CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date Issued to: This is to certify that representative samples of 20141229-E135493 E135493-A27-UL 2014-DECEMBER-29 VICOR CORP 25 FRONTAGE RD ANDOVER MA 01810 POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT AC/DC Converter- VIA PFM series Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07Information Technology Equipment - Safety - Part 1: General Requirements See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Certification Mark on the product. Bruce Mahrenholz, Assistant Chief Engineer, Global Inspection and Field Services UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 1 Issue Date: 2014-12-22 Page 1 of 5 Report Reference # E135493-A27-UL 2015-11-04 UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: General Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) Product: Model: AC/DC Converter VIA PFM series Rating: See Miscellaneous Enclosure for model details. Rated Input Voltage: 85-264 Vac(rectified) Rated Output Voltage: 24 Vdc Rated Output Power: 400W max See Miscellaneous Enclosure for model details. Applicant Name and Address: VICOR CORP 25 FRONTAGE RD ANDOVER MA 01810-5424 UNITED STATES This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Hong Ung Reviewed by: Dean Baker Copyright © 2015 Issue Date: 2014-12-22 Page 2 of 5 Report Reference # E135493-A27-UL 2015-11-04 Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. Product Description The VIA PFM Series are a family of isolating AC-DC converters that are designed for building-in. The output is considered SELV. Model Differences See Miscellaneous Enclosure for model nomenclature Technical Considerations Equipment mobility : for building-in Connection to the mains : not directly connected to the mains Operating condition : continuous Access location : for building-in Over voltage category (OVC) : OVC II Mains supply tolerance (%) or absolute mains supply values : 85-264 Vac (rectified) Tested for IT power systems : - IT testing, phase-phase voltage (V) : N/A Class of equipment : Class I (earthed) Considered current rating of protective device as part of the building installation (A) : N/A Pollution degree (PD) : PD 2 IP protection class : IP X0 Altitude of operation (m) : Up to 5000 Altitude of test laboratory (m) : less than 2000 meters Mass of equipment (kg) : 0.157 Issue Date: 2014-12-22 Page 3 of 5 Report Reference # E135493-A27-UL 2015-11-04 Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The following secondary output circuits are SELV: All. The following secondary output circuits are at hazardous energy levels: All. The investigated Pollution Degree is: 2 The following end-product enclosures are required: Mechanical, Fire, Electrical. An external bridge rectifier is required in front of the PFM. The output is separated from the input by reinforced insulation. The VIA PFM was evaluated over the full operating range of 85-264Vac rectified. See de-rating curve for maximum output power vs. case temperature in Miscellaneous Enclosure. The case must be earthed in the end application. The VIA PFM was evaluated with fast acting external fuse rated 8A (Littelfuse 216 series or Bussmann S501). Additional Information N/A Issue Date: 2014-12-22 Page 4 of 5 2015-11-04 VIA PFM Model Number: PFMaabbcddewwxxyzz Example: PFM4914VB6M24D0T00 PFM = Constant Product Function PFM Power Factor Module aa = 49 Package Length Designator 44 4.4 inches 49 4.9 inches bb = 14 Package Width Designator 14 1.4 inches c=V Package Type V Chassis mount B Board mount dd = B6 Input Voltage range B6 85-264 Vac e=M Range Ratio (Vin high / Vin low) M 3.1 ww = 24 Output Voltage 24 24 Vdc 48 48 Vdc xx = D0 Output Power B0 200W D0 400W y= T Product Grade C -20 to 100°C T -40 to 100°C M -55 to 100°C zz = 00 Options (non-safety related) 00 Any alphanumeric Report Reference # E135493-A27-UL Issue Date: 2014-12-22 Page 5 of 5 Report Reference # E135493-A27-UL 2015-11-04 Customer Special Model Number PFA175B240C400A33 PFA175B240T400A33 PFA175B480C400A33 PFA175B480T400A33 PFA175C240C400A33 PFA175C240T400A33 PFA175C480C400A33 PFA175C480T400A33 PFA175G240C400A33 PFA175G240T400A33 PFA175G480C400A33 PFA175G480T400A33 Equivalent Standard Model Number PFM4914VB6M24D0C00 PFM4914VB6M24D0T00 PFM4914VB6M48D0C00 PFM4914VB6M48D0T00 PFM4914BB6M24D0C04 PFM4914BB6M24D0T04 PFM4914BB6M48D0C04 PFM4914BB6M48D0T04 PFM4914BB6M24D0C08 PFM4914BB6M24D0T08 PFM4914BB6M48D0C08 PFM4914BB6M48D0T08 Output Power vs. Case Temperature for operation from 85-264 Vac (rectified).