www.murata-ps.com D1U3CS-W-1300F-12-Hx4EC Series 81mm Front End AC-DC Power Converter PRODUCT OVERVIEW The D1U3CS-W-1300F-12-Hx4EC are high efficiency 1300W power factor corrected front end supplies with a 12V main output and a 5V or 3.3V (20W) standby. Active current sharing is provided to allow up to eight (8) supplies to be operated in parallel. The supplies may be hot plugged and include integral isolation devices. The power modules are fully protected from overload and overvoltage and are able to auto-recover from overtemperature faults. Status LEDS are provided on the front panel and additional control and status reporting is provided by hardware logic signals and via a PMBus™ digital interface. A low profile sub 1U height enclosure provides a power density of >23W/in3 that is ideal for delivering reliable, efficient power to servers, workstations, storage systems and other 12V distributed power systems. ORDERING GUIDE FEATURES Power Output AC Line & Temp AC Line & Temp (108-264V; 40°C) (90-264V; 50°C) Model Number Extended Power Range to 1300W 1.57" (1U) x 11.0" x 3.2" 92% efficiency at 50% FL 12VDC Main output 3.3VSB or 5VSB output (20W) >23W/in3 power density N+1 Redundancy Capable; hot plug/swap (up to 8 modules in parallel) Active current sharing on 12V main output; integral MOSFET ORING Over-Voltage, Over-Current; Over-Temperature Protection Internal variable speed cooling fans D1U3CS-W-1300F-12-HA4EC D1U3CS-W-1300F-12-HC4EC INPUT CHARACTERISTICS Parameter Voltage Operating Range Input Frequency Turn-on Input Voltage Turn-off Input Voltage Maximum Current @ VIN = 200Vac Maximum Current @ VIN = 90Vac Inrush Current Power Factor Efficiency (230Vac) excluding fan load PMBus™ Power Management Bus www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html 1 For full details go to www.murata-ps.com/rohs 1200W Conditions Ramp Up Ramp Down 1300W @ 40°C (max) 1200W @ 50°C (max) Cold start between 0 to 200ms At 230Vac; FL 20% FL 50% FL 100% FL OUTPUT VOLTAGE CHARATERISTICS Output Parameter Voltage Voltage Set Point Accuracy Line & Load Regulation Ripple & Noise1 12V Output Current (230Vac) Output Current (120Vac) Output Current (90Vac) Load Capacitance Voltage Set Point Line & Load Regulation 3.3VSB Ripple Voltage & Noise1 Output Current Load Capacitance Voltage Set Point Line & Load Regulation 5VSB Ripple Voltage & Noise1 Output Current Load Capacitance RoHS Compliant Available now at www.murata-ps.com/en/3d/acdc.html 1300W Conditions Main Output Standby Output Airflow 12V 5V 3.3V Back to Front Min 90 47 81 70.5 Typ 115/230 50/60 85 74.3 Max 264 63 89 78.0 8 15 25 Units Vac Hz Vac Arms Apk 0.99 88 92 92 Min % Typ Max 12 11.4 12.6 150 108.3 108.3 100 30,000 20MHz Bandwidth 0 3.3 3.2 3.4 100 6 10,000 20MHz Bandwidth 0 5.0 4.85 20MHz Bandwidth 0 5.1 50 4 10,000 Units Vdc mV P-P A μF Vdc mV P-P A μF Vdc mV P-P A μF Ripple and noise are measurements are to be performed with a parallel combination of a 0.1μF ceramic capacitor and 10μF tantalum capacitance on each of the power module output measurement nodes. A short coaxial cable shall be used. CB Test Certificate and Test Report www.murata-ps.com/support D1U3CS-W-1300F-12-Hx4EC.A01 Page 1 of 5 D1U3CS-W-1300F-12-Hx4EC Series 81mm Front End AC-DC Power Converter OUTPUT CHARACTERISTICS Parameter Remote Sense Output Rise (Monotonic) Startup Time Transient Response Current Sharing Accuracy (up to 8 in parallel) Hot Swap Transients Hold Up Time ENVIRONMENTAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Altitude (no derating at 40°C) Shock Sinusoidal Vibration MTBF Conditions Compensation at full load (total loop for positive & negative connections) 10% to 95% rise time AC Ramp Up PS_ON activation 12V, 50-100% step load 1A/μs 3.3/5VSB 50-100% step load 1A/μs At 100% load FL (Full Load) Conditions Non-Condensing 1200W 1300W Non-Condensing Min Max 120 No voltage excursion 1.5 2.5 150 600 165/250 ±7 5 12 Min -40 0 0 5 5 3000 Operating Operational, 2.0G; 5-500Hz Telcordia SR-332 M1C1 @ 40°C Typ Typ Max 70 50 40 90 95 30 500 Units mV s ms mV % % ms Units °C % m G K Hours CSA/UL C22.2 No.60950-1-07, Amendment 1_2011 ANSI/UL 60950-1-2011 Safety Approvals (Standards) IEC 60950-1:2005, (2nd Edition) + A1:2009 EN 60950-1:2006 + A11:2009 +A1 :2010 +A12:2011 CE Marking per LVD DIRECTIVE 2006/95/ECS Input Fusing Switching Frequency Material Flammability Weight PROTECTION CHARACTERISTICS Output Voltage Parameter N/A Over-Temperature Over-Voltage 12V (Main) Over-Current (1300W) Over-Current (1200W) Over-Voltage 3.3VSB Over-Current Over-Voltage 5VSB Over-Current ISOLATION CHARACTERISTICS Parameter Insulation Safety Rating/Test Voltage Isolation Internal 16A/250V rated fast blow in AC line 90KHz for the PFC Boost Converter 130KHZ for the Main Output Converter UL94-V0 3.15/1.43 Lbs/kg Conditions Auto re-start Latching Latching Latching Latching Auto-recovery Latching Auto-recovery Conditions Input to Output – Re-enforced Input to Chassis - Basic Output to Chassis (Ground) Min. 57 13.3 115 108 3.9 6.5 5.6 5.0 Typ. 60 Min. 3000 1500 500 Typ. Max. 63 14.5 125 118 4.3 9.0 6.0 6.5 Units °C V Max. Units Vrms Vrms Vdc A V A V A www.murata-ps.com/support D1U3CS-W-1300F-12-Hx4EC.A01 Page 2 of 5 D1U3CS-W-1300F-12-Hx4EC Series 81mm Front End AC-DC Power Converter STATUS INDICATORS Conditions Standby Rail ON; Main Output OFF; AC Present & correct LED Status Blinking Green Solid Green Blinking Amber Red Standby Rail ON; Main Output ON Main Output overcurrent; undervoltage, overvoltage warning FAN_FAULT; overtemperature; standby rail overcurrent, Main Output overcurrent or overvoltage EMISSIONS AND IMMUNITY Characteristic Input Current Harmonics ESD Immunity Radiated Field Immunity Electrical Fast Transients/Burst Immunity Surge Immunity RF Conducted Immunity Magnetic Field Immunity Standard IEC/EN 61000-3-2 IEC/EN 61000-3-3 FCC 47 CFR Part 15 CSIPR 22/EN55022 IEC/EN 61000-4-2; IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 Voltage Dips & Interruptions IEC/EN 61000-4-11 Voltage Fluctuation & Flicker Conducted Emissions Compliance Complies with Class A Limits Complies Class B Level 3; Criteria A Level 3; Criteria B Level 3; Criteria B Level 3; Criteria A Level 3; Criteria A 3A/m; Criteria B 230Vin, 100% load, Phase 0°, Dip 100% Duration 10ms (A) 230Vin, 50% load, Phase 0°, Dip 100% Duration 20ms (VSB:A, V1:A) 230Vin, 100% load, Phase 0°, Dip 100% Duration > 12ms (VSB:A, V1:B) OUTPUT CONNECTOR & SIGNAL INTERFACE DC Output and Signal Connector: FCI# 51731-057-LF D1 D2 D3 D4 D5 D6 C1 C2 C3 C4 C5 C6 B1 B2 B3 B4 B5 B6 A1 A2 A3 A4 A5 A6 PB1 PB2 PB3 PB4 PB5 PB6 NB: B4 is the shortest “last make, first break” sequenced signal pin Blade Assignment Function Description PB1, PB2, PB3 +12V GND Main Output Voltage, Return PB4, PB5, PB6 +12V OUT Main Output Voltage Signal Pin Assignment Signal Name Description An input pulled up via an internal 10K ohm to the Standby rail. When pulled low (via an open collector/drain A1 PS_ON_L drive or connection to GND) the Main Output will be turned on/enabled) A2 +12VRS_RETURN Main Output Remote Sense (-VE/Return) A3 TEMP_OK TTL compatible Logic HIGH provided when the temperature is within the allowable range of operation. Internally connected to GND; when the power module is correctly seated the corresponding mating A4 PS_SEATED connector pin is grounded and therefore allows detection that the power module is in situ. A5, B5, C5, D5 +VSB Standby Voltage Output A6, B6, C6, D6 +VSB GND Standby Voltage Output, Return/GND B1 AC_OK Incoming AC Source voltage “OK” (present and within operational limits) B2 +12VRS Main 12V output remote sense line B3 +12V_ISHARE Main 12V output current share bus B4 C1 C2 This is the shortest “last make, first break” (last to mate in the sequence). If left open circuit then the main output will be inhibited (no output). PS_INHIBIT/PS_KILL When inserted in to the system slot this pin must be pulled “low” by the system to enable (turn on) the Main output and only after all other pins are connected and the power module is correctly seated. SDA SCL I2C Serial Data Line I2C Serial Clock Line Current (Amps per Pin) 30 30 N/A N/A N/A 2.0 2.0 N/A N/A N/A N/A N/A N/A www.murata-ps.com/support D1U3CS-W-1300F-12-Hx4EC.A01 Page 3 of 5 D1U3CS-W-1300F-12-Hx4EC Series 81mm Front End AC-DC Power Converter Signal Pin Assignment C3 C4 D1 D2 D3 D4 Signal Name PWR_GD FAN_FAIL A0 A1 S_INT N/A MATING CONNECTOR Supplier FCI Description Power Good signal. An active TTL HIGH signifies when the output is within regulation limits. Fan Fail signal (failure or locked rotor) I2C LSB (Least Significant Bit) Address Line I2C MSB (Most Significant Bit) Address Line System Interrupt Reserved; no end user connection Press Fit, Straight --- Press Fit, Right Angle 51761-10002406AA Solder Straight --- Current (Amps per Pin) N/A N/A N/A N/A N/A N/A Solder Right Angle --- WIRING DIAGRAM FOR OUTPUT Dotted lines show optional remote sense connections. Optional remote sense lines can be attached to a load that is a distance away from the power supply to improve regulation at the load. +12VRS (Main Output Remote Sense) B2 PB4-6 +12VRS (Main Output Remote Sense) +12V OUT +12V OUT PB4-6 B2 12V load D1U3CS PB1-3 A2 B3 A5,B5,C5,D5 A1 A6,B6,C6,D6 B4 D1U3CS +12V GND +12V GND +12VRS_RETURN +12V_ISHARE A2 +12V_ISHARE B3 PS_ON_L PS_ON_L +VSB GND +12VRS_RETURN +VSB +VSB PB1-3 A5,B5,C5,D5 A1 +VSB load FET, BJT, wire or switch (debounced ) to turn on +12V main output +VSB GND A6,B6,C6,D6 PS_INHIBIT/PS_KILL PS_INHIBIT/PS_KILL B4 CURRENT SHARING NOTES 1. Main 12VDC Output: Analogue active share bus. The ISHARE bus (Pin B3) must be connected on all sharing modules. It is not required that the SENSE signals are connected to the remote load for current share to operate correctly. 2. Up to eight (8) power modules can be connected in parallel (non-redundant) or N+1 configuration. The current share bus is analogue bi-directional (can source or sink current from the ISHARE bus). The voltage of the bus would measure 8VDC for a single power module at 100% load; for two (2) modules sharing a common load the ISHARE bus voltage would be 4V for a perfect 50/50 current share scenario. 3. VSTANDBY output power modules can also be connected in parallel and have internal output isolation devices; however the combined available power is limited to that available from a single power module (3.3V or 5V; 20W) irrespective of the number of modules connected in parallel. www.murata-ps.com/support D1U3CS-W-1300F-12-Hx4EC.A01 Page 4 of 5 D1U3CS-W-1300F-12-Hx4EC Series 81mm Front End AC-DC Power Converter MECHANICAL DIMENSIONS Direction of Airflow AC Input Connector/Inlet: IEC 60320-C14 Dimensions: 3.20" x 11.00" x 1.57" [81.3mm x 279.4mm x 39.9mm] OPTIONAL ACCESSORIES Description D1U3CS-12 Output Interface Connector Card Part Number D1U3CS-12-CONC APPLICATION NOTES Document Number ACAN-41 ACAN-49 Description D1U3CS-12-CONC Output Interface Connector Card D1U3CS-12 Communications Protocol Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED Link www.murata-ps.com/data/apnotes/acan-41.pdf www.murata-ps.com/data/apnotes/acan-49.pdf This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2014 Murata Power Solutions, Inc. www.murata-ps.com/support D1U3CS-W-1300F-12-Hx4EC.A01 Page 5 of 5