GSC25 Instructions

CONDOR DC POWER SUPPLIES INC.
2311 STATHAM PKWY
OXNARD, CA 93033 + 805-486-4565
GSC25 SERIES
INSTALLATION INSTRUCTIONS
RATINGS:
Input: 100-240 V ac, 0.9 A, 50/60 Hz
Outputs:
Model
Watts1
Output #1
GSC25A
25
+5.1 V dc 2.5 A
GSC25B
25
+5.1 V dc 2.5 A
GSC25D
25
+5.1 V dc 2.5 A
GSC25G
25
+3.3 V dc 2.5 A
Output #2
+12 V dc 1.5 A
+15 V dc 1.5 A
+24 V dc 1 A
+12 V dc 1.5 A
Output #3
-12 V dc 0.2 A
-15 V dc 0.2 A
-12 V dc 0.2 A
-12 V dc 0.2 A
Notes:
1. Maximum continuous output power at 50 °C - Total of all Outputs with or without chassis/cover (-LC suffix) option.
2. Maximum Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: Condor DC Power Supplies, Inc. declares under our sole responsibility that
all models listed above are in conformity with the applicable requirements of EN 60950-1 following the
provisions of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the
applicable requirements of UL 60950, CAN/CSA 22.2 No. 60950-1, EN 60950-1, and IEC 60950-1 for Pollution Degree 2
environment and Class I TN-S power systems. The outputs of the supplies meet the requirements for SELV and are not an
energy hazard.
GROUNDING: The ground terminal must be bonded to Earth in the end application. Using this terminal for the primary
system earthing terminal is not recommended.
SPACINGS: Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the
applicable safety standards, must be maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in the applicable safety
standards, must not be exceeded after installation to preserve the intended safety. The output power, ambient air temperature
and the availability, amount, direction and/or restriction of airflow influence the temperatures of these components.
WARNING! RISK OF FIRE! A blown fuse is an indication of catastrophic failure of circuit component(s). Repair must
be performed by Condor authorized personnel. Fuse F1 must be replaced with T 2 A/250 V (slow blow), UL Listed and CSA
Certified type.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring traces and heatsinks.
CONNECTIONS
J1 Pin
1
3
AC Input
Line
Neutral
J2 Pin
1
2
3
4
5
6
DC Output
Output #2 (+)
Output #1 (+)
Output #1 (+)
Common
Common
Output #3 (-)
MATING CONNECTORS
J1 AMP Housing 640250-3 Contact 770522-1
J2 AMP Housing 640250-6 Contact 770522-1
EXPLANATION OF SYMBOLS
Alternating Current
Attention, Consult
Accom panying Docum ents
Attention, Dangerous Voltages
Earth (Ground)
Condor DC Power Supplies Inc. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other
than authorized agents of Condor DC Power Supplies Inc., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA,
and EN/IEC safety standards.
41-34484-0001 Rev. D 04/19/04