UNISONIC TECHNOLOGIES CO., LTD SM2LZ47 Preliminary TRIAC 2A TRIACS DESCRIPTION The UTC SM2LZ47 is a 2A Triac, it uses UTC’s advanced technology to provide customers with high critical rate of rise of off-state voltage at communication, high repetitive peak off-state voltage and high R.M.S. on-state current, etc. The UTC SM2LZ47 is suitable for AC power control applications, etc. FEATURES * High R.M.S. On−State Current: 2A * High Repetitive Peak Off−State Voltage: 800V * High Critical Rate of Rise of Off-State Voltage at Communication(Min.=5V/μs) SYMBOL MT2 G MT1 ORDERING INFORMATION Order Number Package Lead Free Halogen Free SM2LZ47L-TA3T SM2LZ47G-TA3-T TO-220 SM2LZ47L-TF1-T SM2LZ47G-TF1-T TO-220F1 SM2LZ47L-TF3-T SM2LZ47G-TF3-T TO-220F Note: Pin Assignment: MT1: MT1 MT2: MT2 G: GATE Pin Assignment 1 2 3 MT1 MT2 G MT1 MT2 G MT1 MT2 G Packing Tube Tube Tube MARKING www.unisonic.com.tw Copyright © 2016 Unisonic Technologies Co., Ltd 1 of 3 QW-R401-049.b SM2LZ47 Preliminary TRIAC ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL RATINGS UNIT Repetitive Peak Off-State Voltages VDRM 800 V R. M. S On-State Current (Full Sine Waveform) IT(RMS) 2 A Non Repetitive Peak One Cycle Surge 50Hz 8 A ITSM On-State Current 8.8 A 60Hz I2t Limit Value I2t 0.32 A2s Critical Rate of Rise of On-State Current (Note 1) dI/dt 50 A/µs Peak Gate Power Dissipation PGM 3 W Average Gate Power Dissipation PG(AV) 0.3 W Peak Gate Voltage VFGM 10 V Peak Gate Current IGM 1.6 A Isolation Voltage (AC, t=1min.) VISOL 1500 V Junction Temperature TJ -40~125 °C Storage Temperature TSTG -40~125 °C Notes: 1. Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. 2. dI/dt test condition;VDRM= 400V, ITM ≤ 3A, tgw≥ 0μs, tgr≤250ns, igp=IGT×2.0 THERMAL RESISTANCES PARAMETER Junction to Ambient (AC) SYMBOL θJA RATINGS 58 UNIT °C/W ELECTRICAL CHARACTERISTICS (TA=25˚C) PARAMETER Repetitive Peak Off-State Current SYMBOL IDRM Gate Trigger Voltage VGT Gate Trigger Current IGT Peak On-State Voltage Gate Non-Trigger Voltage Holding Current Critical Rate of Rise of Off-State Voltage Critical Rate of Rise of Off-State Voltage at Communication VTM VGD IH dV/dt (dV/dt)c TEST CONDITIONS VDRM=800V T2+ G+ VD=12V, RL=20Ω T2+ GT2- GT2+ G+ VD=12V, RL=20Ω T2+ GT2- GITM=3A VD=800V, TC=125°C VD=12V, ITM=1A VDRM=800V, TJ=125°C, Exponential Rise VDRM=400V, TJ=125°C, (dI/dt)c=-0.5A/ms UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw MIN TYP MAX UNIT 20 µA 1.5 V 1.5 1.5 10 mA 10 10 2.0 V 0.2 V 10 mA 500 5 V/µs V/µs 2 of 3 QW-R401-049.b SM2LZ47 Preliminary TRIAC UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 3 of 3 QW-R401-049.b