ASTEC LPS254-C

250 Watts
LPS250 Series
Total Power: 250 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs: Single
Electrical Specs
Input
Input range
Frequency
Inrush current
Efficiency
EMI filter
85-264 VAC; 120-300 VDC
47-440 Hz
20 A max., cold start @ 25°C
75% typical at full load
FCC Class B conducted and radiated
CISPR 22 Class B conducted and
radiated EN55022 Class B conducted
and radiated VDE 0878 PT3 Class B
conducted and radiated
0.99 typical
Power factor
Safety ground
leakage current
Special Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Active power factor correction
IEC EN6100-3-2 compliance
Remote sense & remote inhibit
Power fail
Single wire current sharing
Built-in EMI filter
Low output ripple
2 Supervisory outputs 5 V and 12 V
Overvoltage protection
Overload protection
Thermal overload protection
DC power good
Cover -C
120 kHz switching frequency
Optional top with fan cover -CF
Optional end fan cover -CEF
Output
Maximum power
Adjustment range
Supervisory output
Hold-up time
Overload protection
Overvoltage protection
Remote on/off
Operating temperature: 0° to 50°C ambient
derate each output at 2.5% per degree from 50° to
70°C
DC-OK
Electromagnetic susceptibility: Designed to meet
IEC 801, -2, -3, -4, -5, -6, Level 3
Remote sense
Humidity: Operating; non-condensing
5% to 95%
Vibration: Three orthogonal axes, sweep at
1 oct/min, 5 min. dwell at four major resonances
0.7 G peak 5 Hz to 500 Hz, operational
Storage temperature: -40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated: >550,000 hours at full load
and 25°C ambient conditionsation
124
With cover: 250 W with 30 CFM forced
air.
(-C) (-CF) (CEF)
2:1 wide ratio
5 V @ 100 mA regulated; 12V @ 500
mA
20 ms @ 250 W load, 115 VAC nominal
line
at factory voltage setting
Short circuit protection on all outputs.
Case overload protected @ 110-145%
above peak rating
5 V output: 5.7 to 6.7 VDC.
Other models 10% to 25% above
nominal output
Logic Control
Power failure
Environmental
<0.5 mA @ 50/60 Hz, 264 VAC input
TTL logic signal goes high 50-150 msec
after 5 V output. It goes low at least 4
msec before loss of regulation
Requires an external contact (N.O or
N.C) to inhibit outputs
TTL logic goes high 50-150 msec after
the output. It goes low when there is
loss of regulation.
Compensates for 0.5 V lead drop min.
Will operate without remote sense
connected. Reverse connection
protected.
Safety
VDE
UL
CSA
NEMKO
CB
CE
0805/EN60950 (IEC950)
UL1950
CSA 22.2-234 Level 5
EN 60950/EMKO-TUE
(74-sec) 203
Certificate and report
Mark (LVD)
11774-3336-1262
E132002
LR53982C
P95103550
2186
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
rev 04.07.05
AMERICAS
EUROPE
ASIA
5810 Van Allen Way
Carlsbad, CA 92008
Telephone: 760-930-4600
Facsimile: 760-930-0698
Astec House, Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX, UK
Telephone: 44 (1384) 842-211
Facsimile: 44 (1384) 843-355
Units 2111-2116, Level 21
Tower1, Metroplaza
223, Hing Fong Road
Kwai Fong, New Territories
Hong Kong
Telephone: 852-2437-9662
Facsimile: 852-2402-4426
LPS250 Series
Ordering Information
Model
Number
LPS252-C
LPS253-C
LPS254-C
LPS255-C
Output
Voltage
5 V (3-6 V)
12 V (6-12 V)
15 V (12-24 V)
24 V ( 24-48 V)
Minimum
Load
1.50 A
0.63 A
0.50 A
0.32 A
Maximum Load with
30 CFM Forced Air
50 A
21 A
16.7 A
10.4 A
Peak
Load1
60 A
25 A
20 A
12.5 A
Regulation2
±2%
±2%
±2%
±2%
Ripple
P/P (PARD)3
50 mV
120 mV
150 mV
240 mV
Notes:
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 µF in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. If optional CF or CEF fans are not used, 30CFM forced air cooling needs to be provided and is required through
the length of the power supply. Not convection rated.
5. Output voltage adjustment requires a minimum load.
6. Remote inhibit resets OVP latch
Note: -CF suffix added to the model number indicates cover with top fan.
-CEF suffix added to the model number indicates cover with dual end mounted fan cover and AC inlet.
Pin Assignments
6-32 (2 places)
Main Output
Terminal
Block TB1
Connector
SK1
PIN 1
PIN 2
PIN 3
Neutral
Line
Ground
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
+ Remote sense
- Remote sense
Remote inhibit (N.O)
Remote inhibit (N.C)
Common
Current sharing
Power Fail
DC Power Good
SK4
PIN 1
PIN 2
+ Fan’s power source (12 V @ 500 mA)
- Fan’s power source (12 V @ 500 mA)
SK5
PIN 1
PIN 2
+ Supervisory output supply (5 V @ 100 mA)
- Supervisory output supply (5 V @ 100 mA)
PIN 1
PIN 2
+ Fan’s power source (12 V @ 500 mA)
- Fan’s power source (12 V @ 500 mA)
SK3
SK7
Molex 22-01-3027
PINS: 08-50-0114
SK5
Molex 22-01-3027
PINS: 08-50-0114
SK7
Molex 22-01-3027
PINS: 08-50-0114
#6-32 UNC (8 places)
.24 (6.1)
10.0
12345678
SK5
+ve -ve
10.0
SK4
FAN
3.68
(93.6)
SK7
FAN
5.46
(138.6)
6.64
(168.6)
Optional
(-CF)
3.15
Cover
(80)
with Fan
8.52
(216.4)
9.0
(228.6)
10.32
(262.0)
2.17
(55)
10.0
3 2 1
6-32 (3 places)
SK1
Mating Connectors
SK3 Molex 22-01-1084
PINS:08-70-0057
SK4
M3 (4 places)
Output
Voltage
Adjust SK3
Optional
(-CEF)
Cover
with fans
5.0 (127.0)
.55
(14)
1.18 (30.0)
2.0
(50.8)
3.0
(76.2)
1.30
(33.0)
AC Inlet
.79
(20)
3.42 (87.0)
Astec Connector Kit #70-841-005, includes all the above.
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±.02”.
3. Specifications are at factory settings.
4. To enable normally closed remote inhibit, cut
jumper J1.
5. Mounting maximum insertion depth is 0.12”.
6. Warranty: 1 year
7. Weight: 2.6 lb / 1.19 kg
www.astecpower.com