XWAY™ PHY Ethernet Physical Layer Devices EASY 7071 Reference Board Version 2.3.1 for XWAY™ PHY11G (PEF 7071), Version 1.5 Getting Started Revision 1.0, 2013-12-11 Edition 2013-12-11 Published by Lantiq Deutschland GmbH Lilienthalstraße 15 85579 Neubiberg Germany © 2013 Lantiq Deutschland GmbH All Rights Reserved. Legal Disclaimer The information given in this document is confidential. SUCH INFORMATION SHALL IN NO EVENT BE REGARDED AS A GUARANTEE OF CONDITIONS OR CHARACTERISTICS. WITH RESPECT TO ANY VALUES STATED AS "TYPICAL" AS WELL AS EXAMPLES OR HINTS PROVIDED HEREIN, INCLUDING THOSE RELATED TO USE AND/OR IMPLEMENTATION OR APPLICATION OF COMPONENTS, LANTIQ DEUTSCHLAND GMBH ("LANTIQ") HEREBY DISCLAIMS ANY AND ALL WARRANTIES AND LIABILITIES OF ANY KIND, INCLUDING WITHOUT LIMITATION, WARRANTIES OF NON-INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS OF ANY THIRD PARTY. IN PARTICULAR, THOSE VALUES, EXAMPLES OR HINTS ARE NO WARRANTIES OF A CERTAIN FUNCTIONALITY, CONDITION OR QUALITY OF THE LANTIQ COMPONENT AND ALWAYS HAVE TO BE VERIFIED IN THE TARGET APPLICATION. The information in this document is subject to regular updates and/or corrections via errata sheet(s) or new revisions. It is only valid as updated and/or corrected. Once a new revision or errata sheet is available, it can be downloaded from Lantiq's Competence Center: www.lantiq.com/contact-lantiq Any user of this document must ensure that they only use the latest update- and/or corrected revision. LANTIQ HEREBY DISCLAIMS ANY AND ALL WARRANTIES AND LIABILITIES OF ANY KIND, INCLUDING WITHOUT LIMITATION, WARRANTIES OF NON-INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS OF ANY THIRD PARTY, WITH RESPECT TO PREVIOUS REVISIONS OF THIS DOCUMENT ONCE AN UPDATE OR ERRATA SHEET IS AVAILABLE. Information For further information on technology, delivery terms and conditions and prices, please contact the nearest Lantiq office (www.lantiq.com). Warning Lantiq components must not be used in life-support devices or systems. Life-support devices or systems are those systems intended to be implanted in the human body or to support and/or maintain and sustain and/or protect human life. If they fail, it is reasonable to assume that the health of the user or other persons may be endangered. EASY 7071 Reference Board Version 2.3.1 XWAY™ PHY, Ethernet Physical Layer Devices Revision History: Revision 1.0, 2013-12-11 Previous Revision: None Page Subjects (major changes since last revision) Trademarks of Lantiq CONVERGATE™, COSIC™, DUALFALC™, DUSLIC™, ELIC™, EPIC™, FALC™, GEMINAX™, ISAC™, IWORX™, OCTALFALC™, OCTAT™, QUADFALC™, SCOUT™, SEROCCO™, SICOFI™, SLIC™, SMINT™, SOCRATES™, VINAX™, VINETIC™, XWAY™ Other Trademarks ARM™, Bluetooth™ of Bluetooth SIG Inc. CAT-iq™ of DECT Forum. eCosCentric®, eCos® and eCosPro® of eCosCentric Limited. EPCOS™ of Epcos AG. HYPERTERMINAL™ of Hilgraeve Incorporated. IEC™ of Commission Electrotechnique Internationale. IQfact™ and IQmax™ of LitePoint Corporation. IrDA™ of Infrared Data Association Corporation. ISO™ of INTERNATIONAL ORGANIZATION FOR STANDARDIZATION. MATLAB™ of MathWorks, Inc. NUCLEUS™ of Mentor Graphics Corporation. Linux® of Linus Torvalds. MIPS® of MIPS Technologies, Inc., USA. muRata™ of MURATA MANUFACTURING CO. SOLARIS™ of Sun Microsystems, Inc. Samtec® of Samtec Inc. TEAKLITE™ of CEVA, Inc. TEKTRONIX™ of Tektronix Inc. UNIX™ of X/Open Company Limited. VERILOG™, PALLADIUM™ of Cadence Design Systems, Inc. VxWorks™, WIND RIVER™ of WIND RIVER SYSTEMS. All other trademarks are the property of their respective owners. Last Trademarks Update 2013-09-20 Getting Started 3 Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 Table of Contents Table of Contents Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Content of the EASY 7071 Reference Board Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3 3.1 3.2 3.3 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RGMII and SGMII Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mini USB Device Connector (CON1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connector for 4 Pin UART Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 BOM of EASY 7071 Reference Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 8 8 8 9 Literature References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Getting Started 4 Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 Introduction 1 Introduction This document describes the hardware configuration to get started with the EASY 7071 Reference Board, Version 2.3.1. Please refer to the hardware user’s manual [1] for information about advanced configuration. 1.1 Content of the EASY 7071 Reference Board Kit The reference kit contains: • • EASY 7071 Reference Board, Version 2.3.1 (see Figure 1) Power Source: Via mini USB cable For ordering of EASY 7071 Reference Board Kit, please specify the code “LA000001746”. Figure 1 EASY 7071 Reference Board, Version 2.3.1 Getting Started 5 Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 Block Diagram 2 Block Diagram Figure 2 shows the block diagram of EASY 7071 Reference Board. Mini-B USB Connector TLV62090 5 Vin 3.3 Vout 3.3 V / 50 mA 3.3 V ATxmega16A4U-MH +3.3 V +3V3_GPHY XWAY™ TANTOS-2G Internal 1.5 V GPHY Internal 1 V 1.5 V 1V MDIO 3.3 V / 1V/ 200 mA 260 mA Figure 2 RGMII 25M_OUT XWAY™ TANTOS-2G (PSB 6972) 25M_OUT RGMII 3.3 V / 1.5 V / 150 mA 270 mA XWAY™ PHY11G (PEF 7071) RJ45 XWAY™ PHY11G (PEF 7071) GE LAN Transformer GE LAN Transformer RJ45 SMDIO 3.3 V / 1V/ 200 mA 260 mA Block Diagram of the EASY 7071 Reference Board The EASY 7071 Reference Board consists of the following blocks: • • • • • • • • • • XWAY™ PHY11G (PEF 7071), Version 1.5 devices 2 Giga LAN port (through 5th and 6th ports of XWAY™ TANTOS-2G) JTAG UART connectors for XWAY™ PHY11G (PEF 7071) (4 pins connector) LEDs (controlled by XWAY™ PHY11G) Atmel® microcontroller (ATxmega16A4U-MH) Tactile Switch, DIP 4 Pin 90° (Wuerth Elektronik eiSos GmbH) 1000BASE-T; GE LAN Transformer, (Wuerth Elektronik eiSos GmbH) Connectors (Wuerth Elektronik eiSos GmbH) – Mini-B USB Connector – DIP Pin Header 2 x 3, 2.54 mm – DIP Pin Header 1 x 4, 2.54 mm – RJ45 1 Port Shielded Inductors (Wuerth Elektronik eiSos GmbH) – 600 Ω BEAD 0603 – 120 Ω BEAD 0805 – SMD 4.7 µH 315 mA ±10% 1812 Wound – SMD 1 µH 5.4 A 20% L= W = 4.8 mm, H = 2 mm Getting Started 6 Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 Block Diagram • LEDs (Wuerth Elektronik eiSos GmbH) – SMD Yellow 0805 – SMD Green 0805 For illustration of the I/O port definition of EASY 7071 Reference Board (Top Layer), see Figure 1. Table 1 shows LED definition of EASY 7071 Reference Board. Table 1 LED Definition LED Description Remark LED1 G0LED0 Controlled by LED0 of first XWAY™ PHY11G (PEF 7071) LED2 G0LED2 Controlled by LED2 of first XWAY™ PHY11G (PEF 7071) LED3 G1LED0 Controlled by LED0 of second XWAY™ PHY11G (PEF 7071) LED4 G1LED2 Controlled by LED2 of second XWAY™ PHY11G (PEF 7071) Getting Started 7 Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 Interface 3 Interface This chapter describes the interface and header pinouts of EASY 7071 Reference Board, Version 2.3.1. RGMII and SGMII Interfaces 3.1 In applications using the copper medium, the XWAY™ PHY11G is used to connect a 10/100/1000BASE-T capable MAC unit to a twisted-pair medium, such as a CAT5 cable infrastructure. The connection between MAC and PHY can be established using RGMII or SGMII. In this design, it uses the RGMII interface and 3.3 V. Controller with RGMII or SGMII support RGMII or SGMII 2.5 or 3.3 V Transformer RJ45 XWAY™ PHY11G (PEF 7071) 25 MHz LEDs Pin Strapping RGMII _interface .v sd Figure 3 RGMII Interface 3.2 Mini USB Device Connector (CON1) Mini USB device connector is used for connecting to USB Host or USB Hub. Figure 4 Mini USB Device Connector (Front View) Table 2 shows the pin definition of CON1. Table 2 Pin Definition of CON1 Pin Number Pin Name Pin Number Pin Name 1 VCC 2 D- 3 D+ 4 GND 5, 6, 7, 8 SHELL - - Getting Started 8 Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 Interface 3.3 Connector for 4 Pin UART Module J5 and J6 are connector for 4 pin UART module. 1 2 3 VDD Figure 5 LED0 4 GND Connector for 4 Pin UART Module Table 3 shows the pin definition of J5 and J6. Table 3 Pin Definition of J5 and J6 Pin Number Pin Name 1 Power 2 NC 3 LED0 of XWAY™ PHY11G (PEF 7071) 4 GND Getting Started 9 Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 BOM of EASY 7071 Reference Board 4 BOM of EASY 7071 Reference Board Table 4 & Table 5 shows the BOM of EASY 7071 Reference Board. Attention: The Bill of Material contains all components including options of the Lantiq Family Board. Lantiq's Customer Support team will assist to decide on optimized number of components based on the target application. Table 4 BOM Item Quantity Designator 1 21 C1, C40, C41, C43, C44, C50, C51, 100 nF C53, C54, C55, C58, C75, C76, C78, C79, C84, C85, C87, C88, C89, C92 2 4 C46, C47, C81, C82 3 5 Value Manufacturer TDK 330 pF C3, C27, C45, C80, C117 TDK 22 µF/1206 1) TDK 1) TDK TDK 4 9 C5, C39, C42, C52, C57, C74, C77, C86, C91 10 µF/0805 5 4 C6, C12, C19, C35 47 µF/12061) 6 17 C7, C8, C9, C10, C11, C15, C16, C17, 100 nF/0603 C18, C20, C21, C23, C25, C26, C28, C38, C116 7 4 R3, R4, R5, R6 1) 0 Ω/06031) 8 3 C29, C37, C60 1 nF/1808 9 2 C33, C48 20 pF TDK Yageo 1) Holy Stone Enterprise Walsin Technology 1) 10 1 C34 10 nF/0603 11 2 C36, C113 10 nF TDK 12 8 C64, C67, C72, C73, C99, C102, C107, C108 68 pF TDK 13 2 C65, C66 33 pF TDK 14 1 C109 1 nF/2 kV Yageo 15 1 CON1 Ordering Code: 65100516121 Mini-B USB Connecter Wuerth Elektronik eiSos GmbH 16 1 FB1 Ordering Code: 742792651 600 Ω Wuerth Elektronik eiSos GmbH 17 2 FB3, FB4 0 Ω/12061) Yageo 18 2 L1, L2 Ordering Code: 74279202 120 Ω/BEAD Wuerth Elektronik eiSos GmbH 19 2 L3, L4 Ordering Code: 74476604 4.7 µH Wuerth Elektronik eiSos GmbH 20 1 L5 Ordering Code: 74408941010 1 µH Wuerth Elektronik eiSos GmbH 21 2 LED1, LED3 Ordering Code: 150080YS75000 LED0805 YELLOW Wuerth Elektronik eiSos GmbH 22 3 LED2, LED4, LED5 Ordering Code: 150080VS75000 LED0805 GREEN Wuerth Elektronik eiSos GmbH Getting Started 10 TDK Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 BOM of EASY 7071 Reference Board Table 4 BOM (cont’d) Item Quantity Designator Value Manufacturer 23 2 R10, R13 33 Ω Yageo 24 1 Q2 2SB1386100R Rohm 25 6 R1, R22, R36, R40, R73, R77 10 kΩ Yageo 26 1 R7 10 Ω,1% Yageo 27 2 RP1, RP2 68 Ω Yageo 28 1 R9 75 Ω Yageo 29 1 R12 180 Ω Yageo 30 3 R14, R15, R35 1.5 kΩ Yageo 31 19 R23, R34, R37, R41, R42, R43, R46, 0 Ω R47, R48, R60, R64, R71, R78, R79, R80, R83, R84, R85, R97 Yageo 32 5 R118, R122, R126, R130, R135 330 Ω Yageo 33 2 R25, R55 10 kΩ Yageo 34 1 R27 12 kΩ,1% Yageo 35 4 R28, R32, R65, R69 0 Ω/08051) Yageo 36 2 R31, R68 5.1 Ω Yageo 37 2 R33, R70 1 kΩ Yageo 38 2 R39, R76 510 Ω Yageo 39 4 R44, R45, R81, R82 16 kΩ,1% Yageo 40 1 R49 1.78 kΩ,1% Yageo 41 4 R50, R52, R88, R89 11 kΩ,1% Yageo 42 8 R56, R57, R58, R59, R93, R94, R95, 75 R96 Yageo 43 1 R86 2.74 kΩ,1% Yageo 44 1 R99 499 kΩ Yageo 45 1 R103 470 kΩ,1% Yageo 46 1 R106 150 kΩ Yageo 47 6 R115, R16, R51, R54, R87, R91 150 Ω Yageo 48 1 R137 1 kΩ Yageo 49 1 U1 ATxmega16A4U-MH Atmel 50 1 U2 XWAY™ TANTOSLantiq 2G (VQFN Package) 51 2 U3, U4 XWAY™ PHY11G (PEF 7071) Lantiq 52 1 U5 ESD5V3U2U Infineon 53 1 U6 TLV62090 Texas Instruments 1) Imperial code for SMD dimensions. Getting Started 11 Revision 1.0, 2013-12-11 EASY 7071 Reference Board Version 2.3.1 Literature References Table 5 DIP Item Quantity Designator Value Manufacturer 57 1 J3 Ordering Code: 613 006 211 21 Header 2x3 Wuerth Elektronik eiSos GmbH 58 3 J4, J5, J6 Ordering Code: 613 004 111 21 Header 1X4 Wuerth Elektronik eiSos GmbH 59 1 C24 100 µF Teapo 60 2 J1, J2 Ordering Code: 615008143521 RJ45 Wuerth Elektronik eiSos GmbH 61 1 SW1 Ordering Code: 431256058716 Reset button Wuerth Elektronik eiSos GmbH 62 2 T1, T2 Ordering Code: 7490200136 7490200136 Wuerth Elektronik eiSos GmbH 63 1 Y3 25 MHz TXC Literature References [1] XWAY™ PHY11G (PEF 7071) Version 1.5 User’s Manual Hardware Description Revision 2.0, 2012-10-17 Getting Started 12 Revision 1.0, 2013-12-11 www.lantiq.com Published by Lantiq Deutschland GmbH