MM8xMS-3 -14

Model MM8xMS-3
Model MM8xMS-14
Double Balanced Mixer
RF 5.0 to 15.0 GHz
Multi-Octave Band
Electrical Specifications: (1)
Specifications
Conditions
Parameter
SSB Conversion
loss: (2) (3)
Isolation
LO to RF:
RF (GHz) LO (GHz)
5.5-14.5
6.0-14.0
4.0-15.0
5.0-14.0
3.0-16.0
5.0-14.0
3.0-17.0
5.0-15.0
IF (MHz)
DC-500
DC-1000
DC-2000
DC-2000
3.0-7.0
7.0-17.0
3.0-7.0
7.0-17.0
LO to IF:
Min
16
23
15
25
RF to IF:
Input 1 dB
Compression Point:
5.0-15.0
5.0-15.0
3.0-17.0
DC-1500
Input Third Order
Intercept Point:
5.0-15.0
3.0-17.0
DC-1500
LO Power: (4)
5.0-15.0
3.0-17.0
DC-1500
dB
dB
dB
dB
Typical
5.2 dB
6.5 dB
7.0 dB
8.5 dB
Max
7.0 dB
8.5 dB
9.5 dB
10.0 dB
24 dB
32 dB
18 dB
39 dB
21 dB
+2 dBm
+5 dBm
+8 dBm
+11 dBm
+14 dBm
+18 dBm
+7 dBm
+10 dBm
+14 dBm
MM83
MM84
MM86
MM83
MM84
MM86
MM83
MM84
MM86
Model MM8xMS-3
Model MM8xMS-14
LO Power
3 = +7 dBm
4 = +10 dBm
6 = +14 dBm
Notes:
1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the nominal LO power. Specifications indicated as typical are not guaranteed.
2. Noise figure is typically within ±0.5 dB of conversion loss for IF frequencies greater than 10 MHz.
3. Conversion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C.
4. Usable LO drives are up to 2 dB below and 3 dB above nominal.
5. See Application Note M112, for aid in selecting the outline and for mounting and installation information.
MM8xMS-3
Outline: MS3C
MM8xMS-14
Outline: MS3D
Typical
Performance
at 25˚C
All dimensions are in inches and [mm].
Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, FL 32905 · PH (888) 553-7531 · Fax (888) 553-7532
www.SpectrumMicrowave.com Spectrum Microwave · 2707 Black Lake Place · Philadelphia, PA 19154 · PH (215) 464-4000 · Fax (215) 464-4001
Rev.
3/6/08