Specification Oscillator type: Parameter Frequency range min. vs. supply voltage variation vs. load change Long term (aging) per year Frequency adjustment range Mechanical (internal trimmer) Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load Amplitude Supply voltage VS Current consumption (Note 2) Enclosure (see drawing) (LxWxH) (Note 3) Weight Packing typ. 6 6 1 Frequency stability vs. operating temperature range Notes: 1. 2. 3. 4. Rev.: 1 AXLE207M (VC)TCXO in DIL14 package max. Unit Condition 190 190 800 MHz MHz Clipped Sine wave Sine wave HCMOS, PECL, LVDS ±0.5 to ±5 See tables 1 & 2 ±0.1 ±0.3 ±0.2 ±1 ±3 ±5 0.15 0.5 1.65 2.5 Positive Date: 2014-04-06 3.15 4.5 100 ppm ppm Option 4 & 5 ppm ppm ppm VS ±5 % Load ±10 % @+40°C ppm ppm V V Option 1 = blank Option 1 = “V” Option 2 = “3” Option 2 = “5” kΩ Clipped Sine wave Sine wave HCMOS PECL LVDS 10 kΩ || 10 pF 50 Ω 15 pF 50 Ω + Bias 0.8 V p-p 1.0 V p-p 0 dBm +10 dBm According to relevant Logic Standard 3.15 3.3 3.45 V 4.75 5.0 5.25 V 2 ~ 30 mA 12 ~ 30 mA 15 ~ 50 mA 25 ~ 100 mA 20.7x13.1x7.5 max. 5 Palette mm g Option 3 = “C” Option 3 = “S” Option 3 = “H” Option 3 = “P” Option 3 = “L” Option 3 = “C” Option 3 = “S” Option 3 = “H” Option 3 = “P” or “L” Option 3 = “C” / 3.3 V Option 3 = “C” / 5.0 V Option 3 = “S” / 3.3 V Option 3 = “S” / 5.0 V Option 3 = “H”, “P”, “L” Option 2 = “3” Option 2 = “5” Option 3 = “C” Option 3 = “S” Option 3 = “H” Option 3 = “P” or “L” IEC 60679-3 CO 02 IEC 60286-3 Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Depending on frequency and supply voltage Reduced package height H = 5.1 mm max. on request All combinations of options might not be available. Please consult factory GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXLE207M Rev.1 Drawing D2 Page 1(4) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -55 VS + 10% 6 +105 Unit Condition V V °C VS to GND VC to GND Frequency stability vs. temperature Option 4 05 10 15 20 25 30 35 50 Table 1 Stability [ppm] ±0.5 ±1.0 ±1.5 ±2.0 ±2.5 ±3.0 ±3.5 ±5.0 Lower Temperature Option 5 T [°C] 0 0 1 -10 2 -20 3 -30 4 -40 Upper Temperature Option 5 T [°C] A +50 B +60 C +70 D +75 E +80 F +85 Table 2 Ordering Code Option 2 Option 3 Option 4 [Supply [RF [Stability] Voltage] output] AXLE207M _ or “V” 3 or 5 C, S, H, P, L Table 1 Example: AXLE207M-V-5-S-10-3D_Rev.1 – 10.000 MHz Model Option 1 [EFC]* Option 5 [Temperature range] Table 2 Revision Frequency [MHz] Rev.1 10.000 Handling and Testing Parameter Procedure Handling and Testing Processing Parameter Application Note AXAN-011 Application Note AXAN-012 Procedure Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS compliant GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany IEC60749-26 IEC60749-27 Yes Yes AXLE207M Rev.1 Drawing D2 Page 2(4) HBM MM No No Source www.axtal.com www.axtal.com Condition 2000 V 200 V ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Enclosure drawing Pin connections (Without EFC) Pin # 1 7 8 9 14 Symbol Function N.C. or No Connection or Comp OUT Complementary RF Output (PECL and LVDS) GND Ground RF OUT RF Output - Pin Not Present VS Supply Voltage Pin connections (With EFC) Pin # 1 7 8 9 Symbol VC GND RF OUT Comp OUT 14 VS Function Control Voltage (EFC) Ground RF Output Complementary RF Output (PECL and LVDS) Supply Voltage * PECL and LVDS output with EFC Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXLE207M Rev.1 Drawing D2 Page 3(4) ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Revision History Rev. Drawing Date [dd.mm.yyyy] 1 1 D1 D2 01.10.2012 06.04.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks Editorial changes Environmental conditions updated, editorial changes AXLE207M Rev.1 Drawing D2 Page 4(4) Author Checked BN HH BN HH ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]