X93154 ® Low Noise, Low Power, 32 Taps Data Sheet Digitally Controlled Potentiometer (XDCP™) FN8180.3 Features • Solid-State Potentiometer The Intersil X93154 is a digitally controlled potentiometer (XDCP). The device consists of a resistor array, wiper switches, a control section, and nonvolatile memory. The wiper position is controlled by a 3-wire interface. The potentiometer is implemented by a resistor array composed of 31 resistive elements and a wiper switching network. The position of the wiper element is controlled by the CS, U/D, and INC inputs. The position of the wiper can be stored in nonvolatile memory and then be recalled upon during a subsequent power-up operation. The device is connected as a two-terminal variable resistor and can be used in a wide variety of applications including: - Bias and Gain Control - LCD Contrast Adjustment February 19, 2008 • 3-Wire Serial Interface • 32 Wiper Tap Points - Wiper Position Stored in Nonvolatile Memory and Recalled on Power-up • 31 Resistive Elements - Temperature Compensated - Maximum Resistance Tolerance of ±30% - Terminal Voltage, 0 to VCC • Low Power CMOS - VCC = 3V±10% - Active Current, 250µA max. - Standby Current, 1µA max. • High Reliability - Endurance 200,000 Data Changes Per Bit - Register Data Retention, 100 years • RTOTAL Value = 50kΩ • Packages - 8 Ld MSOP, TDFN • Pb-free Available (RoHS Compliant) Pinouts X93154 (8 LD TDFN) TOP VIEW X93154 (8 LD MSOP) TOP VIEW INC 1 8 VCC U/D 2 7 CS RH 3 6 RL VSS 4 5 NC* INC 1 8 VCC U/D 2 7 CS RH 3 6 RL VSS 4 5 NC* *NC can be left unconnected, or connected to any voltage between V SS and VCC 1 CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 1-888-468-3774 | Intersil (and design) is a registered trademark of Intersil Americas Inc. XDCP is a trademark of Intersil Americas Inc. Copyright Intersil Americas Inc. 2004, 2005, 2008. All Rights Reserved All other trademarks mentioned are the property of their respective owners. X93154 Ordering Information PART NUMBER PART MARKING PKG. DWG. # VCC LIMITS (V) RTOTAL (kΩ) TEMP RANGE (°C) PACKAGE 3 ±10% 50 -40 to +85 8 Ld MSOP M8.118 X93154UM8I-3* AGK X93154UM8IZ-3* (Note) AIW -40 to +85 8 Ld MSOP (Pb-free) M8.118 X93154UU8IZ-3* (Note) AKH -40 to +85 8 Ld TDFN (Pb-free) L8.2.5x2 *Add "T1" suffix for tape and reel. Please refer to TB347 for details on reel specifications. NOTE: These Intersil Pb-free plastic packaged products employ special Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate PLUS ANNEAL - e3 termination finish, which is RoHS compliant and compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-020. Block Diagram VCC (SUPPLY VOLTAGE) U/D INC CS 30k 5-BIT UP/DOWN COUNTER 30 29 RH UP/DOWN (U/D) 5-BIT NONVOLATILE MEMORY CONTROL AND MEMORY INCREMENT (INC) RH 31 DEVICE SELECT STORE AND CONTROL RECALL CIRCUITRY (CS) RL 28 ONE OF THIRTY TWO DECODER TRANSFER GATES RESISTOR ARRAY 2 1 VCC 0 VSS (Ground) VSS RL GENERAL DETAILED Pin Descriptions MSOP, TDFN SYMBOL BRIEF DESCRIPTION 1 INC Increment (INC). The INC input is negative-edge triggered. Toggling INC will move the wiper and either increment or decrement the counter in the direction indicated by the logic level on the U/D input. 2 U/D Up/Down (U/D). The U/D input controls the direction of the wiper movement and whether the counter is incremented or decremented. 3 RH RH. The RH and RL pins of the X93154 are equivalent to the fixed terminals of a mechanical potentiometer. The minimum voltage is VSS and the maximum is VCC. The terminology of RH and RL references the relative position of the terminal in relation to wiper movement direction selected by the U/D input. 4 VSS Ground. 5 NC No Connection (or can be connected to any voltage between VSS and VCC.) 6 RL RL. The RH and RL pins of the X93154 are equivalent to the fixed terminals of a mechanical potentiometer. The minimum voltage is VSS and the maximum is VCC. The terminology of RH and RL references the relative position of the terminal in relation to wiper movement direction selected by the U/D input. 7 CS Chip Select (CS). The device is selected when the CS input is LOW. The current counter value is stored in nonvolatile memory when CS is returned HIGH while the INC input is also HIGH. After the store operation is complete, the X93154 will be placed in the low power standby mode until the device is selected once again. 8 VCC Supply Voltage. 2 FN8180.3 February 19, 2008 X93154 Absolute Maximum Ratings Thermal Information Voltage on CS, INC, U/D, RH, RL and VCC with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +6.5V Maximum Resistor Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2mA Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C Pb-free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . .see link below http://www.intersil.com/pbfree/Pb-FreeReflow.asp Recommended Operating Conditions Temperature Range Industrial. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C Supply Voltage VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3V ±10% (Note 6) CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and result in failures not covered by warranty. NOTES: 1. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage = (VH(n)(actual)-VH(n)(expected)) = ±1 Ml Maximum. n = 1.. 29 only 2. Relative linearity is a measure of the error in step size between taps = VH(n+1)-[VH(n) + Ml] = ±0.5 Ml, n = 1 .. 29 only. 3. 1 Ml = Minimum Increment = RTOT/31. 4. Typical values are for TA = +25°C and nominal supply voltage. 5. Limits established by characterization and are not production tested. 6. When performing multiple write operations, VCC must not decrease by more than 150mV from its initial value. 7. Parts are 100% tested at +25°C. Over-temperature limits established by characterization and are not production tested. Potentiometer Specifications MIN (Note 7) TYP (Note 4) MAX (Note 7) UNIT End-to-End Resistance 35 50 65 kΩ RH, RL Terminal Voltages 0 VCC V 1 mW (Note 5) SYMBOL RTOT VR Over recommended operating conditions unless otherwise stated. PARAMETER TEST CONDITIONS/NOTES Power Rating RTOTAL = 50kΩ Noise Ref: 1kHz RW Wiper Resistance (Note 5) 1000 Ω IW Wiper Current (Note 5) 0.6 mA -120 Resolution CH/CL/CW 3 Absolute Linearity (Note 1) VH(n)(actual)-VH(n)(expected) Relative Linearity (Note 2) VH(n+1)-[VH(n)+MI] RTOTAL Temperature Coefficient (Note 5) Potentiometer Capacitances See “Circuit #2 SPICE Macro Model” on page 4 DC Electrical Specifications SYMBOL PARAMETER TEST CONDITIONS VCC Active Current (Increment) CS = VIL, U/D = VIL or VIH and INC = 0.4V @ max. tCYC ICC2 VCC Active Current (Store) (EEPROM Store) CS = VIH, U/D = VIL or VIH and INC = VIH @ max. tWR Standby Supply Current CS = VCC - 0.3V, U/D and INC = VSS or VCC - 0.3V 3 % ±1 MI (Note 3) ±0.5 MI (Note 3) ±35 ppm/°C 10/10/25 pF (Note 5) Over recommended operating conditions, unless otherwise specified. ICC1 ISB dBV (Note 5) MIN (Note 7) TYP (Note 4) MAX (Note 7) UNIT 50 250 µA 600 µA 1 µA FN8180.3 February 19, 2008 X93154 DC Electrical Specifications SYMBOL Over recommended operating conditions, unless otherwise specified. (Continued) PARAMETER MIN (Note 7) TEST CONDITIONS TYP (Note 4) MAX (Note 7) UNIT ±1 µA 150 µA ±1 µA ILI CS VIN = VCC ILI CS VCC = 3V, CS = 0 ILI INC, U/D Input Leakage Current VIN = VSS to VCC VIH CS, INC, U/D Input HIGH Voltage VCC x 0.7 VCC + 0.5 V VIL CS, INC, U/D Input LOW Voltage -0.5 VCC x 0.1 V CIN (Note 5) CS, INC, U/D Input Capacitance 10 pF 100 VCC = 3V, VIN = VSS, TA = +25°C, f = 1MHz Circuit #2 SPICE Macro Model Endurance and Data Retention PARAMETER MIN UNIT Minimum endurance 200,000 Data changes per bit Data retention 60 100 RTOTAL RH Years CH Test Circuit #1 CL CW RL 10pF 25pF TEST POINT 10pF VH/RH AC Conditions of Test VL AC Electrical Specifications SYMBOL Input pulse levels 0V to 3V Input rise and fall times 10ns Input reference levels 1.5V Over recommended operating conditions unless otherwise specified. PARAMETER MIN (Note 7) TYP (Note 4) MAX (Note 7) UNIT tCl CS to INC Setup 100 ns tlD INC HIGH to U/D Change 100 ns tDI U/D to INC Setup 100 ns tlL INC LOW Period 1 µs tlH INC HIGH Period 1 µs tlC INC Inactive to CS Inactive 1 µs tCPH CS Deselect Time (No Store) 250 ns tCPH CS Deselect Time (Store) 10 ms tCYC INC Cycle Time 2 µs tR , tF (Note 5) INC Input Rise and Fall Time tR VCC (Note 5) VCC Power-up Rate tWR Store Cycle 1.0 5 4 500 µs 50 V/ms 10 ms FN8180.3 February 19, 2008 X93154 AC Timing CS tCYC tCI tIL tIH tIC (STORE) tCPH 90% INC 90% 10% tID tDI tF tR U/D Power-Up and Power-down Requirements There are no restrictions on the power-up or power-down conditions of VCC and the voltages applied to the potentiometer pins provided that VCC is always more positive than or equal to VH and VL, i.e., VCC ≥ VH,VL. The VCC ramp rate specification is always in effect. Pin Descriptions RH and RL The RH and RL pins of the X93154 are equivalent to the fixed terminals of a mechanical potentiometer. The minimum voltage is VSS and the maximum is VCC. The terminology of RH and RL references the relative position of the terminal in relation to wiper movement direction selected by the U/D input. Up/Down (U/D) The U/D input controls the direction of the wiper movement and whether the counter is incremented or decremented. Increment (INC) The INC input is negative-edge triggered. Toggling INC will move the wiper and either increment or decrement the counter in the direction indicated by the logic level on the U/D input. Chip Select (CS) The device is selected when the CS input is LOW. The current counter value is stored in nonvolatile memory when CS is returned HIGH while the INC input is also HIGH. After the store operation is complete the X93154 will be placed in the low power standby mode until the device is selected once again. Pin Names SYMBOL DESCRIPTION RH High terminal RL Low terminal VSS Ground VCC Supply voltage U/D Up/Down control input INC Increment control input CS Chip Select control input Principles of Operation There are three sections of the X93154: the input control, counter and decode section; the nonvolatile memory; and the resistor array. The input control section operates just like an up/down counter. The output of this counter is decoded to turn on a single electronic switch connecting a point on the resistor array to the wiper output. Under the proper conditions the contents of the counter can be stored in nonvolatile memory and retained for future use. The resistor array is comprised of 31 individual resistors connected in series. At either end of the array and between each resistor is an electronic switch that transfers the connection at that point to the wiper. The wiper, when at either fixed terminal, acts like its mechanical equivalent and does not move beyond the last position. That is, the counter does not wrap around when clocked to either extreme. If the wiper is moved several positions, multiple taps are connected to the wiper for tIW (INC to VW change). The 2-terminal resistance value for the device can temporarily change by a significant amount if the wiper is moved several positions. When the device is powered-down, the last wiper position stored will be maintained in the nonvolatile memory. When power is restored, the contents of the memory are recalled and the wiper is set to the value last stored. 5 FN8180.3 February 19, 2008 X93154 Instructions and Programming Mode Selection The INC, U/D and CS inputs control the movement of the wiper along the resistor array. With CS set LOW, the device is selected and enabled to respond to the U/D and INC inputs. HIGH to LOW transitions on INC will increment or decrement (depending on the state of the U/D input) a 5-bit counter. The output of this counter is decoded to select one of thirty two wiper positions along the resistive array. The value of the counter is stored in nonvolatile memory whenever CS transitions HIGH while the INC input is also HIGH. In order to avoid an accidental store during power-up, CS must go HIGH with VCC during initial power-up. When performing multiple write operations, VCC must not decrease by more than 150mV from its initial value. When left open, the CS pin is internally pulled up to VCC by an internal 30k resistor. CS INC U/D L H Wiper Up L L Wiper Down H X Store Wiper Position X X Standby Current L X No Store, Return to Standby L H Wiper Up (not recommended) L L Wiper Down (not recommended) H Symbol Table WAVEFORM The system may select the X93154, move the wiper and deselect the device without having to store the latest wiper position in nonvolatile memory. After the wiper movement is performed as previously described and once the new position is reached, the system must keep INC LOW while taking CS HIGH. The new wiper position will be maintained until changed by the system or until a power-up/down cycle recalled the previously stored data. In order to recall the stored position of the wiper on power-up, the CS pin must be held HIGH. This procedure allows the system to always power-up to a preset value stored in nonvolatile memory; then during system operation minor adjustments could be made. The adjustments might be based on user preference, system parameter changes due to temperature drift, or other system trim requirements. The state of U/D may be changed while CS remains LOW. This allows the host system to enable the device and then move the wiper up and down until the proper trim is attained. MODE INPUTS OUTPUTS Must be steady Will be steady May change from Low to High Will change from Low to High May change from High to Low Will change from High to Low Don’t Care: Changes Allowed Changing: State Not Known N/A Center Line is High Impedance Applications Information Electronic digitally controlled (XDCP) potentiometers provide three powerful application advantages: 1. The variability and reliability of a solid-state potentiometer 2. The flexibility of computer-based digital controls 3. The retentivity of nonvolatile memory used for the storage of multiple potentiometer settings or data . I VR Two terminal variable resistor. Variable current 6 FN8180.3 February 19, 2008 X93154 Low Voltage High Impedance Instrumentation Amplifier 3.3V 10k + + 10k 50k U1A 50k VIN VOUT U1C X93154 (RTOTAL) + 50k - Gain = 10k U1B 10k U1 = LT1467 + - 50k 50k ) ( 1+ 10k RTOTAL 50k Micro-Power LCD Contrast Control 3.3V 300k 240k 3.3V + 100k VOUT = -3.88 ( 1 + 100k U1A - - VOUT = -2.75V TO -11.6V U1B U1 = LMC6042 + 50k 100k 100k ) 50k + RTOTAL -12V X93154 (RTOTAL) Single Supply Variable Gain Amplifier 3.3V 3.3V 20k + 20k U1 VOUT - Gain = 10k U1 = LMC6042 VIN 10k 7 RTOTAL X93154 (RTOTAL) FN8180.3 February 19, 2008 X93154 Thin Dual Flat No-Lead Plastic Package (TDFN) 2X L8.2.5x2 0.15 C A A D 8 LEAD THIN DUAL FLAT NO-LEAD PLASTIC PACKAGE 2X MILLIMETERS 0.15 C B SYMBOL E 6 MIN 0.75 0.80 - A1 - - 0.05 - D2 // 0.10 SIDE VIEW D2 (DATUM B) C 0.08 C A3 7 8 D2/2 1 6 INDEX AREA 0.20 0.25 0.30 5, 8 1.10 7, 8 2.00 BSC 0.90 E E2 A C SEATING PLANE 0.20 REF D B NOTES 0.70 b TOP VIEW MAX A A3 INDEX AREA NOMINAL 1.00 - 2.50 BSC 1.20 e 1.30 1.40 7, 8 0.50 BSC - k 0.20 - - - L 0.30 0.40 0.50 8 N 8 Nd 4 2 3 Rev. 0 8/05 2 NX k NOTES: 1. Dimensioning and tolerancing conform to ASME Y14.5-1994. 2. N is the number of terminals. (DATUM A) 3. Nd refers to the number of terminals on D. E2 4. All dimensions are in millimeters. Angles are in degrees. E2/2 5. Dimension b applies to the metallized terminal and is measured between 0.25mm and 0.30mm from the terminal tip. NX L 6. The configuration of the pin #1 identifier is optional, but must be located within the zone indicated. The pin #1 identifier may be either a mold or mark feature. N N-1 NX b e 8 5 0.10 (Nd-1)Xe REF. M C A B 8. Nominal dimensions are provided to assist with PCB Land Pattern Design efforts, see Intersil Technical Brief TB389. BOTTOM VIEW CL (A1) 7. Dimensions D2 and E2 are for the exposed pads which provide improved electrical and thermal performance. NX (b) L 5 SECTION "C-C" C C TERMINAL TIP e FOR EVEN TERMINAL/SIDE 8 FN8180.3 February 19, 2008 X93154 Mini Small Outline Plastic Packages (MSOP) N M8.118 (JEDEC MO-187AA) 8 LEAD MINI SMALL OUTLINE PLASTIC PACKAGE E1 INCHES E -B- INDEX AREA 1 2 0.20 (0.008) A B C TOP VIEW 4X θ 0.25 (0.010) R1 R GAUGE PLANE A SEATING PLANE -C- A2 A1 b -He D 0.10 (0.004) 4X θ L1 SEATING PLANE C 0.20 (0.008) C a CL E1 C D MAX MIN MAX NOTES 0.037 0.043 0.94 1.10 - A1 0.002 0.006 0.05 0.15 - A2 0.030 0.037 0.75 0.95 - b 0.010 0.014 0.25 0.36 9 c 0.004 0.008 0.09 0.20 - D 0.116 0.120 2.95 3.05 3 E1 0.116 0.120 2.95 3.05 4 0.026 BSC 0.65 BSC - E 0.187 0.199 4.75 5.05 - L 0.016 0.028 0.40 0.70 6 0.037 REF N C 0.20 (0.008) MIN A L1 -A- SIDE VIEW SYMBOL e L MILLIMETERS 0.95 REF 8 R 0.003 R1 0 α - 8 - 0.07 0.003 - 5o 15o 0o 6o 7 - - 0.07 - - 5o 15o - 0o 6o -B- Rev. 2 01/03 END VIEW NOTES: 1. These package dimensions are within allowable dimensions of JEDEC MO-187BA. 2. Dimensioning and tolerancing per ANSI Y14.5M-1994. 3. Dimension “D” does not include mold flash, protrusions or gate burrs and are measured at Datum Plane. Mold flash, protrusion and gate burrs shall not exceed 0.15mm (0.006 inch) per side. 4. Dimension “E1” does not include interlead flash or protrusions and are measured at Datum Plane. - H - Interlead flash and protrusions shall not exceed 0.15mm (0.006 inch) per side. 5. Formed leads shall be planar with respect to one another within 0.10mm (0.004) at seating Plane. 6. “L” is the length of terminal for soldering to a substrate. 7. “N” is the number of terminal positions. 8. Terminal numbers are shown for reference only. 9. Dimension “b” does not include dambar protrusion. Allowable dambar protrusion shall be 0.08mm (0.003 inch) total in excess of “b” dimension at maximum material condition. Minimum space between protrusion and adjacent lead is 0.07mm (0.0027 inch). 10. Datums -A -H- . and - B - to be determined at Datum plane 11. Controlling dimension: MILLIMETER. Converted inch dimensions are for reference only. All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see www.intersil.com 9 FN8180.3 February 19, 2008