REVISIONS LT DESCRIPTION Added “J” tolerance (±5%) to all BR and BX capacitors. Added paragraphs 1.3 and 6.4. Revised tables VI, VII, and VIII. Revised the available voltages in table VII for vendors A and C. Changed address of vendor D. Updated tables VII and VIII for vendor D. Canceled PINs that have duplicates in MIL-PRF55681. Added K and M tolerance to BP capacitors. Specified the life test sample size. Updated tables VI, VII, and VIII. Updated tables VII, and VIII for vendor C. A B C D E F DATE APPROVED 21 April 2008 Michael A. Radecki 22 January 2009 Michael A. Radecki 1 July 2010 9 November 2010 Michael A. Radecki Michael A. Radecki 13 October 2011 Michael A. Radecki 23 March 2012 Michael A. Radecki CURRENT DESIGN ACTIVITY CAGE CODE 037Z3 HAS CHANGED NAMES TO: DLA LAND AND MARITIME COLUMBUS, OHIO 43218-3990 Prepared in accordance with ASME Y14.100 REV STATUS OF PAGES PMIC N/A Source Control drawing REV F F F F F F F F F F PAGES 1 2 3 4 5 6 7 8 9 10 PREPARED BY MICHAEL A. RADECKI Original date of drawing CHECKED BY DESIGN ACTIVITY DEFENSE SUPPLY CENTER, COLUMBUS COLUMBUS, OH TITLE CAPACITORS, FIXED, CERAMIC, CHIP, 0805 11 April 2005 MICHAEL A. RADECKI APPROVED BY KENDALL A. COTTONGIM SIZE A REV AMSC N/A CODE IDENT. NO. 037Z3 DWG NO. F PAGE 05006 1 OF 10 5910-2012-E07 1. SCOPE 1.1 Scope. This drawing and MIL-PRF-55681 describe the requirements for ceramic, chip. This drawing offers capacitors with higher capacitance values and lower voltages than those currently offered in MIL-PRF-55681/1 or MIL-PRF-55681/7. 1.2 Part or Identifying Number (PIN) The complete PIN is as follows: 05006- BX 102 B J Z - Drawing number Dielectric (see 1.2.1) Capacitance value (see 1.2.2) Voltage (see 1.2.3) Capacitance tolerance (see 1.2.4) Termination finish (see 1.2.5) Group C testing option (see 1.2.6) 1.2.1 Dielectric. The dielectric type is identified by the following 2 letters as defined in 3.3.1: BP, BR, BX. 1.2.2 Capacitance value. The nominal capacitance value, expressed in picofarads (pF) is identified by a three digit number; the first two digits represent significant figures and the last digit specifies the number of zeros to follow. When the nominal value is less than 10 pF, the letter “R” is used to indicate the decimal point and the succeeding digit(s) of the group represent significant figure(s). 1R0 indicates 1.0 pF; R75 indicates .75 pF; and 0R5 indicates 0.5 pF. See tables VI, VII, and VIII for values. 1.2.3 Voltage. The rated voltage for continuous operation at +125°C is identified by a single letter as shown in table I. TABLE I. Rated voltage. Symbol Rated voltage (volts, dc) X Y Z A B C 10 16 25 50 100 200 1.2.4 Capacitance tolerance. The capacitance tolerance is identified by a single letter in accordance with table II. TABLE II. Capacitance tolerance. Symbol Capacitance tolerance (±) Tolerance applicability C .25 pF BP < 10 pF D .50 pF BP < 10 pF F 1 percent BP ≥ 10 pF G 2 percent BP ≥ 10 pF J 5 percent BP ≥ 10 pF, BR, BX K 10 percent BP ≥ 10 pF, BR, BX M 20 percent BP ≥ 10 pF, BR, BX DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 2 1.2.5 Termination finish. Termination finish is identified by a single letter as shown in table III. TABLE III. Termination finish. Symbol Termination finish M Palladium-silver U Base metallization-barrier metal-solder coated (tin/lead alloy, with a minimum of 4 percent lead). Solder has a melting point of +200°C or less. Solder coat thickness is a minimum of 60 microinches. Z Base metallization-barrier metal-tinned (tin/lead alloy, with a minimum of 4 percent lead) 1.2.6 Group C testing option. To require MIL-PRF-55681 group C testing, use the appropriate letter from table IV. If group C testing is not desired, leave this location blank. NOTE: Ordering group C options that contain a 2,000 hour life test may extend the processing time by 90 days or more. TABLE IV. Group C testing option. Letter C L M H N/A Group C testing option Full group C 2,000 hour life test only 1,000 hour life test only Low voltage humidity only No group C testing. 1.3 MIL-PRF-55681 vs. DSCC Drawing 05006. When available, MIL-PRF-55681/1 and MIL-PRF-55681/7 capacitors are preferred over DSCC Drawing 05006 capacitors. The military specification requires failure rate level verification and provides additional quality assurance provisions that are not required in this drawing. Refer to tables VI and VIII for MIL-PRF-55681/1 and MIL-PRF-55681/7 availability guidance. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. 2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract (See 6.2). DEPARTMENT OF DEFENSE SPECIFICATIONS MIL-PRF-55681 - MIL-PRF-55681/1 - MIL-PRF-55681/7 - Capacitor, Chip, Multiple Layer, Fixed, Unencapsulated, Ceramic Dielectric, Established Reliability and Non-Established Reliability, General Specification For. Capacitors, Chip, Multiple Layer, Fixed, Ceramic Dielectric, Established Reliability and Non-Established Reliability, Styles CDR01, CDR02, CDR03, and CDR04. Capacitors, Chip, Multiple Layer, Fixed, Ceramic Dielectric, Established Reliability and Non-Established Reliability, Style CDR31, Metric. DEPARTMENT OF DEFENSE STANDARDS MIL-STD-202 MIL-STD-1285 - Electronic and Electrical Components, Test Methods for. Marking of Electrical and Electronic Parts. (Copies of these documents are available online at https://assist.daps.dla.mil/quicksearch/ or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 3 L W T Y Dimensions L ± .008 W ± .008 T Max Y ± .008 .080 .050 .055 .020 Inches .008 .020 .050 .055 .080 mm 0.20 0.51 1.27 1.40 2.03 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Dimensions and tolerances are for bare chips. For solder coated terminations (symbol U), add .020 inch (0.51 mm) to the positive length tolerance and .015 inch (0.38 mm) to the positive width and thickness tolerances. FIGURE 1. Case dimensions and configuration. 2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-55681, and as specified herein. Unless otherwise stated, these capacitors shall be capable of meeting all electrical, environmental, and mechanical requirements of MIL-PRF-55681. 3.2 Interface and physical dimensions. The interface and physical dimensions shall be as specified in MIL-PRF-55681 and herein (see figure 1). 3.2.1 Tin plated finishes. Tin plating is prohibited as a final finish or as an undercoat. Tin-lead (Sn-Pb) finishes are acceptable provided that the minimum lead content is 4 percent (see 6.4). 3.3 Electrical characteristics. DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 4 3.3.1 Dielectric type. The dielectric type shall be BP (±30 ppm/°C), BR (+15, -40 percent) or BX (+15, -25 percent) ceramic in accordance with MIL-PRF-55681. TABLE V. Voltage-temperature limits. Symbol Capacitance change with reference to +25°C Step A through step D of MIL-PRF-55681 table XIII BP 0 ± 30 ppm/°C Percent rated voltage 100 Step E through step G of MIL-PRF-55681 table XIII BR ± 15 percent 100 0 ± 30 ppm/°C +15, -40 percent BX ± 15 percent 100 +15, -25 percent 3.3.2 Capacitance. Capacitance shall be in accordance with tables VI, VII, and VIII when measured in accordance with method 305 of MIL-STD-202. The following conditions shall apply: a. Test frequency: 1 MHz ±50kHz (for all BP characteristic capacitors ≤ 1,000 pF); or 1kHz ±50Hz for all other capacitors. b. Test voltage: 1.0 volt ±0.2 volt rms. 3.3.3 Dissipation factor (+25°C). The dissipation factor shall not exceed 0.15 percent for BP characteristic capacitors, 5.0 percent for 10V BR and BX characteristic capacitors, 3.5 percent for 16V and 25V BR and BX characteristic capacitors, and 2.5 percent for 50V to 200V BR and BX characteristic capacitors. 3.3.4 Insulation resistance. At +25°C: minimum of 100,000 megohms or 1,000 megohm-microfarads, whichever is less. At +125°C: minimum of 10,000 megohms or 100 megohm-microfarads, whichever is less for BR and BX dielectrics; and minimum of 1,000 megohms or 10 megohm-microfarads, whichever is less for BP dielectric. 3.4 Solderability. In accordance with MIL-PRF-55681, except the sample size shall be 5 pieces with zero defectives permitted. 3.5 Moisture resistance. In accordance with MIL-PRF-55681, with the following exceptions: a. Polarizing voltage shall be rated voltage. b. Testing may be performed on chips with a larger width and/or length as long as they are cut from the same wafer(s) as those used for production. 3.6 Marking. As a minimum, marking shall be on the package due to the small size of the chips. The package marking shall be in accordance with MIL-STD-1285, except the PIN shall be as specified in paragraph 1.2 with manufacturer’s name or CAGE code and date code. The manufacturer may, at their option, mark some information on the chips. 3.7 Manufacturer eligibility. To be eligible for listing as an approved source of supply, a manufacturer shall be listed in the MIL-PRF-55681 Qualified Products Database for at least one part, or perform the group A and group C inspections specified herein on a sample of parts agreed upon by the manufacturer and DLA Land and Maritime-VAT. 3.8 Certificate of compliance. A certificate of compliance shall be required from manufacturers requesting to be an approved source of supply. 3.9 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. 3.10 Workmanship. In accordance with MIL-PRF-55681. 4. VERIFICATION 4.1 Qualification inspection. Qualification inspection is not required. DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 5 4.2 Conformance inspection. 4.2.1 Inspection of product for delivery. Inspection of product for delivery shall consist of all tests specified in group A of MIL-PRF-55681. ESR testing and PPM testing and calculation are not applicable. When optional group C testing is requested, terminal strength and series resonance are not applicable. In addition, the life test sample shall be 25 with one defective permitted. 5. PACKAGING 5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control Point’s packaging activities within the Military Service or Defense Agency, or within the military service’s system commands. Packaging data retrieval is available from the managing Military Department’s or Defense Agency’s automated packaging files, CD-ROM products, or by contacting the responsible packaging activity. 6. NOTES (This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.) 6.1 Intended use. Capacitors conforming to this drawing are intended for use when military specifications do not exist and qualified military devices that will perform the required function are not available for OEM application. This drawing is intended exclusively to prevent the proliferation of unnecessary duplicate specifications, drawings, and stock catalog listings. When a military specification exists and the product covered by this drawing has been qualified for listing, this drawing becomes obsolete and will not be used for new design. 6.2 Ordering data. The contract or purchase order should specify the following: a. Complete PIN (see 1.2). b. Requirements for delivery of one copy of the conformance inspection data or certificate of compliance that parts have passed conformance inspection with each shipment of parts by the manufacturer. c. Requirements for notification of change of product to acquiring activity, if applicable. d. Requirements for packaging and packing. 6.3 Replaceability. Capacitors covered by this drawing will replace the same commercial device covered by a contractor-prepared specification or drawing. 6.4 Tin whisker growth. The use of alloys with tin content greater than 97 percent, by mass, may exhibit tin whisker growth problems after manufacture. Tin whiskers may occur anytime from a day to years after manufacture and can develop under typical operating conditions, on products that use such materials. Conformal coatings applied over top of a whisker-prone surface will not prevent the formation of tin whiskers. Alloys of 3 percent lead, by mass, have shown to inhibit the growth of tin whiskers. For additional information on this matter, refer to ASTM-B545 (Standard Specification for Electrodeposited Coatings of Tin). 6.5 Users of record. Coordination of this document for future revisions is coordinated only with the approved sources of supply and the users of record of this document. Requests to be added as a recorded user of this drawing should be in writing to: DLA Land and Maritime, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, by e-mail to [email protected], or by telephone (614) 692-4709 or DSN 850-4709. 6.6 Approved sources of supply. Approved sources of supply are listed herein. Additional sources will be added as they become available. For assistance in the use of this drawing, contact DLA Land and Maritime, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990, by e-mail to [email protected], or by telephone (614) 692-4709 or DSN 850-4709. 6.7 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue. DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 6 TABLE VI. BP dielectric electrical characteristics. DSCC Drawing 05006- 1/ BP0R5- - - BP1R0- - - BP1R2- - - BP1R5- - - BP1R8- - - BP2R2- - - BP2R7- - - BP3R3- - - BP3R9- - - BP4R7- - - BP5R6- - - BP6R8- - - BP8R2- - - BP100- - - BP120- - - BP150- - - BP180- - - BP220- - - BP270- - - BP330- - - BP390- - - BP470- - - BP560- - - BP680- - - BP820- - - BP101- - - BP121- - - BP151- - - BP181- - - BP221- - - BP271- - - BP331- - - BP391- - - BP471- - - BP561- - - BP681- - - BP821- - - BP102- - - BP122- - - BP152- - - BP182- - - BP222- - - BP272- - - BP332- - - BP392- - - BP472- - - BP562- - - BP682- - - BP822- - - - Capacitance pF .5 1.0 1.2 1.5 1.8 2.2 2.7 3.3 3.9 4.7 5.6 6.8 8.2 10 12 15 18 22 27 33 39 47 56 68 82 100 120 150 180 220 270 330 390 470 560 680 820 1,000 1,200 1,500 1,800 2,200 2,700 3,300 3,900 4,700 5,600 6,800 8,200 Available tolerances C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D C, D F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M F, G, J, K, M AVX Vendor A Available voltages X Y Z A B C 10 16 25 50 100 200 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2/ ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2/ ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● KEMET 3/ Vendor B Available voltages PRESIDIO Vendor C Available voltages VISHAY Vendor D Available voltages X Y Z A B C X Y Z A B C X Y Z A B C 10 16 25 50 100 200 10 16 25 50 100 200 10 16 25 50 100 200 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2/ ● ● ● ● ● 2/ ● ● ● ● ● 2/ ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2/ 2/ 2/ ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 1/ Complete PIN shall include symbols to indicate voltage, capacitance tolerance, termination finish, and group C testing option (see 1.2). 2/ Parts are canceled. Use MIL-PRF-55681/1 or MIL-PRF-55681/7 (see 1.3). 3/ Vendor does not supply termination finish “M”. DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 7 TABLE VII. BR dielectric electrical characteristics. DSCC Drawing 05006- 1/ BR101- - - BR121- - - BR151- - - BR181- - - BR221- - - BR271- - - BR331- - - BR391- - - BR471- - - BR561- - - BR681- - - BR821- - - BR102- - - BR122- - - BR152- - - BR182- - - BR222- - - BR272- - - BR332- - - BR392- - - BR472- - - BR562- - - BR682- - - BR822- - - BR103- - - BR123- - - BR153- - - BR183- - - BR223- - - BR273- - - BR333- - - BR393- - - BR473- - - BR563- - - BR683- - - BR823- - - BR104- - - BR124- - - BR154- - - BR184- - - BR224- - - BR334- - - BR474- - - BR684- - - BR105- - - - Capacitance pF 100 120 150 180 220 270 330 390 470 560 680 820 1,000 1,200 1,500 1,800 2,200 2,700 3,300 3,900 4,700 5,600 6,800 8,200 10,000 12,000 15,000 18,000 22,000 27,000 33,000 39,000 47,000 56,000 68,000 82,000 100,000 120,000 150,000 180,000 220,000 330,000 470,000 680,000 1,000,000 Available tolerances J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M AVX 2/ Vendor A Available voltages KEMET 3/ Vendor B Available voltages PRESIDIO Vendor C Available voltages X Y Z A B C X Y Z A B C X Y Z A B C 10 16 25 50 100 200 10 16 25 50 100 200 10 16 25 50 100 200 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● VISHAY Vendor D Available voltages X Y Z A B C 10 16 25 50 100 200 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 1/ Complete PIN shall include symbols to indicate voltage, capacitance tolerance, termination finish, and group C testing option (see 1.2). 2/ Vendor does not supply tolerance “J” (±5%). 3/ Vendor does not supply termination finish “M”. DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 8 TABLE VIII. BX dielectric electrical characteristics. DSCC Drawing 05006- 1/ BX101- - - BX121- - - BX151- - - BX181- - - BX221- - - BX271- - - BX331- - - BX391- - - BX471- - - BX561- - - BX681- - - BX821- - - BX102- - - BX122- - - BX152- - - BX182- - - BX222- - - BX272- - - BX332- - - BX392- - - BX472- - - BX562- - - BX682- - - BX822- - - BX103- - - BX123- - - BX153- - - BX183- - - BX223- - - BX273- - - BX333- - - BX393- - - BX473- - - BX563- - - BX683- - - BX823- - - BX104- - - BX124- - - BX154- - - BX184- - - BX224- - - - Capacitance pF Available tolerances 100 120 150 180 220 270 330 390 470 560 680 820 1,000 1,200 1,500 1,800 2,200 2,700 3,300 3,900 4,700 5,600 6,800 8,200 10,000 12,000 15,000 18,000 22,000 27,000 33,000 39,000 47,000 56,000 68,000 82,000 100,000 120,000 150,000 180,000 220,000 J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M J, K, M AVX 3/ Vendor A Available voltages KEMET 4/ Vendor B Available voltages PRESIDIO Vendor C Available voltages VISHAY Vendor D Available voltages X Y Z A B C X Y Z A B C X Y Z A B C X Y Z A B C 10 16 25 50 100 200 10 16 25 50 100 200 10 16 25 50 100 200 10 16 25 50 100 200 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2/ 2/ 2/ 2/ ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 2/ ● ● ● ● 2/ ● ● ● ● 2/ ● ● ● ● 2/ ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● 1/ Complete PIN shall include symbols to indicate voltage, capacitance tolerance, termination finish, and group C testing option (see 1.2). 2/ Parts are canceled. Use MIL-PRF-55681/1 or MIL-PRF-55681/7 (see 1.3). 3/ Vendor does not supply tolerance “J” (±5%). 4/ Vendor does not supply termination finish “M”. DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 9 Vendor Vendor CAGE Vendor name and address Similar designation 1/ A 04222 AVX Corporation 801 17th Avenue South Myrtle Beach SC 29577-4245 0805******HT1A B 31433 Kemet Electronics Corporation 2835 Kemet Way Simpsonville SC 29681-6202 C0805********* Plant: Avenido Eloy Cavazos 7908 Ote. Col. Rancho Viejo Guadalupe, N.L., CP 61750, Mexico C 60212 Presidio Components Incorporated 7169 Construction Court San Diego CA 92121-2615 HR0805*******NT93 D SHV71 Vishay Specialty Capacitors Ramat Gabriel P.O. Box 852 Migdal HaEmek 10500 Israel VJ05006*******A*** 1/ Parts must be purchased to the DSCC PIN to assure that all performance requirements and tests are met. DEFENSE SUPPLY CENTER, COLUMBUS SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIO A 037Z3 05006 REV F PAGE 10