TB110S Datasheet

TB110S
110W Single Output
Test and Measurement/Industrial Series
Features

2” x 4” x 1.3” Package

Up to 110W Output Power

Compliant to high levels of EMC per EN61000-4


15kV ESD (Air), 8kV (Contact)
4kV Surge

Meets Class B Conducted EMI with 6db margin,
Class B Radiated EMI with 3db margin

Up to 90% Efficiency

>10 year e-cap life

Universal Input 90-264Vac Input Range

DC OK Signal, Inhibit, Power Good Signals

5V @ 1A Standby Output

Class I and II Input Models

3 Year Warranty
Description
A Superior performance 110 Watts AC to DC power supply designed for Test and Measurement and Industrial applications. Feature
rich and highly efficient TB110S product family can easily fit in 1U chassis and provides up to 110Watts. Long Life as determined by
e-cap life calculations and a 5V@1A standby output are key features. All models are CE marked to low voltage directive and
approved to ITE standards of IEC/UL/EN60950 and CSA C22.2, 2nd edition.
Model Selection
Model
Number4
TB110S12K
Output
Voltage (Nom)
12V
TB110S24K
24V
4.3A
3.3A
TB110S48K
48V
2.1A
1.6A
Notes:
1.
2.
3.
4.
Output Current
w/Air
Convection
8.7A
6.7A
Ripple & Noise2
(pk-pk)
120mV
Total
Regulation
OVP
Threshold
±2%
15.0 ± 2.0V
MTBF3
500,000
89%
240mV
±2%
28.0 ± 2.5V
500,000
89%
480mV
±2%
55.0 ± 4.0V
500,000
Efficiency
89%
1
Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C.
Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient
temperatures below 0°C.
MTBF values are in hours, per Telcordia 332, Issue 6, 25°C, full rated load (w/airflow) at 110Vac input.
Change the “K” suffix to “C” for Input Class II (ungrounded) models.
General Specifications
AC Input
85-264Vac, single phase.
(Safety Approved to 90-264Vac).
Turn On Time
Input Current
TBDA at 110Vac, TBDA at 240Vac
Rise Time
Inrush Current
40Arms Maximum within a half line cycle, cold
start at 25C. See application note.
Earth Leakage
Current
<500mA@264Vac, 60Hz input, NC
www.slpower.com
TB110 REV 1.1
Hold-up Time
Over Load
Protection (OCP)
12-MAY-16
Main Output: <1 Seconds at 115Vac
5Vsb Output: <250mSec at 115Vac
Main Output: <70mSec
5Vsb Output: <70mSec
Main Output: 20mSec min.
5Vsb Output: 100mSec min.
from loss of AC input at 115 Vac, full load, 25°C.
115% - 200% of rated output current value.
Hiccup Mode, Auto-recovery
PRELIMINARY
1
TB110S
110W Single Output
Test and Measurement/Industrial Series
General Specifications
Turn-On Input
Voltage
70-85Va, Full spec performance at 85Vac.
Short Circuit
Protection (SCP)
Short across the output terminals will not cause
damage to the unit. Hiccup Mode , Auto-recovery
Turn-Off Input
Voltage
<75Vac ± 8Vac
Over Voltage
Protection (OVP)
Latches off when output voltage is with range as
shown in table. Requires AC Power cycle to reset
Input Fuses
Output Voltage
Voltage Adjustability
3.15A, 250Vac, line and neutral inputs
Over Temperature
Protection (OTP)
12V to 48Vdc. See models chart for part
numbering.
Output Reverse
Voltage Protection
Isolation
+/- 10%
Power shuts down at temperature of TBD (typical) at
full load. Auto-recovery.
Outputs protected against momentary reverse
current less than 20A peak for less than 10mS with
0.5A average. Sustained reverse current at high
levels may damage unit.
Input-Output:
3000Vac
Input-Ground: 1800Vac
Output-Ground: 500Vac
88% - 90% typical at 115/230Vac, 25°C.
Turn-On &
Operating
Temperature
-20°C to +70°C.
Turn on Temperature = -40°C at >=120Vac
Output Power
110W with 200LFM airflow; 80W convection
cooled, -20C to 50°C ambient. 85Vac to 264Vac.
See chart for de-rating above 50°C.
Storage
Temperature
-40°C to +85°C
Transient Response
500µS typ. response time for return to within
0.5% of final value for a 50% load change, ∆i/∆t<
0.2A/µs. Max. volt. deviation is ±3.5%.
Altitude
Efficiency
Minimum Load
Total Regulation
Relative Humidity
Not required.
IPC 610
±2.0 % for all models.
Overshoot
<2% overshoot at turn-on, <1% overshoot at turnoff, under all conditions.
E-Cap Life
>10 Years in use condition of 40°C ambient, at
12h/day, 261 days/year. Additional information
on other use profiles available on request.
Shock
(IEC 60068-2-27)
Dimensions
Operating: Half-sine shock waveform. Impact
Acceleration: 20g, Pulse duration: 11mS.
Cycles: 3 times per axis in X,Y, Z direction
Non-Operating: Half-sine shock waveform.
Impact Acceleration: 100g, Pulse duration: 6mS
Cycles: 3 times per direction on 3 axes (X,Y. Z)
Safety Standards
MTBF
Vibration
(IEC 60068-2-6)
(IEC 60068-2-64)
Weight
W: 2.0” x L: 4.0” x H: 1.4”
Operating:
-500m to 5000m
Non-operating: -500 to 40,000 feet
5% to 95%, non-condensing
Class 2
IEC 60950-1, 2nd Edition
CAN/CSA – C22.2 No 60950-1
DEMKO EN60950-1
>500,000 hours @ 110/220Vac, 25°C, GB
Telcordia 332 issue 3.
Operating: Sinusoidal Frequency: 10-500Hz, Impact
Acceleration: 1g, Sweep rate: 1 octave/min
Cycles: 10 times per axis in X, Y, Z direction
Random Vibration:
Operating: 0.003g2/Hz, 1.224grms overall, 3 axes, 10
min per axis, 1-500Hz.
Non-Operating: 0.02g2/Hz, 3.1grms overall, 3 axes, 1
hour per axis, 20-500 Hz
180g, typical
Auxiliary Signals
DC OK:
Goes HIGH when main DC output is above 90%
of nominal voltage and goes LOW when the
output is below 90% of rated main output DC
voltage
Power Good/Power
Fail:
Signal is high after the main output is within regulation
band upon AC turn on. Goes low with 4mS min. before
the main DC output drops below 90% of nominal value
when AC turns off.
Inhibit:
Logic HIGH or open = ON
Logic LOW or short to ground = OFF
5V Standby Output:
5V @ 1A, +/-5% regulation over all
changes in main output load current.
www.slpower.com
TB110 REV 1.1
12-MAY-16
PRELIMINARY
2
TB110S
110W Single Output
Test and Measurement/Industrial Series
EMI/EMC Compliance
Conducted Emissions
EN55022/CISPR22 Class B, FCC Part 15.107, Class B, 6db margin, typical.
Radiated Emissions
EN55022/CISPR22 Class B, FCC Part 15.109, Class B, 3db margin, typical.
Common Mode Noise: High Frequency
(100Khz -20 Mhz)
Common Mode Noise: Low Frequency
(50-120 Hz)
<50mA pk-pk, 6mA rms CM current. See Application Note.
<50mA pk-pk, 6mA rms CM current. See Application Note.
Static Discharge Immunity
EN55024/IEC61000-4-2, Level 4, 8kV Contact Discharge, 15kV air discharge, Criteria A
Radiated RF Immunity
EN55022/IEC61000-4-3, Level 3, 10V/m, Criteria A
EFT/Burst Immunity
EN55024/IEC61000-4-4, Level 3, 4kV (PS Output), Criteria A; 2kV (signal outputs), Criteria B
Line Surge Immunity
EN55024/IEC61000-4-5, Level 4, 2kV diff., 4kV Common-mode, Criteria A
Conducted RF Immunity
EN55022/IEC61000-4-6, Level 3, 10V/m, Criteria A
Power Frequency Magnetic Field Immunity
EN55024/IEC61000-4-8, Level 4, 30A/m, Criteria A
Voltage Dip Immunity
EN55024/IEC61000-4-11, Dips: 100%, 10ms; 30%, 500ms; 60%, 100ms;
Interruptions: 100%, 5000mS; Performance Criteria A, A, B & B
Line Harmonic Emissions
EN55024/IEC61000-3-2, Class A.
Flicker Test
EN55024/IEC61000-3-3
Notes:
Performance criteria are based on EN55024. According to the standards, performance criteria are defined as following:
A – Normal performance during and after the test
B – Temporary degradation, self-recoverable
C – Temporary degradation, operator intervention required to recover the operation
D – Permanent damage
Isolation Specifications
Parameter
Conditions/Description
Insulation Safety Rating
Input/Ground
Input/Output
Output/Ground
Electric Strength Test Voltage
Input/Ground
Input/Output
Output/Ground
Min
Nom
Max
Units
-
Vac
Vac
Vac
1900Vac
3000Vac
500Vac
1900
3000
1900
-
Connector Information
Input Connector
J1
DC Output Connector
J2
PIN 1) AC Line
PIN 2) Empty (removed)
PIN 3) AC Neutral
Pin 1) (+V)
Pin 2) (+V)
Mating Connector:
Tyco/AMP 640250-3
Pins: 640252-2
Mating Connector:
Tyco/AMP 640250-4
Pins: 640252-2
www.slpower.com
Pin 3) (-V)
Pin 4) (-V)
TB110 REV 1.1
Ground Connector
G1
FG
0.187” Quick-connect tab
Mating Connector:
Molex 01-90020005
12-MAY-16
Signal Connector
J3
PIN 1) RTN
PIN 2) DC_OK
Pin 3) TEMP SEMSOR (+)
Pin 4) TEMP SEMSOR (-)
Mating Connector:
Tyco/AMP 1375820-4
Pins: 1375819
PRELIMINARY
3
TB110S
110W Single Output
Test and Measurement/Industrial Series
Mechanical Drawing
Notes:
1. Overall Dimensions are 2.0:W x 4.0”L x 1.4”H.
2. Height is measured from top of highest
component to longest lead protrusion on
bottom of PCB.
3. Input & Output Connectors on opposite ends.
4. Mounting hole pattern: 1.75” x 3.75”. 4 holes
5. Mounting holes isolated from ground for Class
II designs. Mounting standoff height to be
>/= xx mm.
Characteristic Curves
Output vs. Temperature
110W convection cooled at -20°C to 50°C operating ambient temperature.
Output Power (Watts)
Output Power - Convection vs. Ambient Temperature
www.slpower.com
70
65
60
55
50
45
40
Efficiency curves similar to these with
characteristics of TB110 models will
be inserted herein.
-20
-10
0
10
20
30
40
50
60
70
Ambient Operating Temperature (°C)
TB110 REV 1.1
12-MAY-16
PRELIMINARY
4
TB110S
110W Single Output
Test and Measurement/Industrial Series
Efficiency vs. Loading
The charts below detail the TB110 efficiency vs input voltage and output loading conditions at 25°C, 50°C and 70°C under de-rated power.
25°C ambient
50°C Ambient
92%
92%
115V 12v
230V 12v
90%
115V 15v
115V 12v
91%
Efficiency
Efficiency
91%
230V 12v
90%
115V 15v
Efficiency curves
similar to these with
230V 15v
89%
characteristics115V
of TB110
models will be
24v
inserted herein.
88%
230V 24v
89%
88%
115V 48v
87%
60%
80%
100%
230V 48v
Load (% of rated)
230V 15v
115V 24v
230V 24v
115V 48v
87%
60%
80%
100%
230V 48v
Load (% of rated)
70°C Ambient
92%
115V 12v
Efficiency
91%
230V 12v
90%
115V 15v
89%
230V 15v
115V 24v
88%
230V 24v
115V 48v
87%
60%
80%
100%
Load (% of rated)
230V 48v
Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for
consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.
www.slpower.com
TB110 REV 1.1
12-MAY-16
PRELIMINARY
5