ETC 2J55

2J55
X-Band Magnetron
2J55 is a fixed frequency pulsed type X-band magnetron, designed to
operate in the frequency range of 9345 to 9405 MHz with a peak output
power of 50 kW. It is packaged and waveguide output type and forced
air cooled.
---- MAXIMUM RATINGS ---Peak anode current ················
Perk anode power input ············
Duty cycle ························
Pulse duration ····················
Rate of rise of voltage pulse ·····
Anode temperature ················
V.S.W.R at the output coupler ·····
Min
3.5
-
Max
16.0
230
0.001
2.5
100
100
1.5:1
Unit
A
kW
µs
kV/µs
°C
-
---- ELECTRICAL ---Heater voltage (Note 1) ·········
Preheat time ····················
Peak anode voltage (Note 2) ·····
Peak output power (Note 2) ······
Frequency (Note 2) ··············
Min
5.7
120
11.0
8
9345
Typical
6.3
12.0
–
Max
6.9
13.0
9405
Unit
V
S
kV
kW
MHz
Note 1: Measured with heater voltage of 6.3V and no anode input power,
the heater current 1imits are 0.9A minimum, 1.1A maximum.
For average pulse input powers less than 150 watts the heater
voltage must be reduced within 3 seconds after the application
of h. t. according to the following schedule:
Ef = 6.3 1 −
Pi
volts
150
where Pi=mean input power in watts.
Note 2: Measured at peak anode current 12A
98-3