djr0417 ds en

40 V, 17 A P-channel Trench Power MOSFET with
Reverse Battery Protection
DJR0417
Data Sheet
Description
DJR0417 is P-channel trench power MOSFET
designed for the load switch of automotive electronic
units requiring the reverse battery protection. Since
DJR0417 has a bidirectional diode between Drain and
Source, the reverse battery protection can be realized
with only one load switch.
Package
TO252
(4)
(1)
Gate
(2)(4) Drain
(3)
Source
Features
● V(BR)DSS ---------------------------- − 40 V (ID = − 100 μA)
● ID ------------------------------------------------------ − 17 A
● RDS(ON) ------ 75 mΩ max. (ID = − 8.5 A, VGS = − 10 V)
(1) (2) (3)
(3) (2) (1)
Not to Scale
●
●
●
●
Automotive Qualified
Load switch can configure by only one component
For reverse battery protection
Compliant with RoHS Directive
Equivalent circuit
S(3)
Typical Application
Main switch
Schottky diode
RG
G(1)
Gate
driver
Battery
100Ω(typ.)
Reverse battery
protection
Body diode
Sub-MOSFET
Microcomputer
Load
D(2)(4)
GND
Gate driver is not required
Application
DJR0417
Battery
Microcomputer
● Car battery
Load
GND
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
1
DJR0417
Absolute Maximum Ratings
● Unless otherwise specified, TA = 25 °C
Parameter
Symbol
Test conditions
Rating
Unit
Drain to Source Voltage
VDS
− 40
V
Source to Drain Voltage
VSD
− 16
V
Gate to Source Voltage
VGS
− 15,+ 0
V
TC = 25 °C
− 17
A
230
mJ
48
W
Continuous Drain Current
ID
Single Pulse Avalanche Energy
EAS
VDD = − 15 V, L = 1 mH,
IAS = − 17 A, unclamped,
Refer to Figure 1
Power Dissipation
PD
TC = 25 °C
Operating Junction Temperature
TJ
− 55 to 150
°C
Storage Temperature Range
TSTG
− 55 to 150
°C
Maximum Drain to Source dv/dt
dv/dt
0.075
V/ns
Thermal Characteristics
● Unless otherwise specified, TA = 25 °C
Parameter
Thermal Resistance
(Junction to Case)
Symbol
Test Conditions
RθJC
Min.
Typ.
Max.
Unit
−
−
2.6
°C/W
Min.
Typ.
Max.
Unit
Electrical Characteristic
● Unless otherwise specified, TA = 25 °C
Parameter
Drain to Source Breakdown
Voltage
Drain to Source Leakage Current
Symbol
V(BR)DSS
ID = − 100 μA, VGS = 0 V
− 40
−
−
V
IDSS
VDS = − 40 V, VGS = 0 V
−
−
− 100
µA
Gate to Source Leakage Current
IGSS
VGS = − 15 V
−
−
− 100
µA
VDS = − 10 V, ID = − 1 mA
− 1.0
− 1.75
− 2.5
V
ID = − 8.5 A, VGS = − 10 V
−
50
75
mΩ
ID = − 5 A, VGS = − 4.5 V
−
130
350
mΩ
−
75
−
−
9
−
−
30
−
−
90
−
−
450
−
−
990
−
tf
VDD = − 15 V
ID = − 8.5 A
RG = 10 Ω, RL = 1.53 Ω,
RGS = 50 Ω
VGS = − 10 V
Refer to Figure 2
−
910
−
V(BR) SD
IS = − 1m A, VGS = 0 V
− 16
−
−
Gate Threshold Voltage
VGS(th)
Static Drain to Source
On-Resistance
RDS(ON)
Total Gate Charge (VGS = 10 V)
Qg
Gate to Source Charge
Qgs
Gate to Drain Charge
Qgd
Turn-On Delay Time
td(on)
Rise Time
Turn-Off Delay Time
Fall Time
Source to Drain Breakdown
Voltage
tr
td(off)
Test Conditions
VDS = -15 V
ID = − 8.5 A
VGS = − 10 V
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
nC
ns
V
2
DJR0417
Test Circuits and Waveforms
E AS 
V(BR)DSS
1
2
 L  I AS 
2
V(BR)DSS  VDD
VDS
0
L
VDD
ID
VDS
V(BR)DSS
S
0V
VDD
G
RG
ID
0
D
VGS
IAS
(a) Test Circuit
(b) Waveform
Figure 1 Unclamped Inductive Switching
VGS
0
10%
RL
90%
VDS
RG
G
VDD
0V
RGS
VDS
S
0
90%
D
VGS
10%
td(on) tr
P.W. = 10 μs
Duty cycle ≤ 1 %
td(off) tf
ton
(a) Test Circuit
toff
(b) Waveform
Figure 2 Switching Time
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
3
DJR0417
Performance Curves
ID-VGS characteristics (typical)
ID-VDS characteristics(typical)
Tc=25°C
- 20
-10V
VDS= -10V
- 20
-6V
-5V
- 15
- 15
ID (A)
- 10
ID (A)
Tc = -55℃
VGS = -4.5V
-5
25℃
85℃
- 10
150℃
-5
0
0
-2
-1
-3
-4
0
-5
-1
0
-4
-3
-2
-5
-6
-7
VGS (V)
VDS (V)
VDS - VGS characteristics (typical)
Vth - TC characteristics (typical)
VDS= -10V
ID= -1mA
- 2.5
-10
-8
-6
Vth(V)
VDS (V)
- 2.0
- 1.5
-4
ID= -17A
- 1.0
ID= -10A
-2
ID= -5A
0
0
-5
- 10
- 15
- 0.5
-100
VGS (V)
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
-50
0
50
100
150
200
Tc (°C)
4
DJR0417
RDS(ON)-TC characteristics (typical)
VGS-Qg characteristics (typical)
ID= -8.5A
VGS= -10V
100
Tc=25°C
- 10
80
-8
60
-6
VGS (V)
RDS (ON) (mΩ)
ID= -8.5A
VDD= -15V
40
-4
-2
20
0
-100
0
-50
0
50
100
150
200
0
20
40
Tc (°C)
60
80
Qg (nC)
V(BR)SD - TC characteristics (typical)
V(BR)DSS - TC characteristics (typical)
ID= -5mA
- 24
ID= -1mA
- 60
- 23
- 50
- 21
V(BR)DSS (V)
V(BR)SD (V)
- 22
- 20
- 19
- 18
- 40
- 30
- 17
- 16
-100
- 20
-50
0
50
100
150
200
-100
Tc (°C)
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
-50
0
50
100
150
200
Tc (°C)
5
DJR0417
ID-TC characteristics
EAS-Tc characteristics
- 20
250
- 15
150
ID (A)
EAS (mJ)
200
- 10
100
-5
50
0
0
25
50
75
100
125
0
150
25
50
75
100
125
150
Tc (°C)
Tc (°C)
SAFE OPARATING AREA
PD-Ta Derating
Tc=25°C
Single Pulse
- 100
60
With infinite heatsink
50
PT=100us
- 10
PT=1ms
ID (A)
PD (W)
40
30
PT=10ms
-1
20
RDS(on) LIMITED
10
0
0
25
50
75
100
125
150
- 0.1
- 0.1
Ta (°C)
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
-1
- 10
- 100
VDS (V)
6
DJR0417
Tc=25°C
Single Pulse
TRANSIENT THERMAL RESISTANCE - PULSE WIDTH
10
Rth (j-c) (°C//W)
1
0.1
0.01
0.00001
0.0001
0.001
0.01
0.1
1
10
P.T. (sec)
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
7
DJR0417
External Dimensions
● TO252
NOTES:
● Dimension is in millimeters
● Pb-free. Device composition compliant with the RoHS directive
Marking Diagram
DJR0417
Part Number
SK
YM
DD
Lot Number
Y is the Last digit of the year (0 to 9)
M is the Month (1 to 9, O, N or D)
DD is the Date (two digit of 01 to 31)
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
8
DJR0417
IMPORTANT NOTES
● All data, illustrations, graphs, tables and any other information included in this document as to Sanken’s products listed herein (the
“Sanken Products”) are current as of the date this document is issued. All contents in this document are subject to any change
without notice due to improvement, etc. Please make sure that the contents set forth in this document reflect the latest revisions
before use.
● The Sanken Products are intended for use as components of electronic equipment or apparatus (transportation equipment and its
control systems, home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Prior to use of the
Sanken Products, please put your signature, or affix your name and seal, on the specification documents of the Sanken Products
and return them to Sanken. If considering use of the Sanken Products for any applications that require higher reliability (traffic
signal control systems or equipment, disaster/crime alarm systems, etc.), you must contact a Sanken sales representative to discuss
the suitability of such use and put your signature, or affix your name and seal, on the specification documents of the Sanken
Products and return them to Sanken, prior to the use of the Sanken Products. Any use of the Sanken Products without the prior
written consent of Sanken in any applications where extremely high reliability is required (aerospace equipment, nuclear power
control systems, life support systems, etc.) is strictly prohibited.
● In the event of using the Sanken Products by either (i) combining other products or materials therewith or (ii) physically,
chemically or otherwise processing or treating the same, you must duly consider all possible risks that may result from all such
uses in advance and proceed therewith at your own responsibility.
● Although Sanken is making efforts to enhance the quality and reliability of its products, it is impossible to completely avoid the
occurrence of any failure or defect in semiconductor products at a certain rate. You must take, at your own responsibility,
preventative measures including using a sufficient safety design and confirming safety of any equipment or systems in/for which
the Sanken Products are used, upon due consideration of a failure occurrence rate or derating, etc., in order not to cause any human
injury or death, fire accident or social harm which may result from any failure or malfunction of the Sanken Products. Please refer
to the relevant specification documents and Sanken’s official website in relation to derating.
● No anti-radioactive ray design has been adopted for the Sanken Products.
● No contents in this document can be transcribed or copied without Sanken’s prior written consent.
● The circuit constant, operation examples, circuit examples, pattern layout examples, design examples, recommended examples and
evaluation results based thereon, etc., described in this document are presented for the sole purpose of reference of use of the
Sanken Products and Sanken assumes no responsibility whatsoever for any and all damages and losses that may be suffered by you,
users or any third party, or any possible infringement of any and all property rights including intellectual property rights and any
other rights of you, users or any third party, resulting from the foregoing.
● All technical information described in this document (the “Technical Information”) is presented for the sole purpose of reference
of use of the Sanken Products and no license, express, implied or otherwise, is granted hereby under any intellectual property
rights or any other rights of Sanken.
● Unless otherwise agreed in writing between Sanken and you, Sanken makes no warranty of any kind, whether express or implied,
as to the quality of the Sanken Products (including the merchantability, or fitness for a particular purpose or a special environment
thereof), and any information contained in this document (including its accuracy, usefulness, or reliability).
● In the event of using the Sanken Products, you must use the same after carefully examining all applicable environmental laws and
regulations that regulate the inclusion or use of any particular controlled substances, including, but not limited to, the EU RoHS
Directive, so as to be in strict compliance with such applicable laws and regulations.
● You must not use the Sanken Products or the Technical Information for the purpose of any military applications or use, including
but not limited to the development of weapons of mass destruction. In the event of exporting the Sanken Products or the Technical
Information, or providing them for non-residents, you must comply with all applicable export control laws and regulations in each
country including the U.S. Export Administration Regulations (EAR) and the Foreign Exchange and Foreign Trade Act of Japan,
and follow the procedures required by such applicable laws and regulations.
● Sanken assumes no responsibility for any troubles, which may occur during the transportation of the Sanken Products including
the falling thereof, out of Sanken’s distribution network.
● Although Sanken has prepared this document with its due care to pursue the accuracy thereof, Sanken does not warrant that it is
error free and Sanken assumes no liability whatsoever for any and all damages and losses which may be suffered by you resulting
from any possible errors or omissions in connection with the contents included herein.
● Please refer to the relevant specification documents in relation to particular precautions when using the Sanken Products, and refer
to our official website in relation to general instructions and directions for using the Sanken Products.
DJR0417 - DSE Rev.1.1
SANKEN ELECTRIC CO.,LTD.
Dec.17, 2015
http://www.sanken-ele.co.jp/en/
© SANKEN ELECTRIC CO.,LTD. 2015
9