DLA 05006

REVISIONS
LT
DESCRIPTION
Added “J” tolerance (±5%) to all BR and BX
capacitors. Added paragraphs 1.3 and 6.4. Revised
tables VI, VII, and VIII.
Revised the available voltages in table VII for
vendors A and C.
Changed address of vendor D.
Updated tables VII and VIII for vendor D.
Canceled PINs that have duplicates in MIL-PRF55681. Added K and M tolerance to BP capacitors.
Specified the life test sample size. Updated tables
VI, VII, and VIII.
Updated tables VII, and VIII for vendor C.
A
B
C
D
E
F
DATE
APPROVED
21 April 2008
Michael A. Radecki
22 January 2009
Michael A. Radecki
1 July 2010
9 November 2010
Michael A. Radecki
Michael A. Radecki
13 October 2011
Michael A. Radecki
23 March 2012
Michael A. Radecki
CURRENT DESIGN ACTIVITY CAGE CODE 037Z3
HAS CHANGED NAMES TO:
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
Prepared in accordance with ASME Y14.100
REV STATUS
OF PAGES
PMIC N/A
Source Control drawing
REV
F
F
F
F
F
F
F
F
F
F
PAGES
1
2
3
4
5
6
7
8
9
10
PREPARED BY
MICHAEL A. RADECKI
Original date of
drawing
CHECKED BY
DESIGN ACTIVITY
DEFENSE SUPPLY CENTER, COLUMBUS
COLUMBUS, OH
TITLE
CAPACITORS, FIXED, CERAMIC, CHIP, 0805
11 April 2005
MICHAEL A. RADECKI
APPROVED BY
KENDALL A. COTTONGIM
SIZE
A
REV
AMSC N/A
CODE IDENT. NO.
037Z3
DWG NO.
F
PAGE
05006
1
OF
10
5910-2012-E07
1. SCOPE
1.1 Scope. This drawing and MIL-PRF-55681 describe the requirements for ceramic, chip. This drawing offers capacitors with
higher capacitance values and lower voltages than those currently offered in MIL-PRF-55681/1 or MIL-PRF-55681/7.
1.2 Part or Identifying Number (PIN) The complete PIN is as follows:
05006-
BX
102
B
J
Z
-
Drawing
number
Dielectric
(see 1.2.1)
Capacitance
value
(see 1.2.2)
Voltage
(see 1.2.3)
Capacitance
tolerance
(see 1.2.4)
Termination
finish
(see 1.2.5)
Group C
testing option
(see 1.2.6)
1.2.1 Dielectric. The dielectric type is identified by the following 2 letters as defined in 3.3.1: BP, BR, BX.
1.2.2 Capacitance value. The nominal capacitance value, expressed in picofarads (pF) is identified by a three digit number; the first
two digits represent significant figures and the last digit specifies the number of zeros to follow. When the nominal value is less than 10
pF, the letter “R” is used to indicate the decimal point and the succeeding digit(s) of the group represent significant figure(s). 1R0
indicates 1.0 pF; R75 indicates .75 pF; and 0R5 indicates 0.5 pF. See tables VI, VII, and VIII for values.
1.2.3 Voltage. The rated voltage for continuous operation at +125°C is identified by a single letter as shown in table I.
TABLE I. Rated voltage.
Symbol
Rated voltage (volts, dc)
X
Y
Z
A
B
C
10
16
25
50
100
200
1.2.4 Capacitance tolerance. The capacitance tolerance is identified by a single letter in accordance with table II.
TABLE II. Capacitance tolerance.
Symbol
Capacitance tolerance (±)
Tolerance applicability
C
.25 pF
BP < 10 pF
D
.50 pF
BP < 10 pF
F
1 percent
BP ≥ 10 pF
G
2 percent
BP ≥ 10 pF
J
5 percent
BP ≥ 10 pF, BR, BX
K
10 percent
BP ≥ 10 pF, BR, BX
M
20 percent
BP ≥ 10 pF, BR, BX
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
2
1.2.5 Termination finish. Termination finish is identified by a single letter as shown in table III.
TABLE III. Termination finish.
Symbol
Termination finish
M
Palladium-silver
U
Base metallization-barrier metal-solder coated (tin/lead alloy, with a minimum of 4 percent lead). Solder
has a melting point of +200°C or less. Solder coat thickness is a minimum of 60 microinches.
Z
Base metallization-barrier metal-tinned (tin/lead alloy, with a minimum of 4 percent lead)
1.2.6 Group C testing option. To require MIL-PRF-55681 group C testing, use the appropriate letter from table IV. If group C testing
is not desired, leave this location blank. NOTE: Ordering group C options that contain a 2,000 hour life test may extend the processing
time by 90 days or more.
TABLE IV. Group C testing option.
Letter
C
L
M
H
N/A
Group C testing option
Full group C
2,000 hour life test only
1,000 hour life test only
Low voltage humidity only
No group C testing.
1.3 MIL-PRF-55681 vs. DSCC Drawing 05006. When available, MIL-PRF-55681/1 and MIL-PRF-55681/7 capacitors are preferred
over DSCC Drawing 05006 capacitors. The military specification requires failure rate level verification and provides additional quality
assurance provisions that are not required in this drawing. Refer to tables VI and VIII for MIL-PRF-55681/1 and MIL-PRF-55681/7
availability guidance.
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not
include documents cited in other sections of this specification or recommended for additional information or as examples. While every
effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified
requirements of documents in sections 3 and 4 of this specification, whether or not they are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this
document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or
contract (See 6.2).
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-PRF-55681
-
MIL-PRF-55681/1
-
MIL-PRF-55681/7
-
Capacitor, Chip, Multiple Layer, Fixed, Unencapsulated, Ceramic Dielectric, Established Reliability and
Non-Established Reliability, General Specification For.
Capacitors, Chip, Multiple Layer, Fixed, Ceramic Dielectric, Established Reliability and Non-Established
Reliability, Styles CDR01, CDR02, CDR03, and CDR04.
Capacitors, Chip, Multiple Layer, Fixed, Ceramic Dielectric, Established Reliability and Non-Established
Reliability, Style CDR31, Metric.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-202
MIL-STD-1285
-
Electronic and Electrical Components, Test Methods for.
Marking of Electrical and Electronic Parts.
(Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or from the Standardization Document
Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.)
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
3
L
W
T
Y
Dimensions
L
± .008
W
± .008
T
Max
Y
± .008
.080
.050
.055
.020
Inches
.008
.020
.050
.055
.080
mm
0.20
0.51
1.27
1.40
2.03
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Dimensions and tolerances are for bare chips. For solder coated terminations (symbol U), add .020 inch (0.51 mm) to the
positive length tolerance and .015 inch (0.38 mm) to the positive width and thickness tolerances.
FIGURE 1. Case dimensions and configuration.
2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this
document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes
applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-55681, and as specified herein.
Unless otherwise stated, these capacitors shall be capable of meeting all electrical, environmental, and mechanical requirements of
MIL-PRF-55681.
3.2 Interface and physical dimensions. The interface and physical dimensions shall be as specified in MIL-PRF-55681 and herein (see
figure 1).
3.2.1 Tin plated finishes. Tin plating is prohibited as a final finish or as an undercoat. Tin-lead (Sn-Pb) finishes are acceptable
provided that the minimum lead content is 4 percent (see 6.4).
3.3 Electrical characteristics.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
4
3.3.1 Dielectric type. The dielectric type shall be BP (±30 ppm/°C), BR (+15, -40 percent) or BX (+15, -25 percent) ceramic in
accordance with MIL-PRF-55681.
TABLE V. Voltage-temperature limits.
Symbol
Capacitance change with reference to +25°C
Step A through step D of
MIL-PRF-55681 table XIII
BP
0 ± 30 ppm/°C
Percent rated
voltage
100
Step E through step G of
MIL-PRF-55681 table XIII
BR
± 15 percent
100
0 ± 30 ppm/°C
+15, -40 percent
BX
± 15 percent
100
+15, -25 percent
3.3.2 Capacitance. Capacitance shall be in accordance with tables VI, VII, and VIII when measured in accordance with method 305 of
MIL-STD-202. The following conditions shall apply:
a. Test frequency: 1 MHz ±50kHz (for all BP characteristic capacitors ≤ 1,000 pF); or 1kHz ±50Hz for all other capacitors.
b. Test voltage: 1.0 volt ±0.2 volt rms.
3.3.3 Dissipation factor (+25°C). The dissipation factor shall not exceed 0.15 percent for BP characteristic capacitors, 5.0 percent for 10V
BR and BX characteristic capacitors, 3.5 percent for 16V and 25V BR and BX characteristic capacitors, and 2.5 percent for 50V to 200V BR
and BX characteristic capacitors.
3.3.4 Insulation resistance. At +25°C: minimum of 100,000 megohms or 1,000 megohm-microfarads, whichever is less.
At +125°C: minimum of 10,000 megohms or 100 megohm-microfarads, whichever is less for BR and BX
dielectrics; and minimum of 1,000 megohms or 10 megohm-microfarads, whichever is less for
BP dielectric.
3.4 Solderability. In accordance with MIL-PRF-55681, except the sample size shall be 5 pieces with zero defectives permitted.
3.5 Moisture resistance. In accordance with MIL-PRF-55681, with the following exceptions:
a. Polarizing voltage shall be rated voltage.
b. Testing may be performed on chips with a larger width and/or length as long as they are cut from the same wafer(s) as those used
for production.
3.6 Marking. As a minimum, marking shall be on the package due to the small size of the chips. The package marking shall be in
accordance with MIL-STD-1285, except the PIN shall be as specified in paragraph 1.2 with manufacturer’s name or CAGE code and date
code. The manufacturer may, at their option, mark some information on the chips.
3.7 Manufacturer eligibility. To be eligible for listing as an approved source of supply, a manufacturer shall be listed in the
MIL-PRF-55681 Qualified Products Database for at least one part, or perform the group A and group C inspections specified herein on
a sample of parts agreed upon by the manufacturer and DLA Land and Maritime-VAT.
3.8 Certificate of compliance. A certificate of compliance shall be required from manufacturers requesting to be an approved source of
supply.
3.9 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should
be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and
promotes economically advantageous life cycle costs.
3.10 Workmanship. In accordance with MIL-PRF-55681.
4. VERIFICATION
4.1 Qualification inspection. Qualification inspection is not required.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
5
4.2 Conformance inspection.
4.2.1 Inspection of product for delivery. Inspection of product for delivery shall consist of all tests specified in group A of MIL-PRF-55681.
ESR testing and PPM testing and calculation are not applicable. When optional group C testing is requested, terminal strength and series
resonance are not applicable. In addition, the life test sample shall be 25 with one defective permitted.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When
packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible
packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control Point’s
packaging activities within the Military Service or Defense Agency, or within the military service’s system commands. Packaging data
retrieval is available from the managing Military Department’s or Defense Agency’s automated packaging files, CD-ROM products, or
by contacting the responsible packaging activity.
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Intended use. Capacitors conforming to this drawing are intended for use when military specifications do not exist and qualified
military devices that will perform the required function are not available for OEM application. This drawing is intended exclusively to prevent
the proliferation of unnecessary duplicate specifications, drawings, and stock catalog listings. When a military specification exists and the
product covered by this drawing has been qualified for listing, this drawing becomes obsolete and will not be used for new design.
6.2 Ordering data. The contract or purchase order should specify the following:
a. Complete PIN (see 1.2).
b. Requirements for delivery of one copy of the conformance inspection data or certificate of compliance that parts have passed
conformance inspection with each shipment of parts by the manufacturer.
c. Requirements for notification of change of product to acquiring activity, if applicable.
d. Requirements for packaging and packing.
6.3 Replaceability. Capacitors covered by this drawing will replace the same commercial device covered by a contractor-prepared
specification or drawing.
6.4 Tin whisker growth. The use of alloys with tin content greater than 97 percent, by mass, may exhibit tin whisker growth problems
after manufacture. Tin whiskers may occur anytime from a day to years after manufacture and can develop under typical operating
conditions, on products that use such materials. Conformal coatings applied over top of a whisker-prone surface will not prevent the
formation of tin whiskers. Alloys of 3 percent lead, by mass, have shown to inhibit the growth of tin whiskers. For additional information
on this matter, refer to ASTM-B545 (Standard Specification for Electrodeposited Coatings of Tin).
6.5 Users of record. Coordination of this document for future revisions is coordinated only with the approved sources of supply and
the users of record of this document. Requests to be added as a recorded user of this drawing should be in writing to: DLA Land and
Maritime, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, by e-mail to [email protected], or by telephone (614)
692-4709 or DSN 850-4709.
6.6 Approved sources of supply. Approved sources of supply are listed herein. Additional sources will be added as they become
available. For assistance in the use of this drawing, contact DLA Land and Maritime, ATTN: VAT, Post Office Box 3990, Columbus,
OH 43218-3990, by e-mail to [email protected], or by telephone (614) 692-4709 or DSN 850-4709.
6.7 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from
the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any
inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the
entire content irrespective of the marginal notations and relationship to the last previous issue.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
6
TABLE VI. BP dielectric electrical characteristics.
DSCC
Drawing
05006- 1/
BP0R5- - - BP1R0- - - BP1R2- - - BP1R5- - - BP1R8- - - BP2R2- - - BP2R7- - - BP3R3- - - BP3R9- - - BP4R7- - - BP5R6- - - BP6R8- - - BP8R2- - - BP100- - - BP120- - - BP150- - - BP180- - - BP220- - - BP270- - - BP330- - - BP390- - - BP470- - - BP560- - - BP680- - - BP820- - - BP101- - - BP121- - - BP151- - - BP181- - - BP221- - - BP271- - - BP331- - - BP391- - - BP471- - - BP561- - - BP681- - - BP821- - - BP102- - - BP122- - - BP152- - - BP182- - - BP222- - - BP272- - - BP332- - - BP392- - - BP472- - - BP562- - - BP682- - - BP822- - - -
Capacitance
pF
.5
1.0
1.2
1.5
1.8
2.2
2.7
3.3
3.9
4.7
5.6
6.8
8.2
10
12
15
18
22
27
33
39
47
56
68
82
100
120
150
180
220
270
330
390
470
560
680
820
1,000
1,200
1,500
1,800
2,200
2,700
3,300
3,900
4,700
5,600
6,800
8,200
Available
tolerances
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
C, D
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
AVX
Vendor A
Available voltages
X Y Z A B C
10 16 25 50 100 200
● ● ● ● ●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ● 2/ ●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ●
● ●
2/
● ●
● ●
● ● ● ●
● ● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ●
● ●
KEMET 3/
Vendor B
Available voltages
PRESIDIO
Vendor C
Available voltages
VISHAY
Vendor D
Available voltages
X Y Z A B C X Y Z A B C X Y Z A B C
10 16 25 50 100 200 10 16 25 50 100 200 10 16 25 50 100 200
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ● 2/ ● ● ● ● ● 2/ ● ● ● ● ● 2/ ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
●
● ● ● ●
● ● ● ●
● ● ● ●
●
● ● ● ●
● ● ● ●
● ● ● ●
●
● ● ● ●
● ● ● ●
● ● ● ●
●
● ● ● ●
● ● ● ●
● ● ● ●
●
● ● ●
● ● ●
●
● ● ●
● ●
2/
2/
2/
● ● ●
● ● ●
● ● ●
● ●
● ● ● ●
● ● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ●
● ● ●
● ●
● ●
●
●
1/ Complete PIN shall include symbols to indicate voltage, capacitance tolerance, termination finish, and group C testing
option (see 1.2).
2/ Parts are canceled. Use MIL-PRF-55681/1 or MIL-PRF-55681/7 (see 1.3).
3/ Vendor does not supply termination finish “M”.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
7
TABLE VII. BR dielectric electrical characteristics.
DSCC
Drawing
05006- 1/
BR101- - - BR121- - - BR151- - - BR181- - - BR221- - - BR271- - - BR331- - - BR391- - - BR471- - - BR561- - - BR681- - - BR821- - - BR102- - - BR122- - - BR152- - - BR182- - - BR222- - - BR272- - - BR332- - - BR392- - - BR472- - - BR562- - - BR682- - - BR822- - - BR103- - - BR123- - - BR153- - - BR183- - - BR223- - - BR273- - - BR333- - - BR393- - - BR473- - - BR563- - - BR683- - - BR823- - - BR104- - - BR124- - - BR154- - - BR184- - - BR224- - - BR334- - - BR474- - - BR684- - - BR105- - - -
Capacitance
pF
100
120
150
180
220
270
330
390
470
560
680
820
1,000
1,200
1,500
1,800
2,200
2,700
3,300
3,900
4,700
5,600
6,800
8,200
10,000
12,000
15,000
18,000
22,000
27,000
33,000
39,000
47,000
56,000
68,000
82,000
100,000
120,000
150,000
180,000
220,000
330,000
470,000
680,000
1,000,000
Available
tolerances
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
AVX 2/
Vendor A
Available voltages
KEMET 3/
Vendor B
Available voltages
PRESIDIO
Vendor C
Available voltages
X Y Z A B C X Y Z A B C X Y Z A B C
10 16 25 50 100 200 10 16 25 50 100 200 10 16 25 50 100 200
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ●
● ● ● ●
● ● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ●
● ●
● ●
●
● ●
●
VISHAY
Vendor D
Available voltages
X Y Z A B C
10 16 25 50 100 200
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ●
● ● ●
● ●
● ●
1/ Complete PIN shall include symbols to indicate voltage, capacitance tolerance, termination finish, and group C testing
option (see 1.2).
2/ Vendor does not supply tolerance “J” (±5%).
3/ Vendor does not supply termination finish “M”.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
8
TABLE VIII. BX dielectric electrical characteristics.
DSCC
Drawing
05006- 1/
BX101- - - BX121- - - BX151- - - BX181- - - BX221- - - BX271- - - BX331- - - BX391- - - BX471- - - BX561- - - BX681- - - BX821- - - BX102- - - BX122- - - BX152- - - BX182- - - BX222- - - BX272- - - BX332- - - BX392- - - BX472- - - BX562- - - BX682- - - BX822- - - BX103- - - BX123- - - BX153- - - BX183- - - BX223- - - BX273- - - BX333- - - BX393- - - BX473- - - BX563- - - BX683- - - BX823- - - BX104- - - BX124- - - BX154- - - BX184- - - BX224- - - -
Capacitance
pF
Available
tolerances
100
120
150
180
220
270
330
390
470
560
680
820
1,000
1,200
1,500
1,800
2,200
2,700
3,300
3,900
4,700
5,600
6,800
8,200
10,000
12,000
15,000
18,000
22,000
27,000
33,000
39,000
47,000
56,000
68,000
82,000
100,000
120,000
150,000
180,000
220,000
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
J, K, M
AVX 3/
Vendor A
Available voltages
KEMET 4/
Vendor B
Available voltages
PRESIDIO
Vendor C
Available voltages
VISHAY
Vendor D
Available voltages
X Y Z A B C X Y Z A B C X Y Z A B C X Y Z A B C
10 16 25 50 100 200 10 16 25 50 100 200 10 16 25 50 100 200 10 16 25 50 100 200
● ● ● ● ● ●
● ● ● ● ● ● ● ● ● ● ●
● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ●
●
● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
2/
2/
2/
2/
● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ● 2/ ●
● ● ● 2/ ●
● ● ● 2/ ●
● ● ● 2/ ●
● ● ●
●
● ● ●
●
● ● ●
● ● ●
●
● ● ●
● ● ●
●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ●
● ● ●
● ●
● ● ●
●
● ● ●
●
● ● ●
● ●
● ●
● ●
1/ Complete PIN shall include symbols to indicate voltage, capacitance tolerance, termination finish, and group C testing
option (see 1.2).
2/ Parts are canceled. Use MIL-PRF-55681/1 or MIL-PRF-55681/7 (see 1.3).
3/ Vendor does not supply tolerance “J” (±5%).
4/ Vendor does not supply termination finish “M”.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
9
Vendor
Vendor CAGE
Vendor name and address
Similar designation 1/
A
04222
AVX Corporation
801 17th Avenue South
Myrtle Beach SC 29577-4245
0805******HT1A
B
31433
Kemet Electronics Corporation
2835 Kemet Way
Simpsonville SC 29681-6202
C0805*********
Plant:
Avenido Eloy Cavazos 7908 Ote.
Col. Rancho Viejo
Guadalupe, N.L., CP 61750, Mexico
C
60212
Presidio Components Incorporated
7169 Construction Court
San Diego CA 92121-2615
HR0805*******NT93
D
SHV71
Vishay Specialty Capacitors
Ramat Gabriel
P.O. Box 852
Migdal HaEmek 10500
Israel
VJ05006*******A***
1/ Parts must be purchased to the DSCC PIN to assure that all performance requirements and tests are met.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05006
REV F
PAGE
10