PDF cURus UL 60950-1, CSA 60950-1

CERTIFICATE OF COMPLIANCE
Certificate Number
Report Reference
Issue Date
Issued to:
This is to certify that
representative samples of
20150720-E135493
E135493-A30-UL
2015-July-20
VICOR CORP
25 FRONTAGE RD
ANDOVER MA 01810
COMPONENT - POWER SUPPLIES,
INFORMATION TECHNOLOGY EQUIPMENT
INCLUDING ELECTRICAL BUSINESS
EQUIPMENT
DC-DC Converter- Low Voltage Panel Mold 6123 BCM and
NBM Series
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety:
Additional Information:
UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07Information Technology Equipment - Safety - Part 1:
General Requirements.
See the UL Online Certifications Directory at
www.ul.com/database for additional information
Only those products bearing the UL Certification Mark should be considered as being covered by UL's
Certification and Follow-Up Service.
Recognized components are incomplete in certain constructional features or restricted in performance
capabilities and are intended for use as components of complete equipment submitted for investigation rather
than for direct separate installation in the field. The final acceptance of the component is dependent upon its
installation and use in complete equipment submitted to UL LLC.
Look for the UL Certification Mark on the product.
Bruce Mahrenholz, Assistant Chief Engineer, Global Inspection and Field Services
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at www.ul.com/contactus
Page 1 of 1
Issue Date:
2015-07-16
Page 1 of 7
Report Reference #
E135493-A30-UL
2015-09-14
UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
Product:
Model:
UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Component Recognition
QQGQ2, QQGQ8 (Power Supplies for Information Technology
Equipment Including Electrical Business Equipment)
DC-DC Converter
Low Voltage Panel Mold 6123 BCM and NBM Series
See Miscellaneous Enclosure for model details.
Rated Input Voltage: 60 Vdc Max
Rated Output Voltage: 15 Vdc max
Rated Output Current: 180 A max
See Miscellaneous Enclosure for model ratings.
Rating:
Applicant Name and Address:
VICOR CORP
25 FRONTAGE RD
ANDOVER MA 01810-5424
UNITED STATES
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up
Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific
Technical Criteria through to the end of the Conditions of Acceptability.
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.
Prepared by:
Hong Ung
Reviewed by: Lesley Green
Copyright © 2015
Issue Date:
2015-07-16
Page 2 of 7
Report Reference #
E135493-A30-UL
2015-09-14
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
The Voltage Panel Mold 6123 BCMs and NBMs are a family of DC-DC converters that are designed for
building-in. The output voltage is an unregulated fixed turns ratio of the input voltage. The BCMs provide
insulation from input to output. The NBMs are non-isolating devices.
Model Differences
See Miscellaneous Enclosure for model nomenclature.
Technical Considerations

Equipment mobility : for building-in

Connection to the mains : not directly connected to the mains

Operating condition : continuous

Access location : for building-in

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : 36-60 Vdc

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : N/A

Class of equipment : Not classified

Considered current rating of protective device as part of the building installation (A) : N/A

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : Up to 5000 meters

Altitude of test laboratory (m) : less than 2000 meters

Mass of equipment (kg) : 0.042
Issue Date:
2015-07-16
Page 3 of 7
Report Reference #
E135493-A30-UL
2015-09-14
Engineering Conditions of Acceptability
For use only in or with complete equipment where the acceptability of the combination is determined by UL
LLC. When installed in an end-product, consideration must be given to the following:

The investigated Pollution Degree is: 2

The following end-product enclosures are required: Mechanical, Fire, Electrical

The output of the BCM is separated from the input by Basic insulation and is considered SELV.

The output of the non-isolating NBM can be considered SELV if the input is SELV.

The BCM was evaluated with a Littelfuse 456 series fuse rated 40A max.

The NBM was evaluated without a fuse.

The output has not been evaluated for energy hazards.

See de-rating curves for maximum output current versus case temperature.
Additional Information
N/A
Issue Date:
2015-07-16
Page 4 of 7
Report Reference #
E135493-A30-UL
2015-09-14
VICHIP Low Voltage Panel Mold 6123 BCM Model Matrix: aaa6123bccdwwxxyzz
Example: BCM6123T60F15A3T00
aaa = BCM
Product Function
BCM Isolated Bus Converter Module
NBM Non-isolated Bus Converter Module
6123 = Constant
Package Size (Length x Width)
6123 61 mm x 23 mm
b= T
Lead Designator
T
Through-Hole
S
Surface Mount
L
Leadless
cc = 60
Maximum Input Voltage (range)
46
46 Vdc (36-46)
60
60 Vdc (36-60)
d= F
Range Ratio (Vin high / Vin low)
C
1.3
E
1.6
F
1.7
ww = 15
Maximum Output Voltage
10
10 Vdc
12
12 Vdc
15
15 Vdc
xx = A3
Maximum Output Current
A3
130A
65
A5
150A
75
A6
160A
80
A7
170A
85
A8
180A
90
65A
75A
80A
85A
90A
y= T
Product Grade
C
-20 to 100°C
T
-40 to 100°C
M
-55 to 100°C
zz = 00
Options (non-safety related)
00
Any alphanumeric
Issue Date:
2015-07-16
Page 5 of 7
Report Reference #
2015-09-14
Customer Special Model Number
BCM54Aw135x1K8Ayz
BCM54Aw090x1K4Ayz
NBM42Aw140x2K2Ayz
NBM54Aw108x1K8Ayz
NBM54Aw108x1K9Ayz
Equivalent Standard Part Number
BCM6123b60F15A3yzz
BCM6123b60F10A5yzz
NBM6123b46C15A6yzz
NBM6123b60F12A7yzz
NBM6123b60F12A8yzz
w = Lead Designator (P, Q, or N)
P = Through hole
Q = Surface Mount
N = Leadless
b = Lead Designator (T, S, or L)
T = Through hole
S = Surface Mount
L = Leadless
x = Grade (T or M)
y = Package Size (C = 2361, 3 = 6123)
z = Communication Type (0, 1, or R)
y = Grade (C, T, or M)
zz = options (alphanumeric)
E135493-A30-UL
Issue Date:
2015-07-16
Page 6 of 7
Report Reference #
E135493-A30-UL
2015-09-14
Maximum current = xx in product part number, see model matrix for actual value.
Maximum current = xx in product part number, see model matrix for actual value.
Issue Date:
2015-07-16
Page 7 of 7
Report Reference #
E135493-A30-UL
2015-09-14
Maximum current = xx in product part number, see model matrix for actual value.
Maximum current = xx in product part number, see model matrix for actual value.