AXIOM37-8LG

Specification
Oscillator type:
Rev.: 1
Date: 2016-02-29
AXIOM37-8LG
Ultra-Low Power Miniature OCXO with HCMOS Output
Low G-sensitivity and high mechanical robustness
Produced in association with Magic Xtal – Model MXO37/8D
Parameter
Frequency range
Standard frequencies
Frequency stability
Initial tolerance @ +25°C
vs. operating temperature range
vs. supply voltage variation (pushing)
vs. load change (pulling)
Long term (aging) per day,
after 30 days operation (Note 2)
st
Long term (aging) 1 year,
after 30 days operation (Note 2)
Frequency adjustment range
Electronic Frequency Control (EFC)
EFC voltage VC
EFC slope (∆f / ∆VC)
RF output
Signal waveform
Load
Symmetry (duty cycle)
Rise & decay time
Warm-up time @ +25°C
∆ffinal/f0 < ±0.1 ppm (Note 3)
Phase noise @ 10.000 MHz
min.
8
typ.
max.
100
10.000 / 100.000
±100
Option 2 & 3
See tables 1 & 2
±2
±2
±0.5
0
MHz
MHz
steady state
±2
±5
±200
±500
ppb
ppb
ppb
Ppb
ppb
ppb
VREF
ppm
V
±1.0
VS ±5%
Load ±10 %
< 50 MHz
≥ 50 MHz
< 50 MHz
≥ 50 MHz
Positive
HCMOS
10
45
55
10
Power consumption (steady state)
Power consumption (warm-up)
Enclosure (see drawing) (LxWxH)
Weight
Packing
15.1x15.1x10.5 max.
10
Palette
G-sensitivity
Reference voltage VREF output
Notes:
1.
2.
3.
Condition
ppb
70
60
-97
-127
-152
-162
-166
0.5
2.8
4.2
3.3
5.0
0.23
1.0
Supply voltage VS
Unit
3.15
4.75
1.0
3.45
5.25
pF
%
ns
sec
sec
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
ppb/g
V
V
V
V
W
W
±10%
@ VS/2
@ 10% ~ 90% VS
Option 1 = “33”
Option 1 = “50”
@ 1 Hz
@ 10 Hz
@ 100 Hz
@ 1 kHz
@ 10 kHz
Worst axis
Option 1 = “33”
Option 1 = “50”
Option 1 = “33”
Option 1 = “50”
@ +25°C
mm
g
Terminology and test conditions are according to IEC60679-1 and MIL-PRF-55310, unless otherwise state
Lower aging rates on request
Typical values for 10 MHz. Frequency referred to ffinal at 15 minutes after switch-on
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
AXIOM37-8LG Rev.1
Drawing D2
Page 1(4)
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Absolute Maximum Ratings
Parameter
min.
max.
Supply Voltage VS
Control Voltage VC
Storage Temperature
-0.5
-0.5
-60
VS + 10%
10
+90
Unit
Condition
V
V
°C
VS to GND
VC to GND
Frequency stability vs. Temperature
Stability
[ppb]
±5
±10
±20
±30
±50
±100
Option 2
05
10
20
30
50
100
Table 1
Lower Temperature
Option 3
T [°C]
0
0
1
-10
2
-20
3
-30
4
-40
Table 2
Upper Temperature
Option 3
T [°C]
A
+50
B
+60
C
+70
D
+75
E
+80
F
+85
Standard: “1B” = -10°C to +60°C
Note: Not all combinations of stability and temperature range may be available. Please consult factory.
Ordering Code
Option 1
Option 2
Option 3
[Supply Voltage]
[Stability]
[Temperature range]
AXIOM37-8LG
33 or 50
Table 1
Table 2
Example: AXIOM37-8LG-50-05-1B_Rev.1 – 10.000 MHz
Model
Handling and Testing
Parameter
Handling and Testing
Processing
Solderability
Parameter
Electrostatic discharge (ESD)
THD devices
SMD devices
Washable
RoHS- Compliant
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Revision
Frequency [MHz]
Rev.1
10.000
Procedure
Application Note AXAN-011
Application Note AXAN-012
Hand soldering required.
Reflow soldering not allowed !
Procedure
IEC60749-26
IEC60749-27
Yes
Yes
AXIOM37-8LG Rev.1
Drawing D2
Page 2(4)
HBM
MM
No
No
Source
www.axtal.com
www.axtal.com
Condition
2000 V
200 V
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Enclosure drawing
Pin connections:
Pin #
1
2
4
5
8
Symbol
VC
VREF
GND
RF OUT
VS
Function
Control Voltage (EFC)
Reference voltage
Ground
RF Output
Supply Voltage
* See Application Note AXAN-011
Environmental conditions
Test
Sealing tests
(if applicable)
Solderability
Resistance to
soldering heat
Shock*
Vibration,
sinusoidal*
Vibration,
random*
Humidity
Endurance tests
- ageing
- extended aging
IEC
60068
Part …
2-17
IEC
60679-1
Clause
5.6.2
MIL-STD202G
Method
112E
2-20
5.6.3
208H
2-27
5.6.8
213B
516.4
3.6.40
2-6
5.6.7.1
516.4-4
2-64
5.6.7.3
201A
204D
214A
3.6.38.1
3.6.38.2
3.6.38.3
3.6.38.4
-
103B
108A
5.7.1
5.7.2
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
MIL-STD810F
Method
MIL-PRF55310E
Clause
3.6.1.2
3.6.52
514.5
4.8.35
AXIOM37-8LG Rev.1
Drawing D2
Page 3(4)
Test conditions (IEC)
Gross leak: Test Qc,
Fine leak: Test Qk
Test Ta Method 1
Test Ea, 3 x per axes 500g,
1 ms half-sine pulse
Test Fc, 30 min per axes,
10 Hz - 55 Hz 1.5mm; 55 Hz - 2 kHz, 30g
Test Fdb
Non-condensing @ 95% RH, cond. B
30 days @ 85°C, OCXO @25°C
1000h, 2000h, 8000h @85°C
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]
Revision History
Rev.
Drawing
Date
[dd.mm.yyyy]
1
1
1
D0
D1
D2
22.04.2015
18.09.2015
29.02.2016
GmbH & Co. KG
Roemerring 9
D-74821 Mosbach
Germany
Remarks
First issue – Replacement of AXIOM37-8D
Editorial changes
Editorial changes
AXIOM37-8LG Rev.1
Drawing D2
Page 4(4)
Author
Checked
HH
HH
HH
HH
HH
HH
www.axtal.com
fon: +49 (6261) 939834
fax: +49 (6261) 939836
E-mail: [email protected]