Power Distribution AC & DC Power Distribution and Battery Disconnects Carling Technologies Introduction to Power Distribution ™ With over 80 years of experience in the development of power switching and protection components, Carling Technologies offers standard and custom designed AC and DC power distribution centers that provide the utmost in safety, reliability and performance. Power Distribution Center, or PDC, is Carling's term for a standard or custom power distribution panel or unit that's factory wired and contains overcurrent and short circuit protection devices. It may also contain auxiliary devices such as surge suppressors, ground fault circuit interrupters, power receptacles, etc. A PDC is usually supplied by the main feeder and then divides the power into smaller branch circuits. A PDC provides the required circuit control and overcurrent protection needed to all the circuits and the loads connected to it. Power Distribution Unit, or PDU, is an industry term for horizontally mounted panels used in 19” or 23” racks. Carling Technologies’ expertise in custom design solutions, tooling, manufacturing, and our broad customer base has allowed us to develop a high quality standard product line of power distribution centers. Our standard PDU and PDC products have been designed to meet today's demanding global industry standards, taking into account the growing need to reduce the amount of real estate that panels require, without sacrificing power. In addition, our dedicated engineering team designs and develops custom Power Distribution Centers or Battery Disconnect Panels that will meet your special requirements. Utilizing a comprehensive range of quality circuit protection and control products, you can specify the physical size of the enclosure and add your component requirements including temperature stable Carling Technologies' hydraulic-magnetic circuit breakers, ground fault circuit protectors, transient voltage surge suppressors, meters, power receptacles, relays, bus bars, hole plugs and LED's. For the Telecommunication, Server, Marine, Generator, Alternative Power, and Medical industries, Carling Technologies' expertise in power distribution and electrical design can help you meet your power needs. Contact us with your requirements today. CHARGER/ RECTIFIER DC DISTRIBUTION DC LOAD LDC1, LDC2 & LDM1-Series DC LOAD CHARGER/ RECTIFIER DC DISTRIBUTION AC DISTRIBUTION BATTERY DISCONNECT BATTERY DISCONNECT DC LOAD DC LOAD LDC1, LDC2 & LDM1-Series LBD-Series ˜ UTILITY POWER ˜ LAC1-Series LBD-Series ALARM/MONITOR BATTERY BANK A BATTERY BANK B L0039 GENERATOR (BACK-UP) Block Diagram illustrating a typical telecommunications power distribution circuit featuring Carling Technologies PDU and PDC products. The Power Distribution circuit can be fed by utility power on a back-up generator. In addition, battery power can be supplied and controlled with Carling Technologies Battery Disconnect PDU’s. The DC Power Distribution can be monitored by Carling Technologies Alarm/Monitor PDU. www.carlingtech.com Carling Technologies Contents ™ Carling Technologies’ Products Within this catalog, you’ll find a comprehensive line of AC & DC Power Distribution Units (PDU’s), AC Power Distribution Centers (PDC’s), and Battery Disconnect Panels for the Telecom market. All DC products are designed to fit into industry standard 19” and 23” racks, from 1RU to 3RU, and utilize Carling hydraulic/magnetic breakers. We also offer custom power distribution products, hydraulic/ magnetic circuit breakers, thermal circuit protectors, switches, electronic controls and digital switching systems. For more information on these products, please request one of the catalogs listed on the inside back cover of this catalog, or go to www.carlingtech.com. How To Use This Catalog Please refer to the Product Selector Guide, located on this page, for the type of PDC required. Product features/specifications and dimensional drawings are provided to assist you with product selection. Follow our easy, step-by-step, catalog number sequence to construct the PDC which meets your needs. An example for constructing a catalog number is provided for each Series. Customer Care Center For additional application assistance, we urge you to consult with our experienced staff in our Customer Care Center. Our Technical and Engineering staff has extensive test, research and development capabilities, and have assisted many customers in solving unique design and application problems with standard or customized products. Please refer to our location listing on the back of this catalog for contact information for your area. We look forward to working with you. Power Distribution Product Selector Guide Type # Circuits # Circuits protected by protected by Circuit Bus Circuit breaker GMT fuse Current Current Voltage Alarm Mounting Size Page Series LDM1-Series DC Dual Feed PDU 18 total (9 per feed) _ 25A max 150A 36 to 60 per feed (- DC) Yes 19" or 23" 1RU rack 2 12 total (6 per feed) _ 50A max 150A 36 to 60 per feed (- DC) Yes 19" or 23" 1RU rack 5 12 total (6 per feed) 8 total (4 per feed) 50A max 150A 36 to 60 per feed (- DC) Yes 23" rack 1RU 8 13 poles _ 50A max No Vertical _ 10 LDC1-Series LDC2-Series LAC1-Series AC PDC LBDP-Series Battery Disconnect LBDP1 1 up to 250A 250A LBDP1 1 up to 400A 400A LBDP3 1 up to 700A 100A 1RU 19" rack 700A _ _ LBDP1 1 up to 250A 250A LBDP1 1 up to 400A 400A LBDP3 1 up to 700A 700A 120/240 AC 125 VDC max 2RU 3RU No 13 Vertical _ Accessories 16 Custom Power Distribution Solutions 17 Power Distribution Project Design Form 19 www.carlingtech.com 1 Carling Technologies LDM1-Series DC Secondary Power Distribution ™ To help conserve valuable cabinet space, Carling Technologies introduces a new, advanced 1RU DC Power Distribution Unit (PDU) for the telecom industry. This new PDU is designed to fit industry standard 19” rack systems. This 1RU is listed to UL/CUL 1801 and designed to EN60950. LDM1-Series: 19” or 23” One Rack Unit The LDM1-Series One Rack Unit (1RU) saves valuable real estate on a rack, while offering ease of installation and service. General Specifications Standards: Dimensions: Enclosure: Feeds: Load Connections: Operating Voltage: Alarm Feature: LED indicators: Chassis Ground: 2 The Carling circuit breakers installed in the 1RU are the miniature M-Series hydraulic-magnetic breakers — the smallest breaker on the market that is UL489A listed up to 80 VDC. In addition, these breakers are plug in style to allow for hot “swappable” and front access, and are rated to 25 amps per pole. Even as a “condensed” panel, this new 1RU exceeds the tough demands of today's applications while still offering safety, reliability and performance. Features & Benefits UL 1801, CUL Approved Rack mounts to EIA standard EIA-310-D 19" rack for a 1RU panel, 1.75"H. 16 gauge yellow zinc chromate cold rolled steel. Dual, rated up to 150 amps per feed. Max. circuit breakers per feed: 9 Max. breaker rating: 25 amps. Connections: two hole compression lugs for 1/4 - 20 stud terminals x 5/8 centers. Requires 10 awg wire/ring or fork terminal for 25 A/75 C Rating, Top or bottom wire entry. -36V to –60V DC (-48VDC nominal) Power alarm: If either A or B FEED or both fail. Breaker alarm: If any populated breaker is OFF or "tripped." Alarm is not affected by unused breaker positions. LED indicators on the front panel. Breaker slots can be set or deactivated on the removable Alarm Card. Green lamps on A and B feeds. Red lamp for tripped breaker alarm indication. Via studs on the back panel. Use two hole X 5/8" center lugs. Grounding is also achieved through the rack mounting brackets to the yellow zinc chromate steel panel enclosure. • • • • • • • • • • • • Panel incorporates Carling M-Series style hydraulic/magnetic breakers: The smallest UL489A listed hydraulic-magnetic circuit breaker on the market today! Keyed terminal to prevent breaker from being mounted incorrectly. Hot “swappable” circuit breakers that can be installed, changed, or replaced in the field or factory. Circuit breakers are front panel accessible. Maximum of 9 circuit breakers per feed; 18 per panel. One Rack Unit (1RU) size. Panel plugs provided for non populated circuit breaker slots. Rockerguard circuit breakers to prevent accidental operation. Panel is easily configurable and upgradeable in the field. Provides flexibility when designing added features or options. Conserves valuable cabinet space to meet the tough demands of today’s applications. Front accessible removable alarm card. Optional Rack Extenders to expand the panel mounting from a 19" rack to a 23" rack. Part Numbers: 8L1-A-DC1A (offset mounting) 8L1-A-DC1B (center mounting) www.carlingtech.com Carling Technologies LDM1-Series DC Secondary Power Distribution ™ LDM1-Series Ordering Scheme LDM1 - B M - 05 20 10 01 03 25 15 H7 20 1 Series 2 Rocker Style 4 Breaker in Position 1 3 Delay 5 Breaker in Position 2 6 Breaker in Position 3 7 Breaker in Position 4 1 SERIES LDM1 2 ROCKER STYLE N No breaker B Black with white legend 3 DELAY N No breaker 8 Breaker in Position 5 9 Breaker in Position 6 10 Breaker in Position 7 11 Breaker in Position 8 4 through 12 BREAKER RATING 00 No breaker 01 1 amp 03 3 amps 05 5 amps H7 7.5 amps W White Visi-Rocker indicate OFF M Medium Delay, Curve 14 13 APPROVALS A No approvals G UL/CUL 10 12 15 20 25 -A 12 Breaker in Position 9 13 Approvals 10 amps 12 amps 15 amps 20 amps 25 amps J UL/CUL, CE, TUV NOTES: Redundant feed. Breaker layout will be duplicated on the second feed. Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed. A panel plug will be supplied in the breaker positions that do not have a circuit breaker selected. LDM1-Series Dimensional Specifications 1.750 {44.45} 17.74[450.6] A 8.56[217.4] A 19.000 {482.6} 23.000 {584.2} with Optional Rack Extenders www.carlingtech.com 3 Carling Technologies LDM1-Series DC Secondary Power Distribution ™ Circuit Breakers Circuit breakers can be ordered separately to upgrade or reconfigure panel at a later date. Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory. General Specifications: UL/CUL and TUV approved 10000 STANDARD TRIP, MEDIUM DELAY, CURVE #14 MEDIUM DELAY CURVE NOS. 14, 24, 34, 64, 74 & 94 RATING (amps) BLACK ROCKER WHITE VISI-ROCKER 1 MA1-X-00-927-2-A26-2-J ME1-X-00-927-5-A16-2-J 3 MA1-X-00-902-7-A26-2-J ME1-X-00-927-6-A16-2-J 5 MA1-X-00-902-6-A26-2-J ME1-X-00-927-7-A16-2-J 7.5 MA1-X-00-927-3-A26-2-J ME1-X-00-927-8-A16-2-J 10 MA1-X-00-902-5-A26-2-J ME1-X-00-927-9-A16-2-J 12 MA1-X-00-927-47-A26-2-J ME1-X-00-928-0-A16-2-J 15 MA1-X-00-902-4-A26-2-J ME1-X-00-928-1-A16-2-J 20 MA1-X-00-902-3-A26-2-J ME1-X-00-928-2-A16-2-J 25 MA1-X-00-897-5-A26-2-J ME1-X-00-928-3-A16-2-J TRIP TIME IN SECONDS 1000 100 10 1 .1 .01 .001 100 300 200 400 500 600 700 800 900 1000 1100 1200 135 150 PERCENT OF RATED CURRENT M-SERIES TIME DELAY VALUES TRIP PERCENT OF RATED CURRENT TIME Delay 100% 135% 150% 200% 400% 600% 800% 1000% 1200% (SECONDS) 14,24,34,64,74,94 No Trip 3.00-70.0 2.00-40.0 1.00-15.0 .100-4.00 .008-2.00 .006-.800 .005-.350 .005-.160 Circuit Breakers Dimensional Specifications SINGLE POLE ±.030 ±.76 .360 [9.14] .305 [7.75] .770 [19.56] .680 [17.27] 1.530 [38.86] .675 [17.14] LOAD ON 1.560 [39.62] .970 [24.64] .915 [23.22] 1.375 [34.93] 1.050 [26.67] OFF LINE 20A .100 [2.54] .400 [10.16] ±.030 [±.76] 1.870 [47.46] TERMINAL DIMENSIONAL DETAIL PANEL CUT - OUT DETAILS: FRONT PANEL SNAP-IN MOUNTING 1.000 [25.4] PANEL THICKNESS .392 [9.97] CENTERLINE OF PUSH-IN STUD CONTACT AREA DIM. A .100 [2.54] .154 [3.91] DIA ±.005 ±.13 .062 [1.57] 1.385 [35.18] .093 [2.36] 1.420 [36.07] .125 [3.18] 1.460 [37.08] .71 [33.76] .750 [19.05] SOCKET MOUNT WITH FRONT PANEL ACCESS FOR ROCKER +.002 -.000 [+.050] [-.000] .700 [17.78] .161 DIA [Ø 4.10] PUSH-IN STUD MATING HOLE 4 1.070 [27.18] www.carlingtech.com DIM. A +.005 +.13 -.000 -.00 Carling Technologies LDC1-Series DC Secondary Power Distribution ™ To help conserve valuable panel space, Carling Technologies introduces a new 1RU DC Power Distribution Unit (PDU) for the telecom industry. This new PDU is designed to fit industry standard 19” rack systems. The 1RU is listed to UL/CUL 1801 and designed to EN60950. LDC1-Series: 19” or 23” One Rack Unit The LDC1-Series One Rack Unit (1RU) saves valuable real estate on a rack, while offering ease of installation and service. General Specifications Standards: Dimensions: Enclosure: Enclosure finish: Feeds: Load Connections: Operating Voltage: Alarm Feature: LED indicators: Chassis Ground: The Carling circuit breakers installed in the 1RU are plug in style to allow for hot swapability and front access, and are rated to 50 amps per pole with a standard 10,000 amp interrupting capacity rating and a special 50,000 amp interrupting capacity on request. Even as a “condensed” panel, this new 1RU exceeds the tough demands of today's applications while still offering safety, reliability and performance. Features & Benefits UL subject 1801 , CUL, TUV Approved CE approval pending Rack mounts to EIA standard EIA-310-D 19" rack for a 1RU panel, 1.75"H. 16 gauge galvaneel steel Powder coat, Gray Dual feeds, rated up to 150 amps per feed. Max. circuit breakers per feed: 6 Max. breaker rating: 50 amps. Connections: single hole ring terminal up to 2/0 awg For 150 amps continuous max. Requires 8 awg wire/ring or fork terminal for 50 A/75° C Rating, Top or bottom wire entry. -36V to –60V DC (-48VDC nominal) Power alarm: If either A or B FEED or both fail. Breaker alarm: If any populated breaker is OFF or “tripped.” Alarm is not affected by unused breaker positions. LED indicators on the front panel. Green lamps on A and B feeds. Red lamp for tripped breaker alarm indication. Via studs on the back panel and rack brackets to bare galvanized metal on the distribution unit. Use two hole x 5/8” center lugs. • • • • • • • • • • • Hot “swappable” circuit breakers that can be installed, changed, or replaced in the field or factory. Circuit breakers are front panel accessible. Breaker removal tools available upon request for installation and removal of circuit breakers. Maximum of six UL489 listed circuit breakers per feed. One Rack Unit (1RU) size. Panel plugs provided for non populated circuit breaker slots. Short handle circuit breakers to prevent accidental operation. Panel is easily configurable and upgradeable in the field. Provides flexibility when designing added features or options. Conserves valuable cabinet space to meet the tough demands of today’s applications. Consult factory or your local Carling Technologies representative for any custom panel requirements. Optional Rack Extenders to expand the panel mounting from a 19” rack to a 23” rack. Part Numbers: 8L1-A-DC1A (offset mounting) 8L1-A-DC1B (center mounting) www.carlingtech.com 5 Carling Technologies LDC1-Series DC Secondary Power Distribution ™ LDC1-Series Ordering Scheme - A L - 05 - 20 - 40 - 01 - 03 - 20 - A LDC1 2 Breaker Function 1 Series 5 Breaker in Position 2 4 Breaker in Position 1 3 Delay 1 SERIES LDC1 6 Breaker in Position 3 7 Breaker in Position 4 4 through 9 BREAKER RATING 00 No breaker 01 1 amp 03 3 amps 05 5 amps 10 10 amps 15 15 amps 2 BREAKER FUNCTION N No breaker A Standard Trip S Mid-Trip 3 DELAY N No breaker M Medium Delay, Curve 14 L Medium Delay, Curve 16 10 APPROVALS A No approvals G 10 Approvals 9 Breaker in Position 6 8 Breaker in Position 5 20 25 30 35 40 45 50 20 amps 25 amps 30 amps 35 amps 40 amps 45 amps 50 amps UL/CUL J UL/CUL, CE, TUV NOTES: Redundant feed. Breaker layout will be duplicated on the second feed. Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed. LDC1-Series Dimensional Specifications CHASSIS GROUND LOCATION: 2X 1/4-20 STUDS ON 5/8" (.625") CENTERS. BARE GALVANIZED METAL UNDER, TO ACCEPT TWO-HOLE WIRE LUG. 17.71[449.8} RETURNS ACCEPT SINGLE HOLE TERMINAL LUGS, FOR LOADS UP TO 2/0 AWG FOR MAIN, UP TO 6 AWG MAINS FEED BUS ACCEPTS SINGLE HOLE RING TERMINAL UP TO 2/0 AWG CABLE. BUS RATED 150 AMP CONTINUOUS, MIN. 12.00 [304.8} GREEN LED INDICTIONS FOR "POWER" ON A & B FEEDS RED LED ALARM INDICATION FOR EITHER "TRIPPED" OR "OFF" CONDITION ON ANY BREAKER; BREAKER POSITIONS NOT POPULATED DO NOT CAUSE ALARM CONDITION 1.750 {44.45} PANEL SUPPLIED CONFIGURED POPULATED WITH SPECIFIC BREAKER RATINGS / POSITIONS. UNPOPULATED POSITIONS SUPPLIED WITH PANEL PLUGS. BREAKER RATINGS IDENTICAL FOR A / B SIDES. 1.248 [31.7] .251[6.38] 19.000 {482.6} 6 www.carlingtech.com Carling Technologies LDC2-Series DC Secondary Power Distribution ™ To reduce space within Telecom cabinets without sacrificing power, Carling Technologies has introduced a versatile 1RU power distribution unit that combines GMT fuse protection with hydraulic-magnetic circuit breaker protection. This new LDC2Series panel is designed to fit industry standard 23” rack systems. The LDC2-Series panel features powerful dual feed redundancy for both the circuit breakers and the fuses. Hot “swappable” design allows the panel to be field or factory configured, and upgraded. LDC2-Series: 23” One Rack Unit The LDC2-Series One Rack Unit (1RU) combines GMT fuse and Hydraulic/magnetic Circuit Breaker Even in this compact package, this new LDC2-Series 1RU panel exceeds the tough demands of today’s applications, while offering safety, reliability and performance. protection in one compact package. General Specifications Standards: Dimensions: Enclosure: Feeds: Load Connections: Operating Voltage: Alarm Feature: LED indicators: Chassis Ground: Features & Benefits UL subject 1801, CUL and TUV Approved CE approval pending Rack mounts to EIA standard EIA-310-D 23” rack for a 1RU panel, 1.75” H. 16 gauge yellow zinc chromate cold rolled steel Dual feeds, rated up to 150 amps per feed. Max. circuit breakers per feed: 6 Max. breaker rating: 50 amps. GMT fuse feeds rated to 40A. Max. GMT fuses per feed: 4 Max. fuse rating: 10A Requires 1 awg wire/ring or fork terminal for 25 A/75 C Rating, Top or bottom wire entry. For 50A load with 25A terminal, fuse leads are through the connector. -36V to –60V DC (-48VDC nominal) Power alarm: If either A or B FEED or both fail. Breaker alarm: If any populated breaker is OFF or “tripped.” Alarm is not affected by unused breaker positions. LED indicators on the front panel. Green lamps on A and B feeds. Red lamp for tripped breaker alarm indication. Via studs on the back panel. Use two hole X 5/8” center lugs. Via Rack Mounting via brackets to yellow zinc chromate steel panel enclosure. • • • • • • • • • • • • LDC2-Series incorporates Carling AC-Series hydraulic/magnetic breakers, providing a superior level of performance. Versatile design combines circuit breaker and GMT fuse protection in one panel. Hot "swappable" circuit breakers that can be installed, changed, or replaced in the field or factory. Circuit breakers are front panel accessible. Breaker removal tools available upon request for installation and removal of circuit breakers. Maximum of six UL489 listed circuit breakers per feed, 12 per panel. One Rack Unit (1RU) size. Panel plugs provided for non populated circuit breaker slots. Short handle circuit breakers to prevent accidental operation. Panel is easily configurable and upgradeable in the field. Provides flexibility when designing added features or options. Conserves valuable cabinet space to meet the tough demands of today’s applications. Consult factory or your local Carling Technologies representative for any custom panel requirements. www.carlingtech.com 7 Carling Technologies LDC2-Series DC Secondary Power Distribution ™ LDC2-Series Ordering Scheme LDC2 1 Series - A L - 05 20 40 01 03 50 - A A A A - A 2 Breaker Function 4 Breaker in Position 1 3 Delay 5 Breaker in Position 2 6 Breaker in Position 3 1 SERIES LDC2 2 BREAKER FUNCTION N No breaker A Standard Trip S Mid-Trip 3 DELAY N No breaker M Medium Delay, Curve 14 L Medium Delay, Curve 16 12 Fuse in Position 3 10 Fuse in Position 1 11 Fuse in Position 2 4 through 9 BREAKER RATING 00 No breaker 01 1 amp 03 3 amps 05 5 amps 10 10 amps 15 15 amps 20 25 30 35 40 45 50 20 amps 25 amps 30 amps 35 amps 40 amps 45 amps 50 amps 10 through 13 FUSE RATING Z Dummy Fuse A .25 amp B .50 amp C .75 amp D 1 amp E 1.5 amps F G H I J K 2 amps 3 amps 4 amps 5 amps 7.5 amps 10 amps 7 8 Breaker in Breaker in Position 4 Position 5 9 Breaker in Position 6 14 APPROVALS A No approvals G UL/CUL 13 Fuse in Position 4 J UL/CUL, CE, TUV NOTES: Redundant feed. Breaker layout will be duplicated on the second feed. Feeds A and B are rated for 150 amps. Total combined breaker ratings can not exceed 150 amps per feed. GMT fuse feeds A & B are rated for 40 amps each. Total combined fuse ratings can not exceed 40 amps. LDC2-Series Dimensional Specifications MIDTRIP/STANDARD CIRCUIT BREAKER SELECTOR SWITCH 21.31 [541.2] 9.75 [247.7] 8.56 [217.4] 5.09 [129.3] .54 [13.8] .38 [9.5] 22.31[566.7] .44 [11] 1.75 [44.5] .87 [22.1] .28 [7.1] 1.37 [34.7] 8 www.carlingtech.com 14 Approvals Carling Technologies LDC1 & LDC2-Series Power Distribution Breakers ™ Circuit Breakers Circuit breakers can be ordered separately to upgrade or reconfigure panel at a later date. Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory. General Specifications: UL489, CSA and VDE approved 10,000 amp interrupting capacity C-SERIES TIME DELAY VALUES PERCENT OF RATED CURRENT TRIP Delay 100% 125% 150% 200% 400% 600% 800% 1000% 1200% TIME 14 No trip 2.00-60.0 1.20-40.0 .600-20.0 .150-3.00 .030-1.30 .004-.600 .004-.100 .004-.100 (SECONDS) 16 No Trip 45.0-345 20.0-150 9.00-60.0 1.40-11.4 .150-5.80 .009-3.70 .005-1.70 .005-.500 MEDIUM DELAY, CURVE #14 STANDARD TRIP 10000 MID-TRIP with LDC1-Series D.C. MEDIUM DELAY CURVE NO. 14 MID-TRIP with LDC2-Series 1 CA1-X0-09-031-AX1-MF CS1-X0-09-032-AX1-MF CT1-X0-09-032-AX1-MF 3 CA1-X0-08-981-AX1-MF CS1-X0-08-992-AX1-MF CT1-X0-08-992-AX1-MF 5 CA1-X0-08-982-AX1-MF CS1-X0-08-993-AX1-MF CT1-X0-08-993-AX1-MF 10 CA1-X0-08-983-AX1-MF CS1-X0-08-994-AX1-MF CT1-X0-08-994-AX1-MF 15 CA1-X0-08-984-AX1-MF CS1-X0-08-995-AX1-MF CT1-X0-08-995-AX1-MF 20 CA1-X0-08-985-AX1-MF CS1-X0-08-996-AX1-MF CT1-X0-08-996-AX1-MF 25 CA1-X0-08-986-AX1-MF CS1-X0-08-997-AX1-MF CT1-X0-08-997-AX1-MF 30 CA1-X0-08-987-AX1-MF CS1-X0-08-998-AX1-MF CT1-X0-08-998-AX1-MF 35 CA1-X0-08-988-AX1-MF CS1-X0-08-999-AX1-MF CT1-X0-08-999-AX1-MF 40 CA1-X0-08-989-AX1-MF CS1-X0-08-000-AX1-MF CT1-X0-08-000-AX1-MF 45 CA1-X0-08-990-AX1-MF CS1-X0-08-001-AX1-MF CT1-X0-08-001-AX1-MF 50 CA1-X0-08-991-AX1-MF CS1-X0-08-002-AX1-MF CT1-X0-08-002-AX1-MF 1000 100 TRIP TIME IN SECONDS RATING (amps) 10 1 .1 .01 .001 100 125 200 300 150 MID-TRIP with LDC1-Series 600 700 800 900 1000 1100 1200 D.C. LONG DELAY CURVE NO. 16 MID-TRIP with LDC2-Series 1 CA1-X0-08-561-AX1-MF CS1-X0-09-033-AX1-MF CT1-X0-09-033-AX1-MF 3 CA1-X0-07-803-AX1-MF CS1-X0-09-003-AX1-MF CT1-X0-09-003-AX1-MF 5 CA1-X0-07-804-AX1-MF CS1-X0-09-004-AX1-MF CT1-X0-09-004-AX1-MF 10 CA1-X0-07-805-AX1-MF CS1-X0-09-005-AX1-MF CT1-X0-09-005-AX1-MF 15 CA1-X0-07-806-AX1-MF CS1-X0-09-006-AX1-MF CT1-X0-09-006-AX1-MF 20 CA1-X0-07-807-AX1-MF CS1-X0-09-007-AX1-MF CT1-X0-09-007-AX1-MF 25 CA1-X0-07-645-AX1-MF CS1-X0-09-008-AX1-MF CT1-X0-09-008-AX1-MF 30 CA1-X0-07-646-AX1-MF CS1-X0-09-009-AX1-MF CT1-X0-09-009-AX1-MF 35 CA1-X0-07-808-AX1-MF CS1-X0-09-010-AX1-MF CT1-X0-09-010-AX1-MF 40 CA1-X0-07-809-AX1-MF CS1-X0-09-011-AX1-MF CT1-X0-09-011-AX1-MF 45 CA1-X0-07-810-AX1-MF CS1-X0-09-012-AX1-MF CT1-X0-09-012-AX1-MF 50 CA1-X0-07-811-AX1-MF CS1-X0-09-013-AX1-MF CT1-X0-09-013-AX1-MF 1000 100 TRIP TIME IN SECONDS STANDARD TRIP 500 10000 LONG DELAY, CURVE #16 RATING (amps) 400 PERCENT OF RATED CURRENT 10 1 .1 .01 .001 100 125 200 300 150 400 500 600 700 800 900 1000 1100 1200 PERCENT OF RATED CURRENT Circuit Breakers Dimensional Specifications .500 [12.67] ±.060 TYP-OPTIONAL "ON-0FF", I-O LEGEND SHORT HANDLE CIRCUIT BREAKER REQUIRES NO HANDLE GUARD, HAS MINIMAL HANDLE PROTRUSION IN "ON" AND "OFF" POSITION ±1.52 2.810 [71.38] TYP .406 [10.31] 1.850 [47.00] TYP LINE ON I .960[24.38] .640 [16.26] .930 [23.62] C 1.220 [30.98] 2.500 [63.50] TYP NO 60° 1.438 [36.53] OFF O .558[14.17] CENTERLINE OF PUSH-IN STUD CONTACT AREA NC 30° ±.020 ±.51 1.940 [49.28] TYP F OF O .755 [19.18] MAX. .135 [3.42] .150 [3.81] TYP. LOAD ±.020 ±.51 .273 [7.14] TYP PUSH-IN STUD DETAIL 2.250 [57.15] TYP #6-32 [M3] THREAD X .195 [4.95] DEEP (2 PLCS) / POLE www.carlingtech.com 9 Carling Technologies LAC1-Series Telecom AC Power Distribution Panel ™ LAC1-Series: Telecom AC PDC The LAC1-Series AC PDC provides custom configurations in a standard format. The LAC1-Series eliminates the need to invest in custom designed AC power requirements. The LAC1-Series is a standard AC load center designed for today’s Telecommunications requirements, and is available from 120-240VAC. General Specifications Standards: Dimensions: Enclosure: Mains Breaker: Loads: Service Outlet: Operating Voltage: Service Entry: Load Center Breakers: 10 Features & Benefits UL67 Listed for AC Panelboards Wall mount enclosure. 20”W x 14”H x 3.84”D 16 gauge cold rolled steel with a powder coat finish. 2-pole 100 amp mains breaker, 120/240 vac, 50-60 Hz, & 2-pole 100 amp generator back-up breaker, tied together, but with independent operation. Slide-bar, lock-out feature allows transfer from AC to generator power. Slots for up to 13 poles of branch circuit breakers. Circuit breakers 1-4: reserved for 2-pole breakers. Circuit breakers 5-6: reserved for one, 2-pole breaker or two single pole breakers. Circuit breaker 7: reserved for a 2-pole 15A circuit breaker (preloaded) for the GFI service outlet & optional surge suppressor. Circuit breaker 8: reserved for a single pole circuit breaker 15 Amp, 120VAC GFI 120/240VAC, or 120/208V @ 50/60 Hz, 70 Amps single phase. Service Entry fittings located at the bottom, and bottom right corner of the enclosure. UL489 C-Series w/ clip terminals & maximum rating of 50 amps per position with a total per panel of 70 amps or less. • • • • • • • • • • • • • Versatile design allows custom configurations of branch circuits based on individual applications. Circuit breakers snap-in to Carling Technologies’ exclusive circuit breaker mounting block. No need to hard wire the circuit breakers. Easy change over from main to generator power by use of a slide bar. UL listed to UL67 for AC panel boards. GFI convenience outlet is included for service. AC panel was designed for easy wiring. Ordering scheme assists you in ordering a custom solution from a standard product. Individual circuit breaker part numbers are provided which allow you to easily upgrade your existing panel in the future. Front cover is easily removed. Handleguards protect breakers. Breaker handles are visible through the front cover of the panel to allow easy breaker status identification . Breaker state can be changed without opening panel. Branch Circuits protected by Carling C-Series UL489 hydraulic/magnetic listed, VDE approved breakers, with clip terminals that allow easy snap-in mounting of breakers into the AC panel. Breaker trip and Current ratings are unaffected by ambient temperatures. www.carlingtech.com Carling Technologies LAC1-Series AC Power Distribution ™ LAC1-Series Ordering Scheme LAC1 - 05 05 05 20 - 1 10 1 10 - 15 - 15 1 Series 2 Breaker in Position 1 3 Breaker in Position 2 4 Breaker in Position 3 5 Breaker in Position 4 1 SERIES LAC1 2 through 5 TWO POLE BREAKER RATING 00 No breaker 20 20 amps 05 5 amps 25 25 amps 10 10 amps 30 30 amps 15 15 amps 35 35 amps 40 45 50 40 amps 45 amps 50 amps 7 6 8 # Poles in Breaker in # Poles in Position 5 Position 5 Position 6 9 Breaker in Position 6 7 and 9 BREAKER RATING 00 No breaker 20 05 5 amps 25 10 10 amps 30 15 15 amps 35 10 Breaker in Position 7 20 amps 25 amps 30 amps 35 amps 40 45 50 40 amps 45 amps 50 amps 40 45 50 40 amps 45 amps 50 amps 10 TWO POLE BREAKER RATING 15 15 amps 11 SINGLE POLE BREAKER RATING 00 No breaker 20 20 amps 05 5 amps 25 25 amps 10 10 amps 30 30 amps 15 15 amps 35 35 amps 6 and 8 NUMBER OF POLES1 0 No breaker 1 single pole 2 two pole 11 Breaker in Position 8 NOTES: 1 If choosing single pole breakers, you must choose breakers for both positions 5 and 6. If choosing a two pole breaker in position 5, then position 6 (selected in fields 8 and 9) must be “no breaker”. LAC1-Series Dimensional Specifications www.carlingtech.com 11 Carling Technologies LAC1-Series AC Power Distribution ™ Circuit Breakers Circuit breakers can be ordered separately to upgrade or reconfigure panel at a later date. Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory. General Specifications: UL489, CSA and VDE approved 10,000 amp interrupting capacity C-SERIES TIME DELAY VALUES TRIP PERCENT OF RATED CURRENT TIME Delay 100% 125% 135% 150% 200% 400% 600% 800% 1200% (SECONDS) 24 No trip 10.0-160 - .600-60.0 2.20-20.0 .300-3.00 .050-1.30 .007-.500 .005-.040 MEDIUM DELAY, CURVE #24 10000 SINGLE POLE TWO POLE 5 CA1-X0-09-250-C2X-KG CA2-X0-09-244-C2X-CG 10 CA1-X0-06-604-C2X-KG CA2-X0-07-169-C2X-CG 15 CA1-X0-09-251-C2X-KG CA2-X0-08-169-C2X-CG 20 CA1-X0-06-606-C2X-DJ CA2-X0-04-891-C2X-CG 25 CA1-X0-09-252-C2X-KG CA2-X0-09-245-C2X-CG 30 CA1-X0-09-253-C2X-KG CA2-X0-06-299-C2X-CG 35 CA1-X0-09-254-C2X-KG CA2-X0-09-246-C2X-CG 40 CA1-X0-09-255-C2X-KG CA2-X0-09-247-C2X-CG 45 CA1-X0-09-256-C2X-KG CA2-X0-09-248-C2X-CG 50 CA1-X0-09-261-C2X-KG CA2-X0-09-249-C2X-CG 50/60 Hz MEDIUM DELAY CURVE NO. 24 1000 TRIP TIME IN SECONDS RATING (amps) 100 10 1 .1 .01 .001 100 200 300 400 500 600 700 800 125 150 Circuit Breakers Dimensional Specifications 12 www.carlingtech.com PERCENT OF RATED CURRENT 900 1000 1100 1200 Carling Technologies LBD-Series Battery Disconnect Panel ™ The LBD-Series battery disconnect panels were designed with performance, style and size in mind. Carling Technologies has packed this product line with ratings up to 700A, interrupt capacity of 50,000A, PDC voltage ratings of -36 to -60 VDC and in sizes starting as small as 1 rack unit (1RU) x 19”, up to 3RU. LBD-Series: Battery Disconnect Panels The LBD-Series addresses the demanding requirements associated with today’s Telecommunication Networks. The LBD-Series Battery Disconnect Panels provide battery protection in rack mount and enclosure style while freeing up valuable real estate within your cabinet. General Specifications Standards: Dimensions: Enclosure: Current Ratings: Circuit Breaker Voltage Ratings: Interrupting Capacity: Alarm Feature: Ambient Temperature: LED indicators: Rack Mount Insulators: Meter Shunt Option: Chassis Ground: Lug Connections: Lugs Required: Features & Benefits UL Listed Rack mounts to EIA standard EIA-310-D, 1-3RU, 19” or 23” panel 14 gauge Galvaneel steel w/ powder coat finish, & Bare metal ground. 250 amps/ 1RU;400 amps/2RU 700 amps/3RU 125 vdc 50,000 amps @ 60 vdc Std. 1 form C contact for power ON/OFF, 1 form C, Contact for breaker OFF/TRIPPED. -40°C to +60°C Green lamp for power indication. Red lamp for alarm indication. UL94V-0 material over all live parts. Optional meter shunt provides 25m V at rated current. Bare metal to rack mount flange & 1/4 - 20 stud to bare metal. Busbars accept 2-hole std. telecom lugs up to 750 mcm cable. 1 lug-up to 250 amps; 2 lugs-up to 400 amps; 3 lugs- up to 700 amps. Lugs can be mounted on either or both sides. Lugs can be through bolted on each side of the bus bar, doubling lug capacity. 1.75” hole spacing, 1/2: bolt lug, max. 1.75” wide • • • • • • • • • • Panel incorporates Carling F-Series high amperage hydraulic/magnetic breakers: providing a superior level of performance. Each panel is sized for maximum protection in the smallest size possible to conserve valuable cabinet space. Starting with a compact 1RU x 19” rack rated up to 250 amps @ 60 vdc with a 50,000 AIC. Front panel access. Insulator covers are standard to protect live parts once the panel is installed. Front panel is provided with a circuit breaker handle guard to protect from unintentional operation. LED indications are standard for visual monitoring. The LBD provides, as a standard, a circuit breaker alarm feature to alert breaker trip or off conditions. Voltage, or current monitoring, and remote shut down options are offered. Cable connections on thick silver plated, copper busbars, which accept standard 2-hole telecom lugs from 1 AWG to 750 MCM sizes. Lugs can be mounted on either or both sides of the bus bars. www.carlingtech.com 13 Carling Technologies LBD-Series Battery Disconnect Panels ™ LBD-Series Ordering Scheme LBD P 1 1 Series 2 Style - 1 - 810 - A - A - 0 - 0 - A 3 Rack Size 4 Function 5 Current Rating 1 SERIES LBD E 2 4 FUNCTION Switch Only 0 1 Series Trip 5 CURRENT RATING 810 100 amp (1RU) 820 200 amp (1RU) 7 Metering Shunt 6 BUS BAR TYPE figure 1 A 2 STYLE Rack Mount P 3 RACK SIZE 19” rack 1 6 Bus Bar Type 23” rack E 2 3 825 840 Enclosure/Wall Mount 250 amp (1RU) 400 amp (1RU) Enclosure Series Trip with Aux. Switch Mid-trip with Alarm Switch 860 870 600 amp (1RU) 700 amp (1RU) 10 Approvals 9 Special Options B figure 1 w/ PEM studs 7 METERING SHUNT 0 No shunt A Metering shunt 8 REMOTE DISCONNECT VOLTAGE 0 No remote option A 24 vdc B 48 vdc C 120 vdc D 240 vdc 9 SPECIAL OPTIONS 0 None X Consult factory 10 APPROVALS A No approvals B UL Listed NOTES: Circuit breakers are provided with a DC medium delay curve. 1 Current & voltage monitoring are available as special options. Select X in position 9, and advise factory. LBD-Series Rack Mount Dimensional Specifications 14 8 Remote Disconnect Voltage www.carlingtech.com Carling Technologies LBD-Series Battery Disconnect Panels ™ LBD-Series Wall Mount Dimensional Specifications Circuit Breakers Circuit breakers can be ordered separately to upgrade or reconfigure panel at a later date. Standard circuit breaker part numbers are listed on the chart below. For other ratings, consult factory. F-SERIES TIME DELAY VALUES TRIP PERCENT OF RATED CURRENT TIME Delay 100% 125% 150% 200% 400% 600% 800% 1200% (SECONDS) 14 No trip 10.0-110 .600-40.0 2.50-15.0 .500-3.00 .180-1.00 .010-.280 .008-.080 10000 D.C. MEDIUM DELAY CURVE NO. 14 General Specifications: UL489, CSA and VDE approved 10,000 amp interrupting capacity 1000 TRIP TIME IN SECONDS 100 10 1 .1 .01 .001 100 125 200 300 400 500 600 700 800 900 1000 1100 1200 150 PERCENT OF RATED CURRENT www.carlingtech.com 15 Carling Technologies Power Distribution Accessories ™ Panel Hole Plug 809-70194-001 1 Part Number 1 PART NUMBER 809-70194-001 809-70194-002 LAC1 Snap-In Panel Plugs LDC1 & LDC2 Snap-In Panel Plugs C-Series with Push-In Stud Terminals Mounting Kit & Removal Tool Circuit Breaker Removal Tool 8C1-X0-08-639 1 Part Number 1 PART NUMBER 8C1-X0-08-639 8C1-X0-09-593 8C1-X0-07-628 Removal Tool for 6-32 inserts Removal Tool for M3 inserts Mounting kit for one circuit breaker position (includes mounting block, bullet sockets, aux. switch, PC board connectors, aux. switch connector housing and two screws. Bus bar and PCB are not included in the mounting kit.) C-Series Circuit Breaker Module for DC Power Distribution L0053 1 Part Number 1 PART NUMBER L0053 8C1-X0-08-573 Circuit Breaker Module • Six position circuit breaker module, individual circuit breaker slot rated to 100amps • Hot swappable plug-in circuit breakers • UL489 listed hydraulic/magnetic circuit breakers available for the module • Breaker alarm circuit • 300 amp line bus • Custom mounting block allows for Load bus to easily change • Building block design allows for easy changes Circuit Breaker Module Kit for individual loads (includes mounting block, auxiliary switch housing, rivet, two screws, two push-in terminal receptacles and three .110QC terminal receptacles.) C-Series Circuit Breaker AC Plug-In Bracket PR8080-667 1 Part Number 1 PART NUMBER PR8080-667 16 C-Series Circuit Breaker AC Plug-In Bracket www.carlingtech.com Carling Technologies Custom Power Distribution Solutions ™ Custom Power Distribution Solutions Carling Technologies offers expertise in electrical and mechanical design, tooling, prototyping, testing, and manufacturing. At Carling we do much more than manufacture standard products. Our dedicated PDC team provides innovative design and skillfully engineered power distribution solutions to meet today's demanding custom requirements. We work closely with your engineering team to meet your application requirements and exceed your expectations. Let the Carling PDC team design and develop a custom Power Distribution Center or Battery Disconnect Panel that will meet your special requirements. Please take a moment to browse through our PDC photo galleries and view some examples of our custom design & solution capabilities. Then contact us today and let us assist you with your custom designs. Custom Battery Disconnect Gallery L0054 • Battery disconnect for single battery string • Mounts directly to a battery housing • Connections made by Anderson Connectors • UL489 Listed hydraulic/magnetic circuit breaker • Circuit breaker rating 100A @ 80VDC with a 50,000 AIC L0059 • Battery Disconnect for multiple battery strings • Two UL489 Listed hydraulic/ magnetic circuit breakers, one to disconnect an individual battery string, one to disconnect the entire battery system • Breakers are rated for 100 amps @ 80VDC with 50,000 AIC • Panel attaches directly to a battery compartment • Connections made with Anderson Connectors Custom AC Gallery L0005 • 100 amp rating • 208-420VAC • UL489 listed hydraulic magnetic circuit breakers • Optional surge suppressor 4-115V convenience outlets, GFI & non-GFI protected 4-250V twist lock • Designed for UL50 L0066 • 23" rack mount design • 100 amp 3 pole UL489 listed Mains circuit breaker • 16 slots for plug-in circuit breakers • Rocker style branch circuit breaker with rocker guard and visual trip indication • Hydraulic magnetic circuit breakers • Power strip top for a variety of outlets L0069 Remote Power Management • Independent circuit breakers controlled remotely via your phone • RPMS calls an assigned phone number when a breaker has tripped, & allows you to service or reset the breaker over the phone • Dial up feature allows you to change breaker states as needed L0081 • UL67 listed for AC panelboards • Wall mount enclosure • 70A 2 pole Mains breaker, with 2 pole 70A generator back-up breaker tied together but operating independently • Slide bar lock out allows transfer slots for up to 13 poles of branch circuit breakers • UL489 listed hydraulic/magnetic breakers with handle guards • 15 amp GFI service outlet • Circuit breakers visible through front cover L0118 • Compact wall mount design • 2 pole circuit breaker for rectifiers • 1 pole circuit breaker for battery heater • 1 pole circuit breaker for GFI outlet • GFI service outlet • Battery heater outlet • UL489 listed hydraulic/magnetic breakers with handle guards • Designed for UL67 L0125 • Compact wall design • 30A 3 pole Mains breaker with 3 pole generator back-up breaker tied together but operating independently - slide bar lock out allows transfer • Slots for up to 10 poles of branch circuit breakers • UL489 listed hydraulic magnetic circuit breakers www.carlingtech.com 17 Carling Technologies Custom Power Distribution Solutions ™ Custom DC Gallery L0039 - Alarm Panel • 23" rack mount alarm panel, with front handles for easy mounting, thumb screws for easy access • Ability to monitor up to 144 circuit breaker positions, DC volt monitoring display, DC amp monitoring display • Audible alarm mute feature • Front access fuse protection, voltage & amp monitoring front access plugs • 2 surge suppressors,15 amp GFI Service outlet • Entry for large generator connector L0039 - High Power PDC • 23" rack mount design • 48 circuit breaker position panel • Hot swappable UL489 Listed hydraulic/magnetic breakers • Mid-trip alarm indication • Ratings up to 100 amps per slot • 800 amp bus L0056 • 23" rack mount panel with hinged front cover, designed for UL1801 • 16 poles available for hot swappable plugin circuit breakers • UL489 Listed mid-trip hydraulic magnetic circuit breakers with handle guards • 20 position GMT fuse panel • 800 amp LOW VOLTAGE DISCONNECT • Front access alarm and load connections • Visual alarm and power indicators L0074 • 23" rack mount DC distribution panel • 3 rack units tall • Redundant feeds • 5 circuit breakers per feed • Front access alarm connection • Hot swappable UL489 Listed hydraulic/magnetic breakers • Powder coat finish • Open back for easy access L0078 • 19" rack mount DC panel • Dual feed • Four circuit breakers per feed • 200 amp rating per feed • Alarm monitoring: Major, Minor, Critical • Power indicator • UL489 Listed hydraulic/magnetic rocker style breakers with visual trip indication and rocker guards • Designed for UL1801 and NEBs L0082 • 1 rack unit tall (1.75") for a 23" rack • Dual feed • 6 hot swappable plug-in circuit breakers, 300A rating per feed • Dual feed GMT fuse panel, 4 fuses per feed • UL489 Listed hydraulic/magnetic mid-trip circuit breakers with short handle design to hinder unintentional operation • Extended top cover over the front of panel for added protection • Rear insulator • UL1801 and CSA approved L0105 • 1 rack unit tall (1.75") for a 19" rack • Dual feed • Each feed consists of 2 hot swappable plug-in breakers and 10 GMT fuses • 50A max rating per breaker • 10 amp max rating per GMT fuse • Removable alarm card • Visual alarm indications: Major, Minor, Critical Power indicator • UL489 Listed hydraulic magnetic rocker style circuit breakers with rocker guard & visual trip indicator Warranty Policy Carling Technologies, Inc. (Seller) warrants that goods sold hereunder shall be free of defects in material and workmanship for one year from date of shipment. In the event of such defects, the Seller’s only obligation shall be the replacement or the cost of the defective goods, themselves, excluding, without limitation, labor costs, which are or may be required in connection with the replacement or reinstallation of the goods. This warranty is the Seller’s sole obligation and excludes all other remedies or warranties, express or implied, including warranties of merchantability and fitness for a particular purpose, whether or not purposes or specifications are described herein. This Warranty expressly excludes any and all incidental, special and/or consequential damages of any nature. Seller further disclaims any responsibility for injury to person or damage to or loss of property or value caused by any product which has been subjected to misuse, negligence, or accident; or misapplied, or modified or repaired by a person or persons not authorized by the Seller or which have been improperly installed. 18 www.carlingtech.com Carling Technologies Power Distribution Project Design Form ™ Carling Technologies Power Distribution Project Design Form ™ Innovative Designs. Powerful Solutions. *** Please fax completed forms to 860-793-9231 or email to: [email protected] *** PROJECT INFORMATION: Index Number: Submittal Date: Sales Representative: Phone/email: Rep. Company: Region Manager: CUSTOMER INFORMATION: Company Name: Date of Non-Disclosure: Address: City, State, ZIP: Engineering Contact: Title: Phone: Fax: email: Purchasing Contact: Title: Phone: Fax: email: APPLICATION INFORMATION: Acceptable electronic files: IGS DXF Application: DWG PDF STEP other: EAU Year 1: EAU Year 2: EAU Year 3: # of prototypes: Pilot Production Schedule: Schematic Available?: Product Life: Project Value: Redesign Details: Specifications Available?: New Product Details: Development Budget Limitations: Existing Sample Available?: Target Price: Target Price: SPECIFICATIONS: Open/Closed Frame: AC/DC Voltage: For DC, Rack Type: Operating Voltage Tolerance: Enclosure Dimensions: 19": 23": Mains Feed Amps: Number of Breakers: If necessary, add additional information to notes section below, or attach second sheet. Type of Trip Indication Alarming Required: AGENCY APPROVALS: UL UL STD CUL TUV CE Other: COMPETITIVE INFORMATION: Competition: Competitors Part Number: Current Price: NOTES AND ACTION ITEMS: www.carlingtech.com 19 Carling Technologies 20 Notes ™ www.carlingtech.com Other Carling Technologies Catalogs Thermal Circuit Protectors Circuit Protection This catalog details This catalog details Carling’s thermal cir- the complete line of cuit protection prod- Carling circuit protec- ucts. Thermal pro- tion products includ- tectors range from ing hydraulic/mag- 0.1 to 40 amps. netic circuit breakers Front Panel Snap-in and ground fault Mounting styles and breakers. Breakers Quick Connect range from 0.1 to Terminals are includ- 700 amps Hi-inrush ed. Worldwide certifications, including UL1500, delay curves, Front Panel Snap-in Mounting styles, TUV and CE marked. Rockerguard Bezels, Dual-Coil functions, and Quick Connect Terminals are included. Worldwide certifications, including UL1500, UL489 and CE marked. Digital Switching Systems Switches and Electronic Controls This catalog includes This catalog details the complete line of Carling’s Digital Electronic Controls Switching System: and Carlingswitch the ECS III. The ECS brand electrical III (Electronic Control switches for most System), features any power switching the latest in digital need. Included are multiplex technology, dimmer, wiper, and creating a safer and mirror rotate controls, along with rocker, toggle, pushbutton, rotary and sealed switches with a wide variety of circuits, ratings, terminations, colors, illuminations, and legends. Worldwide certifications, UL1500, CE marked. fully configurable control system for the marine environment. The ECS III eliminates complex wiring while increasing switching features and functionality, and simplifying troubleshooting. www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc., Connecticut, USA (860) 793-9281, fax: (860) 793-9231 e-mail: [email protected] www.carlingtech.com Eastern U.S. and Eastern Canada: (860) 586-8413, fax: (860) 586-8513 e-mail: [email protected] Midwestern U.S.: (815) 653-9333, fax: (815) 653-2206 e-mail: [email protected] Western U.S., Western Canada, Mexico and South America: (972) 509-0807, fax: (972) 509-0368 e-mail: [email protected] Europe/Middle East/Africa Headquarters Carling Technologies Ltd., Devon, England Int + 44 1392-364422, fax: Int + 44 1392-364477 e-mail: [email protected] Central Europe: Carling Technologies GmbH Int + 49 6104-959157, fax: Int + 49 6104-959158 e-mail: [email protected] Southern Europe: Carling Technologies SARL Int + 33 3 84 43 0706, fax: Int + 33 3 84 43 14 44 e-mail: [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Int + 852-2737-2277, fax: Int + 852-2736-9332 e-mail: [email protected] China Int + 86-21-6390-6916, fax: Int + 86-21-6390-6918 e-mail: [email protected] Japan Int + 813-5789-2925, fax: Int + 813-5789-2927 e-mail: [email protected] PD_7_03