Download Brochure

Pro-Tekt™
European Cable System
Technical Catalog
High-Performance Cables for
Demanding Applications
E
very cable application is important, and durable, long-lasting equipment
requires rugged reliability. Downtime is costly, and your reputation can’t
afford failure caused by cable that doesn’t live up to the demands of the
application. Built on our more than 80 years’ experience and reputation for
quality and reliability, Pro-Tekt™ cables are designed for the challenging
demands of your specific application.
Pro-Tekt Cable
The Tough, Durable Choice
Offering rugged, reliable
performance in demanding
applications, Pro-Tekt cables
feature a unique, premium-grade
PVC insulation and jacket that
makes routing of the cable easier
in small, tight spaces.
2
Application:
• Industrial process controls
• Point-of-sale equipment
• Computer peripherals
• Medical electronics
• High-technology controlled
environment
Cable > Pro-Tekt > Multiconductor > Unshielded > 300 V
Pro-Tekt™
High Performance
300 V Unshielded, Multiconductor
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.127 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Part Number
Conductors
B951021
B951031
B951041
B951061
B951071
B951081
2
3
4
6
7
8
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
• 2
8, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Materials
• S
tranded tinned
copper conductors
• Premium PVC insulation
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Operating Temperature
Conductor Color Coding
Nominal Diameter
Inch
mm
0.137
3.48
0.143
3.63
0.152
3.86
0.173
4.39
0.173
4.39
0.184
4.67
Part Number
Conductors
B952021
B952031
B952041
B952061
B952071
B952081
B952101
B952151
2
3
4
6
7
8
10
15
Nominal Diameter
Inch
mm
0.145
3.68
0.151
3.84
0.161
4.09
0.185
4.70
0.185
4.70
0.197
5.00
0.223
5.66
0.247
6.27
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
B953021
B953031
B953041
B953061
B953081
B953101
B953151
B953201
B953251
B953301
B953401
B953501
B953801
2
3
4
6
8
10
15
20
25
30
40
50
80
Nominal Diameter
Inch
mm
0.155
3.94
0.162
4.11
0.174
4.42
0.20
5.08
0.214
5.44
0.243
6.17
0.270
6.86
0.299
7.59
0.331
8.41
0.349
8.86
0.389
9.88
0.428
10.87
0.525
13.34
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
3
Cable > Pro-Tekt > Multiconductor > Unshielded > 300 V
Pro-Tekt™
High Performance
300 V Unshielded, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
Part Number
Conductors
B954021
B954031
B954041
B954061
B954081
B954101
B954151
B954201
B954251
B954301
B954401
B954501
B954601
2
3
4
6
8
10
15
20
25
30
40
50
60
• 2
8, 26, 24, 22 AWG: Chart E
• 2
0, 18, 16 AWG: Chart D
Availability
• 5
0, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
4
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Materials
• S
tranded tinned
copper conductors
• P
remium PVC insulation
• Nylon ripcord
• P
remium grey PVC jacket
• UV resistant
Nominal Diameter
Inch
mm
0.167
4.24
0.175
4.44
0.188
4.78
0.218
5.54
0.234
5.94
0.267
6.78
0.298
7.57
0.330
8.38
0.367
9.32
0.388
9.86
0.433
11.00
0.477
12.12
0.517
13.13
Part Number
Conductors
B955021
B955031
B955041
B955061
B955081
B955101
B955151
B955201
B955251
B955301
B955401
B955501
2
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.207
5.26
0.218
5.54
0.237
6.02
0.279
7.09
0.301
7.65
0.347
8.81
0.390
9.91
0.436
11.07
0.487
12.37
0.516
13.11
0.621
15.77
0.683
17.35
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
Cable > Pro-Tekt >Multiconductor > Unshielded > 300 V
Pro-Tekt™
High Performance
300 V Unshielded, Multiconductor
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Part Number
Conductors
B956021
B956021N*
B956031
B956031N
B956041
B956061
B956081
B956101
B956151
B956201
B956251
B956301
B956401
B956501
B956601
2
2
3
3
4
6
8
10
15
20
25
30
40
50
60
Nominal Diameter
Inch
mm
0.225
5.72
0.225
5.72
0.237
6.02
0.237
6.02
0.258
6.55
0.306
7.77
0.331
8.41
0.383
9.73
0.432
10.97
0.483
12.27
0.541
13.74
0.616
15.65
0.687
17.45
0.757
19.23
0.880
22.35
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
0.083
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
Materials
• S
tranded tinned
copper conductors
• Premium PVC insulation
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
B957021
B957021N
B957031
2
2
3
B957031N
B957041
B957061
B957081
B957101
B957151
B957201
B957251
B957301
B957401
B957501
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.249
6.32
0.249
6.32
0.263
6.68
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.263
0.287
0.342
0.371
0.431
0.487
0.546
0.655
0.693
0.774
0.916
0.032
0.032
0.032
0.032
0.032
0.032
0.053
0.053
0.053
0.083
0.083
6.68
7.29
8.69
9.42
10.95
12.37
13.87
16.64
17.60
19.66
23.27
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
0.81
2.11
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
5
Cable > Pro-Tekt > Multiconductor > Foil Shielded > 300 V
Pro-Tekt™
High Performance
300 V Foil Shielded, Multiconductor
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.127 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Part Number
Conductors
B951022
B951032
B951042
B951062
B951072
B951082
2
3
4
6
7
8
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• A
luminum/polyester foil shield,
with 25% overlap and foil
facing inward
• T
inned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• P
remium grey PVC jacket
• UV resistant
Availability
• 5
0, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
6
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Nominal Diameter
Inch
mm
0.141
3.58
0.147
3.73
0.156
3.96
0.177
4.50
0.177
4.50
0.188
4.78
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
B952022
B952032
B952042
B952062
B952072
B952082
B952102
B952152
2
3
4
6
7
8
10
15
Nominal Diameter
Inch
mm
0.149
3.78
0.155
3.94
0.165
4.19
0.189
4.80
0.189
4.80
0.201
5.11
0.227
5.77
0.251
6.38
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
B953022
B953032
B953042
B953062
B953082
B953102
B953152
B953202
B953252
B953302
B953402
B953502
B953602
B953702
2
3
4
6
8
10
15
20
25
30
40
50
60
70
Nominal Diameter
Inch
mm
0.159
4.04
0.166
4.22
0.178
4.52
0.204
5.18
0.218
5.54
0.247
6.27
0.274
6.96
0.303
7.70
0.335
8.51
0.353
8.97
0.393
9.98
0.432
10.97
0.467
11.86
0.504
12.80
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
Cable > Pro-Tekt > Multiconductor > Foil Shielded > 300 V
Pro-Tekt™
High Performance
300 V Foil Shielded, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Aluminum/polyester foil shield,
with 25% overlap and foil
facing inward
• Tinned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Part Number
Conductors
B954022
B954032
B954042
B954062
B954082
B954102
B954152
B954202
B954252
B954302
B954402
B954502
B954602
B954702
2
3
4
6
8
10
15
20
25
30
40
50
60
70
Nominal Diameter
Inch
mm
0.171
4.34
0.179
4.55
0.192
4.88
0.222
5.64
0.238
6.05
0.271
6.88
0.302
7.67
0.334
8.48
0.371
9.42
0.392
9.96
0.437
11.10
0.481
12.22
0.521
13.23
0.605
15.37
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
B955022
B955032
B955042
B955062
B955082
B955102
B955152
B955202
B955252
B955302
B955402
B955502
2
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.211
5.36
0.222
5.64
0.241
6.12
0.283
7.19
0.305
7.75
0.351
8.92
0.394
10.01
0.440
11.18
0.491
12.47
0.520
13.21
0.625
15.88
0.687
17.45
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
7
Cable > Pro-Tekt > Multiconductor > Foil Shielded > 300 V
Pro-Tekt™
High Performance
300 V Foil Shielded, Multiconductor
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• A
luminum/polyester foil shield,
with 25% overlap and foil
facing inward
• T
inned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• P
remium grey PVC jacket
• UV resistant
Availability
• 5
0, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
8
Part Number
Conductors
B956022
B956022N*
B956032
B956032N*
B956042
B956062
B956082
B956102
B956152
B956202
B956252
B956302
B956402
B956502
B956602
2
2
3
3
4
6
8
10
15
20
25
30
40
50
60
Nominal Diameter
Inch
mm
0.229
5.82
0.229
5.82
0.241
6.12
0.241
6.12
0.262
6.65
0.310
7.87
0.335
8.51
0.387
9.83
0.436
11.07
0.487
12.37
0.587
14.91
0.620
15.75
0.691
17.55
0.761
19.33
0.884
22.45
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
0.053
1.35
0.083
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
B957022
B957022N*
B957032
B957032N*
B957042
B957062
B957082
B957102
B957152
B957202
B957252
B957302
B957402
2
2
3
3
4
6
8
10
15
20
25
30
40
Nominal Diameter
Inch
mm
0.253
6.43
0.253
6.43
0.267
6.78
0.267
6.78
0.291
7.39
0.346
8.79
0.375
9.52
0.435
11.05
0.491
12.47
0.592
15.04
0.659
16.74
0.697
17.70
0.778
19.76
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
0.083
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
Cable > Pro-Tekt > Multiconductor > Braid Shield > 300 V
Pro-Tekt™
High Performance
300 V Braid Shield, Multiconductor
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.12 mm)
Insulation Thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Part Number
Conductors
B951023
B951033
B951043
B951063
B951073
B951083
2
3
4
6
7
8
Nominal Diameter
Inch
mm
0.159
4.04
0.165
4.19
0.174
4.42
0.195
4.95
0.195
4.95
0.206
5.23
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.32 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
B952023
B952033
B952043
B952063
B952073
B952083
B952103
B952153
2
3
4
6
7
8
10
15
Nominal Diameter
Inch
mm
0.167
4.24
0.173
4.39
0.183
4.65
0.207
5.26
0.207
5.26
0.219
5.56
0.245
6.22
0.269
6.83
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.35 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
B953023
B953033
B953043
B953063
B953083
B953103
B953153
B953203
B953253
B953303
B953403
B953503
B953603
B953703
2
3
4
6
8
10
15
20
25
30
40
50
60
70
Nominal Diameter
Inch
mm
0.177
4.50
0.184
4.67
0.196
4.98
0.222
5.64
0.236
5.99
0.265
6.73
0.292
7.42
0.321
8.15
0.353
8.97
0.371
9.42
0.411
10.44
0.450
11.43
0.491
12.47
0.528
13.41
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
9
Cable > Pro-Tekt > Multiconductor > Braid Shield > 300 V
Pro-Tekt™
High Performance
300 V Braid Shield, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 5
0, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
10
Part Number
Conductors
B954023
B954033
B954043
B954063
B954083
B954103
B954153
B954203
B954253
B954303
B954403
B954503
B954603
B954703
2
3
4
6
8
10
15
20
25
30
40
50
60
70
Nominal Diameter
Inch
mm
0.189
4.80
0.197
5.00
0.210
5.33
0.240
6.10
0.256
6.50
0.289
7.34
0.320
8.13
0.352
8.94
0.389
9.88
0.410
10.41
0.455
11.56
0.505
12.83
0.587
14.91
0.629
15.98
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
B955023
B955033
B955043
B955063
B955083
B955103
B955153
B955203
B955253
B955303
B955403
B955503
2
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.229
5.82
0.240
6.10
0.259
6.58
0.301
7.65
0.323
8.20
0.369
9.37
0.412
10.46
0.458
11.63
0.515
13.08
0.544
13.82
0.649
16.48
0.718
18.24
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
Cable > Pro-Tekt > Multiconductor > Braid Shield > 300 V
Pro-Tekt™
High Performance
300 V Braid Shield, Multiconductor
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Part Number
Conductors
B956023
B956023N*
B956033
B956033N*
B956043
B956063
B956083
B956103
B956153
B956203
B956253
B956303
B956403
B956503
2
2
3
3
4
6
8
10
15
20
25
30
40
60
Nominal Diameter
Inch
mm
0.247
6.27
0.247
6.27
0.259
6.58
0.259
6.58
0.28
7.11
0.328
8.33
0.353
8.97
0.405
10.29
0.454
11.53
0.511
12.98
0.611
15.52
0.644
16.36
0.722
18.34
0.792
20.12
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
*Conductors color-coded per international standards: brown, blue, green/yellow.
16 AWG (1.23 mm2)
Stranding: 41/30 (41 x 0.25 mm)
Insulation thickness: 0.032 (0.81 mm)
Part Number
Conductors
B957023
B957023N*
B957033
B957033N*
B957043
B957063
B957083
B957103
B957153
B957203
B957253
B957303
B957403
2
2
3
3
4
6
8
10
15
20
25
30
40
Nominal Diameter
Inch
mm
0.271
6.88
0.271
6.88
0.285
7.24
0.285
7.24
0.309
7.85
0.364
9.25
0.393
9.98
0.453
11.51
0.515
13.08
0.616
15.65
0.690
17.53
0.728
18.49
0.809
20.55
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
0.083
2.11
*Conductors color-coded per international standards: brown, blue, green/yellow.
11
Cable > Pro-Tekt > Multiconductor > Supra-Shield Foil/Braid > 300 V
Pro-Tekt™
High Performance
300 V Foil/Braid, Multiconductor
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.127 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Part Number
Conductors
B951024
B951034
B951044
B951064
B951074
B951084
2
3
4
6
7
8
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• Foil
+ braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• P
remium grey PVC jacket
• UV resistant
Availability
• 5
0, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
12
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Nominal Diameter
Inch
mm
0.165
4.19
0.171
4.34
0.180
4.57
0.201
5.11
0.201
5.11
0.212
5.38
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
B952024
B952034
B952044
B952064
B952074
B952084
B952104
B952154
2
3
4
6
7
8
10
15
Nominal Diameter
Inch
mm
0.173
4.39
0.179
4.55
0.189
4.80
0.213
5.41
0.213
5.41
0.225
5.72
0.251
6.38
0.275
6.98
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Conductors
B953024
B953034
B953044
B953064
B953084
B953104
B953154
B953204
B953254
B953304
B953404
B953504
2
3
4
6
8
10
15
20
25
30
40
50
Nominal Diameter
Inch
mm
0.183
4.65
0.190
4.83
0.202
5.13
0.228
5.79
0.242
6.15
0.271
6.88
0.298
7.57
0.327
8.31
0.359
9.12
0.377
9.58
0.417
10.59
0.456
11.58
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
Cable > Pro-Tekt > Multiconductor > Supra-Shield Foil/Braid > 300 V
Pro-Tekt™
High Performance
300 V Foil/Braid, Multiconductor
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Part Number
Conductors
B954024
B954034
B954044
B954064
B954084
B954104
B954154
B954204
B954254
B954304
B954404
B954504
B954604
B954704
B954804
2
3
4
6
8
10
15
20
25
30
40
50
60
70
80
Nominal Diameter
Inch
mm
0.195
4.95
0.203
5.16
0.216
5.49
0.246
6.25
0.262
6.65
0.295
7.49
0.326
8.28
0.358
9.09
0.395
10.03
0.416
10.57
0.461
11.71
0.511
12.98
0.587
14.91
0.629
15.98
0.664
16.87
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
B955024
B955034
B955044
B955064
B955084
B955104
B955154
B955204
B955254
B955304
B955404
B955504
B955604
2
3
4
6
8
10
15
20
25
30
40
50
60
Nominal Diameter
Inch
mm
0.235
5.97
0.246
6.25
0.265
6.73
0.307
7.80
0.329
8.36
0.375
9.52
0.418
10.62
0.464
11.79
0.515
13.08
0.544
13.82
0.655
16.64
0.717
18.21
0.773
19.63
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
13
Cable > Pro-Tekt > Multiconductor > Supra-Shield Foil/Braid > 300 V
Pro-Tekt™
High Performance
300 V Foil/Braid, Multiconductor
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 2
8, 26, 24, 22 AWG: Chart E
• 20, 18, 16 AWG: Chart D
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• F
oil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• P
remium grey PVC jacket
• UV resistant
Availability
• 5
0, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
14
Part Number
Conductors
B956024
B956024N*
B956034
B956034N*
B956044
B956064
B956084
B956104
B956154
B956204
B956254
B956304
B956404
B956603
2
2
3
3
4
6
8
10
15
20
25
30
40
Nominal Diameter
Inch
mm
0.253
6.43
0.253
6.43
0.265
6.73
0.265
6.73
0.286
7.26
0.334
8.48
0.359
9.12
0.411
10.44
0.460
11.68
0.511
12.98
0.611
15.52
0.650
16.51
0.721
18.31
0.921
23.39
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
0.053
1.35
0.053
1.35
*Conductors color-coded per international standards: brown, blue, green/yellow.
16 AWG (1.23 mm2)
Stranding: 19/0.0117 (19 x 0.29 mm)
Insulation thickness: 0.016 (0.41 mm)
Part Number
Conductors
B957024
B957024N*
B957034
B957034N*
B957044
B957064
B957084
B957104
B957154
B957204
B957254
2
2
3
3
4
6
8
10
15
20
25
Nominal Diameter
Inch
mm
0.277
7.04
0.277
7.04
0.291
7.39
0.291
7.39
0.315
8.00
0.370
9.40
0.399
10.13
0.459
11.66
0.515
13.08
0.616
15.65
0.689
17.50
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
*Conductors color-coded per international standards: brown, blue, green/yellow.
Cable > Pro-Tekt > Multipair > Unshielded > 300 V
Pro-Tekt™
High Performance
300 V Unshielded, Multipair
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Part Number
Pairs
B963011
B963021
B963031
B963041
B963051
B963061
B963091
B963111
B963151
B963271
B963771
1
2
3
4
5
6
9
11
15
27
77
Materials
• S
tranded tinned copper
conductors
• Premium PVC insulation
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.083
0.81
22 AWG (0.35 mm2)
Conductor Color Coding
• 24, 22 AWG: Chart B
• 20, 18 AWG: Chart A
Nominal Diameter
Inch
mm
0.155
3.94
0.211
5.36
0.223
5.66
0.242
6.15
0.263
6.68
0.285
7.24
0.331
8.41
0.356
9.04
0.400
10.16
0.511
12.98
0.903
22.94
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
Part Number
Pairs
B964011
B964021
B964031
B964041
B964051
B964061
B964151
1
2
3
4
5
6
15
Nominal Diameter
Inch
mm
0.167
4.24
0.231
5.87
0.244
6.20
0.266
6.76
0.290
7.37
0.315
8.00
0.446
11.33
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
15
Cable > Pro-Tekt > Multipair > Unshielded > 300 V
Pro-Tekt™
High Performance
300 V Unshielded, Multipair
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation Thickness: 0.016 (0.41 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Part Number
Pairs
B965021
B965031
B965061
B965091
B965121
2
3
6
9
12
Conductor Color Coding
• 24, 22 AWG: Chart B
• 2
0, 18 AWG: Chart A
Materials
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• Nylon ripcord
• P
remium grey PVC jacket
• UV resistant
Availability
• 5
0, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
16
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation Thickness: 0.016 (0.41 mm)
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Nominal Diameter
Inch
mm
0.297
7.54
0.315
8.00
0.414
10.52
0.486
12.34
0.544
13.82
Part Number
Pairs
B966021
B966031
B966061
B966091
B966121
2
3
6
9
12
Nominal Diameter
Inch
mm
0.326
8.28
0.347
8.81
0.459
11.66
0.54
13.72
0.647
16.43
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.053
1.35
Cable > Pro-Tekt > Multipair > Foil Shield > 300 V
Pro-Tekt™
High Performance
300 V Foil Shield, Multipair
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.12 mm)
Insulation Thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Part No.
Pairs
B961022
B961032
B961042
B961052
B961062
2
3
4
5
6
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart B
• 20, 18 AWG: Chart A
Materials
• S
tranded tinned copper
conductors
• Premium PVC insulation
• Aluminum/polyester foil shield,
with 25% overlap and foil
facing inward
• Tinned copper drain wire sized
the same as cable conductors
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Nominal Diameter
Inch
mm
0.186
4.72
0.195
4.95
0.210
5.33
0.227
5.77
0.245
6.22
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
B962022
B962032
B962042
B962052
B962062
2
3
4
5
6
Nominal Diameter
Inch
mm
0.199
5.05
0.209
5.31
0.226
5.74
0.245
6.22
0.264
6.71
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
B963012
B963022
B963032
B963042
B963052
B963062
B963092
B963112
B963152
B963192
B963272
1
2
3
4
5
6
9
11
15
19
27
Nominal Diameter
Inch
mm
0.159
4.04
0.215
5.46
0.227
5.77
0.246
6.25
0.267
6.78
0.289
7.34
0.335
8.51
0.360
9.14
0.404
10.26
0.432
10.97
0.515
13.08
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.32
0.81
17
Cable > Pro-Tekt > Multipair > Foil Shield > 300 V
Pro-Tekt™
High Performance
300 V Foil Shield, Multipair
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Part No.
Pairs
B964012
B964022
B964032
B964042
B964052
B964062
B964092
B964112
B964152
B964192
B964272
1
2
3
4
5
6
9
11
15
19
27
Conductor Color Coding
• S
tranded tinned copper
conductors
• P
remium PVC insulation
• A
luminum/polyester foil shield,
with 25% overlap and foil
facing inward
• T
inned copper drain wire sized
the same as cable conductors
• N
ylon ripcord
• P
remium grey PVC jacket
• UV resistant
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
B965022
B965032
B965062
B965092
B965122
B965192
2
3
6
9
12
19
Pairs
• 5
0, 100, 500, 1000 m
B966032
B966062
3
6
18
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• F
IT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Nominal Diameter
Inch
mm
0.301
7.65
0.319
8.10
0.418
10.62
0.490
12.45
0.548
13.92
0.688
17.48
18 AWG (0.81 mm2)
Availability
FIT® Tubing Recommendations
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
20 AWG (0.56 mm2)
• 2
8, 26, 24, 22 AWG: Chart B
• 20, 18 AWG: Chart A
Materials
Nominal Diameter
Inch
mm
0.171
4.34
0.235
5.97
0.248
6.30
0.270
6.86
0.294
7.47
0.319
8.10
0.371
9.42
0.399
10.13
0.450
11.43
0.482
12.24
0.618
15.70
Nominal Diameter
Inch
mm
0.351
8.92
0.463
11.76
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
Cable > Pro-Tekt > Multipair > Braid Shield> 300 V
Pro-Tekt™
High Performance
300 V Braid Shield, Multipair
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.12 mm)
Insulation Thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Part No.
Pairs
B961023
B961033
B961043
B961053
B961063
2
3
4
5
6
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart B
• 20, 18 AWG: Chart A
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Nominal Diameter
Inch
mm
0.204
5.18
0.213
5.41
0.228
5.79
0.245
6.22
0.263
6.68
Part No.
Pairs
B962023
B962033
B962043
B962053
B962063
2
3
4
5
6
Nominal Diameter
Inch
mm
0.217
5.51
0.227
5.77
0.244
6.20
0.263
6.68
0.282
7.16
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
24 AWG (0.32 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
B963013
B963023
B963033
B963043
B963053
B963063
B963093
B963113
B963153
B963193
B963273
1
2
3
4
5
6
9
11
15
19
27
Nominal Diameter
Inch
mm
0.177
4.50
0.233
5.92
0.245
6.22
0.264
6.71
0.285
7.24
0.307
7.80
0.353
8.97
0.378
9.60
0.422
10.72
0.450
11.43
0.539
13.69
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
19
Cable > Pro-Tekt > Multipair > Braid Shield> 300 V
Pro-Tekt™
High Performance
300 V Braid Shield, Multipair
22 AWG (0.35 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Part No.
Pairs
B964013
B964023
B964033
B964043
B964053
B964063
B964093
B964113
B964153
B964193
B964273
1
2
3
4
5
6
9
11
15
19
27
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
• 28, 26, 24, 22 AWG: Chart B
• 20, 18 AWG: Chart A
• Stranded tinned copper
conductors
• Premium PVC insulation
• Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Part No.
Pairs
B965023
B965033
B965063
B965093
B965123
B965193
2
3
6
9
12
19
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
• 50, 100, 500, 1000 m
Part No.
Pairs
FIT® Tubing Recommendations
B966033
B966063
3
6
20
Nominal Diameter
Inch
mm
0.319
8.10
0.337
8.56
0.436
11.07
0.514
13.06
0.572
14.53
0.719
18.26
18 AWG (0.81 mm2)
Availability
• F
IT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
20 AWG (0.56 mm2)
Conductor Color Coding
Materials
Nominal Diameter
Inch
mm
0.189
4.80
0.253
6.43
0.266
6.76
0.288
7.32
0.312
7.92
0.337
8.56
0.389
9.88
0.417
10.59
0.474
12.04
0.506
12.85
0.642
16.31
Nominal Diameter
Inch
mm
0.369
9.37
0.487
12.37
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
Cable > Pro-Tekt > Multipair > Supra-Shield Foil/Braid > 300 V
Pro-Tekt™
High Performance
300 V Foil/Braid, Multipair
28 AWG (0.09 mm2)
Stranding: 7/36 (7 x 0.12 mm)
Insulation Thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C to +80°C (AWM)
• –30°C to +105°C (CM)
Conductor Color Coding
• 28, 26, 24, 22 AWG: Chart B
• 20, 18 AWG: Chart A
Materials
• Stranded tinned copper
conductors
• Premium PVC insulation
• Foil + braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon ripcord
• Premium grey PVC jacket
• UV resistant
Availability
• 50, 100, 500, 1000 m
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
Part No.
Pairs
B961024
B961034
B961044
B961054
B961064
2
3
4
5
6
Nominal Diameter
Inch
mm
0.210
5.33
0.219
5.56
0.234
5.94
0.251
6.38
0.269
6.83
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
26 AWG (0.14 mm2)
Stranding: 7/34 (7 x 0.16 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
B962024
B962034
B962044
B962054
B962064
2
3
4
5
6
Nominal Diameter
Inch
mm
0.210
5.33
0.219
5.56
0.234
5.94
0.251
6.38
0.269
6.83
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
24 AWG (0.23 mm2)
Stranding: 7/32 (7 x 0.20 mm)
Insulation thickness: 0.010 (0.25 mm)
Part No.
Pairs
B963014
B963024
B963034
B963044
B963054
B963064
B963094
B963114
B963154
B963194
B963274
B963514
1
2
3
4
5
6
9
11
15
19
27
51
Nominal Diameter
Inch
mm
0.183
4.65
0.239
6.07
0.251
6.38
0.270
6.86
0.291
7.39
0.313
7.95
0.359
9.12
0.384
9.75
0.428
10.87
0.456
11.58
0.539
13.69
0.738
18.75
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
21
Cable > Pro-Tekt > Multipair > Supra-Shield Foil/Braid > 300 V
Pro-Tekt™
High Performance
300 V Foil/Braid, Multipair
22 AWG (0.35 mm2)
Stranding: 7/30 (7 x 0.25 mm)
Insulation thickness: 0.010 (0.25 mm)
IEC EN 60332-1
IEC EN 60332-2
UL CM
UL AWM 2464 VW-1
Operating Temperature
• –30°C
to +80°C (AWM)
• –30°C
to +105°C (CM)
Part No.
Pairs
B964014
B964024
B964034
B964044
B964054
B964064
B964094
B964114
B964154
B964194
B964274
1
2
3
4
5
6
9
11
15
19
27
Conductor Color Coding
• 28,
26, 24, 22 AWG: Chart B
• 20,
18 AWG: Chart A
Materials
• Stranded
tinned copper
conductors
• Premium PVC insulation
• Foil
+ braid shield:
Aluminum/polyester/aluminum
foil with 25% overlap min.
Tinned copper drain wire sized
the same as conductors
Tinned copper braid, 70%
coverage min.
• Nylon
ripcord
• P
remium grey PVC jacket
• UV resistant
Availability
• 5
0, 100, 500, 1000 m
FIT® Tubing Recommendations
• FIT-221: General-purpose,
cross-linked polyolefin (indoor)
• FIT-321: Medium-wall,
adhesive-lined, cross-linked
polyolefin (outdoor)
22
Nominal Diameter
Inch
mm
0.195
4.95
0.259
6.58
0.272
6.91
0.294
7.47
0.318
8.08
0.343
8.71
0.395
10.03
0.423
10.74
0.474
12.04
0.506
12.85
0.648
16.46
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
20 AWG (0.56 mm2)
Stranding: 7/28 (7 x 0.32 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
B965024
B965034
B965064
B965094
B965194
2
3
6
9
19
Nominal Diameter
Inch
mm
0.325
8.25
0.343
8.71
0.442
11.23
0.514
13.06
0.718
18.24
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
18 AWG (0.81 mm2)
Stranding: 16/30 (16 x 0.25 mm)
Insulation thickness: 0.016 (0.41 mm)
Part No.
Pairs
B966024
B966034
B966064
B966094
B966274
2
3
6
9
27
Nominal Diameter
Inch
mm
0.354
8.99
0.375
9.52
0.487
12.37
0.610
15.49
1.007
25.58
Jacket Thickness
Inch
mm
0.032
0.81
0.032
0.81
0.032
0.81
0.053
1.35
0.083
2.11
Conductor Color Coding
Multipair Cables
Chart A
Pair
No.
Color
Combination
Pair
No.
Color
Combination
Pair
No.
Color
Combination
Pair
No.
Color
Combination
1
2
3
4
5
6
7
8
9
10
11
12
13
Black + Red
Black + White
Black + Green
Black + Blue
Black + Brown
Black + Yellow
Black + Orange
Red + Green
Red + White
Red + Blue
Red + Yellow
Red + Brown
Red + Orange
14
15
16
17
18
19
20
21
22
23
24
25
26
Green + Blue
Green + White
Green + Brown
Green + Orange
Green + Yellow
White + Blue
White + Brown
White + Orange
White + Yellow
Blue + Brown
Blue + Orange
Blue + Yellow
Brown + Orange
27
28
29
30
31
32
33
34
35
36
37
38
39
Brown + Yellow
Violet + Red
Violet + White
Violet + Green
Violet + Blue
Violet + Brown
Violet + Yellow
Violet + Orange
Violet + Slate
Violet + Black
Slate + Red
Slate + White
Slate + Green
40
41
42
43
44
45
46
47
48
49
50
51
State + Blue
Slate + Brown
Slate + Yellow
Slate + Orange
Slate + Black
White/Black + Red
White/Black + Green
White/Black + Blue
White/Black + Brown
White/Black + Yellow
White/Black + Orange
White/Black + Violet
Multipair Cables
Chart B
Pair
No.
Color
Combination
Pair
No.
Color
Combination
Pair
No.
Color
Combination
Pair
No.
Color
Combination
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
White +Black
White +Brown
White +Red
White +Orange
White +Yellow
White +Green
White +Blue
White +Violet
White +Slate
Black +Brown
Black +Red
Black +Orange
Black +Yellow
Black +Green
Black +Blue
Black +Violet
Black +Slate
Brown +Red
Brown +Orange
Brown +Yellow
Brown +Green
Brown +Blue
Brown +Violet
Brown +Slate
Red +Orange
Red +Yellow
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
Red +Green
Red +Blue
Red +Violet
Red +Slate
Orange +Yellow
Orange +Green
Orange +Blue
Orange +Violet
Orange +Slate
Yellow +Green
Yellow +Blue
Yellow +Violet
Yellow +Slate
Green +Blue
Green +Violet
Green +Slate
Blue +Violet
Blue +Slate
Violet +Slate
White/Black +Black
White/Black +Brown
White/Black +Red
White/Black +Orange
White/Black +Yellow
White/Black +Green
White/Black +Blue
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
White/Black +Violet
White/Black +Slate
White/Brown +Black
White/Brown +Brown
White/Brown +Red
White/Brown +Orange
White/Brown +Yellow
White/Brown +Green
White/Brown +Blue
White/Brown +Violet
White/Brown +Slate
White/Red +Black
White/Red +Brown
White/Red +Red
White/Red +Orange
White/Red +Yellow
White/Red +Green
White/Red +Blue
White/Red +Violet
White/Red +Slate
White/Orange +Black
White/Orange +Brown
White/Orange +Red
White/Orange +Orange
White/Orange +Yellow
White/Orange +Green
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
White/Orange +Blue
White/Orange +Violet
White/Orange +Slate
White/Yellow +Black
White/Yellow +Brown
White/Yellow +Red
White/Yellow +Orange
White/Yellow +Yellow
White/Yellow +Green
White/Yellow +Blue
White/Yellow +Violet
White/Yellow +Slate
White/Green +Black
White/Green +Brown
White/Green +Red
White/Green +Orange
White/Green +Yellow
White/Green +Green
White/Green +Blue
White/Green +Violet
White/Green +Slate
White/Blue +Black
White/Blue +Brown
White/Blue +Red
23
Conductor Color Coding
Multiconductor Cables
Chart D
No.
Base
Color
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Black
Red
White
Green
Orange
Blue
Brown
Yellow
Violet
Slate
Pink
Tan
Red
Red
Red
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
24
1st
Stripe
Green
Yellow
Black
Black
Red
Green
Yellow
Blue
Brown
Orange
Slate
Violet
Black
Black
Black
Black
Black
Black
Black
Black
Black
Red
2nd
Stripe
Red
Green
Yellow
Blue
Brown
Orange
Slate
Violet
Black
Black
3rd
Stripe
No.
Base
Color
1st
Stripe
2nd
Stripe
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Red
Red
Red
Red
Red
Green
Green
Green
Green
Green
Green
Blue
Blue
Blue
Blue
Blue
Blue
Brown
Brown
Brown
Brown
Brown
Brown
Violet
Violet
Violet
Black
Black
Black
Black
Black
Black
Black
Black
Red
Green
Blue
Brown
Violet
Black
Red
Green
Blue
Brown
Violet
Black
Red
Green
Blue
Brown
Violet
Black
Red
Green
Blue
Brown
Violet
Red
Green
Blue
Red
Red
Red
Red
Red
Red
Red
Green
3rd
Stripe
Green
Yellow
Blue
Brown
Orange
Slate
Violet
Yellow
No.
Base
Color
1st
Stripe
2nd
Stripe
3rd
Stripe
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Red
Green
Green
Green
Green
Green
Yellow
Yellow
Yellow
Yellow
Yellow
Blue
Blue
Blue
Blue
Brown
Brown
Brown
Orange
Orange
Slate
Black
Black
Black
Black
Black
Black
Black
Green
Green
Green
Green
Green
Blue
Brown
Orange
Slate
Violet
Blue
Brown
Orange
Slate
Violet
Brown
Orange
Slate
Violet
Orange
Slate
Violet
Slate
Violet
Violet
Green
Yellow
Blue
Brown
Orange
Slate
Violet
Yellow
Blue
Brown
Orange
Slate
Conductor Color Coding
Multiconductor Cables
Chart E
No. 1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
Base 1st 2nd
3rd
Color StripeStripeStripe
Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Slate
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Slate
Black
Black
Black
Black
Black
Black
Black
Black
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Red
Orange
Yellow
Green
Blue
Violet
Slate
Red
Orange
Yellow
Green
Blue
Violet
Slate
No. 35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Base 1st 2nd
3rd
Color StripeStripeStripe
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Red
Orange
Red
Yellow
Red
Green
Red
Blue
Red
Violet
Red
Slate
Orange Yellow
Orange Green
Orange Blue
Orange Violet
Orange Slate
Yellow Green
Yellow Blue
Yellow Violet
Yellow Slate
Green Blue
Green Violet
Green Slate
Blue
Violet
Blue
Slate
Violet Slate
Black Brown
Black Brown
Black Brown
Black Brown
Black Brown
Black Brown
Black Brown
Black Red
Black Red
Black Red
Black Red
Black Red
Black Orange
Red
Orange
Yellow
Green
Blue
Violet
Slate
Yellow
Green
Blue
Violet
Slate
Yellow
No. 69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
Base 1st 2nd
3rd
Color StripeStripeStripe
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
White
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Black
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Brown
Orange Green
Orange Blue
Orange Violet
Orange Slate
Yellow Green
Yellow Blue
Yellow Violet
Yellow Slate
Green Blue
Green Violet
Green Slate
Blue
Violet
Blue
Slate
Violet Slate
Red
Orange
Red
Yellow
Red
Green
Red
Blue
Red
Violet
Red
Slate
Orange Yellow
Orange Green
Orange Blue
Orange Violet
Orange Slate
Yellow Green
Yellow Blue
Yellow Violet
Yellow Slate
Green Blue
Green Violet
Green
Slate
25
Heat-Shrink Tubing
FIT®-221L LSZH
Heat-Shrink Tubing
UL 224
UL VW-1
Operating Temperature
• –55°C to +125°C (UL)
FIT-221L LSZH heat-shrink tubing
is a highly flexible, environmentally
friendly, flame-retardant option
to standard tubing. It contains no
lead, no halogens, has low-smoke
generation, and produces no toxic
fumes when burned, making it ideal
in helping OEMs and maintenance
personnel satisfy CA Prop 65 and
RoHS requirements in a variety of
applications. The tubing also meets
NASA’s definition of low outgassing.
Part No.
FIT-221L-3/64
FIT-221L-1/16
FIT-221L-3/32
FIT-221L-1/8
FIT-221L-3/16
FIT-221L-1/4
FIT-221L-3/8
FIT-221L-1/2
FIT-221L-3/4
FIT-221L-1IN
Supplied ID, Min.
Inch
mm
0.046
1.17
0.063
1.60
0.093
2.36
0.125
3.18
0.187
4.75
0.250
6.35
0.375
9.53
0.500
12.70
0.750
19.05
1.000
25.40
Shrink Temperature
• 100°C min.
• 110°C full recovery
Color
• Black
Material
• Cross-linked polyolefin
Electrical Properties
• 600 V (UL)
• Volume resistivity: 1014 ohm-cm
Physical Properties
• Tensile strength: 1500 psi
(10.34 N/mm2)
• Elongation: 200% min
• Longitudinal change: -10% to 0%
• Flame retarded
Recovered ID, Max.
Inch
mm
0.023
0.58
0.031
0.79
0.046
1.17
0.062
1.57
0.093
2.36
0.125
3.18
0.187
4.75
0.250
6.35
0.375
9.53
0.500
12.70
Recovered Wall Thickness, Nom.
Inch
mm
0.016
0.41
0.017
0.43
0.020
0.51
0.020
0.51
0.020
0.51
0.025
0.64
0.025
0.64
0.025
0.64
0.030
0.76
0.035
0.89
FIT-FILL Adhesive
Part No.
• FITFILL1
A unique adhesive filler, FIT-FILL is
amber bead-like balls of adhesive
that are ideal for use when additional
adhesive is needed, or when the
tubing does not effectively cover
the desired locations. FIT-FILL is an
ideal complement to FIT heat-shrink
tubing for applications involving
multiple wires in a tubing array, where
the tubing’s inner adhesive does not
touch the inner wires. FIT-FILL aids
in creating a better tubing-to-cable
seal to prevent water entry, while
providing extra protection to maintain
the integrity of the cable.
Material
• Modified Polyamide
26
Chemical Properties
• Corrosive effect: none
• Water absorption: 0.7% max.
• Low outgassing: Meets NASA’s
definition of low outgassing
with TML of 1.0% and CVCM of
less than 0.01%
• Lead free
• Halogen free
• Antimony free
Availability
Feet
m
1000
305
1000
305
500
152
200
60.9
500
152
200
60.9
200
60.9
200
60.9
200
60.9
200
60.9
Color
• Amber
Dimensions
• ID: 0.138” (3.51 mm)
• OD: 0.295” (7.49 mm)
• Opening: 0.055” (1.40 mm)
• Length: 0.197” (5 mm)
Shrink Temperature
• 90°C
Operating Temperature
• -10°C to 105°C
Availability
• Packs of 1000
Heat-Shrink Tubing
Heat-Shrink Tubing
for Every Need
Material
Thin-wall irradiated
polyolefin
Cross-linked polyolefin
Flame-retardant
cross-linked polyolefin
Cross-linked polyolefin
Semirigid cross-linked
polyolefin
Surface cross-linked,
dual extruded
Bonding, thermoplastic
adhesive lined
Bonding, adhesive
lined
Irradiated PVC
Cross-linked PVDF
FEP
PTFE
Chlorinated
polyolefin
Flexible
fluoroelastomer
Polyethylene/
polyester
Cross-linked silicone
rubber
Cross-linked PVDF
Features
Shrink Temperature
Single-Wall Cross-linked Polyolefin for General-Purpose Use
LSZH: reduced
smoke generation and gas emission
-55°C to 105°C
Low outgassing
90°C
General-purpose heat-shrink tubing
Range of shrink ratios
90°C
90°C
Low shrink temp
Passes UL VW-1 flame test
90°C
Approved for 600-V ground lead identification
Green with yellow stripe
90°C
Passes UL VW-1 flame test
30% stronger and 25% stiffer than
110°C
standard polyolefin
Dual-Wall Polyolefin for Additional Sealing
140°C
Meltable inner wall to encapsulate
110°C
without adhesive
121°C
Bonds to most materials
120°C
High voltage: to 2 kV at 90°C continuous use
Permanent water and corrosion protection
110°C
Special-Application Tubing
Low shrink temperature
Passes UL VW-1 flame test
100°C
30% stronger than standard polyolefin
High shrink temperature
Fast recovery time
Excellent chemical, heat, and flame resistance
170°C
Passes UL VW-1 flame test
3x the tensile strength of standard polyolefin
High shrink temperature
Excellent chemical resistance
200°C
Excellent dielectric properties
Thinnest wall thickness available
High shrink temperature
Excellent chemical resistance
250°C
Excellent dielectric properties
Very thin wall thickness
Highly flexible
Oil and abrasion resistant
130°C
Passes UL VW-1 flame test
High shrink temperature
Excellent chemical resistance
120°C
Flexible
Superior abrasion resistance
Excellent flexibility
80°C
Resists harsh environments
High flexibility available
Pliable
200°C
Scrape abrasion resistant
Passes UL VW-1 flame test
Transparent after shrink
Fast recovery time
Excellent chemical, heat, and flame resistance
150°C
Passes UL VW-1 flame test
2x the tensile strength of standard polyolefin
Shrink Ratio (approx.)
FIT Family
2:1
FIT-221L
2:1
4:1
2:1
3:1
FIT-221
FIT-421
FIT-221V
FIT-321V
2:1
FIT-260
2:1
FIT-295
2.5:1
3:1
5.6:1
FIT-300
FIT-321
FIT-621
3:1
FIT-700
2:1
FIT-750
2:1
FIT-105
2:1
FIT-350
1.2:1
FIT-400
1.5:1
FIT-500
2:1
FIT-600
2:1
FIT-650
2:1
FIT-FABRIC
1.7:1
FIT-FLEX
2:1
FIT-CLEAR
27
The cables you trust.
The service you deserve.
Every application is critical and
cable failure is not an option
when the safety of equipment
and personnel is paramount.
Specify Alpha cable for rugged,
reliable performance, since the
integrity of your system is only as
robust as the products you use.
GLOBAL HEADQUARTERS
711 Lidgerwood Avenue
Elizabeth, NJ 07207-0711 USA
Toll Free: 1-800-52 ALPHA
Tel: 1-908-925-8000
Fax: 1-908-925-5411
E-mail: [email protected]
Custom cable is standard
Alpha Wire goes one step
further: manufacturing
custom cables to meet unique
applications—offering specific
conductor counts, shielding
options, jacket materials, and
versatile product designs. Our
custom cable orders are often
shipped in less than a week,
once again giving you products
with more convenience and
less delay.
EUROPE
Alpha Wire International
Saxon House
1 Downside | Sunbury-on-Thames
Middlesex | United Kingdom | TW16 6RT
Tel: 01 932 772 422
Fax: 01 932 772 433
E-mail: [email protected]
Service and support,
second-to-none
Selecting the correct cable
for your critical application is
essential to overall system
reliability, performance, and
safety. So we make it easy
for you to select the right
Alpha cable for your specific
application. Our online
resources include a wire and
cable selection guide, technical
information, full product
catalog, and a distributor
locator to make it easy to
select and get the cable you
need. Can’t find what you’re
looking for? Design the cable
to your specification. It’s easy,
just visit www.alphawire.com!
ASIA PACIFIC
Alpha Wire
Silver Center | Room 1712
North Shanxi Road 1388
Shanghai | China | 200060
Tel: +86-21-61498201/61498205
Fax: +86-21-61498001
E-mail: [email protected]
©2015 Alpha Wire. All rights reserved. Specifications subject to change.
Consult Alpha Wire for latest specifications. EcoCable, EcoFlex, EcoGen, EcoWire, and EcoWire Plus are trademarks of Alpha Wire.
Lit. No. ProTekt-Cat-1504
Supersedes: ProTekt-Cat-1410