Download Brochure

Alpha Wire Industrial Series
Tray-Rated Cable
Table of Contents
Stationary Tray Cable
Series M Control Cable
4
Stationary or Minimal Flex Applications
Series P Control Cable
6
Highly Flexible Design for Stationary or Minimal Flex Applications
Continuous Flex Cable
Series XM Control Cable
8
Oil-Resistant Cable for Medium-to-High Flex Applications
Series F Flex Tray Cable
12
High-Flex Cable Track Applications
Servomotor/Drive Cable
Series SF Servo Cable
14
Flexible Cable for Servo Applications
Variable Frequency Drive (VFD) Cable
Series V and V-Flex VFD Cable
15
Enhanced Design for Superior Performance in Variable Frequency Drives
Request free samples at www.alphawire.com/sample
2
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Alpha Wire Industrial Series (AWIS)
Advanced Cable Products for Industrial Applications
From the factory floor to process
control, the Alpha Wire Industrial
Series (AWIS) cable line is well
suited to the widest range of
industrial applications. We offer
a variety of cables for general
needs such as control wiring
in both stationary and moving
components. We also offer
application-specific configurations
for use with drives, servo systems,
and factory protocols.
AWIS cables provide
reliable performance
AWIS cables are crafted for
rugged, reliable performance
in your industrial equipment.
They are designed to handle
even your toughest applications,
whether your need is continuous
flexing, superior oil and chemical
resistance, or excellent mechanical
and electrical performance.
Series XM Flexible Control Cable
Tough PVC cable for continuous
flex control applications
Choose the AWIS cable with the
properties you need:
• T
C-ER, PLTC, MTW, and
WTTC ratings
• Oil and chemical resistance
• UV resistance
• Direct burial
• Abrasion resistance
• EMI protection
• High flex cycling
Series M Control Cable
Excellent mechanical and electrical
performance for stationary
cable trays
Series P Enhanced Stationary
Control Cable
Superior oil and chemical
resistance plus easier routing and
installation
Applications
•
•
•
•
•
•
•
•
•
•
Medium-to high-flex equipment
Factory equipment interconnects
Robotics
Machine tools
Automotive assembly equipment
Conveyor systems
Control panels
Transfer shuttles
Solar farms
Automated pick-and-place
systems
• PLC-controlled equipment
• Automated handling systems
• Control/monitoring of speed
and position
Series F Continuous Flex
Control Cables
Rated for up to 20 million rolling
flex cycles
Series SF Servo Control Cable
Maximum flexibility in servo
control and power
Series V VFD Cables
Double-shielded for superior
EMI performance
Series V-Flex VFD Cable
CSA-rated flexible VFD cable
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
3
Series M Control Cable
Oil and Chemical-Resistant PVC Control Cable
for Stationary or Minimal Flex Applications
600 V Unshielded, Multiconductor
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
UL TC-ER
UL MTW
UL WTTC (1000 V)
UL PLTC (300 V)
CSA AWM I/II A/B FT4
CE LVD 2006/95/EC
Operating Temperature
• -25°C to +90°C (static)
• -5°C to +90°C (dynamic)
Conductor Color Coding
• Red, blue, or black insulation*,
numbered
1 green/yellow conductor
1 white-striped neutral
(12 conductors or greater)
Materials
• Finely stranded bare copper
conductors
• PVC/nylon insulation
• Slate PVC jacket
Features
• UL Sunlight Resistant
• UL Oil Res. I
• UL Direct Burial
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
• 90°C Dry/75°C Wet
Availability
Bulk, cut to length
Black Insul.
M18103KW
M18104KW
M18105KW
M18107KW
M18112KW
M18117KW
M18122KW
M18125KW
M18134KW
M18142KW
M18149KW
M18165KW
Blue Insul.
M18103LW
M18104LW
M18105LW
M18107LW
M18112LW
M18117LW
M18122LW
M18125LW
M18134LW
M18142LW
M18149LW
M18165LW
Red Insul.
M18103RW
M18104RW
M18105RW
M18107RW
M18112RW
M18117RW
M18122RW
M18125RW
M18134RW
M18142RW
M18149RW
M18165RW
Conductors
3
4
5
7
12
17
22
25
34
42
49
65
Nominal
Diameter
Inch
mm
0.301
7.65
0.326
8.28
0.353
8.97
0.381
9.68
0.515
13.08
0.594
15.09
0.651
16.54
0.699
17.75
0.777
19.74
0.874
22.20
0.923
23.44
1.029
26.14
Jacket
Thickness
Inch
mm
0.050
1.27
0.050
1.27
0.050
1.27
0.050
1.27
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.085
2.15
0.085
2.15
0.085
2.15
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Black Insul.
M16103KW
M16104KW
M16105KW
M16107KW
M16112KW
M16117KW
M16119KW
M16122KW
M16125KW
M16133KW
M16142KW
M16149KW
M16165KW
Blue Insul.
M16103LW
M16104LW
M16105LW
M16107LW
M16112LW
M16117LW
M16119LW
M16122LW
M16125LW
M16133LW
M16142LW
M16149LW
M16165LW
Red Insul.
M16103RW
M16104RW
M16105RW
M16107RW
M16112RW
M16117RW
M16119RW
M16122RW
M16125RW
M16133RW
M16142RW
M16149RW
M16165RW
Conductors
3
4
5
7
12
17
19
22
25
33
42
49
65
Nominal
Diameter
Inch
mm
0.323
8.20
0.350
8.89
0.380
9.65
0.421
10.69
0.557
14.14
0.644
16.35
0.644
16.35
0.707
17.95
0.761
19.32
0.857
21.76
0.950
24.13
1.005
25.52
1.122
28.49
Jacket
Thickness
Inch
mm
0.050
1.27
0.050
1.27
0.050
1.27
0.055
1.39
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.085
2.15
0.085
2.15
0.085
2.15
0.085
2.15
Series M cable meets the needs for stationary/
cable tray and minimal flexing applications and
where superior resistance to oils and chemicals
is mandatory. It offers superior performance in
static applications, with a tough PVC/PVC-nylon.
FIT® Tubing Recommendations
• FIT-221: General-purpose
cross-linked polyolefin
• FIT-321: Medium-wall, adhesivelined cross-linked polyolefin
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
4
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Series M Control Cable
Oil and Chemical-Resistant PVC Control Cable
for Stationary or Minimal Flex Applications
600 V Unshielded, Multiconductor
14 AWG (2.09 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
UL TC-ER
UL MTW
UL WTTC (1000 V)
UL PLTC (300 V)
CSA AWM I/II A/B FT4
CE LVD 2006/95/EC
Operating Temperature
• -25°C to +90°C (static)
• -5°C to +90°C (dynamic)
Conductor Color Coding
• Red, blue, or black insulation*,
numbered
1 green/yellow conductor
1 white-striped neutral
(12 conductors or greater,
except 14 AWG)
Materials
• Finely stranded bare copper
conductors
• PVC/nylon insulation
• Slate PVC jacket
Features
• UL Sunlight Resistant
• UL Oil Res. I
• UL Direct Burial
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
• 90°C Dry/75°C Wet
Availability
Bulk, cut to length
Black Insul.
M14104KW
M14105KW
M14107KW
M14112KW
M14125KW
Blue Insul.
M14104LW
M14105KW
M14107LW
M14112LW
M14125LW
Red Insul.
M14104RW
M14105RW
M14107RW
M14112RW
M14125RW
Conductors
4
5
7
12
25
Nominal
Diameter
Inch
mm
0.384
9.75
0.428
10.87
0.483
12.26
0.615
15.62
0.887
22.52
Jacket
Thickness
Inch
mm
0.050
1.27
0.055
1.39
0.065
1.65
0.065
1.65
0.085
2.15
12 AWG (3.31 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Black Insul.
M12104KW
M12105KW
M12107KW
Blue Insul.
M12104LW
M12105LW
M12107LW
Red Insul.
M12104RW
M12105RW
M12107RW
Conductors
4
5
7
Nominal
Diameter
Inch
mm
0.44
11.17
0.499
12.67
0.540
13.71
Jacket
Thickness
Inch
mm
0.055
1.39
0.065
1.65
0.065
1.65
10 AWG (5.32 mm2)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.022 (0.56 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Black Insul.
M10104KW
M10105KW
M10107KW
Blue Insul.
M10104LW
M10105LW
M10107LW
Red Insul.
M10104RW
M10105RW
M10107RW
Conductors
4
5
7
Nominal
Diameter
Inch
mm
0.549
13.94
0.600
15.24
0.652
16.56
Jacket
Thickness
Inch
mm
0.065
1.65
0.065
1.65
0.065
1.65
8 AWG (8.52 mm2)
Stranding: 168/30 (168 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm) PVC/0.006 (0.15 mm) nylon
Part No.
Black Insul.
M08104KW
M08105KW
Blue Insul.
M08104LW
M08105LW
Red Insul.
M08104RW
M08105RW
Conductors
4
5
Nominal
Diameter
Inch
mm
0.724
18.38
0.795
20.19
Jacket
Thickness
Inch
mm
0.065
1.65
0.065
1.65
FIT® Tubing Recommendations
• FIT-221: General-purpose
cross-linked polyolefin
• FIT-321: Medium-wall, adhesivelined cross-linked polyolefin
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
5
Series P Enhanced Stationary
Control Cable
Highly Flexible Oil/Chemical-Resistant TPE Control Cable for Minimal
Flex Applications • 600 V Unshielded, Multiconductor
18 AWG (0.96 mm2)
Stranding: 19/30 (19 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.010 mm) nylon
Part No.
UL TC-ER, PLTC
UL TFFN (18 – 16 AWG)
UL THHN (14 – 8 AWG)
CSA AWM I/II A/B FT4
CSA CIC/TC
CE LVD 2006/95/EC
Operating Temperature
• -25°C to +90°C
Voltage Rating
• 600 V (TC-ER)
• 300 V (PLTC)
Conductor Color Coding
• R
ed, blue, or black insulation*,
numbered
1 green/yellow conductor
1 white-striped neutral
(12 conductors or greater)
Materials
• Stranded bare copper conductors
• PVC/nylon insulation
• O
il-resistant thermoplastic
elastomer jacket
Features
• UL Sunlight Resistant
• UL Oil Res. I/II
• 1 0x bend radius, static
and dynamic
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-600: Highly flexible
cross-linked elastomer
• F
IT-650: Chemical/temperatureresistant cross-linked
fluoroelastomer
Black Insul.
MP18103KW
MP18104KW
MP18105KW
MP18107KW
MP18112KW
MP18117KW
MP18122KW
MP18125KW
MP18134KW
MP18142KW
MP18149KW
MP18165KW
Conductors
Blue Insul.
MP18103LW
MP18104LW
MP18105LW
MP18107LW
MP18112LW
MP18117LW
MP18122LW
MP18125LW
MP18134LW
MP18142LW
MP18149LW
MP18165LW
Red Insul.
MP18103RW
MP18104RW
MP18105RW
MP18107RW
MP18112RW
MP18117RW
MP18122RW
MP18125RW
MP18134RW
MP18142RW
MP18149RW
MP18165RW
3
4
5
7
12
17
22
25
34
42
49
65
Nominal
Diameter
Inch
0.313
0.338
0.365
0.393
0.527
0.606
0.663
0.711
0.789
0.886
0.935
1.041
mm
7.95
8.58
9.27
9.98
13.39
15.39
16.84
18.06
20.04
22.50
23.75
26.44
Jacket
Thickness
Inch
0.050
0.050
0.050
0.050
0.065
0.065
0.065
0.065
0.065
0.085
0.085
0.085
mm
1.27
1.27
1.27
1.27
1.65
1.65
1.65
1.65
1.65
2.16
2.16
2.16
16 AWG (1.32 mm2)
Stranding: 26/30 (26 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.010 mm) nylon
Part No.
Black Insul.
MP16103KW
MP16104KW
MP16105KW
MP16107KW
MP16112KW
MP16117KW
MP16122KW
MP16125KW
MP16133KW
MP16142KW
MP16149KW
MP16165KW
Conductors
Blue Insul.
MP16103LW
MP16104LW
MP16105LW
MP16107LW
MP16112LW
MP16117LW
MP16122LW
MP16125LW
MP16133LW
MP16142LW
MP16149LW
MP16165LW
Red Insul.
MP16103RW
MP16104RW
MP16105RW
MP16107RW
MP16112RW
MP16117RW
MP16122RW
MP16125RW
MP16133RW
MP16142RW
MP16149RW
MP16165RW
3
4
5
7
12
17
22
25
33
42
49
65
Nominal
Diameter
Inch
0.335
0.362
0.392
0.423
0.569
0.656
0.719
0.773
0.869
0.962
1.017
1.134
mm
8.51
9.19
9.96
10.74
14.45
16.66
18.26
19.63
22.07
24.43
25.83
28.80
Jacket
Thickness
Inch
0.050
0.050
0.050
0.050
0.065
0.065
0.065
0.065
0.085
0.085
0.085
0.085
mm
1.27
1.27
1.27
1.27
1.65
1.65
1.65
1.65
2.16
2.16
2.16
2.16
Series P cables combine the exceptional oil and
chemical resistance of Series M cable with a
specially formulated thermoplastic elastomer
jacket for additional flexibility, making it easier
to install and route the cable in tight spaces.
The cable can be used in flex applications where
travel distances and flexing speeds are low.
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
6
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Series P Enhanced Stationary
Control Cable
Highly Flexible Oil/Chemical-Resistant TPE Control Cable for Minimal
Flex Applications • 600 V Unshielded, Multiconductor
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.010 mm) nylon
Part No.
UL TC-ER, PLTC
UL TFFN (18 – 16 AWG)
UL THHN (14 – 8 AWG)
CSA AWM I/II A/B FT4
CSA CIC/TC
CE LVD 2006/95/EC
Black Insul.
MP14104KW
MP14105KW
MP14107KW
MP14112KW
MP14125KW
Blue Insul.
MP14104LW
MP14105LW
MP14107LW
MP14112LW
MP14125LW
Conductor Color Coding
• Red, blue, or black insulation*,
numbered
1 green/yellow conductor
1 white-striped neutral
(12 conductors or greater)
Materials
• Stranded bare copper conductors
• PVC/nylon insulation
• Oil-resistant thermoplastic
elastomer jacket
Features
• UL Sunlight Resistant
• UL Oil Res. I/II
• 10x bend radius, static
and dynamic
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-600: Highly flexible
cross-linked elastomer
• FIT-650: Chemical/temperatureresistant cross-linked
fluoroelastomer
Red Insul.
MP14104RW
MP14105RW
MP14107RW
MP14112RW
MP14125RW
4
5
7
12
25
Jacket
Thickness
Nominal
Diameter
Inch
0.396
0.430
0.495
0.627
0.899
mm
10.06
10.92
12.57
15.93
22.83
Inch
0.050
0.050
0.065
0.065
0.085
mm
1.27
1.27
1.65
1.65
2.16
12 AWG (3.31 mm2)
Stranding: 65/30 (65 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.010 mm) nylon
Operating Temperature
• -25°C to +90°C
Voltage Rating
• 600 V (TC-ER)
• 300 V (PLTC)
Conductors
Part No.
Black Insul.
MP12104KW
MP12105KW
MP12107KW
Blue Insul.
MP12104LW
MP12105LW
MP12107LW
Conductors
Red Insul.
MP12104RW
MP12105RW
MP12107RW
4
5
7
Jacket
Thickness
Nominal
Diameter
Inch
0.472
0.511
0.552
mm
11.99
12.98
14.02
Inch
0.065
0.065
0.065
mm
1.65
1.65
1.65
10 AWG (5.32 mm2)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.022 (0.56 mm) PVC/0.005 (0.010 mm) nylon
Part No.
Black Insul.
MP10104KW
MP10105KW
MP10107KW
Blue Insul.
MP10104LW
MP10105LW
MP10107LW
Conductors
Red Insul.
MP10104RW
MP10105RW
MP10107RW
4
5
7
Nominal
Diameter
Inch
0.561
0.612
0.664
mm
14.25
15.54
16.87
Jacket
Thickness
Inch
0.065
0.065
0.065
mm
1.65
1.65
1.65
8 AWG (8.52 mm2)
Stranding: 168/30 (168 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm) PVC/0.005 (0.010 mm) nylon
Part No.
Black Insul.
MP08104KW
MP08105KW
Blue Insul.
MP08104LW
MP08105LW
Conductors
Red Insul.
MP08104RW
MP08105RW
4
5
Nominal
Diameter
Inch
0.736
0.807
mm
18.69
20.50
Jacket
Thickness
Inch
0.065
0.065
mm
1.65
1.65
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
7
Series XM Flexible Control Cable
Tough PVC Cable for High-Flex Cable Track Applications
(12 Million Life Cycles)
600/1000 V Unshielded, PVC/Nylon, PVC
18 AWG (0.83 mm2)
Series XM Flexible Control Cable is the ideal
choice for medium-to-high-flex applications
of up to 12 million cycles. Featuring a
premium-grade PVC jacket, Series XM offers
a durable, oil-resistant construction that
prevents contamination from hazardous
fluids and protects against abrasion. Plus, its
optimum flexibility and performance allows it
to support a variety of industrial applications.
UL TC-ER (600 V)
UL WTTC (1000 V)
UL MTW (600 V)
CSA AWM I/II A/B FT4
CE LVD 2006/95/EC
Operating Temperature
-30°C to +90°C (static)
-5°C to +90°C (dynamic)
Conductor Color Coding
• B
lack, blue, or red* numbered
conductors with one green/
yellow ground conductor
Materials
• S
tranded bare copper
conductors
• PVC/nylon insulation
• Black PVC jacket
Stranding: 41/34 (41 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.13 mm) nylon
Part No.
Nominal Diameter
Jacket Thickness
Conductors
Red
Blue
Black
Inch
mm
Inch
mm
XM1803R XM1803L XM1803K
3
0.308
7.82
0.050
1.27
XM1804R XM1804L XM1804K
4
0.333
8.46
0.050
1.27
XM1805R XM1805L XM1805K
5
0.360
9.14
0.050
1.27
XM1807R XM1807L XM1807K
7
0.418
10.62
0.050
1.27
XM1812R XM1812L XM1812K
12
0.485
12.32
0.050
1.27
XM1817R XM1817L XM1817K
17
0.597
15.16
0.065
1.65
XM1822R XM1822L XM1822K
22
0.656
16.66
0.065
1.65
XM1825R XM1825L XM1825K
25
0.717
18.21
0.065
1.65
XM1834R XM1834L XM1834K
34
0.775
19.69
0.065
1.65
XM1842R XM1842L XM1842K
42
0.874
22.20
0.085
2.16
XM1849R XM1849L XM1849K
49
0.965
24.51
0.085
2.16
XM1865R XM1865L XM1865K
65
1.052
26.72
0.085
2.16
16 AWG (1.31 mm2)
Stranding: 65/34 (65 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.13 mm) nylon
Part No.
Nominal Diameter
Jacket Thickness
Conductors
Red
Blue
Black
Inch
mm
Inch
mm
XM1603R XM1603L XM1603K
3
0.334
8.48
0.050
1.27
XM1604R XM1604L XM1604K
4
0.362
9.19
0.050
1.27
XM1605R XM1605L XM1605K
5
0.393
9.98
0.050
1.27
XM1607R XM1607L XM1607K
7
0.459
11.66
0.050
1.27
XM1612R XM1612L XM1612K
12
0.565
14.35
0.065
1.65
XM1617R XM1617L XM1617K
17
0.657
16.69
0.065
1.65
XM1619R XM1619L XM1619K
19
0.691
17.55
0.065
1.65
XM1622R XM1622L XM1622K
22
0.724
18.39
0.065
1.65
XM1625R XM1625L XM1625K
25
0.793
20.14
0.065
1.65
XM1633R XM1633L XM1633K
33
0.899
22.83
0.085
2.16
XM1642R XM1642L XM1642K
42
0.966
24.54
0.085
2.16
XM1649R XM1649L XM1649K
49
1.069
27.15
0.085
2.16
XM1665R XM1665L XM1665K
65
1.168
29.67
0.085
2.16
Features
• UL Oil Res. I
• UL Sunlight Resistant
• Suitable for NFPA 79 application
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-600: Highly flexible
cross-linked elastomer
• FIT-650: Chemical- and
temperature-resistant
fluoroelastomer
8
14 AWG (2.11 mm2)
Red
XM1403R
XM1404R
XM1405R
XM1407R
XM1412R
Stranding: 105/34 (105 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.13 mm) nylon
Part No.
Nominal Diameter
Jacket Thickness
Conductors
Blue
Black
Inch
mm
Inch
mm
XM1403L XM1403K
3
0.366
9.30
0.050
1.27
XM1404L XM1404K
4
0.398
10.11
0.050
1.27
XM1405L XM1405K
5
0.464
11.79
0.065
1.65
XM1407L XM1407K
7
0.539
13.69
0.065
1.65
XM1412L XM1412K
12
0.627
15.93
0.065
1.65
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Series XM Flexible Control Cable
Tough PVC Cable for High-Flex Cable Track Applications
(12 Million Life Cycles)
600/1000 V Unshielded, PVC/Nylon, PVC
12 AWG (3.38 mm2)
UL TC-ER (600 V)
UL WTTC (1000 V)
UL MTW (600 V)
CSA AWM I/II A/B FT4
CE LVD 2006/95/EC
Operating Temperature
-30°C to +90°C (static)
-5°C to +90°C (dynamic)
Conductor Color Coding
• B
lack, blue, or red* numbered
conductors with one green/
yellow ground conductor
Materials
• S
tranded bare copper
conductors
• PVC/nylon insulation
• Black PVC jacket
Red
XM1203R
XM1204R
XM1205R
XM1207R
Stranding 168/34 (168 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.13 mm) nylon
Part No.
Nominal Diameter
Jacket Thickness
Conductors
Blue
Black
Inch
mm
Inch
mm
XM1203L XM1203K
3
0.431
10.95
0.050
1.27
XM1204L XM1204K
4
0.501
12.73
0.065
1.65
XM1205L XM1205K
5
0.545
13.84
0.065
1.65
XM1207L XM1207K
7
0.640
16.26
0.065
1.65
10 AWG (5.32 mm2)
Red
XM1003R
XM1004R
XM1005R
XM1007R
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.022 (0.56 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Nominal Diameter
Jacket Thickness
Conductors
Blue
Black
Inch
mm
Inch
mm
XM1003L XM1003K
3
0.487
12.37
0.050
1.27
XM1004L XM1004K
4
0.565
14.35
0.065
1.65
XM1005L XM1005K
5
0.618
15.70
0.065
1.65
XM1007L XM1007K
7
0.729
18.52
0.065
1.65
8 AWG (8.51 mm2)
Stranding: 168/30 (168 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm) PVC/0.006 (0.15 mm) nylon
Part No.
Nominal Diameter
Jacket Thickness
Conductors
Red
Blue
Black
Inch
mm
Inch
mm
XM0803R XM0803L XM0803K
3
0.671
17.04
0.065
1.65
XM0804R XM0804L XM0804K
4
0.737
18.72
0.065
1.65
Features
• UL Oil Res. I
• UL Sunlight Resistant
• Suitable for NFPA 79 application
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-600: Highly flexible
cross-linked elastomer
• FIT-650: Chemical- and
temperature-resistant
fluoroelastomer
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
9
Series XM Flexible Control Cable
Tough PVC Cable for High-Flex Cable Track Applications
(12 Million Life Cycles)
600/1000 V Braid Shielded, PVC/Nylon, PVC
18 AWG (0.83 mm2)
UL TC-ER (600 V)
UL WTTC (1000 V)
UL MTW (600 V)
CSA AWM I/II A/B FT4
CE LVD 2006/95/EC
Operating Temperature
-30°C to +90°C (static)
-5°C to +90°C (dynamic)
Red
XM1803RCY
XM1804RCY
XM1805RCY
XM1807RCY
XM1812RCY
XM1817RCY
XM1822RCY
XM1825RCY
XM1834RCY
XM1842RCY
XM1849RCY
Conductor Color Coding
16 AWG (1.31 mm2)
• B
lack, blue, or red* numbered
conductors with one green/
yellow ground conductor
Materials
• S
tranded bare copper
conductors
• PVC/nylon insulation
• T
inned copper braid shield,
85% coverage
• Black PVC jacket
Features
• UL Oil Res. I
• UL Sunlight Resistant
• Suitable for NFPA 79 application
Stranding: 41/34 (41 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.13 mm) nylon
Jacket
Nominal
Part No.
Diameter
Thickness
Conductors
Blue
Black
Inch
mm
Inch
mm
XM1803LCY XM1803KCY
3
0.336
8.53
0.050
1.27
XM1804LCY XM1804KCY
4
0.361
9.17
0.050
1.27
XM1805LCY XM1805KCY
5
0.388
9.86
0.050
1.27
XM1807LCY XM1807KCY
7
0.446
11.33
0.050
1.27
XM1812LCY XM1812KCY
12
0.549
13.94
0.050
1.27
XM1817LCY XM1817KCY
17
0.631
16.03
0.065
1.65
XM1822LCY XM1822KCY
22
0.697
17.70
0.065
1.65
XM1825LCY XM1825KCY
25
0.758
19.25
0.065
1.65
XM1834LCY XM1834KCY
34
0.856
21.74
0.065
1.65
XM1842LCY XM1842KCY
42
0.915
23.24
0.085
2.16
XM1849LCY XM1849KCY
49
1.006
25.55
0.085
2.16
Red
XM1603RCY
XM1604RCY
XM1605RCY
XM1607RCY
XM1612RCY
XM1617RCY
XM1619RCY
XM1622RCY
XM1625RCY
XM1633RCY
XM1642RCY
XM1649RCY
Availability
Stranding: 65/34 (65 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.13 mm) nylon
Jacket
Nominal
Part No.
Diameter
Thickness
Conductors
Blue
Black
Inch
mm
Inch
mm
XM1603LCY XM1603KCY
3
0.362
9.19
0.050
1.27
XM1604LCY XM1604KCY
4
0.390
9.91
0.050
1.27
XM1605LCY XM1605KCY
5
0.421
10.69
0.050
1.27
XM1607LCY XM1607KCY
7
0.517
13.13
0.050
1.27
XM1612LCY XM1612KCY
12
0.599
15.21
0.065
1.65
XM1617LCY XM1617KCY
17
0.698
17.73
0.065
1.65
XM1619LCY XM1619KCY
19
0.732
18.59
0.065
1.65
XM1622LCY XM1622KCY
22
0.765
19.43
0.065
1.65
XM1625LCY XM1625KCY
25
0.874
22.20
0.065
1.65
XM1633LCY XM1633KCY
33
0.940
23.88
0.085
2.16
XM1642LCY XM1642KCY
42
1.007
25.58
0.085
2.16
XM1649LCY XM1649KCY
49
1.110
28.19
0.085
2.16
14 AWG (2.11 mm2)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-600: Highly flexible
cross-linked elastomer
• FIT-650:
Chemical- and
temperature-resistant
fluoroelastomer
Red
XM1403RCY
XM1404RCY
XM1405RCY
XM1407RCY
XM1412RCY
Stranding: 105/34 (105 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.13 mm) nylon
Jacket
Nominal
Part No.
Diameter
Thickness
Conductors
Blue
Black
Inch
mm
Inch
mm
XM1403LCY XM1403KCY
3
0.394
10.01 0.050
1.27
XM1404LCY XM1404KCY
4
0.426
10.82 0.050
1.27
XM1405LCY XM1405KCY
5
0.492
12.50 0.065
1.65
XM1407LCY XM1407KCY
7
0.573
14.55 0.065
1.65
XM1412LCY
XM1412KCY
12
0.661
16.79 0.065
1.65
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
10
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Series XM Flexible Control Cable
Tough PVC Cable for High-Flex Cable Track Applications
(12 Million Life Cycles)
600/1000 V Braid Shielded, PVC/Nylon, PVC
12 AWG (3.38 mm2)
UL TC-ER (600 V)
UL WTTC (1000 V)
UL MTW (600 V)
CSA AWM I/II A/B FT4
CE LVD 2006/95/EC
Red
XM1203RCY
XM1204RCY
XM1205RCY
XM1207RCY
10 AWG (5.32 mm2)
Operating Temperature
-30°C to +90°C (static)
-5°C to +90°C (dynamic)
Conductor Color Coding
• B
lack, blue, or red* numbered
conductors with one green/
yellow ground conductor
Materials
• S
tranded bare copper
conductors
• PVC/nylon insulation
• Tinned copper braid shield,
85% coverage
• Black PVC jacket
Stranding 168/34 (168 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.13 mm) nylon
Jacket
Nominal
Part No.
Diameter
Thickness
Conductors
Blue
Black
Inch
mm
Inch
mm
XM1203LCY XM1203KCY
3
0.459
11.66
0.050
1.27
XM1204LCY XM1204KCY
4
0.529
13.44 0.065
1.65
XM1205LCY XM1205KCY
5
0.579
14.71
0.065
1.65
XM1207LCY XM1207KCY
7
0.674
17.12
0.065
1.65
Red
XM1003RCY
XM1004RCY
XM1005RCY
XM1007RCY
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.022 (0.56 mm) PVC/0.005 (0.13 mm) nylon
Jacket
Nominal
Part No.
Diameter
Thickness
Conductors
Blue
Black
Inch
mm
Inch
mm
XM1003LCY XM1003KCY
3
0.551
14.00 0.050
1.27
XM1004LCY XM1004KCY
4
0.599
15.21
0.065
1.65
XM1005LCY XM1005KCY
5
0.652
16.56
0.065
1.65
XM1007LCY XM1007KCY
7
0.770
19.56
0.065
1.65
8 AWG (8.51 mm2)
Stranding: 168/30 (168 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm) PVC/0.006 (0.15 mm) nylon
Jacket
Nominal
Part No.
Diameter
Thickness
Conductors
Red
Blue
Black
Inch
mm
Inch
mm
XM0803RCY XM0803LCY XM0803KCY
3
0.712
18.08 0.065
1.65
XM0804RCY XM0804LCY XM0804KCY
4
0.778
19.76
0.065
1.65
Features
• UL Oil Res. I
• UL Sunlight Resistant
• Suitable for NFPA 79 application
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-600: Highly flexible
cross-linked elastomer
• FIT-650: Chemical- and
temperature-resistant
fluoroelastomer
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
11
Series F Continuous Flex Control Cable
Continuous Flex TPE Control Cable
(20 Million Flex Life Cycles)
600 V Unshielded, Multiconductor
18 AWG (0.83 mm2)
Stranding: 41/34 (41 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
UL TC-ER, PLTC
UL TFFN (18 – 16 AWG)
UL THHN (14 – 8 AWG)
CSA AWM I/II A/B FT4
CSA CIC/TC
CE LVD 2006/95/EC
Operating Temperature
• -25°C to +90°C (static)
• -5°C to +90°C (dynamic)
Conductor Color Coding
• R
ed, blue, or black insulation*,
numbered
1 green/yellow conductor
1 white-striped neutral
(12 conductors or greater)
Materials
• S
tranded bare copper
conductors
• PVC/nylon insulation
• B
lack oil-resistant thermoplastic
elastomer jacket
Features
• UL Sunlight Resistant
• UL Oil Res. I/II
• 10x bend radius
• Over 20 million rolling flex cycles
• Tic-tock and twist test per
MIL-C-13777G
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-600: Highly flexible,
cross-linked elastomer
• FIT-650: Chemical- and
temperature-resistant
fluoroelastomer
12
Black Insul.
F18003KW
F18004KW
F18005KW
F18007KW
F18012KW
F18017KW
F18022KW
F18025KW
F18034KW
F18042KW
F18049KW
F18065KW
Blue Insul.
F18003LW
F18004LW
F18005LW
F18007LW
F18012LW
F18017LW
F18022LW
F18025LW
F18034LW
F18042LW
F18049LW
F18065LW
Red Insul.
F18003RW
F18004RW
F18005RW
F18007RW
F18012RW
F18017RW
F18022RW
F18025RW
F18034RW
F18042RW
F18049RW
F18065RW
Conductors
3
4
5
7
12
17
22
25
34
42
49
65
Nominal
Diameter
Inch
mm
0.308
7.82
0.333
8.46
0.360
9.14
0.418
10.62
0.515
13.08
0.597
15.16
0.656
16.66
0.717
18.21
0.775
19.69
0.874
22.20
0.965
24.51
1.052
26.72
Jacket
Thickness
Inch
mm
0.050
1.27
0.050
1.27
0.050
1.27
0.050
1.27
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.085
2.16
0.085
2.16
0.085
2.16
16 AWG (1.31 mm2)
Stranding: 65/34 (65 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Black Insul.
F16003KW
F16004KW
F16005KW
F16007KW
F16012KW
F16017KW
F16019KW
F16022KW
F16025KW
F16033KW
F16042KW
F16049KW
F16065KW
Blue Insul.
F16003LW
F16004LW
F16005LW
F16007LW
F16012LW
F16017LW
F16019LW
F16022LW
F16025LW
F16033LW
F16042LW
F16049LW
F16065LW
Red Insul.
F16003RW
F16004RW
F16005RW
F16007RW
F16012RW
F16017RW
F16019RW
F16022RW
F16025RW
F16033RW
F16042RW
F16049RW
F16065RW
Conductors
3
4
5
7
12
17
19
22
25
33
42
49
65
Nominal
Diameter
Inch
mm
0.334
8.48
0.362
9.19
0.393
9.98
0.489
12.42
0.565
14.35
0.657
16.69
0.691
17.55
0.724
18.39
0.793
20.14
0.899
22.83
0.966 24.54
1.069
27.15
1.168
29.67
Jacket
Thickness
Inch
mm
0.050
1.27
0.050
1.27
0.050
1.27
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.085
2.16
0.085
2.16
0.085
2.16
0.085
2.16
Designed for a variety of flexing styles,
Series F cables have been tested to exceed
over 20 million rolling flex cycles, making
them ideal for both single-axis and multi-axis
motion control and robotic applications where
continuous flexing is required. The TPE jacket
offers exceptional resistance to oils, solvents,
and chemicals found in industrial applications.
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Series F Continuous Flex Control Cable
Continuous Flex TPE Control Cable
(20 Million Flex Life Cycles)
600 V Unshielded, Multiconductor
14 AWG (2.11 mm2)
Stranding: 105/34 (105 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
UL TC-ER, PLTC
UL TFFN (18 – 16 AWG)
UL THHN (14 – 8 AWG)
CSA AWM I/II A/B FT4
CSA CIC/TC
CE LVD 2006/95/EC
Operating Temperature
• -25°C to +90°C (static)
• -5°C to +90°C (dynamic)
Conductor Color Coding
• Red, blue, or black insulation*,
numbered
1 green/yellow conductor
1 white-striped neutral
(12 conductors or greater,
except 14 AWG)
Materials
• Stranded bare copper
conductors
• PVC/nylon insulation
• Black oil-resistant thermoplastic
elastomer jacket
Features
• UL Sunlight Resistant
• UL Oil Res. I/II
• 10x bend radius
• Over 20 million rolling flex cycles
• Tic-tock and twist test per
MIL-C-13777G
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Black Insul.
F14004KW
F14005KW
F14007KW
F14012KW
Blue Insul.
F14004LW
F14005LW
F14007LW
F14012LW
Red Insul.
F14004RW
F14005RW
F14007RW
F14012RW
Conductors
4
5
7
12
Nominal
Diameter
Inch
mm
0.398
10.11
0.434
11.02
0.539
13.69
0.628
15.95
Jacket
Thickness
Inch
mm
0.050
1.27
0.050
1.27
0.065
1.65
0.065
1.65
12 AWG (3.38 mm2)
Stranding: 168/34 (168 x 0.16 mm)
Insulation thickness: 0.016 (0.41 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Black Insul.
F12004KW
F12005KW
F12007KW
Blue Insul.
F12004LW
F12005LW
F12007LW
Red Insul.
F12004RW
F12005RW
F12007RW
Conductors
4
5
7
Nominal
Diameter
Inch
mm
0.501
12.73
0.545 13.84
0.640 16.26
Jacket
Thickness
Inch
mm
0.065
1.65
0.065
1.65
0.065
1.65
10 AWG (5.32 mm2)
Stranding: 105/30 (105 x 0.25 mm)
Insulation thickness: 0.022 (0.56 mm) PVC/0.005 (0.10 mm) nylon
Part No.
Black Insul.
F10004KW
F10005KW
F10007KW
Blue Insul.
F10004LW
F10005LW
F10007LW
Red Insul.
F10004RW
F10005RW
F10007RW
Conductors
4
5
7
Nominal
Diameter
Inch
mm
0.565
14.35
0.618
15.70
0.729
18.52
Jacket
Thickness
Inch
mm
0.065
1.65
0.065
1.65
0.065
1.65
8 AWG (8.51 mm2)
Stranding: 168/30 (168 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm) PVC/0.006 (0.15 mm) nylon
Part No.
Black Insul.
F08004KW
Blue Insul.
F08004LW
Red Insul.
F08004RW
Conductors
4
Nominal
Diameter
Inch
mm
0.740 18.80
Jacket
Thickness
Inch
mm
0.065
1.65
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-600: Highly flexible,
cross-linked elastomer
• FIT-650: Chemical- and
temperature-resistant
fluoroelastomer
*Red insulation: AC circuits operating at less than line voltage
Blue insulation: DC circuits operating at less than line voltage
Black insulation: AC circuits operating at less than line voltage
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
13
Series SF Highly Flexible TPE
Servo Cable
600/1000 V, PVC/Nylon, TPE
Operating Temperature
• -25°C to +90°C (static)
• -5°C to +90°C (dynamic)
UL TC-ER (600 V)
UL WTTC (1000 V)
CSA AWM I/II A/B FT4
CSA CIC/TC
CE LVD 2006/95/EC
Designed specifically for connecting
power between the supply and servo
motors, drives, and controllers, Series SF
cables feature a flexible TPE jacket
and PVC/nylon insulation, making them
suitable for flexing applications that
require continuous movement.
Conductor Color Coding
• Multiconductor: 1 green/yellow
and 3 black numbered
• Pairs: Black-red, black-white
Materials
• Stranded tinned copper
conductors
• PVC/nylon insulation
• Foil + braid shielding
Aluminum/polyester foil
Tinned copper braid,
85% coverage
• Orange thermoplastic
elastomer jacket
Features
• UL Sunlight Resistant
• UL Oil Res. I/II
• 10x bend radius
• Two configurations
1. Power cable
2. Composite cable for power
and control
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-600: Highly flexible
cross-linked elastomer
• FIT-650: Chemical/temperature-resistant cross-linked
fluoroelastomer
Flexible Power Servo Cable
4 conductors for power/ground
Part No.
Conductors
SF61118CY
SF61116CY
SF61114CY
SF61112CY
SF61110CY
SF61108CY
4
4
4
4
4
4
Wire Size
AWG
mm2
18
0.96
16
1.32
14
2.09
12
3.31
10
5.32
8
8.50
Stranding
AWG
mm
19/30
19 x 0.25
26/30
26 x 0.25
41/30
41 x 0.25
65/30
65 x 0.25
105/30
105 x 0.25
168/30
168 x 0.25
Nominal Diameter
Inch
mm
0.382
9.70
0.406
10.31
0.440
11.18
0.506
12.85
0.603
15.32
0.785
19.94
Jacket Thickness
Inch
mm
0.055
1.40
0.055
1.40
0.055
1.40
0.065
1.65
0.065
1.65
0.065
1.65
Flexible Composite Servo Cable
4 conductors for power/ground + 2 individually shielded pairs for brake or temperature control
Part No.
Conductors
SF61220CY
4 + 2 pairs
SF61221CY
4 + 2 pairs
SF61222CY
4 + 2 pairs
SF61223CY
4 + 2 pairs
SF61224CY
4 + 2 pairs
14
Wire Size
AWG
mm2
16 pwr
1.32
18 pr
0.96
14 pwr
2.09
18 pr
0.96
12 pwr
3.31
16 pr
1.32
10 pwr
5.37
16 pr
1.32
8 pwr
8.50
16 pr
1.32
Stranding
AWG
mm
26/30
26 x 0.25
19/30
19 x 0.25
41/30
41 x 0.25
19/30
19 x 0.25
65/30
65 x 0.25
26/30
26 x 0.25
105/30
105 x 0.25
26/30
26 x 0.25
168/30
168 x 0.25
26/30
26 x 0.25
Nominal Diameter
Inch
mm
Jacket Thickness
Inch
mm
0.590
14.99
0.065
1.65
0.618
15.70
0.065
1.65
0.674
17.12
0.065
1.65
0.757
19.23
0.065
1.65
0.943
23.95
0.085
2.16
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Series V VFD Cable
Enhanced Design for Superior Performance in
Variable-Frequency Drives
600/1000 V Shielded, 3 Conductor
Series V cables for variable-frequency
drives (VFD) set the standard in highperformance and reliable connectivity. Their
specially formulated cross-linked polyethylene insulation provides superior corona
resistance, low capacitance for longer runs,
and excellent low-temperature properties.
A symmetrical design places the ground
wires in the interstices of the conductors for
uniform conductor-to-ground capacitance
and impedance.
Smaller gauge cable feature a combination
foil + braid shield to offer exceptional
EMI/RFI protection in noisy environments.
On larger gauge cable, a double
copper tape is used to provide the same
noise-free operation.
This uniformity reduces the probability of
motor damage from common-mode current.
UL RHW-2 (16 – 2 AWG)
UL XHHW-2
UL TC-ER
UL 1000V Flexible Motor
Supply Cable
CSA AWM I/II A/B FT4
CE LVD 2006/95/EC
Pennsylvania MSHA
Operating Temperature
• -40°C to +90°C
Conductor Color Coding
• Black, numbered
Materials
• Stranded tinned copper
conductors
• Stranded tinned copper
ground wires
• Cross-linked polyethylene
insulation (XLPE)
• S
hielding
16 – 4 AWG:
Aluminum/polyester/aluminum
foil and tinned copper braid
with 85% coverage
2 – 4/0 AWG:
Double-layer copper tape
• Black premium PVC jacket
Voltage
• 600 V (UL TC-ER)
• 1000 V (UL Motor Supply)
Features
• UL Direct Burial
• UL Sunlight Resistant
• 10x bend radius
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, made to order
FIT® Tubing Recommendations
• FIT-221: General-purpose
cross-linked polyolefin
• FIT-321V: Low-shrinktemperature, flame-retardant
cross-linked polyolefin
Alpha Series V VFD cables are compatible
with drives from all major manufacturers.
Three-Conductor VFD Cables
Part No.
V16316
V16314
V16312
V16310
V16308
V16306
V16304
V16302
V16001
V16000
V16020
V16030
V16040
Wire Size
AWG
mm2
16
1.32
14
2.09
12
3.31
10
5.37
8
8.53
6
13.57
4
21.58
2
34.32
1
43.28
1/0
54.58
2/0
68.85
3/0
86.9
4/0
109
Stranding
AWG
mm
26/30
26 x 0.25
41/30
41 x 0.25
65/30
65 x 0.25
105/30
105 x 0.25
133/29
133 x 0.28
133/27
133 x 0.36
133/25
133 x 0.45
133/23
133 x 0.57
133/22
133 x 0.64
133/21
133 x 0.72
133/20
133 x 0.81
133/19
133 x 0.91
133/18
133 x 1.02
Shielding
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Tape
Tape
Tape
Tape
Tape
Tape
Insulation Thickness
Inch
mm
0.046
1.17
0.046
1.17
0.046
1.17
0.047
1.19
0.061
1.55
0.061
1.55
0.061
1.55
0.061
1.55
0.056
1.42
0.056
1.42
0.056
1.42
0.056
1.42
0.056
1.42
Jacket Thickness
Inch
mm
0.050
1.27
0.065
1.65
0.065
1.65
0.065
1.65
0.065
1.65
0.085
2.15
0.085
2.15
0.085
2.15
0.085
2.15
0.085
2.15
0.085
2.15
0.085
2.15
0.085
2.15
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Nominal Diameter
Inch
mm
0.468
11.89
0.538
13.67
0.578
14.68
0.642
16.31
0.798
20.27
0.924
23.47
1.050
26.67
1.157
29.39
1.197
30.48
1.294
32.77
1.399
35.56
1.517
38.53
1.653
41.98
15
Series V VFD Cable
Enhanced Design for Superior Performance in
Variable-Frequency Drives
600/1000 V Shielded, 4 Conductor
Series V cables for variable-frequency
drives (VFD) set the standard in highperformance and reliable connectivity. Their
specially formulated cross-linked polyethylene insulation provides superior corona
resistance, low capacitance for longer runs,
and excellent low-temperature properties.
A symmetrical design places the ground
wires in the interstices of the conductors for
uniform conductor-to-ground capacitance
and impedance.
Smaller gauge cable feature a combination
foil + braid shield to offer exceptional
EMI/RFI protection in noisy environments.
On larger gauge cable, a double
copper tape is used to provide the same
noise-free operation.
This uniformity reduces the probability of
motor damage from common-mode current.
UL RHW-2 (16 – 2 AWG)
UL XHHW-2
UL TC-ER
UL 1000V Flexible Motor
Supply Cable
CSA AWM I/II A/B FT4
CE LVD 2006/95/EC
Pennsylvania MSHA
Operating Temperature
• -40°C to +90°C
Conductor Color Coding
• Black, numbered
Materials
• Stranded tinned copper
conductors
• Stranded tinned copper
ground wires
• Cross-linked polyethylene
insulation (XLPE)
• S
hielding
16 – 4 AWG:
Aluminum/polyester/aluminum
foil and tinned copper braid
with 85% coverage
2 – 4/0 AWG:
Double-layer copper tape
• Black premium PVC jacket
Voltage
• 600 V (UL TC-ER)
• 1000 V (UL Motor Supply)
Features
• UL Direct Burial
• UL Sunlight Resistant
• 10x bend radius
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, made to order
FIT® Tubing Recommendations
• FIT-221: General-purpose
cross-linked polyolefin
• FIT-321V: Low-shrinktemperature, flame-retardant
cross-linked polyolefin
Alpha Series V VFD cables are compatible
with drives from all major manufacturers.
Four-Conductor VFD Cable with 14 AWG (2.09) Brake Pair
Part No.
V16116
V16114
V16112
V16110
V16108
Wire Size
AWG
mm2
16
1.32
14
2.09
12
3.31
10
5.37
8
8.53
Stranding
AWG
mm
26/30
26 x 0.25
41/30
41 x 0.25
65/30
65 x 0.25
105/30
105 x 0.25
133/29
133 x 0.28
Shielding
Foil/Braid
Foil/Braid
Foil/Braid
Foil/Braid
Foil/Braid
Insulation Thickness
Inch
mm
0.047
1.19
0.047
1.19
0.047
1.19
0.047
1.19
0.061
1.55
Jacket Thickness
Inch
mm
0.065
1.65
0.065
1.65
0.065
1.65
0.085
2.15
0.085
2.15
Nominal Diameter
Inch
mm
0.717
18.21
0.743
18.87
0.785
19.94
0.875
22.23
1.032
26.21
Jacket Thickness
Inch
mm
0.065
1.65
0.065
1.65
0.065
1.65
0.085
2.15
0.086
2.15
0.086
2.15
0.086
2.15
0.088
2.15
Nominal Diameter
Inch
mm
0.547
13.89
0.584
14.83
0.633
16.08
0.746
18.95
0.920
23.37
1.017
25.83
1.157
29.39
1.308
33.22
Four-Conductor VFD Cable
Part No.
V16016
V16014
V16012
V16010
V16008
V16006
V16004
V16002
16
Wire Size
AWG
mm2
16
1.32
14
2.09
12
3.31
10
5.37
8
8.53
6
13.57
4
21.58
2
34.32
Stranding
AWG
mm
26/30
26 x 0.25
41/30
41 x 0.25
65/30
65 x 0.25
105/30
105 x 0.25
133/29
133 x 0.28
133/27
133 x 0.36
133/25
133 x 0.45
133/23
133 x 0.57
Shielding
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Foil + Braid
Insulation Thickness
Inch
mm
0.047
1.19
0.047
1.19
0.047
1.19
0.047
1.19
0.061
1.55
0.061
1.55
0.061
1.55
0.061
1.55
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Series V-Flex VFD Cable
Enhanced Design and TPE Jackets for Flexibility
600/1000 V Shielded
Conductor Color Coding
• 1 green or green/yellow and
3 black, numbered
UL RHW-2 (16 – 2 AWG)
UL XHHW-2
UL TC-ER
UL 1000V Flexible Motor
Supply Cable
CSA CIC/TC
CSA FT4
CE LVD 2006/95/EC
Pennsylvania MSHA
Operating Temperature
• -40°C to +90°C
Materials
• Stranded tinned copper
conductors
• Stranded tinned copper
ground wires
• Cross-linked polyethylene
insulation (XLPE)
• Shielding
16 – 4 AWG:
Aluminum/polyester/aluminum
foil and tinned copper braid
with 85% coverage
2 – 4/0 AWG:
Double-layer copper tape
• Thermoplastic elastomer jacket
Features
• Oil Res. I/II
• UL Sunlight Resistant
• CSA -40°C Cold Bend
• 5x bend radius
• Suitable for use in Class I,
Division 2 locations per Article
501 of the National Electric Code
Availability
Bulk, made to order
FIT® Tubing Recommendations
• FIT-221: General-purpose
cross-linked polyolefin
• FIT-321V: Low-shrinktemperature, flame-retardant
cross-linked polyolefin
Voltage
• 600 V (UL TC-ER)
• 1000 V (UL Motor Supply)
Four-Conductor VFD Cables
Part
No.
VF16016
VF16014
VF16012
VF16010
VF16008
VF16006
VF16004
Wire Size
AWG
mm2
16
1.32
14
2.08
12
3.29
10
5.32
8
8.61
6
13.60
4
21.60
Stranding
AWG
mm
26/30
26 x 0.254
41/30
41 x 0.254
65/30
65 x 0.254
105/30
105 x 0.254
133/29
133 x 0.287
133/27
133 x 0.361
133/25
133 x 0.455
Insulation Thickness
Inch
mm
0.046
1.17
0.046
1.17
0.046
1.17
0.047
1.19
0.061
1.55
0.061
1.55
0.061
1.55
Designed to Excel in
VFD Systems
Series V and V-Flex cables
give you the features you
need for high-performance
VFD applications.
Pressure-extruded cross-linked
polyethylene insulation (XLPE)
and symmetrical cable geometry
combine to provide the electrical
characteristics required for
precise control and long life.
Core OD
Inch
mm
0.375
9.53
0.414
10.52
0.461
11.71
0.540
13.72
0.701
17.81
0.798
20.27
0.934
23.72
Jacket Thickness Nominal Diameter
Inch
mm
Inch
mm
0.065
1.65
0.545
13.84
0.065
1.65
0.584
14.83
0.065
1.65
0.631
16.03
0.085
2.16
0.75
19.05
0.086
2.18
0.92
23.37
O.086
2.18
1.017
25.83
O.086
2.18
1.157
29.39
XLPE Insulation
Lower Capacitance
Excellent Corona Resistance
Longer Transmission Distances
Round Geometry
Enhances Uniform
Electrical Properties
Allows IP67/NEMA 6
Liquid-Tight Sealing
Double Shielding
EMI Protection
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
17
Series V VFD and V-Flex
Cable Selection Guide
Drive
HP
Wire
Gauge
(AWG)
Full Load
Current,
Amps
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
60
75
16
16
16
16
16
—
—
—
—
—
—
—
—
—
—
—
—
4.4
6.4
8.4
12.0
13.6
—
—
—
—
—
—
—
—
—
—
—
—
Drive
HP
Wire
Gauge
(AWG)
1/2
3/4
1
1-1/2
2
3
5
7-1/2
10
15
20
25
30
40
50
60
75
100
125
150
200
16
16
16
16
16
16
16
16
16
12
10
8
8
6
4
2
2
1/0
2/0
4/0
—
18
115 VAC, 3 Phase
Alpha Wire Part No.
Series V
Series VF
3 Cond.
4 Cond.
4 Cond.
V16316
V16016
VF16016
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
460 VAC, 3 Phase
Alpha Wire Part No.
Full Load
Current,
Series V
Series VF
Amps
3 Cond.
4 Cond.
4 Cond.
1.1
1.6
2.1
3.0
3.4
V16316
V16016
VF16016
4.8
7.6
11
14
21
V16312
V16012
VF16012
27
V16310
V16010
VF16010
34
V16308
V16008
VF16008
40
V16308
V16008
VF16008
52
V16306
V16006
VF16006
65
V16304
V16004
VF16004
77
—
V16002
VF16302
96
—
V16002
VF16302
124
—
V16000
—
156
—
V16020
—
180
—
V16040
—
—
—
—
—
Wire Gauge
(AWG)
Full Load
Current,
Amps
16
16
16
16
16
16
14
12
10
8
6
4
2
2
1/0
2/0
4/0
2.2
3.2
4.2
6.0
6.8
9.6
15.2
22
28
42
54
68
80
104
130
154
192
Wire Gauge
(AWG)
16
16
16
16
16
16
16
16
16
14
12
10
10
8
6
4
2
2
1/0
2/0
4/0
230 VAC, 3 Phase
Alpha Wire Part No.
Series V
VF
3 Cond.
4 Cond.
4 Cond.
V16316
V16016
VF16016
V16314
V16014
VF16014
V16312
V16012
VF16012
V16310
V16010
VF16010
V16308
V16008
VF16008
V16306
V16006
VF16006
V16304
V16004
VF16004
V16304
V16004
—
—
V16002
—
V16000
—
—
V16020
—
—
V16040
—
—
575 VAC, 3 Phase
Alpha Wire Part No.
Full Load
Current,
Series V
VF
Amps
3 Cond.
4 Cond.
4 Cond.
0.9
1.3
1.7
2.4
2.7
V16316
V16016
VF16016
3.9
6.1
9
11
17
V16314
V16014
VF16014
22
V16312
V16012
VF16012
27
V16310
V16010
VF16010
32
V16310
V16010
VF16010
41
V16308
V16008
VF16008
52
V16306
V16006
VF16006
62
V16304
V16004
VF16004
77
—
V16002
VF16302
99
—
V16002
VF16302
125
—
V16000
—
144
—
V16020
—
192
—
V16040
—
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
An Extensive Range of Flexible
Cable Solutions
Alpha Wire’s industrial cables
are well suited to the widest
range of industrial applications,
from the factory floor to process
controls to wind turbines and
light-duty VFD applications. We
offer an extensive range of cables
for general needs such as control
wiring in both stationary and
moving components. We also offer
application-specific configurations
for use with motors, drives, and
servo systems.
In addition to our AWIS cable
family, we offer tougher flexible
alternatives in our Xtra-Guard®
65000, 85000, 86000 and
87000 Series cables with up to
14 million flex cycles. For a smaller,
lighter flexible control cable, our
EcoFlex® flexible control cable
and EcoFlex® PUR continuous
flex cable can provide up to 55%
weight and 40% size savings, and
both are completely recyclable.
Our flexible motor supply cable
provides exceptional performance
in a variety of motor and drive
applications. We can also create
the ideal custom cable for your
specific application.
General Application
Cable
Stationary
Series M
Stationary/Minimal Flex
Series P
Moderate Flexing
EcoFlex Cable
Xtra-Guard Standard Flex
(65000 Series)
EcoFlex PUR
Continuous Flex
Series XM
High Flexing
Series F
Xtra-Guard
Continuous Flex Data
(86000 Series)
Xtra-Guard
Continuous Flex Control
(85000 Series)
Xtra-Guard Torsional Flex
(87000 Series)
Servomotors/Drives
Series SF
VFD Systems
Series V
Series V-Flex
Motor Supply
Flexible Motor Supply
Advantages
PVC jacket
Oil resistant (Oil Res. I)
TPE jacket
Improved oil and chemical resistance (Oil Res. I/II)
100% recyclable mPPE insulation/jacket
1 million flex cycles
RoHS and REACH compliant
Size and weight reduction
1 million flex cycles
PVC jacket
Polyurethane jacket, mPPE insulation
8 million flex cycles
Zero halogen
Saves space and weight
12 million flex cycles
Oil resistant (Oil Res. I)
20 million flex cycles
Improved oil and chemical resistance (Oil Res. I/II)
6 million flex cycles
PVC jacket
14 million flex cycles
PVC jacket
1 million flex cycles
TPE insulation, polyurethane jacket
TPE jacket
Enhanced flexibility for easy installation and routing
Improved oil and chemical resistance (Oil Res. I/II)
With or without brake/ground pairs
Oil resistant (Oil Res. I)
Low capacitance for extended runs
XLPE insulation for improved dielectric properties
Excellent corona resistance
Uniform geometry for reduced common-mode current
PVC jacket
Oil resistant (Oil Res. I)
Suited to light-duty flexing and VFD applications
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
19
Cables you trust.
Service you deserve.
Every application is critical and
cable failure is not an option
when the safety of equipment
and personnel is paramount.
Specify Alpha cable for rugged,
reliable performance, since the
integrity of your system is only as
robust as the products you use.
GLOBAL HEADQUARTERS
711 Lidgerwood Avenue
Elizabeth, NJ 07207-0711 USA
Toll Free: 1-800-52 ALPHA
Tel: 1-908-925-8000
Fax: 1-908-925-5411
E-mail: [email protected]
Custom cable is standard
Alpha Wire goes one step
further: manufacturing
custom cables to meet unique
applications—offering specific
conductor counts, shielding
options, jacket materials, and
versatile product designs. Our
custom cable orders are often
shipped in less than a week,
once again giving you products
with more convenience and
less delay.
EUROPE
Alpha Wire International
Saxon House
1 Downside | Sunbury-on-Thames
Middlesex | United Kingdom | TW16 6RT
Tel: 01 932 772 422
Fax: 01 932 772 433
E-mail: [email protected]
©2016 Alpha Wire. All rights reserved. Specifications subject to change.
Consult Alpha Wire for latest specifications. Service and support,
second-to-none
Selecting the correct cable
for your critical application is
essential to overall system
reliability, performance, and
safety. So we make it easy
for you to select the right
Alpha cable for your specific
application. Our online
resources include a wire and
cable selection guide, technical
information, full product
catalog, and a distributor
locator to make it easy to
select and get the cable you
need. Can’t find what you’re
looking for? Design the cable
to your specification. It’s easy,
just visit www.alphawire.com!
ASIA PACIFIC
Alpha Wire
Silver Center | Room 1712
North Shanxi Road 1388
Shanghai | China | 200060
Tel: +86-21-61498201/61498205
Fax: +86-21-61498001
E-mail: [email protected]
Lit. No. AWIS-Cat-1601
Supersedes: AWIS-Cat-1509