40 V, 17 A P-channel Trench Power MOSFET with Reverse Battery Protection DJR0417 Data Sheet Description DJR0417 is P-channel trench power MOSFET designed for the load switch of automotive electronic units requiring the reverse battery protection. Since DJR0417 has a bidirectional diode between Drain and Source, the reverse battery protection can be realized with only one load switch. Package TO252 (4) (1) Gate (2)(4) Drain (3) Source Features ● V(BR)DSS ---------------------------- − 40 V (ID = − 100 μA) ● ID ------------------------------------------------------ − 17 A ● RDS(ON) ------ 75 mΩ max. (ID = − 8.5 A, VGS = − 10 V) (1) (2) (3) (3) (2) (1) Not to Scale ● ● ● ● Automotive Qualified Load switch can configure by only one component For reverse battery protection Compliant with RoHS Directive Equivalent circuit S(3) Typical Application Main switch Schottky diode RG G(1) Gate driver Battery 100Ω(typ.) Reverse battery protection Body diode Sub-MOSFET Microcomputer Load D(2)(4) GND Gate driver is not required Application DJR0417 Battery Microcomputer ● Car battery Load GND DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 1 DJR0417 Absolute Maximum Ratings ● Unless otherwise specified, TA = 25 °C Parameter Symbol Test conditions Rating Unit Drain to Source Voltage VDS − 40 V Source to Drain Voltage VSD − 16 V Gate to Source Voltage VGS − 15,+ 0 V TC = 25 °C − 17 A 230 mJ 48 W Continuous Drain Current ID Single Pulse Avalanche Energy EAS VDD = − 15 V, L = 1 mH, IAS = − 17 A, unclamped, Refer to Figure 1 Power Dissipation PD TC = 25 °C Operating Junction Temperature TJ − 55 to 150 °C Storage Temperature Range TSTG − 55 to 150 °C Maximum Drain to Source dv/dt dv/dt 0.075 V/ns Thermal Characteristics ● Unless otherwise specified, TA = 25 °C Parameter Thermal Resistance (Junction to Case) Symbol Test Conditions RθJC Min. Typ. Max. Unit − − 2.6 °C/W Min. Typ. Max. Unit Electrical Characteristic ● Unless otherwise specified, TA = 25 °C Parameter Drain to Source Breakdown Voltage Drain to Source Leakage Current Symbol V(BR)DSS ID = − 100 μA, VGS = 0 V − 40 − − V IDSS VDS = − 40 V, VGS = 0 V − − − 100 µA Gate to Source Leakage Current IGSS VGS = − 15 V − − − 100 µA VDS = − 10 V, ID = − 1 mA − 1.0 − 1.75 − 2.5 V ID = − 8.5 A, VGS = − 10 V − 50 75 mΩ ID = − 5 A, VGS = − 4.5 V − 130 350 mΩ − 75 − − 9 − − 30 − − 90 − − 450 − − 990 − tf VDD = − 15 V ID = − 8.5 A RG = 10 Ω, RL = 1.53 Ω, RGS = 50 Ω VGS = − 10 V Refer to Figure 2 − 910 − V(BR) SD IS = − 1m A, VGS = 0 V − 16 − − Gate Threshold Voltage VGS(th) Static Drain to Source On-Resistance RDS(ON) Total Gate Charge (VGS = 10 V) Qg Gate to Source Charge Qgs Gate to Drain Charge Qgd Turn-On Delay Time td(on) Rise Time Turn-Off Delay Time Fall Time Source to Drain Breakdown Voltage tr td(off) Test Conditions VDS = -15 V ID = − 8.5 A VGS = − 10 V DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 nC ns V 2 DJR0417 Test Circuits and Waveforms E AS V(BR)DSS 1 2 L I AS 2 V(BR)DSS VDD VDS 0 L VDD ID VDS V(BR)DSS S 0V VDD G RG ID 0 D VGS IAS (a) Test Circuit (b) Waveform Figure 1 Unclamped Inductive Switching VGS 0 10% RL 90% VDS RG G VDD 0V RGS VDS S 0 90% D VGS 10% td(on) tr P.W. = 10 μs Duty cycle ≤ 1 % td(off) tf ton (a) Test Circuit toff (b) Waveform Figure 2 Switching Time DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 3 DJR0417 Performance Curves ID-VGS characteristics (typical) ID-VDS characteristics(typical) Tc=25°C - 20 -10V VDS= -10V - 20 -6V -5V - 15 - 15 ID (A) - 10 ID (A) Tc = -55℃ VGS = -4.5V -5 25℃ 85℃ - 10 150℃ -5 0 0 -2 -1 -3 -4 0 -5 -1 0 -4 -3 -2 -5 -6 -7 VGS (V) VDS (V) VDS - VGS characteristics (typical) Vth - TC characteristics (typical) VDS= -10V ID= -1mA - 2.5 -10 -8 -6 Vth(V) VDS (V) - 2.0 - 1.5 -4 ID= -17A - 1.0 ID= -10A -2 ID= -5A 0 0 -5 - 10 - 15 - 0.5 -100 VGS (V) DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 -50 0 50 100 150 200 Tc (°C) 4 DJR0417 RDS(ON)-TC characteristics (typical) VGS-Qg characteristics (typical) ID= -8.5A VGS= -10V 100 Tc=25°C - 10 80 -8 60 -6 VGS (V) RDS (ON) (mΩ) ID= -8.5A VDD= -15V 40 -4 -2 20 0 -100 0 -50 0 50 100 150 200 0 20 40 Tc (°C) 60 80 Qg (nC) V(BR)SD - TC characteristics (typical) V(BR)DSS - TC characteristics (typical) ID= -5mA - 24 ID= -1mA - 60 - 23 - 50 - 21 V(BR)DSS (V) V(BR)SD (V) - 22 - 20 - 19 - 18 - 40 - 30 - 17 - 16 -100 - 20 -50 0 50 100 150 200 -100 Tc (°C) DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 -50 0 50 100 150 200 Tc (°C) 5 DJR0417 ID-TC characteristics EAS-Tc characteristics - 20 250 - 15 150 ID (A) EAS (mJ) 200 - 10 100 -5 50 0 0 25 50 75 100 125 0 150 25 50 75 100 125 150 Tc (°C) Tc (°C) SAFE OPARATING AREA PD-Ta Derating Tc=25°C Single Pulse - 100 60 With infinite heatsink 50 PT=100us - 10 PT=1ms ID (A) PD (W) 40 30 PT=10ms -1 20 RDS(on) LIMITED 10 0 0 25 50 75 100 125 150 - 0.1 - 0.1 Ta (°C) DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 -1 - 10 - 100 VDS (V) 6 DJR0417 Tc=25°C Single Pulse TRANSIENT THERMAL RESISTANCE - PULSE WIDTH 10 Rth (j-c) (°C//W) 1 0.1 0.01 0.00001 0.0001 0.001 0.01 0.1 1 10 P.T. (sec) DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 7 DJR0417 External Dimensions ● TO252 NOTES: ● Dimension is in millimeters ● Pb-free. Device composition compliant with the RoHS directive Marking Diagram DJR0417 Part Number SK YM DD Lot Number Y is the Last digit of the year (0 to 9) M is the Month (1 to 9, O, N or D) DD is the Date (two digit of 01 to 31) DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 8 DJR0417 IMPORTANT NOTES ● All data, illustrations, graphs, tables and any other information included in this document as to Sanken’s products listed herein (the “Sanken Products”) are current as of the date this document is issued. All contents in this document are subject to any change without notice due to improvement, etc. Please make sure that the contents set forth in this document reflect the latest revisions before use. ● The Sanken Products are intended for use as components of electronic equipment or apparatus (transportation equipment and its control systems, home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken. If considering use of the Sanken Products for any applications that require higher reliability (traffic signal control systems or equipment, disaster/crime alarm systems, etc.), you must contact a Sanken sales representative to discuss the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken Products and return them to Sanken, prior to the use of the Sanken Products. Any use of the Sanken Products without the prior written consent of Sanken in any applications where extremely high reliability is required (aerospace equipment, nuclear power control systems, life support systems, etc.) is strictly prohibited. ● In the event of using the Sanken Products by either (i) combining other products or materials therewith or (ii) physically, chemically or otherwise processing or treating the same, you must duly consider all possible risks that may result from all such uses in advance and proceed therewith at your own responsibility. ● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the occurrence of any failure or defect in semiconductor products at a certain rate. You must take, at your own responsibility, preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which the Sanken Products are used, upon due consideration of a failure occurrence rate or derating, etc., in order not to cause any human injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer to the relevant specification documents and Sanken’s official website in relation to derating. ● No anti-radioactive ray design has been adopted for the Sanken Products. ● No contents in this document can be transcribed or copied without Sanken’s prior written consent. ● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples and evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of use of the Sanken Products and Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you, users or any third party, or any possible infringement of any and all property rights including intellectual property rights and any other rights of you, users or any third party, resulting from the foregoing. ● All technical information described in this document (the “Technical Information”) is presented for the sole purpose of reference of use of the Sanken Products and no license, express, implied or otherwise, is granted hereby under any intellectual property rights or any other rights of Sanken. ● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied, as to the quality of the Sanken Products (including the merchantability, or fitness for a particular purpose or a special environment thereof), and any information contained in this document (including its accuracy, usefulness, or reliability). ● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and regulations that regulate the inclusion or use of any particular controlled substances, including, but not limited to, the EU RoHS Directive, so as to be in strict compliance with such applicable laws and regulations. ● You must not use the Sanken Products or the Technical Information for the purpose of any military applications or use, including but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Technical Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan, and follow the procedures required by such applicable laws and regulations. ● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including the falling thereof, out of Sanken’s distribution network. ● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting from any possible errors or omissions in connection with the contents included herein. ● Please refer to the relevant specification documents in relation to particular precautions when using the Sanken Products, and refer to our official website in relation to general instructions and directions for using the Sanken Products. DJR0417 - DSE Rev.1.1 SANKEN ELECTRIC CO.,LTD. Dec.17, 2015 http://www.sanken-ele.co.jp/en/ © SANKEN ELECTRIC CO.,LTD. 2015 9