Model MM8xMS-3 Model MM8xMS-14 Double Balanced Mixer RF 5.0 to 15.0 GHz Multi-Octave Band Electrical Specifications: (1) Specifications Conditions Parameter SSB Conversion loss: (2) (3) Isolation LO to RF: RF (GHz) LO (GHz) 5.5-14.5 6.0-14.0 4.0-15.0 5.0-14.0 3.0-16.0 5.0-14.0 3.0-17.0 5.0-15.0 IF (MHz) DC-500 DC-1000 DC-2000 DC-2000 3.0-7.0 7.0-17.0 3.0-7.0 7.0-17.0 LO to IF: Min 16 23 15 25 RF to IF: Input 1 dB Compression Point: 5.0-15.0 5.0-15.0 3.0-17.0 DC-1500 Input Third Order Intercept Point: 5.0-15.0 3.0-17.0 DC-1500 LO Power: (4) 5.0-15.0 3.0-17.0 DC-1500 dB dB dB dB Typical 5.2 dB 6.5 dB 7.0 dB 8.5 dB Max 7.0 dB 8.5 dB 9.5 dB 10.0 dB 24 dB 32 dB 18 dB 39 dB 21 dB +2 dBm +5 dBm +8 dBm +11 dBm +14 dBm +18 dBm +7 dBm +10 dBm +14 dBm MM83 MM84 MM86 MM83 MM84 MM86 MM83 MM84 MM86 Model MM8xMS-3 Model MM8xMS-14 LO Power 3 = +7 dBm 4 = +10 dBm 6 = +14 dBm Notes: 1. Specifications are guaranteed when tested as a downconverter in a 50 Ohm system at +25˚C with the nominal LO power. Specifications indicated as typical are not guaranteed. 2. Noise figure is typically within ±0.5 dB of conversion loss for IF frequencies greater than 10 MHz. 3. Conversion loss typically degrades less than 0.5 dB at +100˚C and improves less than 0.5 dB at -55˚C. 4. Usable LO drives are up to 2 dB below and 3 dB above nominal. 5. See Application Note M112, for aid in selecting the outline and for mounting and installation information. MM8xMS-3 Outline: MS3C MM8xMS-14 Outline: MS3D Typical Performance at 25˚C All dimensions are in inches and [mm]. Spectrum Microwave · 2144 Franklin Drive N.E. · Palm Bay, FL 32905 · PH (888) 553-7531 · Fax (888) 553-7532 www.SpectrumMicrowave.com Spectrum Microwave · 2707 Black Lake Place · Philadelphia, PA 19154 · PH (215) 464-4000 · Fax (215) 464-4001 Rev. 3/6/08