IDT IDT74CBTLV16212PAG

IDT74CBTLV16212
LOW-VOLTAGE 24-BIT BUS EXCHANGE SWITCH
INDUSTRIAL TEMPERATURE RANGE
LOW-VOLTAGE 24-BIT
BUS EXCHANGE SWITCH
IDT74CBTLV16212
DESCRIPTION:
FEATURES:
5Ω
Ω A/B bi-directional switch
Isolation Under Power-Off Conditions
Over-voltage tolerant
Latch-up performance exceeds 100mA
VCC = 2.3V - 3.6V, normal range
ESD >2000V per MIL-STD-883, Method 3015; >200V using
machine model (C = 200pF, R = 0)
• Available in SSOP, TSSOP, and TVSOP packages
The CBTLV16212 provides a set of 24 high-speed switches for bus
exchanging and switching. The device has low ON resistance, resulting
in under 250ps propagation delay through the switch. The CBTLV16212
operates as a single 24-bit bus switch or as a 12-bit bus exchanger, which
provides data exchanging between the four signal ports through the data
select (S0-S2) pins.
The CBTLV16212 has the break-before-make feature, which allows
zero current when switching between ports B1 and B2.
•
•
•
•
•
•
APPLICATIONS:
• 3.3V High Speed Bus Switching and Bus Isolation
FUNCTIONAL BLOCK DIAGRAM
1A 1
2
SIMPLIFIED SCHEMATIC, EACH
SWITCH
54
SW
1B 1
SW
SW
1A 2
3
53
SW
1B 2
A
12 A 1
27
30
SW
B
12 B 1
SW
SW
12 A 2
28
29
SW
12 B 2
FLOW CONTROL
CIRCUITRY
S0
S1
S2
1
56
55
The IDT logo is a registered trademark of Integrated Device Technology, Inc.
INDUSTRIAL TEMPERATURE RANGE
AUGUST 2002
1
c
2002 Integrated Device Technology, Inc.
DSC-5889/5
IDT74CBTLV16212
LOW-VOLTAGE 24-BIT BUS EXCHANGE SWITCH
INDUSTRIAL TEMPERATURE RANGE
PIN CONFIGURATION
ABSOLUTE MAXIMUM RATINGS(1)
Symbol
Description
Max.
Unit
Supply Voltage Range
–0.5 to 4.6
V
Input Voltage Range
56
S1
VCC
2
55
S2
VI
1A2
3
54
1B1
2A1
4
53
1B2
2A2
5
52
2B1
3A1
6
51
2B2
3A2
7
50
3B1
GND
8
49
GND
4A1
9
48
3B2
4A2
10
47
4B1
5A1
11
46
4B2
5A2
12
45
5B1
6A1
13
44
5B2
6A2
14
43
6B1
Sx
Data Select
Port A Inputs or Outputs
Port B Inputs or Outputs
S0
1
1A1
IIK
–0.5 to 4.6
V
Continuous Channel Current
128
mA
Input Clamp Current, VI/O < 0
–50
mA
–65 to +150
°C
Storage Temperature Range
TSTG
NOTE:
1. Stresses greater than those listed under ABSOLUTE MAXIMUM RATINGS may cause
permanent damage to the device. This is a stress rating only and functional operation
of the device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect reliability.
PIN DESCRIPTION
Pin Names
Description
7A1
15
42
6B2
xAx
7A2
16
41
7B1
xBx
VCC
17
40
7B2
8A1
18
39
8B1
GND
19
38
GND
8A2
20
37
8B2
S2
Inputs
S1
9A1
21
36
9B1
L
L
9A2
22
35
9B2
L
L
10A1
23
34
10B1
L
H
L
B2
Z
A1 port = B2 port
10A2
24
33
10B2
L
H
H
Z
B1
A2 port = B1 port
11A1
25
32
11B1
H
L
L
Z
B2
A2 port = B2 port
11A2
26
31
11B2
H
L
H
Z
Z
Disconnect
12A1
27
30
12B1
H
H
L
B1
B2
A1 port = B1 port
12A2
28
29
12B2
FUNCTION TABLE(1)
Inputs/Outputs
A1
A2
Operation
L
Z
Z
Disconnect
H
B1
Z
A1 port = B1 port
S0
A2 port = B2 port
H
SSOP/ TSSOP/ TVSOP
TOP VIEW
H
H
B2
B1
A1 port = B2 port
A2 port = B1 port
NOTE:
1. H = HIGH Voltage Level
L = LOW Voltage Level
Z = High-Impedance
OPERATING CHARACTERISTICS(1)
Symbol
Parameter
VCC
Supply Voltage
VIH
High-Level Control Input Voltage
VIL
Low-Level Control Input Voltage
TA
Operating Free-Air Temperature
Test Conditions
Min.
Max.
Unit
2.3
3.6
V
VCC = 2.3V to 2.7V
1.7
—
V
VCC = 2.7V to 3.6V
2
—
VCC = 2.3V to 2.7V
—
0.7
VCC = 2.7V to 3.6V
NOTE:
1. All unused control inputs of the device must be held at VCC or GND to ensure proper device operation.
2
—
0.8
–40
+85
V
°C
IDT74CBTLV16212
LOW-VOLTAGE 24-BIT BUS EXCHANGE SWITCH
INDUSTRIAL TEMPERATURE RANGE
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Condition: TA = –40°C to +85°C
Symbol
Typ.(1)
Max.
—
—
–1.2
V
—
—
±1
µA
—
—
5
µA
VCC = 0V, VI or VO = 0V or 3.6V
—
—
10
µA
VCC = 3.6V, IO = 0, VI = VCC or GND
—
—
10
µA
Parameter
Test Conditions
Control Inputs, Data I/O
VCC = 3V, II = –18mA
Control Inputs
VCC = 3.6V, VI = VCC or GND
Data I/O
VCC = 3.6V, VO = 0V or 3.6V switch disabled
IOFF
ICC
VIK
II
I OZ
Min.
Unit
∆ICC(2)
Control Inputs
VCC = 3.6V, one input at 3V, other inputs at VCC or GND
—
—
300
µA
CI
Control Inputs
VI = 3V or 0
—
5
—
pF
VO = 3V or 0 (switch off)
—
13.5
—
pF
IO = 64mA
—
5
8
IO = 24mA
—
5
8
VI = 1.7V
IO = 15mA
—
27
40
VI = 0
IO = 64mA
—
5
7
IO = 24mA
—
5
7
IO = 15mA
—
10
15
CIO(OFF)
Max. at VCC = 2.3V
VI = 0
Typ. at VCC = 2.5V
RON(3)
VCC = 3V
VI = 2.4V
Ω
NOTES:
1. Typical values are at 3.3V, +25°C ambient.
2. The increase in supply current is attributable to each input that is at the specified voltage level rather than VCC or GND.
3. This is measured by the voltage drop between the A and B terminals at the indicated current through the switch.
SWITCHING CHARACTERISTICS
VCC = 2.5V ± 0.2V
Symbol
tPD(1)
Parameter
Propagation Delay
VCC = 3.3V ± 0.3V
Min.
Max.
Min.
Max.
Unit
—
0.15
—
0.25
ns
3
11.1
3
8.8
ns
3
10.9
3
8.6
ns
1
8.7
2
8.8
ns
A to B or B to A
tPD
Propagation Delay
S to A or B
tEN
Output Enable Time
S to A or B
tDIS
Output DisableTime
S to A or B
NOTE:
1. The propagation delay is the calculated RC time constant of the typical on-state resistance of the switch and the specified load capacitance when driven by an ideal voltage source
(zero output impededance).
3
IDT74CBTLV16212
LOW-VOLTAGE 24-BIT BUS EXCHANGE SWITCH
INDUSTRIAL TEMPERATURE RANGE
TEST CIRCUITS AND WAVEFORMS
TEST CONDITIONS
Symbol
VCC(1)= 3.3V±0.3V
VCC(2)= 2.5V±0.2V
Unit
VLOAD
6
2 x Vcc
V
VIH
3
Vcc
V
VT
1.5
Vcc / 2
V
VLZ
300
150
mV
VHZ
300
150
mV
CL
50
30
pF
SAME PHASE
INPUT TRANSITION
tPLH
tPHL
tPLH
tPHL
OUTPUT
VIH
VT
0V
VOH
VT
VOL
VIH
VT
0V
OPPOSITE PHASE
INPUT TRANSITION
Propagation Delay
VLOAD
VCC
500Ω
Pulse(1, 2)
Generator
VIN
CONTROL
INPUT
GND
tPZL
VOUT
D.U.T.
RT
DISABLE
ENABLE
Open
OUTPUT
SWITCH
NORMALLY
CLOSED
LOW
tPZH
OUTPUT SWITCH
NORMALLY
OPEN
HIGH
500Ω
CL
Test Circuits for All Outputs
SWITCH POSITION
Switch
VLOAD
tPHZ/tPZH
GND
tPD
Open
tPHZ
VT
0V
Enable and Disable Times
NOTES:
1. Pulse Generator for All Pulses: Rate ≤ 10MHz; tF ≤ 2.5ns; tR ≤ 2.5ns.
2. Pulse Generator for All Pulses: Rate ≤ 10MHz; tF ≤ 2ns; tR ≤ 2ns.
Test
VLOAD/2
VT
VLOAD/2
VOL + VLZ
VOL
VOH
VOH -VHZ
0V
NOTE:
1. Diagram shown for input Control Enable-LOW and input Control Disable-HIGH.
DEFINITIONS:
CL = Load capacitance: includes jig and probe capacitance.
RT = Termination resistance: should be equal to ZOUT of the Pulse Generator.
tPLZ/tPZL
tPLZ
VIH
VT
0V
4
IDT74CBTLV16212
LOW-VOLTAGE 24-BIT BUS EXCHANGE SWITCH
INDUSTRIAL TEMPERATURE RANGE
ORDERING INFORMATION
XXX
XX
CBTLV
IDT
XX
Package
Device Type
Temp. Range
CORPORATE HEADQUARTERS
2975 Stender Way
Santa Clara, CA 95054
PV
PA
PAG
PF
Shrink Small Outline Package
Thin Shrink Small Outline Package
TSSOP - Green
Thin Very Small Outline Package
16212
Low-Voltage 24-Bit Bus Exchange Switch
74
–40°C to +85°C
for SALES:
800-345-7015 or 408-727-6116
fax: 408-492-8674
www.idt.com
5
for Tech Support:
[email protected]
(408) 654-6459