Xtra-Guard® 1 Performance Cable Xtra-Guard 1 Cable Setting the standard in tough PVC cable Alpha Wire’s Xtra-Guard cable brings performance and reliability to the biggest challenges in the toughest environments. No matter what extremes your application faces, you’ll find an Xtra-Guard cable that excels in meeting your requirements. Years of abuse in some of the harshest environments have proven Xtra-Guard means peace of mind. With its premium PVC insulation and jacket, Xtra-Guard 1 cable strips cleanly and routes easily. It’s available in multiconductor and multipair configurations with 300 V and 600 V ratings. Features • C olor-coded, tinned copper conductors • P remium-grade PVC insulation and jacket for easier cable routing in small spaces • U nshielded, foil shielded, or Supra-Shield® foil/braid • 105°C temperature rating • U L VW-1, UL 1685, and CSA FT-4 flammability rating • NFPA 79 compliant • N ylon ripcord for easy jacket stripping • W ide range of cable configurations and lengths in stock, ready to ship same day 2 • N o minimum order quantity on lengths of 100’, 500’, and 1000’ • Samples of any product can be shipped next day free of charge SLATE BEIGE WHITE RED BLACK BLUE GREEN YELLOW ORANGE Applications • EIA RS-232 interface • High technology applications in controlled environments • Medical electronics • Point-of-sale equipment • Computer peripherals • Industrial process controls Xtra-Guard cables are available in a range of long-lasting colors for fast, easy identification, for safety reasons, and for matching the color of your system. FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard shielding options Alpha Wire offers Xtra-Guard 1 cables in three shielding options to handle virtually any electrical environment. Unshielded Unshielded cables provide the smallest cable diameter for use in low-noise controlled environments. Foil shielded Foil-shielded cables use a sturdy aluminum/polyester shield for moderate EMI needs, especially at lower frequencies. A tinned copper drain wire makes grounding the cable easy. Foil shields allow lighter weights and smaller cables. Supra-Shield® Alpha’s exclusive Supra-Shield cables combine a triple-layer aluminum/polyester/aluminum foil with a tinned copper braid shield with tight 70% coverage. Supra-Shield offers exceptional EMI performance and flexibility to protect against noise and maintain overall system integrity. The combination of foil and braid offers better shielding effectiveness than either approach alone against both low- and highfrequency noise. There’s an Xtra-Guard cable for any application hazard Xtra-Guard 1 High performance in a tough PVC jacket Xtra-Guard 2 Added abrasion resistance to withstand mechanical abuse Xtra-Guard 3 Direct burial—no conduit needed Xtra-Guard 4 Advanced temperature and chemical performance Xtra-Guard 5 Maximum chemical and temperature performance Xtra-Guard Flex Continuous flex applications Xtra-Guard Industrial Ethernet Cat 5e that’s beyond factory tough 70% Tinned Copper Braid Easy-To-Terminate, Continuous Contact Drain Wire Triple-Laminate Foil with 25% Overlap Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 3 Xtra-Guard 1 > Multiconductor > Unshielded > 300 V Xtra-Guard® 1 High performance 300 V Unshielded, Multiconductor 28 AWG (0.09 mm2) Stranding: 7/36 (7 x 0.127 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Part Number Conductors 5920 5921 5922 5923 5924 5925 2 3 4 6 7 8 Nominal Diameter Inch mm 0.138 3.51 0.144 3.66 0.153 3.89 0.174 4.42 0.174 4.42 0.185 4.70 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Operating Temperature 26 AWG (0.14 mm2) • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 2 8, 26, 24, 22 AWG: Chart E (page 31) • 20, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5666 5667 5668 5669 5670 5671 5672 5673 2 3 4 6 7 8 10 15 Materials Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) • S tranded tinned copper conductors • Premium PVC insulation • Nylon ripcord • Premium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 4 Nominal Diameter Inch mm 0.146 3.71 0.152 3.86 0.162 4.11 0.186 4.72 0.186 4.72 0.198 5.03 0.224 5.69 0.248 6.30 Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5012C 5013C 5014C 5016C 5018C 5020C 5020/15C 5020/20C 5020/25C 5020/30C 5020/40C 5020/50C 2 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.156 3.96 0.163 4.14 0.175 4.45 0.201 5.11 0.215 5.46 0.244 6.20 0.271 6.88 0.300 7.62 0.332 8.43 0.350 8.89 0.390 9.91 0.429 10.90 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multiconductor > Unshielded > 300 V Xtra-Guard® 1 High Performance 300 V Unshielded, Multiconductor 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 2 8, 26, 24, 22 AWG: Chart E (page 31) • 20, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • Premium PVC insulation • Nylon ripcord • Premium PVC jacket • UV resistant Availability Part Number Conductors 5002C 5003C 5004C 5006C 5008C 5010C 5010/15C 5010/20C 5010/25C 5010/30C 5010/40C 5010/50C 5010/60C 2 3 4 6 8 10 15 20 25 30 40 50 60 Nominal Diameter Inch mm 0.168 4.27 0.176 4.47 0.189 4.80 0.219 5.56 0.235 5.97 0.268 6.81 0.299 7.59 0.331 8.41 0.368 9.35 0.389 9.88 0.434 11.02 0.478 12.14 0.518 13.16 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Part Number Conductors 5052C 5053C 5054C 5056C 5058C 5060C 5060/15C 5060/20C 5060/25C 5060/30C 5060/40C 5060/50C 2 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.208 5.28 0.219 5.56 0.238 6.05 0.280 7.11 0.302 7.67 0.348 8.84 0.391 9.93 0.437 11.10 0.488 12.40 0.517 13.13 0.622 15.80 0.684 17.37 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 5 Xtra-Guard 1 > Multiconductor > Unshielded > 300 V Xtra-Guard® 1 High Performance 300 V Unshielded, Multiconductor 18 AWG (0.81 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 2 8, 26, 24, 22 AWG: Chart E (page 31) • 2 0, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • P remium PVC insulation • Nylon ripcord • P remium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations Part Number Conductors 5062/1C* 5062C 5063/1C* 5063C 5064C 5066C 5068C 5070C 5070/15C 5070/20C 5070/25C 5070/30C 5070/40C 5070/50C 5070/60C 2 2 3 3 4 6 8 10 15 20 25 30 40 50 60 Nominal Diameter Inch mm 0.226 5.74 0.226 5.74 0.238 6.05 0.238 6.05 0.259 6.58 0.307 7.80 0.332 8.43 0.384 9.75 0.433 11.00 0.484 12.29 0.542 13.77 0.617 15.67 0.688 17.48 0.758 19.25 0.881 22.38 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 0.083 2.11 *Conductors color-coded per international standards: brown, blue, green/yellow. 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.016 (0.41 mm) Part Number Conductors 5072/1C* 5072C 5073/1C* 2 2 3 5073C 5074C 5076C 5078C 5080C 5080/15C 5080/20C 5080/25C 5080/30C 5080/40C 5080/50C 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.250 6.35 0.250 6.35 0.264 6.71 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.264 0.288 0.343 0.372 0.432 0.488 0.547 0.656 0.694 0.775 0.917 0.032 0.032 0.032 0.032 0.032 0.032 0.053 0.053 0.053 0.083 0.083 6.71 7.32 8.71 9.45 10.97 12.40 13.89 16.66 17.63 19.69 23.29 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 0.81 2.11 2.11 *Conductors color-coded per international standards: brown, blue, green/yellow. • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 6 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multiconductor > Unshielded > 300 V Xtra-Guard® 1 High Performance 300 V Unshielded, Multiconductor 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2343 VW-1 CSA CMG FT4 Part Number Conductors 5201C 5202C 5203C 5204C 5206C 7 12 15 19 37 Operating Temperature • Chart E (page 31) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • Premium PVC insulation • Nylon ripcord • Premium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 22 AWG (0.35 mm2) • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding Nominal Diameter Inch mm 0.263 6.68 0.313 7.95 0.333 8.46 0.350 8.89 0.438 11.13 Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5210/2C 5211C 5212C 5213C 5214C 5214/25C 5215C 5216C 2 7 12 15 19 25 27 37 Nominal Diameter Inch mm 0.230 5.84 0.281 7.14 0.338 8.59 0.361 9.17 0.380 9.65 0.430 10.92 0.438 11.13 0.480 12.19 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5220/2C 5220C 5221C 5222C 5223C 5224C 5224/25C 5225C 5226C 2 5 7 12 15 19 25 27 37 Nominal Diameter Inch mm 0.246 6.25 0.288 7.32 0.305 7.75 0.371 9.42 0.398 10.11 0.420 10.67 0.478 12.14 0.487 12.37 0.536 13.61 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 7 Xtra-Guard 1 > Multiconductor > Unshielded > 600 V Xtra-Guard® 1 High Performance 600 V Unshielded, Multiconductor 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) UL CM UL AWM 2501 VW-1 UL MTW CSA AWM I/II A/B FT4 Part Number Conductors 5402 5404 5405 5409 5409/19 2 4 5 9 19 Conductor Color Coding • Chart E (page 31) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Operating Temperature • –30°C to +105°C • –30°C to +90°C (Dry MTW) • –30°C to +60°C (Wet MTW) Nominal Diameter Inch mm 0.318 8.08 0.358 9.09 0.385 9.78 0.473 12.01 0.601 15.27 Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.032 (0.81 mm) Part Number Conductors 5413 5414 5419 5419/12 5419/15 5419/19 5419/25 3 4 9 12 15 19 25 Nominal Diameter Inch mm 0.350 8.89 0.377 9.58 0.503 12.78 0.554 14.07 0.601 15.27 0.641 16.28 0.742 18.85 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 18 AWG (0.81 mm2) Materials • S tranded tinned copper conductors • P remium PVC insulation • Nylon ripcord • P remium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Part Number Conductors 5422 5423 5424 5425 5427 5429 5429/15 5429/19 5429/25 2 3 4 5 7 9 15 19 25 Nominal Diameter Inch mm 0.352 8.94 0.369 9.37 0.399 10.13 0.432 10.97 0.466 11.84 0.535 13.59 0.643 16.33 0.686 17.42 0.796 20.22 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 8 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multiconductor > Unshielded > 600 V Xtra-Guard® 1 High Performance 600 V Unshielded, Multiconductor 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.032 (0.81 mm) UL CM UL AWM 2501 VW-1 UL MTW CSA AWM I/II A/B FT4 Part Number Conductors 5434 5435 5437 5439 5439/12 5439/15 5439/19 5439/25 4 5 7 9 12 15 19 25 Nominal Diameter Inch mm 0.428 10.87 0.464 11.79 0.502 12.75 0.579 14.71 0.641 16.28 0.698 17.73 0.746 18.95 0.908 23.06 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 0.083 2.11 Operating Temperature • –30°C to +105°C • –30°C to +90°C (Dry MTW) • –30°C to +60°C (Wet MTW) Conductor Color Coding • Chart E (page 31) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • Premium PVC insulation • Nylon ripcord • Premium PVC jacket • UV resistant 14 AWG (2.08 mm2) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Part Number Conductors 5442 5443 5444 5445 5447 5449 5449/12 5449/15 5449/25 2 3 4 5 7 9 12 15 25 Nominal Diameter Inch mm 0.406 10.31 0.428 10.87 0.464 11.79 0.505 12.83 0.547 13.89 0.634 16.10 0.703 17.86 0.767 19.48 0.998 25.35 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 9 Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V Xtra-Guard® 1 High Performance 300 V Foil Shielded, Multiconductor 28 AWG (0.09 mm2) Stranding: 7/36 (7 x 0.127 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Part Number Conductors 5926 5927 5928 5929 5930 5931 2 3 4 6 7 8 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 2 8, 26, 24, 22 AWG: Chart E (page 31) • 20, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • P remium PVC insulation • A luminum/polyester foil shield, with 25% overlap and foil facing inward • T inned copper drain wire sized the same as cable conductors • Nylon ripcord • P remium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 10 Nominal Diameter Inch mm 0.142 3.61 0.148 3.76 0.157 3.99 0.178 4.52 0.178 4.52 0.189 4.80 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 26 AWG (0.14 mm2) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5674 5675 5676 5677 5678 5679 5680 5681 2 3 4 6 7 8 10 15 Nominal Diameter Inch mm 0.150 3.81 0.156 3.96 0.166 4.22 0.190 4.83 0.190 4.83 0.202 5.13 0.228 5.79 0.252 6.40 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5092C 5093C 5094C 5096C 5098C 5100C 5100/15C 5100/20C 5100/25C 5100/30C 5100/40C 5100/50C 5100/60C 5100/70C 2 3 4 6 8 10 15 20 25 30 40 50 60 70 Nominal Diameter Inch mm 0.160 4.06 0.167 4.24 0.179 4.55 0.205 5.21 0.219 5.56 0.248 6.30 0.275 6.99 0.304 7.72 0.336 8.53 0.354 8.99 0.394 10.01 0.433 11.00 0.468 11.89 0.505 12.83 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V Xtra-Guard® 1 High Performance 300 V Foil Shielded, Multiconductor 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 28, 26, 24, 22 AWG: Chart E (page 31) • 20, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • Stranded tinned copper conductors • Premium PVC insulation • Aluminum/polyester foil shield, with 25% overlap and foil facing inward • Tinned copper drain wire sized the same as cable conductors • Nylon ripcord • Premium PVC jacket • UV resistant Part Number Conductors 5192C 5193C 5194C 5196C 5198C 5199/10C 5199/15C 5199/20C 5199/25C 5199/30C 5199/40C 5199/50C 5199/60C 5199/70C 2 3 4 6 8 10 15 20 25 30 40 50 60 70 Nominal Diameter Inch mm 0.172 4.37 0.180 4.57 0.193 4.90 0.223 5.66 0.239 6.07 0.272 6.91 0.303 7.70 0.335 8.51 0.372 9.45 0.393 9.98 0.438 11.13 0.482 12.24 0.522 13.26 0.606 15.39 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Part Number Conductors 5462C 5463C 5464C 5466C 5468C 5470C 5470/15C 5470/20C 5470/25C 5470/30C 5470/40C 5470/50C 2 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.212 5.38 0.223 5.66 0.242 6.15 0.284 7.21 0.306 7.77 0.352 8.94 0.395 10.03 0.441 11.20 0.492 12.50 0.521 13.23 0.626 15.90 0.688 17.48 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • FIT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 11 Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V Xtra-Guard® 1 High Performance 300 V Foil Shielded, Multiconductor 18 AWG (0.81 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 2 8, 26, 24, 22 AWG: Chart E (page 31) • 20, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • P remium PVC insulation • A luminum/polyester foil shield, with 25% overlap and foil facing inward • T inned copper drain wire sized the same as cable conductors • Nylon ripcord • P remium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length Part Number Conductors 5382C 5382/1C* 5383C 5383/1C* 5384C 5386C 5388C 5390C 5390/15C 5390/20C 5390/25C 5390/30C 5390/40C 5390/50C 5390/60C 2 2 3 3 4 6 8 10 15 20 25 30 40 50 60 Nominal Diameter Inch mm 0.230 5.84 0.230 5.84 0.242 6.15 0.242 6.15 0.263 6.68 0.311 7.90 0.336 8.53 0.388 9.86 0.437 11.10 0.488 12.40 0.588 14.94 0.621 15.77 0.692 17.58 0.762 19.35 0.885 22.48 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 0.053 1.35 0.083 2.11 *Conductors color-coded per international standards: brown, blue, green/yellow. 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.016 (0.41 mm) Part Number Conductors 5362C 5362/1C* 5363C 5363/1C* 5364C 5366C 5368C 5370C 5370/15C 5370/20C 5370/25C 5370/30C 5370/40C 2 2 3 3 4 6 8 10 15 20 25 30 40 Nominal Diameter Inch mm 0.254 6.45 0.254 6.45 0.268 6.81 0.268 6.81 0.292 7.42 0.347 8.81 0.376 9.55 0.436 11.07 0.492 12.50 0.593 15.06 0.660 16.76 0.698 17.73 0.779 19.79 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 0.083 2.11 *Conductors color-coded per international standards: brown, blue, green/yellow. FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 12 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multiconductor > Foil Shielded > 300 V Xtra-Guard® 1 High Performance 300 V Foil Shielded, Multiconductor 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2343 VW-1 CSA CMG FT4 Part Number Conductors 5599/3C 5599/5C 5599/7C 5599/12C 5599/15C 5599/19C 5599/27C 3 5 7 12 15 19 27 Nominal Diameter Inch mm 0.229 5.82 0.254 6.45 0.267 6.78 0.317 8.05 0.337 8.56 0.354 8.99 0.405 10.29 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • Chart E (page 31) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • Stranded tinned copper conductors • Premium PVC insulation • Aluminum/polyester foil shield, with 25% overlap and foil facing inward • Tinned copper drain wire sized the same as cable conductors • Nylon ripcord • Premium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5580/2C 5580C 5581C 5582C 5583C 5584C 5586C 2 5 7 12 15 19 37 Nominal Diameter Inch mm 0.234 5.94 0.270 6.86 0.285 7.24 0.342 8.69 0.365 9.27 0.384 9.75 0.484 12.29 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5560/2C 5560C 5561C 5562C 5563C 5564C 2 5 7 12 15 19 Nominal Diameter Inch mm 0.250 6.35 0.292 7.42 0.309 7.85 0.375 9.53 0.402 10.21 0.424 10.77 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 FIT® Tubing Recommendations • FIT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 13 Xtra-Guard 1 > Multiconductor > Foil Shielded > 600 V Xtra-Guard® 1 High Performance 600 V Foil Shielded, Multiconductor 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) UL AWM 2501 VW-1 CSA AWM I/II A/B FT4 UL MTW Part Number Conductors 5410/2 5410/3 5410/4 5410/5 5410/9 5410/12 2 3 4 5 9 12 Operating Temperature • Chart E (page 31) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) • –30°C to +105°C • –30°C to +90°C (Dry MTW) • –30°C to +60°C (Wet MTW) Conductor Color Coding Nominal Diameter Inch mm 0.322 8.18 0.337 8.56 0.362 9.19 0.389 9.88 0.477 12.12 0.525 13.34 Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.032 (0.81 mm) Part Number Conductors 5420/3 5420/4 5420/5 5420/7 5420/9 5420/12 3 4 5 7 9 12 Materials Nominal Diameter Inch mm 0.354 8.99 0.381 9.68 0.411 10.44 0.442 11.23 0.507 12.88 0.558 14.17 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 18 AWG (0.81 mm2) • S tranded tinned copper conductors • P remium PVC insulation • A luminum/polyester foil shield, with 25% overlap and foil facing inward • T inned copper drain wire sized the same as cable conductors • Nylon ripcord • P remium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Part Number Conductors 5430/2 5430/3 5430/4 5430/5 5430/7 5430/9 5430/12 5430/15 5430/19 5430/25 2 3 4 5 7 9 12 15 19 25 Nominal Diameter Inch mm 0.356 9.04 0.373 9.47 0.403 10.24 0.436 11.07 0.470 11.94 0.539 13.69 0.595 15.11 0.647 16.43 0.690 17.53 0.800 20.32 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 14 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multiconductor > Foil Shielded > 600 V Xtra-Guard® 1 High Performance 600 V Foil Shielded, Multiconductor 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.032 (0.81 mm) UL AWM 2501 VW-1 CSA AWM I/II A/B FT4 UL MTW Operating Temperature Part Number Conductors 5440/2 5440/3 5440/4 5440/5 5440/7 5440/9 5440/12 5440/15 2 3 4 5 7 9 12 15 • –30°C to +105°C • –30°C to +90°C (Dry MTW) • –30°C to +60°C (Wet MTW) Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 14 AWG (2.08 mm2) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Conductor Color Coding • Chart E (page 31) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Nominal Diameter Inch mm 0.380 9.65 0.399 10.13 0.432 10.97 0.468 11.89 0.506 12.85 0.583 14.81 0.645 16.38 0.702 17.83 Part Number Conductors 5450/2 5450/3 5450/4 5450/5 5450/7 5450/12 2 3 4 5 7 12 Nominal Diameter Inch mm 0.410 10.41 0.432 10.97 0.468 11.89 0.509 12.93 0.551 14.00 0.707 17.96 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 Materials • S tranded tinned copper conductors • Premium PVC insulation • Aluminum/polyester foil shield, with 25% overlap and foil facing inward • Tinned copper drain wire sized the same as cable conductors • Nylon ripcord • Premium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 15 Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V Xtra-Guard® 1 High Performance 300 V Supra-Shield® Foil/Braid, Multiconductor 28 AWG (0.09 mm2) Stranding: 7/36 (7 x 0.127 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Part Number Conductors 5932 5933 5934 5935 5936 5937 2 3 4 6 7 8 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 2 8, 26, 24, 22 AWG: Chart E (page 31) • 20, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • P remium PVC insulation • Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • Nylon ripcord • P remium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length Nominal Diameter Inch mm 0.166 4.22 0.172 4.37 0.181 4.60 0.202 5.13 0.202 5.13 0.213 5.41 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 26 AWG (0.14 mm2) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5682 5683 5684 5685 5686 5687 5688 5689 2 3 4 6 7 8 10 15 Nominal Diameter Inch mm 0.174 4.42 0.180 4.57 0.190 4.83 0.214 5.44 0.214 5.44 0.226 5.74 0.252 6.40 0.276 7.01 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5112C 5113C 5114C 5116C 5118C 5120C 5120/15C 5120/20C 5120/25C 5120/30C 5120/40C 5120/50C 2 3 4 6 8 10 15 20 25 30 40 50 Nominal Diameter Inch mm 0.184 4.67 0.191 4.85 0.203 5.16 0.229 5.82 0.243 6.17 0.272 6.91 0.299 7.59 0.328 8.33 0.360 9.14 0.378 9.60 0.418 10.62 0.457 11.61 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 16 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Cable > Xtra-Guard > Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V Xtra-Guard® 1 High Performance 300 V Supra-Shield® Foil/Braid, Multiconductor 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 28, 26, 24, 22 AWG: Chart E (page 31) • 2 0, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • Stranded tinned copper conductors • Premium PVC insulation • Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • Nylon ripcord • Premium PVC jacket • UV resistant Part Number Conductors 5102C 5103C 5104C 5106C 5108C 5110C 5110/15C 5110/20C 5110/25C 5110/30C 5110/40C 5110/50C 5110/60C 5110/70C 5110/80C 2 3 4 6 8 10 15 20 25 30 40 50 60 70 80 Nominal Diameter Inch mm 0.196 4.98 0.204 5.18 0.217 5.51 0.247 6.27 0.263 6.68 0.296 7.52 0.327 8.31 0.359 9.12 0.396 10.06 0.417 10.59 0.462 11.73 0.506 12.85 0.588 14.94 0.630 16.00 0.665 16.89 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Part Number Conductors 5152C 5153C 5154C 5156C 5158C 5160C 5160/15C 5160/20C 5160/25C 5160/30C 5160/40C 5160/50C 5160/60C 2 3 4 6 8 10 15 20 25 30 40 50 60 Nominal Diameter Inch mm 0.236 5.99 0.247 6.27 0.266 6.76 0.308 7.82 0.330 8.38 0.376 9.55 0.419 10.64 0.465 11.81 0.516 13.11 0.545 13.84 0.656 16.66 0.718 18.24 0.774 19.66 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • FIT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 17 Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V Xtra-Guard® 1 High Performance 300 V Supra-Shield® Foil/Braid, Multiconductor 18 AWG (0.81 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 2 8, 26, 24, 22 AWG: Chart E (page 31) • 20, 18, 16 AWG: Chart D (page 30) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • P remium PVC insulation • S upra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • Nylon ripcord • P remium PVC jacket • UV resistant Part Number Conductors 5162/1C* 5162C 5163/1C* 5163C 5164C 5166C 5168C 5170C 5170/15C 5170/20C 5170/25C 5170/30C 5170/40C 2 2 3 3 4 6 8 10 15 20 25 30 40 Nominal Diameter Inch mm 0.254 6.45 0.254 6.45 0.266 6.76 0.266 6.76 0.287 7.29 0.335 8.51 0.360 9.14 0.412 10.46 0.461 11.71 0.512 13.00 0.612 15.54 0.651 16.54 0.722 18.34 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 0.053 1.35 *Conductors color-coded per international standards: brown, blue, green/yellow. 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.016 (0.41 mm) Part Number Conductors 5172/1C* 5172C 5173/1C* 5173C 5174C 5176C 5178C 5180C 5180/15C 5180/20C 5180/25C 2 2 3 3 4 6 8 10 15 20 25 Nominal Diameter Inch mm 0.278 7.06 0.278 7.06 0.292 7.42 0.292 7.42 0.316 8.03 0.371 9.42 0.400 10.16 0.460 11.68 0.516 13.11 0.617 15.67 0.690 17.53 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 *Conductors color-coded per international standards: brown, blue, green/yellow. Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 18 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 300 V Xtra-Guard® 1 High Performance 300 V Supra-Shield® Foil/Braid, Multiconductor 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2343 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • Chart E (page 31) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • Stranded tinned copper conductors • Premium PVC insulation • Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • Nylon ripcord • Premium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length Part Number Conductors 5300C 5301C 5302C 5303C 5304C 5305C 5306C 5307C 5 7 12 15 19 27 37 48 Nominal Diameter Inch mm 0.278 7.06 0.291 7.39 0.341 8.66 0.361 9.17 0.378 9.60 0.429 10.90 0.466 11.84 0.517 13.13 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5310C 5311C 5312C 5313C 5314C 5316C 5318C 5 7 12 15 19 37 60 Nominal Diameter Inch mm 0.294 7.47 0.309 7.85 0.366 9.30 0.389 9.88 0.408 10.36 0.508 12.90 0.608 15.44 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Part Number Conductors 5320/4C 5320C 5321C 5322C 5323C 5324C 5325C 5326C 4 5 7 12 15 19 27 37 Nominal Diameter Inch mm 0.299 7.59 0.316 8.03 0.333 8.46 0.399 10.13 0.426 10.82 0.448 11.38 0.515 13.08 0.564 14.33 Jacket Thickness Inch Mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 FIT® Tubing Recommendations • FIT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 19 Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 600 V Xtra-Guard® 1 High Performance 600 V Supra-Shield® Foil/Braid, Multiconductor 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) UL AWM 2501 VW-1 CSA AWM I/II A/B FT4 UL MTW Part Number Conductors 5504 5507 5509/12 4 7 12 Conductor Color Coding • C hart E (page 31) • J acket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • P remium PVC insulation • S upra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • N ylon ripcord • P remium PVC jacket • UV resistant Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Stranding: 10/30 (10 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Operating Temperature • –30°C to +105°C • –30°C to +90°C (Dry MTW) • –30°C to +60°C (Wet MTW) Nominal Diameter Inch mm 0.386 9.80 0.442 11.23 0.549 13.94 Part Number Conductors 5514 5517 5519 5519/12 5519/19 4 7 9 12 19 Nominal Diameter Inch mm 0.405 10.29 0.466 11.84 0.531 13.49 0.582 14.78 0.675 17.15 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 18 AWG (0.81 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Part Number Conductors 5522 5523 5524 5525 5527 5529 5529/12 5529/15 5529/19 2 3 4 5 7 9 12 15 19 Nominal Diameter Inch mm 0.380 9.65 0.397 10.08 0.427 10.85 0.460 11.68 0.494 12.55 0.563 14.30 0.619 15.72 0.677 17.20 0.760 19.30 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 20 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multiconductor > Supra-Shield Foil/Braid > 600 V Xtra-Guard® 1 High Performance 600 V Supra-Shield® Foil/Braid, Multiconductor 16 AWG (1.23 mm2) Stranding: 19/0.0117 (19 x 0.29 mm) Insulation thickness: 0.032 (0.81 mm) UL AWM 2501 VW-1 CSA AWM I/II A/B FT4 UL MTW Operating Temperature • –30°C to +105°C • –30°C to +90°C (Dry MTW) • –30°C to +60°C (Wet MTW) Part Number Conductors 5532 5533 5534 5535 5537 5539 5539/12 5539/15 5539/19 2 3 4 5 7 9 12 15 19 Materials • S tranded tinned copper conductors • Premium PVC insulation • Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • Nylon ripcord • Premium PVC jacket • UV resistant Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 14 AWG (2.08 mm2) Stranding: 41/30 (41 x 0.25 mm) Insulation thickness: 0.032 (0.81 mm) Conductor Color Coding • C hart E (page 31) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Nominal Diameter Inch mm 0.404 10.26 0.423 10.74 0.456 11.58 0.492 12.50 0.530 13.46 0.607 15.42 0.675 17.15 0.772 19.61 0.820 20.83 Part Number Conductors 5542 5543 5544 5547 5549 5549/12 5549/15 2 3 4 7 9 12 15 Nominal Diameter Inch mm 0.434 11.02 0.456 11.58 0.492 12.50 0.575 14.61 0.668 16.97 0.777 19.74 0.841 21.36 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.083 2.11 0.083 2.11 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 21 Xtra-Guard 1 > Multipair > Unshielded > 300 V Xtra-Guard® 1 High Performance 300 V Unshielded, Multipair 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Part No. Pairs 5261C 5262C 5263C 5264C 5265C 5266C 5269C 5269/11C 5269/15C 5269/27C 5269/77C 1 2 3 4 5 6 9 11 15 27 77 Nominal Diameter Inch mm 0.156 3.96 0.212 5.38 0.224 5.69 0.243 6.17 0.264 6.71 0.286 7.26 0.332 8.43 0.357 9.07 0.401 10.19 0.512 13.00 0.904 22.96 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.083 0.81 Conductor Color Coding • 24, 22 AWG: Chart B (page 29) • 2 0, 18 AWG: Chart A (page 29) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • P remium PVC insulation • Nylon ripcord • P remium PVC jacket • UV resistant 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5021C 5022C 5023C 5024C 5025C 5026C 5029/15C 1 2 3 4 5 6 15 Nominal Diameter Inch mm 0.168 4.27 0.232 5.89 0.245 6.22 0.267 6.78 0.291 7.39 0.316 8.03 0.447 11.35 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 22 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multipair > Unshielded > 300 V Xtra-Guard® 1 High Performance 300 V Unshielded, Multipair 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Part No. Pairs 5282C 5283C 5286C 5289C 5289/12C 2 3 6 9 12 Operating Temperature • 24, 22 AWG: Chart B (page 29) • 20, 18 AWG: Chart A (page 29) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 18 AWG (0.81 mm2) • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding Nominal Diameter Inch mm 0.298 7.57 0.316 8.03 0.415 10.54 0.487 12.37 0.545 13.84 Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs 5032C 5033C 5036C 5039C 5039/12C 2 3 6 9 12 Nominal Diameter Inch mm 0.327 8.31 0.348 8.84 0.460 11.68 0.541 13.74 0.648 16.46 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.053 1.35 Materials • S tranded tinned copper conductors • Premium PVC insulation • Nylon ripcord • Premium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 23 Xtra-Guard 1 > Multipair > Foil Shield > 300 V Xtra-Guard® 1 High Performance 300 V Foil Shield, Multipair 28 AWG (0.09 mm2) Stranding: 7/36 (7 x 0.12 mm) Insulation Thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Part No. Pairs 5938 5939 5940 5941 5942 2 3 4 5 6 Operating Temperature • 2 8, 26, 24, 22 AWG: Chart B (page 29) • 20, 18 AWG: Chart A (page 29) • J acket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 26 AWG (0.14 mm2) • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding Nominal Diameter Inch mm 0.187 4.75 0.196 4.98 0.211 5.36 0.228 5.79 0.246 6.25 Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5690 5691 5692 5693 5694 2 3 4 5 6 Nominal Diameter Inch mm 0.200 5.08 0.210 5.33 0.227 5.77 0.246 6.25 0.265 6.73 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Materials • S tranded tinned copper conductors • P remium PVC insulation • A luminum/polyester foil shield, with 25% overlap and foil facing inward • T inned copper drain wire sized the same as cable conductors • N ylon ripcord • P remium PVC jacket • UV resistant Part No. Pairs 5491C 5492C 5493C 5494C 5495C 5496C 5499C 5499/11C 5499/15C 5499/19C 5499/27C 1 2 3 4 5 6 9 11 15 19 27 Nominal Diameter Inch mm 0.160 4.06 0.216 5.49 0.228 5.79 0.247 6.27 0.268 6.81 0.290 7.37 0.336 8.53 0.361 9.17 0.405 10.29 0.433 11.00 0.516 13.11 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.32 0.81 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • F IT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 24 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multipair > Foil Shield > 300 V Xtra-Guard® 1 High Performance 300 V Foil Shield, Multipair 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Part No. Pairs 5481C 5482C 5483C 5484C 5485C 5486C 5489C 5489/11C 5489/15C 5489/19C 5489/27C 1 2 3 4 5 6 9 11 15 19 27 Nominal Diameter Inch mm 0.172 4.37 0.236 5.99 0.249 6.32 0.271 6.88 0.295 7.49 0.320 8.13 0.372 9.45 0.400 10.16 0.451 11.46 0.483 12.27 0.619 15.72 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 Conductor Color Coding • 2 8, 26, 24, 22 AWG: Chart B (page 29) • 20, 18 AWG: Chart A (page 29) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • S tranded tinned copper conductors • Premium PVC insulation • Aluminum/polyester foil shield, with 25% overlap and foil facing inward • Tinned copper drain wire sized the same as cable conductors • Nylon ripcord • Premium PVC jacket • UV resistant 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs 5452C 5453C 5456C 5459C 5459/12C 5459/19C 2 3 6 9 12 19 Nominal Diameter Inch mm 0.302 7.67 0.320 8.13 0.419 10.64 0.491 12.47 0.549 13.94 0.689 17.50 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 18 AWG (0.81 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs 5373C 5376C 3 6 Nominal Diameter Inch mm 0.352 8.94 0.464 11.79 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • F IT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 25 Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V Xtra-Guard® 1 High Performance 300 V Supra-Shield® Foil/Braid, Multipair 28 AWG (0.09 mm2) Stranding: 7/36 (7 x 0.12 mm) Insulation Thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Part No. Pairs 5943 5944 5945 5946 5947 2 3 4 5 6 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 28, 26, 24, 22 AWG: Chart B (page 29) • 20, 18 AWG: Chart A (page 29) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • Stranded tinned copper conductors • Premium PVC insulation • Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • Nylon ripcord • P remium PVC jacket • UV resistant Nominal Diameter Inch mm 0.211 5.36 0.220 5.59 0.235 5.97 0.252 6.40 0.270 6.86 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 26 AWG (0.14 mm2) Stranding: 7/34 (7 x 0.16 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5695 5696 5697 5698 5699 2 3 4 5 6 Nominal Diameter Inch mm 0.224 5.69 0.234 5.94 0.251 6.38 0.270 6.86 0.289 7.34 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5271C 5272C 5273C 5274C 5275C 5276C 5279C 5279/11C 5279/15C 5279/19C 5279/27C 5279/51C 1 2 3 4 5 6 9 11 15 19 27 51 Nominal Diameter Inch mm 0.184 4.67 0.240 6.10 0.252 6.40 0.271 6.88 0.292 7.42 0.314 7.98 0.360 9.14 0.385 9.78 0.429 10.90 0.457 11.61 0.540 13.72 0.739 18.77 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • FIT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 26 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V Xtra-Guard® 1 High Performance 300 V Supra-Shield® Foil/Braid, Multipair 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2464 VW-1 CSA CMG FT4 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • 28, 26, 24, 22 AWG: Chart B (page 29) • 20, 18 AWG: Chart A (page 29) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • Stranded tinned copper conductors • Premium PVC insulation • Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • Nylon ripcord • Premium PVC jacket • UV resistant Part No. Pairs 5121C 5122C 5123C 5124C 5125C 5126C 5129C 5129/11C 5129/15C 5129/19C 5129/27C 1 2 3 4 5 6 9 11 15 19 27 Nominal Diameter Inch mm 0.196 4.98 0.260 6.60 0.273 6.93 0.295 7.49 0.319 8.10 0.344 8.74 0.396 10.06 0.424 10.77 0.475 12.07 0.507 12.88 0.649 16.48 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs 5292C 5293C 5296C 5299C 5299/19C 2 3 6 9 19 Nominal Diameter Inch mm 0.326 8.28 0.344 8.74 0.443 11.25 0.515 13.08 0.719 18.26 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 18 AWG (0.81 mm2) Stranding: 16/30 (16 x 0.25 mm) Insulation thickness: 0.016 (0.41 mm) Part No. Pairs 5132C 5133C 5136C 5139C 5139/27C 2 3 6 9 27 Nominal Diameter Inch mm 0.355 9.02 0.376 9.55 0.488 12.40 0.611 15.52 1.004 25.50 Jacket Thickness Inch mm 0.032 0.81 0.032 0.81 0.032 0.81 0.053 1.35 0.083 2.11 Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length FIT® Tubing Recommendations • FIT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 27 Xtra-Guard 1 > Multipair > Supra-Shield Foil/Braid > 300 V Xtra-Guard® 1 High Performance 300 V Supra-Shield® Foil/Braid, Multipair 24 AWG (0.23 mm2) Stranding: 7/32 (7 x 0.20 mm) Insulation thickness: 0.010 (0.25 mm) UL CM UL AWM 2343 VW-1 CSA CMG FT4 Part No. Pairs 5330C 5331C 5332C 5333C 5334C 5335C 5336C 5 7 12 15 19 27 37 Operating Temperature • –30°C to +80°C (AWM) • –30°C to +105°C (CM) Conductor Color Coding • Chart B (page 29) • Jacket Colors • Put-ups: slate • Bulk: nine colors available (page 2, minimums may apply) Materials • Stranded tinned copper conductors • Premium PVC insulation • Supra-Shield foil + braid shield: Aluminum/polyester/aluminum foil with 25% overlap min. Tinned copper drain wire sized the same as conductors Tinned copper braid, 70% coverage min. • Nylon ripcord • P remium PVC jacket • UV resistant Availability 100 ft (30.5 m) 500 ft (152 m) 1000 ft (305 m) Bulk, cut to length Nominal Diameter Inch mm 0.354 8.99 0.376 9.55 0.458 11.63 0.491 12.47 0.519 13.18 0.602 15.29 0.669 16.99 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 22 AWG (0.35 mm2) Stranding: 7/30 (7 x 0.25 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5340/2C 5340C 5341C 5342C 5344C 5345C 5346C 2 5 7 12 19 27 37 Nominal Diameter Inch mm 0.322 8.18 0.381 9.68 0.406 10.31 0.499 12.67 0.569 14.45 0.669 16.99 0.738 18.75 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 20 AWG (0.56 mm2) Stranding: 7/28 (7 x 0.32 mm) Insulation thickness: 0.010 (0.25 mm) Part No. Pairs 5350/4C 5350C 5351C 5351/9C 5353C 5354C 5355C 4 5 7 9 15 19 27 Nominal Diameter Inch mm 0.388 9.86 0.416 10.57 0.446 11.33 0.505 12.83 0.597 15.16 0.634 16.10 0.749 19.02 Jacket Thickness Inch mm 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 0.063 1.60 FIT® Tubing Recommendations • FIT-221: General-purpose, cross-linked polyolefin (indoor) • FIT-321: Medium-wall, adhesive-lined, cross-linked polyolefin (outdoor) 28 Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Conductor Color Coding Multipair Cables Chart A Pair No. Color Combination 1 2 3 4 5 6 7 8 9 10 11 12 13 Black + Red Black + White Black + Green Black + Blue Black + Brown Black + Yellow Black + Orange Red + Green Red + White Red + Blue Red + Yellow Red + Brown Red + Orange Pair No. Color Combination 14 15 16 17 18 19 20 21 22 23 24 25 26 Pair No. Color Combination Green + Blue Green + White Green + Brown Green + Orange Green + Yellow White + Blue White + Brown White + Orange White + Yellow Blue + Brown Blue + Orange Blue + Yellow Brown + Orange 27 28 29 30 31 32 33 34 35 36 37 38 39 Brown + Yellow Violet + Red Violet + White Violet + Green Violet + Blue Violet + Brown Violet + Yellow Violet + Orange Violet + Slate Violet + Black Slate + Red Slate + White Slate + Green Pair No. Color Combination 40 41 42 43 44 45 46 47 48 49 50 51 Slate + Blue Slate + Brown Slate + Yellow Slate + Orange Slate + Black White/Black + Red White/Black + Green White/Black + Blue White/Black + Brown White/Black + Yellow White/Black + Orange White/Black + Violet Chart B Pair No. Color Combination 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 White + Black White + Brown White + Red White + Orange White + Yellow White + Green White + Blue White + Violet White + Slate Black + Brown Black + Red Black + Orange Black + Yellow Black + Green Black + Blue Black + Violet Black + Slate Brown + Red Brown + Orange Brown + Yellow Brown + Green Brown + Blue Brown + Violet Brown + Slate Red + Orange Red + Yellow Red + Green Red + Blue Red + Violet Red + Slate Orange + Yellow Orange + Green Orange + Blue Orange + Violet Pair No. Color Combination 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 Orange + Slate Yellow + Green Yellow + Blue Yellow + Violet Yellow + Slate Green + Blue Green + Violet Green + Slate Blue + Violet Blue + Slate Violet + Slate White/Black + Black White/Black + Brown White/Black + Red White/Black + Orange White/Black + Yellow White/Black + Green White/Black + Blue White/Black + Violet White/Black + Slate White/Brown + Black White/Brown + Brown White/Brown + Red White/Brown + Orange White/Brown + Yellow White/Brown + Green White/Brown + Blue White/Brown + Violet White/Brown + Slate White/Red + Black White/Red + Brown White/Red + Red White/Red + Orange White/Red + Yellow Pair No. Color Combination 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 White/Red + Green White/Red + Blue White/Red + Violet White/Red + Slate White/Orange + Black White/Orange + Brown White/Orange + Red White/Orange + Orange White/Orange + Yellow White/Orange + Green White/Orange + Blue White/Orange + Violet White/Orange + Slate White/Yellow + Black White/Yellow + Brown White/Yellow + Red White/Yellow + Orange White/Yellow + Yellow White/Yellow + Green White/Yellow + Blue White/Yellow + Violet White/Yellow + Slate White/Green + Black White/Green + Brown White/Green + Red White/Green + Orange White/Green + Yellow White/Green + Green White/Green + Blue White/Green + Violet White/Green + Slate White/Blue + Black White/Blue + Brown White/Blue + Red Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 29 Conductor Color Coding Multiconductor Cables Chart D No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 30 Base 1st 2nd 3rd Color StripeStripeStripe Black Red White Green Orange Blue Brown Yellow Violet Slate Pink Tan Red Red Red White White White White White White White White White White White White White White White White White White White Green Yellow Black Black Red Green Yellow Blue Brown Orange Slate Violet Black Black Black Black Black Black Black Black Black Red Red Green Yellow Blue Brown Orange Slate Violet Black Black No. 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 Base 1st 2nd 3rd Color StripeStripeStripe White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White Red Red Red Red Red Green Green Green Green Green Green Blue Blue Blue Blue Blue Blue Brown Brown Brown Brown Brown Brown Violet Violet Violet Black Black Black Black Black Black Black Black Red Green Blue Brown Violet Black Red Green Blue Brown Violet Black Red Green Blue Brown Violet Black Red Green Blue Brown Violet Red Green Blue Red Red Red Red Red Red Red Green Green Yellow Blue Brown Orange Slate Violet Yellow No. 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Base 1st 2nd 3rd Color StripeStripeStripe White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Black Red Red Red Red Red Red Red Red Red Red Red Red Green Green Green Green Green Yellow Yellow Yellow Yellow Yellow Blue Blue Blue Blue Brown Brown Brown Orange Orange Slate Black Black Black Black Black Black Black Green Green Green Green Green Blue Brown Orange Slate Violet Blue Brown Orange Slate Violet Brown Orange Slate Violet Orange Slate Violet Slate Violet Violet Green Yellow Blue Brown Orange Slate Violet Yellow Blue Brown Orange Slate Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Conductor Color Coding Multiconductor Cables Chart E No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 Base 1st 2nd 3rd Color StripeStripeStripe Black Brown Red Orange Yellow Green Blue Violet Slate White White White White White White White White White White White White White White White White White White White White White White White White White Black Brown Red Orange Yellow Green Blue Violet Slate Black Black Black Black Black Black Black Black Brown Brown Brown Brown Brown Brown Brown Brown Red Orange Yellow Green Blue Violet Slate Red Orange Yellow Green Blue Violet Slate No. 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 Base 1st 2nd 3rd Color StripeStripeStripe White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White Red Orange Red Yellow Red Green Red Blue Red Violet Red Slate Orange Yellow Orange Green Orange Blue Orange Violet Orange Slate Yellow Green Yellow Blue Yellow Violet Yellow Slate Green Blue Green Violet Green Slate Blue Violet Blue Slate Violet Slate Black Brown Black Brown Black Brown Black Brown Black Brown Black Brown Black Brown Black Red Black Red Black Red Black Red Black Red Black Orange Red Orange Yellow Green Blue Violet Slate Yellow Green Blue Violet Slate Yellow No. 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Base 1st 2nd 3rd Color StripeStripeStripe White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White White Alpha Wire | www.alphawire.com | 1-800-52 ALPHA Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. Black Black Black Black Black Black Black Black Black Black Black Black Black Black Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Brown Orange Green Orange Blue Orange Violet Orange Slate Yellow Green Yellow Blue Yellow Violet Yellow Slate Green Blue Green Violet Green Slate Blue Violet Blue Slate Violet Slate Red Orange Red Yellow Red Green Red Blue Red Violet Red Slate Orange Yellow Orange Green Orange Blue Orange Violet Orange Slate Yellow Green Yellow Blue Yellow Violet Yellow Slate Green Blue Green Violet Green Slate 31 The cables you trust. The service you deserve. Every application is critical and cable failure is not an option when the safety of your equipment and personnel is paramount. Specify Xtra-Guard 1 cable for extreme environments and crucial applications, since the integrity of your system is only as robust as the products you use. GLOBAL HEADQUARTERS 711 Lidgerwood Avenue Elizabeth, NJ 07207-0711 USA Toll Free: 1-800-52 ALPHA Tel: 1-908-925-8000 Fax: 1-908-925-5411 E-mail: [email protected] Superior availability Alpha offers Xtra-Guard 1 cable from stock in most sizes and constructions, in small quantities, so you can order them when you need them. Our products are available for same-day shipment, eliminating long lead times. EUROPE Alpha Wire International Saxon House 1 Downside | Sunbury-on-Thames Middlesex | United Kingdom | TW16 6RT Tel: +44-(0)-800-288-8809 Fax: +44-(0)-800-288-8810 E-mail: [email protected] ©2012 Alpha Wire. All rights reserved. Specifications subject to change. Consult Alpha Wire for latest specifications. Service and support, second-to-none Selecting the correct cable is essential to overall system reliability, performance, and safety. So we make it easy for you to select the right Alpha product for your specific application. Our online resources include a wire and cable selection guide, technical information, full product catalog, and a distributor locator to make it easy to select and get the cable, wire, and wire management accessories you need. Just visit www.alphawire.com! ASIA PACIFIC Alpha Wire Silver Center | Room 1708 North Shanxi Road 1388 Shanghai | China | 200060 Tel: +86-21-61498201/61498205 Fax: +86-21-61498001 E-mail: [email protected] Lit. No. XG1-Bro-1206 Supersedes: New