GSC25 Safety Certificates

File E135803
Project 99SC56151
2000-01-18
REPORT
ON
COMPONENT - POWER SUPPLIES,
INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING
ELECTRICAL BUSINESS EQUIPMENT
Condor DC Power Supplies Inc.
Oxnard, California
Copyright © 2000 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above-named company to reproduce
this Report provided it is reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above-named company to reproduce
that portion of this Report consisting of this Cover Page through Page 2.
File E135803
Vol. 2
Sec. 7
and Report
Page 1
Issued:
Revised:
2000-01-18
2003-12-11
DESCRIPTION
PRODUCT COVERED:
G.
USR, Switching Power Supply, Model GSC25 followed by suffixes A, B, D or
May or may not be followed by -LC.
ELECTRICAL RATINGS:
Input:
Outputs:
MODEL
GSC25A
GSC25B
GSC25D
GSC25G
100-240 V ac, 50/60 Hz, 0.9 A.
Maximum output power is 25 W with convection cooling.
Output
V
5.1
5.1
5.1
3.3
#1
A
2.5
2.5
2.5
2.5
V
+12
+15
+24
+12
#2
A
1.5
1.5
1.0
1.5
V
-12
-15
-12
-12
#3
A
0.2
0.2
0.2
0.2
ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE):
This product is for use only in (or with) complete equipment where the
acceptability of the combination is determined by Underwriters Laboratories
Inc.
USR/CNR indicates investigation to the U.S. and Canadian (Bi-National)
Standard for Safety of Information Technology Equipment, CAN/CSA C22.2 No.
60950-00 * UL 60950, Third Edition.
The equipment is for building in, Class I (earthed), for use on a TN
power system.
Conditions of Acceptability - When installed in the end-use equipment,
the following are among the considerations to be made:
1.
This component has been judged on the basis of the required spacings in
the Standard for Information Technology Equipment, Including Electrical
Business Equipment, CAN/CSA C22.2 No. 60950-00 * UL 60950, Third Edition,
which would cover the component itself if submitted for unrestricted listing.
File E135803
Vol. 2
Sec. 7
and Report
Page 2
Issued:
Revised:
2000-01-18
2003-12-11
2.
All secondary output circuits are SELV and are not hazardous energy
levels.
3.
The terminals and connectors have not been evaluated for field wiring.
4.
The power supply shall be properly bonded to the main protective
earthing termination in the end product as this unit was investigated
for Class I construction as defined in UL 60950. An additional
evaluation shall be made if the power supply is intended for use in
other than Class I equipment.
5.
Bonding terminals provided on this equipment have not been evaluated as
protective earthing terminals.
6.
Magnetic device transformer T2 employs an OBJY2 electrical insulation
system designated Class F (155°°C). Inductor T1 employs bobbin material
rated 150°C in the thickness used.
7.
The equipment has been evaluated for use in a Pollution Degree 2
environment.
8.
The component shall be installed in compliance with the enclosure,
mounting, spacing, casualty markings and segregation requirements of the
end-use application.
9.
This power supply was evaluated for use in a 50°C ambient. An
additional evaluation should be made if the power supply is intended to
be used in an elevated ambient.
*
DC Power Supplies, Inc.
STATEMENT OF COMPLIANCE
File Number: LR 46516
Date Issued: December 16, 2003
In accordance with the conditions established by the CSA Category
Certification Program, the models listed below are eligible to bear the CSA
mark.
Issued By: Ross Sacolles
Product Safety Engineer
Signature:
CLASS
5311-07 - POWER SUPPLIES - Component Type
PRODUCTS
Component power supplies for use in Information Technology Equipment, where the suitability
of the combination is to be determined by the Canadian Standards Association.
Component Type Switching Power Supply, GSC25 Series with suffix A, B, D or G with optional
–LC (chassis/cover), input rated 100-240 V ac, 0.9 A, 50/60 Hz; dc outputs rated
Classification Level (L3M1), 25 W max, as follows:
Suffix:
A: +5.1 V dc/2.5 A, +12 V dc/1.5 A, -12 V dc/0.2 A
B: +5.1 V dc/2.5 A, +15 V dc/1.5 A, -15 V dc/0.2 A
D: +5.1 V dc/2.5 A, +24 V dc/1 A, -12 V dc/0.2 A
G: +3.3 V dc/2.5 A, +12 V dc/1.5 A, -12 V dc/0.2 A
Notes:
1. Maximum ambient temperature for rated output current is 50 °C.
2. Maximum operating relative humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of
power.
APPLICABLE REQUIREMENTS
CAN/CSA-C22.2 No. 60950-1-03 -
Information Technology Equipment – Safety – Part1:
General Requirements