CERTIFICATE OF COMPLIANCE Certificate Number Report Reference Issue Date Issued to: This is to certify that representative samples of 20150720-E135493 E135493-A30-UL 2015-July-20 VICOR CORP 25 FRONTAGE RD ANDOVER MA 01810 COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT DC-DC Converter- Low Voltage Panel Mold 6123 BCM and NBM Series Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: UL 60950-1 and CAN/CSA C22.2 No. 60950-1-07Information Technology Equipment - Safety - Part 1: General Requirements. See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Recognized components are incomplete in certain constructional features or restricted in performance capabilities and are intended for use as components of complete equipment submitted for investigation rather than for direct separate installation in the field. The final acceptance of the component is dependent upon its installation and use in complete equipment submitted to UL LLC. Look for the UL Certification Mark on the product. Bruce Mahrenholz, Assistant Chief Engineer, Global Inspection and Field Services UL LLC Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please contact a local UL Customer Service Representative at www.ul.com/contactus Page 1 of 1 Issue Date: 2015-07-16 Page 1 of 7 Report Reference # E135493-A30-UL 2015-09-14 UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology Equipment - Safety - Part 1: General Requirements) CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information Technology Equipment - Safety - Part 1: General Requirements) Component Recognition QQGQ2, QQGQ8 (Power Supplies for Information Technology Equipment Including Electrical Business Equipment) DC-DC Converter Low Voltage Panel Mold 6123 BCM and NBM Series See Miscellaneous Enclosure for model details. Rated Input Voltage: 60 Vdc Max Rated Output Voltage: 15 Vdc max Rated Output Current: 180 A max See Miscellaneous Enclosure for model ratings. Rating: Applicant Name and Address: VICOR CORP 25 FRONTAGE RD ANDOVER MA 01810-5424 UNITED STATES This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: Hong Ung Reviewed by: Lesley Green Copyright © 2015 Issue Date: 2015-07-16 Page 2 of 7 Report Reference # E135493-A30-UL 2015-09-14 Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. Product Description The Voltage Panel Mold 6123 BCMs and NBMs are a family of DC-DC converters that are designed for building-in. The output voltage is an unregulated fixed turns ratio of the input voltage. The BCMs provide insulation from input to output. The NBMs are non-isolating devices. Model Differences See Miscellaneous Enclosure for model nomenclature. Technical Considerations Equipment mobility : for building-in Connection to the mains : not directly connected to the mains Operating condition : continuous Access location : for building-in Over voltage category (OVC) : OVC II Mains supply tolerance (%) or absolute mains supply values : 36-60 Vdc Tested for IT power systems : No IT testing, phase-phase voltage (V) : N/A Class of equipment : Not classified Considered current rating of protective device as part of the building installation (A) : N/A Pollution degree (PD) : PD 2 IP protection class : IP X0 Altitude of operation (m) : Up to 5000 meters Altitude of test laboratory (m) : less than 2000 meters Mass of equipment (kg) : 0.042 Issue Date: 2015-07-16 Page 3 of 7 Report Reference # E135493-A30-UL 2015-09-14 Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: The investigated Pollution Degree is: 2 The following end-product enclosures are required: Mechanical, Fire, Electrical The output of the BCM is separated from the input by Basic insulation and is considered SELV. The output of the non-isolating NBM can be considered SELV if the input is SELV. The BCM was evaluated with a Littelfuse 456 series fuse rated 40A max. The NBM was evaluated without a fuse. The output has not been evaluated for energy hazards. See de-rating curves for maximum output current versus case temperature. Additional Information N/A Issue Date: 2015-07-16 Page 4 of 7 Report Reference # E135493-A30-UL 2015-09-14 VICHIP Low Voltage Panel Mold 6123 BCM Model Matrix: aaa6123bccdwwxxyzz Example: BCM6123T60F15A3T00 aaa = BCM Product Function BCM Isolated Bus Converter Module NBM Non-isolated Bus Converter Module 6123 = Constant Package Size (Length x Width) 6123 61 mm x 23 mm b= T Lead Designator T Through-Hole S Surface Mount L Leadless cc = 60 Maximum Input Voltage (range) 46 46 Vdc (36-46) 60 60 Vdc (36-60) d= F Range Ratio (Vin high / Vin low) C 1.3 E 1.6 F 1.7 ww = 15 Maximum Output Voltage 10 10 Vdc 12 12 Vdc 15 15 Vdc xx = A3 Maximum Output Current A3 130A 65 A5 150A 75 A6 160A 80 A7 170A 85 A8 180A 90 65A 75A 80A 85A 90A y= T Product Grade C -20 to 100°C T -40 to 100°C M -55 to 100°C zz = 00 Options (non-safety related) 00 Any alphanumeric Issue Date: 2015-07-16 Page 5 of 7 Report Reference # 2015-09-14 Customer Special Model Number BCM54Aw135x1K8Ayz BCM54Aw090x1K4Ayz NBM42Aw140x2K2Ayz NBM54Aw108x1K8Ayz NBM54Aw108x1K9Ayz Equivalent Standard Part Number BCM6123b60F15A3yzz BCM6123b60F10A5yzz NBM6123b46C15A6yzz NBM6123b60F12A7yzz NBM6123b60F12A8yzz w = Lead Designator (P, Q, or N) P = Through hole Q = Surface Mount N = Leadless b = Lead Designator (T, S, or L) T = Through hole S = Surface Mount L = Leadless x = Grade (T or M) y = Package Size (C = 2361, 3 = 6123) z = Communication Type (0, 1, or R) y = Grade (C, T, or M) zz = options (alphanumeric) E135493-A30-UL Issue Date: 2015-07-16 Page 6 of 7 Report Reference # E135493-A30-UL 2015-09-14 Maximum current = xx in product part number, see model matrix for actual value. Maximum current = xx in product part number, see model matrix for actual value. Issue Date: 2015-07-16 Page 7 of 7 Report Reference # E135493-A30-UL 2015-09-14 Maximum current = xx in product part number, see model matrix for actual value. Maximum current = xx in product part number, see model matrix for actual value.