TB110S 110W Single Output Test and Measurement/Industrial Series Features 2” x 4” x 1.3” Package Up to 110W Output Power Compliant to high levels of EMC per EN61000-4 15kV ESD (Air), 8kV (Contact) 4kV Surge Meets Class B Conducted EMI with 6db margin, Class B Radiated EMI with 3db margin Up to 90% Efficiency >10 year e-cap life Universal Input 90-264Vac Input Range DC OK Signal, Inhibit, Power Good Signals 5V @ 1A Standby Output Class I and II Input Models 3 Year Warranty Description A Superior performance 110 Watts AC to DC power supply designed for Test and Measurement and Industrial applications. Feature rich and highly efficient TB110S product family can easily fit in 1U chassis and provides up to 110Watts. Long Life as determined by e-cap life calculations and a 5V@1A standby output are key features. All models are CE marked to low voltage directive and approved to ITE standards of IEC/UL/EN60950 and CSA C22.2, 2nd edition. Model Selection Model Number4 TB110S12K Output Voltage (Nom) 12V TB110S24K 24V 4.3A 3.3A TB110S48K 48V 2.1A 1.6A Notes: 1. 2. 3. 4. Output Current w/Air Convection 8.7A 6.7A Ripple & Noise2 (pk-pk) 120mV Total Regulation OVP Threshold ±2% 15.0 ± 2.0V MTBF3 500,000 89% 240mV ±2% 28.0 ± 2.5V 500,000 89% 480mV ±2% 55.0 ± 4.0V 500,000 Efficiency 89% 1 Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C. Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient temperatures below 0°C. MTBF values are in hours, per Telcordia 332, Issue 6, 25°C, full rated load (w/airflow) at 110Vac input. Change the “K” suffix to “C” for Input Class II (ungrounded) models. General Specifications AC Input 85-264Vac, single phase. (Safety Approved to 90-264Vac). Turn On Time Input Current TBDA at 110Vac, TBDA at 240Vac Rise Time Inrush Current 40Arms Maximum within a half line cycle, cold start at 25C. See application note. Earth Leakage Current <500mA@264Vac, 60Hz input, NC www.slpower.com TB110 REV 1.1 Hold-up Time Over Load Protection (OCP) 12-MAY-16 Main Output: <1 Seconds at 115Vac 5Vsb Output: <250mSec at 115Vac Main Output: <70mSec 5Vsb Output: <70mSec Main Output: 20mSec min. 5Vsb Output: 100mSec min. from loss of AC input at 115 Vac, full load, 25°C. 115% - 200% of rated output current value. Hiccup Mode, Auto-recovery PRELIMINARY 1 TB110S 110W Single Output Test and Measurement/Industrial Series General Specifications Turn-On Input Voltage 70-85Va, Full spec performance at 85Vac. Short Circuit Protection (SCP) Short across the output terminals will not cause damage to the unit. Hiccup Mode , Auto-recovery Turn-Off Input Voltage <75Vac ± 8Vac Over Voltage Protection (OVP) Latches off when output voltage is with range as shown in table. Requires AC Power cycle to reset Input Fuses Output Voltage Voltage Adjustability 3.15A, 250Vac, line and neutral inputs Over Temperature Protection (OTP) 12V to 48Vdc. See models chart for part numbering. Output Reverse Voltage Protection Isolation +/- 10% Power shuts down at temperature of TBD (typical) at full load. Auto-recovery. Outputs protected against momentary reverse current less than 20A peak for less than 10mS with 0.5A average. Sustained reverse current at high levels may damage unit. Input-Output: 3000Vac Input-Ground: 1800Vac Output-Ground: 500Vac 88% - 90% typical at 115/230Vac, 25°C. Turn-On & Operating Temperature -20°C to +70°C. Turn on Temperature = -40°C at >=120Vac Output Power 110W with 200LFM airflow; 80W convection cooled, -20C to 50°C ambient. 85Vac to 264Vac. See chart for de-rating above 50°C. Storage Temperature -40°C to +85°C Transient Response 500µS typ. response time for return to within 0.5% of final value for a 50% load change, ∆i/∆t< 0.2A/µs. Max. volt. deviation is ±3.5%. Altitude Efficiency Minimum Load Total Regulation Relative Humidity Not required. IPC 610 ±2.0 % for all models. Overshoot <2% overshoot at turn-on, <1% overshoot at turnoff, under all conditions. E-Cap Life >10 Years in use condition of 40°C ambient, at 12h/day, 261 days/year. Additional information on other use profiles available on request. Shock (IEC 60068-2-27) Dimensions Operating: Half-sine shock waveform. Impact Acceleration: 20g, Pulse duration: 11mS. Cycles: 3 times per axis in X,Y, Z direction Non-Operating: Half-sine shock waveform. Impact Acceleration: 100g, Pulse duration: 6mS Cycles: 3 times per direction on 3 axes (X,Y. Z) Safety Standards MTBF Vibration (IEC 60068-2-6) (IEC 60068-2-64) Weight W: 2.0” x L: 4.0” x H: 1.4” Operating: -500m to 5000m Non-operating: -500 to 40,000 feet 5% to 95%, non-condensing Class 2 IEC 60950-1, 2nd Edition CAN/CSA – C22.2 No 60950-1 DEMKO EN60950-1 >500,000 hours @ 110/220Vac, 25°C, GB Telcordia 332 issue 3. Operating: Sinusoidal Frequency: 10-500Hz, Impact Acceleration: 1g, Sweep rate: 1 octave/min Cycles: 10 times per axis in X, Y, Z direction Random Vibration: Operating: 0.003g2/Hz, 1.224grms overall, 3 axes, 10 min per axis, 1-500Hz. Non-Operating: 0.02g2/Hz, 3.1grms overall, 3 axes, 1 hour per axis, 20-500 Hz 180g, typical Auxiliary Signals DC OK: Goes HIGH when main DC output is above 90% of nominal voltage and goes LOW when the output is below 90% of rated main output DC voltage Power Good/Power Fail: Signal is high after the main output is within regulation band upon AC turn on. Goes low with 4mS min. before the main DC output drops below 90% of nominal value when AC turns off. Inhibit: Logic HIGH or open = ON Logic LOW or short to ground = OFF 5V Standby Output: 5V @ 1A, +/-5% regulation over all changes in main output load current. www.slpower.com TB110 REV 1.1 12-MAY-16 PRELIMINARY 2 TB110S 110W Single Output Test and Measurement/Industrial Series EMI/EMC Compliance Conducted Emissions EN55022/CISPR22 Class B, FCC Part 15.107, Class B, 6db margin, typical. Radiated Emissions EN55022/CISPR22 Class B, FCC Part 15.109, Class B, 3db margin, typical. Common Mode Noise: High Frequency (100Khz -20 Mhz) Common Mode Noise: Low Frequency (50-120 Hz) <50mA pk-pk, 6mA rms CM current. See Application Note. <50mA pk-pk, 6mA rms CM current. See Application Note. Static Discharge Immunity EN55024/IEC61000-4-2, Level 4, 8kV Contact Discharge, 15kV air discharge, Criteria A Radiated RF Immunity EN55022/IEC61000-4-3, Level 3, 10V/m, Criteria A EFT/Burst Immunity EN55024/IEC61000-4-4, Level 3, 4kV (PS Output), Criteria A; 2kV (signal outputs), Criteria B Line Surge Immunity EN55024/IEC61000-4-5, Level 4, 2kV diff., 4kV Common-mode, Criteria A Conducted RF Immunity EN55022/IEC61000-4-6, Level 3, 10V/m, Criteria A Power Frequency Magnetic Field Immunity EN55024/IEC61000-4-8, Level 4, 30A/m, Criteria A Voltage Dip Immunity EN55024/IEC61000-4-11, Dips: 100%, 10ms; 30%, 500ms; 60%, 100ms; Interruptions: 100%, 5000mS; Performance Criteria A, A, B & B Line Harmonic Emissions EN55024/IEC61000-3-2, Class A. Flicker Test EN55024/IEC61000-3-3 Notes: Performance criteria are based on EN55024. According to the standards, performance criteria are defined as following: A – Normal performance during and after the test B – Temporary degradation, self-recoverable C – Temporary degradation, operator intervention required to recover the operation D – Permanent damage Isolation Specifications Parameter Conditions/Description Insulation Safety Rating Input/Ground Input/Output Output/Ground Electric Strength Test Voltage Input/Ground Input/Output Output/Ground Min Nom Max Units - Vac Vac Vac 1900Vac 3000Vac 500Vac 1900 3000 1900 - Connector Information Input Connector J1 DC Output Connector J2 PIN 1) AC Line PIN 2) Empty (removed) PIN 3) AC Neutral Pin 1) (+V) Pin 2) (+V) Mating Connector: Tyco/AMP 640250-3 Pins: 640252-2 Mating Connector: Tyco/AMP 640250-4 Pins: 640252-2 www.slpower.com Pin 3) (-V) Pin 4) (-V) TB110 REV 1.1 Ground Connector G1 FG 0.187” Quick-connect tab Mating Connector: Molex 01-90020005 12-MAY-16 Signal Connector J3 PIN 1) RTN PIN 2) DC_OK Pin 3) TEMP SEMSOR (+) Pin 4) TEMP SEMSOR (-) Mating Connector: Tyco/AMP 1375820-4 Pins: 1375819 PRELIMINARY 3 TB110S 110W Single Output Test and Measurement/Industrial Series Mechanical Drawing Notes: 1. Overall Dimensions are 2.0:W x 4.0”L x 1.4”H. 2. Height is measured from top of highest component to longest lead protrusion on bottom of PCB. 3. Input & Output Connectors on opposite ends. 4. Mounting hole pattern: 1.75” x 3.75”. 4 holes 5. Mounting holes isolated from ground for Class II designs. Mounting standoff height to be >/= xx mm. Characteristic Curves Output vs. Temperature 110W convection cooled at -20°C to 50°C operating ambient temperature. Output Power (Watts) Output Power - Convection vs. Ambient Temperature www.slpower.com 70 65 60 55 50 45 40 Efficiency curves similar to these with characteristics of TB110 models will be inserted herein. -20 -10 0 10 20 30 40 50 60 70 Ambient Operating Temperature (°C) TB110 REV 1.1 12-MAY-16 PRELIMINARY 4 TB110S 110W Single Output Test and Measurement/Industrial Series Efficiency vs. Loading The charts below detail the TB110 efficiency vs input voltage and output loading conditions at 25°C, 50°C and 70°C under de-rated power. 25°C ambient 50°C Ambient 92% 92% 115V 12v 230V 12v 90% 115V 15v 115V 12v 91% Efficiency Efficiency 91% 230V 12v 90% 115V 15v Efficiency curves similar to these with 230V 15v 89% characteristics115V of TB110 models will be 24v inserted herein. 88% 230V 24v 89% 88% 115V 48v 87% 60% 80% 100% 230V 48v Load (% of rated) 230V 15v 115V 24v 230V 24v 115V 48v 87% 60% 80% 100% 230V 48v Load (% of rated) 70°C Ambient 92% 115V 12v Efficiency 91% 230V 12v 90% 115V 15v 89% 230V 15v 115V 24v 88% 230V 24v 115V 48v 87% 60% 80% 100% Load (% of rated) 230V 48v Data Sheet © 2016 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TB110 REV 1.1 12-MAY-16 PRELIMINARY 5