Datasheet

UNISONIC TECHNOLOGIES CO., LTD
BTA324A
Preliminary
TRIAC
25A TRIACS

DESCRIPTION
The UTC BTA324A is a 25A triacs which can be operated in 3
quadrants only, it uses UTC’s advanced technology to provide
customers with high commutation performances, etc.
The UTC BTA324A is suitable for inductive load switching
operations, also can be used in ON/OFF function applications such
as induction motor starting circuits, heating regulation, static relays
etc.

SYMBOL

ORDERING INFORMATION
Ordering Number
Package
Lead Free
Halogen Free
BTA324AL-x-xx-TF3-T
BTA324AG-x-xx-TF3-T
TO-220F
Note: Pin Assignment: MT1: MT1 MT2: MT2 G: Gate

Packing
Tube
SENSITIVITY AND TYPE
PART NUMBER
BW
CW
◎: Available

Pin Assignment
1
2
3
MT1 MT2
G
VOLTAGE
600V
◎
◎
800V
◎
◎
SENSITIVITY
TYPE
50mA
35mA
SNUBBERLESS
SNUBBERLESS
MARKING
www.unisonic.com.tw
Copyright © 2016 Unisonic Technologies Co., Ltd
1 of 3
QW-R401-028.e
BTA324A

Preliminary
TRIAC
ABSOLUTE MAXIMUM RATINGS
PARAMETER
RMS On-State Current (Full Sine Wave) TC=75°C
Non Repetitive Surge Peak F=50 Hz t=20ms
On-State Current (Full
F=60 Hz t=16.7ms
Cycle, TJ initial=25°C)
SYMBOL
IT(RMS)
ITSM
RATINGS
25
UNIT
A
250
A
260
A
I2t Value for Fusing
tP=10ms
I2 t
340
A2s
Critical Rate of Rise of
On-State Current IG=2xIGT, F=120 Hz TJ=125°C
dI/dt
50
A/µs
tr≤100ns
Non Repetitive Surge Peak
tP=10ms TJ=25°C
VDSM/VRSM
VDRM/VRRM+100
V
Off-State Voltage
Peak Gate Current
tP=20µs
TJ=125°C
IGM
4
A
Average Gate Power Dissipation
TJ=125°C
PG(AV)
1
W
Operating Junction Temperature
TJ
-40~+125
°C
Storage Junction Temperature
TSTG
-40~+150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

THERMAL RESISTANCES
PARAMETER
Junction to Ambient
Junction to Case (AC)

SYMBOL
θJA
θJC
RATINGS
60
1.7
UNIT
°C/W
°C/W
ELECTRICAL CHARACTERISTICS (TJ =25°C unless otherwise specified.)
FOR SNUBBERLESS (3 QUADRANTS)
PARAMETER
SYMBOL
SNUBBERLESS TYPE (3 QUADRANTS)
Gate Trigger Current (Note 1)
IGT
Gate Trigger Voltage
VGT
Gate Non-Trigger Voltage
VGD
Holding Current (Note 2)
IH
Latching Current
Critical Rate of Rise of Off-State
Voltage (Note 2)
Critical Rate of Rise of Off-State
Voltage at Commutation
(Note 2)

IL
dV/dt
(dI/dt)c
TEST CONDITIONS
VD=12V,
RL=33Ω
VD=VDRM,
RL=3.3kΩ,
TJ=125°C
IT=500mA
CW
BW
UNIT
MIN TYP MAX MIN TYP MAX
I-II-III
I-II-III
I-II-III
I-III
IG=1.2IGT
II
VD=67%VDRM, Gate
Open, TJ=125°C
Without Snubber,
TJ=125°C
35
1.3
0.2
50
1.3
0.2
50
70
80
mA
V
V
75
80
100
mA
mA
mA
500
1000
V/µs
13
22
A/ms
STATIC CHARACTERISTICS
PARAMETER
Peak On-State Voltage (Note 2)
Threshold Voltage (Note 2)
Dynamic Resistance (Note 2)
SYMBOL
TEST CONDITIONS
VTM
ITM=35A, tP=380μs TJ=25°C
VTO
TJ=125°C
RD
TJ=125°C
IDRM
TJ=25°C
Repetitive Peak Off-State Current
VDRM=VRRM
IRRM
TJ=125°C
Note: 1. Minimum IGT is guaranteed at 5% of IGT max.
2. For both polarities of MT2 referenced to MT1.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
TYP MAX UNIT
1.55
V
0.85
V
16
mΩ
5
μA
3
mA
2 of 3
QW-R401-028.e
BTA324A
Preliminary
TRIAC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 3
QW-R401-028.e