Specification Oscillator type: Parameter Frequency range min. Long term (aging) per year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC ±50 ±100 ±150 0.15 0 Load Amplitude Supply voltage VS Current consumption (Note 3) Enclosure (see drawing) (LxWxH) Weight Packing 4. Date: 2014-04-05 max. Unit Condition 190 800 MHz MHz ppm ppm ppm Sine wave HCMOS, PECL, LVDS ±10 to ±100 See tables 1 & 2 EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform typ. 6 1 Frequency stability Overall stability vs. operating temperature range Notes: 1. 2. 3. Rev.: 2 AXIS207 VCXO in DIL14 package 1.65 2.5 Positive Negative ±3 ppm 3.15 5 ppm ppm ppm V V 100 Option 3 & 4 Option 5 = “5” Option 5 = “10” Option 5 = “15” Option 1 = “3” Option 1 = “5” Option 6 = blank Option 6 = “N” (Note 2) kΩ Sine wave HCMOS PECL LVDS 50 Ω 15 pF 50 Ω + Bias 0 dBm +10 dBm According to relevant Logic Standard 3.15 3.3 3.45 V 4.75 5.0 5.25 V 15 ~ 70 mA 15 ~ 100 mA 25 ~ 100 mA 20.7x13.1x7.5 max. 5 Palette or Tube mm g Option 2 = “S” Option 2 = “H” Option 2 = “P” Option 2 = “L” Option 2 = “S” Option 2 = “H” Option 2 = “P” or “L” Option 2 = “S” / 3.3 V Option 2 = “S” / 5.0 V Option 2 = “H”, “P”, “L” Option 1 = “3” Option 1 = “5” Option 2 = “S” Option 2 = “H” Option 2 = “P” or “L” IEC 60679-3 CO 02 IEC 60286-3 Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Negative slope only available for HCMOS Output version (Option 2 = “H”) Depending on frequency and supply voltage All combinations of options might not be available. Please consult factory GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIS207 Rev.2 Drawing D2 Page 1(3) www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -45 VS + 10% 6 +90 Unit Condition V V °C VS to GND VC to GND Frequency stability vs. temperature Option 3 10 15 20 30 50 100 Table 1 Stability [ppm] ±10 ±15 ±20 ±30 ±50 ±100 Lower Temperature Option 4 T [°C] 0 0 1 -10 2 -20 3 -30 4 -40 Upper Temperature Option 4 T [°C] A +50 B +60 C +70 D +75 E +80 F +85 Ordering Code Model AXIS207 Option 1 [Supply Voltage] 3 or 5 Option 2 [RF output] Option 3 [Stability] S, H, P, L Table 1 Option 4 [Temperature range] Table 2 Option 5 Option 6 Revision Frequency [MHz] [Tuning Range] [Tuning slope] 5, 10, 15 _ or “N” Rev.2 10.000 Example: AXIS207-5-S-10-1B-N_Rev.2 – 10.000 MHz Handling and Testing Parameter Procedure Handling and Testing Processing Parameter Application Note AXAN-011 Application Note AXAN-012 Procedure Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS compliant GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany IEC60749-26 IEC60749-27 Yes Yes AXIS207 Rev.2 Drawing D2 Page 2(3) HBM MM No No Source www.axtal.com www.axtal.com Condition 2000 V 200 V www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin connections Sine wave and HCMOS Output: Pin # 1 7 8 9 14 Symbol VC GND RF OUT Vs Function Voltage Control (EFC) Ground RF Output - Pin Not Present Supply Voltage PECL and LVDS Output: Pin # 1 7 8 9 14 Symbol VC GND RF OUT Comp OUT Vs Function Voltage Control (EFC) Ground RF Output Complementary RF Output Supply Voltage Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] 2 2 D1 D2 01.10.2012 05.04.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Editorial changes Environmental conditions updated, editorial changes AXIS207 Rev.2 Drawing D2 Page 3(3) Author Checked BN HH BN HH www.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]