Specification Oscillator type: Parameter Frequency range min. Long term (aging) per year Frequency adjustment range Electronic Frequency Control (EFC) EFC voltage VC EFC slope (∆f / ∆VC) EFC input impedance RF output Signal waveform Load Amplitude Supply voltage VS Current consumption (Note 2) Enclosure (see drawing) (LxWxH) Weight Packing typ. Unit Condition 50 150 MHz MHz ppm ppm ppm Sine wave HCMOS ±10 to ±100 See tables 1 & 2 ±50 ±100 ±150 0.15 0 1.65 2.5 Positive Date: 2014-04-05 max. 10 1 Frequency stability Overall stability vs. operating temperature range Notes: 1. 2. 3. Rev.: 1 AXIS135M VCXO in DIL8 package ±3 ppm 3.15 5 ppm ppm ppm V V 100 Option 3 & 4 Option 5 = “5” Option 5 = “10” Option 5 = “15” Option 1 = “3” Option 1 = “5” kΩ Sine wave HCMOS 50 Ω 15 pF 0 dBm +10 dBm According to relevant Logic Standard 3.15 3.3 3.45 V 4.75 5.0 5.25 V 15 ~ 70 mA 15 ~ 100 mA 12.7x12.7x5.1 max. mm g 4 Tube or Pallet Option 2 = “S” Option 2 = “H” Option 2 = “S” Option 2 = “H” Option 2 = “S” / 3.3 V Option 2 = “S” / 5.0 V Option 2 = “H” Option 1 = “3” Option 1 = “5” Option 2 = “S” Option 2 = “H” IEC 60679-3 CO 21 IEC 60286-3 Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise stated Depending on frequency and supply voltage All combinations of options might not be available. Please consult factory Absolute Maximum Ratings Parameter min. max. Supply Voltage VS Control Voltage VC Storage Temperature -0.5 -0.5 -55 VS + 10% 6 +105 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIS135M Rev.1 Drawing D1 Page 1(3) Unit Condition V V °C VS to GND VC to GND ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Frequency stability vs. temperature Option 3 10 15 20 30 50 100 Table 1 Stability [ppm] ±10 ±15 ±20 ±30 ±50 ±100 Lower Temperature Option 4 T [°C] 0 0 1 -10 2 -20 3 -30 4 -40 Upper Temperature Option 4 T [°C] A +50 B +60 C +70 D +75 E +80 F +85 Table 2 Ordering Code Option 1 Option 2 Option 3 [Supply [RF output] [Stability] Voltage] AXIS135M 3 or 5 S or H Table 1 Example: AXIS135M-5-S-10-1B_Rev.1 – 10.000 MHz Model Option 4 [Temperature range] Table 2 Option 5 [Tuning Revision Range] 5, 10, 15 Rev.1 Frequency [MHz] 10.000 Enclosure drawing Pin connections Pin # 1 2 3 4 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany AXIS135M Rev.1 Drawing D1 Page 2(3) Symbol VC GND RF OUT Vs Function Control Voltage (EFC) Ground RF Output Supply Voltage ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected] Handling and Testing Parameter Procedure Handling and Testing Processing Source Application Note AXAN-011 Application Note AXAN-012 Parameter Procedure Electrostatic discharge (ESD) THD devices SMD devices Washable RoHS compliant IEC60749-26 IEC60749-27 Yes Yes www.axtal.com www.axtal.com Condition HBM MM No No 2000 V 200 V Environmental conditions Test Sealing tests (if applicable) Solderability Resistance to soldering heat Shock* IEC 60068 Part … 2-17 IEC 60679-1 Clause 5.6.2 MIL-STD202G Method 112E 2-20 2-58 5.6.3 208H 210F 2-27 5.6.8 213B Vibration, 2-6 5.6.7.1 201A sinusoidal* 204D Vibration, 2-64 5.6.7.3 214A random* Endurance tests 108A - ageing 5.7.1 - extended aging 5.7.2 Other environmental conditions on request MIL-STD810F Method MIL-PRF55310D Clause 3.6.1.2 3.6.52 3.6.48 516.4 3.6.40 516.4-4 3.6.38.1 3.6.38.2 3.6.38.3 3.6.38.4 514.5 4.8.35 Test conditions (IEC) Gross leak: Test Qc, Fine leak: Test Qk Test Ta Method 1 Test Td1 Method 2 Test Td2 Method 2 Test Ea, 3 x per axes 100g, 6 ms half-sine pulse Test Fc, 30 min per axes, 10 Hz - 55 Hz 0,75mm; 55 Hz - 2 kHz, 10g Test Fdb 30 days @ 85°C, OCXO @25°C 1000h, 2000h, 8000h @85°C Data sheet is for information purposes only and may be subject to modifications or may be discontinued without notice. Revision History Rev. Drawing Date [dd.mm.yyyy] 1 1 D0 D1 12.12.2012 05.04.2014 GmbH & Co. KG Roemerring 9 D-74821 Mosbach Germany Remarks First issue Environmental conditions updated, editorial changes AXIS135M Rev.1 Drawing D1 Page 3(3) Author Checked BN HH BN HH ww.axtal.com fon: +49 (6261) 939834 fax: +49 (6261) 939836 E-mail: [email protected]