Express5800/B120e配置指南 (中文版)

NEC Express5800/B120e
System Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The guide will
ensure fast and proper configuration of your NEC Express5800 server.
October 16, 2014
Revision 1.3
NEC Corporation
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Contents
TECHNICAL SPECIFICATION ........................................................................................ 3
Key Features .......................................................................................................................................... 3
Specification .......................................................................................................................................... 3
EXTERNAL VIEWS ......................................................................................................... 6
Front Views ............................................................................................................................................ 6
CONFIGURATION DIAGRAM ......................................................................................... 6
EXPANSION SLOT .......................................................................................................... 7
SERVER CONFIGURATION ........................................................................................... 8
1
2
3
4
5
6
7
Base Models ................................................................................................................................... 8
2nd Processor ................................................................................................................................ 8
Memory ........................................................................................................................................... 9
3.1
Memory Configuration.......................................................................................................... 9
Internal Drives .............................................................................................................................. 10
4.1
Drive and RAID Configuration ........................................................................................... 10
4.2
Internal Drive Configuration ............................................................................................... 10
I/O Expansion Card ...................................................................................................................... 12
5.1
Network Interface Controller .............................................................................................. 12
5.2
External Storage Controller ............................................................................................... 14
Other Add-in Components .......................................................................................................... 14
6.1
Trusted Platform Module Kit .............................................................................................. 14
6.2
Internal Flash Memory ....................................................................................................... 14
Storage and Tape Blades ............................................................................................................ 14
REFERENCES............................................................................................................... 16
Server Management ............................................................................................................................ 16
OS Support Matrix for PCI Cards and Embedded Controllers ....................................................... 17
Support Matrix for Adapters and Network Interconnect Devices .................................................. 18
Supporting PCI Cards and Installable Slots ..................................................................................... 19
Copyright Notice and Liability Disclaimer ........................................................................................ 20
REVISION HISTORY ..................................................................................................... 21
NEC Corporation
Revision 1.3 – October 16, 2014
2
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Technical Specification
Key Features



High performance with the latest Intel® Xeon® processor E5-2400 v2 product family
Up to 384 GB of high speed DDR3-1600 memory
Full manageability by integrated EXPRESSSCOPE Engine 3
Specification
(1/2)
Model
B120e
Part Number
N8400-225F
N8400-224F
N8400-223F
Type
Intel® Xeon®
processor E5-2403
v2
Intel® Xeon®
processor
E5-2430L v2
Intel® Xeon®
processor E5-2430
v2
Clock speed
1.80 GHz
2.40 GHz
2.50 GHz
Number of Processors
1 to 2
Cache
10 MB
15 MB
Cores and Threads
4C-4T
6C-12T
Processor
Chipset
Memory
Intel® C602 Chipset
Type
DDR3-1333 ECC Unbuffered Low Power DIMM
DDR3-1600 and DDR3-1066 ECC Registered Low Power DIMM
Standard Capacity
0 GB
Maximum Capacity
384 GB (Twelve 32 GB)
Memory protection
ECC, x4 SDDC, Memory Lockstep , Memory Mirror
Standard Capacity
0 GB
Maximum Capacity
SAS HDD: 2.4 TB (Two 1.2 TB)
SATA HDD: 2 TB (Two 1 TB)
SATA SSD: 800 GB ( Two 400GB)
Disk Controller
SATA : 6Gb/s (Integrated)
SAS: 6Gb/s (Optional)
RAID
SATA : RAID 0/1 (Optional )
SAS : RAID 0/1 (Optional)
Hot Plug
Supported
Disk Drive Bays
2
Expansion Slots
Standard
Total: 3 slots available
1 Type 1 mezzanine
1 Type 2 mezzanine
1 PCIe for a flexible integrated NIC
Video
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
640 x 480, 800 x 600, 1024 x 768, 1280 x 1024 / 16.7M
Internal Storage
1
1
2
Interfaces
1 SUV (1 front)
Server Management
EXPRESSSCOPE Engine 3
Maximum Power Consumption (VDC)
281 Watt
Dimensions (W x D x H )
51.6 x 515.4 x 180.7 mm / 2.0 x 20.3 x 7.1 in
Weight (Minimum / Maximum)
2kg / 5 kg, 4.41 / 13.23 lbs.
Enclosures
Blade Enclosure M, Blade Enclosure-H v2
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 35° C / 50° to 95° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
NEC Corporation
Revision 1.3 – October 16, 2014
335 Watt
3
345 Watt
3
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Model
B120e
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 Standard
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 Standard (x64)
Microsoft® Windows Server® 2008 Enterprise (x64)
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
4
Microsoft® Windows Server® 2012 R2 Standard
4
Microsoft® Windows Server® 2012 R2 Datacenter
5
Red Hat Enterprise Linux 5.9 or later (x86)
5
Red Hat Enterprise Linux 5.9 or later (EM64T)
5
Red Hat Enterprise Linux 6.4 or later (x86)
5
Red Hat Enterprise Linux 6.4 or later (x86_64)
5
Red Hat Enterprise Linux 7.0 or later
VMware ESXi 5.0u2
VMware ESXi 5.1u1
VMware ESXi 5.5u1
1
To configure memory mirror and memory lockstep configuration, contact our sales representative.
2
Embedded SATA RAID controller is supported only on Windows operating systems.
3
Maximum resolution and color available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K
colors.
For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS
installation
http://www.nec.com/en/global/prod/express/download/
4
5
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
(2/2)
Model
B120e
Part Number
Processor
N8400-222F
N8400-221F
Type
Intel® Xeon® processor
E5-2450 v2
Intel® Xeon® processor
E5-2470 v2
Clock speed
2.50 GHz
2.40 GHz
Number of Processors
1 to 2
Cache
20 MB
25 MB
Cores and Threads
8C-16T
10C-20T
Chipset
Memory
Internal Storage
NEC Corporation
Intel® C602 Chipset
Type
DDR3-1333 ECC Unbuffered Low Power DIMM
DDR3-1600 and DDR3-1066 ECC Registered Low Power DIMM
Standard Capacity
0 GB
Maximum Capacity
384 GB (Twelve 32 GB)
Memory protection
ECC, x4 SDDC, Memory Lockstep , Memory Mirror
Standard Capacity
0 GB
Maximum Capacity
SAS HDD: 1.8 TB (Two 900 GB)
SATA HDD: 2 TB (Two 1 TB)
SATA SSD: 200 GB ( Two 100GB)
Disk Controller
SATA : 6Gb/s (Integrated)
SAS: 6Gb/s (Optional)
1
Revision 1.3 – October 16, 2014
1
4
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Model
Internal Storage
(Cont.)
B120e
2
RAID
SATA : RAID 0/1 (Optional )
SAS : RAID 0/1 (Optional)
Hot Plug
Supported
Disk Drive Bays
2
Expansion Slots
Standard
Total: 3 slots available
1 Type 1 mezzanine
1 Type 2 mezzanine
1 PCIe for a flexible integrated NIC
Video
Controller (VRAM)
Integrated in Server Management Controller (32MB)
Resolution / Color
640 x 480, 800 x 600, 1024 x 768, 1280 x 1024 / 16.7M
Interfaces
1 SUV (1 front)
Server Management
EXPRESSSCOPE Engine 3
Maximum Power Consumption (VDC)
425 Watt
Dimensions (W x D x H )
51.6 x 515.4 x 180.7 mm / 2.0 x 20.3 x 7.1 in
Weight (Minimum / Maximum)
2kg / 5 kg, 4.41 / 13.23 lbs.
Enclosures
Blade Enclosure M, Blade Enclosure-H v2
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 35° C / 50° to 95° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, BSMI, CCC, UL, CB, RoHS, WEEE
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 Standard
4
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 Standard (x64)
Microsoft® Windows Server® 2008 Enterprise (x64)
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
4
Microsoft® Windows Server® 2012 R2 Standard
4
Microsoft® Windows Server® 2012 R2 Datacenter
5 6
Red Hat Enterprise Linux 5.9 or later (x86)
6
Red Hat Enterprise Linux 5.9 or later (EM64T)
5 6
Red Hat Enterprise Linux 6.4 or later (x86)
6
Red Hat Enterprise Linux 6.4 or later (x86_64)
5
Red Hat Enterprise Linux 7.0 or later
VMware ESXi 5.0u2
VMware ESXi 5.1u1
VMware ESXi 5.5u1
1
2
3
4
5
6
3
429 Watt
4
To configure memory mirror and memory lockstep configuration, contact your sales representative.
Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS Support
Matrix for PCI Cards and Embedded Controllers.
Maximum resolution and color available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K
colors.
For Windows Server 2012 R2 installation, download the driver kit from the following website and install it after OS
installation
http://www.nec.com/en/global/prod/express/download/
Supports only on Xeon E5-2450 v2 systems.
For Linux support, contact our sales representative or go to the NEC website at:
http://www.nec.com/global/prod/express/linux/index.html
NEC Corporation
Revision 1.3 – October 16, 2014
5
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
External Views
Front Views
A
B
A
B
K
C
D
E
F
G
C
D
E
F
G
0
H
I
H
I
J
J
1
Internal Drive Configuration
Drive-less Configuration
Legend
A.
Power LED
G.
Data LAN 2 Activity LED
B.
Power Button
H.
UID LED Button
C.
System Status LED
I.
UID LED
D.
Dump (NMI) Switch
J.
SUV Connector
E.
Data LAN 1 Activity LED
K.
2.5-inch Drive Bays
F.
System Reset Switch
Configuration Diagram
Two 2.5-inch Drives or
Blank Panel
2.5-inch Drive Cage or
Blank Panel
Legend:
NEC Corporation
6 DIMM
Slots
1 DIMM Slot
6 DIMM Slots
Type II
Processor #1
CHASSIS
TOP
Processor #2
CHASSIS
FRONT
Type I
Mandatory Components
LAN Slot
Standard Components
Revision 1.3 – October 16, 2014
6
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Expansion Slot
#2
#1
#3
Legend
#1
Type-I mezzanine card slot
#2
Type-II mezzanine card slot
#3
Flexible integrated NIC card slot
NOTE:

The type-I mezzanine card slot is available in dual processor configuration.
NEC Corporation
Revision 1.3 – October 16, 2014
7
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Server Configuration
1 Base Models
Product Name / Description
Part Number
NEC Express5800 B120e (4C/E5-2403v2)
no RAM, no Drive Cage, no Network Controller
Including:
One Intel Xeon processor E5-2403 v2, EXPRESSBUILDER DVD
NEC Express5800 B120e (6C/E5-2430Lv2)
no RAM, no Drive Cage, no Network Controller
Including:
One Intel Xeon processor E5-2430L v2, EXPRESSBUILDER DVD
NEC Express5800 B120e (6C/E5-2430v2)
no RAM, no Drive Cage, no Network Controller
Including:
One Intel Xeon processor E5-2430 v2, EXPRESSBUILDER DVD
NEC Express5800 B120e (8C/E5-2450v2)
no RAM, no Drive Cage, no Network Controller
Including:
One Intel Xeon processor E5-2450 v2, EXPRESSBUILDER DVD
NEC Express5800 B120e (10C/E5-2470v2)
no RAM, no Drive Cage, no Network Controller
Including:
One Intel Xeon processor E5-2470 v2, EXPRESSBUILDER DVD
NOTE:
- Not supported with Microsoft Windows Server 2008, Red Hat Enterprise Linux 5 (x86)
and 6 (x86).
N8400-225F
N8400-224F
N8400-223F
N8400-222F
N8400-221F
NOTE:

The base model must be ordered with a memory kit, a drive cage kit and a network riser card kit.
2 2nd Processor
Available sockets: 1
Product Name / Description
Part Number
Xeon E5-2403 v2 2nd Processor Kit
Intel® Xeon ® Processor E5-2403 v2 (1.80 GHz, 4C/4T, 10 MB)
Xeon E5-2430L v2 2nd Processor Kit
Intel® Xeon ® Processor E5-2430L v2 (2.40 GHz, 6C/12T, 15 MB)
Xeon E5-2430 v2 2nd Processor Kit
Intel® Xeon ® Processor E5-2430 v2 (2.50 GHz, 6C/12T, 15 MB)
Xeon E5-2450 v2 2nd Processor Kit
Intel® Xeon ® Processor E5-2450 v2 (2.50 GHz, 8C/16T, 20 MB)
Xeon E5-2470 v2 2nd Processor Kit
Intel® Xeon ® Processor E5-2470 v2 (2.40 GHz, 10C/20T, 25 MB)
N8401-082F
N8401-081F
N8401-080F
N8401-079F
N8401-078F
NOTE:

The 2nd processor must be the same as what is used in the base model.
NEC Corporation
Revision 1.3 – October 16, 2014
8
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
3 Memory
3.1
Memory Configuration
Available slots: 6 per processor
Category
Product Name / Description
Part Number
Unbuffered DIMM
(UDIMM)
Registered DIMM
(RDIMM)
4GB DDR3-1600 UNB Memory Kit
One 4GB Unbuffered ECC DIMM, DDR3L-1600(PC3L-12800)
4GB DDR3-1600 REG Memory Kit
One 4GB Registered ECC DIMM, DDR3L-1600(PC3L-12800)
8GB DDR3-1600 REG Memory Kit
One 8GB Registered ECC DIMM, DDR3L-1600(PC3L-12800)
16GB DDR3-1600 REG Memory Kit
One 16GB Registered ECC DIMM, DDR3L-1600(PC3L-12800)
32GB DDR3-1333 REG Memory Kit
One 32GB Registered ECC DIMM, DDR3L-1333(PC3L-10600)
N8402-141F
N8402-149F
N8402-150F
N8402-151F
N8402-152F
NOTE:




Minimum one memory kit per processor must be installed.
It is recommended to install three identical memory kits for triple-channel symmetric memory
configurations to increase memory transfer speed.
Mix configurations of UDIMM/RDIMM are not supported.
At least 5 GB of memory is required for VMware ESXi 5.5.
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
Maximum Memory Size Supported by Operating Systems
4 GB
4 GB
32 GB
32 GB
64 GB
64 GB
1 TB
384 GB
2 TB
384 GB
Microsoft Windows Server 2012 Standard
1
Microsoft Windows Server 2012 Datacenter
4 TB
384 GB
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 6
16 GB
16 GB
Red Hat Enterprise Linux 5 (EM64T)
1 TB
384 GB
Red Hat Enterprise Linux 6 (x86_64)
Red Hat Enterprise Linux 7
3 TB
384 GB
2 TB
384 GB
4 TB
384 GB
Microsoft Windows Server 2008 Standard
Microsoft Windows Server 2008 Standard (x64)
1
Microsoft Windows Server 2008 R2 Standard
1
Microsoft Windows Server 2008 Enterprise
Microsoft Windows Server 2008 Enterprise (x64)
Microsoft Windows Server 2008 R2 Enterprise
1
VMware ESXi 5
2
VMware ESXi 5.5
1
2
Maximum Available Memory
2
1
1
The maximum available memory size of Hyper-V systems are below:
- Windows Server 2008 Standard (x64) and Windows Server 2008 R2 Standard : 32 GB
- Windows Server 2008 Enterprise (x64) and Windows Server 2008 R2 Enterprise : 1TB
- Windows Server 2012 : 4 TB
Up to 1 TB of the main memory is available to each virtual machine.
NEC Corporation
Revision 1.3 – October 16, 2014
9
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
4 Internal Drives
4.1
Drive and RAID Configuration
Refer to the section in accordance with your drive configuration.
Available Interface
Refer to 4.2.1
None
Refer to 4.2.2
SATA
Embedded SATA
RAID Controller
Refer to 4.2.3
SATA
Optional RAID
Controller
Refer to
SAS, SATA
Drive-less
Two drives
Non-RAID
RAID 0/1
NOTE:

Hot plug insertion/removal are not supported in the Embedded SATA configuration.

Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS
Support Matrix for PCI Cards and Embedded Controllers.

All hard drives within a RAID array should be of the same capacity and rotation speed.

Two drives installed into a system should be identical when optional RAID controller is installed.
4.2
Internal Drive Configuration
4.2.1
Drive-less
Category
Product Name / Description
Part Number
Drive Cage
Required
Drive-less Blade Kit
Blank panel
N8403-056F
4.2.2
Embedded SATA non-RAID Controller
Category
Product Name / Description
Part Number
Drive Cage
Required
Drive
2 slots
available
SATA Drive Cage Kit
Two 2.5-inch hot plug hard drive bays, one internal SATA cable
250GB 7.2K Hot Plug 2.5-inch SATA HDD
One 250 GB, 2.5-inch, SATA2, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
One 500 GB, 2.5-inch, SATA2, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
One 1 TB, 2.5-inch, SATA2, 7,200 rpm
100GB Hot Plug 2.5-inch SATA SSD
One 100 GB, 2.5-inch, eMLC, SATA2
400GB Hot Plug 2.5-inch SATA SSD
One 400 GB, 2.5-inch, eMLC, SATA2
N8403-057F
SATA
HDD
SATA
SSD
N8450-040
N8450-041
N8450-042
N8450-705
N8450-707
NOTE:



Minimum one hard drive or one solid state drive must be installed.
Hot plug insertion/removal is not supported.
Mixing a hard drive and a solid state drive is not supported.
NEC Corporation
Revision 1.3 – October 16, 2014
10
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
4.2.3
Embedded SATA RAID Controller
Category
Product Name / Description
Part Number
Drive Cage
Required
Drive
2 slots
available
SATA Drive Cage Kit
Two 2.5-inch hot plug hard drive bays, one internal SATA cable
250GB 7.2K Hot Plug 2.5-inch SATA HDD
One 250 GB, 2.5-inch, SATA2, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
One 500 GB, 2.5-inch, SATA2, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
One 1 TB, 2.5-inch, SATA2, 7,200 rpm
100GB Hot Plug 2.5-inch SATA SSD
One 100 GB, 2.5-inch, eMLC, SATA2
400GB Hot Plug 2.5-inch SATA SSD
One 400 GB, 2.5-inch, eMLC, SATA2
N8403-057F
SATA
HDD
SATA
SSD
N8450-040
N8450-041
N8450-042
N8450-705
N8450-707
NOTE:



All hard drives within a RAID array should be of the same capacity.
Mixing a hard drive and a solid state drive is not supported.
Embedded SATA RAID controller is supported only on limited OS. For more details, please see OS
Support Matrix for PCI Cards and Embedded Controllers.
4.2.4
RAID 0/1 Controller with 512MB Caches
Category
Product Name / Description
Part Number
Drive Cage
Required
RAID Controller kit (512MB, RAID 0/1)
Two 2.5-inch hot plug hard drive bays, LSI MegaRAID SAS
9267-8i, RAID 0/1, 512 MB
300GB 10K Hot Plug 2.5-inch SAS HDD
One 300 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
600GB 10K Hot Plug 2.5-inch SAS HDD
One 600 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
900GB 10K Hot Plug 2.5-inch SAS HDD
One 900 GB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
1.2TB 10K Hot Plug 2.5-inch SAS HDD
One 1.2TB, 2.5-inch, SAS 6Gb/s, 10,000 rpm
146.5GB 15K Hot Plug 2.5-inch SAS HDD
One 146.5 GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
300GB 15K Hot Plug 2.5-inch SAS HDD
One 300GB, 2.5-inch, SAS 6Gb/s, 15,000 rpm
250GB 7.2K Hot Plug 2.5-inch SATA HDD
One 250 GB, 2.5-inch, SATA2, 7,200 rpm
500GB 7.2K Hot Plug 2.5-inch SATA HDD
One 500 GB, 2.5-inch, SATA2, 7,200 rpm
1TB 7.2K Hot Plug 2.5-inch SATA HDD
One 1 TB, 2.5-inch, SATA2, 7,200 rpm
100GB Hot Plug 2.5-inch SATA SSD
One 100 GB, 2.5-inch, eMLC, SATA2
400GB Hot Plug 2.5-inch SATA SSD
One 400 GB, 2.5-inch, eMLC, SATA2
N8403-059F
Drive
2 Required
SAS
HDD
SATA
HDD
SATA
SSD
N8450-032
N8450-034
N8450-035
N8450-043
N8450-036
N8450-039
N8450-040
N8450-041
N8450-042
N8450-705
N8450-707
NOTE:

Two drives installed into a system should be identical.
NEC Corporation
Revision 1.3 – October 16, 2014
11
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
5 I/O Expansion Card
5.1
Network Interface Controller
Category
Riser
GbE
10GbE
Adapter
Type I
GbE
10GbE
Adapter
Type II
GbE
Product Name / Description
Part Number
Dual Port 1GBASE Riser Card Kit
Qlogic BCM57810
Dual Port 10GBASE Riser Card Kit
Qlogic BCM57810
Dual Port 10GBASE Riser Card Kit
Qlogic BCM57810, iSCSI boot supported
1000BASE (2ch) Adapter
Intel® 82571EB Gigabit Ethernet Adapter
Dual Port 1000BASE Adapter
Intel® Ethernet Controller I350-AM2
10GBASE-KR LAN interface card
Intel® 82599ES 10Gigabit Ethernet Adapter
Dual Port 10GBASE Adapter
Qlogic BCM57810
Dual Port 10GBASE Adapter
Qlogic BCM57810, iSCSI boot supported
1000BASE(4ch) Adapter
Intel® 82571EB Gigabit Ethernet Adapter
Quad Port 1000BASE Adapter
Intel® Ethernet Controller I350-AM4
N8403-061F
N8403-062F
N8403-064F
N8403-021
N8403-076F
N8403-035
N8403-065F
N8403-067F
N8403-022
N8403-077F
NOTE:

One riser card kit must be installed.

Wake on LAN feature is supported only on the riser cards.

8 GB of memory per number of 10GbE network controller is recommended to avoid network
performance issues.

Up to one 10GbE NIC can be installed when using with 32-bit operating systems.

Up to two 10GbE NICs can be installed when using with 64-bit Red Hat Enterprise Linux operating
systems.

The jumbo frame feature does not support with the Riser Cards Kits on 32-bit Red Hat Enterprise
Linux operating systems
The types and number of available NICs when installing 10GBASE Riser Card Kits
See the table below for the types and number of available NICs when a Dual Port 10GBASE Riser Card Kit
is installed on Windows Server operating systems.
The condition depends on interruption processing resulting from a processor and an operating system and
insufficient interruption processing resources may lead to system boot process requiring long time.
Processor
Type
Types and Number of Available NICs
E5-2470 v2
E5-2450 v2
E5-2430 v2
E5-2430L v2
All of the NICs can be installed into any slots
E5-2403 v2
N8403-065F Dual Port 10GBASE Adapter and N8403-067F Dual Port 10GBASE
Adapter can not be installed.
All of the NICs excluding N8403-065F Dual Port 10GBASE Adapter and N8403-067F
Dual Port 10GBASE Adapter can be installed into any slots.
NEC Corporation
Revision 1.3 – October 16, 2014
12
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
NIC Teaming feature
The server blade supports NIC teaming which is the ability to configure multiple NICs to a single network
interface for fault tolerance and load balancing
Windows Server 2008 support BASP (Broadcom Advanced Server Program) or Intel PROSet teaming
while Windows Server 2012, Windows Server 2012 R2 and Linux support teaming with bonding function
supported by OS.
When using NIC teaming, please note the following:


Any of the network teaming must be processed in a single LAN controller.
Teaming feature is not supported on iSCSI interfaces.
NIC Partitioning feature
The 10GbE Controllers support NIC partitioning which is the ability to configure a single 10GbE port into
four virtual NICs. To use NIC Partitioning, please note the following:



NIC Partitioning should be enabled to install Windows Server operating systems, 64-bit Red Hat
Enterprise Linux operating systems.
NIC Partitioning should be disabled to install 32-bit Red Hat Enterprise Linux operating systems.
NIC Partitioning should be configured under the maximum configuration limits for networking when
running with VMware systems. For more detail, see the Networking Maximum in the Configuration
Maximums document for VMware. VMware system counts each divided network port as nx_nic 10Gb
Ethernet port.
Using iSCSI Storage for Storing User Data
See the table below for the support matrix of NIC cards supporting iSCSI, available operating systems, and
iSCSI offload feature.
Type
Part Number
Operating Systems
iSCSI Offload
GbE
N8403-061F
Windows Server 2008 / Windows Server
2008 R2 / Windows Server 2012 / Windows
Server 2012 R2 / Red Hat Enterprise Linux 5
/ Red Hat Enterprise Linux 6 / VMware
Not availble
N8403-021
N8403-022
Windows Server 2008 R2 / Red Hat
Enterprise Linux 5 / Red Hat Enterprise Linux
6 / VMware
Not availble
N8403-076F
N8403-077F
Windows Server 2008 / Windows Server
2008 R2 / Windows Server 2012 / Windows
Server 2012 R2 / Red Hat Enterprise Linux 5
/ Red Hat Enterprise Linux 6 / VMware
Not availble
N8403-035
Windows Server 2008 / Windows Server
2008 R2 / Windows Server 2012 /
Red Hat Enterprise Linux 5 / Red Hat
Enterprise Linux 6 / Vmware
Not availble
N8403-062F
N8403-065F
Windows Server 2008 / Windows Server
2008 R2 / Windows Server 2012 / Windows
Server 2012 R2 / Red Hat Enterprise Linux 5
/ Red Hat Enterprise Linux 6 / VMware
Not availble
N8403-064F
N8403-067F
Windows Server 2008 / Windows Server
2008 R2 / Windows Server 2012 / Red Hat
Enterprise Linux 5 / Red Hat Enterprise Linux
6
Availble
10GbE
Using iSCSI Boot
To configure iSCSI boot system, please contact your sales representatives.
NEC Corporation
Revision 1.3 – October 16, 2014
13
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
5.2
External Storage Controller
5.2.1
Fibre Channel Controller
Category
Product Name / Description
Part Number
Adapter
Type I
Fibre Channel Controller(8Gbps/2ch)
Emulex LightPulse LPe1205-N Host Bus Adapter
N8403-034F
NOTE:

Link speed of two ports in one cards should be identical.

One controller can be installed to configure a system booting from SAN with Windows Server 2008.
6 Other Add-in Components
6.1
Trusted Platform Module Kit
Product Name / Description
Part Number
Trusted Platform Module Kit
TPM 1.2 module
N8415-002F
NOTE:

The kit is not available in China.

The kit is not removable after attachment.

"TPM Support" in BIOS setup menu must be activated prior to use of this product.

To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker
function. The recovery password is required to restore data for hardware replacement during a
system error.
6.2
Internal Flash Memory
Available socket: 1
Product Name / Description
Part Number
Internal Flash Memory
Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without
DVD media
NOTE:
Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the
flash memory.
The following operations can be performed with the flash memory:
- Installation of Windows server with express setup
- Installation of Starter Pack—the package of NEC qualified drivers and system setting
tools
- Installation of NEC ESMPRO Agent and Universal RAID Utility
- Performance of the Test and Diagnosis Tool
N8415-003F
7 Storage and Tape Blades
Category
Product Name / Description
Part Number
Storage
NEC Express5800/AD106c
2.5-inch Drive Cage, RAID Controller, Two mezzanine PCI Slots,
Two 1000BASE
Express5800/AT101b
LTO5, Two mezzanine PCI Slots, Two 1000BASE
N8404-007F
Tape
N8404-005F
NOTE:

For configuring a storage blade, see system configuration guide for storage blades.
NEC Corporation
Revision 1.3 – October 16, 2014
14
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e



The Drive-less Blade Kit should be installed to configure a system booting from drives on storage
blade.
The NIC cards which can be installed on storage and tape blades are the NIC cards which are
supported on the server blade.
The storage blade and tape blade cannot be connected to the server blade that uses Xeon E5-2403
v2 processor and 10GbE network controller.
NEC Corporation
Revision 1.3 – October 16, 2014
15
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
References
Server Management
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.
Standard
Hardware
monitoring
Temperature, voltage, power, drives,
degeneration (memory, hard drive)

Hardware event log collection

Boot monitoring
Booting, BIOS/POST stall, OS stall, shutdown
 
Alerting
HW error, Boot error and OS panic
(by SNMP, E-Mail)

Remote KVM
POST/BIOS setup, DOS utility

(via LAN)
Panic screen, Boot screen
 
Text-based screen (OS console)

GUI-based screen (OS console)

Remote control
Remote reset/power on-off/ dump

(via LAN)
Power control

BIOS and BMC Firmware update

BIOS setting
1
2
2
1
1

OS shutdown

Remote media (CD/DVD, FD, USB Key)

Server Management Command Line Protocol (DMTF
compliant)

Remote control via Web browser
(without dedicated app)

Remote batch

Scheduling (without UPS)

Others
Set automatic IP address via DNS/DHCP

Remote wakeup
Wake On LAN, Wake On Ring

Centralized
management
Industry standard
Monitoring and control of multiple servers

IPMI
2.0
The feature is not supported on VMware ESXi systems.
Some setting items can only be changed.
NEC Corporation
Revision 1.3 – October 16, 2014
16
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
OS Support Matrix for PCI Cards and Embedded Controllers
ESXi 5.0
ESXi 5.1
ESXi 5.5
RHEL 5 x64
RHEL 5
RHEL 6 x64
RHEL 6
RHEL 7
WS 2008 x64
WS 2008
WS 2008 R2
WS 2012
WS 2012 R2
Part number
Product Name
N8403-057F
SATA Drive Cage Kit - Embedded SATA
non-RAID controller

N8403-057F
SATA Drive Cage Kit - Embedded SATA
RAID controller
-
N8403-059F
RAID Controller kit (512MB, RAID 0/1)

N8403-061F
Dual Port 1GBASE Riser Card Kit

N8403-062F
Dual Port 10GBASE Riser Card Kit

N8403-064F
Dual Port 10GBASE Riser Card Kit
-
N8403-065F
Dual Port 10GBASE Adapter
-
N8403-067F
Dual Port 10GBASE Adapter
-
-
N8403-021
1000BASE (2ch) Adapter
-
-
N8403-076F
Dual Port 1000BASE Adapter

N8403-022
1000BASE (4ch) Adapter
-
N8403-077F
Quad Port 1000BASE Adapter

N8403-035
10GBASE-KR LAN interface card
-
N8403-034
Fibre Channel Controller (8Gbps/2ch)
-
NEC Corporation
-
-
-
-
-
-
-
-
-
-
-

-
-
-
-
Revision 1.3 – October 16, 2014
-
-
-
-
-
-
-
-


-
-


17
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Support Matrix for Adapters and Network Interconnect Devices
Network Adapter
N8406-051F
10Gb Intelligent L3
Switch
CardPass-Through
1Gb
Card

10Gb
Pass-Through
1/10Gb Intelligent
L3 Switch

N8406-036
N8406-044
1Gb Intelligent L3
Switch
N8406-029
N8460-023
N8460-023A

Part Number
Product Name
N8403-061F
Dual Port 1GBASE Riser Card Kit

N8403-062F
Dual Port 10GBASE Riser Card Kit





N8403-064F
Dual Port 10GBASE Riser Card Kit





N8403-065F
Dual Port 10GBASE Adapter





N8403-067F
Dual Port 10GBASE Adapter





N8403-021
1000BASE (2ch) Adapter

1
N8403-076F
Dual Port 1000BASE Adapter

1
N8403-022
1000BASE (4ch) Adapter







2


2
-

2


2
-
2

N8403-077F
Quad Port 1000BASE Adapter




N8403-035
10GBASE-KR LAN interface card
-
-
-


1
Existing 1Gb Intelligent L3 Switch installed for embedded NIC can be shared with embedded NIC and the optional
NIC if N8406-013 1Gb Inter-link Expansion Card is installed in Blade Enclosure M system
2
N8406-037 10GBASE-SR SFP+ module is not supported
Fibre Channel Controller
8G FC switch
2
(24 ports)
Fibre Channel Controller (8Gbps/2ch)
N8406-042
N8403-034
8G FC switch
1
(12 ports)
2
Product Name
N8406-040
1
Part Number


Supported for Blade Enclosure M only
Supported for Blade Enclosure H v2 only
NEC Corporation
Revision 1.3 – October 16, 2014
18
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Supporting PCI Cards and Installable Slots
Part Number
Product Name
Slots
Slot # :
#1
#2
#3
Slot type:
Type I
Type II
NIC
N8403-061F
Dual Port 1GBASE Riser Card Kit
-
-

N8403-062F
Dual Port 10GBASE Riser Card Kit
-
-

N8403-064F
Dual Port 10GBASE Riser Card Kit
-
-

N8403-065F
Dual Port 10GBASE Adapter


-
N8403-067F
Dual Port 10GBASE Adapter


-
N8403-021
1000BASE (2ch) Adapter


-
N8403-076F
Dual Port 1000BASE Adapter


-
N8403-022
1000BASE (4ch) Adapter
-

-
N8403-077F
Quad Port 1000BASE Adapter
-

-
N8403-035
10GBASE-KR LAN interface card


-
N8403-034
Fibre Channel Controller (8Gbps/2ch)


-
NOTE:

The type-I mezzanine card slot is available in dual processor configuration.
NEC Corporation
Revision 1.3 – October 16, 2014
19
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
NEC Corporation
Revision 1.3 – October 16, 2014
20
SYSTEM CONFIGURATION GUIDE – NEC Express5800/B120e
Revision History
Revision
Date
Description
1.3
October 16, 2014
Others:
Add Red Hat Enterprise Linux 7 to the list of operating system supported
Update OS support matrix
Update iSCSI support matrix
1.2
August 1, 2014
Others:
Add Windows Server 2012 R2 to the list of operating system supported
Update OS support matrix
1.1
July 18, 2014
Others:
Add some notes to configure blade systems
1.0
January 16, 2014
Initial release
NEC Corporation
Revision 1.3 – October 16, 2014
21