LED-Treiber - Katalogue

TECHNOLOGY
SHORT CIRCUIT
COMPACT
PWM DIMMING
EFFICIENCY
CONSTANT CURRENT
OUTDOOR APPLICATION
ACTIVE PFC
QUALITY
ALL-ROUND PROTECTION
LED POWER SUPPLIES
GOOD PERFORMANCE
STREET LIGHTING
DESIGN
PAIRUI POWER SUPPLIES
CONSTANT VOLTAGE
MTBF
SAFETY
UNIVERSAL INPUT
TEMPERATURE
FACTORY
SPECIFICATION
WARRANTY
0-10V DIMMING
INDOOR APPLICATION
NO MOQ LIMIT
LOW RIPPLE
EMC STANDARDS
LIFE TIME
Sales Office
#1518 Dexin Mansion, No. 545 Museum Road, Yangzhou City, Jiangsu, China 225009
E-mail: [email protected] Tel: +86 (514) 8279 1592
w w w. p a i r u i g r o u p . c o m
Factory Location
No. 286 People East Road, Renhe Town, Tianchang City, Anhui, China 239331
Tel: +86 (550) 7814 888
Fax: +86 (550) 7931 133
RoHS REACH
LED Power Supplies
PAIRUI Group Inc.
INDOOR LIGHTING
PAIRUI GROUP INC. is a vertically integrated group company focused on designing and manufacturing
of power supplies. The group consists of power supply manufacturers, and upstream manufacturers of
transformers, inductors, magnetic cores and plastic parts, all under the same ownership. Most important
benefits from the integration include cost reduction and flexibility. As a result, PAIRUI is able to offer
power supply products with very competitive price, and design unique products to fit the most demanding
needs. For more than 30 years cultivated in this industry, PAIRUI's goal is to be your trusted power
partner.
OUTDOOR LIGHTING
20~40W
8~40W
LZ SERIES
PAGE 2-7
LC SERIES
20~150W
10~50W
LX SERIES
PAGE 8-15
LE/LF SERIES
PAGE 16-23
LG/LGS SERIES
8~40W
LN SERIES
PAGE 24-29
PAGE 30-35
PAGE 52-67
LED POWER SUPPLIES
POWER CONVERTERS
DEDICATED POWER SOLUTIONS
100~150W
LGC SERIES
12~35W
LS SERIES
PAGE 40-51
30~250W
20~60W
LL SERIES
PAGE 36-39
PAGE 68-71
80~250W
LGE SERIES
PAGE 72-78
1
LZ SERIES
8~40W LED Driver with
Low Cost
MODEL NUMBER STRUCTURE
LZ
B
25 - C
350
R
Ripple
Blank = High Ripple
R = Low Ripple * Not available for 8/12W Model
Output Parameter
CC type: Output Current(mA)
CV type: Output Voltage(Vdc) * Not yet available in this series
Output Type
C = Constant current type
V = Constant voltage type * Not yet available in this series
Maximum Output Power (W)
Input Voltage Range
U = Universal(90~264VAC)
A = 115VAC(90-132VAC) * Not yet available in this series
B = 230VAC(180-264VAC)
Series Name
FEATURES
3 Year Warranty
Constant Current Output
Active Power Factor Correction, Class II Power
Universal Input Voltage and High Input Voltage Selectable
Short Circuit and Over Voltage Protections
Safety Standards: Design Refer to EN61347-1, EN61347-2-13
EMC Standards: Compliance to EN55015, EN61000-3-2,
EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
2
APPLICATIONS
Indoor Lighting
Spot Lighting
Recessed Lighting
SERIES OVERVIEW
Cabinet Lighting
SERIES
VIN
OUTPUT (CC)
CASE
Down Lighting
LZ[ ]8-C
90-264VAC/180-264VAC
240, 350, 500, 700mA
95.5 x 32.5 x 21.5 mm
LZB12-C
180-264VAC
240, 350, 500, 700mA
95.5 x 32.5 x 21.5 mm
LZ[ ]18-C
90-264VAC/180-264VAC
350, 500, 700, 1050mA
130 x 42 x 24.5 mm
LZ[ ]25-C
90-264VAC/180-264VAC
350, 500, 700, 1050mA
130 x 42 x 24.5 mm
LZ[ ]40-C
90-264VAC/180-264VAC
350, 500, 700, 1050mA
137.5 x 45 x 28.5 mm
SAFETY APPROVAL
3
SPECIFICATIONS
8~40W LED Driver with Built-in Active PFC
LZ SERIES
LZ SERIES
8W/12W
FEATURES
FEATURES
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
Constant Current
Constant Current
MODELS
SPECIFICATIONS
MODELS
Model
Output
TOL.
RIPPLE
EFF(typ.)
Model
Output
TOL.
RIPPLE
EFF(typ.)
Model
Output
TOL.
RIPPLE
EFF(typ.)
Model
Output
TOL.
RIPPLE
EFF(typ.)
LZ[ ]8-C240
240mA (23-33V)
±5%
50%
80%
LZB12-C240
240mA (25-50V)
±5%
50%
80%
LZ[ ]18-C350
350mA (26-52V)
±5%
50%
85%
LZ[ ]18-C350R
350mA (26-52V)
±5%
5%
85%
LZ[ ]8-C350
350mA (16-23V)
±5%
50%
80%
LZB12-C350
350mA (18-36V)
±5%
50%
80%
LZ[ ]18-C500
500mA (25-36V)
±5%
50%
85%
LZ[ ]18-C500R
500mA (25-36V)
±5%
5%
85%
LZ[ ]8-C500
500mA(11-16V)
±5%
50%
80%
LZB12-C500
500mA (17-24V)
±5%
50%
80%
LZ[ ]18-C700
700mA (17-34V)
±5%
50%
85%
LZ[ ]18-C700R
700mA (17-34V)
±5%
5%
85%
LZ[ ]8-C700
700mA (9-12V)
±5%
50%
80%
LZB12-C700
700mA (9-18V)
±5%
50%
80%
LZ[ ]18-C1050
1050mA (13-26V)
±5%
50%
85%
LZ[ ]18-C1050R 1050mA (13-26V)
±5%
5%
85%
* [ ]= U or B, U(90~264VAC), B(180~264VAC)
* [ ]= U or B, U(90~264VAC), B(180~264VAC)
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
* [ ]= U or B, U(90~264VAC), B(180~264VAC)
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
8W: 90-264VAC/180-264VAC, 47~63Hz; 12W: 180-264VAC, 47-63Hz
VOLTAGE RANGE, FREQUENCY
90-264VAC/180-264VAC, 47~63Hz
POWER FACTOR (Typ.)
8W: 0.9/220VAC; 12W: 0.95/220VAC (70%~100% full load)
INPUT CURRENT (Typ.)
8W: 0.1A/230VAC; 12W: 0.15A/230VAC
POWER FACTOR (Typ.)
0.95/220VAC (70%~100% full load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.15A/230VAC
8W: COLD START, 20A/230VAC; 12W: COLD START, 35A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 35A/230VAC
LINE REGULATION
5%
LINE REGULATION
5%
LOAD REGULATION
5%
LOAD REGULATION
5%
SETUP, RISE TIME
2S at full load (cold start, power on)
SETUP, RISE TIME
2S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
MECHANICAL SPECIFICATION
4
18W
8~40W LED Driver with Built-in Active PFC
LZ SERIES
LZ SERIES
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 75g
Weight: 115g
5
SPECIFICATIONS
8~40W LED Driver with Built-in Active PFC
LZ SERIES
LZ SERIES
25W
FEATURES
FEATURES
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
Constant Current
Constant Current
MODELS
SPECIFICATIONS
MODELS
Model
Output
TOL.
RIPPLE
EFF(typ.)
Model
Output
TOL.
RIPPLE
EFF(typ.)
Model
Output
TOL.
RIPPLE
EFF(typ.)
Model
Output
TOL.
RIPPLE
EFF(typ.)
LZ[ ]25-C350
350mA (43-72V)
±5%
50%
85%
LZ[ ]25-C350R
350mA (43-72V)
±5%
5%
85%
LZ[ ]40-C350
350mA (66-110V)
±5%
50%
85%
LZ[ ]40-C350R
350mA (66-110V)
±5%
5%
85%
LZ[ ]25-C500
500mA (35-50V)
±5%
50%
85%
LZ[ ]25-C500R
500mA (35-50V)
±5%
5%
85%
LZ[ ]40-C500
500mA (56-80V)
±5%
50%
85%
LZ[ ]40-C500R
500mA (56-80V)
±5%
5%
85%
LZ[ ]25-C700
700mA (22-36V)
±5%
50%
85%
LZ[ ]25-C700R
700mA (22-36V)
±5%
5%
85%
LZ[ ]40-C700
700mA (34-57V)
±5%
50%
85%
LZ[ ]40-C700R
700mA (34-57V)
±5%
5%
85%
LZ[ ]25-C1050
1050mA (15-24V)
±5%
50%
85%
LZ[ ]25-C1050R 1050mA (15-24V)
±5%
5%
85%
LZ[ ]40-C1050
1050mA (23-39V)
±5%
50%
85%
LZ[ ]40-C1050R 1050mA (23-39V)
±5%
5%
85%
* [ ]= U or B, U(90~264VAC), B(180~264VAC)
* [ ]= U or B, U(90~264VAC), B(180~264VAC)
* [ ]= U or B, U(90~264VAC), B(180~264VAC)
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
* [ ]= U or B, U(90~264VAC), B(180~264VAC)
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC/180-264VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-264VAC/180-264VAC, 47~63Hz
POWER FACTOR (Typ.)
0.95/220VAC (70%~100% full load)
INPUT CURRENT (Typ.)
0.15A/230VAC
POWER FACTOR (Typ.)
0.95/220VAC (70%~100% full load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.25A/230VAC
COLD START, 35A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 35A/230VAC
LINE REGULATION
5%
LINE REGULATION
5%
LOAD REGULATION
5%
LOAD REGULATION
5%
SETUP, RISE TIME
2S at full load (cold start, power on)
SETUP, RISE TIME
2S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=200~240VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=200~240VAC
MECHANICAL SPECIFICATION
6
40W
8~40W LED Driver with Built-in Active PFC
LZ SERIES
LZ SERIES
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 120g
Weight: 160g
7
LX SERIES
10~50W LED Driver with
Built-in PFC
MODEL NUMBER STRUCTURE
LX
U
30 - C
350
D
Dimming Option
Blank = Without dimming
D = With 0~10V dimming
Output Parameter
CC type: Output Current(mA)
CV type: Output Voltage(Vdc) * Not yet available in this series
Output Type
C = Constant current type
V = Constant voltage type * Not yet available in this series
Maximum Output Power (W)
Input Voltage Range
U = Universal (90~264VAC)
Series Name
FEATURES
3 Year Warranty
Constant Current Output
Active Power Factor Correction, Class II Power
Universal Input Voltage 90~264Vac
Short Circuit and Over Voltage Protections
Safety Standards: Design refer to EN61347-1, EN61347-2-13
EMC Standards: Compliance to EN55015, EN61000-3-2,
EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547
8
APPLICATIONS
Indoor Lighting
SERIES OVERVIEW
Spot Lighting
SERIES
VIN
OUTPUT (CC)
CASE
LXU10-C(D)
90~264VAC
240, 350, 700mA
70 x 43 x 30 mm
LXU15-C(D)
90~264VAC
240, 350, 700mA
70 x 43 x 30 mm
LXU30-C(D)
90~264VAC
350, 700, 1050mA
97 x 43 x 30 mm
LXU40-C(D)
90~264VAC
350, 700, 1050mA
122 x 43 x 30 mm
LXU45-C(D)
90~264VAC
350, 700, 1050mA
122 x 43 x 30 mm
LXU50-C(D)
90~264VAC
350, 700, 1050mA
122 x 43 x 30 mm
Recessed Lighting
Cabinet Lighting
Down Lighting
SAFETY APPROVAL
9
SPECIFICATIONS
10~50W LED Driver with Built-in PFC
LX SERIES
LX SERIES
10W
FEATURES
FEATURES
> 3 Year Warranty
> Constant Current Output
> Class II Power
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
> 3 Year Warranty
> Constant Current Output
> Class II Power
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
Constant Current
Constant Current
MODELS
SPECIFICATIONS
MODELS
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
LXU10-C240
240mA (25-42V)
±5%
40%
85%
LXU10-C240D
240mA (25-42V)
±5%
40%
85%
LXU15-C240
240mA (37-62V)
±5%
40%
85%
LXU15-C240D
240mA (37-62V)
±5%
40%
85%
LXU10-C350
350mA (17-29V)
±5%
40%
85%
LXU10-C350D
350mA (17-29V)
±5%
40%
85%
LXU15-C350
350mA (26-42V)
±5%
40%
85%
LXU15-C350D
350mA (26-42V)
±5%
40%
85%
LXU10-C700
700mA (9-14V)
±5%
40%
85%
LXU10-C700D
700mA (9-14V)
±5%
40%
85%
LXU15-C700
700mA (13-21V)
±5%
40%
85%
LXU15-C700D
700mA (13-21V)
±5%
40%
85%
* Above models which have suffix “D” are all with 0-10V dimming
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
* Above models which have suffix “D” are all with 0-10V dimming
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
POWER FACTOR
0.9/230VAC (70%~100% full load)
INPUT CURRENT
0.1A/230VAC
POWER FACTOR
0.9/230VAC (70%~100% full load)
INPUT CURRENT
LEAKAGE CURRENT
0.15A/230VAC
0.75mA/230VAC
LEAKAGE CURRENT
0.75mA/230VAC
INRUSH CURRENT
COLD START, 15A/230VAC at full load
INRUSH CURRENT
COLD START, 15A/230VAC at full load
LINE REGULATION
±3%
LINE REGULATION
±3%
LOAD REGULATION
±3%
LOAD REGULATION
±3%
SETUP, RISE TIME
1.5S at full load (cold start, power on)
SETUP, RISE TIME
1.5S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing
OPERATING
Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
MECHANICAL SPECIFICATION
10
15W
10~50W LED Driver with Built-in PFC
LX SERIES
LX SERIES
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 130g
Weight: 130g
11
SPECIFICATIONS
10~50W LED Driver with Built-in PFC
LX SERIES
LX SERIES
30W
FEATURES
FEATURES
> 3 Year Warranty
> Constant Current Output
> Class II Power
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
> 3 Year Warranty
> Constant Current Output
> Class II Power
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
Constant Current
Constant Current
MODELS
SPECIFICATIONS
MODELS
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
LXU30-C350
350mA (60-86V)
±5%
40%
89%
LXU30-C350D
350mA (60-86V)
±5%
40%
89%
LXU40-C350
350mA (80-114V)
±5%
40%
89%
LXU40-C350D
350mA (80-114V)
±5%
40%
89%
LXU30-C700
700mA (30-43V)
±5%
40%
88%
LXU30-C700D
700mA (30-43V)
±5%
40%
88%
LXU40-C700
700mA (40-58V)
±5%
40%
88%
LXU40-C700D
700mA (40-58V)
±5%
40%
88%
LXU30-C1050
1050mA (20-29V)
±5%
40%
86%
LXU30-C1050D
1050mA (20-29V)
±5%
40%
86%
LXU40-C1050
1050mA (27-38V)
±5%
40%
86%
LXU40-C1050D
1050mA (27-38V)
±5%
40%
86%
* Above models which have suffix “D” are all with 0-10V dimming
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
* Above models which have suffix “D” are all with 0-10V dimming
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
POWER FACTOR
0.9/230VAC (70%~100% full load)
INPUT CURRENT
0.2A/230VAC
POWER FACTOR
0.92/230VAC (70%~100% full load)
INPUT CURRENT
LEAKAGE CURRENT
0.3A/230VAC
0.75mA/230VAC
LEAKAGE CURRENT
0.75mA/230VAC
INRUSH CURRENT
COLD START, 25A/230VAC at full load
INRUSH CURRENT
COLD START, 35A/230VAC at full load
LINE REGULATION
±3%
LINE REGULATION
±3%
LOAD REGULATION
±3%
LOAD REGULATION
±3%
SETUP, RISE TIME
1.5S at full load (cold start, power on)
SETUP, RISE TIME
1.5S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing
OPERATING
Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
MECHANICAL SPECIFICATION
12
40W
10~50W LED Driver with Built-in PFC
LX SERIES
LX SERIES
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 250g
Weight: 270g
13
SPECIFICATIONS
10~50W LED Driver with Built-in PFC
LX SERIES
LX SERIES
45W
FEATURES
FEATURES
> 3 Year Warranty
> Constant Current Output
> Class II Power
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
> 3 Year Warranty
> Constant Current Output
> Class II Power
> Active Power Factor Correction
> Short Circuit, Over Voltage Protections
Constant Current
Constant Current
MODELS
SPECIFICATIONS
MODELS
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
Model
Output
TOL.
Ripple
EFF(typ.)
LXU45-C350
350mA (90-129V)
±5%
40%
89%
LXU45-C350D
350mA (90-129V)
±5%
40%
89%
LXU50-C350
350mA (100-142V)
±5%
40%
89%
LXU50-C350D
350mA (100-142V)
±5%
40%
89%
LXU45-C700
700mA (46-65V)
±5%
40%
88%
LXU45-C700D
700mA (46-65V)
±5%
40%
88%
LXU50-C700
700mA (50-71V)
±5%
40%
88%
LXU50-C700D
700mA (50-71V)
±5%
40%
88%
LXU45-C1050
1050mA (30-43V)
±5%
40%
86%
LXU45-C1050D
1050mA (30-43V)
±5%
40%
86%
LXU50-C1050
1050mA (33-48V)
±5%
40%
86%
LXU50-C1050D
1050mA (33-48V)
±5%
40%
86%
* Above models which have suffix “D” are all with 0-10V dimming
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
* Above models are all with 0-10V dimming
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
POWER FACTOR
0.92/230VAC (70%~100% full load)
INPUT CURRENT
0.4A/230VAC
POWER FACTOR
0.92/230VAC (70%~100% full load)
INPUT CURRENT
LEAKAGE CURRENT
0.45A/230VAC
0.75mA/230VAC
LEAKAGE CURRENT
0.75mA/230VAC
INRUSH CURRENT
COLD START, 35A/230VAC at full load
INRUSH CURRENT
COLD START, 35A/230VAC at full load
LINE REGULATION
±3%
LINE REGULATION
±3%
LOAD REGULATION
±3%
LOAD REGULATION
±3%
SETUP, RISE TIME
1.5S at full load (cold start, power on)
SETUP, RISE TIME
1.5S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing
OPERATING
Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
MECHANICAL SPECIFICATION
14
50W
10~50W LED Driver with Built-in PFC
LX SERIES
LX SERIES
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 270g
Weight: 300g
15
LL SERIES
20~60W Isolated LED Driver
for Commercial LED Lighting
MODEL NUMBER STRUCTURE
LL M
U
20 - C
500
A
Dimming Option
Blank = No dimming
A = 3 in 1 dimming(0~10V, PWM, Resistor)
Output Parameter
CC type: Output Current(mA)
CV type: Output Voltage(Vdc) * Not yet available in this series
Output Type
C = Constant current type
V = Constant voltage type * Not yet available in this series
Maximum Output Power (W)
Input Voltage Range
U = Universal(90-305VAC)
Output Voltage Range
M = 27-40VDC
N = 35-55VDC
Series Name
FEATURES
3 Year Warranty
Constant Current Output
Active Power Factor Correction
3 in 1 Dimming(0~10V, PWM, Resistor)
Can be Used for Lighting Equipment in Protection Class I and II
Short Circuit and Over Voltage Protections
APPLICATIONS
Indoor Lighting
Strip Lighting
Wall Lighting
SERIES OVERVIEW
Cabinet Lighting
SERIES
VIN
OUTPUT (CC)
CASE
Tri-Proof Lighting
LL[ ]20-C (A)
90~305VAC
300, 350, 400, 450, 500, 550mA
245 x 30 x 21 mm
SAFETY APPROVAL
LL[ ]40-C (A)
90~305VAC
500, 600, 700, 750, 800, 900, 950, 1000mA
285 x30 x 21 mm
LL[ ]60-C (A)
90~305VAC
1200, 1300, 1400, 1500, 1550mA
355 x30 x 21 mm
Safety Standards: Design Refer to EN61347-1, EN61347-2-13
EMC Standards: Compliance to EN55015, EN61000-3-2,
EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
16
17
LL SERIES
LL SERIES
20W
SPECIFICATIONS
20~60W Isolated LED Driver for Commercial LED Lighting
FEATURES
> Active Power Factor Correction
> Can be Used for Lighting Equipment in
Protection Class I and II
> No Flickering
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Short Circuit, Over Voltage
Protections
Constant Current
> 3 in 1 Dimming(0~10V, PWM, Resistor)
> Active Power Factor Correction
> Can be Used for Lighting Equipment in
Protection Class I and II
Constant Current
MODELS
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
LLMU20-C350
350mA (27-40V)
±5%
14W
83%
LLNU20-C300
300mA(35-55V)
±5%
16.5W
84%
LLMU20-C350A
350mA(27-40V)
±5%
14W
84%
LLNU20-C300A
300mA(35-55V)
±5%
16.5W
85%
LLMU20-C400
400mA (27-40V)
±5%
16W
85%
LLNU20-C350
350mA(35-55V)
±5%
19.25W
86%
LLMU20-C400A
400mA(27-40V)
±5%
16W
84%
LLNU20-C350A
350mA(35-55V)
±5%
19.25W
85%
LLMU20-C450
450mA (27-40V)
±5%
18W
86%
LLNU20-C400
400mA(35-55V)
±5%
22W
86%
LLMU20-C450A
450mA(27-40V)
±5%
18W
86%
LLNU20-C400A
400mA(35-55V)
±5%
22W
86%
LLMU20-C500
500mA (27-40V)
±5%
20W
86%
LLMU20-C500A
500mA(27-40V)
±5%
20W
86%
LLMU20-C550
550mA (27-40V)
±5%
22W
86%
LLMU20-C550A
550mA(27-40V)
±5%
22W
86%
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
LL SERIES
MODELS
LL SERIES
SPECIFICATIONS
FEATURES
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Short Circuit, Over Voltage
Protections
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90~305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90~305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.95/230VAC (70%~100% full load)
INPUT CURRENT (Typ.)
0.4A/230VAC
POWER FACTOR (Typ.)
0.95/230VAC (70%~100% full load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.4A/230VAC
COLD START, 60A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 60A/230VAC
LINE REGULATION
±5%
LINE REGULATION
±5%
LOAD REGULATION
±5%
LOAD REGULATION
±5%
SETUP, RISE TIME
≤1S at full load (cold start, power on)
SETUP, RISE TIME
≤1S at full load (cold start, power on)
RIPPLE
<1V
RIPPLE
<4V
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
110-130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing
OPERATING
Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
MECHANICAL SPECIFICATION
18
20W
20~60W Isolated LED Driver for Commercial LED Lighting
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 140g
Weight: 145g
19
LL SERIES
LL SERIES
40W
SPECIFICATIONS
20~60W Isolated LED Driver for Commercial LED Lighting
FEATURES
> Active Power Factor Correction
> Can be Used for Lighting Equipment in
Protection Class I and II
> No Flickering
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Short Circuit, Over Voltage
Protections
Constant Current
> 3 in 1 Dimming(0~10V, PWM, Resistor)
> Active Power Factor Correction
> Can be Used for Lighting Equipment in
Protection Class I and II
Constant Current
MODELS
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
LLMU40-C600
600mA (27-40V)
±5%
24W
85%
LLMU40-C1000
1000mA (27-40V)
±5%
40W
85%
LLMU40-C600A
600mA (27-40V)
±5%
24W
85%
LLMU40-C1000A
1000mA (27-40V)
±5%
40W
86%
LLMU40-C700
700mA (27-40V)
±5%
28W
85%
LLNU40-C500
500mA (35-55V)
±5%
27.5W
85%
LLMU40-C700A
700mA (27-40V)
±5%
28W
85%
LLNU40-C500A
500mA (35-55V)
±5%
27.5W
86%
LLMU40-C800
800mA (27-40V)
±5%
32W
85%
LLNU40-C600
600mA (35-55V)
±5%
33W
85%
LLMU40-C800A
800mA (27-40V)
±5%
32W
85%
LLNU40-C600A
600mA (35-55V)
±5%
33W
86%
LLMU40-C900
900mA (27-40V)
±5%
36W
85%
LLNU40-C750
750mA (35-55V)
±5%
41.25W
85%
LLMU40-C900A
900mA (27-40V)
±5%
36W
85%
LLNU40-C750A
750mA (35-55V)
±5%
41.25W
86%
LLMU40-C950
950mA (27-40V)
±5%
38W
85%
LLMU40-C950A
950mA (27-40V)
±5%
38W
86%
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
LL SERIES
MODELS
LL SERIES
SPECIFICATIONS
FEATURES
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Short Circuit, Over Voltage
Protections
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90~305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90~305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.94/230VAC (70%~100% full load)
INPUT CURRENT (Typ.)
0.7A/230VAC
POWER FACTOR (Typ.)
0.94/230VAC (70%~100% full load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.4A/230VAC
COLD START, 60A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 60A/230VAC
LINE REGULATION
±5%
LINE REGULATION
±5%
LOAD REGULATION
±5%
LOAD REGULATION
±5%
SETUP, RISE TIME
≤1S at full load (cold start, power on)
SETUP, RISE TIME
≤1S at full load (cold start, power on)
RIPPLE
<2V
RIPPLE
<4V
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
110-130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing
OPERATING
Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
MECHANICAL SPECIFICATION
20
40W
20~60W Isolated LED Driver for Commercial LED Lighting
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 195g
Weight: 200g
21
LL SERIES
20~60W Isolated LED Driver for Commercial LED Lighting
LL SERIES
60W
SPECIFICATIONS
FEATURES
> Active Power Factor Correction
> Can be Used for Lighting Equipment in
Protection Class I and II
> No Flickering
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Short Circuit, Over Voltage
Protections
Constant Current
MODELS
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
LLMU60-C1200
1200mA (27-40V)
±5%
48W
86%
LLMU60-C1200A
1200mA (27-40V)
±5%
48W
86%
LLMU60-C1300
1300mA (27-40V)
±5%
52W
86%
LLMU60-C1300A
1300mA (27-40V)
±5%
52W
86%
LLMU60-C1400
1400mA (27-40V)
±5%
56W
86%
LLMU60-C1400A
1400mA (27-40V)
±5%
56W
86%
LLMU60-C1500
1500mA (27-40V)
±5%
60W
86%
LLMU60-C1500A
1500mA (27-40V)
±5%
60W
86%
LLMU60-C1550
1550mA (27-40V)
±5%
62W
86%
LLMU60-C1550A
1550mA (27-40V)
±5%
62W
86%
CHARACTERISTICS
PROTECTION
ENVIRONMENT
SAFETY
LL SERIES
LL SERIES
> 3 in 1 Dimming(0~10V, PWM, Resistor)
> Active Power Factor Correction
> Can be Used for Lighting Equipment in
Protection Class I and II
Model
OUTPUT
SPECIFICATIONS
Constant Current
MODELS
INPUT
60W
FEATURES
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Short Circuit, Over Voltage
Protections
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90~305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90~305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.92/230VAC (70%~100% full load)
INPUT CURRENT (Typ.)
0.9A/230VAC
POWER FACTOR (Typ.)
0.92/230VAC (70%~100% full load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.9A/230VAC
COLD START, 60A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 60A/230VAC
LINE REGULATION
±5%
LINE REGULATION
±5%
LOAD REGULATION
±5%
LOAD REGULATION
±5%
SETUP, RISE TIME
≤1S at full load (cold start, power on)
SETUP, RISE TIME
≤1S at full load (cold start, power on)
RIPPLE
<1V
RIPPLE
<4V
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
110-130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing
OPERATING
Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
MECHANICAL SPECIFICATION
22
20~60W Isolated LED Driver for Commercial LED Lighting
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 300g
Weight: 305g
23
LN SERIES
8~40W LED Driver with Built-in
Active PFC
MODEL NUMBER STRUCTURE
LN
U
12 - C
350
Output Parameter
CC type: Output Current(mA)
CV type: Output Voltage(Vdc) * Not yet available in this series
Output Type
C = Constant current type
V = Constant voltage type * Not yet available in this series
Maximum Output Power (W)
Input Voltage Range
U = Universal(90~305VAC)
Series Name
FEATURES
3 Year Warranty
High Efficiency up to 91%
Active Power Factor Correction
Universal Input Range: 90~305VAC
Short Circuit and Over Voltage Protections
Isolation Voltage: 3.85KVAC
APPLICATIONS
Indoor Lighting
Spot Lighting
Recessed Lighting
Cabinet Lighting
Down Lighting
Certified to TUV, CE
Safety Standards: UL8750, EN61347-1, EN61347-2-13
EMC Standards: EN55015, FCC Part15 Class B, EN61000-3-2,
EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
24
SAFETY APPROVAL
SERIES OVERVIEW
SERIES
VIN
OUTPUT (CC)
CASE
LNU8-C
90~305VAC
240, 350mA
80 x 31.8 x 24.2 mm
LNU12-C
90~305VAC
240, 350, 530, 700mA
88.8 x 44.8 x 30.5 mm
LNU18-C
90~305VAC
350, 530, 700mA
109.8 x 44.8 x 30.5 mm
LNU25-C
90~305VAC
350, 530, 700, 1050mA
109.8 x 44.8 x 30.5 mm
LNU40-C
90~305VAC
350, 530, 700, 1050, 1400mA
134.8 x 44.8 x 30.5 mm
25
LN SERIES
LN SERIES
8W
SPECIFICATIONS
8~40W LED Driver with Built-in Active PFC
FEATURES
FEATURES
> 3 Year Warranty
> Certified to TUV, CE
> Active Power Factor Correction
> Universal Input Range: 90~305VAC
> Short Circuit and Over Voltage Protections
> 3 Year Warranty
> Certified to TUV, CE
> Active Power Factor Correction
> Universal Input Range: 90~305VAC
> High Efficiency up to 85%
> Short Circuit and Over Voltage Protections
Constant Current
Constant Current
MODELS
Model
Output
TOL.
VNO-LOAD
EFF.
Model
Output
TOL.
VNO-LOAD
EFF.
LNU8-C240
240mA (18~34V)
±5%
40V
80%
LNU12-C240
240mA (25~50V)
±5%
60V
85%
LNU8-C350
350mA (14~23V)
±5%
28V
79%
LNU12-C350
350mA (18~36V)
±5%
45V
84%
LNU12-C530
530mA (12~24V)
±5%
32V
83%
LNU12-C700
700mA (9~18V)
±5%
25V
83%
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
Model
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.85/220VAC(70%~100% full load)
INPUT CURRENT (Typ.)
0.06A/230VAC(full load)
POWER FACTOR (Typ.)
0.9/220VAC(70%~100% full load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.1A/230VAC(full load)
COLD START, 35A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 35A/230VAC
LINE REGULATION
±3%
LINE REGULATION
±3%
LOAD REGULATION
±3%
LOAD REGULATION
±3%
SETUP, RISE TIME
≤2S(cold start, power on)
SETUP, RISE TIME
≤2S (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
120% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
120% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
INPUT
OUTPUT
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. MIL-HDBK-217F (25°C)
SAFETY
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. MIL-HDBK-217F (25°C)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~277VAC
MECHANICAL SPECIFICATION
AC INPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~277VAC
26
SPECIFICATIONS
LN SERIES
LN SERIES
MODELS
12W
8~40W LED Driver with Built-in Active PFC
MECHANICAL SPECIFICATION
DC OUTPUT
Dimensions in mm
Dimensions in mm
Weight: 45g
Weight: 80g
AC INPUT
DC OUTPUT
27
LN SERIES
LN SERIES
18/25W
SPECIFICATIONS
8~40W LED Driver with Built-in Active PFC
FEATURES
FEATURES
> 3 Year Warranty
> Certified to TUV, CE
> Active Power Factor Correction
> Universal Input Range: 90~305VAC
> High Efficiency up to 88%
> Short Circuit and Over Voltage Protections
> 3 Year Warranty
> Certified to TUV, CE
> Active Power Factor Correction
> Universal Input Range: 90~305VAC
> High Efficiency up to 91%
> Short Circuit and Over Voltage Protections
Constant Current
Constant Current
SPECIFICATIONS
MODELS
Model
Output
TOL.
VNO-LOAD
EFF.
Model
Output
TOL.
VNO-LOAD
EFF.
Model
Output
TOL.
VNO-LOAD
EFF.
LNU18-C350
350mA (26~52V)
±5%
60V
88%
LNU25-C350
350mA (36~72V)
±5%
90V
89%
LNU40-C350
350mA (57~114V)
±5%
135V
91%
LNU18-C530
530mA (17~34V)
±5%
45V
87%
LNU25-C530
530mA (24~48V)
±5%
58V
88%
LNU40-C530
530mA (38~76V)
±5%
90V
91%
LNU18-C700
700mA (13~26V)
±5%
32V
87%
LNU25-C700
700mA (18~36V)
±5%
45V
88%
LNU40-C700
700mA (28~57V)
±5%
70V
90%
LNU25-C1050
1050mA (12~24V)
±5%
32V
87%
LNU40-C1050
1050mA (19~38V)
±5%
48V
90%
LNU40-C1400
1400mA (14~29V)
±5%
40V
89%
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
LN SERIES
LN SERIES
MODELS
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.9/220VAC(70%~100% full load)
INPUT CURRENT (Typ.)
18W: 0.15A/230VAC; 25W: 0.2A/230VAC(full load)
POWER FACTOR (Typ.)
0.95/220VAC(70%~100% full load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.25A/230VAC(full load)
COLD START, 35A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 35A/230VAC
LINE REGULATION
±3%
LINE REGULATION
±5%
LOAD REGULATION
±3%
LOAD REGULATION
±5%
SETUP, RISE TIME
≤2S (cold start, power on)
SETUP, RISE TIME
≤2S (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
120% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
120% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
INPUT
OUTPUT
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. MIL-HDBK-217F (25°C)
SAFETY
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. MIL-HDBK-217F (25°C)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~277VAC
MECHANICAL SPECIFICATION
AC INPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~277VAC
28
40W
8~40W LED Driver with Built-in Active PFC
MECHANICAL SPECIFICATION
DC OUTPUT
Dimensions in mm
Dimensions in mm
Weight: 110g
Weight: 153g
AC INPUT
DC OUTPUT
29
LS SERIES
12~35W IP30 Rated LED
Power Supplies
MODEL NUMBER STRUCTURE
LS
U
12 - C
350
Output Parameter
CC type: Output Current(mA)
CV type: Output Voltage(Vdc)
Output Type
C = Constant current type
V = Constant voltage type
Maximum Output Power (W)
Input Voltage Range
U = Universal (90~264VAC)
Series Name
FEATURES
2 Year Warranty
Constant Current and Constant Voltage Output
IP30 Rated for Indoor Lighting
Class II, no FG
100% Burn-in Test
Certified to CE
APPLICATIONS
Indoor Lighting
Spot Lighting
Recessed Lighting
Cabinet Lighting
Down Lighting
Safety Standards: Design Refer to UL8750, EN61347-1,
EN61347-2-13
EMC Standards: Compliance to EN55015, FCC Part15 Class B, EN
61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
30
SAFETY APPROVAL
SERIES OVERVIEW
SERIES
VIN
OUTPUT (CC or CV)
CASE
LS_12-C/V
90~264VAC
350, 700mA
5, 12, 15, 24Vdc
77 x 40 x 30 mm
LS_16-C/V
90~264VAC
350, 700mA
5, 12, 15, 24Vdc
77 x 40 x 30 mm
LS_25-C/V
90~264VAC
350, 500, 700, 1050mA
5, 12, 15, 24, 36Vdc
84 x 57 x 29.5 mm
LS_35-C/V
90~264VAC
350, 500, 700, 1050mA
5, 12, 15, 24, 36Vdc
84 x 57 x 29.5 mm
31
LS SERIES
SPECIFICATIONS
12~35W IP30 Rated LED Power Supplies
FEATURES
> 2 Year Warranty
> IP30 Rated for Indoor Lighting
> Class II, No FG
> 100% Burn-in Test
> Cooling by Free Air Convection
> Short Circuit Protection
> 2 Year Warranty
> IP30 Rated for Indoor Lighting
> Class II, No FG
> 100% Burn-in Test
> Cooling by Free Air Convection
> Short Circuit Protection
Constant Voltage
MODELS
SPECIFICATIONS
Constant Current
MODELS
Constant Voltage
MODELS
MODELS
Model
Output
TOL.
RIPPLE
EFF.
Model
Output
TOL.
RIPPLE
EFF.
Model
Output
TOL.
RIPPLE
EFF.
Model
Output
TOL.
RIPPLE
EFF.
LSU12-C350
350mA (22~36V)
±5%
300mAp-p
78%
LSU12-V5
5V (0~2A)
±5%
100mVp-p
75%
LSU16-C350
350mA (29~48V)
±5%
300mAp-p
78%
LSU16-V5
5V (0~2.6A)
±5%
100mVp-p
75%
LSU12-C700
700mA (11~18V)
±5%
250mAp-p
80%
LSU12-V12
12V (0~1A)
±5%
120mVp-p
79%
LSU16-C700
700mA (15~24V)
±5%
250mAp-p
81%
LSU16-V12
12V (0~1.25A)
±5%
120mVp-p
80%
LSU12-V15
15V (0~0.8A)
±5%
120mVp-p
78%
LSU16-V15
15V (0~1A)
±5%
120mVp-p
80%
LSU12-V24
24V (0~0.5A)
±5%
150mVp-p
81%
LSU16-V24
24V (0~0.67A)
±5%
150mVp-p
82%
INPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC/120-370VDC, 47~63Hz
INPUT CURRENT (Typ.)
0.35A/115VAC, 0.2A/230VAC(full load)
INRUSH CURRENT (Typ.)
COLD START, 70A/230VAC
LINE REGULATION
±1%
LOAD REGULATION
±3%
SETUP, RISE TIME (Typ.)
LS SERIES
CHARACTERISTICS
OUTPUT
VOLTAGE RANGE, FREQUENCY
90-264VAC/120-370VDC, 47~63Hz
INPUT CURRENT (Typ.)
0.5A/115VAC, 0.3A/230VAC(full load)
INRUSH CURRENT (Typ.)
COLD START, 45A/230VAC(CC); 50A/230VAC(CV)
LINE REGULATION
±1%
LOAD REGULATION
±3%
3000ms, 180ms/230VAC(CC); 1500ms, 30ms/230VAC(CV) at full load
SETUP, RISE TIME (Typ.)
3000ms, 200ms/230VAC(CC); 1500ms, 30ms/230VAC(CV) at full load
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OPERATING
Temperature -25°C~+70°C(derating required), Humidity 20 ~ 90% RH non-condensing
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
TEMPERATURE COEFFICIENT
±0.2%/°C (0-50°C)
TEMPERATURE COEFFICIENT
±0.2%/°C (0-50°C)
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. MIL-HDBK-217F (25°C)
MTBF
400K hours min. MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=115VAC/230VAC
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=115VAC/230VAC
MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 105g
Weight: 105g
77
77
DC
OUT
RED
BLACK
150±10
BLUE
BROWN
18 AWG
RED
BLACK
150±10
AC
IN
BLUE
BROWN
18 AWG
AC
IN
77
18 AWG
29
29
77
18 AWG
150±10
18 AWG
40
150±10
18 AWG
40
DC
OUT
32
16W
12~35W IP30 Rated LED Power Supplies
FEATURES
Constant Current
LS SERIES
LS SERIES
12W
18 AWG
18 AWG
33
LS SERIES
SPECIFICATIONS
12~35W IP30 Rated LED Power Supplies
FEATURES
> 2 Year Warranty
> IP30 Rated for Indoor Lighting
> Class II, No FG
> 100% Burn-in Test
> Cooling by Free Air Convection
> 2 Year Warranty
> IP30 Rated for Indoor Lighting
> Class II, No FG
> 100% Burn-in Test
> Cooling by Free Air Convection
Constant Voltage
MODELS
35W
SPECIFICATIONS
12~35W IP30 Rated LED Power Supplies
FEATURES
Constant Current
Constant Current
MODELS
Constant Voltage
MODELS
EFF.
MODELS
Model
Output
TOL.
RIPPLE
EFF.
Model
Output
TOL.
RIPPLE
Model
Output
TOL.
RIPPLE
EFF.
Model
Output
TOL.
RIPPLE
EFF.
LSU25-C350
350mA (42~70V)
±5%
300mAp-p
83%
LSU25-V5
5V (0~3.5A)
±5%
120mVp-p 75%
LSU35-C350
350mA (60~100V)
±5%
350mAp-p
87%
LSU35-V5
5V (0~5A)
±5%
120mVp-p
75%
LSU25-C500
500mA (30~50V)
±5%
300mAp-p
85%
LSU25-V12
12V (0~2.1A)
±5%
150mVp-p 82%
LSU35-C500
500mA (42~70V)
±5%
350mAp-p
86%
LSU35-V12
12V (0~3A)
±5%
150mVp-p
82%
LSU25-C700
700mA (22~36V)
±5%
300mAp-p
86%
LSU25-V15
15V (0~1.68A)
±5%
120mVp-p 78%
LSU35-C700
700mA (30~50V)
±5%
350mAp-p
86%
LSU35-V15
15V (0~1.68A)
±5%
150mVp-p
78%
LSU25-C1050
1050mA (15~24V)
±5%
300mAp-p
86%
LSU25-V24
24V (0~1.05A)
±5%
150mVp-p 84%
LSU35-C1050
1050mA (20~33V)
±5%
350mAp-p
85%
LSU35-V24
24V (0~1.5A)
±5%
180mVp-p
84%
LSU25-V36
36V (0~0.7A)
±5%
150mVp-p 86%
LSU35-V36
36V (0~1A)
±5%
180mVp-p
86%
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC/120-370VDC, 47~63Hz
INPUT CURRENT (Typ.)
0.8A/115VAC, 0.4A/230VAC(full load)
INRUSH CURRENT (Typ.)
COLD START, 45A/230VAC
LINE REGULATION
±1%
LOAD REGULATION
±3%
SETUP, RISE TIME (Typ.)
VOLTAGE RANGE, FREQUENCY
90-264VAC/120-370VDC, 47~63Hz
INPUT CURRENT (Typ.)
0.75A/115VAC, 0.5A/230VAC(full load)
INRUSH CURRENT (Typ.)
COLD START, 45A/230VAC
LINE REGULATION
±1%
LOAD REGULATION
±3%
1500ms, 30ms/230VAC at full load
SETUP, RISE TIME (Typ.)
1500ms, 40ms/230VAC at full load
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
TEMPERATURE COEFFICIENT
±0.2%/°C (0-50°C)
TEMPERATURE COEFFICIENT
±0.2%/°C (0-50°C)
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. MIL-HDBK-217F (25°C)
MTBF
400K hours min. MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=115VAC/230VAC
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=115VAC/230VAC
MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
3
Dimensions in mm
Dimensions in mm
Weight: 150g
Weight: 150g
3
15.3
84
150±10
18 AWG
DC
OUT
RED
BLACK
84
7.3
AC
IN
18 AWG
3
AC
IN
3
84
18 AWG
30
30
84
18 AWG
BLUE
BROWN
15,3
150±10
15,3
18 AWG
RED
BLACK
57
7.3
150±10
BLUE
BROWN
150±10
18 AWG
DC
OUT
7,3
57
7,3
34
LS SERIES
CHARACTERISTICS
15.3
LS SERIES
LS SERIES
25W
18 AWG
18 AWG
35
LC SERIES
20~40W IP67 Rated LED
Power Supplies
MODEL NUMBER STRUCTURE
LC
U
20 - C
350
D
Dimming Option
Blank = Without dimming
D = With 0~10V dimming
P = With PWM dimming
Output Parameter
CC type: Output Current(mA)
CV type: Output Voltage(Vdc) * Not yet available in this series
Output Type
C = Constant current type
V = Constant voltage type * Not yet available in this series
Maximum Output Power (W)
Input Voltage Range
U = Universal(90~305VAC)
Series Name
FEATURES
5 Year Warranty
Constant Current Output
Active Power Factor Correction
Universal AC Input Range: 90~305VAC
Short Circuit, Over Voltage, Over Load, Over Temperature Protections
Designed to Worldwide Safety Standards for Lighting
APPLICATIONS
Outdoor Lighting
String Lights
Wall Wash Lights
Spot Lighting
High/Low Bay Lighting
Optional Dimming (0~10V, PWM)
Certified to UL, CE
SERIES OVERVIEW
SERIES
VIN
OUTPUT (CC)
CASE
LC_20-C
90~305VAC
350, 450, 700, 1050mA
113 x 41.5 x 30 mm
LC_30-C
90~305VAC
350, 450, 700, 1050mA
113 x 41.5 x 30 mm
LC_40-C
90~305VAC
350, 450, 700, 1050, 1280,
1400, 1660mA
95 x 70 x 32 mm
Safety Standards: UL8750, EN61347-1, EN61347-2-13
EMC Standards: EN55015, FCC Part15 Class B, EN61000-3-2,
EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
36
SAFETY APPROVAL
37
LC SERIES
LC SERIES
20/30W
SPECIFICATIONS
20~40W IP67 Rated LED Power Supplies
FEATURES
FEATURES
> 5 Year Warranty
> Universal AC Input Range: 90-305VAC
> High PF up to 0.99
> Short Circuit and Over Voltage Protections
> Cooling by Free Air Convection
> Optional Dimming (0~10V, PWM)
> 5 Year Warranty
> Universal AC Input Range: 90-305VAC
> High PF up to 0.99
> Short Circuit and Over Voltage Protections
> Cooling by Free Air Convection
> Optional Dimming (0~10V, PWM)
Constant Current
MODELS
MODELS
Model ①
Output
TOL.
VNO-LOAD
EFF.
Model ①
Output
TOL.
VNO-LOAD
EFF.
Model ①
Output
TOL.
VNO-LOAD
EFF.
Model ①
Output
TOL.
VNO-LOAD
EFF.
LCU20-C350
350mA (34~57V)
±5%
63V
88%
LCU30-C350
350mA (52~86V)
±5%
95V
88%
LCU40-C350
350mA (69~114V)
±5%
123V
91%
LCU40-C1280
1280mA (19~31V)
±5%
34V
88%
LCU20-C450
450mA (27~45V)
±5%
50V
87%
LCU30-C450
450mA (40~67V)
±5%
74V
87%
LCU40-C450
450mA (53~89V)
±5%
98V
91%
LCU40-C1400
1400mA (17~29V)
±5%
32V
88%
LCU20-C700
700mA (18~29V)
±5%
32V
86%
LCU30-C700
700mA (26~43V)
±5%
48V
86%
LCU40-C700
700mA (34~57V)
±5%
63V
90%
LCU40-C1660
1660mA (14~24V)
±5%
27V
87%
LCU20-C1050
1050mA (12~19V)
±5%
21V
85%
LCU30-C1050
1050mA (17~29V)
±5%
32V
84%
LCU40-C1050
1050mA (23~38V)
±5%
42V
89%
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
20W: 0.98/110VAC, 0.95/220VAC; 30W: 0.99/110VAC, 0.95/220VAC(70%~100% load)
INPUT CURRENT (Typ.)
0.33A/110VAC, 0.16A/220VAC (full load)
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.43A/110VAC, 0.21A/220VAC (full load)
COLD START, 24A/230VAC (full load)
INRUSH CURRENT (Typ.)
COLD START, 35A/230VAC (full load)
LINE REGULATION
5%
LINE REGULATION
1%
LOAD REGULATION
5%
LOAD REGULATION
3%
SETUP, RISE TIME
≤2S/230VAC (cold start, power on)
SETUP, RISE TIME
≤2S/230VAC (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL1310 Class2, UL1012 UL935 CAN/CSA-22.2 No.0, CSA-C22.2 No.107.1,
CSA-C22.2 No.250.0, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL1310 Class2, UL1012 UL935 CAN/CSA-22.2 No.0, CSA-C22.2 No.107.1,
CSA-C22.2 No.250.0, EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF, LIFE TIME
450K hours min. MIL-HDBK-217F (25°C), 80K hours min. MIL-HDBK-217F (25°C)
INPUT
OUTPUT
① Add suffix for dimming option, "D" (0~10V), "P" (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
PROTECTION
ENVIRONMENT
SAFETY
LC SERIES
LC SERIES
SPECIFICATIONS
Constant Current
(30W)
CHARACTERISTICS
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF, LIFE TIME
450K hours min. MIL-HDBK-217F (25°C), 80K hours min. MIL-HDBK-217F (25°C)
① Add suffix for dimming option, "D" (0~10V), "P" (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
MECHANICAL SPECIFICATION
38
40W
20~40W IP67 Rated LED Power Supplies
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 220g
Weight: 330g
39
LE SERIES
20~100W IP67 Rated LED
Power Supplies
MODEL NUMBER STRUCTURE
LE
U
20 - C
350
Output Parameter
CC type: Output Current(mA)
CV type: Output Voltage(Vdc)
Output Type
C = Constant current type
V = Constant voltage type
Maximum Output Power (W)
Input Voltage Range
U = Universal (90~264VAC)
Series Name
FEATURES
3 Year Warranty
IP67 Rated for Outdoor Lighting
Operating Temperature Range: -25°C ~ +70°C
Universal Input Range: 90~264VAC
High Efficiency up to 87%
Short Circuit and Over Voltage Protections
APPLICATIONS
Outdoor Lighting
String Lights
Wall Wash Lights
Spot Lighting
SERIES
VIN
OUTPUT (CC or CV)
CASE
High/Low Bay Lighting
LEU20-C/V
90~264VAC
350, 700mA
5, 12, 15, 24, 36Vdc
140 x 30 x 22 mm
LEU35-C/V
90~264VAC
700, 1050, 1400mA
5, 12, 15, 24, 36, 48Vdc
148 x 40 x 30 mm
LEU60-C/V
90~264VAC
1050, 1400, 1750mA
5, 12, 15, 24, 36, 48Vdc
162.5 x 42.5 x 32 mm
LEU100-V
90~264VAC
5, 12, 15, 24, 36, 48Vdc
190 x 52 x 37 mm
Safety Standards: Design refer to UL879, UL1310, EN60950-1
EMC Standards: EN55022 Class B, EN61000-3-2 Class A,
EN61000-3-3
40
SERIES OVERVIEW
SAFETY APPROVAL
41
LE SERIES
LE SERIES
20W
SPECIFICATIONS
20~100W IP67 Rated LED Power Supplies
FEATURES
> 3 Year Warranty
> Application for LED Lighting
and Electronic Screen
Constant Current
> Universal AC Input Range
> Short Circuit and Over Voltage
Protections
> Cooling by Free Air Convection
> Class II, No FG
Constant Voltage
MODELS
Model
Output
TOL.
RIPPLE
350mA (29-48V)
±5%
200mVp-p 83%
EFF.
LEU20-C700
700mA (18-30V)
±5%
200mVp-p 83%
SAFETY
42
MODELS
Model
Output
TOL.
RIPPLE
EFF.
Model
Output
TOL.
RIPPLE
EFF(typ.)
Model
Output
TOL.
RIPPLE
EFF.
LEU20-V5
5V (3A Max.)
±5%
80mVp-p
77%
LEU35-C700
700mA (29-48V)
±5%
200mVp-p
85%
LEU35-V5
5V (6A Max.)
±6%
80mVp-p
78%
LEU20-V12
12V (1.67A Max.)
±5%
120mVp-p 81%
LEU35-C1050
1050mA (18-30V)
±5%
200mVp-p
85%
LEU35-V12
12V (3A Max.)
±5%
120mVp-p 84%
LEU20-V15
15V (1.33A Max.)
±5%
120mVp-p 83%
LEU35-C1400
1400mA (15-24V)
±5%
200mVp-p
85%
LEU35-V15
15V (2.4A Max.)
±5%
150mVp-p 84%
LEU20-V24
24V (0.84A Max.)
±5%
120mVp-p 83%
LEU35-V24
24V (1.5A Max.)
±5%
150mVp-p 85%
LEU35-V36
36V (1A Max.)
±5%
150mVp-p 85%
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
INPUT CURRENT
0.55A MAX./115VAC, 0.35A MAX./230VAC (full load)
INRUSH CURRENT (Typ.)
COLD START, 70A/230VAC
LINE REGULATION
±1%
LOAD REGULATION
±2%
SETUP, RISE TIME
≤500ms, 250ms (CC); 500ms, 25ms/230vac (CV) (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150%; Shut off output voltage, Diode clamp type
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
TEMPERATURE COEFFICIENT
INPUT
OUTPUT
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
INPUT CURRENT
1.1A MAX./115VAC, 0.7A MAX./230VAC (full load)
INRUSH CURRENT (Typ.)
COLD START, 55A/230VAC
LINE REGULATION
±1%
LOAD REGULATION
±2% (±5%/5V)
SETUP, RISE TIME
≤500ms, 120ms/230VAC (CC); 500ms, 20ms (CV), (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150%; Shut off output voltage, Diode clamp type
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
±0.03%/°C (0-50°C)
TEMPERATURE COEFFICIENT
±0.03%/°C (0-50°C)
SAFETY STANDARDS
Design refer to UL879, UL1310, EN60950-1
SAFETY STANDARDS
Design refer to UL1301, EN60950-1
EMC
Compliance to EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3
EMC
Compliance to EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3
MTBF
500K hours min. MIL-HDBK-217F (25°C)
MTBF
700K hours min. MIL-HDBK-217F (25°C)
PROTECTION
ENVIRONMENT
SAFETY
1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes
1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes
MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 220g
Weight: 340g
LE SERIES
LE SERIES
ENVIRONMENT
Constant Voltage
MODELS
CHARACTERISTICS
PROTECTION
> 3 Year Warranty
> Application for LED Lighting
and Electronic Screen
Constant Current
MODELS
LEU20-C350
OUTPUT
SPECIFICATIONS
FEATURES
> Universal AC Input Range
> Short Circuit and Over Voltage
Protections
> Cooling by Free Air Convection
> Class II, No FG
INPUT
35W
20~100W IP67 Rated LED Power Supplies
43
LE SERIES
LE SERIES
60W
SPECIFICATIONS
20~100W IP67 Rated LED Power Supplies
FEATURES
> 3 Year Warranty
> Application for LED Lighting
and Electronic Screen
> Universal AC Input Range
> Short Circuit and Over Voltage
Protections
> Cooling by Free Air Convection
> Class II, No FG
> 3 Year Warranty
> Application for LED Lighting
and Electronic Screen
Constant Voltage
MODELS
Constant Current
MODELS
Model
EFF.
Constant Voltage
Output
TOL.
RIPPLE
EFF.
76%
Constant Voltage
MODELS
MODELS
Model
Output
TOL.
RIPPLE
LEU60-V5
5V (8A Max.)
±8%
80mVp-p
Model
Output
TOL.
RIPPLE
EFF.
Model
Output
TOL.
RIPPLE
LEU60-C1050
1050mA (29-48V)
±5%
200mVp-p 86%
LEU60-V12
12V (5A Max.)
±5%
120mVp-p 83%
LEU100-V5
5V (12A Max.)
±5%
80mVp-p
80%
LEU100-V24
24V (4.2A Max.)
±5%
150mVp-p 87%
EFF.
LEU60-C1400
1400mA (26-42V)
±5%
200mVp-p 85%
LEU60-V15
15V (4A Max.)
±5%
120mVp-p 83%
LEU100-V12
12V (8.5A Max.)
±5%
120mVp-p 85%
LEU100-V36
36V (2.8A Max.)
±5%
150mVp-p 87%
LEU60-C1750
1750mA (21-34V)
±5%
200mVp-p 86%
LEU60-V24
24V (2.5A Max.)
±5%
150mVp-p 85%
LEU100-V15
15V (6.7A Max.)
±5%
120mVp-p 87%
LEU100-V48
48V (2.1A Max.)
±5%
150mVp-p 88%
LEU60-V36
36V (1.67A Max.)
±5%
150mVp-p 85%
LEU60-V48
48V (1.25A Max.)
±5%
150mVp-p 85%
CHARACTERISTICS
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
INPUT CURRENT
1.2A MAX./115VAC, 1A MAX./230VAC (full load)
INRUSH CURRENT (Typ.)
COLD START, 60A/230VAC
LINE REGULATION
±1%
LOAD REGULATION
±2% (±6%/5V)
SETUP, RISE TIME
≤500ms, 120ms/230VAC (CC); 500ms, 200ms (CV) (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150%; Shut off output voltage, Diode clamp type
OPERATING
INPUT
OUTPUT
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
INPUT CURRENT
2.2A MAX./115VAC, 1.2A MAX./230VAC (full load)
INRUSH CURRENT (Typ.)
COLD START, 75A/230VAC
LINE REGULATION
±1%
LOAD REGULATION
±2%
SETUP, RISE TIME
2000ms, 25ms/115VAC at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER CURRENT
110-150%; Hiccup mode, recovers automatically after fault condition is removed
Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing
OVER VOLTAGE
110-150%; recovers automatically after fault condition is removed
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing
TEMPERATURE COEFFICIENT
±0.03%/°C (0-50°C)
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH
SAFETY STANDARDS
Design refer to UL879, UL1310, EN60950-1
TEMPERATURE COEFFICIENT
±0.03%/°C (0-45°C)
EMC
Compliance to EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3
SAFETY STANDARDS
Design refer to UL879, UL1310, EN60950-1
MTBF
700K hours min. MIL-HDBK-217F (25°C)
EMC
Compliance to EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3
MTBF
600K hours min. MIL-HDBK-217F (25°C)
PROTECTION
ENVIRONMENT
SAFETY
1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes
MECHANICAL SPECIFICATION
Dimensions in mm
Weight: 400g
LE SERIES
INPUT
LE SERIES
SPECIFICATIONS
FEATURES
> Universal AC Input Range
> Short Circuit and Over Voltage
Protections
> Cooling by Free Air Convection
> Class II, No FG
44
100W
20~100W IP67 Rated LED Power Supplies
1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes
MECHANICAL SPECIFICATION
Dimensions in mm
Weight: 630g
45
LF SERIES
35~150W IP67 Rated Power Supplies
with PFC
MODEL NUMBER STRUCTURE
LF
U
20 - C
350
R
L
Warranty Year
Blank: 3 Year Warranty
L: 5 Year Warranty
Ripple * Not available for 100W/150W models
Blank: High Ripple
R: Low Ripple * Not available for LFB models
Output Parameter
CC type: Output Current(mA)
CV type: Output Voltage(Vdc)
Output Type
C = Constant current type
V = Constant voltage type
Maximum Output Power (W)
Input Voltage Range
U = Universal (90~264VAC)
B = 230VAC(180~264VAC) * Only available for 35W/60W CV models
FEATURES
3 or 5 Year Warranty Selectable
Active Power Factor Correction
IP67 Rated for Outdoor Lighting
Operating Temperature Range: -25°C ~ +70°C
Universal Input Range: 90~264VAC
High Efficiency
APPLICATIONS
Outdoor Lighting
String Lights
Wall Wash Lights
Spot Lighting
High/Low Bay Lighting
Short Circuit and Over Voltage Protections
Safety Standards: Design refer to UL879, UL1310, TUV EN60950-1
EMC Standards: EN55022 Class B, EN61000-3-2 Class A,
EN61000-3-3
46
Series Name
SAFETY APPROVAL
SERIES OVERVIEW
SERIES
VIN
OUTPUT (CC or CV)
CASE
90~264VAC
350, 500, 700, 1050mA
5, 12, 15, 24, 36Vdc
148 x 40 x 30 mm
90~264VAC
350, 700, 1050, 1400, 2100, 2800mA
5, 12, 15, 24, 36, 48Vdc
162.5 x 42.5 x 32 mm
LFU100-C/V
90~264VAC
700, 1050, 1400, 1750, 2100mA
12, 15, 24, 36, 48Vdc
190 x 52 x 37 mm
LFU150-C/V
90~264VAC
700, 1050, 1400, 1750, 2100, 2800, 3150mA
12, 15, 24, 36, 48Vdc
190 x 52 x 37 mm
LFU35-C
LF[ ]35-V
LFU60-C
LF[ ]60-V
47
LF SERIES
LF SERIES
35W
SPECIFICATIONS
35~150W IP67 Rated Power Supplies with PFC
FEATURES
> 3/5 Year Warranty
> Application for LED Lighting
and Electronic Screen
> Active Power Factor Correction
> Universal AC Input Range
> Cooling by Free Air Convection
> Active Power Factor Correction
> Class II, No FG
Constant Voltage
MODELS
Model ①
Output
TOL.
RIPPLE② EFF(typ.)
Output
TOL.
VNO-LOAD
EFF(typ.)
LFU35-V5
5V (6A Max.)
±5%
5%/50%
85%
LFU35-C350
350mA (70-100V)
±5%
128V
85%
LFU35-V12
12V (3A Max.)
±5%
5%/50%
85%
LFU35-C500
500mA (49-70V)
±5%
80V
85%
LFU35-V15
15V (2.4A Max.)
±5%
5%/50%
85%
LFU35-C700
700mA (35-50V)
±5%
60V
85%
LFU35-V24
24V (1.5A Max.)
±5%
5%/50%
85%
LFU35-C1050
1050mA (23-33V)
±5%
40V
85%
LFU35-V36
36V (1A Max.)
±5%
5%/50%
85%
*[ ] = U or B, U (90~264VAC), B (180~264VAC)
LF SERIES
SAFETY
MODELS
Model ①
Output
TOL.
RIPPLE ② EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
LFU60-V5
5V (8A Max.)
±5%
5%/50%
85%
LFU60-C350
350mA (120-171V)
±5%
205V
85%
LFU60-V12
12V (5A Max.)
±5%
5%/50%
85%
LFU60-C700
700mA (60-86V)
±5%
103V
85%
LFU60-V15
15V (4A Max.)
±5%
5%/50%
85%
LFU60-C1050
1050mA (40-57V)
±5%
68V
85%
LFU60-V24
24V (2.5A Max.)
±5%
5%/50%
85%
LFU60-C1400
1400mA (30-43V)
±5%
51V
85%
LFU60-V36
36V (1.67A Max.)
±5%
5%/50%
85%
LFU60-C2100
2100mA (20-29V)
±5%
35V
85%
LFU60-V48
48V (1.25A Max.)
±5%
5%/50%
85%
LFU60-C2800
2800mA (14-21V)
±5%
25V
85%
*[ ] = U or B, U (90~264VAC), B (180~264VAC)
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
POWER FACTOR (Typ.)
0.9/230VAC (70%~100% load)
INPUT CURRENT (Typ.)
0.2A/230VAC (full load)
POWER FACTOR (Typ.)
0.9/230VAC (70%~100% load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.36A/230VAC(full load)
COLD START, 35A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 35A/230VAC
LINE REGULATION (Typ.)
±3%
LINE REGULATION
±3%
LOAD REGULATION (Typ.)
±3%
LOAD REGULATION
±3%
SETUP, RISE TIME (Typ.)
2S (CC); 1S (CV) (cold start, power on)
SETUP, RISE TIME
2S (CC); 1S (CV) (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150%; Shut off output voltage, return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150%; Shut off output voltage, return to normal operation after the power is turn-on again
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
TEMPERATURE COEFFICIENT
±0.03%/°C (0-50°C)
TEMPERATURE COEFFICIENT
±0.03%/°C (0-50°C)
SAFETY STANDARDS
Design refer to UL8750, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547
MTBF
400K hours min. MIL-HDBK-217F (25°C)
MTBF
400K hours min. MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
① Above items are default to 3 year warranty, add suffix "L" for 5 year warranty
② Above items are default to high ripple, add suffix "R" for low ripple(except LFB35-V models)
1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes
① Above items are default to 3 year warranty, add suffix "L" for 5 year warranty
② Above items are default to high ripple , add suffix "R" for low ripple(except LFB60-V models)
1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes
MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
AC(N) BLUE
AC(L) BROWEN
Dimensions in mm
Dimensions in mm
Weight: 340g
Weight: 400g
LF SERIES
CHARACTERISTICS
ENVIRONMENT
Constant Voltage
MODELS
Model ①
PROTECTION
> 3/5 Year Warranty
> Short Circuit and Over Voltage
Protections
Constant Current
MODELS
Constant Current
OUTPUT
SPECIFICATIONS
FEATURES
> Universal AC Input Range
> Short Circuit and Over Voltage
Protections
> Cooling by Free Air Convection
> Class II, No FG
INPUT
60W
35~100W IP67 Rated Power Supplies with PFC
UL1015 18AWG
T case
UL1015 18AWG
+V(RED)
-V(BLACK)
48
49
LF SERIES
LF SERIES
100W
SPECIFICATIONS
35~150W IP67 Rated Power Supplies with PFC
FEATURES
150W
SPECIFICATIONS
35~150W IP67 Rated Power Supplies with PFC
FEATURES
> Universal AC Input Range
> Short Circuit and Over Voltage
Protections
> Cooling by Free Air Convection
> Active Power Factor Correction
> 3/5 Year Warranty
> Class II, No FG
> 100% Burn-in Test
> Universal AC Input Range
> Cooling by Free Air Convection
> Active Power Factor Correction
> 100% Burn-in Test
> 3/5 Year Warranty
> Class II, No FG
> Short Circuit and Over Voltage
Protections
Constant Current
MODELS
Constant Current
Constant Voltage
MODELS
MODELS
TOL.
VNO-LOAD
EFF(typ.)
LFU150-C700
700mA (171-214)
±5%
256V
92%
Model ①
Output
TOL.
RIPPLE
EFF(typ.)
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
RIPPLE
EFF(typ.)
LFU150-C1050
1050mA (114-142)
±5%
170V
92%
LFU150-V12
12V(8A Max.)
±5%
5%
93%
LFU100-C700
700mA (114-142)
±5%
170V
90%
LFU100-V12
12V (7A Max.)
±5%
5%
87%
LFU150-C1400
1400mA (86-107)
±5%
128V
92%
LFU150-V15
15V(8A Max.)
±5%
5%
93%
LFU100-C1050
1050mA (76-95)
±5%
114V
90%
LFU100-V15
15V (6.7A Max.)
±5%
5%
87%
LFU150-C1750
1750mA (68-86)
±5%
103V
92%
LFU150-V24
24V(5A Max.)
±5%
5%
93%
LFU100-C1400
1400mA (57-71)
±5%
85V
90%
LFU100-V24
24V (4.2A Max.)
±5%
5%
87%
LFU150-C2100
2100mA (57-71)
±5%
85V
92%
LFU150-V36
36V(3.33A Max.)
±5%
5%
93%
LFU100-C1750
1750mA (46-57)
±5%
68V
90%
LFU100-V36
36V (2.8A Max.)
±5%
5%
87%
LFU150-C2800
2800mA (43-54)
±5%
65V
92%
LFU150-V48
48V(3.15A Max.)
±5%
5%
93%
LFU100-C2100
2100mA (39-48)
±5%
58V
90%
LFU100-V48
48V (2.1A Max.)
±5%
5%
87%
LFU150-C3150
3150mA (39-48)
±5%
58V
92%
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-264VAC, 47~63Hz
POWER FACTOR (Typ.)
0.9/230VAC (70%~100% load)
INPUT CURRENT (Typ.)
0.6A/230VAC (full load)
POWER FACTOR (Typ.)
0.94/230VAC (70%~100% load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.8A/230VAC (full load)
COLD START, 35A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 50A/230VAC
LINE REGULATION
±1%
LINE REGULATION
±1%
LOAD REGULATION
±2%
LOAD REGULATION
±2%
SETUP, RISE TIME
1S (cold start, power on)
SETUP, RISE TIME
2S (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150%; Shut off output voltage, return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150%; Shut off output voltage, return to normal operation after the power is turn-on again
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -25°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
TEMPERATURE COEFFICIENT
±0.03%/°C (0-50°C)
TEMPERATURE COEFFICIENT
±0.03%/°C (0-50°C)
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547
MTBF
200K hours min. MIL-HDBK-217F (25°C)
MTBF
200K hours min. MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
① Above items are default to 3 year warranty, add suffix "L" for 5 year warranty
1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes
① Above items are default to 3 year warranty, add suffix "L" for 5 year warranty
1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC
2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor
3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes
MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 630g
Weight: 630g
LF SERIES
①
CHARACTERISTICS
LF SERIES
MODELS
Output
Output
Model
50
Constant Voltage
Model ①
51
LG SERIES
30~85W LED Power Supplies for
Outdoor Lighting
MODEL NUMBER STRUCTURE
LG
U
75 - C
350
D
Dimming Option
Blank=Without dimming
D = With 0~10V dimming
P = With PWM dimming
Output Parameter
CC type: Output Current (mA)
Output Type
C = Constant current type
Maximum Output Power (W)
Input Voltage Range
U = Universal (90~305VAC)
FEATURES
APPLICATIONS
IP67 Rated for Outdoor Lighting
Outdoor Lighting
Universal Input Range: 90~305VAC
Street Lighting
High Efficiency up to 93%
Active Power Factor Correction, 2 Level
Operating Temperature Range: -35°C ~ +70°C
Optional Dimming (0~10V, PWM)
Spot Lighting
Flood Lighting
High/Low Bay Lights
SERIES OVERVIEW
SERIES
VIN
OUTPUT (CC)
CASE
LGU30-C
90~305VAC
350, 450, 700, 1050mA
193 x 43.5 x 34.5 mm
5 Year Warranty
LGU40-C
90~305VAC
350, 450, 700, 1050, 1280, 1400, 1660mA
193 x 43.5 x 34.5 mm
Safety Standards: Design refer to UL8750, UL935, UL1012,
UL1310 CLASS 2, EN61347-1 , EN61347-2-13
LGU50-C
90~305VAC
350, 450, 700, 1050, 1400mA
193 x 43.5 x 34.5 mm
LGU60-C
90~305VAC
350, 450, 700, 1050, 1400, 1750, 2100mA
177 x 65.5 x 39.5 mm
LGU75-C
90~305VAC
350, 450, 700, 1050, 1400, 1750, 2100mA
177 x 65.5 x 39.5 mm
LGU85-C
90~305VAC
350, 700, 1050, 1400, 1750, 2100, 2800mA
177 x 65.5 x 39.5 mm
All-Round Protections: Short Circuit, Over Voltage, Over Temperature
Landscape Lighting
Certified to UL and CE
EMC Standards: EN55015, FCC Part 15 Class B, EN61000-3-2,
EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547
52
Series Name
SAFETY APPROVAL
53
LG SERIES
30~85W LED Power Supplies for Outdoor Lighting
LG SERIES
30W
SPECIFICATIONS
FEATURES
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
> Universal Input: 90~305VAC
> High Efficiency up to 88%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
Constant Current
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
Constant Current
MODELS
MODELS
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
LGU30-C350
350mA (60~86V)
±5%
111V
88%
LGU40-C350
350mA (80~114V)
±5%
148V
88%
LGU40-C1280
1280mA (22~31V)
±5%
40V
88%
LGU30-C450
450mA (47~67V)
±5%
87V
88%
LGU40-C450
450mA (63~89V)
±5%
115V
88%
LGU40-C1400
1400mA (21~29V)
±5%
37V
88%
LGU30-C700
700mA (30~43V)
±5%
55V
88%
LGU40-C700
700mA (40~57V)
±5%
74V
88%
LGU40-C1660
1660mA (17~24V)
±5%
31V
88%
LGU30-C1050
1050mA (20~29V)
±5%
37V
88%
LGU40-C1050
1050mA (27~38V)
±5%
49V
88%
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.95/220VAC(70%~100% full load)
INPUT CURRENT
0.33A/110VAC, 0.16A/220VAC (full load)
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/230VAC (70%~100% full load)
INPUT CURRENT
INRUSH CURRENT
0.21A/220VAC (full load)
COLD START, 24A/230VAC
INRUSH CURRENT
COLD START, 35A/230VAC
LINE REGULATION
1%
LINE REGULATION
1%
LOAD REGULATION
3%
LOAD REGULATION
3%
SETUP, RISE TIME
2S at full load (cold start, power on)
SETUP, RISE TIME
2S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000,
EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000,
EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
PROTECTION
ENVIRONMENT
SAFETY
LG SERIES
CHARACTERISTICS
LG SERIES
SPECIFICATIONS
FEATURES
> Universal Input: 90~305VAC
> High Efficiency up to 88%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
54
40W
30~85W LED Power Supplies for Outdoor Lighting
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 455g
Weight: 455g
55
LG SERIES
LG SERIES
50W
SPECIFICATIONS
30~85W LED Power Supplies for Outdoor Lighting
FEATURES
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
> Universal Input: 90~305VAC
> High Efficiency up to 88%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
Constant Current
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
Constant Current
MODELS
MODELS
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
LGU50-C350
350mA (100~143V)
±5%
185V
88%
LGU50-C1050
1050mA (34~48V)
±5%
62V
88%
LGU60-C350
350mA (120~171V)
±5%
222V
85%
LGU60-C1400
1400mA(31~43V)
±5%
55V
85%
LGU50-C450
450mA (78~111V)
±5%
144V
88%
LGU50-C1400
1400mA (26~36V)
±5%
46V
88%
LGU60-C450
450mA (93~133V)
±5%
172V
85%
LGU60-C1750
1750mA(24~34V)
±5%
44V
85%
LGU50-C700
700mA (50~71V)
±5%
92V
88%
LGU50-C2100
2100mA (17~24V)
±5%
31V
88%
LGU60-C700
700mA (60~85V)
±5%
110V
85%
LGU60-C2100
2100mA(20~28V)
±5%
36V
85%
LGU60-C1050
1050mA (40~57V)
±5%
74V
85%
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/230VAC (70%~100% full load)
INPUT CURRENT
0.26A/230VAC (full load)
POWER FACTOR (Typ.)
0.99/110VAC, 0.95/230VAC (70%~100% full load)
INPUT CURRENT
INRUSH CURRENT
0.32A/230VAC (full load)
COLD START, 35A/230VAC
INRUSH CURRENT
COLD START, 65A/230VAC
LINE REGULATION
1%
LINE REGULATION
1%
LOAD REGULATION
3%
LOAD REGULATION
3%
SETUP, RISE TIME
2S at full load (cold start, power on)
SETUP, RISE TIME
2S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000,
EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000,
EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF, LIFE TIME
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
SAFETY
LG SERIES
CHARACTERISTICS
LG SERIES
SPECIFICATIONS
FEATURES
> Universal Input: 90~305VAC
> High Efficiency up to 88%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
56
60W
30~85W LED Power Supplies for Outdoor Lighting
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 455g
Weight: 745g
57
LG SERIES
LG SERIES
75W
SPECIFICATIONS
30~85W LED Power Supplies for Outdoor Lighting
FEATURES
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
> Universal Input: 90~305VAC
> High Efficiency up to 88%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
Constant Current
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
Constant Current
MODELS
MODELS
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL. VNO-LOAD EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model
Output
TOL. VNO-LOAD EFF(typ.)
LGU75-C350
350mA (150~214V)
±5%
278V
88%
LGU75-C1400
1400mA (38~54V)
±5%
70V
88%
LGU85-C350
350mA (170-243V)
±5%
315V
88%
LGU85-C1750
1750mA (35-49V)
±5%
63V
88%
LGU75-C450
450mA (117~167V)
±5%
217V
88%
LGU75-C1750
1750mA (30~43V)
±5%
55V
88%
LGU85-C700
700mA (85-121V)
±5%
157V
88%
LGU85-C2100
2100mA (28-40V)
±5%
52V
88%
LGU75-C700
700mA (75~107V)
±5%
139V
88%
LGU75-C2100
2100mA (26~36V)
±5%
46V
88%
LGU85-C1050
1050mA (56-81V)
±5%
105V
88%
LGU85-C2800
2800mA (21-30V)
±5%
39V
88%
LGU75-C1050
1050mA (50~71V)
±5%
92V
88%
LGU85-C1400
1400mA (43-61V)
±5%
79V
88%
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/230VAC (70%~100% full load)
INPUT CURRENT
0.42A/230VAC (full load)
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
INRUSH CURRENT
0.9A/110VAC, 0.44A/220VAC (full load)
COLD START, 35A/230VAC
INRUSH CURRENT
COLD START, 50A/230VAC
LINE REGULATION
1%
LINE REGULATION
1%
LOAD REGULATION
3%
LOAD REGULATION
3%
SETUP, RISE TIME
2S at full load (cold start, power on)
SETUP, RISE TIME
1S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000,
EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000,
EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
SAFETY
LG SERIES
CHARACTERISTICS
LG SERIES
SPECIFICATIONS
FEATURES
> Universal Input: 90~305VAC
> High Efficiency up to 88%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
58
85W
30~85W LED Power Supplies for Outdoor Lighting
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 745g
Weight: 745g
59
LGS SERIES
100~250W LED Power Supplies for
Outdoor Lighting
MODEL NUMBER STRUCTURE
LGS
U 100 - C
350
D
Dimming Option
Blank=Without dimming
D = With 0~10V dimming
P = With PWM dimming
Output Parameter
CC type: Output Current (mA)
Output Type
C = Constant current type
Maximum Output Power (W)
Input Voltage Range
U = Universal (90~305VAC)
Series Name
FEATURES
APPLICATIONS
Constant Current Output
Outdoor Lighting
High Efficiency
Universal AC Input: 90-305VAC
Active Power Factor Correction
All-Round Protections: Short Circuit, Over Voltage, Over Temperature
IP67 Rated for Outdoor Lighting
Optional Dimming (0~10V, PWM)
Street Lighting
Spot Lighting
Flood Lighting
High/Low Bay Lights
Landscape Lighting
5 Year Warranty
Safety Standards: Design refer to UL8750, UL935, UL1012,
UL1310 CLASS 2, EN61347-1 , EN61347-2-13
EMC Standards: EN55015, FCC Part 15 Class B, EN61000-3-2,
EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
60
SAFETY APPROVAL
SERIES OVERVIEW
SERIES
VIN
OUTPUT (CC)
CASE
LGSU100-C
90~305VAC
350, 450, 700, 1050, 1400, 1750, 2100, 3150mA
228 x 65.5 x 39.5mm
LGSU120-C
90~305VAC
450, 700, 1050, 1400, 1750, 2100, 2800,
3150, 4200mA
228 x 65.5 x 39.5mm
LGSU150-C
90~305VAC
700, 1050, 1400, 1750, 2100, 2800,
3150, 4200mA
228 x 65.5 x 39.5mm
LGSU185-C
90~305VAC
700, 1050, 1400, 1750, 2100, 2450, 2800,
3150, 3500, 4200mA
226 x 67.5 x 39.7 mm
LGSU200-C
90~305VAC
700, 1050, 1400, 1750, 2100, 2450, 2800,
3150, 3500, 4200mA
226 x 67.5 x 39.7 mm
LGSU250-C
90~305VAC
1400, 1750, 2100, 2450, 2800, 3150, 3500,
4200, 4800mA
242 x 67.5 x 39.7mm
61
LGS SERIES
LGS SERIES
100W
SPECIFICATIONS
100~250W LED Power Supplies for Outdoor Lighting
FEATURES
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
> Universal Input: 90~305VAC
> High Efficiency up to 90%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
Constant Current
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
Constant Current
MODELS
MODELS
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
LGSU100-C350
350mA (214-286V)
±5%
371V
90%
LGSU100-C1400
1400mA (54-72V)
±5%
93V
90%
LGSU120-C450
450mA (200-267V)
±5%
347V
90%
LGSU120-C1750
1750mA (51-69V)
±5%
89V
90%
LGSU100-C450
450mA (166-222V)
±5%
288V
90%
LGSU100-C1750
1750mA (42-57V)
±5%
74V
90%
LGSU120-C700
700mA (128-171V)
±5%
222V
90%
LGSU120-C2100
2100mA (43-58V)
±5%
75V
90%
LGSU100-C700
700mA (107-143V)
±5%
185V
90%
LGSU100-C2100
2100mA (36-48V)
±5%
62V
90%
LGSU120-C1050
1050mA (85-114V)
±5%
148V
90%
LGSU120-C2800
2800mA (32-43V)
±5%
55V
90%
LGSU100-C1050
1050mA (71-95V)
±5%
123V
90%
LGSU100-C3150
3150mA (24-32V)
±5%
41V
90%
LGSU120-C1400
1400mA (64-86V)
±5%
111V
90%
LGSU120-C3150
3150mA (28-38V)
±5%
49V
90%
LGSU120-C4200
4200mA (21-29V)
±5%
37V
90%
CHARACTERISTICS
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
1A/110VAC, 0.5A/220VAC (full load)
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
INRUSH CURRENT
1.25A/110VAC, 0.6A/220VAC (full load)
COLD START, 65A/230VAC
INRUSH CURRENT
COLD START, 65A/230VAC
LINE REGULATION
1%
LINE REGULATION
1%
LOAD REGULATION
3%
LOAD REGULATION
3%
SETUP, RISE TIME
1S at full load (cold start, power on)
SETUP, RISE TIME
2S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
ENVIRONMENT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
PROTECTION
SAFETY
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
Dimensions in mm
Weight: 930g
MECHANICAL SPECIFICATION
Dimensions in mm
Weight: 930g
LGS SERIES
INPUT
LGS SERIES
SPECIFICATIONS
FEATURES
> Universal Input: 90~305VAC
> High Efficiency up to 90%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
62
120W
100~250W LED Power Supplies for Outdoor Lighting
63
LGS SERIES
LGS SERIES
150W
SPECIFICATIONS
100~250W LED Power Supplies for Outdoor Lighting
FEATURES
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
> Universal Input: 90~305VAC
> High Efficiency up to 92%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
Constant Current
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
Constant Current
MODELS
MODELS
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
LGSU150-C700
700mA (160-214V)
±5%
278V
90%
LGSU150-C2800
2800mA (40-54V)
±5%
70V
90%
LGSU185-C700
700mA (211-264V)
±5%
343V
92%
LGSU185-C2450
2450mA (60-76V)
±5%
98V
92%
LGSU150-C1050
1050mA (107-143V)
±5%
185V
90%
LGSU150-C3150
3150mA (36-48V)
±5%
62V
90%
LGSU185-C1050
1050mA (140-176V)
±5%
228V
92%
LGSU185-C2800
2800mA (52-66V)
±5%
85V
92%
LGSU150-C1400
1400mA (80-107V)
±5%
139V
90%
LGSU150-C3500
3500mA (32-43V)
±5%
55V
90%
LGSU185-C1400
1400mA (105-132V)
±5%
171V
92%
LGSU185-C3150
3150mA (47-59V)
±5%
76V
92%
LGSU150-C2100
2100mA (53-71V)
±5%
92V
90%
LGSU150-C4200
4200mA (27-36V)
±5%
46V
90%
LGSU185-C1750
1750mA (84-106V)
±5%
137V
92%
LGSU185-C3500
3500mA (42-53V)
±5%
68V
92%
LGSU185-C2100
2100mA (70-88V)
±5%
114V
92%
LGSU185-C4200
4200mA (35-44V)
±5%
57V
92%
CHARACTERISTICS
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
1.6A/110VAC, 0.75A/220VAC (full load)
POWER FACTOR (Typ.)
0.98/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
INRUSH CURRENT
1.86A/110VAC, 0.93A/220VAC (full load)
COLD START, 65A/230VAC
INRUSH CURRENT
COLD START, 65A/230VAC
LINE REGULATION
1%
LINE REGULATION
1%
LOAD REGULATION
3%
LOAD REGULATION
3%
SETUP, RISE TIME
1S at full load (cold start, power on)
SETUP, RISE TIME
1S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
ENVIRONMENT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM).
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
PROTECTION
SAFETY
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
Dimensions in mm
Weight: 930g
MECHANICAL SPECIFICATION
Dimensions in mm
Weight: 930g
LGS SERIES
INPUT
LGS SERIES
SPECIFICATIONS
FEATURES
> Universal Input: 90~305VAC
> High Efficiency up to 90%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
64
185W
100~250W LED Power Supplies for Outdoor Lighting
65
LGS SERIES
LGS SERIES
200W
SPECIFICATIONS
100~250W LED Power Supplies for Outdoor Lighting
FEATURES
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
> Universal Input: 90~305VAC
> High Efficiency up to 92%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
Constant Current
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
Constant Current
MODELS
MODELS
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
LGSU200-C700
700mA (228-286V)
±5%
371V
92%
LGSU200-C2450
2450mA (65-85V)
±5%
106V
92%
LGSU250-C1400
1400mA (143-179V)
±5%
232V
92%
LGSU250-C3150
3150mA (63-79V)
±5%
102V
92%
LGSU200-C1050
1050mA (152-190V)
±5%
247V
92%
LGSU200-C2800
2800mA (56-71V)
±5%
92V
92%
LGSU250-C1750
1750mA (114-143V)
±5%
185V
92%
LGSU250-C3500
3500mA (57-72V)
±5%
93V
92%
LGSU200-C1400
1400mA (114-143V)
±5%
185V
92%
LGSU200-C3150
3150mA (50-63V)
±5%
81V
92%
LGSU250-C2100
2100mA (95-119V)
±5%
154V
92%
LGSU250-C4200
4200mA (48-60V)
±5%
78V
92%
LGSU200-C1750
1750mA (91-114V)
±5%
148V
92%
LGSU200-C3500
3500mA (45-57V)
±5%
74V
92%
LGSU250-C2450
2450mA (81-102V)
±5%
132V
92%
LGSU250-C4800
4800mA (41-52V)
±5%
67V
92%
LGSU200-C2100
2100mA (76-95V)
±5%
123V
92%
LGSU200-C4200
4200mA (38-48V)
±5%
62V
92%
LGSU250-C2800
2800mA (71-79V)
±5%
115V
92%
CHARACTERISTICS
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
2.1A/110VAC, 1A/220VAC (full load)
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
INRUSH CURRENT
1.4A/230VAC (full load)
COLD START, 65A/230VAC
INRUSH CURRENT
COLD START, 65A/230VAC
LINE REGULATION
1%
LINE REGULATION
1%
LOAD REGULATION
3%
LOAD REGULATION
3%
SETUP, RISE TIME
1S at full load (cold start, power on)
SETUP, RISE TIME
1S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
ENVIRONMENT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
PROTECTION
SAFETY
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
Dimensions in mm
Weight: 930g
MECHANICAL SPECIFICATION
Dimensions in mm
Weight: 930g
LGS SERIES
INPUT
LGS SERIES
SPECIFICATIONS
FEATURES
> Universal Input: 90~305VAC
> High Efficiency up to 92%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
66
250W
100~250W LED Power Supplies for Outdoor Lighting
67
LGC SERIES
100~150W LED Power Supplies for
Outdoor Lighting
MODEL NUMBER STRUCTURE
LGC
U 100 - C
350
D
Dimming Option
Blank=Without dimming
D = With 0~10V dimming
P = With PWM dimming
Output Parameter
CC type: Output Current (mA)
Output Type
C = Constant current type
Maximum Output Power (W)
Input Voltage Range
U = Universal (90~305VAC)
Series Name
FEATURES
APPLICATIONS
Constant Current Output
Outdoor Lighting
High Efficiency
Universal AC Input: 90-305VAC
Active Power Factor Correction
All-Round Protections: Short Circuit, Over Voltage, Over Temperature
IP67 Rated for Outdoor Lighting
Optional Dimming (0~10V, PWM)
Street Lighting
Spot Lighting
Flood Lighting
High/Low Bay Lights
Landscape Lighting
5 Year Warranty
Safety Standards: Design refer to UL8750, UL935, UL1012,
UL1310 CLASS 2, EN61347-1 , EN61347-2-13
EMC Standards: EN55015, FCC Part 15 Class B, EN61000-3-2,
EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
68
SAFETY APPROVAL
SERIES OVERVIEW
SERIES
VIN
OUTPUT (CC)
CASE
LGCU100-C
90~305VAC
350, 450, 700, 1050, 1400, 1750, 2100, 3150mA
228 x 65.5 x 39.5mm
LGCU150-C
90~305VAC
700, 1050, 1400, 1750, 2100, 2800,
3150, 4200mA
228 x 65.5 x 39.5mm
69
LGC SERIES
LGS SERIES
100W
SPECIFICATIONS
100~150W LED Power Supplies for Outdoor Lighting
FEATURES
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
> Universal Input: 90~305VAC
> High Efficiency up to 89%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
Constant Current
> All-round Protection: SCP,
OVP, OTP
> Optional Dimming (0~10V,
PWM)
Constant Current
MODELS
MODELS
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
Model ①
Output
TOL.
VNO-LOAD
EFF(typ.)
LGCU100-C350
350mA (214-286V)
±5%
371V
89%
LGCU100-C1400
1400mA (54-72V)
±5%
93V
89%
LGCU150-C700
700mA (160-214V)
±5%
278V
89%
LGCU150-C2800
2800mA (40-54V)
±5%
70V
89%
LGCU100-C450
450mA (166-222V)
±5%
288V
89%
LGCU100-C1750
1750mA (42-57V)
±5%
74V
89%
LGCU150-C1050
1050mA (107-143V)
±5%
185V
89%
LGCU150-C3150
3150mA (36-48V)
±5%
62V
89%
LGCU100-C700
700mA (107-143V)
±5%
185V
89%
LGCU100-C2100
2100mA (36-48V)
±5%
62V
89%
LGCU150-C1400
1400mA (80-107V)
±5%
139V
89%
LGCU150-C3500
3500mA (32-43V)
±5%
55V
89%
LGCU100-C1050
1050mA (71-95V)
±5%
123V
89%
LGCU100-C3150
3150mA (24-32V)
±5%
41V
89%
LGCU150-C2100
2100mA (53-71V)
±5%
92V
89%
LGCU150-C4200
4200mA (27-36V)
±5%
46V
89%
CHARACTERISTICS
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
1A/110VAC, 0.5A/220VAC (full load)
INRUSH CURRENT
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (70%~100% full load)
INPUT CURRENT
1.6A/110VAC, 0.75A/220VAC (full load)
COLD START, 65A/230VAC
INRUSH CURRENT
COLD START, 65A/230VAC
LINE REGULATION
1%
LINE REGULATION
1%
LOAD REGULATION
3%
LOAD REGULATION
3%
SETUP, RISE TIME
1S at full load (cold start, power on)
SETUP, RISE TIME
1S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
200K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
ENVIRONMENT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
PROTECTION
SAFETY
① Add suffix for dimming option, “D” (0~10V), “P” (PWM).
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
Dimensions in mm
Weight: 930g
MECHANICAL SPECIFICATION
Dimensions in mm
Weight: 930g
LGC SERIES
INPUT
LGC SERIES
SPECIFICATIONS
FEATURES
> Universal Input: 90~305VAC
> High Efficiency up to 89%
> High PF up to 0.99
> 5 Year Warranty
> IP67 for Outdoor Lighting
70
150W
100~150W LED Power Supplies for Outdoor Lighting
71
LGE SERIES
80~250W LED Driver with Adjustable
Output Current
MODEL NUMBER STRUCTURE
LGE
U
80 - C
V
24
D
Dimming Option
Blank=Without dimming
D = With 0~10V dimming
P = With PWM dimming
Maximum Output Voltage
Constant Voltage Mode
Constant Current Mode
Maximum Output Power (W)
Input Voltage Range
U = Universal (90~305VAC)
FEATURES
APPLICATIONS
Constant Current and Constant Voltage Output
Outdoor Lighting
IP65 Rated for Outdoor Lighting
Street Lighting
Adjustable Output Current 60%~100%
Spot Lighting
Universal Input Range: 90~305VAC
Active Power Factor Correction
Operating Temperature Range: -35°C ~ +70°C
Optional Dimming (0~10V, PWM)
Flood Lighting
High/Low Bay Lights
Landscape Lighting
All-Round Protections: Short Circuit, Over Voltage, Over Temperature
5 Year Warranty
Safety Standards: Design refer to UL8750, UL935, UL1012,
UL1310 CLASS 2, EN61347-1 , EN61347-2-13
EMC Standards: Compliance to EN55015, FCC Part 15 Class B,
EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
72
SAFETY APPROVAL
Series Name
SERIES OVERVIEW
SERIES
VIN
OUTPUT (CC or CV)
CASE
LGEU80-C
90~305VAC
1500, 1700, 2200, 3400, 5000mA
177 x 68 x 38.8 mm
LGEU100-C
90~305VAC
700, 1050, 1400, 2100, 2800, 4200, 8300mA
215 x 68 x 38.8 mm
LGEU150-C
90~305VAC
700, 1050, 1400, 2100, 2800, 3150, 3500,
4200, 6250mA
215 x 68 x 38.8 mm
LGEU200-C
90~305VAC
1400, 1750, 2100, 2400, 2800, 3150, 3500,
4200, 5500, 8300mA
226 x 68 x 38.8 mm
LGEU250-C
90~305VAC
1400, 1750, 2100, 2450, 2800, 3150, 3500,
4200, 5000, 8300mA
244 x 68 x 38.8 mm
73
LGE SERIES
80~250W LED Driver with Adjustable Output Current
LGE SERIES
80W
SPECIFICATIONS
FEATURES
FEATURES
> Universal Input: 90~305Vac
> All-round Protection: SCP,
> Adjustable Output Current 60%~100% OVP, OTP
> High PF up to 0.99
> Optional Dimming (0~10V,
> 5 Year Warranty
PWM)
> IP65 for Outdoor Lighting
> Universal Input: 90~305Vac
> All-round Protection: SCP,
> Adjustable Output Current 60%~100% OVP, OTP
> High PF up to 0.99
> Optional Dimming (0~10V,
> 5 Year Warranty
PWM)
> IP65 for Outdoor Lighting
Constant Current / Constant Voltage
Constant Current / Constant Voltage
MODELS
Model ①
Output-C
Output-V
VNO-LOAD
EFF(typ.)
Model ①
Output-C
Output-V
VNO-LOAD EFF(typ.)
Model ①
Output-C
Output-V
VNO-LOAD EFF(typ.)
LGEU80-CV54
1500mA
38-54V
70V
90%
LGEU100-CV142
700mA
107-142V
184V
88%
LGEU100-CV24
4200mA
18-24V
31V
88%
LGEU80-CV48
1700mA
34-48V
62V
90%
LGEU100-CV95
1050mA
71-95V
123V
88%
LGEU100-CV12
8300mA
9-12V
15V
88%
LGEU80-CV36
2200mA
25-36V
46V
90%
LGEU100-CV71
1400mA
53-71V
92V
88%
LGEU80-CV24
3400mA
17-24V
31V
90%
LGEU100-CV48
2100mA
36-48V
62V
88%
LGEU80-CV12
5500mA
8.4-12V
15V
90%
LGEU100-CV36
2800mA
27-36V
46V
88%
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/230VAC (70%~100% full load)
INPUT CURRENT
0.42A/230VAC
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (full load)
INPUT CURRENT
INRUSH CURRENT
1.2A/110VAC, 0.6A/220VAC
COLD START, 35A/230VAC
INRUSH CURRENT
COLD START, 65A/230VAC
OUTPUT CURRENT ADJUSTABLE
60%~100%
OUTPUT CURRENT ADJUSTABLE
60%~100%
OUTPUT VOLTAGE ADJUSTABLE
±10%
OUTPUT VOLTAGE ADJUSTABLE
±10%
LINE REGULATION
±1%
LINE REGULATION
±1%
LOAD REGULATION
±3%
LOAD REGULATION
±3%
SETUP, RISE TIME
2S at full load (cold start, power on)
SETUP, RISE TIME
1S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
MTBF, LIFE TIME
400K hours typ. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
400K hours typ. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
SAFETY
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 870g
Weight: 950g
LGE SERIES
INPUT
LGE SERIES
SPECIFICATIONS
MODELS
CHARACTERISTICS
74
100W
80~250W LED Driver with Adjustable Output Current
75
LGE SERIES
LGE SERIES
150W
SPECIFICATIONS
80~250W LED Driver with Adjustable Output Current
FEATURES
FEATURES
> Universal Input: 90~305Vac
> All-round Protection: SCP,
> Adjustable Output Current 60%~100% OVP, OTP
> High PF up to 0.99
> Optional Dimming (0~10V,
> 5 Year Warranty
PWM)
> IP65 for Outdoor Lighting
> Universal Input: 90~305Vac
> All-round Protection: SCP,
> Adjustable Output Current 60%~100% OVP, OTP
> High PF up to 0.99
> Optional Dimming (0~10V,
> 5 Year Warranty
PWM)
> IP65 for Outdoor Lighting
Constant Current / Constant Voltage
Constant Current / Constant Voltage
MODELS
Model ①
Output-C
Output-V
VNO-LOAD EFF(typ.)
Model ①
Output-C
Output-V
VNO-LOAD EFF(typ.)
Model ①
Output-C
Output-V
VNO-LOAD EFF(typ.)
Model ①
Output-C
Output-V
VNO-LOAD EFF(typ.)
LGEU150-CV214
700mA
160-214V
278V
88%
LGEU150-CV48
3150mA
36-48V
62V
88%
LGEU200-CV143
1400mA
114-143V
278V
90%
LGEU200-CV63
3150mA
50-63V
81V
90%
LGEU150-CV142
1050mA
107-143V
185V
88%
LGEU150-CV42
3500mA
32-43V
55V
88%
LGEU200-CV114
1750mA
91-114V
185V
90%
LGEU200-CV57
3500mA
46-57V
74V
90%
LGEU150-CV107
1400mA
80-107V
139V
88%
LGEU150-CV36
4200mA
27-36V
46V
88%
LGEU200-CV95
2100mA
76-95V
139V
90%
LGEU200-CV48
4200mA
38-48V
62V
90%
LGEU150-CV71
2100mA
53-71V
92V
88%
LGEU150-CV24
6250mA
18-24V
31V
88%
LGEU200-CV83
2400mA
67-83V
92V
90%
LGEU200-CV36
5500mA
29-36V
46V
90%
LGEU150-CV54
2800mA
40-54V
70V
88%
LGEU200-CV71
2800mA
57-71V
70V
90%
LGEU200-CV24
8300mA
18-24V
31V
90%
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/220VAC (full load)
INPUT CURRENT
1.6A/110VAC, 0.75A/220VAC
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/230VAC(70~100% full load)
INPUT CURRENT
INRUSH CURRENT
1.2A/230VAC
COLD START, 65A/230VAC
INRUSH CURRENT
COLD START, 65A/230VAC
OUTPUT CURRENT ADJUSTABLE
60%~100%
OUTPUT CURRENT ADJUSTABLE
60%~100%
OUTPUT VOLTAGE ADJUSTABLE
±10%
OUTPUT VOLTAGE ADJUSTABLE
±10%
LINE REGULATION
±1%
LINE REGULATION
±1%
LOAD REGULATION
±3%
LOAD REGULATION
±3%
SETUP, RISE TIME
1S at full load (cold start, power on)
SETUP, RISE TIME
2S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
MTBF, LIFE TIME
400K hours typ. refer to MIL-HDBK-217F (25°C)
MTBF, LIFE TIME
400K hours typ. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
SAFETY
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 950g
Weight: 1050g
LGE SERIES
INPUT
LGE SERIES
SPECIFICATIONS
MODELS
CHARACTERISTICS
76
200W
80~250W LED Driver with Adjustable Output Current
77
LGE SERIES
250W
SPECIFICATIONS
80~250W LED Driver with Adjustable Output Current
Frequently Asked Questions
on LED Drivers
FEATURES
> Universal Input: 90~305Vac
> All-round Protection: SCP,
> Adjustable Output Current 60%~100% OVP, OTP
> High PF up to 0.99
> Optional Dimming (0~10V,
> 5 Year Warranty
PWM)
> IP65 for Outdoor Lighting
Constant Current (CC) LED Drivers
Constant Current / Constant Voltage
MODELS
Model①
Output-C
Output-V
VNO-LOAD
EFF(typ.)
Model ①
Output-C
Output-V
VNO-LOAD
EFF(typ.)
LGEU250-CV179
1400mA
143-179V
232V
90%
LGEU250-CV79
3150mA
63-79V
102V
90%
LGEU250-CV143
1750mA
114-143V
185V
90%
LGEU250-CV72
3500mA
58-72V
93V
90%
LGEU250-CV119
2100mA
95-119V
154V
90%
LGEU250-CV60
4200mA
48-60V
78V
90%
LGEU250-CV102
2450mA
82-102V
132V
90%
LGEU250-CV50
5000mA
40-50V
65V
90%
LGEU250-CV89
2800mA
71-89V
115V
90%
LGEU250-CV24
8300mA
19-24V
31V
90%
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
VOLTAGE RANGE, FREQUENCY
90-305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.99/110VAC, 0.96/230VAC(70~100% full load)
INPUT CURRENT
1.4A/230VAC
INRUSH CURRENT
COLD START, 65A/230VAC
OUTPUT CURRENT ADJUSTABLE
60%~100%
OUTPUT VOLTAGE ADJUSTABLE
±10%
LINE REGULATION
±1%
LOAD REGULATION
±3%
SETUP, RISE TIME
2S at full load (cold start, power on)
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-150% Vout, the driver shall return to normal operation after the power is turn-on again
OPERATING
Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing
STORAGE
Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH
SAFETY STANDARDS
Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13
EMC
Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4,
EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547
MTBF, LIFE TIME
400K hours typ. refer to MIL-HDBK-217F (25°C)
CC LED drivers are designed to maintain a Constant Current during operation. A CC LED driver
balances the output current from each channel
to ensure reduced EMI interference and maintain the long lifetime of LEDs. The CC LED
driver circuit allows the driver to operate in the
‘constant current region’ also ensuring there is
no variation in the brightness of the LEDs. This
means you do not have to use resistors or control the current being fed to the LEDs so they
can be used in series as long as the forward
voltage is within the specified output range of
the LED power driver.
Constant Voltage (CV) LED Drivers
① Add suffix for dimming option, “D” (0~10V), “P” (PWM)
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC
CV LED drivers are designed to maintain a Constant Voltage during operation regardless of the
current variations between 0-100%. A CV LED
driver is ideal for paralleled LED lighting arrays
because they generically have an in built resistor to control the current, therefore a CV driver
would be required to convert the AC power to
the required DC voltage.
LGE SERIES
MECHANICAL SPECIFICATION
Dimensions in mm
Weight: 1200g
What is the Difference between
Constant Voltage (CV) and Constant
Current (CC) Drivers?
With Constant Voltage the LED module only
requires a fixed voltage often 12VDC or
24VDC. The current is usually regulated by
either resistors that have been wired in series
78
with the LEDs or by an on board/built in regulator that the LED module may have.
CV loads may be added in parallel across the
output of the driver until the maximum output
current is reached.
This arrangement is often used in installations
where the number of LED modules being connected is unknown however may provide inconsistent Led performance and reduced life.
With Constant Current the reverse is true. The
current is fixed by the driver whilst the voltage
will vary depending on the load. The more LEDs
that are attached the higher the output voltage
will be up to a maximum set by the driver. This
can provide uniform brightness and color behavior of the LEDs with no negative impact on
LED Lifetime.
How will I Know whether to Use a
Constant Voltage or Constant
Current Driver with my LEDs?
Usually the manufacturer of the LED module
will specify whether it is for use with either a
Constant Voltage or Constant Current driver.
You cannot run an LED module designed for CC
from a CV supply without damaging it. However
a CV LED load will run (albeit inefficiently) from
a CC driver. Another indication is if the LED
module is rated in milliamps (mA) or volts (V).
Milliamps indicates a CC driver and Volts
means a CV driver is required.
79
Frequently Asked Questions
on LED Drivers
Frequently Asked Questions
on LED Drivers
What are PF and PFC?
What are the Differences between
MTBF and Lifetime?
What is 0-10V/1-10V Dimming?
Mean Time Between Failure (MTBF) represents
the statistical approximation of the cumulative
hours a number of units should operate before
a failure can be expected. It does not represent
the expected life of any given unit.
Used as an early fluorescent dimming system
and still used today, 0-10V(1-10V) dimming
has been adapted to become a reliable LED
dimming control protocol.
0-10 V is one of the earliest and simplest electronic lighting control signaling systems; simply
put, the control signal is a DC voltage that
varies between zero and ten volts. The controlled lighting should scale its output so that
at 10 V, the controlled light should be at 100%
of its potential output, and at 0 V it should at
the lowest possible dimming level.
Power Factor (abbreviated PF) is the ratio of
real power to apparent power in an AC power
system and is expressed as a number between
0 and 1. Real power is the actual power drawn
by the load whereas apparent power is the
product of the load current and load voltage.
Since the voltage and current may be out of
phase this product may be significantly greater
than the real power.
First Number
0-No protection
1-Protected against solid objects
2-Protected against solid objects
3-Protected against solid objects
4-Protected against solid objects
5-Protected against dust, limited
harmful deposit)
6-Totally protected against dust
up to 50mm³
up to 12mm³
up to 2.5mm³
up to 1mm³
ingress (no
Second Number
PFC is the abbreviation for Power Factor Correction. In order to maintain a high power
factor, switch mode power supplies (including
LED drivers) must employ some form of power
factor correction. This is an important issue because a load with a low power factor draws
more current than a load with a high power
factor for the same amount of real power
transferred. Low power factor therefore results
in greater power losses in the utility lines.
What does IP67 Mean?
IP stands for 'Ingress Protection'
An IP number is used to specify the environmental protection of enclosures around electronic equipment. These ratings are determined
by specific tests.
The IP number is composed of two numbers,
the first referring to the protection against solid
objects and the second against liquids. The
higher the number, the better the protection.
80
0-No protection
1-Protection against vertically falling drops of
water (e.g. condensation)
2-Protection against direct sprays of water up to
15 degrees from vertical
3-Protection against direct sprays of water up to
60 degrees from vertical
4-Protection against water sprayed from all
directions - limited ingress permitted
5-Protected against low pressure jets of water
from all directions - limited ingress permitted
6-Protected against low pressure jets of water,
limited ingress permitted (e.g. ship deck)
7-Protected against the effect of immersion be
tween 15cm and 1m
8-Protected against long periods of immersion
under pressure
The lifetime of a product indicates how long a
product should be expected to survive under
normal operating conditions. It is the period of
time between starting to use the device and
the beginning of the wear-out phase. This is
determined by the life expectancy of components used in assembly of the unit. The weakest component with the shortest life expectancy determines the life of the whole product.
For power supplies, electrolytic capacitors typically have the shortest lifetime expectancy.
MTBF is applicable only during the normal operating life of the product.
What is THD(Total Harmonic
Distortion)?
The total harmonic distortion, or THD, of a
signal is a measurement of the harmonic distortion present and is defined as the ratio of
the sum of the powers of all harmonic components to the power of the fundamental frequency. THD is used to characterize the linearity of audio systems and the power quality of
electric power systems. Distortion factor is a
closely related term, sometimes used as a synonym.
In power systems, lower THD means reduction
in peak currents, heating, emissions, and core
loss in motors
What is PWM (Pulse Width
Modulation) Dimming?
A method most LED Drivers use to regulate the
amount of power to the LED. PWM turns LEDs
on and off at high frequency, reducing the total
ON time to achieve a desired dimming level
without visible flicker. PWM signals are sent