File E135803 Project 99SC56151 2000-01-18 REPORT ON COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Condor DC Power Supplies Inc. Oxnard, California Copyright © 2000 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above-named company to reproduce that portion of this Report consisting of this Cover Page through Page 2. File E135803 Vol. 2 Sec. 7 and Report Page 1 Issued: Revised: 2000-01-18 2003-12-11 DESCRIPTION PRODUCT COVERED: G. USR, Switching Power Supply, Model GSC25 followed by suffixes A, B, D or May or may not be followed by -LC. ELECTRICAL RATINGS: Input: Outputs: MODEL GSC25A GSC25B GSC25D GSC25G 100-240 V ac, 50/60 Hz, 0.9 A. Maximum output power is 25 W with convection cooling. Output V 5.1 5.1 5.1 3.3 #1 A 2.5 2.5 2.5 2.5 V +12 +15 +24 +12 #2 A 1.5 1.5 1.0 1.5 V -12 -15 -12 -12 #3 A 0.2 0.2 0.2 0.2 ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE): This product is for use only in (or with) complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. USR/CNR indicates investigation to the U.S. and Canadian (Bi-National) Standard for Safety of Information Technology Equipment, CAN/CSA C22.2 No. 60950-00 * UL 60950, Third Edition. The equipment is for building in, Class I (earthed), for use on a TN power system. Conditions of Acceptability - When installed in the end-use equipment, the following are among the considerations to be made: 1. This component has been judged on the basis of the required spacings in the Standard for Information Technology Equipment, Including Electrical Business Equipment, CAN/CSA C22.2 No. 60950-00 * UL 60950, Third Edition, which would cover the component itself if submitted for unrestricted listing. File E135803 Vol. 2 Sec. 7 and Report Page 2 Issued: Revised: 2000-01-18 2003-12-11 2. All secondary output circuits are SELV and are not hazardous energy levels. 3. The terminals and connectors have not been evaluated for field wiring. 4. The power supply shall be properly bonded to the main protective earthing termination in the end product as this unit was investigated for Class I construction as defined in UL 60950. An additional evaluation shall be made if the power supply is intended for use in other than Class I equipment. 5. Bonding terminals provided on this equipment have not been evaluated as protective earthing terminals. 6. Magnetic device transformer T2 employs an OBJY2 electrical insulation system designated Class F (155°°C). Inductor T1 employs bobbin material rated 150°C in the thickness used. 7. The equipment has been evaluated for use in a Pollution Degree 2 environment. 8. The component shall be installed in compliance with the enclosure, mounting, spacing, casualty markings and segregation requirements of the end-use application. 9. This power supply was evaluated for use in a 50°C ambient. An additional evaluation should be made if the power supply is intended to be used in an elevated ambient. * DC Power Supplies, Inc. STATEMENT OF COMPLIANCE File Number: LR 46516 Date Issued: December 16, 2003 In accordance with the conditions established by the CSA Category Certification Program, the models listed below are eligible to bear the CSA mark. Issued By: Ross Sacolles Product Safety Engineer Signature: CLASS 5311-07 - POWER SUPPLIES - Component Type PRODUCTS Component power supplies for use in Information Technology Equipment, where the suitability of the combination is to be determined by the Canadian Standards Association. Component Type Switching Power Supply, GSC25 Series with suffix A, B, D or G with optional –LC (chassis/cover), input rated 100-240 V ac, 0.9 A, 50/60 Hz; dc outputs rated Classification Level (L3M1), 25 W max, as follows: Suffix: A: +5.1 V dc/2.5 A, +12 V dc/1.5 A, -12 V dc/0.2 A B: +5.1 V dc/2.5 A, +15 V dc/1.5 A, -15 V dc/0.2 A D: +5.1 V dc/2.5 A, +24 V dc/1 A, -12 V dc/0.2 A G: +3.3 V dc/2.5 A, +12 V dc/1.5 A, -12 V dc/0.2 A Notes: 1. Maximum ambient temperature for rated output current is 50 °C. 2. Maximum operating relative humidity 96 %, no condensation. 3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power. APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No. 60950-1-03 - Information Technology Equipment – Safety – Part1: General Requirements