NEC Express5800/B120e-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. December 8, 2015 Revision 2.1 NEC Corporation SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 6 Front Views ............................................................................................................................................ 6 CONFIGURATION DIAGRAM ......................................................................................... 6 EXPANSION SLOT .......................................................................................................... 7 SERVER CONFIGURATION ........................................................................................... 8 1 2 3 4 5 6 7 Base Models ................................................................................................................................... 8 2nd Processor ................................................................................................................................ 8 Memory ........................................................................................................................................... 9 3.1 Memory Configuration.......................................................................................................... 9 Internal Drives .............................................................................................................................. 10 4.1 Drive and RAID Configuration ........................................................................................... 10 4.2 Internal Drive Configuration ............................................................................................... 10 I/O Expansion Card ...................................................................................................................... 11 5.1 Network Interface Controller .............................................................................................. 11 5.2 External Storage Controller ............................................................................................... 13 Other Add-in Components .......................................................................................................... 13 6.1 Trusted Platform Module Kit .............................................................................................. 13 6.2 Internal Flash Memory ....................................................................................................... 14 Storage and Tape Blades ............................................................................................................ 14 REFERENCES............................................................................................................... 15 Server Management ............................................................................................................................ 15 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 16 Support Matrix for Adapters and Network Interconnect Devices .................................................. 17 Supported PCI Cards and Installable Slots ...................................................................................... 18 Copyright Notice and Liability Disclaimer ........................................................................................ 19 REVISION HISTORY ..................................................................................................... 20 NEC Corporation Revision 2.1 – December 8, 2015 2 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Technical Specification Key Features High performance with the latest Intel® Xeon® processor E5-2600v2 product family Up to 512 GB of high speed DDR3-1600 memory Full manageability by integrated EXPRESSSCOPE Engine 3 Specification (1/2) Model B120e-h Part Number Processor N8400-220F N8400-219F Intel® Xeon® Intel® Xeon® processor processor E5-2630 v2 E5-2650 v2 2.60 GHz 1 to 2 15 MB 20MB 6C-12T 8C-16T Intel® C602-J Chipset DDR3-1600 ECC Unbuffered Low Power DIMM DDR3-1600 and DDR3-1333 ECC Registered Low Power DIMM 0 GB 512 GB (Sixteen 32 GB) 1 1 ECC, x4 SDDC, Memory Lockstep , Memory Mirror 0 GB SATA SSD: 800 GB ( Two 400GB) SATA : 3Gb/s (Integrated) 2 SATA : RAID 0/1 (Optional ) Not supported 2 [2] Total: 3 slots available 1 Type 1 mezzanine 1 Type 2 mezzanine 1 PCIe for a flexible integrated NIC Integrated in Server Management Controller (32MB) 3 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024 / 16.7M 1 SUV (1 front) EXPRESSSCOPE Engine 3 429 Watt 461 Watt 51.6 x 515.4 x 180.7 mm / 2.0 x 20.3 x 7.1 in 2kg / 5 kg, 4.41 / 13.23 lbs. Blade Enclosure M, Blade Enclosure-H v2 Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE Microsoft® Windows Server® 2008 Standard Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter Type Clock speed Number of Processors Cache Cores and Threads Chipset Memory Internal Storage Expansion Slots Video Type Standard Capacity Maximum Capacity Memory protection Standard Capacity Maximum Capacity Disk Controller RAID Hot Plug Disk Drive Bays [free] Standard Controller (VRAM) Resolution / Color Interfaces Server Management Maximum Power Consumption (VDC) Dimensions (W x D x H ) Weight (Minimum / Maximum) Enclosures Temperature, Relative Humidity (non-condensing) Regulatory and Safety Operating Systems NEC Corporation Revision 2.1 – December 8, 2015 3 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Model B120e-h Operating Systems Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later (x86) 5 Red Hat Enterprise Linux 5.9 or later (EM64T) 5 Red Hat Enterprise Linux 6.4 or later (x86) 5 Red Hat Enterprise Linux 6.4 or later (x86_64) 5 Red Hat Enterprise Linux 7.0 or later VMware ESXi 5.0u2 or later VMware ESXi 5.1u1 or later VMware ESXi 5.5u1 VMware ESXi 6 4 1 To configure memory mirror and memory lockstep configuration, contact your sales representative. 2 Embedded SATA RAID controller is supported only on Windows operating systems. 3 Maximum resolution and color available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ 4 5 For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html (2/2) Model Part Number Processor B120e-h Type Clock speed Number of Processors Cache Cores and Threads Chipset Memory Internal Storage Expansion Slots Video Type Standard Capacity Maximum Capacity Memory protection Standard Capacity Maximum Capacity Disk Controller RAID Hot Plug Disk Drive Bays [free] Standard Controller (VRAM) Resolution / Color Interfaces Server Management Maximum Power Consumption (VDC) Dimensions (W x D x H ) Weight (Minimum / Maximum) NEC Corporation N8400-218F N8400-217F N8400-216F N8400-215F Intel® Xeon® Intel® Xeon® Intel® Xeon® Intel® Xeon® processor processor processor processor E5-2650L v2 E5-2670 v2 E5-2690 v2 E5-2697 v2 1.70 GHz 2.50 GHz 3 GHz 2.70 GHz 1 to 2 25 MB 30 MB 10C-20T 12C-24T Intel® C602-J Chipset DDR3-1600 ECC Unbuffered Low Power DIMM DDR3-1600 and DDR3-1333 ECC Registered Low Power DIMM 0 GB 512 GB (Sixteen 32 GB) 1 1 ECC, x4 SDDC, Memory Lockstep , Memory Mirror 0 GB SATA SSD: 800 GB ( Two 400GB) SATA : 3Gb/s (Integrated) 2 SATA : RAID 0/1 (Optional ) Not supported 2 [2] Total: 3 slots available 1 Type 1 mezzanine 1 Type 2 mezzanine 1 PCIe for a flexible integrated NIC Integrated in Server Management Controller (32MB) 3 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024 / 16.7M 1 SUV (1 front) EXPRESSSCOPE Engine 3 373 Watt 470 Watt 558 Watt 555 Watt 51.6 x 515.4 x 180.7 mm / 2.0 x 20.3 x 7.1 in 2kg / 5 kg, 4.41 / 13.23 lbs. Revision 2.1 – December 8, 2015 4 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Model B120e-h Enclosures Temperature, Relative Humidity (non-condensing) Blade Enclosure M, Blade Enclosure-H v2 Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise (x64) Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise Microsoft® Windows Server® 2012 Standard Microsoft® Windows Server® 2012 Datacenter 4 Microsoft® Windows Server® 2012 R2 Standard 4 Microsoft® Windows Server® 2012 R2 Datacenter 5 Red Hat Enterprise Linux 5.9 or later (EM64T) 5 Red Hat Enterprise Linux 6.4 or later (x86_64) VMware ESXi 5.0u2 or later VMware ESXi 5.1u1 or later VMware ESXi 5.5u1 VMware ESXi 6 Regulatory and Safety Operating Systems 1 2 3 4 5 To configure memory mirror and memory lockstep configuration, contact your sales representative. Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. Maximum resolution and color available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html NEC Corporation Revision 2.1 – December 8, 2015 5 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h External Views Front Views A B K C D E F G H I L J Legend A. B. C. D. E. F. G. H. I. J. K. L. Power LED Power Button System Status LED Dump (NMI) Switch Data LAN 1 Activity LED System Reset Switch Data LAN 2 Activity LED UID LED Button UID LED SUV Connector SSD0 Activity LED SSD1 Activity LED Configuration Diagram CHASSIS FRONT CHASSIS TOP 1 DIMM Slot 4 DIMM Slots 4 DIMM Slots Type II 2.5-inch Drive Cage Processor #2 Processor #1 Type I 4 DIMM Slots Legend: NEC Corporation LAN Slot 4 DIMM Slots Mandatory Components Standard Components Revision 2.1 – December 8, 2015 6 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Expansion Slot #2 #1 #3 Legend #1 #2 #3 NEC Corporation Type-I mezzanine card slot Type-II mezzanine card slot Flexible integrated NIC card slot Revision 2.1 – December 8, 2015 7 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Server Configuration 1 Base Models Product Name / Description Part Number NEC Express5800 B120e-h (6C/E5-2630v2) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2630 v2, EXPRESSBUILDER DVD NEC Express5800 B120e-h (8C/E5-2650v2) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2650 v2, EXPRESSBUILDER DVD NEC Express5800 B120e-h (10C/E5-2650Lv2) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2650L v2, EXPRESSBUILDER DVD NEC Express5800 B120e-h (10C/E5-2670v2) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2670 v2, EXPRESSBUILDER DVD NEC Express5800 B120e-h (10C/E5-2690v2) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2690 v2, EXPRESSBUILDER DVD NEC Express5800 B120e-h (12C/E5-2697v2) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2697 v2, EXPRESSBUILDER DVD N8400-220F N8400-219F N8400-218F N8400-217F N8400-216F N8400-215F NOTE: The base model must be ordered with a memory kit and a network riser card kit. The 32-bit operating systems, Microsoft Windows Server 2008, Red Hat Enterprise Linux 5 (x86) and 6 (x86), are supported only on Xeon E5-2630 v2 and Xeon E5-2650 v2 systems. 2 2nd Processor Available sockets: 1 Product Name / Description Part Number Xeon E5-2630 v2 2nd Processor Kit Intel® Xeon ® Processor E5-2630 v2 (2.60 GHz, 6C/12T, 15 MB) Xeon E5-2650 v2 2nd Processor Kit Intel® Xeon ® Processor E5-2650 v2 (2.60 GHz, 8C/16T, 20 MB) Xeon E5-2650L v2 2nd Processor Kit Intel® Xeon ® Processor E5-2650L v2 (1.70 GHz, 10C/20T, 25 MB) Xeon E5-2670 v2 2nd Processor Kit Intel® Xeon ® Processor E5-2670 v2 (2.50 GHz, 10C/20T, 25 MB) Xeon E5-2690 v2 2nd Processor Kit Intel® Xeon ® Processor E5-2690 v2 (3 GHz, 10C/20T, 25 MB) Xeon E5-2697 v2 2nd Processor Kit Intel® Xeon ® Processor E5-2697 v2 (2.70 GHz, 12C/24T, 30 MB) N8401-077F N8401-076F N8401-075F N8401-074F N8401-073F N8401-072F NOTE: The 2nd processor must be the same with what is used in the base model. NEC Corporation Revision 2.1 – December 8, 2015 8 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h 3 Memory 3.1 Memory Configuration Available slots: 8 per processor Category Product Name / Description Part Number Unbuffered DIMM (UDIMM) Registered DIMM (RDIMM) 4GB DDR3-1600 UNB Memory Kit One 4GB Unbuffered ECC DIMM, DDR3L-1600(PC3L-12800) 4GB DDR3-1600 REG Memory Kit One 4GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 8GB DDR3-1600 REG Memory Kit One 8GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 16GB DDR3-1600 REG Memory Kit One 16GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 32GB DDR3-1333 REG Memory Kit One 32GB Registered ECC DIMM, DDR3L-1333(PC3L-10600) N8402-138F N8402-144F N8402-145F N8402-146F N8402-147F NOTE: Minimum one memory kit per processor must be installed. It is recommended to install four identical memory kits for four channel symmetric memory configurations to increase memory transfer speed. Mix configurations of UDIMM/RDIMM are not supported. At least 5 GB of memory is required for VMware ESXi 5.5 / 6.0. Maximum Memory Speed See the table below for the actual maximum memory transfer speed in Independent Channel / Memory Sparing Configuration. DDR3 memory speed depends on the type of DIMMs, the native memory bus speed of the memory controller and memory configuration. All memory buses operate at the clock frequency of the DIMM with the lowest frequency. Processor Type E5-2630v2 E5-2650v2 E5-2650Lv2 E5-2670v2 E5-2690v2 E5-2697v2 Populated DIMMs UDIMM: 4GB RDIMM: 4 GB, 8 GB, 16 GB RDIMM: 32 GB UDIMM: 4GB RDIMM: 4 GB, 8 GB, 16 GB RDIMM: 32 GB DIMM Speed 1600 MHz 1600 MHz 1066 MHz 1600 MHz 1600 MHz 800 MHz Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. Maximum Memory Size Supported by Operating Systems Microsoft Windows Server 2008 Standard 1 Microsoft Windows Server 2008 Standard (x64) 1 Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2008 Enterprise 1 Microsoft Windows Server 2008 Enterprise (x64) 1 Microsoft Windows Server 2008 R2 Enterprise 1 Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter 1 Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windows Server 2012 R2 Datacenter NEC Corporation Maximum Available Memory 4 GB 32 GB 4 GB 32 GB 64 GB 1 TB 2 TB 4 TB 64 GB 512 GB 512 GB 512 GB Revision 2.1 – December 8, 2015 9 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 Red Hat Enterprise Linux 5 (EM64T) Red Hat Enterprise Linux 6 (x86_64) Red Hat Enterprise Linux 7 2 VMware ESXi 5 2 VMware ESXi 5.5 3 VMware ESXi 6.0 16 GB 16 GB 1 TB 6 TB 512 GB 512 GB 2 TB 4 TB 6 TB 512 GB 512 GB 384 GB 1 The maximum available memory size of Hyper-V systems are below: - Windows Server 2008 Standard (x64) and Windows Server 2008 R2 Standard : 32 GB - Windows Server 2008 Enterprise (x64) and Windows Server 2008 R2 Enterprise : 1TB - Windows Server 2012 / Windows Srever 2012 R2 : 4 TB 2 Up to 1 TB of the main memory is available to each virtual machine. 3 Up to 4 TB of the main memory is available to each virtual machine. 4 Internal Drives 4.1 Drive and RAID Configuration Refer to the section in accordance with your drive configuration. Available Interface Drive-less Two drives Refer to 4.2.1 None Non-RAID Refer to 4.2.2 SATA RAID 0/1 Refer to 4.2.3 SATA NOTE: All drives within a RAID array should be of the same capacity. Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. 4.2 Internal Drive Configuration 4.2.1 Drive-less Category Product Name / Description Part Number Drive Cage Required Drive-less Blade Kit Stiffener N8403-042F 4.2.2 Embedded SATA non-RAID Controller Category Product Name / Description Part Number Drive Cage Required SSD Drive Cage Kit Two 2.5-inch non-hot plug hard drive bays, one internal SATA cable 100GB Non-hot Plug 2.5-inch SATA SSD One 100 GB, 2.5-inch, eMLC, SATA 400GB Non-hot Plug 2.5-inch SATA SSD One 400 GB, 2.5-inch, eMLC, SATA N8403-043F Drive 2 slots available SATA SSD N8450-706 N8450-708 NOTE: Minimum one solid state drive must be installed. NEC Corporation Revision 2.1 – December 8, 2015 10 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h 4.2.3 Embedded SATA RAID Controller Category Product Name / Description Part Number Drive Cage Required SSD Drive Cage Kit Two 2.5-inch non-hot plug hard drive bays, one internal SATA cable 100GB Non-hot Plug 2.5-inch SATA SSD One 100 GB, 2.5-inch, eMLC, SATA 400GB Non-hot Plug 2.5-inch SATA SSD One 400 GB, 2.5-inch, eMLC, SATA N8403-043F Drive 2 slots available SATA SSD N8450-706 N8450-708 NOTE: All drives within a RAID array should be of the same capacity. Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. 5 I/O Expansion Card 5.1 Network Interface Controller Category Riser Adapter Type I Product Name / Description Part Number GbE Dual Port 1GBASE Riser Card Kit N8403-061F 10GbE Dual Port 10GBASE Riser Card Kit N8403-062F Dual Port 10GBASE Riser Card Kit iSCSI boot supported 1000BASE (2ch) Adapter Intel® 82571EB Gigabit Ethernet Adapter Dual Port 1000BASE Adapter Intel® Ethernet Controller I350-AM2 10GBASE-KR LAN interface card Intel® 82599ES 10Gigabit Ethernet Adapter Dual Port 10GBASE Adapter Broadcom BCM57810 Dual Port 10GBASE Adapter Broadcom BCM57810, iSCSI boot supported 1000BASE (4ch) Adapter Intel® 82571EB Gigabit Ethernet Adapter Quad Port 1000BASE Adapter Intel® Ethernet Controller I350-AM4 N8403-064F GbE 10GbE Adapter Type II GbE N8403-021 N8403-076F N8403-035 N8403-065F N8403-067F N8403-022 N8403-077F NOTE: One riser card kit must be installed. Wake on LAN feature is supported only on the riser cards. 8 GB of memory per number of 10GbE network controller is recommended to avoid network performance issues. Up to one 10GbE NIC can be installed when using with 32-bit operating systems. Up to two 10GbE NICs can be installed when using with 64-bit Red Hat Enterprise Linux operating systems. The jumbo frame feature does not support with the Riser Cards Kits on 32-bit Red Hat Enterprise Linux operating systems. The types and number of available NICs when installing 10GBASE Riser Card Kits See the table below for the types and number of available NICs when a Dual Port 10GBASE Riser Card Kit is installed on Windows Server operating systems. NEC Corporation Revision 2.1 – December 8, 2015 11 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h The condition depends on interruption processing resulting from a processor and an operating system and insufficient interruption processing resources may lead to system boot process requiring long time. Processor Type E5-2650v2 E5-2650Lv2 E5-2670v2 E5-2690v2 E5-2697v2 E5-2630v2 Number of Processor Types and Number of Available NICs 1 to 2 All of the NICs can be installed into any slots 2 1 All of the can be installed into any slots Either N8403-065F Dual Port 10GBASE Adapter or N8403-067F Dual Port 10GBASE Adapter can be installed. All of the NICs excluding Dual Port 10GBASE Adapters can be installed into any slots. NIC Teaming feature The server blade supports NIC teaming which is the ability to configure multiple NICs to a single network interface for fault tolerance and load balancing Windows Server 2008 support BASP (Broadcom Advanced Server Program) or Intel PROSet teaming while Windows Server 2012, Windows Server 2012 R2 and Linux support teaming with bonding function supported by OS. When using NIC teaming, please note the following: Any of the network teaming must be processed in a single LAN controller. Teaming feature is not supported on iSCSI interfaces. Bonding feature of Red Hat Enterprise Linux is supported on the following conditions: RHEL 5.9(EM64T) or later, RHEL6.4 or later mode 1 (active-backup), mode 4 (802.3ad) For other modes, contact your sales representative. As for VMware teaming features, load balancing and failover are supported. A teaming in the same controller and a teaming between the standard network and a mezzanin card are possible. Configuring a teaming between different network controllers may cause performance down. NIC Partitioning feature The 10GbE Controllers support NIC partitioning which is the ability to configure a single 10GbE port into four virtual NICs. To use NIC Partitioning, please note the following: NIC Partitioning should be enabled to install Windows Server operating systems, 64-bit Red Hat Enterprise Linux operating systems. NIC Partitioning should be disabled to install 32-bit Red Hat Enterprise Linux operating systems. NIC Partitioning should be configured under the maximum configuration limits for networking when running with VMware systems. For more detail, see the Networking Maximum in the Configuration Maximums document for VMware. VMware system counts each divided network port as nx_nic 10Gb Ethernet port. For connections between virtual machines on the same server, configure the virtual machines on the same virtual switch or disable NIC Partitioning. An external switch may not loopback depending on its function or setting. For connections between controllers, confirm your network specifications in advance. Using iSCSI Storage for Storing User Data See the table below for the support matrix of NIC cards supporting iSCSI, available operating systems, and iSCSI offload feature. NEC Corporation Revision 2.1 – December 8, 2015 12 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Type Part Number Operating Systems iSCSI Offload GbE N8403-061F Windows Server 2008 / Windows Server 2008 R2 / Windows Server 2012 / Windows Server 2012 R2 / Red Hat Enterprise Linux / VMware Windows Server 2008 R2 / Red Hat Enterprise Linux 5 / Red Hat Enterprise Linux 6 / VMware Windows Server 2008 / Windows Server 2008 R2 / Windows Server 2012 / Windows Server 2012 R2 / Red Hat Enterprise Linux 5 / Red Hat Enterprise Linux 6 / VMware Not availble Windows Server 2008 / Windows Server 2008 R2 / Windows Server 2012 / Red Hat Enterprise Linux 5 / Red Hat Enterprise Linux 6 / VMware Windows Server 2008 / Windows Server 2008 R2 / Windows Server 2012 / Windows Server 2012 R2 / Red Hat Enterprise Linux 5 / Red Hat Enterprise Linux 6 / VMware Windows Server 2008 / Windows Server 2008 R2 / Windows Server 2012 / Red Hat Enterprise Linux 5 / Red Hat Enterprise Linux 6 Not availble N8403-021 N8403-022 N8403-076F N8403-077F 10GbE N8403-035 N8403-062F N8403-065F N8403-064F N8403-067F Not availble Not availble Not availble Availble Using iSCSI Boot To configure iSCSI boot system, please contact your sales representatives. 5.2 External Storage Controller 5.2.1 Fibre Channel Controller Category Product Name / Description Part Number Adapter Type I Fibre Channel Controller (8Gbps/2ch) Emulex LightPulse LPe1205-N Host Bus Adapter N8403-034F NOTE: Link speed of two ports in one cards should be identical. One controller can be installed to configure a system booting from SAN with Windows Server 2008. 6 Other Add-in Components 6.1 Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 1.2 module N8415-002F NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this product. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. NEC Corporation Revision 2.1 – December 8, 2015 13 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h 6.2 Internal Flash Memory Product Name / Description Part Number Internal Flash Memory Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without DVD media NOTE: Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the flash memory. The following operations can be performed with the flash memory: - Installation of Windows server with express setup - Installation of Starter Pack—the package of NEC qualified drivers and system setting tools - Installation of NEC ESMPRO Agent and Universal RAID Utility - Performance of the Test and Diagnosis Tool N8415-003F 7 Storage and Tape Blades Category Product Name / Description Part Number Storage NEC Express5800/AD106c 2.5-inch Drive Cage, RAID Controller, Two mezzanine PCI Slots, Two 1000BASE Express5800/AT101b LTO5, Two mezzanine PCI Slots, Two 1000BASE N8404-007F Tape N8404-005F NOTE: For configuring a storage blade, see system configuration guide for storage blades. The Drive-less Blade Kit should be installed to configure a system booting from drives on storage blade. The NIC cards which can be installed on storage and tape blades are the NIC cards which are supported on the server blade. NEC Corporation Revision 2.1 – December 8, 2015 14 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring Boot monitoring Alerting Remote KVM (via LAN) Remote control (via LAN) Others Remote wakeup Centralized management Industry standard 1 2 Temperature, voltage, power, drives, degeneration (memory, hard drive) Hardware event log collection Booting, BIOS/POST stall, OS stall, shutdown HW error, Boot error and OS panic (by SNMP, E-Mail) POST/BIOS setup, DOS utility Panic screen, Boot screen Text-based screen (OS console) GUI-based screen (OS console) Remote reset/power on-off/ dump Power control BIOS and BMC Firmware update 2 BIOS setting OS shutdown Remote media (CD/DVD, FD, USB Key) Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch Scheduling (without UPS) Set automatic IP address via DNS/DHCP Wake On LAN, Wake On Ring Monitoring and control of multiple servers IPMI 2.0 1 1 The feature is not supported on VMware ESXi systems. Some setting items can only be changed. NEC Corporation Revision 2.1 – December 8, 2015 15 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h OS Support Matrix for PCI Cards and Embedded Controllers SSD Drive Cage Kit - Embedded SATA non-RAID controller SSD Drive Cage Kit - Embedded SATA RAID controller Dual Port 1GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Adapter Dual Port 10GBASE Adapter 1000BASE (2ch) Adapter Dual Port 1000BASE Adapter 1000BASE (4ch) Adapter Quad Port 1000BASE Adapter 10GBASE-KR LAN interface card Fibre Channel Controller (8Gbps/2ch) N8403-043F N8403-061F N8403-062F N8403-064F N8403-065F N8403-067F N8403-021 N8403-076F N8403-022 N8403-077F N8403-035 N8403-034F NEC Corporation ESXi 6.0 ESXi 5.0 ESXi 5.1 ESXi 5.5 N8403-043F RHEL 5 x64 RHEL 5 RHEL 6 x64 RHEL 6 RHEL 7 Product Name WS 2008 x64 WS 2008 WS 2008 R2 WS 2012 WS 2012 R2 Part Number - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Revision 2.1 – December 8, 2015 16 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Support Matrix for Adapters and Network Interconnect Devices Network Adapter N8406-035 N8406-036 N8406-051F CardPass-Through 1Gb Card 10Gb Pass-Through 10Gb Intelligent L3 Switch 10Gb Intelligent L3 Switch 1 1 - - - 2 2 2 2 2 N8406-052F N8406-011 N8406-029 1/10Gb Intelligent L3 Switch Dual Port 1GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Adapter Dual Port 10GBASE Adapter 1000BASE (2ch) Adapter Dual Port 1000BASE Adapter 1000BASE (4ch) Adapter Quad Port 1000BASE Adapter 10GBASE-KR LAN interface card N8406-044 N8403-061F N8403-062F N8403-064F N8403-065F N8403-067F N8403-021 N8403-076F N8403-022 N8403-077F N8403-035 1Gb Intelligent L3 Switch Product Name N8460-023 N8460-023A Part Number 1 Existing 1Gb Intelligent L3 Switch installed for embedded NIC can be shared with embedded NIC and the optional NIC if N8406-013 1Gb Inter-link Expansion Card is installed in Blade Enclosure M system 2 N8406-037 10GBASE-SR SFP+ module is not supported Fibre Channel Controller 8G FC switch 2 (24 ports) Fibre Channel Controller (8Gbps/2ch) N8406-042 N8403-034F 8G FC switch (12 ports) 2 Product Name N8406-040 1 Part Number Supported for Blade Enclosure M only Supported for Blade Enclosure H v2 only NEC Corporation Revision 2.1 – December 8, 2015 17 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Supported PCI Cards and Installable Slots Part Number N8403-061F N8403-062F N8403-064F N8403-065F N8403-067F N8403-021 N8403-076F N8403-022 N8403-077F N8403-035 N8403-034F NEC Corporation Product Name Slot # : Slot type: Dual Port 1GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Adapter Dual Port 10GBASE Adapter 1000BASE (2ch) Adapter Dual Port 1000BASE Adapter 1000BASE (4ch) Adapter Quad Port 1000BASE Adapter 10GBASE-KR LAN interface card Fibre Channel Controller (8Gbps/2ch) Slots #1 Type I #2 Type II Revision 2.1 – December 8, 2015 #3 NIC - 18 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 2.1 – December 8, 2015 19 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e-h Revision History Revision Date Description 2.1 December 8, 2015 2.0 June 19, 2015 1.4 October 16, 2014 1.3 August 1, 2014 1.2 July 18, 2014 1.1 January 16, 2014 1.0 September 13, 2013 Others: Supported ESXi versions updated Added notes for NIC Teaming feature and NIC Partitioning feature Others: Added ESXi 6 to the list of operating system supported Update OS support matrix Others: Add Red Hat Enterprise Linux 7 to the list of operating system supported Update OS support matrix Update iSCSI support matrix Others: Add Windows Server 2012 R2 to the list of operating system supported Update OS support matrix Others: Add some notes to configure blade systems Others: Add VMware ESXi 5.5 to the list of operating system supported Update OS support matrix Initial release NEC Corporation Revision 2.1 – December 8, 2015 20