Datasheet

UNISONIC TECHNOLOGIES CO., LTD
SM2LZ47
Preliminary
TRIAC
2A TRIACS
DESCRIPTION

The UTC SM2LZ47 is a 2A Triac, it uses UTC’s advanced
technology to provide customers with high critical rate of rise of
off-state voltage at communication, high repetitive peak off-state
voltage and high R.M.S. on-state current, etc.
The UTC SM2LZ47 is suitable for AC power control applications,
etc.
FEATURES

* High R.M.S. On−State Current: 2A
* High Repetitive Peak Off−State Voltage: 800V
* High Critical Rate of Rise of Off-State Voltage at
Communication(Min.=5V/μs)
SYMBOL

MT2
G
MT1

ORDERING INFORMATION
Order Number
Package
Lead Free
Halogen Free
SM2LZ47L-TA3T
SM2LZ47G-TA3-T
TO-220
SM2LZ47L-TF1-T
SM2LZ47G-TF1-T
TO-220F1
SM2LZ47L-TF3-T
SM2LZ47G-TF3-T
TO-220F
Note: Pin Assignment: MT1: MT1 MT2: MT2 G: GATE

Pin Assignment
1
2
3
MT1 MT2
G
MT1 MT2
G
MT1 MT2
G
Packing
Tube
Tube
Tube
MARKING
www.unisonic.com.tw
Copyright © 2016 Unisonic Technologies Co., Ltd
1 of 3
QW-R401-049.b
SM2LZ47

Preliminary
TRIAC
ABSOLUTE MAXIMUM RATINGS
PARAMETER
SYMBOL
RATINGS
UNIT
Repetitive Peak Off-State Voltages
VDRM
800
V
R. M. S On-State Current (Full Sine Waveform)
IT(RMS)
2
A
Non Repetitive Peak One Cycle Surge 50Hz
8
A
ITSM
On-State Current
8.8
A
60Hz
I2t Limit Value
I2t
0.32
A2s
Critical Rate of Rise of On-State Current (Note 1)
dI/dt
50
A/µs
Peak Gate Power Dissipation
PGM
3
W
Average Gate Power Dissipation
PG(AV)
0.3
W
Peak Gate Voltage
VFGM
10
V
Peak Gate Current
IGM
1.6
A
Isolation Voltage (AC, t=1min.)
VISOL
1500
V
Junction Temperature
TJ
-40~125
°C
Storage Temperature
TSTG
-40~125
°C
Notes: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.
2. dI/dt test condition;VDRM= 400V, ITM ≤ 3A, tgw≥ 0μs, tgr≤250ns, igp=IGT×2.0

THERMAL RESISTANCES
PARAMETER
Junction to Ambient (AC)

SYMBOL
θJA
RATINGS
58
UNIT
°C/W
ELECTRICAL CHARACTERISTICS (TA=25˚C)
PARAMETER
Repetitive Peak Off-State Current
SYMBOL
IDRM
Gate Trigger Voltage
VGT
Gate Trigger Current
IGT
Peak On-State Voltage
Gate Non-Trigger Voltage
Holding Current
Critical Rate of Rise of Off-State
Voltage
Critical Rate of Rise of Off-State
Voltage at Communication
VTM
VGD
IH
dV/dt
(dV/dt)c
TEST CONDITIONS
VDRM=800V
T2+ G+
VD=12V, RL=20Ω
T2+ GT2- GT2+ G+
VD=12V, RL=20Ω
T2+ GT2- GITM=3A
VD=800V, TC=125°C
VD=12V, ITM=1A
VDRM=800V, TJ=125°C, Exponential
Rise
VDRM=400V, TJ=125°C,
(dI/dt)c=-0.5A/ms
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN TYP MAX UNIT
20
µA
1.5
V
1.5
1.5
10
mA
10
10
2.0
V
0.2
V
10
mA
500
5
V/µs
V/µs
2 of 3
QW-R401-049.b
SM2LZ47
Preliminary
TRIAC
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 3
QW-R401-049.b