TECHNOLOGY SHORT CIRCUIT COMPACT PWM DIMMING EFFICIENCY CONSTANT CURRENT OUTDOOR APPLICATION ACTIVE PFC QUALITY ALL-ROUND PROTECTION LED POWER SUPPLIES GOOD PERFORMANCE STREET LIGHTING DESIGN PAIRUI POWER SUPPLIES CONSTANT VOLTAGE MTBF SAFETY UNIVERSAL INPUT TEMPERATURE FACTORY SPECIFICATION WARRANTY 0-10V DIMMING INDOOR APPLICATION NO MOQ LIMIT LOW RIPPLE EMC STANDARDS LIFE TIME Sales Office #1518 Dexin Mansion, No. 545 Museum Road, Yangzhou City, Jiangsu, China 225009 E-mail: [email protected] Tel: +86 (514) 8279 1592 w w w. p a i r u i g r o u p . c o m Factory Location No. 286 People East Road, Renhe Town, Tianchang City, Anhui, China 239331 Tel: +86 (550) 7814 888 Fax: +86 (550) 7931 133 RoHS REACH LED Power Supplies PAIRUI Group Inc. INDOOR LIGHTING PAIRUI GROUP INC. is a vertically integrated group company focused on designing and manufacturing of power supplies. The group consists of power supply manufacturers, and upstream manufacturers of transformers, inductors, magnetic cores and plastic parts, all under the same ownership. Most important benefits from the integration include cost reduction and flexibility. As a result, PAIRUI is able to offer power supply products with very competitive price, and design unique products to fit the most demanding needs. For more than 30 years cultivated in this industry, PAIRUI's goal is to be your trusted power partner. OUTDOOR LIGHTING 20~40W 8~40W LZ SERIES PAGE 2-7 LC SERIES 20~150W 10~50W LX SERIES PAGE 8-15 LE/LF SERIES PAGE 16-23 LG/LGS SERIES 8~40W LN SERIES PAGE 24-29 PAGE 30-35 PAGE 52-67 LED POWER SUPPLIES POWER CONVERTERS DEDICATED POWER SOLUTIONS 100~150W LGC SERIES 12~35W LS SERIES PAGE 40-51 30~250W 20~60W LL SERIES PAGE 36-39 PAGE 68-71 80~250W LGE SERIES PAGE 72-78 1 LZ SERIES 8~40W LED Driver with Low Cost MODEL NUMBER STRUCTURE LZ B 25 - C 350 R Ripple Blank = High Ripple R = Low Ripple * Not available for 8/12W Model Output Parameter CC type: Output Current(mA) CV type: Output Voltage(Vdc) * Not yet available in this series Output Type C = Constant current type V = Constant voltage type * Not yet available in this series Maximum Output Power (W) Input Voltage Range U = Universal(90~264VAC) A = 115VAC(90-132VAC) * Not yet available in this series B = 230VAC(180-264VAC) Series Name FEATURES 3 Year Warranty Constant Current Output Active Power Factor Correction, Class II Power Universal Input Voltage and High Input Voltage Selectable Short Circuit and Over Voltage Protections Safety Standards: Design Refer to EN61347-1, EN61347-2-13 EMC Standards: Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 2 APPLICATIONS Indoor Lighting Spot Lighting Recessed Lighting SERIES OVERVIEW Cabinet Lighting SERIES VIN OUTPUT (CC) CASE Down Lighting LZ[ ]8-C 90-264VAC/180-264VAC 240, 350, 500, 700mA 95.5 x 32.5 x 21.5 mm LZB12-C 180-264VAC 240, 350, 500, 700mA 95.5 x 32.5 x 21.5 mm LZ[ ]18-C 90-264VAC/180-264VAC 350, 500, 700, 1050mA 130 x 42 x 24.5 mm LZ[ ]25-C 90-264VAC/180-264VAC 350, 500, 700, 1050mA 130 x 42 x 24.5 mm LZ[ ]40-C 90-264VAC/180-264VAC 350, 500, 700, 1050mA 137.5 x 45 x 28.5 mm SAFETY APPROVAL 3 SPECIFICATIONS 8~40W LED Driver with Built-in Active PFC LZ SERIES LZ SERIES 8W/12W FEATURES FEATURES > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Active Power Factor Correction > Short Circuit, Over Voltage Protections > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Active Power Factor Correction > Short Circuit, Over Voltage Protections Constant Current Constant Current MODELS SPECIFICATIONS MODELS Model Output TOL. RIPPLE EFF(typ.) Model Output TOL. RIPPLE EFF(typ.) Model Output TOL. RIPPLE EFF(typ.) Model Output TOL. RIPPLE EFF(typ.) LZ[ ]8-C240 240mA (23-33V) ±5% 50% 80% LZB12-C240 240mA (25-50V) ±5% 50% 80% LZ[ ]18-C350 350mA (26-52V) ±5% 50% 85% LZ[ ]18-C350R 350mA (26-52V) ±5% 5% 85% LZ[ ]8-C350 350mA (16-23V) ±5% 50% 80% LZB12-C350 350mA (18-36V) ±5% 50% 80% LZ[ ]18-C500 500mA (25-36V) ±5% 50% 85% LZ[ ]18-C500R 500mA (25-36V) ±5% 5% 85% LZ[ ]8-C500 500mA(11-16V) ±5% 50% 80% LZB12-C500 500mA (17-24V) ±5% 50% 80% LZ[ ]18-C700 700mA (17-34V) ±5% 50% 85% LZ[ ]18-C700R 700mA (17-34V) ±5% 5% 85% LZ[ ]8-C700 700mA (9-12V) ±5% 50% 80% LZB12-C700 700mA (9-18V) ±5% 50% 80% LZ[ ]18-C1050 1050mA (13-26V) ±5% 50% 85% LZ[ ]18-C1050R 1050mA (13-26V) ±5% 5% 85% * [ ]= U or B, U(90~264VAC), B(180~264VAC) * [ ]= U or B, U(90~264VAC), B(180~264VAC) CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY * [ ]= U or B, U(90~264VAC), B(180~264VAC) CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 8W: 90-264VAC/180-264VAC, 47~63Hz; 12W: 180-264VAC, 47-63Hz VOLTAGE RANGE, FREQUENCY 90-264VAC/180-264VAC, 47~63Hz POWER FACTOR (Typ.) 8W: 0.9/220VAC; 12W: 0.95/220VAC (70%~100% full load) INPUT CURRENT (Typ.) 8W: 0.1A/230VAC; 12W: 0.15A/230VAC POWER FACTOR (Typ.) 0.95/220VAC (70%~100% full load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.15A/230VAC 8W: COLD START, 20A/230VAC; 12W: COLD START, 35A/230VAC INRUSH CURRENT (Typ.) COLD START, 35A/230VAC LINE REGULATION 5% LINE REGULATION 5% LOAD REGULATION 5% LOAD REGULATION 5% SETUP, RISE TIME 2S at full load (cold start, power on) SETUP, RISE TIME 2S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC MECHANICAL SPECIFICATION 4 18W 8~40W LED Driver with Built-in Active PFC LZ SERIES LZ SERIES MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 75g Weight: 115g 5 SPECIFICATIONS 8~40W LED Driver with Built-in Active PFC LZ SERIES LZ SERIES 25W FEATURES FEATURES > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Active Power Factor Correction > Short Circuit, Over Voltage Protections > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Active Power Factor Correction > Short Circuit, Over Voltage Protections Constant Current Constant Current MODELS SPECIFICATIONS MODELS Model Output TOL. RIPPLE EFF(typ.) Model Output TOL. RIPPLE EFF(typ.) Model Output TOL. RIPPLE EFF(typ.) Model Output TOL. RIPPLE EFF(typ.) LZ[ ]25-C350 350mA (43-72V) ±5% 50% 85% LZ[ ]25-C350R 350mA (43-72V) ±5% 5% 85% LZ[ ]40-C350 350mA (66-110V) ±5% 50% 85% LZ[ ]40-C350R 350mA (66-110V) ±5% 5% 85% LZ[ ]25-C500 500mA (35-50V) ±5% 50% 85% LZ[ ]25-C500R 500mA (35-50V) ±5% 5% 85% LZ[ ]40-C500 500mA (56-80V) ±5% 50% 85% LZ[ ]40-C500R 500mA (56-80V) ±5% 5% 85% LZ[ ]25-C700 700mA (22-36V) ±5% 50% 85% LZ[ ]25-C700R 700mA (22-36V) ±5% 5% 85% LZ[ ]40-C700 700mA (34-57V) ±5% 50% 85% LZ[ ]40-C700R 700mA (34-57V) ±5% 5% 85% LZ[ ]25-C1050 1050mA (15-24V) ±5% 50% 85% LZ[ ]25-C1050R 1050mA (15-24V) ±5% 5% 85% LZ[ ]40-C1050 1050mA (23-39V) ±5% 50% 85% LZ[ ]40-C1050R 1050mA (23-39V) ±5% 5% 85% * [ ]= U or B, U(90~264VAC), B(180~264VAC) * [ ]= U or B, U(90~264VAC), B(180~264VAC) * [ ]= U or B, U(90~264VAC), B(180~264VAC) CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY * [ ]= U or B, U(90~264VAC), B(180~264VAC) CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC/180-264VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-264VAC/180-264VAC, 47~63Hz POWER FACTOR (Typ.) 0.95/220VAC (70%~100% full load) INPUT CURRENT (Typ.) 0.15A/230VAC POWER FACTOR (Typ.) 0.95/220VAC (70%~100% full load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.25A/230VAC COLD START, 35A/230VAC INRUSH CURRENT (Typ.) COLD START, 35A/230VAC LINE REGULATION 5% LINE REGULATION 5% LOAD REGULATION 5% LOAD REGULATION 5% SETUP, RISE TIME 2S at full load (cold start, power on) SETUP, RISE TIME 2S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=200~240VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=200~240VAC MECHANICAL SPECIFICATION 6 40W 8~40W LED Driver with Built-in Active PFC LZ SERIES LZ SERIES MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 120g Weight: 160g 7 LX SERIES 10~50W LED Driver with Built-in PFC MODEL NUMBER STRUCTURE LX U 30 - C 350 D Dimming Option Blank = Without dimming D = With 0~10V dimming Output Parameter CC type: Output Current(mA) CV type: Output Voltage(Vdc) * Not yet available in this series Output Type C = Constant current type V = Constant voltage type * Not yet available in this series Maximum Output Power (W) Input Voltage Range U = Universal (90~264VAC) Series Name FEATURES 3 Year Warranty Constant Current Output Active Power Factor Correction, Class II Power Universal Input Voltage 90~264Vac Short Circuit and Over Voltage Protections Safety Standards: Design refer to EN61347-1, EN61347-2-13 EMC Standards: Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 8 APPLICATIONS Indoor Lighting SERIES OVERVIEW Spot Lighting SERIES VIN OUTPUT (CC) CASE LXU10-C(D) 90~264VAC 240, 350, 700mA 70 x 43 x 30 mm LXU15-C(D) 90~264VAC 240, 350, 700mA 70 x 43 x 30 mm LXU30-C(D) 90~264VAC 350, 700, 1050mA 97 x 43 x 30 mm LXU40-C(D) 90~264VAC 350, 700, 1050mA 122 x 43 x 30 mm LXU45-C(D) 90~264VAC 350, 700, 1050mA 122 x 43 x 30 mm LXU50-C(D) 90~264VAC 350, 700, 1050mA 122 x 43 x 30 mm Recessed Lighting Cabinet Lighting Down Lighting SAFETY APPROVAL 9 SPECIFICATIONS 10~50W LED Driver with Built-in PFC LX SERIES LX SERIES 10W FEATURES FEATURES > 3 Year Warranty > Constant Current Output > Class II Power > Active Power Factor Correction > Short Circuit, Over Voltage Protections > 3 Year Warranty > Constant Current Output > Class II Power > Active Power Factor Correction > Short Circuit, Over Voltage Protections Constant Current Constant Current MODELS SPECIFICATIONS MODELS Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) LXU10-C240 240mA (25-42V) ±5% 40% 85% LXU10-C240D 240mA (25-42V) ±5% 40% 85% LXU15-C240 240mA (37-62V) ±5% 40% 85% LXU15-C240D 240mA (37-62V) ±5% 40% 85% LXU10-C350 350mA (17-29V) ±5% 40% 85% LXU10-C350D 350mA (17-29V) ±5% 40% 85% LXU15-C350 350mA (26-42V) ±5% 40% 85% LXU15-C350D 350mA (26-42V) ±5% 40% 85% LXU10-C700 700mA (9-14V) ±5% 40% 85% LXU10-C700D 700mA (9-14V) ±5% 40% 85% LXU15-C700 700mA (13-21V) ±5% 40% 85% LXU15-C700D 700mA (13-21V) ±5% 40% 85% * Above models which have suffix “D” are all with 0-10V dimming CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY * Above models which have suffix “D” are all with 0-10V dimming CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz POWER FACTOR 0.9/230VAC (70%~100% full load) INPUT CURRENT 0.1A/230VAC POWER FACTOR 0.9/230VAC (70%~100% full load) INPUT CURRENT LEAKAGE CURRENT 0.15A/230VAC 0.75mA/230VAC LEAKAGE CURRENT 0.75mA/230VAC INRUSH CURRENT COLD START, 15A/230VAC at full load INRUSH CURRENT COLD START, 15A/230VAC at full load LINE REGULATION ±3% LINE REGULATION ±3% LOAD REGULATION ±3% LOAD REGULATION ±3% SETUP, RISE TIME 1.5S at full load (cold start, power on) SETUP, RISE TIME 1.5S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing OPERATING Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC MECHANICAL SPECIFICATION 10 15W 10~50W LED Driver with Built-in PFC LX SERIES LX SERIES MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 130g Weight: 130g 11 SPECIFICATIONS 10~50W LED Driver with Built-in PFC LX SERIES LX SERIES 30W FEATURES FEATURES > 3 Year Warranty > Constant Current Output > Class II Power > Active Power Factor Correction > Short Circuit, Over Voltage Protections > 3 Year Warranty > Constant Current Output > Class II Power > Active Power Factor Correction > Short Circuit, Over Voltage Protections Constant Current Constant Current MODELS SPECIFICATIONS MODELS Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) LXU30-C350 350mA (60-86V) ±5% 40% 89% LXU30-C350D 350mA (60-86V) ±5% 40% 89% LXU40-C350 350mA (80-114V) ±5% 40% 89% LXU40-C350D 350mA (80-114V) ±5% 40% 89% LXU30-C700 700mA (30-43V) ±5% 40% 88% LXU30-C700D 700mA (30-43V) ±5% 40% 88% LXU40-C700 700mA (40-58V) ±5% 40% 88% LXU40-C700D 700mA (40-58V) ±5% 40% 88% LXU30-C1050 1050mA (20-29V) ±5% 40% 86% LXU30-C1050D 1050mA (20-29V) ±5% 40% 86% LXU40-C1050 1050mA (27-38V) ±5% 40% 86% LXU40-C1050D 1050mA (27-38V) ±5% 40% 86% * Above models which have suffix “D” are all with 0-10V dimming CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY * Above models which have suffix “D” are all with 0-10V dimming CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz POWER FACTOR 0.9/230VAC (70%~100% full load) INPUT CURRENT 0.2A/230VAC POWER FACTOR 0.92/230VAC (70%~100% full load) INPUT CURRENT LEAKAGE CURRENT 0.3A/230VAC 0.75mA/230VAC LEAKAGE CURRENT 0.75mA/230VAC INRUSH CURRENT COLD START, 25A/230VAC at full load INRUSH CURRENT COLD START, 35A/230VAC at full load LINE REGULATION ±3% LINE REGULATION ±3% LOAD REGULATION ±3% LOAD REGULATION ±3% SETUP, RISE TIME 1.5S at full load (cold start, power on) SETUP, RISE TIME 1.5S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing OPERATING Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC MECHANICAL SPECIFICATION 12 40W 10~50W LED Driver with Built-in PFC LX SERIES LX SERIES MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 250g Weight: 270g 13 SPECIFICATIONS 10~50W LED Driver with Built-in PFC LX SERIES LX SERIES 45W FEATURES FEATURES > 3 Year Warranty > Constant Current Output > Class II Power > Active Power Factor Correction > Short Circuit, Over Voltage Protections > 3 Year Warranty > Constant Current Output > Class II Power > Active Power Factor Correction > Short Circuit, Over Voltage Protections Constant Current Constant Current MODELS SPECIFICATIONS MODELS Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) Model Output TOL. Ripple EFF(typ.) LXU45-C350 350mA (90-129V) ±5% 40% 89% LXU45-C350D 350mA (90-129V) ±5% 40% 89% LXU50-C350 350mA (100-142V) ±5% 40% 89% LXU50-C350D 350mA (100-142V) ±5% 40% 89% LXU45-C700 700mA (46-65V) ±5% 40% 88% LXU45-C700D 700mA (46-65V) ±5% 40% 88% LXU50-C700 700mA (50-71V) ±5% 40% 88% LXU50-C700D 700mA (50-71V) ±5% 40% 88% LXU45-C1050 1050mA (30-43V) ±5% 40% 86% LXU45-C1050D 1050mA (30-43V) ±5% 40% 86% LXU50-C1050 1050mA (33-48V) ±5% 40% 86% LXU50-C1050D 1050mA (33-48V) ±5% 40% 86% * Above models which have suffix “D” are all with 0-10V dimming CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY * Above models are all with 0-10V dimming CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz POWER FACTOR 0.92/230VAC (70%~100% full load) INPUT CURRENT 0.4A/230VAC POWER FACTOR 0.92/230VAC (70%~100% full load) INPUT CURRENT LEAKAGE CURRENT 0.45A/230VAC 0.75mA/230VAC LEAKAGE CURRENT 0.75mA/230VAC INRUSH CURRENT COLD START, 35A/230VAC at full load INRUSH CURRENT COLD START, 35A/230VAC at full load LINE REGULATION ±3% LINE REGULATION ±3% LOAD REGULATION ±3% LOAD REGULATION ±3% SETUP, RISE TIME 1.5S at full load (cold start, power on) SETUP, RISE TIME 1.5S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing OPERATING Temperature -20°C ~ +50°C, Humidity 20 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC MECHANICAL SPECIFICATION 14 50W 10~50W LED Driver with Built-in PFC LX SERIES LX SERIES MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 270g Weight: 300g 15 LL SERIES 20~60W Isolated LED Driver for Commercial LED Lighting MODEL NUMBER STRUCTURE LL M U 20 - C 500 A Dimming Option Blank = No dimming A = 3 in 1 dimming(0~10V, PWM, Resistor) Output Parameter CC type: Output Current(mA) CV type: Output Voltage(Vdc) * Not yet available in this series Output Type C = Constant current type V = Constant voltage type * Not yet available in this series Maximum Output Power (W) Input Voltage Range U = Universal(90-305VAC) Output Voltage Range M = 27-40VDC N = 35-55VDC Series Name FEATURES 3 Year Warranty Constant Current Output Active Power Factor Correction 3 in 1 Dimming(0~10V, PWM, Resistor) Can be Used for Lighting Equipment in Protection Class I and II Short Circuit and Over Voltage Protections APPLICATIONS Indoor Lighting Strip Lighting Wall Lighting SERIES OVERVIEW Cabinet Lighting SERIES VIN OUTPUT (CC) CASE Tri-Proof Lighting LL[ ]20-C (A) 90~305VAC 300, 350, 400, 450, 500, 550mA 245 x 30 x 21 mm SAFETY APPROVAL LL[ ]40-C (A) 90~305VAC 500, 600, 700, 750, 800, 900, 950, 1000mA 285 x30 x 21 mm LL[ ]60-C (A) 90~305VAC 1200, 1300, 1400, 1500, 1550mA 355 x30 x 21 mm Safety Standards: Design Refer to EN61347-1, EN61347-2-13 EMC Standards: Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 16 17 LL SERIES LL SERIES 20W SPECIFICATIONS 20~60W Isolated LED Driver for Commercial LED Lighting FEATURES > Active Power Factor Correction > Can be Used for Lighting Equipment in Protection Class I and II > No Flickering > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Short Circuit, Over Voltage Protections Constant Current > 3 in 1 Dimming(0~10V, PWM, Resistor) > Active Power Factor Correction > Can be Used for Lighting Equipment in Protection Class I and II Constant Current MODELS Model Output TOL. Power EFF(typ.) Model Output TOL. Power EFF(typ.) Model Output TOL. Power EFF(typ.) Model Output TOL. Power EFF(typ.) LLMU20-C350 350mA (27-40V) ±5% 14W 83% LLNU20-C300 300mA(35-55V) ±5% 16.5W 84% LLMU20-C350A 350mA(27-40V) ±5% 14W 84% LLNU20-C300A 300mA(35-55V) ±5% 16.5W 85% LLMU20-C400 400mA (27-40V) ±5% 16W 85% LLNU20-C350 350mA(35-55V) ±5% 19.25W 86% LLMU20-C400A 400mA(27-40V) ±5% 16W 84% LLNU20-C350A 350mA(35-55V) ±5% 19.25W 85% LLMU20-C450 450mA (27-40V) ±5% 18W 86% LLNU20-C400 400mA(35-55V) ±5% 22W 86% LLMU20-C450A 450mA(27-40V) ±5% 18W 86% LLNU20-C400A 400mA(35-55V) ±5% 22W 86% LLMU20-C500 500mA (27-40V) ±5% 20W 86% LLMU20-C500A 500mA(27-40V) ±5% 20W 86% LLMU20-C550 550mA (27-40V) ±5% 22W 86% LLMU20-C550A 550mA(27-40V) ±5% 22W 86% CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY LL SERIES MODELS LL SERIES SPECIFICATIONS FEATURES > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Short Circuit, Over Voltage Protections CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90~305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90~305VAC, 47~63Hz POWER FACTOR (Typ.) 0.95/230VAC (70%~100% full load) INPUT CURRENT (Typ.) 0.4A/230VAC POWER FACTOR (Typ.) 0.95/230VAC (70%~100% full load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.4A/230VAC COLD START, 60A/230VAC INRUSH CURRENT (Typ.) COLD START, 60A/230VAC LINE REGULATION ±5% LINE REGULATION ±5% LOAD REGULATION ±5% LOAD REGULATION ±5% SETUP, RISE TIME ≤1S at full load (cold start, power on) SETUP, RISE TIME ≤1S at full load (cold start, power on) RIPPLE <1V RIPPLE <4V SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 110-130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing OPERATING Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC MECHANICAL SPECIFICATION 18 20W 20~60W Isolated LED Driver for Commercial LED Lighting MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 140g Weight: 145g 19 LL SERIES LL SERIES 40W SPECIFICATIONS 20~60W Isolated LED Driver for Commercial LED Lighting FEATURES > Active Power Factor Correction > Can be Used for Lighting Equipment in Protection Class I and II > No Flickering > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Short Circuit, Over Voltage Protections Constant Current > 3 in 1 Dimming(0~10V, PWM, Resistor) > Active Power Factor Correction > Can be Used for Lighting Equipment in Protection Class I and II Constant Current MODELS Model Output TOL. Power EFF(typ.) Model Output TOL. Power EFF(typ.) Model Output TOL. Power EFF(typ.) Model Output TOL. Power EFF(typ.) LLMU40-C600 600mA (27-40V) ±5% 24W 85% LLMU40-C1000 1000mA (27-40V) ±5% 40W 85% LLMU40-C600A 600mA (27-40V) ±5% 24W 85% LLMU40-C1000A 1000mA (27-40V) ±5% 40W 86% LLMU40-C700 700mA (27-40V) ±5% 28W 85% LLNU40-C500 500mA (35-55V) ±5% 27.5W 85% LLMU40-C700A 700mA (27-40V) ±5% 28W 85% LLNU40-C500A 500mA (35-55V) ±5% 27.5W 86% LLMU40-C800 800mA (27-40V) ±5% 32W 85% LLNU40-C600 600mA (35-55V) ±5% 33W 85% LLMU40-C800A 800mA (27-40V) ±5% 32W 85% LLNU40-C600A 600mA (35-55V) ±5% 33W 86% LLMU40-C900 900mA (27-40V) ±5% 36W 85% LLNU40-C750 750mA (35-55V) ±5% 41.25W 85% LLMU40-C900A 900mA (27-40V) ±5% 36W 85% LLNU40-C750A 750mA (35-55V) ±5% 41.25W 86% LLMU40-C950 950mA (27-40V) ±5% 38W 85% LLMU40-C950A 950mA (27-40V) ±5% 38W 86% CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY LL SERIES MODELS LL SERIES SPECIFICATIONS FEATURES > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Short Circuit, Over Voltage Protections CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90~305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90~305VAC, 47~63Hz POWER FACTOR (Typ.) 0.94/230VAC (70%~100% full load) INPUT CURRENT (Typ.) 0.7A/230VAC POWER FACTOR (Typ.) 0.94/230VAC (70%~100% full load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.4A/230VAC COLD START, 60A/230VAC INRUSH CURRENT (Typ.) COLD START, 60A/230VAC LINE REGULATION ±5% LINE REGULATION ±5% LOAD REGULATION ±5% LOAD REGULATION ±5% SETUP, RISE TIME ≤1S at full load (cold start, power on) SETUP, RISE TIME ≤1S at full load (cold start, power on) RIPPLE <2V RIPPLE <4V SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 110-130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing OPERATING Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC MECHANICAL SPECIFICATION 20 40W 20~60W Isolated LED Driver for Commercial LED Lighting MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 195g Weight: 200g 21 LL SERIES 20~60W Isolated LED Driver for Commercial LED Lighting LL SERIES 60W SPECIFICATIONS FEATURES > Active Power Factor Correction > Can be Used for Lighting Equipment in Protection Class I and II > No Flickering > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Short Circuit, Over Voltage Protections Constant Current MODELS Output TOL. Power EFF(typ.) Model Output TOL. Power EFF(typ.) LLMU60-C1200 1200mA (27-40V) ±5% 48W 86% LLMU60-C1200A 1200mA (27-40V) ±5% 48W 86% LLMU60-C1300 1300mA (27-40V) ±5% 52W 86% LLMU60-C1300A 1300mA (27-40V) ±5% 52W 86% LLMU60-C1400 1400mA (27-40V) ±5% 56W 86% LLMU60-C1400A 1400mA (27-40V) ±5% 56W 86% LLMU60-C1500 1500mA (27-40V) ±5% 60W 86% LLMU60-C1500A 1500mA (27-40V) ±5% 60W 86% LLMU60-C1550 1550mA (27-40V) ±5% 62W 86% LLMU60-C1550A 1550mA (27-40V) ±5% 62W 86% CHARACTERISTICS PROTECTION ENVIRONMENT SAFETY LL SERIES LL SERIES > 3 in 1 Dimming(0~10V, PWM, Resistor) > Active Power Factor Correction > Can be Used for Lighting Equipment in Protection Class I and II Model OUTPUT SPECIFICATIONS Constant Current MODELS INPUT 60W FEATURES > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Short Circuit, Over Voltage Protections CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90~305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90~305VAC, 47~63Hz POWER FACTOR (Typ.) 0.92/230VAC (70%~100% full load) INPUT CURRENT (Typ.) 0.9A/230VAC POWER FACTOR (Typ.) 0.92/230VAC (70%~100% full load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.9A/230VAC COLD START, 60A/230VAC INRUSH CURRENT (Typ.) COLD START, 60A/230VAC LINE REGULATION ±5% LINE REGULATION ±5% LOAD REGULATION ±5% LOAD REGULATION ±5% SETUP, RISE TIME ≤1S at full load (cold start, power on) SETUP, RISE TIME ≤1S at full load (cold start, power on) RIPPLE <1V RIPPLE <4V SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 110-130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing OPERATING Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC MECHANICAL SPECIFICATION 22 20~60W Isolated LED Driver for Commercial LED Lighting MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 300g Weight: 305g 23 LN SERIES 8~40W LED Driver with Built-in Active PFC MODEL NUMBER STRUCTURE LN U 12 - C 350 Output Parameter CC type: Output Current(mA) CV type: Output Voltage(Vdc) * Not yet available in this series Output Type C = Constant current type V = Constant voltage type * Not yet available in this series Maximum Output Power (W) Input Voltage Range U = Universal(90~305VAC) Series Name FEATURES 3 Year Warranty High Efficiency up to 91% Active Power Factor Correction Universal Input Range: 90~305VAC Short Circuit and Over Voltage Protections Isolation Voltage: 3.85KVAC APPLICATIONS Indoor Lighting Spot Lighting Recessed Lighting Cabinet Lighting Down Lighting Certified to TUV, CE Safety Standards: UL8750, EN61347-1, EN61347-2-13 EMC Standards: EN55015, FCC Part15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 24 SAFETY APPROVAL SERIES OVERVIEW SERIES VIN OUTPUT (CC) CASE LNU8-C 90~305VAC 240, 350mA 80 x 31.8 x 24.2 mm LNU12-C 90~305VAC 240, 350, 530, 700mA 88.8 x 44.8 x 30.5 mm LNU18-C 90~305VAC 350, 530, 700mA 109.8 x 44.8 x 30.5 mm LNU25-C 90~305VAC 350, 530, 700, 1050mA 109.8 x 44.8 x 30.5 mm LNU40-C 90~305VAC 350, 530, 700, 1050, 1400mA 134.8 x 44.8 x 30.5 mm 25 LN SERIES LN SERIES 8W SPECIFICATIONS 8~40W LED Driver with Built-in Active PFC FEATURES FEATURES > 3 Year Warranty > Certified to TUV, CE > Active Power Factor Correction > Universal Input Range: 90~305VAC > Short Circuit and Over Voltage Protections > 3 Year Warranty > Certified to TUV, CE > Active Power Factor Correction > Universal Input Range: 90~305VAC > High Efficiency up to 85% > Short Circuit and Over Voltage Protections Constant Current Constant Current MODELS Model Output TOL. VNO-LOAD EFF. Model Output TOL. VNO-LOAD EFF. LNU8-C240 240mA (18~34V) ±5% 40V 80% LNU12-C240 240mA (25~50V) ±5% 60V 85% LNU8-C350 350mA (14~23V) ±5% 28V 79% LNU12-C350 350mA (18~36V) ±5% 45V 84% LNU12-C530 530mA (12~24V) ±5% 32V 83% LNU12-C700 700mA (9~18V) ±5% 25V 83% CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY Model CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.85/220VAC(70%~100% full load) INPUT CURRENT (Typ.) 0.06A/230VAC(full load) POWER FACTOR (Typ.) 0.9/220VAC(70%~100% full load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.1A/230VAC(full load) COLD START, 35A/230VAC INRUSH CURRENT (Typ.) COLD START, 35A/230VAC LINE REGULATION ±3% LINE REGULATION ±3% LOAD REGULATION ±3% LOAD REGULATION ±3% SETUP, RISE TIME ≤2S(cold start, power on) SETUP, RISE TIME ≤2S (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 120% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 120% Vout, recovers automatically after fault condition is removed OPERATING Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 INPUT OUTPUT EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. MIL-HDBK-217F (25°C) SAFETY EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. MIL-HDBK-217F (25°C) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~277VAC MECHANICAL SPECIFICATION AC INPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~277VAC 26 SPECIFICATIONS LN SERIES LN SERIES MODELS 12W 8~40W LED Driver with Built-in Active PFC MECHANICAL SPECIFICATION DC OUTPUT Dimensions in mm Dimensions in mm Weight: 45g Weight: 80g AC INPUT DC OUTPUT 27 LN SERIES LN SERIES 18/25W SPECIFICATIONS 8~40W LED Driver with Built-in Active PFC FEATURES FEATURES > 3 Year Warranty > Certified to TUV, CE > Active Power Factor Correction > Universal Input Range: 90~305VAC > High Efficiency up to 88% > Short Circuit and Over Voltage Protections > 3 Year Warranty > Certified to TUV, CE > Active Power Factor Correction > Universal Input Range: 90~305VAC > High Efficiency up to 91% > Short Circuit and Over Voltage Protections Constant Current Constant Current SPECIFICATIONS MODELS Model Output TOL. VNO-LOAD EFF. Model Output TOL. VNO-LOAD EFF. Model Output TOL. VNO-LOAD EFF. LNU18-C350 350mA (26~52V) ±5% 60V 88% LNU25-C350 350mA (36~72V) ±5% 90V 89% LNU40-C350 350mA (57~114V) ±5% 135V 91% LNU18-C530 530mA (17~34V) ±5% 45V 87% LNU25-C530 530mA (24~48V) ±5% 58V 88% LNU40-C530 530mA (38~76V) ±5% 90V 91% LNU18-C700 700mA (13~26V) ±5% 32V 87% LNU25-C700 700mA (18~36V) ±5% 45V 88% LNU40-C700 700mA (28~57V) ±5% 70V 90% LNU25-C1050 1050mA (12~24V) ±5% 32V 87% LNU40-C1050 1050mA (19~38V) ±5% 48V 90% LNU40-C1400 1400mA (14~29V) ±5% 40V 89% CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY LN SERIES LN SERIES MODELS CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.9/220VAC(70%~100% full load) INPUT CURRENT (Typ.) 18W: 0.15A/230VAC; 25W: 0.2A/230VAC(full load) POWER FACTOR (Typ.) 0.95/220VAC(70%~100% full load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.25A/230VAC(full load) COLD START, 35A/230VAC INRUSH CURRENT (Typ.) COLD START, 35A/230VAC LINE REGULATION ±3% LINE REGULATION ±5% LOAD REGULATION ±3% LOAD REGULATION ±5% SETUP, RISE TIME ≤2S (cold start, power on) SETUP, RISE TIME ≤2S (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 120% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 120% Vout, recovers automatically after fault condition is removed OPERATING Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -25°C ~ +50°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 INPUT OUTPUT EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. MIL-HDBK-217F (25°C) SAFETY EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. MIL-HDBK-217F (25°C) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~277VAC MECHANICAL SPECIFICATION AC INPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~277VAC 28 40W 8~40W LED Driver with Built-in Active PFC MECHANICAL SPECIFICATION DC OUTPUT Dimensions in mm Dimensions in mm Weight: 110g Weight: 153g AC INPUT DC OUTPUT 29 LS SERIES 12~35W IP30 Rated LED Power Supplies MODEL NUMBER STRUCTURE LS U 12 - C 350 Output Parameter CC type: Output Current(mA) CV type: Output Voltage(Vdc) Output Type C = Constant current type V = Constant voltage type Maximum Output Power (W) Input Voltage Range U = Universal (90~264VAC) Series Name FEATURES 2 Year Warranty Constant Current and Constant Voltage Output IP30 Rated for Indoor Lighting Class II, no FG 100% Burn-in Test Certified to CE APPLICATIONS Indoor Lighting Spot Lighting Recessed Lighting Cabinet Lighting Down Lighting Safety Standards: Design Refer to UL8750, EN61347-1, EN61347-2-13 EMC Standards: Compliance to EN55015, FCC Part15 Class B, EN 61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 30 SAFETY APPROVAL SERIES OVERVIEW SERIES VIN OUTPUT (CC or CV) CASE LS_12-C/V 90~264VAC 350, 700mA 5, 12, 15, 24Vdc 77 x 40 x 30 mm LS_16-C/V 90~264VAC 350, 700mA 5, 12, 15, 24Vdc 77 x 40 x 30 mm LS_25-C/V 90~264VAC 350, 500, 700, 1050mA 5, 12, 15, 24, 36Vdc 84 x 57 x 29.5 mm LS_35-C/V 90~264VAC 350, 500, 700, 1050mA 5, 12, 15, 24, 36Vdc 84 x 57 x 29.5 mm 31 LS SERIES SPECIFICATIONS 12~35W IP30 Rated LED Power Supplies FEATURES > 2 Year Warranty > IP30 Rated for Indoor Lighting > Class II, No FG > 100% Burn-in Test > Cooling by Free Air Convection > Short Circuit Protection > 2 Year Warranty > IP30 Rated for Indoor Lighting > Class II, No FG > 100% Burn-in Test > Cooling by Free Air Convection > Short Circuit Protection Constant Voltage MODELS SPECIFICATIONS Constant Current MODELS Constant Voltage MODELS MODELS Model Output TOL. RIPPLE EFF. Model Output TOL. RIPPLE EFF. Model Output TOL. RIPPLE EFF. Model Output TOL. RIPPLE EFF. LSU12-C350 350mA (22~36V) ±5% 300mAp-p 78% LSU12-V5 5V (0~2A) ±5% 100mVp-p 75% LSU16-C350 350mA (29~48V) ±5% 300mAp-p 78% LSU16-V5 5V (0~2.6A) ±5% 100mVp-p 75% LSU12-C700 700mA (11~18V) ±5% 250mAp-p 80% LSU12-V12 12V (0~1A) ±5% 120mVp-p 79% LSU16-C700 700mA (15~24V) ±5% 250mAp-p 81% LSU16-V12 12V (0~1.25A) ±5% 120mVp-p 80% LSU12-V15 15V (0~0.8A) ±5% 120mVp-p 78% LSU16-V15 15V (0~1A) ±5% 120mVp-p 80% LSU12-V24 24V (0~0.5A) ±5% 150mVp-p 81% LSU16-V24 24V (0~0.67A) ±5% 150mVp-p 82% INPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC/120-370VDC, 47~63Hz INPUT CURRENT (Typ.) 0.35A/115VAC, 0.2A/230VAC(full load) INRUSH CURRENT (Typ.) COLD START, 70A/230VAC LINE REGULATION ±1% LOAD REGULATION ±3% SETUP, RISE TIME (Typ.) LS SERIES CHARACTERISTICS OUTPUT VOLTAGE RANGE, FREQUENCY 90-264VAC/120-370VDC, 47~63Hz INPUT CURRENT (Typ.) 0.5A/115VAC, 0.3A/230VAC(full load) INRUSH CURRENT (Typ.) COLD START, 45A/230VAC(CC); 50A/230VAC(CV) LINE REGULATION ±1% LOAD REGULATION ±3% 3000ms, 180ms/230VAC(CC); 1500ms, 30ms/230VAC(CV) at full load SETUP, RISE TIME (Typ.) 3000ms, 200ms/230VAC(CC); 1500ms, 30ms/230VAC(CV) at full load SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OPERATING Temperature -25°C~+70°C(derating required), Humidity 20 ~ 90% RH non-condensing OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH TEMPERATURE COEFFICIENT ±0.2%/°C (0-50°C) TEMPERATURE COEFFICIENT ±0.2%/°C (0-50°C) SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. MIL-HDBK-217F (25°C) MTBF 400K hours min. MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=115VAC/230VAC * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=115VAC/230VAC MECHANICAL SPECIFICATION MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 105g Weight: 105g 77 77 DC OUT RED BLACK 150±10 BLUE BROWN 18 AWG RED BLACK 150±10 AC IN BLUE BROWN 18 AWG AC IN 77 18 AWG 29 29 77 18 AWG 150±10 18 AWG 40 150±10 18 AWG 40 DC OUT 32 16W 12~35W IP30 Rated LED Power Supplies FEATURES Constant Current LS SERIES LS SERIES 12W 18 AWG 18 AWG 33 LS SERIES SPECIFICATIONS 12~35W IP30 Rated LED Power Supplies FEATURES > 2 Year Warranty > IP30 Rated for Indoor Lighting > Class II, No FG > 100% Burn-in Test > Cooling by Free Air Convection > 2 Year Warranty > IP30 Rated for Indoor Lighting > Class II, No FG > 100% Burn-in Test > Cooling by Free Air Convection Constant Voltage MODELS 35W SPECIFICATIONS 12~35W IP30 Rated LED Power Supplies FEATURES Constant Current Constant Current MODELS Constant Voltage MODELS EFF. MODELS Model Output TOL. RIPPLE EFF. Model Output TOL. RIPPLE Model Output TOL. RIPPLE EFF. Model Output TOL. RIPPLE EFF. LSU25-C350 350mA (42~70V) ±5% 300mAp-p 83% LSU25-V5 5V (0~3.5A) ±5% 120mVp-p 75% LSU35-C350 350mA (60~100V) ±5% 350mAp-p 87% LSU35-V5 5V (0~5A) ±5% 120mVp-p 75% LSU25-C500 500mA (30~50V) ±5% 300mAp-p 85% LSU25-V12 12V (0~2.1A) ±5% 150mVp-p 82% LSU35-C500 500mA (42~70V) ±5% 350mAp-p 86% LSU35-V12 12V (0~3A) ±5% 150mVp-p 82% LSU25-C700 700mA (22~36V) ±5% 300mAp-p 86% LSU25-V15 15V (0~1.68A) ±5% 120mVp-p 78% LSU35-C700 700mA (30~50V) ±5% 350mAp-p 86% LSU35-V15 15V (0~1.68A) ±5% 150mVp-p 78% LSU25-C1050 1050mA (15~24V) ±5% 300mAp-p 86% LSU25-V24 24V (0~1.05A) ±5% 150mVp-p 84% LSU35-C1050 1050mA (20~33V) ±5% 350mAp-p 85% LSU35-V24 24V (0~1.5A) ±5% 180mVp-p 84% LSU25-V36 36V (0~0.7A) ±5% 150mVp-p 86% LSU35-V36 36V (0~1A) ±5% 180mVp-p 86% INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC/120-370VDC, 47~63Hz INPUT CURRENT (Typ.) 0.8A/115VAC, 0.4A/230VAC(full load) INRUSH CURRENT (Typ.) COLD START, 45A/230VAC LINE REGULATION ±1% LOAD REGULATION ±3% SETUP, RISE TIME (Typ.) VOLTAGE RANGE, FREQUENCY 90-264VAC/120-370VDC, 47~63Hz INPUT CURRENT (Typ.) 0.75A/115VAC, 0.5A/230VAC(full load) INRUSH CURRENT (Typ.) COLD START, 45A/230VAC LINE REGULATION ±1% LOAD REGULATION ±3% 1500ms, 30ms/230VAC at full load SETUP, RISE TIME (Typ.) 1500ms, 40ms/230VAC at full load SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH TEMPERATURE COEFFICIENT ±0.2%/°C (0-50°C) TEMPERATURE COEFFICIENT ±0.2%/°C (0-50°C) SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. MIL-HDBK-217F (25°C) MTBF 400K hours min. MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=115VAC/230VAC * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=115VAC/230VAC MECHANICAL SPECIFICATION MECHANICAL SPECIFICATION 3 Dimensions in mm Dimensions in mm Weight: 150g Weight: 150g 3 15.3 84 150±10 18 AWG DC OUT RED BLACK 84 7.3 AC IN 18 AWG 3 AC IN 3 84 18 AWG 30 30 84 18 AWG BLUE BROWN 15,3 150±10 15,3 18 AWG RED BLACK 57 7.3 150±10 BLUE BROWN 150±10 18 AWG DC OUT 7,3 57 7,3 34 LS SERIES CHARACTERISTICS 15.3 LS SERIES LS SERIES 25W 18 AWG 18 AWG 35 LC SERIES 20~40W IP67 Rated LED Power Supplies MODEL NUMBER STRUCTURE LC U 20 - C 350 D Dimming Option Blank = Without dimming D = With 0~10V dimming P = With PWM dimming Output Parameter CC type: Output Current(mA) CV type: Output Voltage(Vdc) * Not yet available in this series Output Type C = Constant current type V = Constant voltage type * Not yet available in this series Maximum Output Power (W) Input Voltage Range U = Universal(90~305VAC) Series Name FEATURES 5 Year Warranty Constant Current Output Active Power Factor Correction Universal AC Input Range: 90~305VAC Short Circuit, Over Voltage, Over Load, Over Temperature Protections Designed to Worldwide Safety Standards for Lighting APPLICATIONS Outdoor Lighting String Lights Wall Wash Lights Spot Lighting High/Low Bay Lighting Optional Dimming (0~10V, PWM) Certified to UL, CE SERIES OVERVIEW SERIES VIN OUTPUT (CC) CASE LC_20-C 90~305VAC 350, 450, 700, 1050mA 113 x 41.5 x 30 mm LC_30-C 90~305VAC 350, 450, 700, 1050mA 113 x 41.5 x 30 mm LC_40-C 90~305VAC 350, 450, 700, 1050, 1280, 1400, 1660mA 95 x 70 x 32 mm Safety Standards: UL8750, EN61347-1, EN61347-2-13 EMC Standards: EN55015, FCC Part15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 36 SAFETY APPROVAL 37 LC SERIES LC SERIES 20/30W SPECIFICATIONS 20~40W IP67 Rated LED Power Supplies FEATURES FEATURES > 5 Year Warranty > Universal AC Input Range: 90-305VAC > High PF up to 0.99 > Short Circuit and Over Voltage Protections > Cooling by Free Air Convection > Optional Dimming (0~10V, PWM) > 5 Year Warranty > Universal AC Input Range: 90-305VAC > High PF up to 0.99 > Short Circuit and Over Voltage Protections > Cooling by Free Air Convection > Optional Dimming (0~10V, PWM) Constant Current MODELS MODELS Model ① Output TOL. VNO-LOAD EFF. Model ① Output TOL. VNO-LOAD EFF. Model ① Output TOL. VNO-LOAD EFF. Model ① Output TOL. VNO-LOAD EFF. LCU20-C350 350mA (34~57V) ±5% 63V 88% LCU30-C350 350mA (52~86V) ±5% 95V 88% LCU40-C350 350mA (69~114V) ±5% 123V 91% LCU40-C1280 1280mA (19~31V) ±5% 34V 88% LCU20-C450 450mA (27~45V) ±5% 50V 87% LCU30-C450 450mA (40~67V) ±5% 74V 87% LCU40-C450 450mA (53~89V) ±5% 98V 91% LCU40-C1400 1400mA (17~29V) ±5% 32V 88% LCU20-C700 700mA (18~29V) ±5% 32V 86% LCU30-C700 700mA (26~43V) ±5% 48V 86% LCU40-C700 700mA (34~57V) ±5% 63V 90% LCU40-C1660 1660mA (14~24V) ±5% 27V 87% LCU20-C1050 1050mA (12~19V) ±5% 21V 85% LCU30-C1050 1050mA (17~29V) ±5% 32V 84% LCU40-C1050 1050mA (23~38V) ±5% 42V 89% INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 20W: 0.98/110VAC, 0.95/220VAC; 30W: 0.99/110VAC, 0.95/220VAC(70%~100% load) INPUT CURRENT (Typ.) 0.33A/110VAC, 0.16A/220VAC (full load) POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.43A/110VAC, 0.21A/220VAC (full load) COLD START, 24A/230VAC (full load) INRUSH CURRENT (Typ.) COLD START, 35A/230VAC (full load) LINE REGULATION 5% LINE REGULATION 1% LOAD REGULATION 5% LOAD REGULATION 3% SETUP, RISE TIME ≤2S/230VAC (cold start, power on) SETUP, RISE TIME ≤2S/230VAC (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL1310 Class2, UL1012 UL935 CAN/CSA-22.2 No.0, CSA-C22.2 No.107.1, CSA-C22.2 No.250.0, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL1310 Class2, UL1012 UL935 CAN/CSA-22.2 No.0, CSA-C22.2 No.107.1, CSA-C22.2 No.250.0, EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF, LIFE TIME 450K hours min. MIL-HDBK-217F (25°C), 80K hours min. MIL-HDBK-217F (25°C) INPUT OUTPUT ① Add suffix for dimming option, "D" (0~10V), "P" (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC PROTECTION ENVIRONMENT SAFETY LC SERIES LC SERIES SPECIFICATIONS Constant Current (30W) CHARACTERISTICS EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF, LIFE TIME 450K hours min. MIL-HDBK-217F (25°C), 80K hours min. MIL-HDBK-217F (25°C) ① Add suffix for dimming option, "D" (0~10V), "P" (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC MECHANICAL SPECIFICATION 38 40W 20~40W IP67 Rated LED Power Supplies MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 220g Weight: 330g 39 LE SERIES 20~100W IP67 Rated LED Power Supplies MODEL NUMBER STRUCTURE LE U 20 - C 350 Output Parameter CC type: Output Current(mA) CV type: Output Voltage(Vdc) Output Type C = Constant current type V = Constant voltage type Maximum Output Power (W) Input Voltage Range U = Universal (90~264VAC) Series Name FEATURES 3 Year Warranty IP67 Rated for Outdoor Lighting Operating Temperature Range: -25°C ~ +70°C Universal Input Range: 90~264VAC High Efficiency up to 87% Short Circuit and Over Voltage Protections APPLICATIONS Outdoor Lighting String Lights Wall Wash Lights Spot Lighting SERIES VIN OUTPUT (CC or CV) CASE High/Low Bay Lighting LEU20-C/V 90~264VAC 350, 700mA 5, 12, 15, 24, 36Vdc 140 x 30 x 22 mm LEU35-C/V 90~264VAC 700, 1050, 1400mA 5, 12, 15, 24, 36, 48Vdc 148 x 40 x 30 mm LEU60-C/V 90~264VAC 1050, 1400, 1750mA 5, 12, 15, 24, 36, 48Vdc 162.5 x 42.5 x 32 mm LEU100-V 90~264VAC 5, 12, 15, 24, 36, 48Vdc 190 x 52 x 37 mm Safety Standards: Design refer to UL879, UL1310, EN60950-1 EMC Standards: EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3 40 SERIES OVERVIEW SAFETY APPROVAL 41 LE SERIES LE SERIES 20W SPECIFICATIONS 20~100W IP67 Rated LED Power Supplies FEATURES > 3 Year Warranty > Application for LED Lighting and Electronic Screen Constant Current > Universal AC Input Range > Short Circuit and Over Voltage Protections > Cooling by Free Air Convection > Class II, No FG Constant Voltage MODELS Model Output TOL. RIPPLE 350mA (29-48V) ±5% 200mVp-p 83% EFF. LEU20-C700 700mA (18-30V) ±5% 200mVp-p 83% SAFETY 42 MODELS Model Output TOL. RIPPLE EFF. Model Output TOL. RIPPLE EFF(typ.) Model Output TOL. RIPPLE EFF. LEU20-V5 5V (3A Max.) ±5% 80mVp-p 77% LEU35-C700 700mA (29-48V) ±5% 200mVp-p 85% LEU35-V5 5V (6A Max.) ±6% 80mVp-p 78% LEU20-V12 12V (1.67A Max.) ±5% 120mVp-p 81% LEU35-C1050 1050mA (18-30V) ±5% 200mVp-p 85% LEU35-V12 12V (3A Max.) ±5% 120mVp-p 84% LEU20-V15 15V (1.33A Max.) ±5% 120mVp-p 83% LEU35-C1400 1400mA (15-24V) ±5% 200mVp-p 85% LEU35-V15 15V (2.4A Max.) ±5% 150mVp-p 84% LEU20-V24 24V (0.84A Max.) ±5% 120mVp-p 83% LEU35-V24 24V (1.5A Max.) ±5% 150mVp-p 85% LEU35-V36 36V (1A Max.) ±5% 150mVp-p 85% CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz INPUT CURRENT 0.55A MAX./115VAC, 0.35A MAX./230VAC (full load) INRUSH CURRENT (Typ.) COLD START, 70A/230VAC LINE REGULATION ±1% LOAD REGULATION ±2% SETUP, RISE TIME ≤500ms, 250ms (CC); 500ms, 25ms/230vac (CV) (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150%; Shut off output voltage, Diode clamp type OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH TEMPERATURE COEFFICIENT INPUT OUTPUT VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz INPUT CURRENT 1.1A MAX./115VAC, 0.7A MAX./230VAC (full load) INRUSH CURRENT (Typ.) COLD START, 55A/230VAC LINE REGULATION ±1% LOAD REGULATION ±2% (±5%/5V) SETUP, RISE TIME ≤500ms, 120ms/230VAC (CC); 500ms, 20ms (CV), (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150%; Shut off output voltage, Diode clamp type OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH ±0.03%/°C (0-50°C) TEMPERATURE COEFFICIENT ±0.03%/°C (0-50°C) SAFETY STANDARDS Design refer to UL879, UL1310, EN60950-1 SAFETY STANDARDS Design refer to UL1301, EN60950-1 EMC Compliance to EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3 EMC Compliance to EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3 MTBF 500K hours min. MIL-HDBK-217F (25°C) MTBF 700K hours min. MIL-HDBK-217F (25°C) PROTECTION ENVIRONMENT SAFETY 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes MECHANICAL SPECIFICATION MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 220g Weight: 340g LE SERIES LE SERIES ENVIRONMENT Constant Voltage MODELS CHARACTERISTICS PROTECTION > 3 Year Warranty > Application for LED Lighting and Electronic Screen Constant Current MODELS LEU20-C350 OUTPUT SPECIFICATIONS FEATURES > Universal AC Input Range > Short Circuit and Over Voltage Protections > Cooling by Free Air Convection > Class II, No FG INPUT 35W 20~100W IP67 Rated LED Power Supplies 43 LE SERIES LE SERIES 60W SPECIFICATIONS 20~100W IP67 Rated LED Power Supplies FEATURES > 3 Year Warranty > Application for LED Lighting and Electronic Screen > Universal AC Input Range > Short Circuit and Over Voltage Protections > Cooling by Free Air Convection > Class II, No FG > 3 Year Warranty > Application for LED Lighting and Electronic Screen Constant Voltage MODELS Constant Current MODELS Model EFF. Constant Voltage Output TOL. RIPPLE EFF. 76% Constant Voltage MODELS MODELS Model Output TOL. RIPPLE LEU60-V5 5V (8A Max.) ±8% 80mVp-p Model Output TOL. RIPPLE EFF. Model Output TOL. RIPPLE LEU60-C1050 1050mA (29-48V) ±5% 200mVp-p 86% LEU60-V12 12V (5A Max.) ±5% 120mVp-p 83% LEU100-V5 5V (12A Max.) ±5% 80mVp-p 80% LEU100-V24 24V (4.2A Max.) ±5% 150mVp-p 87% EFF. LEU60-C1400 1400mA (26-42V) ±5% 200mVp-p 85% LEU60-V15 15V (4A Max.) ±5% 120mVp-p 83% LEU100-V12 12V (8.5A Max.) ±5% 120mVp-p 85% LEU100-V36 36V (2.8A Max.) ±5% 150mVp-p 87% LEU60-C1750 1750mA (21-34V) ±5% 200mVp-p 86% LEU60-V24 24V (2.5A Max.) ±5% 150mVp-p 85% LEU100-V15 15V (6.7A Max.) ±5% 120mVp-p 87% LEU100-V48 48V (2.1A Max.) ±5% 150mVp-p 88% LEU60-V36 36V (1.67A Max.) ±5% 150mVp-p 85% LEU60-V48 48V (1.25A Max.) ±5% 150mVp-p 85% CHARACTERISTICS OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz INPUT CURRENT 1.2A MAX./115VAC, 1A MAX./230VAC (full load) INRUSH CURRENT (Typ.) COLD START, 60A/230VAC LINE REGULATION ±1% LOAD REGULATION ±2% (±6%/5V) SETUP, RISE TIME ≤500ms, 120ms/230VAC (CC); 500ms, 200ms (CV) (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150%; Shut off output voltage, Diode clamp type OPERATING INPUT OUTPUT VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz INPUT CURRENT 2.2A MAX./115VAC, 1.2A MAX./230VAC (full load) INRUSH CURRENT (Typ.) COLD START, 75A/230VAC LINE REGULATION ±1% LOAD REGULATION ±2% SETUP, RISE TIME 2000ms, 25ms/115VAC at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER CURRENT 110-150%; Hiccup mode, recovers automatically after fault condition is removed Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing OVER VOLTAGE 110-150%; recovers automatically after fault condition is removed STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 20 ~ 90% RH non-condensing TEMPERATURE COEFFICIENT ±0.03%/°C (0-50°C) STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 95% RH SAFETY STANDARDS Design refer to UL879, UL1310, EN60950-1 TEMPERATURE COEFFICIENT ±0.03%/°C (0-45°C) EMC Compliance to EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3 SAFETY STANDARDS Design refer to UL879, UL1310, EN60950-1 MTBF 700K hours min. MIL-HDBK-217F (25°C) EMC Compliance to EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3 MTBF 600K hours min. MIL-HDBK-217F (25°C) PROTECTION ENVIRONMENT SAFETY 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes MECHANICAL SPECIFICATION Dimensions in mm Weight: 400g LE SERIES INPUT LE SERIES SPECIFICATIONS FEATURES > Universal AC Input Range > Short Circuit and Over Voltage Protections > Cooling by Free Air Convection > Class II, No FG 44 100W 20~100W IP67 Rated LED Power Supplies 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes MECHANICAL SPECIFICATION Dimensions in mm Weight: 630g 45 LF SERIES 35~150W IP67 Rated Power Supplies with PFC MODEL NUMBER STRUCTURE LF U 20 - C 350 R L Warranty Year Blank: 3 Year Warranty L: 5 Year Warranty Ripple * Not available for 100W/150W models Blank: High Ripple R: Low Ripple * Not available for LFB models Output Parameter CC type: Output Current(mA) CV type: Output Voltage(Vdc) Output Type C = Constant current type V = Constant voltage type Maximum Output Power (W) Input Voltage Range U = Universal (90~264VAC) B = 230VAC(180~264VAC) * Only available for 35W/60W CV models FEATURES 3 or 5 Year Warranty Selectable Active Power Factor Correction IP67 Rated for Outdoor Lighting Operating Temperature Range: -25°C ~ +70°C Universal Input Range: 90~264VAC High Efficiency APPLICATIONS Outdoor Lighting String Lights Wall Wash Lights Spot Lighting High/Low Bay Lighting Short Circuit and Over Voltage Protections Safety Standards: Design refer to UL879, UL1310, TUV EN60950-1 EMC Standards: EN55022 Class B, EN61000-3-2 Class A, EN61000-3-3 46 Series Name SAFETY APPROVAL SERIES OVERVIEW SERIES VIN OUTPUT (CC or CV) CASE 90~264VAC 350, 500, 700, 1050mA 5, 12, 15, 24, 36Vdc 148 x 40 x 30 mm 90~264VAC 350, 700, 1050, 1400, 2100, 2800mA 5, 12, 15, 24, 36, 48Vdc 162.5 x 42.5 x 32 mm LFU100-C/V 90~264VAC 700, 1050, 1400, 1750, 2100mA 12, 15, 24, 36, 48Vdc 190 x 52 x 37 mm LFU150-C/V 90~264VAC 700, 1050, 1400, 1750, 2100, 2800, 3150mA 12, 15, 24, 36, 48Vdc 190 x 52 x 37 mm LFU35-C LF[ ]35-V LFU60-C LF[ ]60-V 47 LF SERIES LF SERIES 35W SPECIFICATIONS 35~150W IP67 Rated Power Supplies with PFC FEATURES > 3/5 Year Warranty > Application for LED Lighting and Electronic Screen > Active Power Factor Correction > Universal AC Input Range > Cooling by Free Air Convection > Active Power Factor Correction > Class II, No FG Constant Voltage MODELS Model ① Output TOL. RIPPLE② EFF(typ.) Output TOL. VNO-LOAD EFF(typ.) LFU35-V5 5V (6A Max.) ±5% 5%/50% 85% LFU35-C350 350mA (70-100V) ±5% 128V 85% LFU35-V12 12V (3A Max.) ±5% 5%/50% 85% LFU35-C500 500mA (49-70V) ±5% 80V 85% LFU35-V15 15V (2.4A Max.) ±5% 5%/50% 85% LFU35-C700 700mA (35-50V) ±5% 60V 85% LFU35-V24 24V (1.5A Max.) ±5% 5%/50% 85% LFU35-C1050 1050mA (23-33V) ±5% 40V 85% LFU35-V36 36V (1A Max.) ±5% 5%/50% 85% *[ ] = U or B, U (90~264VAC), B (180~264VAC) LF SERIES SAFETY MODELS Model ① Output TOL. RIPPLE ② EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) LFU60-V5 5V (8A Max.) ±5% 5%/50% 85% LFU60-C350 350mA (120-171V) ±5% 205V 85% LFU60-V12 12V (5A Max.) ±5% 5%/50% 85% LFU60-C700 700mA (60-86V) ±5% 103V 85% LFU60-V15 15V (4A Max.) ±5% 5%/50% 85% LFU60-C1050 1050mA (40-57V) ±5% 68V 85% LFU60-V24 24V (2.5A Max.) ±5% 5%/50% 85% LFU60-C1400 1400mA (30-43V) ±5% 51V 85% LFU60-V36 36V (1.67A Max.) ±5% 5%/50% 85% LFU60-C2100 2100mA (20-29V) ±5% 35V 85% LFU60-V48 48V (1.25A Max.) ±5% 5%/50% 85% LFU60-C2800 2800mA (14-21V) ±5% 25V 85% *[ ] = U or B, U (90~264VAC), B (180~264VAC) CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz POWER FACTOR (Typ.) 0.9/230VAC (70%~100% load) INPUT CURRENT (Typ.) 0.2A/230VAC (full load) POWER FACTOR (Typ.) 0.9/230VAC (70%~100% load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.36A/230VAC(full load) COLD START, 35A/230VAC INRUSH CURRENT (Typ.) COLD START, 35A/230VAC LINE REGULATION (Typ.) ±3% LINE REGULATION ±3% LOAD REGULATION (Typ.) ±3% LOAD REGULATION ±3% SETUP, RISE TIME (Typ.) 2S (CC); 1S (CV) (cold start, power on) SETUP, RISE TIME 2S (CC); 1S (CV) (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150%; Shut off output voltage, return to normal operation after the power is turn-on again OVER VOLTAGE 110-150%; Shut off output voltage, return to normal operation after the power is turn-on again OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH TEMPERATURE COEFFICIENT ±0.03%/°C (0-50°C) TEMPERATURE COEFFICIENT ±0.03%/°C (0-50°C) SAFETY STANDARDS Design refer to UL8750, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 MTBF 400K hours min. MIL-HDBK-217F (25°C) MTBF 400K hours min. MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY ① Above items are default to 3 year warranty, add suffix "L" for 5 year warranty ② Above items are default to high ripple, add suffix "R" for low ripple(except LFB35-V models) 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes ① Above items are default to 3 year warranty, add suffix "L" for 5 year warranty ② Above items are default to high ripple , add suffix "R" for low ripple(except LFB60-V models) 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes MECHANICAL SPECIFICATION MECHANICAL SPECIFICATION AC(N) BLUE AC(L) BROWEN Dimensions in mm Dimensions in mm Weight: 340g Weight: 400g LF SERIES CHARACTERISTICS ENVIRONMENT Constant Voltage MODELS Model ① PROTECTION > 3/5 Year Warranty > Short Circuit and Over Voltage Protections Constant Current MODELS Constant Current OUTPUT SPECIFICATIONS FEATURES > Universal AC Input Range > Short Circuit and Over Voltage Protections > Cooling by Free Air Convection > Class II, No FG INPUT 60W 35~100W IP67 Rated Power Supplies with PFC UL1015 18AWG T case UL1015 18AWG +V(RED) -V(BLACK) 48 49 LF SERIES LF SERIES 100W SPECIFICATIONS 35~150W IP67 Rated Power Supplies with PFC FEATURES 150W SPECIFICATIONS 35~150W IP67 Rated Power Supplies with PFC FEATURES > Universal AC Input Range > Short Circuit and Over Voltage Protections > Cooling by Free Air Convection > Active Power Factor Correction > 3/5 Year Warranty > Class II, No FG > 100% Burn-in Test > Universal AC Input Range > Cooling by Free Air Convection > Active Power Factor Correction > 100% Burn-in Test > 3/5 Year Warranty > Class II, No FG > Short Circuit and Over Voltage Protections Constant Current MODELS Constant Current Constant Voltage MODELS MODELS TOL. VNO-LOAD EFF(typ.) LFU150-C700 700mA (171-214) ±5% 256V 92% Model ① Output TOL. RIPPLE EFF(typ.) TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. RIPPLE EFF(typ.) LFU150-C1050 1050mA (114-142) ±5% 170V 92% LFU150-V12 12V(8A Max.) ±5% 5% 93% LFU100-C700 700mA (114-142) ±5% 170V 90% LFU100-V12 12V (7A Max.) ±5% 5% 87% LFU150-C1400 1400mA (86-107) ±5% 128V 92% LFU150-V15 15V(8A Max.) ±5% 5% 93% LFU100-C1050 1050mA (76-95) ±5% 114V 90% LFU100-V15 15V (6.7A Max.) ±5% 5% 87% LFU150-C1750 1750mA (68-86) ±5% 103V 92% LFU150-V24 24V(5A Max.) ±5% 5% 93% LFU100-C1400 1400mA (57-71) ±5% 85V 90% LFU100-V24 24V (4.2A Max.) ±5% 5% 87% LFU150-C2100 2100mA (57-71) ±5% 85V 92% LFU150-V36 36V(3.33A Max.) ±5% 5% 93% LFU100-C1750 1750mA (46-57) ±5% 68V 90% LFU100-V36 36V (2.8A Max.) ±5% 5% 87% LFU150-C2800 2800mA (43-54) ±5% 65V 92% LFU150-V48 48V(3.15A Max.) ±5% 5% 93% LFU100-C2100 2100mA (39-48) ±5% 58V 90% LFU100-V48 48V (2.1A Max.) ±5% 5% 87% LFU150-C3150 3150mA (39-48) ±5% 58V 92% INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-264VAC, 47~63Hz POWER FACTOR (Typ.) 0.9/230VAC (70%~100% load) INPUT CURRENT (Typ.) 0.6A/230VAC (full load) POWER FACTOR (Typ.) 0.94/230VAC (70%~100% load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.8A/230VAC (full load) COLD START, 35A/230VAC INRUSH CURRENT (Typ.) COLD START, 50A/230VAC LINE REGULATION ±1% LINE REGULATION ±1% LOAD REGULATION ±2% LOAD REGULATION ±2% SETUP, RISE TIME 1S (cold start, power on) SETUP, RISE TIME 2S (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150%; Shut off output voltage, return to normal operation after the power is turn-on again OVER VOLTAGE 110-150%; Shut off output voltage, return to normal operation after the power is turn-on again OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -25°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH TEMPERATURE COEFFICIENT ±0.03%/°C (0-50°C) TEMPERATURE COEFFICIENT ±0.03%/°C (0-50°C) SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 MTBF 200K hours min. MIL-HDBK-217F (25°C) MTBF 200K hours min. MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY ① Above items are default to 3 year warranty, add suffix "L" for 5 year warranty 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes ① Above items are default to 3 year warranty, add suffix "L" for 5 year warranty 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100~240VAC 2. Ripple & Noise are measured at 20MHz of bandwidth by using a 12'' twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor 3. Suitable for indoor or outdoor which away from direct sunlight conditions, avoid soaking in water for more than 30 minutes MECHANICAL SPECIFICATION MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 630g Weight: 630g LF SERIES ① CHARACTERISTICS LF SERIES MODELS Output Output Model 50 Constant Voltage Model ① 51 LG SERIES 30~85W LED Power Supplies for Outdoor Lighting MODEL NUMBER STRUCTURE LG U 75 - C 350 D Dimming Option Blank=Without dimming D = With 0~10V dimming P = With PWM dimming Output Parameter CC type: Output Current (mA) Output Type C = Constant current type Maximum Output Power (W) Input Voltage Range U = Universal (90~305VAC) FEATURES APPLICATIONS IP67 Rated for Outdoor Lighting Outdoor Lighting Universal Input Range: 90~305VAC Street Lighting High Efficiency up to 93% Active Power Factor Correction, 2 Level Operating Temperature Range: -35°C ~ +70°C Optional Dimming (0~10V, PWM) Spot Lighting Flood Lighting High/Low Bay Lights SERIES OVERVIEW SERIES VIN OUTPUT (CC) CASE LGU30-C 90~305VAC 350, 450, 700, 1050mA 193 x 43.5 x 34.5 mm 5 Year Warranty LGU40-C 90~305VAC 350, 450, 700, 1050, 1280, 1400, 1660mA 193 x 43.5 x 34.5 mm Safety Standards: Design refer to UL8750, UL935, UL1012, UL1310 CLASS 2, EN61347-1 , EN61347-2-13 LGU50-C 90~305VAC 350, 450, 700, 1050, 1400mA 193 x 43.5 x 34.5 mm LGU60-C 90~305VAC 350, 450, 700, 1050, 1400, 1750, 2100mA 177 x 65.5 x 39.5 mm LGU75-C 90~305VAC 350, 450, 700, 1050, 1400, 1750, 2100mA 177 x 65.5 x 39.5 mm LGU85-C 90~305VAC 350, 700, 1050, 1400, 1750, 2100, 2800mA 177 x 65.5 x 39.5 mm All-Round Protections: Short Circuit, Over Voltage, Over Temperature Landscape Lighting Certified to UL and CE EMC Standards: EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 52 Series Name SAFETY APPROVAL 53 LG SERIES 30~85W LED Power Supplies for Outdoor Lighting LG SERIES 30W SPECIFICATIONS FEATURES > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) > Universal Input: 90~305VAC > High Efficiency up to 88% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting Constant Current > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) Constant Current MODELS MODELS Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) LGU30-C350 350mA (60~86V) ±5% 111V 88% LGU40-C350 350mA (80~114V) ±5% 148V 88% LGU40-C1280 1280mA (22~31V) ±5% 40V 88% LGU30-C450 450mA (47~67V) ±5% 87V 88% LGU40-C450 450mA (63~89V) ±5% 115V 88% LGU40-C1400 1400mA (21~29V) ±5% 37V 88% LGU30-C700 700mA (30~43V) ±5% 55V 88% LGU40-C700 700mA (40~57V) ±5% 74V 88% LGU40-C1660 1660mA (17~24V) ±5% 31V 88% LGU30-C1050 1050mA (20~29V) ±5% 37V 88% LGU40-C1050 1050mA (27~38V) ±5% 49V 88% INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.95/220VAC(70%~100% full load) INPUT CURRENT 0.33A/110VAC, 0.16A/220VAC (full load) POWER FACTOR (Typ.) 0.99/110VAC, 0.96/230VAC (70%~100% full load) INPUT CURRENT INRUSH CURRENT 0.21A/220VAC (full load) COLD START, 24A/230VAC INRUSH CURRENT COLD START, 35A/230VAC LINE REGULATION 1% LINE REGULATION 1% LOAD REGULATION 3% LOAD REGULATION 3% SETUP, RISE TIME 2S at full load (cold start, power on) SETUP, RISE TIME 2S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C(derating required), Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC PROTECTION ENVIRONMENT SAFETY LG SERIES CHARACTERISTICS LG SERIES SPECIFICATIONS FEATURES > Universal Input: 90~305VAC > High Efficiency up to 88% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION 54 40W 30~85W LED Power Supplies for Outdoor Lighting MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 455g Weight: 455g 55 LG SERIES LG SERIES 50W SPECIFICATIONS 30~85W LED Power Supplies for Outdoor Lighting FEATURES > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) > Universal Input: 90~305VAC > High Efficiency up to 88% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting Constant Current > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) Constant Current MODELS MODELS Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) LGU50-C350 350mA (100~143V) ±5% 185V 88% LGU50-C1050 1050mA (34~48V) ±5% 62V 88% LGU60-C350 350mA (120~171V) ±5% 222V 85% LGU60-C1400 1400mA(31~43V) ±5% 55V 85% LGU50-C450 450mA (78~111V) ±5% 144V 88% LGU50-C1400 1400mA (26~36V) ±5% 46V 88% LGU60-C450 450mA (93~133V) ±5% 172V 85% LGU60-C1750 1750mA(24~34V) ±5% 44V 85% LGU50-C700 700mA (50~71V) ±5% 92V 88% LGU50-C2100 2100mA (17~24V) ±5% 31V 88% LGU60-C700 700mA (60~85V) ±5% 110V 85% LGU60-C2100 2100mA(20~28V) ±5% 36V 85% LGU60-C1050 1050mA (40~57V) ±5% 74V 85% INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/230VAC (70%~100% full load) INPUT CURRENT 0.26A/230VAC (full load) POWER FACTOR (Typ.) 0.99/110VAC, 0.95/230VAC (70%~100% full load) INPUT CURRENT INRUSH CURRENT 0.32A/230VAC (full load) COLD START, 35A/230VAC INRUSH CURRENT COLD START, 65A/230VAC LINE REGULATION 1% LINE REGULATION 1% LOAD REGULATION 3% LOAD REGULATION 3% SETUP, RISE TIME 2S at full load (cold start, power on) SETUP, RISE TIME 2S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF, LIFE TIME 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC SAFETY LG SERIES CHARACTERISTICS LG SERIES SPECIFICATIONS FEATURES > Universal Input: 90~305VAC > High Efficiency up to 88% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION 56 60W 30~85W LED Power Supplies for Outdoor Lighting MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 455g Weight: 745g 57 LG SERIES LG SERIES 75W SPECIFICATIONS 30~85W LED Power Supplies for Outdoor Lighting FEATURES > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) > Universal Input: 90~305VAC > High Efficiency up to 88% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting Constant Current > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) Constant Current MODELS MODELS Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model Output TOL. VNO-LOAD EFF(typ.) LGU75-C350 350mA (150~214V) ±5% 278V 88% LGU75-C1400 1400mA (38~54V) ±5% 70V 88% LGU85-C350 350mA (170-243V) ±5% 315V 88% LGU85-C1750 1750mA (35-49V) ±5% 63V 88% LGU75-C450 450mA (117~167V) ±5% 217V 88% LGU75-C1750 1750mA (30~43V) ±5% 55V 88% LGU85-C700 700mA (85-121V) ±5% 157V 88% LGU85-C2100 2100mA (28-40V) ±5% 52V 88% LGU75-C700 700mA (75~107V) ±5% 139V 88% LGU75-C2100 2100mA (26~36V) ±5% 46V 88% LGU85-C1050 1050mA (56-81V) ±5% 105V 88% LGU85-C2800 2800mA (21-30V) ±5% 39V 88% LGU75-C1050 1050mA (50~71V) ±5% 92V 88% LGU85-C1400 1400mA (43-61V) ±5% 79V 88% INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/230VAC (70%~100% full load) INPUT CURRENT 0.42A/230VAC (full load) POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT INRUSH CURRENT 0.9A/110VAC, 0.44A/220VAC (full load) COLD START, 35A/230VAC INRUSH CURRENT COLD START, 50A/230VAC LINE REGULATION 1% LINE REGULATION 1% LOAD REGULATION 3% LOAD REGULATION 3% SETUP, RISE TIME 2S at full load (cold start, power on) SETUP, RISE TIME 1S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, FCC Part 15 Class B, ANSI C63.4: 2009, EN61000-3-2, 3, EN61000, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC SAFETY LG SERIES CHARACTERISTICS LG SERIES SPECIFICATIONS FEATURES > Universal Input: 90~305VAC > High Efficiency up to 88% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION 58 85W 30~85W LED Power Supplies for Outdoor Lighting MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 745g Weight: 745g 59 LGS SERIES 100~250W LED Power Supplies for Outdoor Lighting MODEL NUMBER STRUCTURE LGS U 100 - C 350 D Dimming Option Blank=Without dimming D = With 0~10V dimming P = With PWM dimming Output Parameter CC type: Output Current (mA) Output Type C = Constant current type Maximum Output Power (W) Input Voltage Range U = Universal (90~305VAC) Series Name FEATURES APPLICATIONS Constant Current Output Outdoor Lighting High Efficiency Universal AC Input: 90-305VAC Active Power Factor Correction All-Round Protections: Short Circuit, Over Voltage, Over Temperature IP67 Rated for Outdoor Lighting Optional Dimming (0~10V, PWM) Street Lighting Spot Lighting Flood Lighting High/Low Bay Lights Landscape Lighting 5 Year Warranty Safety Standards: Design refer to UL8750, UL935, UL1012, UL1310 CLASS 2, EN61347-1 , EN61347-2-13 EMC Standards: EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 60 SAFETY APPROVAL SERIES OVERVIEW SERIES VIN OUTPUT (CC) CASE LGSU100-C 90~305VAC 350, 450, 700, 1050, 1400, 1750, 2100, 3150mA 228 x 65.5 x 39.5mm LGSU120-C 90~305VAC 450, 700, 1050, 1400, 1750, 2100, 2800, 3150, 4200mA 228 x 65.5 x 39.5mm LGSU150-C 90~305VAC 700, 1050, 1400, 1750, 2100, 2800, 3150, 4200mA 228 x 65.5 x 39.5mm LGSU185-C 90~305VAC 700, 1050, 1400, 1750, 2100, 2450, 2800, 3150, 3500, 4200mA 226 x 67.5 x 39.7 mm LGSU200-C 90~305VAC 700, 1050, 1400, 1750, 2100, 2450, 2800, 3150, 3500, 4200mA 226 x 67.5 x 39.7 mm LGSU250-C 90~305VAC 1400, 1750, 2100, 2450, 2800, 3150, 3500, 4200, 4800mA 242 x 67.5 x 39.7mm 61 LGS SERIES LGS SERIES 100W SPECIFICATIONS 100~250W LED Power Supplies for Outdoor Lighting FEATURES > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) > Universal Input: 90~305VAC > High Efficiency up to 90% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting Constant Current > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) Constant Current MODELS MODELS Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) LGSU100-C350 350mA (214-286V) ±5% 371V 90% LGSU100-C1400 1400mA (54-72V) ±5% 93V 90% LGSU120-C450 450mA (200-267V) ±5% 347V 90% LGSU120-C1750 1750mA (51-69V) ±5% 89V 90% LGSU100-C450 450mA (166-222V) ±5% 288V 90% LGSU100-C1750 1750mA (42-57V) ±5% 74V 90% LGSU120-C700 700mA (128-171V) ±5% 222V 90% LGSU120-C2100 2100mA (43-58V) ±5% 75V 90% LGSU100-C700 700mA (107-143V) ±5% 185V 90% LGSU100-C2100 2100mA (36-48V) ±5% 62V 90% LGSU120-C1050 1050mA (85-114V) ±5% 148V 90% LGSU120-C2800 2800mA (32-43V) ±5% 55V 90% LGSU100-C1050 1050mA (71-95V) ±5% 123V 90% LGSU100-C3150 3150mA (24-32V) ±5% 41V 90% LGSU120-C1400 1400mA (64-86V) ±5% 111V 90% LGSU120-C3150 3150mA (28-38V) ±5% 49V 90% LGSU120-C4200 4200mA (21-29V) ±5% 37V 90% CHARACTERISTICS OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT 1A/110VAC, 0.5A/220VAC (full load) POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT INRUSH CURRENT 1.25A/110VAC, 0.6A/220VAC (full load) COLD START, 65A/230VAC INRUSH CURRENT COLD START, 65A/230VAC LINE REGULATION 1% LINE REGULATION 1% LOAD REGULATION 3% LOAD REGULATION 3% SETUP, RISE TIME 1S at full load (cold start, power on) SETUP, RISE TIME 2S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT ENVIRONMENT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION PROTECTION SAFETY ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC Dimensions in mm Weight: 930g MECHANICAL SPECIFICATION Dimensions in mm Weight: 930g LGS SERIES INPUT LGS SERIES SPECIFICATIONS FEATURES > Universal Input: 90~305VAC > High Efficiency up to 90% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting 62 120W 100~250W LED Power Supplies for Outdoor Lighting 63 LGS SERIES LGS SERIES 150W SPECIFICATIONS 100~250W LED Power Supplies for Outdoor Lighting FEATURES > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) > Universal Input: 90~305VAC > High Efficiency up to 92% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting Constant Current > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) Constant Current MODELS MODELS Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) LGSU150-C700 700mA (160-214V) ±5% 278V 90% LGSU150-C2800 2800mA (40-54V) ±5% 70V 90% LGSU185-C700 700mA (211-264V) ±5% 343V 92% LGSU185-C2450 2450mA (60-76V) ±5% 98V 92% LGSU150-C1050 1050mA (107-143V) ±5% 185V 90% LGSU150-C3150 3150mA (36-48V) ±5% 62V 90% LGSU185-C1050 1050mA (140-176V) ±5% 228V 92% LGSU185-C2800 2800mA (52-66V) ±5% 85V 92% LGSU150-C1400 1400mA (80-107V) ±5% 139V 90% LGSU150-C3500 3500mA (32-43V) ±5% 55V 90% LGSU185-C1400 1400mA (105-132V) ±5% 171V 92% LGSU185-C3150 3150mA (47-59V) ±5% 76V 92% LGSU150-C2100 2100mA (53-71V) ±5% 92V 90% LGSU150-C4200 4200mA (27-36V) ±5% 46V 90% LGSU185-C1750 1750mA (84-106V) ±5% 137V 92% LGSU185-C3500 3500mA (42-53V) ±5% 68V 92% LGSU185-C2100 2100mA (70-88V) ±5% 114V 92% LGSU185-C4200 4200mA (35-44V) ±5% 57V 92% CHARACTERISTICS OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT 1.6A/110VAC, 0.75A/220VAC (full load) POWER FACTOR (Typ.) 0.98/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT INRUSH CURRENT 1.86A/110VAC, 0.93A/220VAC (full load) COLD START, 65A/230VAC INRUSH CURRENT COLD START, 65A/230VAC LINE REGULATION 1% LINE REGULATION 1% LOAD REGULATION 3% LOAD REGULATION 3% SETUP, RISE TIME 1S at full load (cold start, power on) SETUP, RISE TIME 1S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT ENVIRONMENT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM). * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION PROTECTION SAFETY ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC Dimensions in mm Weight: 930g MECHANICAL SPECIFICATION Dimensions in mm Weight: 930g LGS SERIES INPUT LGS SERIES SPECIFICATIONS FEATURES > Universal Input: 90~305VAC > High Efficiency up to 90% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting 64 185W 100~250W LED Power Supplies for Outdoor Lighting 65 LGS SERIES LGS SERIES 200W SPECIFICATIONS 100~250W LED Power Supplies for Outdoor Lighting FEATURES > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) > Universal Input: 90~305VAC > High Efficiency up to 92% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting Constant Current > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) Constant Current MODELS MODELS Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) LGSU200-C700 700mA (228-286V) ±5% 371V 92% LGSU200-C2450 2450mA (65-85V) ±5% 106V 92% LGSU250-C1400 1400mA (143-179V) ±5% 232V 92% LGSU250-C3150 3150mA (63-79V) ±5% 102V 92% LGSU200-C1050 1050mA (152-190V) ±5% 247V 92% LGSU200-C2800 2800mA (56-71V) ±5% 92V 92% LGSU250-C1750 1750mA (114-143V) ±5% 185V 92% LGSU250-C3500 3500mA (57-72V) ±5% 93V 92% LGSU200-C1400 1400mA (114-143V) ±5% 185V 92% LGSU200-C3150 3150mA (50-63V) ±5% 81V 92% LGSU250-C2100 2100mA (95-119V) ±5% 154V 92% LGSU250-C4200 4200mA (48-60V) ±5% 78V 92% LGSU200-C1750 1750mA (91-114V) ±5% 148V 92% LGSU200-C3500 3500mA (45-57V) ±5% 74V 92% LGSU250-C2450 2450mA (81-102V) ±5% 132V 92% LGSU250-C4800 4800mA (41-52V) ±5% 67V 92% LGSU200-C2100 2100mA (76-95V) ±5% 123V 92% LGSU200-C4200 4200mA (38-48V) ±5% 62V 92% LGSU250-C2800 2800mA (71-79V) ±5% 115V 92% CHARACTERISTICS OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT 2.1A/110VAC, 1A/220VAC (full load) POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT INRUSH CURRENT 1.4A/230VAC (full load) COLD START, 65A/230VAC INRUSH CURRENT COLD START, 65A/230VAC LINE REGULATION 1% LINE REGULATION 1% LOAD REGULATION 3% LOAD REGULATION 3% SETUP, RISE TIME 1S at full load (cold start, power on) SETUP, RISE TIME 1S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT ENVIRONMENT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION PROTECTION SAFETY ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC Dimensions in mm Weight: 930g MECHANICAL SPECIFICATION Dimensions in mm Weight: 930g LGS SERIES INPUT LGS SERIES SPECIFICATIONS FEATURES > Universal Input: 90~305VAC > High Efficiency up to 92% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting 66 250W 100~250W LED Power Supplies for Outdoor Lighting 67 LGC SERIES 100~150W LED Power Supplies for Outdoor Lighting MODEL NUMBER STRUCTURE LGC U 100 - C 350 D Dimming Option Blank=Without dimming D = With 0~10V dimming P = With PWM dimming Output Parameter CC type: Output Current (mA) Output Type C = Constant current type Maximum Output Power (W) Input Voltage Range U = Universal (90~305VAC) Series Name FEATURES APPLICATIONS Constant Current Output Outdoor Lighting High Efficiency Universal AC Input: 90-305VAC Active Power Factor Correction All-Round Protections: Short Circuit, Over Voltage, Over Temperature IP67 Rated for Outdoor Lighting Optional Dimming (0~10V, PWM) Street Lighting Spot Lighting Flood Lighting High/Low Bay Lights Landscape Lighting 5 Year Warranty Safety Standards: Design refer to UL8750, UL935, UL1012, UL1310 CLASS 2, EN61347-1 , EN61347-2-13 EMC Standards: EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 68 SAFETY APPROVAL SERIES OVERVIEW SERIES VIN OUTPUT (CC) CASE LGCU100-C 90~305VAC 350, 450, 700, 1050, 1400, 1750, 2100, 3150mA 228 x 65.5 x 39.5mm LGCU150-C 90~305VAC 700, 1050, 1400, 1750, 2100, 2800, 3150, 4200mA 228 x 65.5 x 39.5mm 69 LGC SERIES LGS SERIES 100W SPECIFICATIONS 100~150W LED Power Supplies for Outdoor Lighting FEATURES > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) > Universal Input: 90~305VAC > High Efficiency up to 89% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting Constant Current > All-round Protection: SCP, OVP, OTP > Optional Dimming (0~10V, PWM) Constant Current MODELS MODELS Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) Model ① Output TOL. VNO-LOAD EFF(typ.) LGCU100-C350 350mA (214-286V) ±5% 371V 89% LGCU100-C1400 1400mA (54-72V) ±5% 93V 89% LGCU150-C700 700mA (160-214V) ±5% 278V 89% LGCU150-C2800 2800mA (40-54V) ±5% 70V 89% LGCU100-C450 450mA (166-222V) ±5% 288V 89% LGCU100-C1750 1750mA (42-57V) ±5% 74V 89% LGCU150-C1050 1050mA (107-143V) ±5% 185V 89% LGCU150-C3150 3150mA (36-48V) ±5% 62V 89% LGCU100-C700 700mA (107-143V) ±5% 185V 89% LGCU100-C2100 2100mA (36-48V) ±5% 62V 89% LGCU150-C1400 1400mA (80-107V) ±5% 139V 89% LGCU150-C3500 3500mA (32-43V) ±5% 55V 89% LGCU100-C1050 1050mA (71-95V) ±5% 123V 89% LGCU100-C3150 3150mA (24-32V) ±5% 41V 89% LGCU150-C2100 2100mA (53-71V) ±5% 92V 89% LGCU150-C4200 4200mA (27-36V) ±5% 46V 89% CHARACTERISTICS OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT 1A/110VAC, 0.5A/220VAC (full load) INRUSH CURRENT VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (70%~100% full load) INPUT CURRENT 1.6A/110VAC, 0.75A/220VAC (full load) COLD START, 65A/230VAC INRUSH CURRENT COLD START, 65A/230VAC LINE REGULATION 1% LINE REGULATION 1% LOAD REGULATION 3% LOAD REGULATION 3% SETUP, RISE TIME 1S at full load (cold start, power on) SETUP, RISE TIME 1S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 200K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT ENVIRONMENT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION PROTECTION SAFETY ① Add suffix for dimming option, “D” (0~10V), “P” (PWM). * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC Dimensions in mm Weight: 930g MECHANICAL SPECIFICATION Dimensions in mm Weight: 930g LGC SERIES INPUT LGC SERIES SPECIFICATIONS FEATURES > Universal Input: 90~305VAC > High Efficiency up to 89% > High PF up to 0.99 > 5 Year Warranty > IP67 for Outdoor Lighting 70 150W 100~150W LED Power Supplies for Outdoor Lighting 71 LGE SERIES 80~250W LED Driver with Adjustable Output Current MODEL NUMBER STRUCTURE LGE U 80 - C V 24 D Dimming Option Blank=Without dimming D = With 0~10V dimming P = With PWM dimming Maximum Output Voltage Constant Voltage Mode Constant Current Mode Maximum Output Power (W) Input Voltage Range U = Universal (90~305VAC) FEATURES APPLICATIONS Constant Current and Constant Voltage Output Outdoor Lighting IP65 Rated for Outdoor Lighting Street Lighting Adjustable Output Current 60%~100% Spot Lighting Universal Input Range: 90~305VAC Active Power Factor Correction Operating Temperature Range: -35°C ~ +70°C Optional Dimming (0~10V, PWM) Flood Lighting High/Low Bay Lights Landscape Lighting All-Round Protections: Short Circuit, Over Voltage, Over Temperature 5 Year Warranty Safety Standards: Design refer to UL8750, UL935, UL1012, UL1310 CLASS 2, EN61347-1 , EN61347-2-13 EMC Standards: Compliance to EN55015, FCC Part 15 Class B, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 72 SAFETY APPROVAL Series Name SERIES OVERVIEW SERIES VIN OUTPUT (CC or CV) CASE LGEU80-C 90~305VAC 1500, 1700, 2200, 3400, 5000mA 177 x 68 x 38.8 mm LGEU100-C 90~305VAC 700, 1050, 1400, 2100, 2800, 4200, 8300mA 215 x 68 x 38.8 mm LGEU150-C 90~305VAC 700, 1050, 1400, 2100, 2800, 3150, 3500, 4200, 6250mA 215 x 68 x 38.8 mm LGEU200-C 90~305VAC 1400, 1750, 2100, 2400, 2800, 3150, 3500, 4200, 5500, 8300mA 226 x 68 x 38.8 mm LGEU250-C 90~305VAC 1400, 1750, 2100, 2450, 2800, 3150, 3500, 4200, 5000, 8300mA 244 x 68 x 38.8 mm 73 LGE SERIES 80~250W LED Driver with Adjustable Output Current LGE SERIES 80W SPECIFICATIONS FEATURES FEATURES > Universal Input: 90~305Vac > All-round Protection: SCP, > Adjustable Output Current 60%~100% OVP, OTP > High PF up to 0.99 > Optional Dimming (0~10V, > 5 Year Warranty PWM) > IP65 for Outdoor Lighting > Universal Input: 90~305Vac > All-round Protection: SCP, > Adjustable Output Current 60%~100% OVP, OTP > High PF up to 0.99 > Optional Dimming (0~10V, > 5 Year Warranty PWM) > IP65 for Outdoor Lighting Constant Current / Constant Voltage Constant Current / Constant Voltage MODELS Model ① Output-C Output-V VNO-LOAD EFF(typ.) Model ① Output-C Output-V VNO-LOAD EFF(typ.) Model ① Output-C Output-V VNO-LOAD EFF(typ.) LGEU80-CV54 1500mA 38-54V 70V 90% LGEU100-CV142 700mA 107-142V 184V 88% LGEU100-CV24 4200mA 18-24V 31V 88% LGEU80-CV48 1700mA 34-48V 62V 90% LGEU100-CV95 1050mA 71-95V 123V 88% LGEU100-CV12 8300mA 9-12V 15V 88% LGEU80-CV36 2200mA 25-36V 46V 90% LGEU100-CV71 1400mA 53-71V 92V 88% LGEU80-CV24 3400mA 17-24V 31V 90% LGEU100-CV48 2100mA 36-48V 62V 88% LGEU80-CV12 5500mA 8.4-12V 15V 90% LGEU100-CV36 2800mA 27-36V 46V 88% OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/230VAC (70%~100% full load) INPUT CURRENT 0.42A/230VAC POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (full load) INPUT CURRENT INRUSH CURRENT 1.2A/110VAC, 0.6A/220VAC COLD START, 35A/230VAC INRUSH CURRENT COLD START, 65A/230VAC OUTPUT CURRENT ADJUSTABLE 60%~100% OUTPUT CURRENT ADJUSTABLE 60%~100% OUTPUT VOLTAGE ADJUSTABLE ±10% OUTPUT VOLTAGE ADJUSTABLE ±10% LINE REGULATION ±1% LINE REGULATION ±1% LOAD REGULATION ±3% LOAD REGULATION ±3% SETUP, RISE TIME 2S at full load (cold start, power on) SETUP, RISE TIME 1S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 MTBF, LIFE TIME 400K hours typ. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 400K hours typ. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC SAFETY ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 870g Weight: 950g LGE SERIES INPUT LGE SERIES SPECIFICATIONS MODELS CHARACTERISTICS 74 100W 80~250W LED Driver with Adjustable Output Current 75 LGE SERIES LGE SERIES 150W SPECIFICATIONS 80~250W LED Driver with Adjustable Output Current FEATURES FEATURES > Universal Input: 90~305Vac > All-round Protection: SCP, > Adjustable Output Current 60%~100% OVP, OTP > High PF up to 0.99 > Optional Dimming (0~10V, > 5 Year Warranty PWM) > IP65 for Outdoor Lighting > Universal Input: 90~305Vac > All-round Protection: SCP, > Adjustable Output Current 60%~100% OVP, OTP > High PF up to 0.99 > Optional Dimming (0~10V, > 5 Year Warranty PWM) > IP65 for Outdoor Lighting Constant Current / Constant Voltage Constant Current / Constant Voltage MODELS Model ① Output-C Output-V VNO-LOAD EFF(typ.) Model ① Output-C Output-V VNO-LOAD EFF(typ.) Model ① Output-C Output-V VNO-LOAD EFF(typ.) Model ① Output-C Output-V VNO-LOAD EFF(typ.) LGEU150-CV214 700mA 160-214V 278V 88% LGEU150-CV48 3150mA 36-48V 62V 88% LGEU200-CV143 1400mA 114-143V 278V 90% LGEU200-CV63 3150mA 50-63V 81V 90% LGEU150-CV142 1050mA 107-143V 185V 88% LGEU150-CV42 3500mA 32-43V 55V 88% LGEU200-CV114 1750mA 91-114V 185V 90% LGEU200-CV57 3500mA 46-57V 74V 90% LGEU150-CV107 1400mA 80-107V 139V 88% LGEU150-CV36 4200mA 27-36V 46V 88% LGEU200-CV95 2100mA 76-95V 139V 90% LGEU200-CV48 4200mA 38-48V 62V 90% LGEU150-CV71 2100mA 53-71V 92V 88% LGEU150-CV24 6250mA 18-24V 31V 88% LGEU200-CV83 2400mA 67-83V 92V 90% LGEU200-CV36 5500mA 29-36V 46V 90% LGEU150-CV54 2800mA 40-54V 70V 88% LGEU200-CV71 2800mA 57-71V 70V 90% LGEU200-CV24 8300mA 18-24V 31V 90% OUTPUT PROTECTION ENVIRONMENT SAFETY CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/220VAC (full load) INPUT CURRENT 1.6A/110VAC, 0.75A/220VAC POWER FACTOR (Typ.) 0.99/110VAC, 0.96/230VAC(70~100% full load) INPUT CURRENT INRUSH CURRENT 1.2A/230VAC COLD START, 65A/230VAC INRUSH CURRENT COLD START, 65A/230VAC OUTPUT CURRENT ADJUSTABLE 60%~100% OUTPUT CURRENT ADJUSTABLE 60%~100% OUTPUT VOLTAGE ADJUSTABLE ±10% OUTPUT VOLTAGE ADJUSTABLE ±10% LINE REGULATION ±1% LINE REGULATION ±1% LOAD REGULATION ±3% LOAD REGULATION ±3% SETUP, RISE TIME 1S at full load (cold start, power on) SETUP, RISE TIME 2S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 MTBF, LIFE TIME 400K hours typ. refer to MIL-HDBK-217F (25°C) MTBF, LIFE TIME 400K hours typ. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC SAFETY ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC MECHANICAL SPECIFICATION MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 950g Weight: 1050g LGE SERIES INPUT LGE SERIES SPECIFICATIONS MODELS CHARACTERISTICS 76 200W 80~250W LED Driver with Adjustable Output Current 77 LGE SERIES 250W SPECIFICATIONS 80~250W LED Driver with Adjustable Output Current Frequently Asked Questions on LED Drivers FEATURES > Universal Input: 90~305Vac > All-round Protection: SCP, > Adjustable Output Current 60%~100% OVP, OTP > High PF up to 0.99 > Optional Dimming (0~10V, > 5 Year Warranty PWM) > IP65 for Outdoor Lighting Constant Current (CC) LED Drivers Constant Current / Constant Voltage MODELS Model① Output-C Output-V VNO-LOAD EFF(typ.) Model ① Output-C Output-V VNO-LOAD EFF(typ.) LGEU250-CV179 1400mA 143-179V 232V 90% LGEU250-CV79 3150mA 63-79V 102V 90% LGEU250-CV143 1750mA 114-143V 185V 90% LGEU250-CV72 3500mA 58-72V 93V 90% LGEU250-CV119 2100mA 95-119V 154V 90% LGEU250-CV60 4200mA 48-60V 78V 90% LGEU250-CV102 2450mA 82-102V 132V 90% LGEU250-CV50 5000mA 40-50V 65V 90% LGEU250-CV89 2800mA 71-89V 115V 90% LGEU250-CV24 8300mA 19-24V 31V 90% CHARACTERISTICS INPUT OUTPUT PROTECTION ENVIRONMENT SAFETY VOLTAGE RANGE, FREQUENCY 90-305VAC, 47~63Hz POWER FACTOR (Typ.) 0.99/110VAC, 0.96/230VAC(70~100% full load) INPUT CURRENT 1.4A/230VAC INRUSH CURRENT COLD START, 65A/230VAC OUTPUT CURRENT ADJUSTABLE 60%~100% OUTPUT VOLTAGE ADJUSTABLE ±10% LINE REGULATION ±1% LOAD REGULATION ±3% SETUP, RISE TIME 2S at full load (cold start, power on) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-150% Vout, the driver shall return to normal operation after the power is turn-on again OPERATING Temperature -35°C ~ +70°C, Humidity 10 ~ 95% RH non-condensing STORAGE Temperature -40°C ~ +85°C, Humidity 5 ~ 95% RH SAFETY STANDARDS Design refer to UL8750, UL935, UL1012, CSA-22.2 No.107.1, EN61347-1, EN61347-2-13 EMC Compliance to EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN61547 MTBF, LIFE TIME 400K hours typ. refer to MIL-HDBK-217F (25°C) CC LED drivers are designed to maintain a Constant Current during operation. A CC LED driver balances the output current from each channel to ensure reduced EMI interference and maintain the long lifetime of LEDs. The CC LED driver circuit allows the driver to operate in the ‘constant current region’ also ensuring there is no variation in the brightness of the LEDs. This means you do not have to use resistors or control the current being fed to the LEDs so they can be used in series as long as the forward voltage is within the specified output range of the LED power driver. Constant Voltage (CV) LED Drivers ① Add suffix for dimming option, “D” (0~10V), “P” (PWM) * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=100 ~ 277VAC CV LED drivers are designed to maintain a Constant Voltage during operation regardless of the current variations between 0-100%. A CV LED driver is ideal for paralleled LED lighting arrays because they generically have an in built resistor to control the current, therefore a CV driver would be required to convert the AC power to the required DC voltage. LGE SERIES MECHANICAL SPECIFICATION Dimensions in mm Weight: 1200g What is the Difference between Constant Voltage (CV) and Constant Current (CC) Drivers? With Constant Voltage the LED module only requires a fixed voltage often 12VDC or 24VDC. The current is usually regulated by either resistors that have been wired in series 78 with the LEDs or by an on board/built in regulator that the LED module may have. CV loads may be added in parallel across the output of the driver until the maximum output current is reached. This arrangement is often used in installations where the number of LED modules being connected is unknown however may provide inconsistent Led performance and reduced life. With Constant Current the reverse is true. The current is fixed by the driver whilst the voltage will vary depending on the load. The more LEDs that are attached the higher the output voltage will be up to a maximum set by the driver. This can provide uniform brightness and color behavior of the LEDs with no negative impact on LED Lifetime. How will I Know whether to Use a Constant Voltage or Constant Current Driver with my LEDs? Usually the manufacturer of the LED module will specify whether it is for use with either a Constant Voltage or Constant Current driver. You cannot run an LED module designed for CC from a CV supply without damaging it. However a CV LED load will run (albeit inefficiently) from a CC driver. Another indication is if the LED module is rated in milliamps (mA) or volts (V). Milliamps indicates a CC driver and Volts means a CV driver is required. 79 Frequently Asked Questions on LED Drivers Frequently Asked Questions on LED Drivers What are PF and PFC? What are the Differences between MTBF and Lifetime? What is 0-10V/1-10V Dimming? Mean Time Between Failure (MTBF) represents the statistical approximation of the cumulative hours a number of units should operate before a failure can be expected. It does not represent the expected life of any given unit. Used as an early fluorescent dimming system and still used today, 0-10V(1-10V) dimming has been adapted to become a reliable LED dimming control protocol. 0-10 V is one of the earliest and simplest electronic lighting control signaling systems; simply put, the control signal is a DC voltage that varies between zero and ten volts. The controlled lighting should scale its output so that at 10 V, the controlled light should be at 100% of its potential output, and at 0 V it should at the lowest possible dimming level. Power Factor (abbreviated PF) is the ratio of real power to apparent power in an AC power system and is expressed as a number between 0 and 1. Real power is the actual power drawn by the load whereas apparent power is the product of the load current and load voltage. Since the voltage and current may be out of phase this product may be significantly greater than the real power. First Number 0-No protection 1-Protected against solid objects 2-Protected against solid objects 3-Protected against solid objects 4-Protected against solid objects 5-Protected against dust, limited harmful deposit) 6-Totally protected against dust up to 50mm³ up to 12mm³ up to 2.5mm³ up to 1mm³ ingress (no Second Number PFC is the abbreviation for Power Factor Correction. In order to maintain a high power factor, switch mode power supplies (including LED drivers) must employ some form of power factor correction. This is an important issue because a load with a low power factor draws more current than a load with a high power factor for the same amount of real power transferred. Low power factor therefore results in greater power losses in the utility lines. What does IP67 Mean? IP stands for 'Ingress Protection' An IP number is used to specify the environmental protection of enclosures around electronic equipment. These ratings are determined by specific tests. The IP number is composed of two numbers, the first referring to the protection against solid objects and the second against liquids. The higher the number, the better the protection. 80 0-No protection 1-Protection against vertically falling drops of water (e.g. condensation) 2-Protection against direct sprays of water up to 15 degrees from vertical 3-Protection against direct sprays of water up to 60 degrees from vertical 4-Protection against water sprayed from all directions - limited ingress permitted 5-Protected against low pressure jets of water from all directions - limited ingress permitted 6-Protected against low pressure jets of water, limited ingress permitted (e.g. ship deck) 7-Protected against the effect of immersion be tween 15cm and 1m 8-Protected against long periods of immersion under pressure The lifetime of a product indicates how long a product should be expected to survive under normal operating conditions. It is the period of time between starting to use the device and the beginning of the wear-out phase. This is determined by the life expectancy of components used in assembly of the unit. The weakest component with the shortest life expectancy determines the life of the whole product. For power supplies, electrolytic capacitors typically have the shortest lifetime expectancy. MTBF is applicable only during the normal operating life of the product. What is THD(Total Harmonic Distortion)? The total harmonic distortion, or THD, of a signal is a measurement of the harmonic distortion present and is defined as the ratio of the sum of the powers of all harmonic components to the power of the fundamental frequency. THD is used to characterize the linearity of audio systems and the power quality of electric power systems. Distortion factor is a closely related term, sometimes used as a synonym. In power systems, lower THD means reduction in peak currents, heating, emissions, and core loss in motors What is PWM (Pulse Width Modulation) Dimming? A method most LED Drivers use to regulate the amount of power to the LED. PWM turns LEDs on and off at high frequency, reducing the total ON time to achieve a desired dimming level without visible flicker. PWM signals are sent from the LED Driver to the LED Board.