D1U2-D-400-12-HA4C www.murata-ps.com 54mm 1U Front End DC-DC Power Supply Converter PRODUCT OVERVIEW The D1U2-D-400-12-HA4C is a 400 watt, DC input, isolated front end power supply with a 12V main output and a 5V (15W) standby. It features active current sharing for 2 supplies operated in parallel. The supply may be hot plugged, it recovers from overtemperature faults, and has status LEDs on the front panel in addition to logic and PSMI status signals. The supply comes in a low profile 1U package and has >8W/cubic inch power density, making it ideal for delivering reliable, efficient power to servers, workstations, storage systems and other 12V distributed power systems. ORDERING GUIDE Part Number FEATURES 400W output power Power Output High Line AC Power Output Low Line AC Main Output Standby Output Airflow 400W 400W 12 5V Back to front D1U2-D-400-12-HA4C 12V main output INPUT CHARACTERISTICS 5V standby output of 15W Parameter Voltage Operating Range Turn-on Input Voltage Turn-off Input Voltage Maximum current at Vin=-40Vdc DC Inrush Current 1U height: 2.15"x13.67"x1.58" 8.6 Watts per cubic inch density Efficiency 83% at full load, 48Vdc and 50°C N+1 redundancy capable, including hot plugging (2 in parallel) Active current sharing on 12V main output, ORing FET Overvoltage, overcurrent, overtemperature protection Internal cooling fan (variable speed) Efficiency (-40Vdc to -72Vdc) including fan load Conditions Min. -40 -43 -38.5 Ramp up Ramp down 400W Cold start between 0 to 200msec 35% load 50% load 100% load Nom. -48 -43.5 -39 Max. -72 -44 -39.5 15 30 80 80 83 Units Vdc A Apk % OUTPUT VOLTAGE CHARACTERISTICS Output Voltage PSMI and SMbus / I2C interface with bicolor LED status indicators RoHS compliant 12V 5VSB 1 Parameter Conditions Voltage Set Point Line and Load Regulation Ripple Voltage & Noise1 Output Current Load Capacitance Voltage Set Point Line and Load Regulation Ripple Voltage & Noise1 Output Current Load Capacitance Min. Typ. Max. 12.0 11.8 20MHz Bandwidth 0 0 20MHz Bandwidth 0 0 Vdc 12.2 120 33.3 15,000 mV p-p A μF 5.15 50 3 500 mV p-p A μF 5.0 4.85 Units Vdc Ripple and noise are measured with 0.1 μF of ceramic capacitance and 10 μF of tantalum capacitance on each of the power supply outputs. A short coaxial cable with 50Ω scope termination is used. www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html www.murata-ps.com/en/3d/acdc.html Available now at www.murata-ps.com/en/3d/acdc.html CB Test Certificate and Test Report For full details go to www.murata-ps.com/rohs www.murata-ps.com/support CPS_D1U2-D-400-12-HA4C.A04 Page 1 of 6 D1U2-D-400-12-HA4C 54mm 1U Front End DC-DC Power Supply Converter OUTPUT CHARACTERISTICS Parameter Output Rise Monotonicity Startup Time Transient Response Conditions No voltage excursion DC ramp up 12V, 30-70% load step, 1A/μs di/dt 5VSB, 30-70% load step, 0.1A/μs di/dt Current sharing accuracy (up to 2 in parallel) At 100% load Hot Swap Transients Holdup Time All outputs within regulation Min. Typ. Max. Units 1.5 2.0 3 3 s % ±10 8 ms ENVIRONMENTAL CHARACTERISTICS Parameter Storage Temperature Range Operating Temperature Range Operating Humidity Storage Humidity Altitude (without derating at 55°C) Shock Operational Vibration MTBF Safety Approvals Input Fuse Switching Frequency Weight Conditions Min. -40 0 10 5 Noncondensing Typ. Max. 70 50 90 95 3,000 30G non operating 0.5G, 5 – 500 Hz Per Telcordia SR332M1C1 @25°C 300K CSA/UL 60950-1-07-2nd Ed. IEC 60950-1:2005 (2nd Edition) EN 60950-1:2006 +A11 CE Marking per LV DIRECTIVE 2006/95/EC Power Supply has internal 20A/125V fast blow fuses on both DC lines 200KHz for Main Output Converter 2.01lbs (0.912kg) Units °C % m hrs PROTECTION CHARACTERISTICS Output Voltage 12V 5VSB Parameter Conditions Min. Typ. Max. Units Overtemperature (intake) Overvoltage Overcurrent Overvoltage Overcurrent Autorestart Latching Hiccup Latching Autorecovery 65 14.0 115 5.7 4.4 70 75 14.5 130 5.9 6.0 °C V % V A Conditions Input to Output - Basic Input to Chassis - Basic Output to Chassis Min. 1500 1000 500 Typ. Max. Units Vdc Vdc Vdc ISOLATION CHARACTERISTICS Parameter Insulation Safety Rating / Test Voltage Isolation CONTROL SIGNALS Condition LED Status Standby - ON; Main output - OFF; DC PRESENT Standby - ON; Main output - ON Main/standby output overcurrent, undervoltage, overvoltage warning FAN_FAULT; overtemperature; stand-by overcurrent, undervoltage Blinking green Solid green Blinking yellow Yellow www.murata-ps.com/support CPS_D1U2-D-400-12-HA4C.A04 Page 2 of 6 D1U2-D-400-12-HA4C 54mm 1U Front End DC-DC Power Supply Converter EMISSIONS AND IMMUNITY Characteristic Standard Compliance Conducted Emissions ESD Immunity Radiated Field Immunity Electrical Fast Transients/Burst Immunity Surge Immunity Radiate Field Conducted Immunity Magnetic Field Immunity FCC 47 CFR Part 15/CISPR 22/EN55022 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 IEC/EN 61000-4-6 IEC/EN 61000-4-8 Class B Level 3 criteria A Level 3 criteria B Level 3 criteria B Level 2 criteria A Level 3 criteria A 3 A/m criteria B DC OUTPUT CONNECTOR AND SIGNALS The DC Output Connector is a TYCO MINIPAK HDL Connector TYCO P/N: 1926734-1. Mating pin sequencing shall be 12V_RTN first, 12V second, signals third and PSKILL_L signal last. PSKILL_L is the last to mate and first to break and is used as a power supply output enable for the 12V rail. Mating Part: TYCO PN 1-1926739-8 Power Supply Output Connector Isometric and Front Views Front Connector View Looking at Blades and Pins (view looking in at rear of power supply) www.murata-ps.com/support CPS_D1U2-D-400-12-HA4C.A04 Page 3 of 6 D1U2-D-400-12-HA4C 54mm 1U Front End DC-DC Power Supply Converter DC OUTPUT CONNECTOR AND SIGNALS (continued) View into mating face of 25S8P MINIPAK HDL Plug Row: Column: 1 2 3 4 5 1 2 3 4 5 6 7 8 e d c b a Signal contacts: choice of Level 1 (L1) or Level 2 (L2) Power contacts: choice of Level 2 (L2) or Level 3 (L3) POWER SUPPLY OUTPUT CONNECTOR POWER BLADE AND SIGNAL PIN ALLOCATION Power Blade Number Signal Function P1, P2, P3, P4 P5, P6, P7, P8 A1 A2 A3 A4, A5 B1 B2, B3 B4, B5 C1 C2, C3, C4, C5 D1 D2 D3 D4 D5 E1 E2 E3 E4 E5 RTN 12V SMB_ALERT_L PSON_L PSKILL_L 5VSB SMB_SCL RTN 5VSB SMB_SDA RTN SMB_A1 RTN 12LS 12V_RS12V_RS+ SMB_A0 RTN PWOK_H FF1_H RTN 12V Return 12V Output I2C Serial Bus Interrupt Power Supply ON Power Supply Enable 5V Standby Voltage I2C Serial Bus Clock Ground 5V Standby Voltage I2C Serial Bus Data / Address Ground I2C Serial Bus Address Bit A1 Ground 12V Current Share Line 12V Remote Sense Negative 12V Remote Sense Positive I2C Serial Bus Address Bit A0 Ground Power OK Status Bit Fan Fail #1 Status Output Ground Signal Direction Blade Sequencing Output Output Output Input Input Output Bi-directional Level 3 UPM PWR Level 2 UPM PWR Level 2 Signal Level 1 Signal Level 2 Signal Level 2 Signal Output Bi-directional Output Input Output Bi-directional Level 2 Signal Level 2 Signal Input Input Output Level 2 Signal www.murata-ps.com/support CPS_D1U2-D-400-12-HA4C.A04 Page 4 of 6 D1U2-D-400-12-HA4C 54mm 1U Front End DC-DC Power Supply Converter WIRING DIAGRAM Dotted lines show optional remote sense connections. Optional remote sense lines can be attached to a load that is a distance away from the power supply to improve regulation at the load. +Remote Sense D5 +Remote Sense +DC out +DC out P5-P8 P5-P8 D5 12V load D1U2 P1-P4 D4 D3 A4, A5, B4, B5 A2 DC out return -Remote Sense -Remote Sense 12LS 12LS 5VSB 5VSB PSON_L PSON_L Close switch (or FET, BJT, or wire) to turn on +DC out B2, B3, C2-C5, D2, E2, E5 A3 D1U2 DC out return RTN P1-P4 D4 D3 A4, A5, B4, B5 A2 +5V logic circuitry RTN B2, B3, C2-C5, D2, E2, E5 PSKILL_L PSKILL_L A3 CURRENT SHARING NOTES 12V Output: Current sharing is achieved using the active current share method. (See wiring diagram section for connection details.) The total combined load must be below 400W at startup. Startup of parallel power supplies is not internally synchronized. It is recommended that the paralleled power supplies be turned on at the same time (with their PSON_L signals). Current sharing can be achieved with or without remote sense connected to the common load. 5VSB Output: 5VSB outputs can be tied together for redundancy but total combined output power must not exceed 15W. The 5VSB output has internal ORing MOSFET for additional redundancy / internal short protection. Up to 2 units can be paralleled together. Outputs of AC input units (D1U2-W-400) and DC input units (D1U2-D-400) can be paralleled together. Please consult your Murata sales representative if operation with more than two units in parallel is needed. www.murata-ps.com/support CPS_D1U2-D-400-12-HA4C.A04 Page 5 of 6 D1U2-D-400-12-HA4C 54mm 1U Front End DC-DC Power Supply Converter MECHANICAL DIMENSIONS [1] 347.20 ±0.50 13.669 ±0.020 [1] 54.50 ±0.50 2.146 ±0.020 33.00 1.299 REF [1] 340.40 ±0.50 13.402 ±0.020 380.20 14.969 REF [1] 66.55 ±0.50 2.620 ±0.020 MATTING SURFACE OF SIGNAL PINS FIELD MATTING SURFACE OF SIGNAL PINS FIELD 8.15 ±0.35 0.321 ±0.014 38.54 1.517 REF 9.41 ±0.35 0.370 ±0.014 [1] 40.20 ±0.50 1.583 ±0.020 [1] 26.16 ±1.00 1.030 ±0.039 [1] 39.00 ±0.50 1.535 ±0.020 Airflow Back to Front DC input connector: Phoenix 1804807 Mating Part: Phoenix PN 1848902 or 1804917 Dimensions: 2.15" x 13.67" x 1.58" [54.5mm x 347.2mm x 40.2mm] OPTIONAL ACCESSORIES Description Part Number 12V D1U2 Output Connector Card D1U2-12-CONC APPLICATION NOTES Document Number Description TBD D1U2 Output Connector Card TBD D1U2 Communication Protocol Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. ISO 9001 and 14001 REGISTERED This product is subject to the following operating requirements and the Life and Safety Critical Application Sales Policy: Refer to: http://www.murata-ps.com/requirements/ Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. © 2013 Murata Power Solutions, Inc. www.murata-ps.com/support CPS_D1U2-D-400-12-HA4C.A04 Page 6 of 6