M1302/M5020

M1302/M5020
S-Band Magnetron
M1302/M5020 is designed for the magnetron of S-band radar system.
The frequency range is fixed between 3.04GHz and 3.06GHz. The peak output
power is 25kW Min.
---- MAXIMUM RATINGS ---Min
6.0
-
Max
12.0
100
0.001
1.0
130
Unit
A
kW
Us
kV/us
Anode temperature
-
120
°C
V.S.W.R. at the output coupler
-
1.5:1
-
Max
6.9
8.5
3.06
Unit
V
S
kV
kW
GHz
Peak anode current
Peak anode power input
Duty cycle
Pulse duration
Rate of rise of voltage pulse
---- ELECTRICAL ---Min
5.7
180
7.5
25
3.04
Typical
Heater voltage(Note 1)
6.3
Preheat time
Peak anode voltage (Note 2)
8.0
Peak output power (Note 2)
27
Frequency (Note2)
3.05
Note:
1. Measured with heater voltage of 6.3V and no anode input power, the
heater current limits are 1.1A minimum, 1.4A maximum. For average
pulse input powers greater than 25 watts, the heater voltage must
be reduced within 3 seconds after the application of h. t. according
to the following schedule:
Meat input power(W)
Heater Voltage(V)
Less than 25
6.3
25 to 62
5.3
62 to 100
4.5
2. Measured at peak anode current 8.0A.
For further information on the use of the magnetron, Please contact New
JRC. New JRC reserves the right to change the specification of goods without
notice.