DLA 05002

REVISIONS
LTR
A
B
C
D
E
F
DESCRIPTION
Added AVX as an approved source of supply.
Changed suggested sources to approved sources.
Added approved source of supply. Revised table IV.
Added 6.4. Removed table from 3.3.1.
Changed address of vendor C.
Removed an approved source of supply.
Added a new voltage rating and updated vendor
offerings.
Added an approved source of supply.
DATE
APPROVED
13 December 2005
William E. Sindelar
17 April 2008
Michael A. Radecki
1 July 2010
12 June 2013
Michael A. Radecki
Michael A. Radecki
26 September 2013
Michael A. Radecki
4 May 2015
Michael A. Radecki
CURRENT DESIGN ACTIVITY CAGE CODE 037Z3
HAS CHANGED NAMES TO:
DLA LAND AND MARITIME
COLUMBUS, OHIO 43218-3990
Prepared in accordance with ASME Y14.100
REV STATUS
OF PAGES
PMIC N/A
REV
F
F
F
F
F
F
F
F
PAGES
1
2
3
4
5
6
7
8
PREPARED BY
MICHAEL A. RADECKI
Original date of
drawing
CHECKED BY
MICHAEL A. RADECKI
3 January 2005
APPROVED BY
KENDALL A. COTTONGIM
SIZE
A
REV
AMSC N/A
DESIGN ACTIVITY
DEFENSE SUPPLY CENTER, COLUMBUS
COLUMBUS, OH
TITLE
CAPACITOR, FIXED, CERAMIC, CHIP, 0603, HIGH
FREQUENCY, BP
CODE IDENT. NO.
037Z3
DWG NO.
F
PAGE
05002
1
OF
8
5910-2015-E14
1. SCOPE
1.1 Scope. This drawing and MIL-PRF-55681 describe the requirements for ceramic, chip.
1.2 Part or Identifying Number (PIN) The complete PIN is as follows:
05002-
2R0
B
C
Z
-
Drawing
number
Capacitance
value
(see 1.2.1)
Voltage
(see 1.2.2)
Capacitance
tolerance
(see 1.2.3)
Termination
finish
(see 1.2.4)
Group C
testing option
(see 1.2.5)
1.2.1 Capacitance value. The nominal capacitance value, expressed in picofarads (pF) is identified by a three digit number; the first
two digits represent significant figures and the last digit specifies the number of zeros to follow. When the nominal value is less than 10
pF, the letter “R” is used to indicate the decimal point and the succeeding digit(s) of the group represent significant figure(s). 1R0
indicates 1.0 pF; R75 indicates .75 pF; and 0R5 indicates 0.5 pF. See table IV for values.
1.2.2 Voltage. The rated voltage for continuous operation at +125°C is identified by a single letter as shown in table I.
TABLE I. Rated voltage.
Symbol
Rated voltage (volts, dc)
Z
A
B
N
C
K
25
50
100
150
200
250
1.2.3 Capacitance tolerance. The capacitance tolerance is identified by a single letter in accordance with table II.
TABLE II. Capacitance tolerance.
Symbol
Capacitance tolerance (±)
A
B
C
D
F
G
J
K
M
.05 pF
.1 pF
.25 pF
.50 pF
1 percent
2 percent
5 percent
10 percent
20 percent
1.2.4 Termination finish. Termination finish is identified by a single letter as shown in table III.
TABLE III. Termination finish.
Symbol
Termination finish
M
Palladium-silver
Z
Base metallization-barrier metal-tinned (tin/lead alloy, with a minimum of 4 percent lead)
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05002
REV F
PAGE
2
1.2.5 Group C testing option. To require MIL-PRF-55681 group C testing, use the appropriate letter from the table below. If group C
testing is not desired, leave this location blank. NOTE: Ordering group C options that contain a 2,000 hour life test may extend the
processing time by 90 days or more.
Letter
C
L
M
H
N/A
Group C testing option
Full group C
2,000 hour life test only
1,000 hour life test only
Low voltage humidity only
No group C testing.
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3, 4 and 5 of this specification. This section does not
include documents cited in other sections of this specification or recommended for additional information or as examples. While every
effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified
requirements of documents in sections 3 and 4 of this specification, whether or not they are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards, and handbooks form a part of this
document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or
contract (See 6.2).
DEPARTMENT OF DEFENSE SPECIFICATIONS
MIL-PRF-55681
-
Capacitor, Chip, Multiple Layer, Fixed, Unencapsulated, Ceramic Dielectric, Established Reliability and
Non-Established Reliability, General Specification For.
DEPARTMENT OF DEFENSE STANDARDS
MIL-STD-202
MIL-STD-1285
-
Electronic and Electrical Component Parts, Test Methods for.
Marking of Electrical and Electronic Parts.
(Copies of these documents are available online at http://quicksearch.dla.mil/.)
2.3 Order of precedence. Unless otherwise noted herein or in the contract, in the event of a conflict between the text of this
document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes
applicable laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Item requirements. The individual item requirements shall be in accordance with MIL-PRF-55681, and as specified herein.
These capacitors shall be capable of meeting all electrical, environmental, and mechanical requirements of MIL-PRF-55681, unless
otherwise stated.
3.2 Pure tin. The use of pure tin, as an underplate or final finish, is prohibited both internally and externally. Tin content of capacitor
components and solder shall not exceed 97 percent. Tin shall be alloyed with a minimum of 3 percent lead (see 6.4).
3.3 Interface and physical dimensions. The interface and physical dimensions shall be as specified in MIL-PRF-55681 and herein (see
figure 1).
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05002
REV F
PAGE
3
L
W
T
Y
Dimensions
L
± .006
W
± .006
T
Max
Y
± .006
.063
.032
.036
.014
Inches
.006
.014
.032
.036
.063
mm
0.15
0.36
0.81
0.91
1.60
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
FIGURE 1. Case dimensions and configuration.
3.4 Electrical characteristics.
3.4.1 Dielectric type. The dielectric type shall be BP (±30 ppm/°C) ceramic in accordance with MIL-PRF-55681.
3.4.2 Capacitance. Capacitance shall be in accordance with table IV when measured in accordance with method 305 of MIL-STD-202.
The following conditions shall apply:
≤ 1,000 pF
> 1,000 pF
1 MHz ± 50 kHz
1 V rms ± .2 V rms
1 kHz ± 50 Hz
1 V rms ± .2 V rms
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05002
REV F
PAGE
4
3.4.3 Dissipation factor (+25°C). When measured at the frequency and voltage specified in 3.4.2, the dissipation factor shall be 0.05
percent.
3.4.4 Insulation resistance. At +25°C: minimum of 100,000 megohms or 1,000 megohm-microfarads, whichever is less.
At +125°C: minimum of 1,000 megohms or 10 megohm-microfarads, whichever is less.
3.5 Solderability. In accordance with MIL-PRF-55681, except the sample size shall be 5 pieces with zero defectives permitted.
3.6 Moisture resistance. In accordance with MIL-PRF-55681, with the following exceptions:
a. Polarizing voltage shall be rated voltage.
b. Testing may be performed on chips with a larger width and/or length as long as they are cut from the same wafer(s) as those used
for production.
3.7 Marking. As a minimum, marking shall be on the package due to the small size of the chips. The package marking shall be in
accordance with MIL-STD-1285, except the PIN shall be as specified in paragraph 1.2 with manufacturer’s name or CAGE code and date
code. The manufacturer may, at their option, mark some information on the chips. Suggested marking is the 2 digit EIA capacitance code.
3.8 Manufacturer eligibility. To be eligible for listing as an approved source of supply, a manufacturer shall be listed on the MIL-PRF55681 Qualified Products List for at least one part, or perform the group A and group C inspections of MIL-PRF-55681 on a sample of
parts agreed upon by the manufacturer and DLA Land and Maritime-VA.
3.9 Certificate of compliance. A certificate of compliance shall be required from manufacturers requesting to be an approved source of
supply.
3.10 Recycled, recovered, environmentally preferable, or biobased materials. Recycled, recovered, environmentally preferable, or
biobased materials should be used to the maximum extent possible provided that the material meets or exceeds the operational and
maintenance requirements, and promotes economically advantageous life cycle costs.
3.11 Workmanship. In accordance with MIL-PRF-55681.
4. VERIFICATION
4.1 Qualification inspection. Qualification inspection is not required.
4.2 Conformance inspection.
4.2.1 Inspection of product for delivery. Inspection of product for delivery shall consist of all tests specified in group A of MIL-PRF-55681.
ESR testing and PPM testing and calculation are not applicable. When optional group C testing is requested, terminal strength and series
resonance are not applicable.
5. PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified in the contract or order (see 6.2). When
packaging of materiel is to be performed by DoD or in-house contractor personnel, these personnel need to contact the responsible
packaging activity to ascertain packaging requirements. Packaging requirements are maintained by the Inventory Control Point’s
packaging activities within the Military Service or Defense Agency, or within the military service’s system commands. Packaging data
retrieval is available from the managing Military Department’s or Defense Agency’s automated packaging files, CD-ROM products, or
by contacting the responsible packaging activity.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05002
REV F
PAGE
5
6. NOTES
(This section contains information of a general or explanatory nature that may be helpful, but is not mandatory.)
6.1 Intended use. Capacitors conforming to this drawing are intended for use when military specifications do not exist and qualified
military devices that will perform the required function are not available for OEM application. This drawing is intended exclusively to prevent
the proliferation of unnecessary duplicate specifications, drawings, and stock catalog listings. When a military specification exists and the
product covered by this drawing has been qualified for listing, this drawing becomes obsolete and will not be used for new design.
6.2 Ordering data. The contract or purchase order should specify the following:
a. Complete PIN (see 1.2).
b. Requirements for delivery of one copy of the conformance inspection data or certificate of compliance that parts have passed
conformance inspection with each shipment of parts by the manufacturer.
c. Requirements for notification of change of product to acquiring activity, if applicable.
d. Requirements for packaging and packing.
6.3 Replaceability. Capacitors covered by this drawing will replace the same commercial device covered by a contractor-prepared
specification or drawing.
6.4 Tin whisker growth. The use of alloys with tin content greater than 97 percent, by mass, may exhibit tin whisker growth problems
after manufacture. Tin whiskers may occur anytime from a day to years after manufacture and can develop under typical operating
conditions, on products that use such materials. Conformal coatings applied over top of a whisker-prone surface will not prevent the
formation of tin whiskers. Alloys of 3 percent lead, by mass, have shown to inhibit the growth of tin whiskers. For additional information
on this matter, refer to ASTM-B545 (Standard Specification for Electrodeposited Coatings of Tin).
6.5 Users of record. Coordination of this document for future revisions is coordinated only with the approved sources of supply and
the users of record of this document. Requests to be added as a recorded user of this drawing may be achieved online at
[email protected] or if in writing to: DLA Land and Maritime, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990 or by
telephone (614) 692-4709 or DSN 850-4709.
6.6 Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from
the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any
inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the
entire content irrespective of the marginal notations and relationship to the last previous issue.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05002
REV F
PAGE
6
TABLE IV. Electrical characteristics.
DSCC
Drawing
05002- 1/
0R1- - - 0R2- - - 0R3- - - 0R4- - - 0R5- - - 0R6- - - 0R7- - - 0R8- - - 0R9- - - 1R0- - - 1R1- - - 1R2- - - 1R3- - - 1R4- - - 1R5- - - 1R6- - - 1R7- - - 1R8- - - 1R9- - - 2R0- - - 2R1- - - 2R2- - - 2R4- - - 2R7- - - 3R0- - - 3R3- - - 3R6- - - 3R9- - - 4R3- - - 4R7- - - 5R1- - - 5R6- - - 6R2- - - 6R8- - - 7R5- - - 8R2- - - 9R1- - - 100- - - 110- - - 120- - - 130- - - 150- - - 180- - - 200- - - 220- - - 240- - - 270- - - 300- - - 330- - - -
Capacitance
pF
Available
tolerances
.1
.2
.3
.4
.5
.6
.7
.8
.9
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2
2.1
2.2
2.4
2.7
3
3.3
3.6
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
11
12
13
15
18
20
22
24
27
30
33
A, B
A, B
A, B, C
A, B, C
A, B, C
A, B, C
A, B, C
A, B, C
A, B, C
A, B, C
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
A, B, C, D
B, C, J, K, M
B, C, J, K, M
B, C, J, K, M
B, C, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
Vendor A
Vendor B 2/
Vendor C
Available voltages
Available voltages
Available voltages
Z A B N C K Z A B N C K
25 50 100 150 200 250 25 50 100 150 200 250
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ●
● ●
● ● ●
● ●
● ●
● ●
● ●
● ● ●
● ●
● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
Z A B N C K
25 50 100 150 200 250
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
See footnote at end of table.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05002
REV F
PAGE
7
TABLE IV. Electrical characteristics. – Continued.
DSCC
Drawing
05002- 1/
360- - - 390- - - 430- - - 470- - - 510- - - 560- - - 620- - - 680- - - 750- - - 820- - - 910- - - 101- - - -
Capacitance
pF
36
39
43
47
51
56
62
68
75
82
91
100
Available
tolerances
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
F, G, J, K, M
Vendor A
Vendor B 2/
Vendor C
Available voltages
Available voltages
Available voltages
Z A B N C K Z A B N C K
25 50 100 150 200 250 25 50 100 150 200 250
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ●
● ● ●
● ●
● ● ●
● ●
● ● ●
● ●
● ● ●
● ●
● ● ●
●
● ● ●
●
● ● ●
●
● ● ●
●
Z A B N C K
25 50 100 150 200 250
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
● ● ● ● ● ●
1/ Complete PIN shall include symbols to indicate voltage, capacitance tolerance, termination finish,
and group C testing option (see 1.2).
2/ Vendor does not supply tolerance “A” (±.05pF).
6.7 Approved sources of supply. Approved sources of supply are listed herein. Additional sources will be added as they become
available. Assistance in the use of this drawing may be obtained online at [email protected] or by contacting DLA Land and
Maritime, ATTN: VAT, Post Office Box 3990, Columbus, OH 43218-3990 or by telephone (614) 692-4709 or DSN 850-4709.
Vendor
Vendor CAGE
Vendor name and address
A
29990
American Technical Ceramics Corporation
One Norden Lane
Huntington Station, NY 11746-2141
3Q6G1
Plant:
2201 Corporate Square Boulevard
Jacksonville, FL 32216-1921
B
SHV71
Vishay Specialty Capacitors
Ramat Gabriel
P.O. Box 852
Migdal HaEmek 10500
Israel
C
60212
Presidio Components Incorporated
7169 Construction Court
San Diego, CA 92121-2615
Similar designation 1/
600S****W150
VJ0603*******A*7Q
0603NPQ********
1/ Parts must be purchased to the DSCC PIN to assure that all performance requirements and tests are met.
DEFENSE SUPPLY CENTER, COLUMBUS
SIZE
CODE IDENT NO.
DWG NO.
COLUMBUS, OHIO
A
037Z3
05002
REV F
PAGE
8