www.murata-ps.com D1U86P-W-1600-12-HBxDC Series 86mm 1U Front End AC-DC Power Supply PRODUCT OVERVIEW The D1U86P-W-1600-12-HBxDC products are high efficiency 1600 watt, power factor corrected front end supplies with a 12V main output and a 12V (30W) standby. They have current sharing and up to 8 supplies may be operated in parallel. The supplies may be hot plugged, they recover from overtemperature faults, and have logic and PMBus monitoring and control. Their low profile 1U package and >38.6W/cubic inch power density make them ideal for delivering reliable, efficient power to servers, workstations, storage systems and other 12V distributed power systems. ORDERING GUIDE Power Output; AC Line (90-264V) (108-264V) (180-264V) Part Number FEATURES D1U86P-W-1600-12-HB4DC D1U86P-W-1600-12-HB3DC 1600W output power 94% minimum efficiency at 50% load 1200W 1350W Main Output Standby Output Airflow 12V 12V Back to front Front to Back 1600W INPUT CHARACTERISTICS 12V main output Parameter Input Voltage Operating Range Frequency Turn-on Voltage Turn-off Voltage Maximum Input Current Inrush Current Power Factor 12V standby output of 30W 1U height: 3.4" x 7.75" x 1.59" 38.6 Watts per cubic inch density N+1 redundancy, including hot plugging (up to 8 in parallel) Current sharing on 12V main output Efficiency (230Vac) excluding fan load Overvoltage, overcurrent, overtemperature protection Internal cooling fan (variable speed) Min. 90 47 81 70.5 Ramp up Ramp down 1200W, 100Vac At 264Vac at 25°C cold start At 230Vac, half load 20% load 50% load 100% load Nom. 115/230 50/60 73 Max. 264 63 89 78 14.1 35 Units Vac Hz Vac Arms Apk 0.98 90 94 91 % OUTPUT VOLTAGE CHARACTERISTICS PMBus™ / I²C interface monitoring and control Output Voltage RoHS compliant 12V 12VSB www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html Conditions Parameter Conditions Min. Typ. Max. Voltage Set Point Line and Load Regulation Droop Ripple Voltage & Noise1 Output Current (230 Vac)2 Output Current (120 Vac)2 Output Current (100 Vac)2 Load Capacitance Voltage Set Point Ripple Voltage & Noise1 Output Current 50% load 12.17 11.4 12.2 12.23 12.6 3.10 20MHz Bandwidth 0 0 0 50% load 20MHz Bandwidth 11.97 0 12.0 120 133.4 112.5 100.0 10,000 12.02 120 2.5 Units Vdc mV/A mV p-p A A A μF Vdc mV p-p A 1 Ripple and noise measured with a parallel combination of a 1.0μF ceramic and 10μF tantalum capacitor on each of the power module outputs. A short coaxial cable connected directly to the input of a scope is required. 2 To meet ripple and transient step load specifications a minimum load of 4A is required. Available now at http://power.murata.com/en/3d/acdc.html CB Test Certificate and Test Report For full details go to www.murata-ps.com/rohs www.murata-ps.com/support D1U86P-W-1600-12-HBxDC.A01 Page 1 of 6 D1U86P-W-1600-12-HBxDC Series 86mm 1U Front End AC-DC Power Supply OUTPUT CHARACTERISTICS Parameter Output Rise Monotonicity Startup Time Transient Response Current sharing accuracy (up to 8 in parallel)3 Hot Swap Transients Holdup Time 3 Conditions No voltage excursion AC ramp up 12V, 50% load step, 1.0Aμs di/dt 12VSB, 50% load step,1.0Aμs di/dt At 100% load All outputs remain in regulation At full load Min. Typ. Max. Units 1.5 600 600 3 s mV ±5 5 12 % % ms Load current of 100% applies to each power module max load connected in an N+1 configuration; therefore the total load will be “N” x 100% . The share accuracy of ±5% is a fixed percentage irrespective of total loading and number of units connected in parallel. ENVIRONMENTAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Altitude (without derating at 45°C) Shock Vibration MTBF Acoustic Safety Approvals Input Fuse Weight Conditions Noncondensing 30G non operating 10-500Hz, 0.5G (non-operational) Per Telcordia SR-322 M1C1@ 40°C Min. -40 0 5 5 3000 Typ. Max. 85 55 90 95 Units °C % m 559K 65 hrs dBA/@1m CSA 60950-1-07+A1:2011 ANSI/UL 60950-1-2011, Second Edition IEC 60950-1:2005 (2nd Edition) + A1:2009 EN 60950-1:2006 +A11:2009 +A1:2010 Power Supply has internal 16A/250V fast blow fuse on the AC line input 2.33/1.06 lbs/Kg PROTECTION CHARACTERISTICS Output Voltage Parameter Conditions Overtemperature (intake) An OTP warning will be issued via the PMBus™ interface when the air inlet exceeds 65°C; however the power module shall not shut down until critical internal hotspot temperatures are exceeded. Overvoltage Overcurrent at 220Vac 12V Overcurrent at 120Vac 12VSB Overvoltage Overcurrent Min. Typ. Max. 65 Units °C Latching Shutdown of the output followed by auto- recovery after one second. The output shall attempt three such auto-recovery attempts and then enter a permanent latched state. Recovery of the permanent latched state shall require cycling of the incoming AC source or toggling of the PSON# signal. Latching Autorecovery 13.2 14.4 140 153 Conditions Input to Output - Reinforced Input to Chassis - Basic Output to Chassis 1.5mA at 264Vac, 50/60Hz Min. 3000 1500 500 V A 118 129 13.2 2.75 14.4 3 V A Max. Units Vrms Vrms Vdc ISOLATION CHARACTERISTICS Parameter Insulation Safety Rating / Test Voltage Isolation Leakage Current Typ. www.murata-ps.com/support D1U86P-W-1600-12-HBxDC.A01 Page 2 of 6 D1U86P-W-1600-12-HBxDC Series 86mm 1U Front End AC-DC Power Supply EMISSIONS AND IMMUNITY Characteristic Input Current Harmonics Voltage Fluctuation and Flicker Conducted Emissions ESD Immunity Radiated Field Immunity Electrical Fast Transient Immunity Surge Immunity Radiated Field Conducted Immunity Magnetic Field Immunity Standard IEC/EN 61000-3-2 IEC/EN 61000-3-3 FCC 47 CFR Part 15/CISPR 22/EN55022 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 Voltage dips, interruptions IEC/EN 61000-4-11 Compliance Complies Complies Class A, 6dB margin Level 3 criteria A Level 3 criteria B Level 3 criteria A Level 3 criteria A Level 3 criteria A 3 A/m criteria B 230Vin, 100% load, Phase 0°, Dip 100% Duration 10ms (A) 230Vin, 50% load, Phase 0°, Dip 100% Duration 20ms (VSB:A, V1:A) 230Vin, 100% load, Phase 0°, Dip 100% Duration > 20ms (VSB, V1:B) STATUS INDICATORS AND CONTROL SIGNALS Signal Description PSON# Low = main output on; PSON# can be permanently tied to GND within the host system. Short pin pulled down on p/s; pulled up to either 3.3V or 12V (max) in the host system. For 3.3V use a 5.11KΩ resistor; for 12V, use a 21KΩ resistor. Open drain PMBus™ signal; can be left open if not used. PMBus™ Address; ADDR can be grounded or left open if not used. If grounded, the address will be 000, if it is open, the default address will be 111. Analog representation of main output current; can be left open if not used. A three level signal based on AC input and DC output status; can be left open if not used. I2C clock I2C data Mode Operating Condition AC Turn-off AC Input is below minimum power-supply turn-on specification Standby Power supply standby output is operating within normal parameters and main output is disabled Power-good Power supply standby & main outputs are operating within normal parameters and delivering power Warning Warning condition in power supply has been detected Fault Fault condition in power supply has been detected. PRESENT# PS INTERRUPT ADDR ISHARE PSOK4 I2C CLOCK I2C DATA LED State 1. Off 2. Green – blinking 1Hz 3. Green – solid 4. Yellow – blinking 1Hz 5. Yellow – solid 3 See truth table below for operation. OUTPUT CONNECTOR AND SIGNAL SPECIFICATION Pin# 14-26, 39-51 1-13, 52-64 37 Function RTN 12V 12VSB Pin Type Power Ground Power Power 38 PSINTERRUPT Output 36 PRESENT# Input 35 PSOK Analog output 34 ISHARE Analog I/O 33 32 31 30 29 28 27 PSON# SCL SDA GND N/A N/A ADDR Input Input I/O Analog I/O N/A N/A Analog input Description Power and Standby Return 12V Output 12V Standby Output Active low; interrupt line for power supply fault & warning detection as per PMBus spec Power Supply Present Signal (shortest pin) Combination of there power supply output indicator signals: 1. AC input OK 2. Power Good 3. Power Supply Fault Analog representation of main output current. Typical analog voltage shall be 60.15mV/Amp of main output current. Power Supply on/off control signal SMBus/PMBus Clock SMBus/PMBus Data Power Supply Signal Ground Reserved; no User connection Reserved; no User connection PMBus Address Power Supply Output Card Edge PCB Top Side 64 1 33 32 PCB Bottom Side www.murata-ps.com/support D1U86P-W-1600-12-HBxDC.A01 Page 3 of 6 D1U86P-W-1600-12-HBxDC Series 86mm 1U Front End AC-DC Power Supply CONNECTOR AND SIGNAL SPECIFICATION4 PSOK TRUTH TABLE VS. ANALOG OUTPUT DC_OK_H 0 0 1 1 X PWR_GOOD_H 0 1 0 1 X PS_FAULT_L 1 1 1 1 0 PSOK < 0.1Vdc (1/3) VDD (2/3) VDD VDD 0.2-0.4Vdc VDD = 3.3Vdc OPERATION MODE No DC Input Invalid Standby Power Good PS Fault DERATING CURVES Main Output current (Adc) Output Current Derating vs. Ambient Temperature (back to front airflow) D1U86P‐W‐1600‐HB4DC; VSB 1.0A 12Vdc @90Vac ‐ 113A to 45°C; derates to 90A at 50°C 140 120 100 80 90V 60 120V 40 180V + 20 0 25 30 35 40 45 50 55 Ambient Temperature (°C) Output Current Derating vs. Ambient Temperature (front to back airflow) D1U86P‐W‐1600‐12‐HB3DC; VSB 2.5A (No Derating) Main Output current (Adc) 140 120 100 80 90V 60 120V 40 180V+ 20 0 25 30 35 40 45 50 55 Ambient Temperature (°C) www.murata-ps.com/support D1U86P-W-1600-12-HBxDC.A01 Page 4 of 6 D1U86P-W-1600-12-HBxDC Series 86mm 1U Front End AC-DC Power Supply WIRING DIAGRAM FOR OUTPUT 1-13, 52-64 1-13, 52-64 Main output load 14-26, 39-51 D1U86 RTN RTN 14-26, 39-51 37 33 D1U86 12VSB 12VSB 37 PSON# PSON# 33 VSB load FET,BJT,wire or switch (debounced) to turn on 12V main output RTN FET,BJT,wire or switch (debounced) to turn on 12V main output RTN CURRENT SHARING NOTES Main Output: Current share is achieved using the droop method. Nominal output voltage (12.20V) is achieved at 50% load and output voltage droops at a rate of 3.10mv per amp increase. Startup of parallel power supplies is not internally synchronized. If more than 1600W combined power is needed, start-up synchronization must be provided by using a common PS_ON signal. To account for ±5% full load current sharing accuracy and the reduction in full load output voltage due to droop, available output power must be derated by 10% when units are operated in parallel. Standby output can be tied together for redundancy but total combined output power must not exceed 30W, Internal MOSFET ORING devices are used www.murata-ps.com/support D1U86P-W-1600-12-HBxDC.A01 Page 5 of 6 D1U86P-W-1600-12-HBxDC Series 86mm 1U Front End AC-DC Power Supply MECHANICAL DIMENSIONS 197.70±0.65 137.70 REF 16.50±0.30 39.90±0.50 3.00±0.25 9.00±0.30 240.75 REF 51.36±0.30 83.52±0.30 8.00±0.30 3.30±0.25 198.05±0.65 190.90±0.65 2X3.20±0.25 1.41 ±0.50 AIR FLOW DIRECTION FRONT TO BACK AIR FLOW DIRECTION BACK TO FRONT 0.062" 40.50±0.50 6.80±0.40 86.40±0.60 10.25±0.40 4.20±0.40 9.56±0.25 191.70±0.50 AC input connector: IEC 320-C14 3.4" x 7.78" x 1.59" [86.4mm x 197.7mm x 40.5mm] MATING CONNECTOR Part Number Description FCI 10053363-200LF FCI 10046971-001LF Right Angle Vertical OPTIONAL ACCESSORIES Description Part Number 12V D1U86P Output Connector Card D1U86P-12-CONC APPLICATION NOTES Document Number Description ACAN-50 D1U86P Output Connector Card ACAN-51 D1U86P Communication Protocol Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2015 Murata Power Solutions, Inc. www.murata-ps.com/support D1U86P-W-1600-12-HBxDC.A01 Page 6 of 6