are standard to protect live parts once
the panel is installed.
Front panel is provided with a circuit breaker handle
guard to protect from unintentional operation.
LED indications are standard for visual monitoring.
The LBD provides, as a standard, a circuit breaker
alarm feature to alert breaker trip or off conditions.
Voltage, or current monitoring, and remote shut down
options are offered.
Cable connections on thick silver plated, copper
busbars, which accept standard 2-hole telecom lugs
from 1 AWG to 750 MCM sizes.
Lugs can be mounted on either or both sides of the bus
bars.
www.carlingtech.com
13
Carling
Technologies
LBD-Series Battery Disconnect Panels
™
LBD-Series Ordering Scheme
LBD P 1
1
Series
2
Style
- 1 - 810 - A - A - 0 - 0 - A
3
Rack Size
4
Function
5
Current Rating
1 SERIES
LBD
E
2
4 FUNCTION
Switch Only
0
1
Series Trip
5 CURRENT RATING
810 100 amp (1RU)
820 200 amp (1RU)
7
Metering
Shunt
6 BUS BAR TYPE
figure 1
A
2 STYLE
Rack Mount
P
3 RACK SIZE
19” rack
1
6
Bus Bar
Type
23” rack
E
2
3
825
840
Enclosure/Wall Mount
250 amp (1RU)
400 amp (1RU)
Enclosure
Series Trip with Aux. Switch
Mid-trip with Alarm Switch
860
870
600 amp (1RU)
700 amp (1RU)
10
Approvals
9
Special
Options
B
figure 1 w/ PEM studs
7 METERING SHUNT
0 No shunt
A
Metering shunt
8 REMOTE DISCONNECT VOLTAGE
0 No remote option
A 24 vdc
B 48 vdc
C 120 vdc
D 240 vdc
9 SPECIAL OPTIONS
0 None
X
Consult factory
10 APPROVALS
A No approvals
B
UL Listed
NOTES:
Circuit breakers are provided with a DC medium delay curve.
1
Current & voltage monitoring are available as special options. Select X in position 9, and advise factory.
LBD-Series Rack Mount Dimensional Specifications
14
8
Remote
Disconnect
Voltage
www.carlingtech.com
Carling
Technologies
LBD-Series Battery Disconnect Panels
™
LBD-Series Wall Mount Dimensional Specifications
Circuit Breakers
Circuit breakers can be ordered separately to
upgrade or reconfigure panel at a later date.
Standard circuit breaker part numbers are listed
on the chart below. For other ratings, consult
factory.
F-SERIES TIME DELAY VALUES
TRIP
PERCENT OF RATED CURRENT
TIME
Delay
100%
125%
150%
200%
400%
600%
800%
1200%
(SECONDS)
14
No trip
10.0-110
.600-40.0
2.50-15.0
.500-3.00
.180-1.00
.010-.280
.008-.080
10000
D.C. MEDIUM DELAY
CURVE NO. 14
General Specifications:
UL489, CSA and VDE approved
10,000 amp interrupting capacity
1000
TRIP TIME IN SECONDS
100
10
1
.1
.01
.001
100
125
200
300
400
500
600
700
800
900
1000
1100
1200
150
PERCENT OF RATED CURRENT
www.carlingtech.com
15
Carling
Technologies
Power Distribution Accessories
™
Panel Hole Plug
809-70194-001
1 Part Number
1 PART NUMBER
809-70194-001
809-70194-002
LAC1 Snap-In Panel Plugs
LDC1 & LDC2 Snap-In Panel Plugs
C-Series with Push-In Stud Terminals Mounting Kit & Removal Tool
Circuit Breaker
Removal Tool
8C1-X0-08-639
1 Part Number
1 PART NUMBER
8C1-X0-08-639
8C1-X0-09-593
8C1-X0-07-628
Removal Tool for 6-32 inserts
Removal Tool for M3 inserts
Mounting kit for one circuit breaker position (includes mounting block, bullet sockets, aux. switch,
PC board connectors, aux. switch connector housing and two screws. Bus bar and PCB are not
included in the mounting kit.)
C-Series Circuit Breaker Module for DC Power Distribution
L0053
1 Part Number
1 PART NUMBER
L0053
8C1-X0-08-573
Circuit Breaker Module
• Six position circuit breaker module, individual circuit breaker slot rated to 100amps
• Hot swappable plug-in circuit breakers
• UL489 listed hydraulic/magnetic circuit breakers available for the module
• Breaker alarm circuit
• 300 amp line bus
• Custom mounting block allows for Load bus to easily change
• Building block design allows for easy changes
Circuit Breaker Module Kit for individual loads (includes mounting block, auxiliary switch housing,
rivet, two screws, two push-in terminal receptacles and three .110QC terminal receptacles.)
C-Series Circuit Breaker AC Plug-In Bracket
PR8080-667
1 Part Number
1 PART NUMBER
PR8080-667
16
C-Series Circuit Breaker AC Plug-In Bracket
www.carlingtech.com
Carling
Technologies
Custom Power Distribution Solutions
™
Custom Power Distribution Solutions
Carling Technologies offers expertise in electrical and mechanical design, tooling, prototyping, testing, and manufacturing. At
Carling we do much more than manufacture standard products. Our dedicated PDC team provides innovative design and
skillfully engineered power distribution solutions to meet
today's demanding custom requirements. We work closely with
your engineering team to meet your application requirements
and exceed your expectations.
Let the Carling PDC team design and develop a custom
Power Distribution Center or Battery Disconnect Panel that will
meet your special requirements. Please take a moment to
browse through our PDC photo galleries and view some
examples of our custom design & solution capabilities. Then
contact us today and let us assist you with your custom
designs.
Custom Battery Disconnect Gallery
L0054
• Battery disconnect for single battery
string
• Mounts directly to a battery
housing
• Connections made by Anderson
Connectors
• UL489 Listed hydraulic/magnetic circuit breaker
• Circuit breaker rating 100A @ 80VDC with a 50,000 AIC
L0059
• Battery Disconnect for multiple
battery strings
• Two UL489 Listed hydraulic/
magnetic circuit breakers, one to
disconnect an individual battery string, one to disconnect the
entire battery system
• Breakers are rated for 100 amps @ 80VDC with 50,000 AIC
• Panel attaches directly to a battery compartment
• Connections made with Anderson Connectors
Custom AC Gallery
L0005
• 100 amp rating
• 208-420VAC
• UL489 listed hydraulic magnetic
circuit breakers
• Optional surge suppressor
4-115V convenience outlets, GFI
& non-GFI protected 4-250V twist lock
• Designed for UL50
L0066
• 23" rack mount design
• 100 amp 3 pole UL489 listed
Mains circuit
breaker
• 16 slots for plug-in circuit breakers
• Rocker style branch circuit breaker
with rocker guard and visual trip indication
• Hydraulic magnetic circuit breakers
• Power strip top for a variety of outlets
L0069 Remote Power Management
• Independent circuit breakers
controlled remotely via your
phone
• RPMS calls an assigned
phone number when a breaker
has tripped, & allows you to
service or reset the breaker over
the phone
• Dial up feature allows you to
change breaker states as
needed
L0081
• UL67 listed for AC panelboards
• Wall mount enclosure
• 70A 2 pole Mains breaker,
with 2 pole 70A generator
back-up breaker tied together
but operating independently
• Slide bar lock out allows
transfer slots for up to 13 poles of branch circuit breakers
• UL489 listed hydraulic/magnetic breakers with handle guards
• 15 amp GFI service outlet
• Circuit breakers visible through front cover
L0118
• Compact wall mount design
• 2 pole circuit breaker for rectifiers
• 1 pole circuit breaker for battery heater
• 1 pole circuit breaker for GFI outlet
• GFI service outlet
• Battery heater outlet
• UL489 listed hydraulic/magnetic breakers with
handle guards
• Designed for UL67
L0125
• Compact wall design
• 30A 3 pole Mains breaker
with 3 pole generator
back-up breaker tied
together but operating
independently - slide bar lock out allows transfer
• Slots for up to 10 poles of branch circuit breakers
• UL489 listed hydraulic magnetic circuit breakers
www.carlingtech.com
17
Carling
Technologies
Custom Power Distribution Solutions
™
Custom DC Gallery
L0039 - Alarm Panel
• 23" rack mount alarm
panel, with front handles
for easy mounting,
thumb screws for easy access
• Ability to monitor up to 144 circuit breaker positions, DC volt
monitoring display, DC amp monitoring display
• Audible alarm mute feature
• Front access fuse protection, voltage & amp monitoring
front access plugs
• 2 surge suppressors,15 amp GFI Service outlet
• Entry for large generator connector
L0039 - High Power PDC
• 23" rack mount design
• 48 circuit breaker position
panel
• Hot swappable UL489
Listed hydraulic/magnetic
breakers
• Mid-trip alarm indication
• Ratings up to 100 amps
per slot
• 800 amp bus
L0056
• 23" rack mount panel
with hinged front
cover, designed for
UL1801
• 16 poles available for
hot swappable plugin circuit breakers
• UL489 Listed mid-trip hydraulic magnetic circuit breakers
with handle guards
• 20 position GMT fuse panel
• 800 amp LOW VOLTAGE DISCONNECT
• Front access alarm and load connections
• Visual alarm and power indicators
L0074
• 23" rack mount DC distribution
panel
• 3 rack units tall
• Redundant feeds
• 5 circuit breakers per feed
• Front access alarm connection
• Hot swappable UL489 Listed hydraulic/magnetic breakers
• Powder coat finish
• Open back for easy access
L0078
• 19" rack mount DC panel
• Dual feed
• Four circuit breakers per feed
• 200 amp rating per feed
• Alarm monitoring: Major, Minor, Critical
• Power indicator
• UL489 Listed hydraulic/magnetic rocker style breakers with
visual trip indication and rocker guards
• Designed for UL1801 and NEBs
L0082
• 1 rack unit tall
(1.75") for a 23"
rack
• Dual feed
• 6 hot swappable plug-in
circuit breakers, 300A rating
per feed
• Dual feed GMT fuse panel, 4 fuses per feed
• UL489 Listed hydraulic/magnetic mid-trip circuit breakers
with short handle design to hinder unintentional operation
• Extended top cover over the front of panel for added
protection
• Rear insulator
• UL1801 and CSA approved
L0105
• 1 rack unit tall (1.75") for a
19" rack
• Dual feed
• Each feed consists of 2 hot swappable plug-in breakers and
10 GMT fuses
• 50A max rating per breaker
• 10 amp max rating per GMT fuse
• Removable alarm card
• Visual alarm indications: Major, Minor, Critical Power
indicator
• UL489 Listed hydraulic magnetic rocker style circuit
breakers with rocker guard & visual trip indicator
Warranty Policy
Carling Technologies, Inc. (Seller) warrants that goods sold hereunder shall be free of defects in material and workmanship for one year from date of
shipment.
In the event of such defects, the Seller’s only obligation shall be the replacement or the cost of the defective goods, themselves, excluding, without limitation, labor costs, which are or may be required in connection with the replacement or reinstallation of the goods. This warranty is the Seller’s sole
obligation and excludes all other remedies or warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described herein. This Warranty expressly excludes any and all incidental, special and/or consequential damages of any nature. Seller further disclaims any responsibility for injury to person or damage to or loss of property or value caused by
any product which has been subjected to misuse, negligence, or accident; or misapplied, or modified or repaired by a person or persons not authorized
by the Seller or which have been improperly installed.
18
www.carlingtech.com
Carling
Technologies
Power Distribution Project Design Form
™
Carling Technologies
Power Distribution
Project Design Form
™
Innovative Designs. Powerful Solutions.
*** Please fax completed forms to 860-793-9231 or email to: [email protected] ***
PROJECT INFORMATION:
Index Number:
Submittal Date:
Sales Representative:
Phone/email:
Rep. Company:
Region Manager:
CUSTOMER INFORMATION:
Company Name:
Date of Non-Disclosure:
Address:
City, State, ZIP:
Engineering Contact:
Title:
Phone:
Fax:
email:
Purchasing Contact:
Title:
Phone:
Fax:
email:
APPLICATION INFORMATION:
Acceptable electronic files:
IGS
DXF
Application:
DWG
PDF
STEP
other:
EAU Year 1:
EAU Year 2:
EAU Year 3:
# of prototypes:
Pilot Production Schedule:
Schematic Available?:
Product Life:
Project Value:
Redesign Details:
Specifications Available?:
New Product Details:
Development Budget Limitations:
Existing Sample Available?:
Target Price:
Target Price:
SPECIFICATIONS:
Open/Closed Frame:
AC/DC Voltage:
For DC, Rack Type:
Operating Voltage Tolerance:
Enclosure Dimensions:
19":
23":
Mains Feed Amps:
Number of Breakers:
If necessary, add additional information to notes section below, or attach second sheet.
Type of Trip Indication Alarming Required:
AGENCY APPROVALS:
UL
UL STD
CUL
TUV
CE
Other:
COMPETITIVE INFORMATION:
Competition:
Competitors Part Number:
Current Price:
NOTES AND ACTION ITEMS:
www.carlingtech.com
19
Carling
Technologies
20
Notes
™
www.carlingtech.com
Other Carling Technologies Catalogs
Thermal Circuit Protectors
Circuit Protection
This catalog details
This catalog details
Carling’s thermal cir-
the complete line of
cuit protection prod-
Carling circuit protec-
ucts. Thermal pro-
tion products includ-
tectors range from
ing hydraulic/mag-
0.1 to 40 amps.
netic circuit breakers
Front Panel Snap-in
and ground fault
Mounting styles and
breakers. Breakers
Quick Connect
range from 0.1 to
Terminals are includ-
700 amps Hi-inrush
ed. Worldwide certifications, including UL1500,
delay curves, Front Panel Snap-in Mounting styles,
TUV and CE marked.
Rockerguard Bezels, Dual-Coil functions, and Quick
Connect Terminals are included. Worldwide certifications, including UL1500, UL489 and CE marked.
Digital Switching Systems
Switches and Electronic Controls
This catalog includes
This catalog details
the complete line of
Carling’s Digital
Electronic Controls
Switching System:
and Carlingswitch
the ECS III. The ECS
brand electrical
III (Electronic Control
switches for most
System), features
any power switching
the latest in digital
need. Included are
multiplex technology,
dimmer, wiper, and
creating a safer and
mirror rotate controls, along with rocker, toggle, pushbutton, rotary
and sealed switches with a wide variety of circuits,
ratings, terminations, colors, illuminations, and legends. Worldwide certifications, UL1500, CE marked.
fully configurable
control system for the marine environment. The
ECS III eliminates complex wiring while increasing
switching features and functionality, and simplifying
troubleshooting.
www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc., Connecticut, USA
(860) 793-9281, fax: (860) 793-9231
e-mail: [email protected]
www.carlingtech.com
Eastern U.S. and Eastern Canada:
(860) 586-8413, fax: (860) 586-8513
e-mail: [email protected]
Midwestern U.S.:
(815) 653-9333, fax: (815) 653-2206
e-mail: [email protected]
Western U.S., Western Canada, Mexico
and South America:
(972) 509-0807, fax: (972) 509-0368
e-mail: [email protected]
Europe/Middle East/Africa Headquarters
Carling Technologies Ltd., Devon, England
Int + 44 1392-364422, fax: Int + 44 1392-364477
e-mail: [email protected]
Central Europe:
Carling Technologies GmbH
Int + 49 6104-959157, fax: Int + 49 6104-959158
e-mail: [email protected]
Southern Europe:
Carling Technologies SARL
Int + 33 3 84 43 0706, fax: Int + 33 3 84 43 14 44
e-mail: [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277, fax: Int + 852-2736-9332
e-mail: [email protected]
China
Int + 86-21-6390-6916, fax: Int + 86-21-6390-6918
e-mail: [email protected]
Japan
Int + 813-5789-2925, fax: Int + 813-5789-2927
e-mail: [email protected]
PD_7_03