Film - Snubber Capacitors for IGBT Modules

Film
PRODUCTS
Snubber Capacitors for IGBT Modules
Why Choose KEMET
Programs Supported
KEMET applies world-class service and quality
to deliver industry-leading, high performance
capacitance solutions worldwide. With 95% of
possible dielectric solutions, KEMET offers the
world’s most complete line of surface mount
and through-hole capacitor technologies across
tantalum, ceramic, film, aluminum and paper
dielectrics. One world. One KEMET.
Power semiconductor snubbing, including IGBT direct mount
Steps for Choosing an IGBT Snubber Capacitor to Test
1. Choose the snubber voltage to match (or exceed) the IGBT voltage.
2. Choose an initial capacitance value using the diagram below.
3. Choose a tab style code from the diagrams on the reverse side.
4. Choose the desired part number from the datasheet.
The tab style code is digit 13. Example: C4BSNBX4200ZALJ is tab style A.
IGBT with screw connections
Product Checklist
• Does the IGBT module have screw
or pin connections?
• What is the actual IGBT current?
• Will the snubber capacitor be used by
itself or in a network with other components?
• What is the rated voltage of the IGBT?
Snubber in network
• Wide capacitance & voltage range
• Direct mount version with six tab styles
to fit most IGBTs
• 4-pin PCB mount version available
• Stable temperature characteristics
• Pb-free/RoHS-compliant
• Made with low-loss polypropylene film
Snubber by itself
Features & Benefits
Series C4BS
direct mount
Series C4AS
PC board mount
Cap value =
0.5 µF per 100 A
IGBT current
(1.0 µF per 100 A
if high inductance
expected)
Cap value =
0.25 µF per 100 A
IGBT current
IGBT with pin connections
Series C4AS
PC board mount
Series C4AS
PC board mount
Cap value =
0.5 µF per 100 A
IGBT current
(1.0 µF per 100 A
if high inductance
expected)
Cap value =
0.25 µF per 100 A
IGBT current
This is a starting point. The engineer will pick the final cap value after evaluation and testing.
Snubber capacitor
by itself
Snubber capacitor
in a network
KEMET Products
Capacitor Type
Rated Voltage
Cap Range
Characteristics
C4AS
Radial Leads
850 VDC/500 VAC
0.15 – 5.0 µF
• Snubber applications
1000 VDC/600 VAC
0.15 – 4.7 µF
• Climatic category (IEC 60068-1) 40/85/56
1200 VDC/630 VAC
0.1 – 3.5 µF
• Pulse rise time (dv/dt) 469 to 3360 V/µs
2000 VDC/700 VAC
0.033 – 1.5 µF
• Pitch (p) p = 27.5, 37.5, 52.5 mm
3000 VDC/750 VAC
0.022 – 0.82 µF
• Terminals tinned copper 2 or 4 wires
850 VDC/550 VAC
0.47 – 5.0 µF
• Snubber-IGBT applications
1000 VDC/600 VAC
0.47 – 4.0 µF
• Climatic category (IEC 60068-1) 40/85/56
1200 VDC/630 VAC
0.33 – 3.3 µF
• Pulse rise time (dv/dt) 469 to 3361 V/µs
2000 VDC/700 VAC
0.10 – 1.5 µF
• Box Length (L) L = 32 to 57.5 mm
3000 VDC/750 VAC
0.047 – 0.82 µF
• Terminals tinned brass lugs
C4BS
Direct Mount
For more information, samples
and engineering kits,
please visit us at www.kemet.com
or call 1.877.myKEMET.
SA0912
Copyright © 2012 KEMET
Film
PRODUCTS
Snubber Capacitors for IGBT Modules
Application of C4B Tab Styles
The tab style code is digit 13 in the part number. Example: C4BSNBX4200ZALJ is tab style A
General description of tab styles. Also see detailed diagrams below.
Sugg. tabs for common IGBTs (always check specific cases).
Tab Styles
Cap Length
Pitch Range
Notes
IGBT Mfr
Series
A
41.5 - 42.5 mm
21.5 - 29.5 mm
Fits most common IGBTs
Semikron
SKM
B
41.5 - 42.5 mm
16.0 - 28.0 mm
Fits most common IGBTs
Semikron
Skiip®
H
41.5 - 42.5 mm
21.5 - 29.5 mm
Alternative to “A” with lower mounting height
Powerex/Mitsubishi
CM up to 300
A, B, H
57.5 mm
Larger pitches for high power IGBTs, see diagram below
Powerex/Mitsubishi
CM 400 & up
E
B = 18 mm
For the Semikron Skiip® module, 31 mm terminals
Infineon/Eupec
BSM
F
Specialty type on demand, see diagram below
Microsemi
APT
G
Specialty type on demand, see diagram below
Above applies to cap length 41.5 - 42.5 mm or B=18 mm for tab style E.
SA0912
31 mm
A
B
E
H
Copyright © 2012 KEMET