NEC Express5800/B120d-h System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server. January 16, 2014 Revision 5.0 NEC Corporation SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Contents TECHNICAL SPECIFICATION ........................................................................................ 3 Key Features .......................................................................................................................................... 3 Specification .......................................................................................................................................... 3 EXTERNAL VIEWS ......................................................................................................... 5 Front Views ............................................................................................................................................ 5 CONFIGURATION DIAGRAM ......................................................................................... 5 SERVER CONFIGURATION ........................................................................................... 7 1 2 3 4 5 6 Base Models ................................................................................................................................... 7 2nd Processor ................................................................................................................................ 7 Memory ........................................................................................................................................... 8 3.1 Memory Configuration.......................................................................................................... 8 Internal Drives .............................................................................................................................. 10 4.1 Drive and RAID Configuration ........................................................................................... 10 4.2 Internal Drive Configuration ............................................................................................... 10 I/O Expansion Card ...................................................................................................................... 12 5.1 Network Interface Controller .............................................................................................. 12 5.2 External Storage Controller ............................................................................................... 13 Other Add-in Components .......................................................................................................... 13 6.1 Trusted Platform Module Kit .............................................................................................. 14 6.2 Internal Flash Memory ....................................................................................................... 14 REFERENCES............................................................................................................... 15 Server Management ............................................................................................................................ 15 OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 16 Support Matrix for Adapters and Network Interconnect Devices .................................................. 17 Supporting PCI Cards and Installable Slots ..................................................................................... 18 Copyright Notice and Liability Disclaimer ........................................................................................ 19 REVISION HISTORY ..................................................................................................... 20 NEC Corporation Revision 5.0 – January 16, 2014 2 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Technical Specification Key Features High performance with the latest Intel® Xeon® processor E5-2600 product family Up to 512 GB of high speed DDR3-1600 memory Full manageability by integrated EXPRESSSCOPE Engine 3 Specification Model Part Number Processor B120d-h Type Clock speed Number of Processors Cache Cores and Threads Chipset Memory Internal Storage Expansion Slots [free] Video Type Standard Capacity Maximum Capacity Memory protection Standard Capacity Maximum Capacity Disk Controller RAID Hot Plug Disk Drive Bays [free] Standard Controller (VRAM) Resolution / Color Interfaces Server Management Maximum Power Consumption (VDC) Dimensions (W x D x H ) Weight (Minimum / Maximum) Enclosures Temperature, Relative Humidity (non-condensing) Regulatory and Safety Operating Systems NEC Corporation N8400-128F N8400-127F N8100-126F N8400-125F Intel® Xeon® Intel® Xeon® Intel® Xeon® Intel® Xeon® processor processor processor processor E5-2630L E5-2640 E5-2650 E5-2670 2 GHz 2.5 GHz 2 GHz 2.60 GHz 1 to 2 15 MB 20 MB 6C-12T 8C-16T Intel® C602-J Chipset DDR3-1333 ECC Unbuffered Low Power DIMM DDR3-1600 and DDR3-1066 ECC Registered Low Power DIMM 0 GB 512 GB (Sixteen 32 GB) 1 1 ECC, x4 SDDC, Memory Lockstep , Memory Mirror 0 GB SATA SSD: 800 GB ( Two 400GB) SATA : 3Gb/s (Integrated) 2 SATA : RAID 0/1 (Optional ) Not supported 2 [2] Total: 3 slots available 1[1] Type 1 mezzanine 1[1] Type 2 mezzanine 1[1] PCIe for a flexible integrated NIC Integrated in Server Management Controller (32MB) 3 640x480 – 1280x1024 / 16.7M 1 SUV (1 front) EXPRESSSCOPE Engine 3 351 Watt 401 Watt 413 Watt 479 Watt 51.6 x 515.4 x 180.7 mm / 2.0 x 20.3 x 7.1 in 2kg / 5 kg, 4.41 / 13.23 lbs. Blade Enclosure M, Blade Enclosure-H v2 Operating: 10° to 35° C / 50° to 95° F, 20 to 80% Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80% FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE Microsoft® Windows Server® 2003 R2, Standard Edition Microsoft® Windows Server® 2003 R2, Enterprise Edition Microsoft® Windows Server® 2003 R2, Standard x64 Edition Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition Microsoft® Windows Server® 2008 Standard Microsoft® Windows Server® 2008 Enterprise Microsoft® Windows Server® 2008 Standard (x64) Microsoft® Windows Server® 2008 Enterprise (x64) Revision 5.0 – January 16, 2014 3 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Model B120d-h Operating Systems Microsoft® Windows Server® 2008 R2 Standard Microsoft® Windows Server® 2008 R2 Enterprise 4 Microsoft® Windows Server® 2012 Standard 4 Microsoft® Windows Server® 2012 Datacenter 5 Red Hat Enterprise Linux 5.8 or later (x86) 5 Red Hat Enterprise Linux 5.8 or later (EM64T) 5 Red Hat Enterprise Linux 6.2 or later (x86) 5 Red Hat Enterprise Linux 6.2 or later (x86_64) VMware ESX 4.1u2 VMware ESXi 5.0u1 VMware ESXi 5.0u2 VMware ESXi 5.1 VMware ESXi 5.1u1 VMware ESXi 5.5 1 To configure memory mirror and memory lockstep configuration, contact your sales representative. 2 Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. 3 Maximum resolution and color available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors. For Windows Server 2012 installation, download the driver kit from the following website and install it after OS installation http://www.nec.com/en/global/prod/express/download/ 4 5 For Linux support, contact your sales representative or go to the NEC website at: http://www.nec.com/global/prod/express/linux/index.html NEC Corporation Revision 5.0 – January 16, 2014 4 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h External Views Front Views A B K C D E F G H I L J Legend A. B. C. D. E. F. Power LED Power Button System Status LED Dump (NMI) Switch Data LAN 1 Activity LED System Reset Switch NEC Corporation G. H. I. J. K. L. Data LAN 2 Activity LED UID LED Button UID LED SUV Connector SSD0 Activity LED SSD1 Activity LED Revision 5.0 – January 16, 2014 5 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Configuration Diagram CHASSIS FRONT CHASSIS TOP 1 DIMM Slot 4 DIMM Slots 4 DIMM Slots Type II 2.5-inch Drive Cage Processor #2 Processor #1 Type I 4 DIMM Slots Legend: 4 DIMM Slots Mandatory components LAN Slot Standard Components Expansion Slot #2 #1 #3 Legend #1 #2 #3 NEC Corporation Type-I mezzanine card slot Type-II mezzanine card slot Flexible integrated NIC card slot Revision 5.0 – January 16, 2014 6 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Server Configuration 1 Base Models Product Name / Description Part Number NEC Express5800 B120d-h (6C/E5-2630L) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2630L, EXPRESSBUILDER DVD NEC Express5800 B120d-h (6C/E5-2640) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2640, EXPRESSBUILDER DVD NEC Express5800 B120d-h (8C/E5-2650) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2650, EXPRESSBUILDER DVD NEC Express5800 B120d-h (8C/E5-2670) no RAM, no Drive Cage, no Network Controller Including: One Intel Xeon processor E5-2670, EXPRESSBUILDER DVD N8400-128F N8400-127F N8400-126F N8400-125F 2 2nd Processor Available sockets: 1 Product Name / Description Part Number Xeon E5-2630L 2nd Processor Kit Intel® Xeon ® Processor E5-2630L (2 GHz, 6C/12T, 10 MB) Xeon E5-2640 2nd Processor Kit Intel® Xeon ® Processor E5-2640 (2.50 GHz, 6C/12T, 10 MB) Xeon E5-2650 2nd Processor Kit Intel® Xeon ® Processor E5-2650 (2 GHz, 8C/16T, 20 MB) Xeon E5-2670 2nd Processor Kit Intel® Xeon ® Processor E5-2670 (2.60 GHz, 8C/16T, 20 MB) N8401-063F N8401-062F N8401-061F N8401-060F NOTE: The 2nd processor must be the same with what is used in the base model NEC Corporation Revision 5.0 – January 16, 2014 7 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h 3 Memory 3.1 Memory Configuration Available slots: 8 per processor Category Product Name / Description Part Number Unbuffered DIMM (UDIMM) 4GB DDR3-1333 UNB Memory Kit One 4GB Unbuffered ECC DIMM, DDR3L-1333(PC3L-10600) NOTE: The x4 SDDC is not supported. 2GB DDR3-1600 REG Memory Kit One 2GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) NOTE: The x4 SDDC is not supported. 4GB DDR3-1600 REG Memory Kit One 4GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 8GB DDR3-1600 REG Memory Kit One 8GB Registered ECC DIMM, DDR3L-1600(PC3L-12800) 16GB DDR3-1066 REG Memory Kit One 16GB Registered ECC DIMM, DDR3L-1066(PC3L-8500) 32GB DDR3-1066 REG Memory Kit One 32GB Registered ECC DIMM, DDR3L-1066(PC3L-8500) N8402-109F Registered DIMM (RDIMM) N8402-125F N8402-126F N8402-153F N8402-128F N8402-096F NOTE: Minimum one memory kit per processor must be installed. It is recommended to install three identical memory kits for triple-channel symmetric memory configurations to increase memory transfer speed. Mix configurations of UDIMM/RDIMM are not supported. Maximum Memory Speed See the table below for the actual maximum memory transfer speed in Independent Channel / Memory Sparing Configuration. DDR3 memory speed depends on the type of DIMMs, the native memory bus speed of the memory controller and memory configuration. All memory buses operate at the clock frequency of the DIMM with the lowest frequency. Processor Type Memory Power Setting Populated DIMMs DIMM Speed E5-2630L UDIMM: 4GB - 1333 MHz E5-2640 RDIMM: 2 GB, 4 GB, 8 GB, 16 GB RDIMM: 32 GB UDIMM: 4GB RDIMM: 2 GB, 4 GB, 8 GB, 16 GB - 1333 MHz 800 MHz 1333 MHz 1333 MHz 1600 MHz 800 MHz E5-2650 E5-2670 RDIMM: 32 GB NEC Corporation Low (1.35V) Normal (1.5V) - Revision 5.0 – January 16, 2014 8 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Maximum Available Memory See the table below for the maximum memory size that you can actually use on your system. The maximum available memory is less than the maximum physical memory supported by your system because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary depending on the type and the number of PCI cards you are using. Maximum Memory Size Supported by Operating Systems Microsoft Windows Server 2003 R2, Standard Edition Microsoft Windows Server 2008 Standard Microsoft Windows Server 2003 R2, Standard x64 Edition Microsoft Windows Server 2008 Standard (x64) Microsoft Windows Server 2008 R2 Standard Microsoft Windows Server 2003 R2, Enterprise Edition Microsoft Windows Server 2008 Enterprise Microsoft Windows Server 2003 R2, Enterprise x64 Edition Microsoft Windows Server 2008 Enterprise (x64) Microsoft Windows Server 2008 R2 Enterprise Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Red Hat Enterprise Linux 5 Red Hat Enterprise Linux 6 Red Hat Enterprise Linux 5 (EM64T) Red Hat Enterprise Linux 6 (x86_64) 1 VMware ESX 4.1 2 VMware ESXi 5.0 , 5.0 1 2 2 4 GB Maximum Available Memory 32 GB 4 GB (HW-DEP enabled) App. 3.6 GB (HW-DEP disabled) 32 GB 64 GB 64 GB 1 TB 2 TB 512 GB 512 GB 4 TB 512 GB 16 GB 16 GB 1 TB 2 TB 256 GB or 1 TB 2 TB 512 GB 512 GB 256 GB or 512 GB 512 GB Up to 255 GB of the main memory is available to each virtual machine Up to 1 TB of the main memory is available to each virtual machine. NEC Corporation Revision 5.0 – January 16, 2014 9 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h 4 Internal Drives 4.1 Drive and RAID Configuration Refer to the section in accordance with your drive configuration. Available Interface Drive-less Two drives Refer to 4.2.1 None Non-RAID Refer to 4.2.2 SATA RAID 0/1 Refer to 4.2.3 SATA NOTE: Hot plug insertion/removal are not supported in the Embedded SATA configuration. Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. All hard drives within a RAID array should be of the same capacity and rotation speed. Mixing SAS and SATA hard drives in the same system is not supported. 4.2 Internal Drive Configuration 4.2.1 Drive-less Category Product Name / Description Part Number Drive Cage Required Drive-less Blade Kit Stiffener N8403-042F 4.2.2 Embedded SATA non-RAID Controller Category Product Name / Description Part Number Drive Cage Required SSD Drive Cage Kit Two 2.5-inch non-hot plug hard drive bays, one internal SATA cable 100GB Non-hot Plug 2.5-inch SATA SSD One 100 GB, 2.5-inch, eMLC, SATA 400GB Non-hot Plug 2.5-inch SATA SSD One 400 GB, 2.5-inch, eMLC, SATA N8403-043F Drive 2 slots available SATA SSD N8450-706 N8450-708 NOTE: Hot plug insertion/removal is not supported. NEC Corporation Revision 5.0 – January 16, 2014 10 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h 4.2.3 Embedded SATA RAID Controller Category Product Name / Description Part Number Drive Cage Required SSD Drive Cage Kit Two 2.5-inch non-hot plug hard drive bays, one internal SATA cable 100GB Non-hot Plug 2.5-inch SATA SSD One 100 GB, 2.5-inch, eMLC, SATA 400GB Non-hot Plug 2.5-inch SATA SSD One 400 GB, 2.5-inch, eMLC, SATA 100GB Non-hot Plug 2.5-inch SATA SSD One 100 GB, 2.5-inch, eMLC, SATA 400GB Non-hot Plug 2.5-inch SATA SSD One 400 GB, 2.5-inch, eMLC, SATA N8403-043F Drive 2 slots available SATA SSD Drive 2 slots available SATA SSD N8450-706 N8450-708 N8450-706 N8450-708 NOTE: All hard drives within a RAID array should be of the same capacity. Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support Matrix for PCI Cards and Embedded Controllers. NEC Corporation Revision 5.0 – January 16, 2014 11 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h 5 I/O Expansion Card 5.1 Network Interface Controller Category Riser Adapter Type I Product Name / Description Part Number GbE Dual Port 1GBASE Riser Card Kit N8403-061F 10GbE Dual Port 10GBASE Riser Card Kit N8403-062F Dual Port 10GBASE Riser Card Kit iSCSI boot supported 1000BASE (2ch) Adapter Intel® 82571EB Gigabit Ethernet Adapter Dual Port 1000BASE Adapter Intel® Ethernet Controller I350-AM2 10GBASE-KR LAN interface card Intel® 82599ES 10Gigabit Ethernet Adapter NOTE: - Connect to 10Gb Pass-Through Card or N8406-051F 10Gb Intelligent L3 Switch. - NEC Storage connection is not supported with RHEL6. N8403-064F Dual Port 10GBASE Adapter Broadcom BCM57810 Dual Port 10GBASE Adapter Broadcom BCM57810, iSCSI boot supported 10Gb CNA Card 2Ch Dual Port 10Gb Converged Network Adaptor NOTE: - For external FCoE Switch connection, connect via N8406-035/036 10Gb Pass-Through Card. N8403-065F 1000BASE-T(4ch) Adapter Intel® 82571EB Gigabit Ethernet Adapter Quad Port 1000BASE Adapter Intel® Ethernet Controller I350-AM4 N8403-022 GbE 10GbE CNA Adapter Type II GbE N8403-021 N8403-076F N8403-035 N8403-067F N8403-072F N8403-077F NOTE: One riser card kit must be installed. Wake on LAN feature is supported only on the LAN riser cards. The types and number of available NICs when installing 10GBASE Riser Card Kits See the table below for the types and number of available NICs when a Dual Port 10GBASE Riser Card Kit is installed on Windows Server 2008 or Windows Server 2008 R2 or Windows Server 2012. The condition depends on interruption processing resulting from a processor and an operating system and insufficient interruption processing resources may lead to system boot process requiring long time. Processor Type E5-2670 E5-2650 E5-2640 E5-2630L NEC Corporation Number of Processor Types and Number of Available NICs 1 to 2 All of the NICs can be installed into any slots 2 1 All of the can be installed into any slots Either N8403-067F Dual Port 10GBASE Adapter or N8403-067F Dual Port 10BGASE Adapter can be installed. All of the NICs excluding Dual Port 10GBASE Adapters can be installed into any slots. Revision 5.0 – January 16, 2014 12 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h NIC Teaming feature When using NIC teaming, please note the following: Any of the network teaming must be processed in a single LAN controller. Teaming feature is not supported on iSCSI interfaces. To configure NIC bonding, please contact your sales representatives. NIC Partitioning feature N8403-062F/064F 10GBASE riser cards and N8403-065F/067F 10GBASE adapters support NIC partitioning (NPAR.) To use NIC Partitioning, please note the following: NIC Partitioning is supported on Windows Server 2008/2008R2 64bit OS and 64bit Linux OS only. Using iSCSI Boot To configure iSCSI boot system, please contact your sales representatives. 5.2 External Storage Controller 5.2.1 Fibre Channel Controller Category Product Name / Description Part Number Adapter Type I Fibre Channel Controller(4Gbps/2ch) Emulex LightPulse LPe1105-N Host Bus Adapter Fibre Channel Controller(8Gbps/2ch) Emulex LightPulse LPe1205-N Host Bus Adapter N8403-018 N8403-034F NOTE: Link speed of two ports in one cards should be used with the same link speed. NEC Corporation Revision 5.0 – January 16, 2014 13 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h 6 Other Add-in Components 6.1 Trusted Platform Module Kit Product Name / Description Part Number Trusted Platform Module Kit TPM 1.2 module N8415-002F NOTE: The kit is not available in China. The kit is not removable after attachment. "TPM Support" in BIOS setup menu must be activated prior to use of this product. To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker function. The recovery password is required to restore data for hardware replacement during a system error. 6.2 Internal Flash Memory Available socket: 1 Product Name / Description Part Number Internal Flash Memory Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without DVD media NOTE: Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the flash memory. The following operations can be performed with the flash memory: - Installation of Windows server with express setup - Installation of Starter Pack—the package of NEC qualified drivers and system setting tools - Installation of NEC ESMPRO Agent and Universal RAID Utility - Performance of the Test and Diagnosis Tool N8415-003F NEC Corporation Revision 5.0 – January 16, 2014 14 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h References Server Management The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system management features listed in the table below. Standard Hardware monitoring Boot monitoring Alerting Remote KVM (via LAN) Remote control (via LAN) Others Remote wakeup Centralized management Industry standard 1 Temperature, voltage, power, drives, degeneration (memory, hard drive) Hardware event log collection Booting, BIOS/POST stall, OS stall, shutdown HW error, Boot error and OS panic (by SNMP, E-Mail) POST/BIOS setup, DOS utility Panic screen, Boot screen Text-based screen (OS console) GUI-based screen (OS console) Remote reset/power on-off/ dump Power control BIOS and BMC Firmware update 1 BIOS setting OS shutdown Remote media (CD/DVD, FD, USB Key) Server Management Command Line Protocol (DMTF compliant) Remote control via Web browser (without dedicated app) Remote batch Scheduling (without UPS) Set automatic IP address via DNS/DHCP Wake On LAN, Wake On Ring Monitoring and control of multiple servers IPMI 2.0 Some setting items can only be changed. NEC Corporation Revision 5.0 – January 16, 2014 15 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h OS Support Matrix for PCI Cards and Embedded Controllers Product Name N8403-043F SSD Drive Cage Kit - Embedded SATA non-RAID controller SSD Drive Cage Kit - Embedded SATA RAID controller Dual Port 1GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit 1000BASE-T(2ch) adapter Dual Port 1000BASE Adapter 1000BASE-T(4ch) adapter Quad Port 1000BASE Adapter 10GBASE-KR LAN interface card Dual Port 10GBASE Adapter Dual Port 10GBASE Adapter 10Gb CNA Card 2Ch Fibre Channel Controller(4Gbps/2ch) Fibre Channel Controller(8Gbps/2ch) N8403-043F N8403-061 N8403-062 N8403-064 N8403-021 N8403-076F N8403-022 N8403-077F N8403-035 N8403-065F N8403-067F N8403-072F N8403-018 N8403-034 NEC Corporation ESX 4.1 ESXi 5.0 ESXi 5.1 ESXi 5.5 RHEL 5 x64 RHEL 5 RHEL 6 x64 RHEL 6 WS 2003R2 x64 WS 2003R2 WS 2008 x64 WS 2008 WS 2008R2 WS 2012 Part number - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Revision 5.0 – January 16, 2014 16 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Support Matrix for Adapters and Network Interconnect Devices Network Adapter - - 2 2 2 2 2 10Gb Intelligent L3 Switch 10Gb Pass-Through 1 1 - N8406-051F CardPass-Through 1Gb Card N8406-035 N8406-036 N8406-029 1/10Gb Intelligent L3 Switch Dual Port 1GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Adapter Dual Port 10GBASE Adapter 1000BASE-T(2ch) adapter Dual Port 1000BASE Adapter 1000BASE-T(4ch) adapter Quad Port 1000BASE Adapter 10GBASE-KR LAN interface card 10Gb CNA Card 2Ch N8406-044 N8403-061F N8403-062F N8403-064F N8403-065F N8403-067F N8403-021 N8403-076F N8403-022 N8403-077F N8403-035 N8403-072F 1Gb Intelligent L3 Switch Product Name N8460-023 N8460-023A Part number - 1 Existing 1Gb Intelligent L3 Switch installed for embedded NIC can be shared with embedded NIC and the optional NIC if N8406-013 1Gb Inter-link Expansion Card is installed in Blade Enclosure M system 2 N8406-037 10GBASE-SR SFP+ module is not supported Fibre Channel Controller N8406-020 N8406-042 N8406-030 2/4G FC Pass-Through 1 Card (12 port) 4G FC Switch 2 (24port) 8G FC switch 2 (24 ports) 2/4G FC Pass-Through 2 Card (24 port) Fibre Channel Controller(4Gbps/2ch) Fibre Channel Controller(8Gbps/2ch) N8406-021 N8403-018 N8403-034 8G FC switch (12 ports) 2 Product Name N8406-040 1 Part number - - - Supported for Blade Enclosure M only Supported for Blade Enclosure H v2 only NEC Corporation Revision 5.0 – January 16, 2014 17 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Supporting PCI Cards and Installable Slots Part Number N8403-061F N8403-062F N8403-064F N8403-065F N8403-067F N8403-021 N8403-076F N8403-022 N8403-077F N8403-035 N8403-072F N8403-018 N8403-034 NEC Corporation Product Name Slot # : Slot type: Dual Port 1GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Riser Card Kit Dual Port 10GBASE Adapter Dual Port 10GBASE Adapter 1000BASE-T(2ch) adapter 1000BASE(2ch) adapter 1000BASE-T(4ch) adapter 1000BASE(4ch) adapter 10GBASE-KR LAN interface card 10Gb CNA Card 2Ch Fibre Channel Controller(4Gbps/2ch) Fibre Channel Controller(8Gbps/2ch) Slots #1 Type I Revision 5.0 – January 16, 2014 #2 Type II #3 NIC - 18 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less. NEC Corporation Revision 5.0 – January 16, 2014 19 SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120d-h Revision History Revision Date Description 5.0 January 16, 2014 4.0 July 17, 2013 3.0 January 15,2013 2.0 October 26, 2012 1.0 June 26, 2012 New products added: 8GB DDR3-1600 REG Memory Kit / N8402-153F Discontinued products removed: 8GB DDR3-1600 REG Memory Kit / N8402-127F Others: Add VMware ESXi 5.5 to the list of operating system supported Update OS support matrix New products added: 100GB Non-hot Plug 2.5-inch SATA SSD / N8450-706 400GB Non-hot Plug 2.5-inch SATA SSD / N8450-708 Dual Port 1000BASE Adapter / N8403-076F Quad Port 1000BASE Adapter / N8403-077F Discontinued products removed: 100GB Non-hot Plug 2.5-inch SATA SSD / N8450-703 Part number changed: Trusted Platform Module Kit / N8415-002F Others: Add Windows Server 2012 to the list of operating system supported Update OS support matrix VMware ESXi5.1 supported. N8403-065F/067F Dual Port 10GBASE Adapter added. N8403-072F 10Gb CNA Card added. Initial release NEC Corporation Revision 5.0 – January 16, 2014 20