HEATSINK VIBrick X-FLOW .70

7
8
5
6
1
2
3
4
VICOR CONFIDENTIAL
REV.
THIS DOCUMENT AND THE DATA DISCLOSED HEREIN OR
HEREWITH IS NOT TO BE REPRODUCED, USED OR
DISCLOSED IN WHOLE OR IN PART TO ANYONE WITHOUT
THE PERMISSION OF VICOR CORP.
1
DESCRIPTION
RELEASED PER E120943
GCK
DATE
APPROVED
10/22/12
REJH
F
F
.70
17.8
1.913±.010
48.60±.25
<>
R.060
1.52
(4) PL.
R.063
1.59
(6) PL.
R.015
.38
TYP
.085±.015
2.16±.38
.386
9.81
<>
.24
6.1
(2) PL.
.48
12.2
(2) PL.
.208
5.28
(17) PL.
E
1.467
37.26
<>
E
.24
6.1
(2) PL.
.48
12.2
(2) PL.
3.536±.015
89.81±.38
3.706±.010
94.14±.25
<>
2.934
74.52
<>
D
D
.24
6.1
(2) PL.
FULL R
TYP
.080
2.03
<>
C
1.754
44.55
<>
<>
.001in/in [.03mm/mm]
C
.010
.25
MAX
(6) PL.
1- MATL: ALUMINUM 6063-T5.
.100
2.54
2- CORNERS SHOWN SHARP TO BE .005/[.13] MAX.
.16
4.1
(3) PL.
.16
4.1
(3) PL.
NOTES:
B
.48
12.2
(2) PL.
.050
1.27
TYP
.125±.003
3.18±.08
(6) PL.
<>
R.12
3.0
(12) PL.
B
<> 3- CLEAR FINISH, RoHS COMPLIANT PER CST-0001, LATEST REVISION PER
A.) CHROMIUM FREE, OR
B.) TRIVALENT CHROMIUM IN ACCORDANCE WITH MIL-DTL-5541, TYPE II, CLASS 1A OR 3.
SEE CST-0003 FOR TYPES OF AVAILABLE FINISHES.
4- ALL DIMENSIONS APPLY AFTER PLATING.
5- <> DENOTES CRITICAL CHARACTERISTIC FOR LOT INSPECTION.
6- MAXIMUM STEP BETWEEN ADJOINING CUTTER PASSES TO BE .0005/[.013]
7- BASE PLATE SURFACE PREPARATION PRIOR TO CLEAR FINISH IN
ACCORDANCE WITH WS-0016.
8- REMOVE ALL BURRS AND SHARPE EDGES.
A
DRAWN BY
DATE
Gary Keay
09/26/2012
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE : INCH / [MM]
TOLERANCES ARE:
DECIMALS
ANGLES
X.XX [X.X] = ±0.01 [0.25]
±1°
X.XXX [X.XX] = ±0.005 [0.127]
THIRD ANGLE PROJECTION
DO NOT SCALE DRAWING
8
7
6
5
4
3
2
VICOR
SWD
A
HEATSINK VIBrick X-FLOW .70
SIZE
CAGE CODE
D
67131
SCALE 2:1
DWG NO
REV
39069
SHEET 1 OF 1
1
1