AXLE145

 Rev.: 1 Specification AXLE145 Oscillator type: SMD (VC)TCXO in CO 26 or CO27 package
Parameter Frequency range min. 10
10 1 Frequency stability vs. operating temperature range vs. supply voltage variation vs. load change Long term (aging) per year Frequency adjustment range Mechanical (internal trimmer) Electronic Frequency Control (EFC) EFC voltage VC EFC slope (f / VC) EFC input impedance RF output Signal waveform Load Amplitude Supply voltage VS Current consumption (Note 2) Enclosure (see drawing) (LxWxH) (Note 3) Weight Packing Notes: 1.
2.
3.
4.
typ. max. Unit 50
50 800 ±0.5 to ±5
See tables 1 & 2 ±0.1
±0.3
±0.2
±1
±3
±5
0.15
0.5 1.65
2.5 Positive
3.15
4.5 100
MHz
MHz Date: 2015‐10‐07 Condition ppm
ppm
Clipped Sine wave
Sine wave HCMOS, PECL, LVDS Option 4 & 5 ppm
ppm
ppm
VS ±5 % Load ±10 % @+40°C ppm
ppm
V
V Option 1 = blank Option 1 = “V” Option 2 = “3” Option 2 = “5” kΩ
Clipped Sine wave
Sine wave HCMOS PECL LVDS 10 kΩ || 10 pF
50 Ω 15 pF 50 Ω + Bias 0.8
V p‐p
1.0 V p‐p 0 dBm +10 dBm According to relevant Logic Standard
3.15
3.3
3.45
V
4.75 5.0 5.25 V 2 ~ 30
mA
12 ~ 30 mA 15 ~ 50 mA 25 ~ 100 mA Option 3 = “C” Option 3 = “S” Option 3 = “H” Option 3 = “P” Option 3 = “L” Option 3 = “C” Option 3 = “S” Option 3 = “H” Option 3 = “P” or “L” Option 3 = “C” / 3.3 V
Option 3 = “C” / 5.0 V Option 3 = “S” / 3.3 V Option 3 = “S” / 5.0 V Option 3 = “H”, “P”, “L”
Option 2 = “3” Option 2 = “5” Option 3 = “C” Option 3 = “S” Option 3 = “H” Option 3 = “P” or “L” 14.8x9.2x5.5 max.
Package option “A”: 4‐pad Package option “B”: 6‐pad 2
Tape & Reel
IEC 61837 CO 26 (4‐pad) or CO 27 (6‐pad) IEC 60286‐3 mm
g
Terminology and test conditions are according to IEC60679‐1 and MIL‐PRF‐55310, unless otherwise stated Depending on frequency and supply voltage The 6‐pad version CO 27 is needed for LVDS and PECL output All combinations of options might not be available. Please consult factory GmbH & Co. KG
Roemerring 9 D‐74821 Mosbach Germany AXLE145 Rev.1 Drawing D3 Page 1(4) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E‐mail: [email protected] Absolute Maximum Ratings Parameter min.
max.
Supply Voltage VS Control Voltage VC Storage Temperature ‐0.5
‐0.5
‐55
VS + 10%
6
+105
Unit
Condition V
V
°C
VS to GND VC to GND Frequency stability vs. temperature Option 4 05 10 15 20 25 30 35 50 Table 1 Stability [ppm] ±0.5 ±1.0 ±1.5 ±2.0 ±2.5 ±3.0 ±3.5 ±5.0 Lower Temperature
Option 5
T [°C]
0 0
1 ‐10
2 ‐20
3 ‐30
4 ‐40
Table 2 Upper Temperature Option 5
T [°C] A
+50
B
+60
C
+70
D
+75
E
+80
F
+85
Ordering Code Option 2
Option 3
Option 4
[Supply [RF [Stability] Voltage] output] AXLE145 A or B _ or “V” 3 or 5
C, S, H, P, L
Table 1
*Package option “A” = standard, except for PECL and LVDS output Example: AXLE145A‐V‐5‐S‐10‐3D_Rev.1 – 10.000 MHz Model Package option* Option 1 [EFC]* Option 5 [Temperature Revision Frequency [MHz] range] Table 2 Rev.1 10.000
Handling and Testing Parameter Procedure
Handling and Testing Processing Parameter Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS compliant Application Note AXAN‐011
Application Note AXAN‐012
Procedure
IEC60749‐26
HBM
IEC60749‐27
MM
 Yes  No
 Yes  No
Source www.axtal.com www.axtal.com Condition 2000 V 200 V GmbH & Co. KG
Roemerring 9 D‐74821 Mosbach Germany AXLE145 Rev.1 Drawing D3 Page 2(4) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E‐mail: [email protected] Enclosure drawing Pin connections Pin #
1
2*
3
4
5*
Symbol
N.C. or
VC
N.C.
GND
RF OUT
N.C. or Comp OUT Function No Connection or Control Voltage (EFC) No Connection Ground RF Output No Connection or Complementary RF Output (PECL and LVDS) Supply Voltage 6
VS
*Pins #2 and #5 not present for package option “A” Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2‐17 IEC 60679‐1 Clause 5.6.2 MIL‐STD‐ 202G Method 112E MIL‐STD‐ 810F Method MIL‐PRF‐ 55310D Clause 3.6.1.2 2‐20 2‐58 5.6.3 208H 210F 3.6.52 3.6.48 2‐27 5.6.8 213B 516.4 3.6.40 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half‐sine pulse Test Fc, 30 min per axes, 10 Hz ‐ 55 Hz 0,75mm; 55 Hz ‐ 2 kHz, 10g Test Fdb Vibration, 2‐6 5.6.7.1 201A 516.4‐4 3.6.38.1 sinusoidal* 204D 3.6.38.2 Vibration, 2‐64 5.6.7.3 214A 514.5 3.6.38.3 random* 3.6.38.4 Endurance tests 108A ‐ ageing 5.7.1 4.8.35 30 days @ 85°C, OCXO @25°C ‐ extended aging 5.7.2 1000h, 2000h, 8000h @85°C Other environmental conditions on request Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. GmbH & Co. KG
Roemerring 9 D‐74821 Mosbach Germany AXLE145 Rev.1 Drawing D3 Page 3(4) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E‐mail: [email protected] Revision History Rev. Drawing Date [dd.mm.yyyy] 1 1 1 D1 D2 D3 01.10.2012 06.04.2014 07.10.2015 GmbH & Co. KG
Roemerring 9 D‐74821 Mosbach Germany Remarks Editorial changes AXLE145B Environmental conditions updated, editorial changes Clarification package options A (CO 26) and B (CO 27) AXLE145 Rev.1 Drawing D3 Page 4(4) Author Checked BN HH BN BN HH BN ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E‐mail: [email protected]