4 3 2 LOCKWASHER SEATED ON THE INNER SURFACE OF H BEZEL, SEE NOTE 12 BEZEL, BLACK PLASTIC, WHITE LETTERING SEE NOTE 12 D 1 HOUSING, BLACK PLASTIC LOCK WASHER, 2 REQ'D HEX NUT, BRASS, 2 REQ'D, SEE NOTE 12 HEX NUT, BRASS, 2 REQ'D BEZEL, SEE NOTE 12 STUD, COPPER, 3/8-24, 2 PL CAP & SCREW, SEE NOTES 12 & 13 BEZEL, SEE NOTE 12 F KNOB, RED PLASTIC, POINTER WHITE SEE NOTE 12 E B B 1.69 [42.9] H 2.59 [65.8] B 0.200 [5.08] 0.450 [11.43] 1.375 [34.93] 0.900 [22.86] 0.47 [11.9] MOUNTING STEM & PIN, ZINC DIE CAST NOTES: 1. ALL DIMENSIONS ARE REFERENCE ONLY 2. ALL STEEL PARTS PLATED 3. CONTACT SURFACES COPPER 4. RECOMMENDED LOCK SHANK SIZE 5/16" (0.312[7.93]) DIA 5. TESTED TO IP68 6. RATINGS:CONTINUOUS DUTY:12 Vdc: 300 AMPS; 24 Vdc: 250 AMPS; 36 Vdc: 200 AMPS INTERMITTENT DUTY: 1000 AMPS FOR 90 SECONDS ON; 5 MINUTES OFF 2000 AMPS FOR 30 SECONDS ON; 5 MINUTES OFF 7. SWITCH MUST BE INSTALLED WITH BEZEL 8. CUSTOMER SUPPLIED TERMINALS SHOULD BE IN DIRECT CONTACT WITH BASE OF STUD 9. MAX. STUD TORQUE 70-90 IN-LBS [7.9-10.1 N.m] 10 MOUNTING STEM HEX NUT TORQUE 18 FT LBS [24.4 N.m] 11. PANEL THICKNESS RANGE: 0.032-0.450 [0.81-11.43] 12. PARTS SHIPPED BAGGED D 13. FOR ADDITIONAL KNOB RETENTION, ASSEMBLE SCREW TO SHAFT THEN INSERT CAP, ASSEMBLE SCREW TO SHAFT THEN INSERT CAP H NORMAL AND DOES NOT EFFECT OPERATION OR SEALING 2.28 [58.0] MOUNTING PATTERNS E 0.250 [6.35] 0.750 [19.05] 0.670 [17.02] 0.812 [20.62] 0.813 [20.64] 1.000 [25.40] A MOUNTING STEM, 3/4-16 PERMANENT MARK DATE CODE IN THIS AREA 0.670 [17.02] Revision Control Record Rev. Description of Change A RELEASED DRAWING B ADD DATE CODE C ECN No. 08204 Rev. Date 1/2/08 08362 07/08/08 08373 07/16/08 NOTE 12 D ADDED CAP & SCREW & NOTE 13 08773 4 Description of Change ECN No. E CORRECTED VIEW| ADDED NOTE 09280 F G H CHANGED SCREWS, GASKET, O-RING CHANGE TO IP68 ADD CE MARK & NOTE 11268 Date 4/29/09 08/02/11 12252 08/09/12 09525 09/30/13 Tolerances Unless otherwise specifically noted, the following are default tolerances; 2-places +/- 0.02" 3 Angular +/- 1 Metric: Shown in [ ] refers to equivalent English Dim Tol "REF." or an Asterisk (*) = Non-Toleranced Reference Dimension, shown for clarification purposes only. NOTE: All tolerances are Non-Cumulative. FORM CHT-6 (2/07) 12/8/08 3-places +/- 0.005" Used On or Ref.: EX28369 Special Characteristics: PROPRIETARY INFORMATION This Engineering Drawing, and the Critical Characteristic, relating to information contained herein, is CC Safety and/or Regulatory Compliance proprietary to Cole Hersee Company and may not be disclosed, re-produced, or in Significant Characteristic relating to X any other way transferred or Process Control communicated to any other party without Control Dimension relating to Form the express written consent of an authorized representative of Cole Hersee KC Fit - Function as defined by Cole Hersee Company and/or the Customer Company. Scale: 1:1 Drawn By: 2 DPS Date Drawn: 1/2/08 Pg. 1 of 1 Cole Hersee Co. 20 Old Colony Ave., South Boston, MA, 02127 R Description: Drawing / Part No.: Phn: 617-268-2100 Web: www.colehersee.com SW,ROT,MAST DISC 75920 1 Current Rev. H A 4 3 2 HOUSING, BLACK PLASTIC LOCKWASHER SEATED ON THE INNER SURFACE OF BEZEL, SEE NOTE 12 C BEZEL, BLACK PLASTIC, WHITE LETTERING SEE NOTE 12 1 LOCK WASHER, 2 REQ'D HEX NUT, BRASS, 2 REQ'D HEX NUT, BRASS, 2 REQ'D, SEE NOTE 12 STUD, COPPER, 3/8-24, 2 PL CAP & SCREW, SEE NOTES 12 & 13 KNOB, RED WITH WHITE POINTER NOTE 12 B 1.69 [42.9] C 2.56 [65.0] 0.200 [5.08] 0.450 [11.43] 1.375 [34.93] 0.900 [22.86] 0.47 [11.9] MOUNTING STEM & PIN, ZINC DIE CAST NOTES: 1. ALL DIMENSIONS ARE REFERENCE ONLY 2. ALL STEEL PARTS PLATED 3. CONTACT SURFACES COPPER 4. RECOMMENDED LOCK SHANK SIZE 5/16" (0.312[7.93]) DIA 5. TESTED TO IP68 6. RATINGS: CONTINUOUS DUTY: 12 Vdc: 300 AMPS; 24 Vdc: 250 AMPS; 36 Vdc: 200 AMPS INTERMITTENT DUTY: 1000 AMPS FOR 90 SECONDS ON; 5 MINUTES OFF 2000 AMPS FOR 30 SECONDS ON; 5 MINUTES OFF 7. SWITCH MUST BE INSTALLED WITH BEZEL 8. CUSTOMER SUPPLIED TERMINALS SHOULD BE IN DIRECT CONTACT WITH BASE OF STUD 9. STUD TORQUE 70-90 IN-LBS [7.9-10.1 N.m] 10. MOUNTING STEM HEX NUT TORQUE 18 FT LBS [24.4 N.m] 11. PANEL THICKNESS RANGE: 0.032-0.450 [0.81-11.43] 12. PARTS SHIPPED BAGGED 13. FOR ADDITIONAL KNOB RETENTION, ASSEMBLE SCREW TO SHAFT THEN INSERT CAP 2.34 [59.5] MOUNTING PATTERNS 0.670 [17.02] 0.250 [6.35] 0.750 [19.05] 0.812 [20.62] 0.813 [20.64] 1.000 [25.40] MOUNTING STEM, 3/4-16 Revision Control Record Rev. Rev. Description of Change ECN No. Date A RELEASED DRAWING 11265 8/16/11 B CHANGE TO IP68 12252 08/09/12 C ADD CE MARK & NOTE 09529 09/30/13 Description of Change ECN No. Date Tolerances Unless otherwise specifically noted, the following are default tolerances; 2-places +/- 0.02" 3-places +/- 0.005" Angular +/- 1 Metric: Shown in [ ] refers to equivalent English Dim Tol "REF." or an Asterisk (*) = Non-Toleranced Reference Dimension, shown for clarification purposes only. NOTE: All tolerances are Non-Cumulative. FORM CHT-6 (2/07) 4 C PERMANENT MARK DATE CODE IN THIS AREA 0.670 [17.02] 3 Used On or Ref.: 75920, EX28670 NORMAL AND DOES NOT EFFECT OPERATION OR SEALING PROPRIETARY INFORMATION This Engineering Drawing, and the information contained herein, is proprietary to Cole Hersee Company and may not be disclosed, re-produced, or in any other way transferred or communicated to any other party without the express written consent of an authorized representative of Cole Hersee Company. Scale: 1:1 Drawn By: 2 A DPS Special Characteristics: Cole Hersee Co. Critical Characteristic, relating to CC Safety and/or Regulatory Compliance X Significant Characteristic relating to Process Control Control Dimension relating to Form Fit - Function as defined by Cole KC Hersee Company and/or the Customer Date Drawn: 4/6/11 Pg. 1 of 1 20 Old Colony Ave., South Boston, MA, 02127 R Description: Drawing / Part No.: Phn: 617-268-2100 Web: www.colehersee.com SW,ROT,MAST DISC 75920-05 1 Current Rev. C 4 3 BEZEL, BLACK PLASTIC, WHITE LETTERING SEE NOTE 12 2 LOCKWASHER SEATED ON THE INNER SURFACE OF B BEZEL, SEE NOTE 12 1 HOUSING, BLACK PLASTIC LOCK WASHER, STAINLESS STEEL, 2 REQ'D HEX NUT, BRASS, 2 REQ'D, SEE NOTE 12 HEX NUT, STAINLESS STEEL, 2 REQ'D STUD, COPPER, TIN PLATED, 3/8-24, 2 PL CAP & SCREW, SEE NOTES 12 & 13 KNOB, RED WITH WHITE POINTER NOTE 12 B 1.69 [42.9] B 2.56 [65.0] 0.200 [5.08] 0.450 [11.43] 1.375 [34.93] 0.900 [22.86] 0.47 [11.9] MOUNTING STEM & PIN, ZINC DIE CAST NOTES: 1. ALL DIMENSIONS ARE REFERENCE ONLY 2. ALL STEEL PARTS PLATED 3. CONTACT SURFACES COPPER 4. RECOMMENDED LOCK SHANK SIZE 5/16" (0.312[7.93]) DIA 5. TESTED TO IP68 6. RATINGS: CONTINUOUS DUTY: 12 Vdc: 300 AMPS; 24 Vdc: 250 AMPS; 36 Vdc: 200 AMPS INTERMITTENT DUTY: 1000 AMPS FOR 90 SECONDS ON; 5 MINUTES OFF 2000 AMPS FOR 30 SECONDS ON; 5 MINUTES OFF 7. SWITCH MUST BE INSTALLED WITH BEZEL 8. CUSTOMER SUPPLIED TERMINALS SHOULD BE IN DIRECT CONTACT WITH BASE OF STUD 9. STUD TORQUE 70-90 IN-LBS [7.9-10.1 N.m] 10. MOUNTING STEM HEX NUT TORQUE 18 FT LBS [24.4 N.m] 11. PANEL THICKNESS RANGE: 0.032-0.450 [0.81-11.43] 12. PARTS SHIPPED BAGGED 13. FOR ADDITIONAL KNOB RETENTION, ASSEMBLE SCREW TO SHAFT THEN INSERT CAP 2.34 [59.5] MOUNTING PATTERNS 0.670 [17.02] 0.250 [6.35] 0.750 [19.05] 0.812 [20.62] 0.813 [20.64] 1.000 [25.40] MOUNTING STEM, 3/4-16 PERMANENT MARK DATE CODE IN THIS AREA 0.670 [17.02] Revision Control Record Rev. Description of Change ECN No. Date Tolerances Unless otherwise specifically noted, the following are default tolerances; 2-places +/- 0.02" 3-places +/- 0.005" Angular +/- 1 Rev. Description of Change ECN No. Date A ADD STAINLESS STEEL HARDWARE 12328 10/29/12 "REF." or an Asterisk (*) = Non-Toleranced Reference Dimension, shown for clarification purposes only. B ADD CE MARK & NOTE 09525 09/30/13 NOTE: All tolerances are Non-Cumulative. Metric: Shown in [ ] refers to equivalent English Dim Tol FORM CHT-6 (2/07) 4 3 Used On or Ref.: 75920, EX28988 B PROPRIETARY INFORMATION This Engineering Drawing, and the information contained herein, is proprietary to Cole Hersee Company and may not be disclosed, re-produced, or in any other way transferred or communicated to any other party without the express written consent of an authorized representative of Cole Hersee Company. Scale: 1:1 Drawn By: 2 DPS NORMAL AND DOES NOT EFFECT OPERATION OR SEALING Special Characteristics: Cole Hersee Co. Critical Characteristic, relating to CC Safety and/or Regulatory Compliance X Significant Characteristic relating to Process Control Control Dimension relating to Form Fit - Function as defined by Cole KC Hersee Company and/or the Customer Date Drawn: 9/4/12 Pg. 1 of 1 20 Old Colony Ave., South Boston, MA, 02127 R Description: Drawing / Part No.: Phn: 617-268-2100 Web: www.colehersee.com SW,ROT,MAST DISC 75920-10 1 Current Rev. B A