English User's Manual

User's Guide
True RMS AC Voltage/Current
Datalogger
Model DL150
Introduction
Congratulations on your purchase of this Voltage or Current datalogger. With this meter, you can
monitor and log data over long periods of time and then easily transfer the data to a pc for viewing
and evaluation. The LCD display provides real time data, Max/Min data and time information. This
meter is shipped fully tested and calibrated and, with proper use, will provide years of reliable
service.
Safety
Warning!

Do not attempt to make measurement in flammable gaseous areas!

When testing a non-insulated cable, pay attention to avoid short circuits.

Do not attempt to use the instrument when your hand is wet!

Do not input over range during measurements.

Never open the battery cover during measurements.

Stop using the instrument when there is any structural defect or exposed metal parts.

Do not install substitute parts or make modifications on the meter.

Never replace the battery in moist areas.

Ensure the meter is disconnected and switch off before opening the battery cover to replace
the battery.

Do not attempt to place the instrument in high vibration areas.

Do not expose the meter to direct sunlight, high temperature and high moisture environment.

Switch off the meter after use. Remove the AAA batteries when the meter will be stored for a
period of time..

When cleaning, do not use abrasives or solvents on the meter, use a damp cloth and mild
detergent only.
2
DL150-EU-EN V2.5 5/13
Description and Button Functions
1. LCD Description
:
:
:
:
:
:
Auto power off setting, the meter will automatically
shuts off after 5mins without any button presses.
Average peak measure and record mode selected
(about 195ms)
Recording status. After the record mode is set up by the software, press the
START/STOP button for more than 4 seconds to begin recording. This icon will be
displayed and indicates the meter is recording data. Press the same button again for
more than 4 seconds to stop recording.
Record until full is selected. When the memory is full, the datalogger will stop recording.
:
:
:
Normal record mode is selected
Capture record mode is selected. Records the sine
wave when the measure value exceeds the Capture
Detection set level.
Continuous recording is selected. When the memory is full, the data will overwrite the
oldest data.
Memory full and recording has stopped.
Battery sign, when display completely the battery power is full. When there is only a
frame icon displayed, the battery is exhausted and should be replaced with a new one.
3
DL150-EU-EN V2.5 5/13
2. AC adaptor Jack
3. ON/OFF Button
4. MAX/MIN : Press the button one time to display the MAX
(maximum) reading . Press again to display the MIN (minimum)
reading. A third press will exit MAX/MIN mode. The meter will
automatically exit MAX/MIN mode in 10 seconds if no button is
pressed.
5. CH Input Jack: Insert the current or voltage sensor to this COM to
measure and record the data.
1
2
8
3
7
4
6
5
6. PEAK HOLD: In the non-PEAK measurement mode, press the
PEAK HOLD button to display the average Peak value of the
present value. Press the button again to exit PEAK display. The meter will automatically exit in
10s if no button is pressed.
7. START/STOP: Press the START/STOP button for one time to pause data. Press again to
resume. After setting the record mode, press this button for more than 4 seconds and then
release it after REC is shown on the LCD. The meter will measure and record data according to
the software setup.
8. USB Port
9. AC Current Clamp Jaw: Clamp the jaws around a single
conductor for AC current measurements to 200A
10. Jaw Opening Trigger:
9
11. CH Plug:
10
11
12. AC Voltage Probes or Alligator clips
13. Voltage module
12
14. CH Plug
13
14
4
DL150-EU-EN V2.5 5/13
Operation
1.
Install 4 fresh AAA batteries or connect the AC adaptor.
2.
Set-up the datalogger using the software provided.
3.
Connect the voltage test leads or the current probe to the meter and hen to the AC source to
be measured.
4.
Press and Hold the START/STOP button for four seconds to start recording. The “REC” icon
will appear in the display indication that recording has begun.
5.
Press and Hold the START/STOP button for four seconds to stop recording. The “REC” icon
will disappear from the display.
6.
Remove the probe, connect the datalogger to a PC and use the supplied software to download
the data.
7.
After each recording you will need to connect to the PC and supplied software to download the
data and set up for the next recording.
You, as the end user, are legally bound (Battery ordinance) to return all used batteries and
accumulators; disposal in the household garbage is prohibited!
You can hand over your used batteries / accumulators at collection points in your community
or wherever batteries / accumulators are sold!
Disposal: Follow the valid legal stipulations in respect of the disposal of the device at the
end of its lifecycle.
Note: If the clock does not set to the correct time, replace the 3V button battery.
Software Introduction
1.
Place the CD in the drive and then follow the on-screen installation instruction.
2.
After the software is installed, keep the CD in the drive and connect the datalogger to the PC
by the USB cable.
3.
A USB Driver installation window will pop-up. Follow the directions to install the driver.
System Required:
Windows 2000, Windows XP, Vista, Windows 7, or Windows 8
Minimum Hardware Required:
PC or NoteBook with Pentium 90MHz or higher 32 MB RAM
At least 7 MB hard disk space available to install Datalogger USB software
Recommended display resolution 1024 x 768 with High Color (16 bit)
Software Operation
The Software operation is described in the HELP file located on the software disk.
5
DL150-EU-EN V2.5 5/13
Specifications
Display
Maximum data points
Channels
Sample rate
Transient capture
Analysis software
Data output
Open input indication
Low battery indication
Power supply
Battery life
AC Adaptor
Multi-function LCD
100,000
Single channel, TRMS AC Voltage or Current
1s to 24h selectable
>0.244mS
Windows 2000/XP/ Vista/7/8
USB port
"LO" appears on the LCD
Empty battery symbol appears on the LCD
4 AAA Batteries and 1 CR 3V memory button battery (CR2032 or
equivalent)
5 days (approximately)
9V, 0.5A
Standards
Operating Temperature
Operating Humidity
Current Clamp Jaw opening
Dimensions
Weight
CCCAT III 600V
0 to 50°C (32 to 122°F)
<70% RH
12.7mm (0.5”)
114 x 63 x 34mm (4.5 x 2.5 x 1.3”)
248g (8.7oz.)
Range
Accuracy
Voltage
40Hz to 1kHz
10VAC to 600.0VAC
±2.0%±1V
Current
50/60Hz
10A to 200.0A
±2.0%±1A
Peak Measurement
8.0 to 850.0V
±5.0%
Copyright © 2013 FLIR Systems, Inc. All rights reserved including the right of reproduction in whole or in part in any form ISO‐9001 Certified www.extech.com 6