catalog

Xtra-Guard® 1
Performance Cable
Xtra-Guard 1 Cable
Setting the standard in tough PVC cable
Alpha Wire’s Xtra-Guard cable
brings performance and reliability
to the biggest challenges in
the toughest environments.
No matter what extremes your
application faces, you’ll find an
Xtra-Guard cable that excels in
meeting your requirements. Years
of abuse in some of the harshest
environments have proven
Xtra-Guard means peace of mind.
With its premium PVC insulation
and jacket, Xtra-Guard 1 cable
strips cleanly and routes easily.
It’s available in multiconductor
and multipair configurations with
300 V and 600 V ratings.
Features
• C
olor-coded, tinned copper
conductors
• P
remium-grade PVC insulation
and jacket for easier cable
routing in small spaces
• U
nshielded, foil shielded, or
Supra-Shield® foil/braid
• 105°C temperature rating
• U
L VW-1, UL 1685,
and CSA FT-4
flammability rating
• NFPA 79 compliant
• N
ylon ripcord for easy
jacket stripping
• W
ide range of cable
configurations and lengths in
stock, ready to ship same day
2
• N
o minimum order quantity on
lengths of 100’, 500’, and 1000’
• Samples of any product can be
shipped next day free of charge
SLATE
BEIGE
WHITE
RED
BLACK
BLUE
GREEN
YELLOW
ORANGE
Applications
• EIA RS-232 interface
• High technology applications in
controlled environments
• Medical electronics
• Point-of-sale equipment
• Computer peripherals
• Industrial process controls
Xtra-Guard cables are available in
a range of long-lasting colors for
fast, easy identification, for safety
reasons, and for matching the
color of your system.
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard shielding options
Alpha Wire offers Xtra-Guard 1
cables in three shielding options
to handle virtually any electrical
environment.
Unshielded
Unshielded cables provide the
smallest cable diameter for
use in low-noise controlled
environments.
Foil shielded
Foil-shielded cables use a sturdy
aluminum/polyester shield for
moderate EMI needs, especially
at lower frequencies. A tinned
copper drain wire makes
grounding the cable easy. Foil
shields allow lighter weights and
smaller cables.
Supra-Shield®
Alpha’s exclusive Supra-Shield
cables combine a triple-layer
aluminum/polyester/aluminum foil
with a tinned copper braid shield
with tight 70% coverage.
Supra-Shield offers exceptional
EMI performance and flexibility
to protect against noise and
maintain overall system integrity.
The combination of foil and
braid offers better shielding
effectiveness than either approach
alone against both low- and highfrequency noise.
There’s an Xtra-Guard cable for any application hazard
Xtra-Guard 1
High performance in a tough PVC jacket
Xtra-Guard 2
Added abrasion resistance to withstand mechanical abuse
Xtra-Guard 3
Direct burial—no conduit needed
Xtra-Guard 4
Advanced temperature and chemical performance
Xtra-Guard 5
Maximum chemical and temperature performance
Xtra-Guard Flex
Continuous flex applications
Xtra-Guard Industrial Ethernet
Cat 5e that’s beyond factory tough
70% Tinned
Copper Braid
Easy-To-Terminate,
Continuous Contact
Drain Wire
Triple-Laminate Foil
with 25% Overlap
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
3
Xtra-Guard 1 > Multiconductor > Unshielded > 300 V
Xtra-Guard® 1
High performance
300 V Unshielded, Multiconductor
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.127 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Part Number
Conductors
5920
5921
5922
5923
5924
5925
2
3
4
6
7
8
Nominal Diameter
Inch
mm
0.138
3.51
0.144
3.66
0.153
3.89
0.174
4.42
0.174
4.42
0.185
4.70
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
Operating Temperature
26 AWG (0.14 mm2)
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
(page 31)
• 20, 18, 16 AWG: Chart D
(page 30)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5666
5667
5668
5669
5670
5671
5672
5673
2
3
4
6
7
8
10
15
Materials
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
• S
tranded tinned
copper conductors
• Premium PVC insulation
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
4
Nominal Diameter
Inch
mm
0.146
3.71
0.152
3.86
0.162
4.11
0.186
4.72
0.186
4.72
0.198
5.03
0.224
5.69
0.248
6.30
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5012C
5013C
5014C
5016C
5018C
5020C
5020/15C
5020/20C
5020/25C
5020/30C
5020/40C
5020/50C
2
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.156
3.96
0.163
4.14
0.175
4.45
0.201
5.11
0.215
5.46
0.244
6.20
0.271
6.88
0.300
7.62
0.332
8.43
0.350
8.89
0.390
9.91
0.429
10.90
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multiconductor > Unshielded > 300 V
Xtra-Guard® 1
High Performance
300 V Unshielded, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
(page 31)
• 20, 18, 16 AWG: Chart D
(page 30)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned
copper conductors
• Premium PVC insulation
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
Part Number
Conductors
5002C
5003C
5004C
5006C
5008C
5010C
5010/15C
5010/20C
5010/25C
5010/30C
5010/40C
5010/50C
5010/60C
2
3
4
6
8
10
15
20
25
30
40
50
60
Nominal Diameter
Inch
mm
0.168
4.27
0.176
4.47
0.189
4.80
0.219
5.56
0.235
5.97
0.268
6.81
0.299
7.59
0.331
8.41
0.368
9.35
0.389
9.88
0.434
11.02
0.478
12.14
0.518
13.16
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
5052C
5053C
5054C
5056C
5058C
5060C
5060/15C
5060/20C
5060/25C
5060/30C
5060/40C
5060/50C
2
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.208
5.28
0.219
5.56
0.238
6.05
0.280
7.11
0.302
7.67
0.348
8.84
0.391
9.93
0.437
11.10
0.488
12.40
0.517
13.13
0.622
15.80
0.684
17.37
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
5
Xtra-Guard 1 > Multiconductor > Unshielded > 300 V
Xtra-Guard® 1
High Performance
300 V Unshielded, Multiconductor
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
(page 31)
• 2
0, 18, 16 AWG: Chart D
(page 30)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned
copper conductors
• P
remium PVC insulation
• Nylon ripcord
• P
remium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
Part Number
Conductors
5062/1C*
5062C
5063/1C*
5063C
5064C
5066C
5068C
5070C
5070/15C
5070/20C
5070/25C
5070/30C
5070/40C
5070/50C
5070/60C
2
2
3
3
4
6
8
10
15
20
25
30
40
50
60
Nominal Diameter
Inch
mm
0.226
5.74
0.226
5.74
0.238
6.05
0.238
6.05
0.259
6.58
0.307
7.80
0.332
8.43
0.384
9.75
0.433
11.00
0.484
12.29
0.542
13.77
0.617
15.67
0.688
17.48
0.758
19.25
0.881
22.38
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
0.083
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
5072/1C*
5072C
5073/1C*
2
2
3
5073C
5074C
5076C
5078C
5080C
5080/15C
5080/20C
5080/25C
5080/30C
5080/40C
5080/50C
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.250
6.35
0.250
6.35
0.264
6.71
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.264
0.288
0.343
0.372
0.432
0.488
0.547
0.656
0.694
0.775
0.917
0.032
0.032
0.032
0.032
0.032
0.032
0.053
0.053
0.053
0.083
0.083
6.71
7.32
8.71
9.45
10.97
12.40
13.89
16.66
17.63
19.69
23.29
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
2.11
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
6
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multiconductor > Unshielded > 300 V
Xtra-Guard® 1
High Performance
300 V Unshielded, Multiconductor
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2343 VW-1
CSA CMG FT4
Part Number
Conductors
5201C
5202C
5203C
5204C
5206C
7
12
15
19
37
Operating Temperature
• Chart E (page 31)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned
copper conductors
• Premium PVC insulation
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
22 AWG (0.35 mm2)
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
Nominal Diameter
Inch
mm
0.263
6.68
0.313
7.95
0.333
8.46
0.350
8.89
0.438
11.13
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5210/2C
5211C
5212C
5213C
5214C
5214/25C
5215C
5216C
2
7
12
15
19
25
27
37
Nominal Diameter
Inch
mm
0.230
5.84
0.281
7.14
0.338
8.59
0.361
9.17
0.380
9.65
0.430
10.92
0.438
11.13
0.480
12.19
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5220/2C
5220C
5221C
5222C
5223C
5224C
5224/25C
5225C
5226C
2
5
7
12
15
19
25
27
37
Nominal Diameter
Inch
mm
0.246
6.25
0.288
7.32
0.305
7.75
0.371
9.42
0.398
10.11
0.420
10.67
0.478
12.14
0.487
12.37
0.536
13.61
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
7
Xtra-Guard 1 > Multiconductor > Unshielded > 600 V
Xtra-Guard® 1
High Performance
600 V Unshielded, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
UL CM
UL AWM 2501 VW-1
UL MTW
CSA AWM I/II A/B FT4
Part Number
Conductors
5402
5404
5405
5409
5409/19
2
4
5
9
19
Conductor Color Coding
• Chart E (page 31)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
20 AWG (0.56 mm2)
Operating Temperature
• –30°C to +105°C
• –30°C to +90°C (Dry MTW)
• –30°C to +60°C (Wet MTW)
Nominal Diameter
Inch
mm
0.318
8.08
0.358
9.09
0.385
9.78
0.473
12.01
0.601
15.27
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.032 (0.81 mm)
Part Number
Conductors
5413
5414
5419
5419/12
5419/15
5419/19
5419/25
3
4
9
12
15
19
25
Nominal Diameter
Inch
mm
0.350
8.89
0.377
9.58
0.503
12.78
0.554
14.07
0.601
15.27
0.641
16.28
0.742
18.85
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
18 AWG (0.81 mm2)
Materials
• S
tranded tinned
copper conductors
• P
remium PVC insulation
• Nylon ripcord
• P
remium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
Part Number
Conductors
5422
5423
5424
5425
5427
5429
5429/15
5429/19
5429/25
2
3
4
5
7
9
15
19
25
Nominal Diameter
Inch
mm
0.352
8.94
0.369
9.37
0.399
10.13
0.432
10.97
0.466
11.84
0.535
13.59
0.643
16.33
0.686
17.42
0.796
20.22
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
8
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multiconductor > Unshielded > 600 V
Xtra-Guard® 1
High Performance
600 V Unshielded, Multiconductor
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.032 (0.81 mm)
UL CM
UL AWM 2501 VW-1
UL MTW
CSA AWM I/II A/B FT4
Part Number
Conductors
5434
5435
5437
5439
5439/12
5439/15
5439/19
5439/25
4
5
7
9
12
15
19
25
Nominal Diameter
Inch
mm
0.428
10.87
0.464
11.79
0.502
12.75
0.579
14.71
0.641
16.28
0.698
17.73
0.746
18.95
0.908
23.06
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.083
2.11
0.083
2.11
Operating Temperature
• –30°C to +105°C
• –30°C to +90°C (Dry MTW)
• –30°C to +60°C (Wet MTW)
Conductor Color Coding
• Chart E (page 31)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned
copper conductors
• Premium PVC insulation
• Nylon ripcord
• Premium PVC jacket
• UV resistant
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
Part Number
Conductors
5442
5443
5444
5445
5447
5449
5449/12
5449/15
5449/25
2
3
4
5
7
9
12
15
25
Nominal Diameter
Inch
mm
0.406
10.31
0.428
10.87
0.464
11.79
0.505
12.83
0.547
13.89
0.634
16.10
0.703
17.86
0.767
19.48
0.998
25.35
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.083
2.11
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
9
Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V
Xtra-Guard® 1
High Performance
300 V Foil Shielded, Multiconductor
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.127 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Part Number
Conductors
5926
5927
5928
5929
5930
5931
2
3
4
6
7
8
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
(page 31)
• 20, 18, 16 AWG: Chart D (page 30)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• A
luminum/polyester foil shield,
with 25% overlap and foil
facing inward
• T
inned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• P
remium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
10
Nominal Diameter
Inch
mm
0.142
3.61
0.148
3.76
0.157
3.99
0.178
4.52
0.178
4.52
0.189
4.80
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5674
5675
5676
5677
5678
5679
5680
5681
2
3
4
6
7
8
10
15
Nominal Diameter
Inch
mm
0.150
3.81
0.156
3.96
0.166
4.22
0.190
4.83
0.190
4.83
0.202
5.13
0.228
5.79
0.252
6.40
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5092C
5093C
5094C
5096C
5098C
5100C
5100/15C
5100/20C
5100/25C
5100/30C
5100/40C
5100/50C
5100/60C
5100/70C
2
3
4
6
8
10
15
20
25
30
40
50
60
70
Nominal Diameter
Inch
mm
0.160
4.06
0.167
4.24
0.179
4.55
0.205
5.21
0.219
5.56
0.248
6.30
0.275
6.99
0.304
7.72
0.336
8.53
0.354
8.99
0.394
10.01
0.433
11.00
0.468
11.89
0.505
12.83
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V
Xtra-Guard® 1
High Performance
300 V Foil Shielded, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart E
(page 31)
• 20, 18, 16 AWG: Chart D (page 30)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Aluminum/polyester foil shield,
with 25% overlap and foil
facing inward
• Tinned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Part Number
Conductors
5192C
5193C
5194C
5196C
5198C
5199/10C
5199/15C
5199/20C
5199/25C
5199/30C
5199/40C
5199/50C
5199/60C
5199/70C
2
3
4
6
8
10
15
20
25
30
40
50
60
70
Nominal Diameter
Inch
mm
0.172
4.37
0.180
4.57
0.193
4.90
0.223
5.66
0.239
6.07
0.272
6.91
0.303
7.70
0.335
8.51
0.372
9.45
0.393
9.98
0.438
11.13
0.482
12.24
0.522
13.26
0.606
15.39
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
5462C
5463C
5464C
5466C
5468C
5470C
5470/15C
5470/20C
5470/25C
5470/30C
5470/40C
5470/50C
2
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.212
5.38
0.223
5.66
0.242
6.15
0.284
7.21
0.306
7.77
0.352
8.94
0.395
10.03
0.441
11.20
0.492
12.50
0.521
13.23
0.626
15.90
0.688
17.48
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
11
Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V
Xtra-Guard® 1
High Performance
300 V Foil Shielded, Multiconductor
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
(page 31)
• 20, 18, 16 AWG: Chart D (page 30)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• A
luminum/polyester foil shield,
with 25% overlap and foil
facing inward
• T
inned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• P
remium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
Part Number
Conductors
5382C
5382/1C*
5383C
5383/1C*
5384C
5386C
5388C
5390C
5390/15C
5390/20C
5390/25C
5390/30C
5390/40C
5390/50C
5390/60C
2
2
3
3
4
6
8
10
15
20
25
30
40
50
60
Nominal Diameter
Inch
mm
0.230
5.84
0.230
5.84
0.242
6.15
0.242
6.15
0.263
6.68
0.311
7.90
0.336
8.53
0.388
9.86
0.437
11.10
0.488
12.40
0.588
14.94
0.621
15.77
0.692
17.58
0.762
19.35
0.885
22.48
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
0.053
1.35
0.083
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
5362C
5362/1C*
5363C
5363/1C*
5364C
5366C
5368C
5370C
5370/15C
5370/20C
5370/25C
5370/30C
5370/40C
2
2
3
3
4
6
8
10
15
20
25
30
40
Nominal Diameter
Inch
mm
0.254
6.45
0.254
6.45
0.268
6.81
0.268
6.81
0.292
7.42
0.347
8.81
0.376
9.55
0.436
11.07
0.492
12.50
0.593
15.06
0.660
16.76
0.698
17.73
0.779
19.79
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
0.083
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
12
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V
Xtra-Guard® 1
High Performance
300 V Foil Shielded, Multiconductor
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2343 VW-1
CSA CMG FT4
Part Number
Conductors
5599/3C
5599/5C
5599/7C
5599/12C
5599/15C
5599/19C
5599/27C
3
5
7
12
15
19
27
Nominal Diameter
Inch
mm
0.229
5.82
0.254
6.45
0.267
6.78
0.317
8.05
0.337
8.56
0.354
8.99
0.405
10.29
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• Chart E (page 31)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Aluminum/polyester foil shield,
with 25% overlap and foil
facing inward
• Tinned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5580/2C
5580C
5581C
5582C
5583C
5584C
5586C
2
5
7
12
15
19
37
Nominal Diameter
Inch
mm
0.234
5.94
0.270
6.86
0.285
7.24
0.342
8.69
0.365
9.27
0.384
9.75
0.484
12.29
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5560/2C
5560C
5561C
5562C
5563C
5564C
2
5
7
12
15
19
Nominal Diameter
Inch
mm
0.250
6.35
0.292
7.42
0.309
7.85
0.375
9.53
0.402
10.21
0.424
10.77
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
13
Xtra-Guard 1 > Multiconductor > Foil Shielded > 600 V
Xtra-Guard® 1
High Performance
600 V Foil Shielded, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
UL AWM 2501 VW-1
CSA AWM I/II A/B FT4
UL MTW
Part Number
Conductors
5410/2
5410/3
5410/4
5410/5
5410/9
5410/12
2
3
4
5
9
12
Operating Temperature
• Chart E (page 31)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
20 AWG (0.56 mm2)
• –30°C to +105°C
• –30°C to +90°C (Dry MTW)
• –30°C to +60°C (Wet MTW)
Conductor Color Coding
Nominal Diameter
Inch
mm
0.322
8.18
0.337
8.56
0.362
9.19
0.389
9.88
0.477
12.12
0.525
13.34
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.032 (0.81 mm)
Part Number
Conductors
5420/3
5420/4
5420/5
5420/7
5420/9
5420/12
3
4
5
7
9
12
Materials
Nominal Diameter
Inch
mm
0.354
8.99
0.381
9.68
0.411
10.44
0.442
11.23
0.507
12.88
0.558
14.17
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
18 AWG (0.81 mm2)
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• A
luminum/polyester foil shield,
with 25% overlap and foil
facing inward
• T
inned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• P
remium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
Part Number
Conductors
5430/2
5430/3
5430/4
5430/5
5430/7
5430/9
5430/12
5430/15
5430/19
5430/25
2
3
4
5
7
9
12
15
19
25
Nominal Diameter
Inch
mm
0.356
9.04
0.373
9.47
0.403
10.24
0.436
11.07
0.470
11.94
0.539
13.69
0.595
15.11
0.647
16.43
0.690
17.53
0.800
20.32
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
14
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multiconductor > Foil Shielded > 600 V
Xtra-Guard® 1
High Performance
600 V Foil Shielded, Multiconductor
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.032 (0.81 mm)
UL AWM 2501 VW-1
CSA AWM I/II A/B FT4
UL MTW
Operating Temperature
Part Number
Conductors
5440/2
5440/3
5440/4
5440/5
5440/7
5440/9
5440/12
5440/15
2
3
4
5
7
9
12
15
• –30°C to +105°C
• –30°C to +90°C (Dry MTW)
• –30°C to +60°C (Wet MTW)
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
Conductor Color Coding
• Chart E (page 31)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Nominal Diameter
Inch
mm
0.380
9.65
0.399
10.13
0.432
10.97
0.468
11.89
0.506
12.85
0.583
14.81
0.645
16.38
0.702
17.83
Part Number
Conductors
5450/2
5450/3
5450/4
5450/5
5450/7
5450/12
2
3
4
5
7
12
Nominal Diameter
Inch
mm
0.410
10.41
0.432
10.97
0.468
11.89
0.509
12.93
0.551
14.00
0.707
17.96
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
Materials
• S
tranded tinned copper
conductors
• Premium PVC insulation
• Aluminum/polyester foil shield,
with 25% overlap and foil
facing inward
• Tinned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
15
Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multiconductor
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.127 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Part Number
Conductors
5932
5933
5934
5935
5936
5937
2
3
4
6
7
8
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
(page 31)
• 20, 18, 16 AWG: Chart D (page 30)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• Supra-Shield
foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• P
remium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
Nominal Diameter
Inch
mm
0.166
4.22
0.172
4.37
0.181
4.60
0.202
5.13
0.202
5.13
0.213
5.41
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5682
5683
5684
5685
5686
5687
5688
5689
2
3
4
6
7
8
10
15
Nominal Diameter
Inch
mm
0.174
4.42
0.180
4.57
0.190
4.83
0.214
5.44
0.214
5.44
0.226
5.74
0.252
6.40
0.276
7.01
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5112C
5113C
5114C
5116C
5118C
5120C
5120/15C
5120/20C
5120/25C
5120/30C
5120/40C
5120/50C
2
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.184
4.67
0.191
4.85
0.203
5.16
0.229
5.82
0.243
6.17
0.272
6.91
0.299
7.59
0.328
8.33
0.360
9.14
0.378
9.60
0.418
10.62
0.457
11.61
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
16
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart E
(page 31)
• 2
0, 18, 16 AWG: Chart D (page 30)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Part Number
Conductors
5102C
5103C
5104C
5106C
5108C
5110C
5110/15C
5110/20C
5110/25C
5110/30C
5110/40C
5110/50C
5110/60C
5110/70C
5110/80C
2
3
4
6
8
10
15
20
25
30
40
50
60
70
80
Nominal Diameter
Inch
mm
0.196
4.98
0.204
5.18
0.217
5.51
0.247
6.27
0.263
6.68
0.296
7.52
0.327
8.31
0.359
9.12
0.396
10.06
0.417
10.59
0.462
11.73
0.506
12.85
0.588
14.94
0.630
16.00
0.665
16.89
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
5152C
5153C
5154C
5156C
5158C
5160C
5160/15C
5160/20C
5160/25C
5160/30C
5160/40C
5160/50C
5160/60C
2
3
4
6
8
10
15
20
25
30
40
50
60
Nominal Diameter
Inch
mm
0.236
5.99
0.247
6.27
0.266
6.76
0.308
7.82
0.330
8.38
0.376
9.55
0.419
10.64
0.465
11.81
0.516
13.11
0.545
13.84
0.656
16.66
0.718
18.24
0.774
19.66
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
17
Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multiconductor
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
(page 31)
• 20, 18, 16 AWG: Chart D
(page 30)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• S
upra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• P
remium PVC jacket
• UV resistant
Part Number
Conductors
5162/1C*
5162C
5163/1C*
5163C
5164C
5166C
5168C
5170C
5170/15C
5170/20C
5170/25C
5170/30C
5170/40C
2
2
3
3
4
6
8
10
15
20
25
30
40
Nominal Diameter
Inch
mm
0.254
6.45
0.254
6.45
0.266
6.76
0.266
6.76
0.287
7.29
0.335
8.51
0.360
9.14
0.412
10.46
0.461
11.71
0.512
13.00
0.612
15.54
0.651
16.54
0.722
18.34
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
*Conductors color-coded per international standards: brown, blue, green/yellow.
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
5172/1C*
5172C
5173/1C*
5173C
5174C
5176C
5178C
5180C
5180/15C
5180/20C
5180/25C
2
2
3
3
4
6
8
10
15
20
25
Nominal Diameter
Inch
mm
0.278
7.06
0.278
7.06
0.292
7.42
0.292
7.42
0.316
8.03
0.371
9.42
0.400
10.16
0.460
11.68
0.516
13.11
0.617
15.67
0.690
17.53
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
*Conductors color-coded per international standards: brown, blue, green/yellow.
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
18
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multiconductor
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2343 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• Chart E (page 31)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
Part Number
Conductors
5300C
5301C
5302C
5303C
5304C
5305C
5306C
5307C
5
7
12
15
19
27
37
48
Nominal Diameter
Inch
mm
0.278
7.06
0.291
7.39
0.341
8.66
0.361
9.17
0.378
9.60
0.429
10.90
0.466
11.84
0.517
13.13
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5310C
5311C
5312C
5313C
5314C
5316C
5318C
5
7
12
15
19
37
60
Nominal Diameter
Inch
mm
0.294
7.47
0.309
7.85
0.366
9.30
0.389
9.88
0.408
10.36
0.508
12.90
0.608
15.44
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
5320/4C
5320C
5321C
5322C
5323C
5324C
5325C
5326C
4
5
7
12
15
19
27
37
Nominal Diameter
Inch
mm
0.299
7.59
0.316
8.03
0.333
8.46
0.399
10.13
0.426
10.82
0.448
11.38
0.515
13.08
0.564
14.33
Jacket Thickness
Inch
Mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
19
Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 600 V
Xtra-Guard® 1
High Performance
600 V Supra-Shield® Foil/Braid, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
UL AWM 2501 VW-1
CSA AWM I/II A/B FT4
UL MTW
Part Number
Conductors
5504
5507
5509/12
4
7
12
Conductor Color Coding
• C
hart E (page 31)
• J
acket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• S
upra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• N
ylon ripcord
• P
remium PVC jacket
• UV resistant
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
20 AWG (0.56 mm2)
Stranding: 10/30 (10 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
Operating Temperature
• –30°C to +105°C
• –30°C to +90°C (Dry MTW)
• –30°C to +60°C (Wet MTW)
Nominal Diameter
Inch
mm
0.386
9.80
0.442
11.23
0.549
13.94
Part Number
Conductors
5514
5517
5519
5519/12
5519/19
4
7
9
12
19
Nominal Diameter
Inch
mm
0.405
10.29
0.466
11.84
0.531
13.49
0.582
14.78
0.675
17.15
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
Part Number
Conductors
5522
5523
5524
5525
5527
5529
5529/12
5529/15
5529/19
2
3
4
5
7
9
12
15
19
Nominal Diameter
Inch
mm
0.380
9.65
0.397
10.08
0.427
10.85
0.460
11.68
0.494
12.55
0.563
14.30
0.619
15.72
0.677
17.20
0.760
19.30
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.083
2.11
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
20
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 600 V
Xtra-Guard® 1
High Performance
600 V Supra-Shield® Foil/Braid, Multiconductor
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.032 (0.81 mm)
UL AWM 2501 VW-1
CSA AWM I/II A/B FT4
UL MTW
Operating Temperature
• –30°C to +105°C
• –30°C to +90°C (Dry MTW)
• –30°C to +60°C (Wet MTW)
Part Number
Conductors
5532
5533
5534
5535
5537
5539
5539/12
5539/15
5539/19
2
3
4
5
7
9
12
15
19
Materials
• S
tranded tinned copper
conductors
• Premium PVC insulation
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.083
2.11
14 AWG (2.08 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
Conductor Color Coding
• C
hart E (page 31)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Nominal Diameter
Inch
mm
0.404
10.26
0.423
10.74
0.456
11.58
0.492
12.50
0.530
13.46
0.607
15.42
0.675
17.15
0.772
19.61
0.820
20.83
Part Number
Conductors
5542
5543
5544
5547
5549
5549/12
5549/15
2
3
4
7
9
12
15
Nominal Diameter
Inch
mm
0.434
11.02
0.456
11.58
0.492
12.50
0.575
14.61
0.668
16.97
0.777
19.74
0.841
21.36
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.083
2.11
0.083
2.11
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
21
Xtra-Guard 1 > Multipair > Unshielded > 300 V
Xtra-Guard® 1
High Performance
300 V Unshielded, Multipair
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Part No.
Pairs
5261C
5262C
5263C
5264C
5265C
5266C
5269C
5269/11C
5269/15C
5269/27C
5269/77C
1
2
3
4
5
6
9
11
15
27
77
Nominal Diameter
Inch
mm
0.156
3.96
0.212
5.38
0.224
5.69
0.243
6.17
0.264
6.71
0.286
7.26
0.332
8.43
0.357
9.07
0.401
10.19
0.512
13.00
0.904
22.96
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.083
0.81
Conductor Color Coding
• 24, 22 AWG: Chart B (page 29)
• 2
0, 18 AWG: Chart A (page 29)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• Nylon ripcord
• P
remium PVC jacket
• UV resistant
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
5021C
5022C
5023C
5024C
5025C
5026C
5029/15C
1
2
3
4
5
6
15
Nominal Diameter
Inch
mm
0.168
4.27
0.232
5.89
0.245
6.22
0.267
6.78
0.291
7.39
0.316
8.03
0.447
11.35
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
22
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multipair > Unshielded > 300 V
Xtra-Guard® 1
High Performance
300 V Unshielded, Multipair
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Part No.
Pairs
5282C
5283C
5286C
5289C
5289/12C
2
3
6
9
12
Operating Temperature
• 24, 22 AWG: Chart B (page 29)
• 20, 18 AWG: Chart A (page 29)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
18 AWG (0.81 mm2)
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
Nominal Diameter
Inch
mm
0.298
7.57
0.316
8.03
0.415
10.54
0.487
12.37
0.545
13.84
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
5032C
5033C
5036C
5039C
5039/12C
2
3
6
9
12
Nominal Diameter
Inch
mm
0.327
8.31
0.348
8.84
0.460
11.68
0.541
13.74
0.648
16.46
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
Materials
• S
tranded tinned copper
conductors
• Premium PVC insulation
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
23
Xtra-Guard 1 > Multipair > Foil Shield > 300 V
Xtra-Guard® 1
High Performance
300 V Foil Shield, Multipair
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.12 mm)
Insulation Thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Part No.
Pairs
5938
5939
5940
5941
5942
2
3
4
5
6
Operating Temperature
• 2
8, 26, 24, 22 AWG: Chart B
(page 29)
• 20, 18 AWG: Chart A (page 29)
• J
acket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
Nominal Diameter
Inch
mm
0.187
4.75
0.196
4.98
0.211
5.36
0.228
5.79
0.246
6.25
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
5690
5691
5692
5693
5694
2
3
4
5
6
Nominal Diameter
Inch
mm
0.200
5.08
0.210
5.33
0.227
5.77
0.246
6.25
0.265
6.73
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• A
luminum/polyester foil shield,
with 25% overlap and foil
facing inward
• T
inned copper drain wire sized
the same as cable conductors
• N
ylon ripcord
• P
remium PVC jacket
• UV resistant
Part No.
Pairs
5491C
5492C
5493C
5494C
5495C
5496C
5499C
5499/11C
5499/15C
5499/19C
5499/27C
1
2
3
4
5
6
9
11
15
19
27
Nominal Diameter
Inch
mm
0.160
4.06
0.216
5.49
0.228
5.79
0.247
6.27
0.268
6.81
0.290
7.37
0.336
8.53
0.361
9.17
0.405
10.29
0.433
11.00
0.516
13.11
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.32
0.81
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
24
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multipair > Foil Shield > 300 V
Xtra-Guard® 1
High Performance
300 V Foil Shield, Multipair
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Part No.
Pairs
5481C
5482C
5483C
5484C
5485C
5486C
5489C
5489/11C
5489/15C
5489/19C
5489/27C
1
2
3
4
5
6
9
11
15
19
27
Nominal Diameter
Inch
mm
0.172
4.37
0.236
5.99
0.249
6.32
0.271
6.88
0.295
7.49
0.320
8.13
0.372
9.45
0.400
10.16
0.451
11.46
0.483
12.27
0.619
15.72
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart B
(page 29)
• 20, 18 AWG: Chart A (page 29)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• S
tranded tinned copper
conductors
• Premium PVC insulation
• Aluminum/polyester foil shield,
with 25% overlap and foil
facing inward
• Tinned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• Premium PVC jacket
• UV resistant
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
5452C
5453C
5456C
5459C
5459/12C
5459/19C
2
3
6
9
12
19
Nominal Diameter
Inch
mm
0.302
7.67
0.320
8.13
0.419
10.64
0.491
12.47
0.549
13.94
0.689
17.50
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
5373C
5376C
3
6
Nominal Diameter
Inch
mm
0.352
8.94
0.464
11.79
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
25
Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multipair
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.12 mm)
Insulation Thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Part No.
Pairs
5943
5944
5945
5946
5947
2
3
4
5
6
Operating Temperature
• –30°C
to +80°C (AWM)
• –30°C
to +105°C (CM)
Conductor Color Coding
• 28,
26, 24, 22 AWG: Chart B
(page 29)
• 20,
18 AWG: Chart A (page 29)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• Stranded
tinned copper
conductors
• Premium
PVC insulation
• Supra-Shield
foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon
ripcord
• P
remium PVC jacket
• UV resistant
Nominal Diameter
Inch
mm
0.211
5.36
0.220
5.59
0.235
5.97
0.252
6.40
0.270
6.86
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
5695
5696
5697
5698
5699
2
3
4
5
6
Nominal Diameter
Inch
mm
0.224
5.69
0.234
5.94
0.251
6.38
0.270
6.86
0.289
7.34
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
5271C
5272C
5273C
5274C
5275C
5276C
5279C
5279/11C
5279/15C
5279/19C
5279/27C
5279/51C
1
2
3
4
5
6
9
11
15
19
27
51
Nominal Diameter
Inch
mm
0.184
4.67
0.240
6.10
0.252
6.40
0.271
6.88
0.292
7.42
0.314
7.98
0.360
9.14
0.385
9.78
0.429
10.90
0.457
11.61
0.540
13.72
0.739
18.77
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-221:
General-purpose,
cross-linked polyolefin (indoor)
• FIT-321:
Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
26
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multipair
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2464 VW-1
CSA CMG FT4
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart B
(page 29)
• 20, 18 AWG: Chart A (page 29)
• Jacket Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Supra-Shield foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium PVC jacket
• UV resistant
Part No.
Pairs
5121C
5122C
5123C
5124C
5125C
5126C
5129C
5129/11C
5129/15C
5129/19C
5129/27C
1
2
3
4
5
6
9
11
15
19
27
Nominal Diameter
Inch
mm
0.196
4.98
0.260
6.60
0.273
6.93
0.295
7.49
0.319
8.10
0.344
8.74
0.396
10.06
0.424
10.77
0.475
12.07
0.507
12.88
0.649
16.48
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
5292C
5293C
5296C
5299C
5299/19C
2
3
6
9
19
Nominal Diameter
Inch
mm
0.326
8.28
0.344
8.74
0.443
11.25
0.515
13.08
0.719
18.26
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
5132C
5133C
5136C
5139C
5139/27C
2
3
6
9
27
Nominal Diameter
Inch
mm
0.355
9.02
0.376
9.55
0.488
12.40
0.611
15.52
1.004
25.50
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.083
2.11
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
27
Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V
Xtra-Guard® 1
High Performance
300 V Supra-Shield® Foil/Braid, Multipair
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
UL CM
UL AWM 2343 VW-1
CSA CMG FT4
Part No.
Pairs
5330C
5331C
5332C
5333C
5334C
5335C
5336C
5
7
12
15
19
27
37
Operating Temperature
• –30°C
to +80°C (AWM)
• –30°C
to +105°C (CM)
Conductor Color Coding
• Chart
B (page 29)
• Jacket
Colors
• Put-ups: slate
• Bulk: nine colors available
(page 2, minimums
may apply)
Materials
• Stranded
tinned copper
conductors
• Premium
PVC insulation
• Supra-Shield
foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon
ripcord
• P
remium PVC jacket
• UV resistant
Availability
100 ft (30.5 m)
500 ft (152 m)
1000 ft (305 m)
Bulk, cut to length
Nominal Diameter
Inch
mm
0.354
8.99
0.376
9.55
0.458
11.63
0.491
12.47
0.519
13.18
0.602
15.29
0.669
16.99
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
5340/2C
5340C
5341C
5342C
5344C
5345C
5346C
2
5
7
12
19
27
37
Nominal Diameter
Inch
mm
0.322
8.18
0.381
9.68
0.406
10.31
0.499
12.67
0.569
14.45
0.669
16.99
0.738
18.75
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
5350/4C
5350C
5351C
5351/9C
5353C
5354C
5355C
4
5
7
9
15
19
27
Nominal Diameter
Inch
mm
0.388
9.86
0.416
10.57
0.446
11.33
0.505
12.83
0.597
15.16
0.634
16.10
0.749
19.02
Jacket Thickness
Inch
mm
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
0.063
1.60
FIT® Tubing Recommendations
• FIT-221:
General-purpose,
cross-linked polyolefin (indoor)
• FIT-321:
Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
28
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Conductor Color Coding
Multipair Cables
Chart A
Pair No. Color Combination
1
2
3
4
5
6
7
8
9
10
11
12
13
Black + Red
Black + White
Black + Green
Black + Blue
Black + Brown
Black + Yellow
Black + Orange
Red + Green
Red + White
Red + Blue
Red + Yellow
Red + Brown
Red + Orange
Pair No. Color Combination
14
15
16
17
18
19
20
21
22
23
24
25
26
Pair No. Color Combination
Green + Blue
Green + White
Green + Brown
Green + Orange
Green + Yellow
White + Blue
White + Brown
White + Orange
White + Yellow
Blue + Brown
Blue + Orange
Blue + Yellow
Brown + Orange
27
28
29
30
31
32
33
34
35
36
37
38
39
Brown + Yellow
Violet + Red
Violet + White
Violet + Green
Violet + Blue
Violet + Brown
Violet + Yellow
Violet + Orange
Violet + Slate
Violet + Black
Slate + Red
Slate + White
Slate + Green
Pair No. Color Combination
40
41
42
43
44
45
46
47
48
49
50
51
Slate + Blue
Slate + Brown
Slate + Yellow
Slate + Orange
Slate + Black
White/Black + Red
White/Black + Green
White/Black + Blue
White/Black + Brown
White/Black + Yellow
White/Black + Orange
White/Black + Violet
Chart B
Pair No. Color Combination
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
White + Black
White + Brown
White + Red
White + Orange
White + Yellow
White + Green
White + Blue
White + Violet
White + Slate
Black + Brown
Black + Red
Black + Orange
Black + Yellow
Black + Green
Black + Blue
Black + Violet
Black + Slate
Brown + Red
Brown + Orange
Brown + Yellow
Brown + Green
Brown + Blue
Brown + Violet
Brown + Slate
Red + Orange
Red + Yellow
Red + Green
Red + Blue
Red + Violet
Red + Slate
Orange + Yellow
Orange + Green
Orange + Blue
Orange + Violet
Pair No. Color Combination
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Orange + Slate
Yellow + Green
Yellow + Blue
Yellow + Violet
Yellow + Slate
Green + Blue
Green + Violet
Green + Slate
Blue + Violet
Blue + Slate
Violet + Slate
White/Black + Black
White/Black + Brown
White/Black + Red
White/Black + Orange
White/Black + Yellow
White/Black + Green
White/Black + Blue
White/Black + Violet
White/Black + Slate
White/Brown + Black
White/Brown + Brown
White/Brown + Red
White/Brown + Orange
White/Brown + Yellow
White/Brown + Green
White/Brown + Blue
White/Brown + Violet
White/Brown + Slate
White/Red + Black
White/Red + Brown
White/Red + Red
White/Red + Orange
White/Red + Yellow
Pair No. Color Combination
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
White/Red + Green
White/Red + Blue
White/Red + Violet
White/Red + Slate
White/Orange + Black
White/Orange + Brown
White/Orange + Red
White/Orange + Orange
White/Orange + Yellow
White/Orange + Green
White/Orange + Blue
White/Orange + Violet
White/Orange + Slate
White/Yellow + Black
White/Yellow + Brown
White/Yellow + Red
White/Yellow + Orange
White/Yellow + Yellow
White/Yellow + Green
White/Yellow + Blue
White/Yellow + Violet
White/Yellow + Slate
White/Green + Black
White/Green + Brown
White/Green + Red
White/Green + Orange
White/Green + Yellow
White/Green + Green
White/Green + Blue
White/Green + Violet
White/Green + Slate
White/Blue + Black
White/Blue + Brown
White/Blue + Red
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
29
Conductor Color Coding
Multiconductor Cables
Chart D
No. 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
30
Base 1st 2nd
3rd
Color StripeStripeStripe
Black
Red
White
Green
Orange
Blue
Brown
Yellow
Violet
Slate
Pink
Tan
Red
Red
Red
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Green
Yellow
Black
Black
Red
Green
Yellow
Blue
Brown
Orange
Slate
Violet
Black
Black
Black
Black
Black
Black
Black
Black
Black
Red
Red
Green
Yellow
Blue
Brown
Orange
Slate
Violet
Black
Black
No. 35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Base 1st 2nd
3rd
Color StripeStripeStripe
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Red
Red
Red
Red
Red
Green
Green
Green
Green
Green
Green
Blue
Blue
Blue
Blue
Blue
Blue
Brown
Brown
Brown
Brown
Brown
Brown
Violet
Violet
Violet
Black
Black
Black
Black
Black
Black
Black
Black
Red
Green
Blue
Brown
Violet
Black
Red
Green
Blue
Brown
Violet
Black
Red
Green
Blue
Brown
Violet
Black
Red
Green
Blue
Brown
Violet
Red
Green
Blue
Red
Red
Red
Red
Red
Red
Red
Green
Green
Yellow
Blue
Brown
Orange
Slate
Violet
Yellow
No. 69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Base 1st 2nd
3rd
Color StripeStripeStripe
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Green
Green
Green
Green
Green
Yellow
Yellow
Yellow
Yellow
Yellow
Blue
Blue
Blue
Blue
Brown
Brown
Brown
Orange
Orange
Slate
Black
Black
Black
Black
Black
Black
Black
Green
Green
Green
Green
Green
Blue
Brown
Orange
Slate
Violet
Blue
Brown
Orange
Slate
Violet
Brown
Orange
Slate
Violet
Orange
Slate
Violet
Slate
Violet
Violet
Green
Yellow
Blue
Brown
Orange
Slate
Violet
Yellow
Blue
Brown
Orange
Slate
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Conductor Color Coding
Multiconductor Cables
Chart E
No. 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Base 1st 2nd
3rd
Color StripeStripeStripe
Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Slate
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Slate
Black
Black
Black
Black
Black
Black
Black
Black
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Red
Orange
Yellow
Green
Blue
Violet
Slate
Red
Orange
Yellow
Green
Blue
Violet
Slate
No. 35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Base 1st 2nd
3rd
Color StripeStripeStripe
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Red
Orange
Red
Yellow
Red
Green
Red
Blue
Red
Violet
Red
Slate
Orange Yellow
Orange Green
Orange Blue
Orange Violet
Orange Slate
Yellow Green
Yellow Blue
Yellow Violet
Yellow Slate
Green Blue
Green Violet
Green Slate
Blue
Violet
Blue
Slate
Violet Slate
Black Brown
Black Brown
Black Brown
Black Brown
Black Brown
Black Brown
Black Brown
Black Red
Black Red
Black Red
Black Red
Black Red
Black Orange
Red
Orange
Yellow
Green
Blue
Violet
Slate
Yellow
Green
Blue
Violet
Slate
Yellow
No. 69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Base 1st 2nd
3rd
Color StripeStripeStripe
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Alpha Wire | www.alphawire.com | 1-800-52 ALPHA
Specifications subject to change. For complete specifications and availability, visit www.alphawire.com.
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Orange Green
Orange Blue
Orange Violet
Orange Slate
Yellow Green
Yellow Blue
Yellow Violet
Yellow Slate
Green Blue
Green Violet
Green Slate
Blue
Violet
Blue
Slate
Violet Slate
Red
Orange
Red
Yellow
Red
Green
Red
Blue
Red
Violet
Red
Slate
Orange Yellow
Orange Green
Orange Blue
Orange Violet
Orange Slate
Yellow Green
Yellow Blue
Yellow Violet
Yellow Slate
Green Blue
Green Violet
Green
Slate
31
The cables you trust.
The service you deserve.
Every application is critical
and cable failure is not an
option when the safety of your
equipment and personnel is
paramount. Specify Xtra-Guard 1
cable for extreme environments
and crucial applications, since
the integrity of your system is
only as robust as the products
you use.
GLOBAL HEADQUARTERS
711 Lidgerwood Avenue
Elizabeth, NJ 07207-0711 USA
Toll Free: 1-800-52 ALPHA
Tel: 1-908-925-8000
Fax: 1-908-925-5411
E-mail: [email protected]
Superior availability
Alpha offers Xtra-Guard 1
cable from stock in most sizes
and constructions, in small
quantities, so you can order
them when you need them.
Our products are available
for same-day shipment,
eliminating long lead times.
EUROPE
Alpha Wire International
Saxon House
1 Downside | Sunbury-on-Thames
Middlesex | United Kingdom | TW16 6RT
Tel: +44-(0)-800-288-8809
Fax: +44-(0)-800-288-8810
E-mail: [email protected]
©2012 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications.
Service and support,
second-to-none
Selecting the correct cable
is essential to overall system
reliability, performance, and
safety. So we make it easy for
you to select the right Alpha
product for your specific
application. Our online
resources include a wire and
cable selection guide, technical
information, full product
catalog, and a distributor
locator to make it easy to
select and get the cable,
wire, and wire management
accessories you need. Just visit
www.alphawire.com!
ASIA PACIFIC
Alpha Wire
Silver Center | Room 1708
North Shanxi Road 1388
Shanghai | China | 200060
Tel: +86-21-61498201/61498205
Fax: +86-21-61498001
E-mail: [email protected]
Lit. No. XG1-Bro-1206
Supersedes: New