TU425S Series Datasheet

TU425
425W Single Output
Test and Measurement/Industrial Series
Features

3.3” x 6.2” x 1.62” Package

Up to 425W of Air-Cooled Power, 300W Convection

Universal Input 90-264Vac Input Range

5V at 2A Isolated Standby Output

Isolated 12V Fan Output

Inhibit, Power Fail, DC OK Signals, Remote Sense

Approved to CSA/EN/IEC/UL60950-1, 2nd Edition

Compliant to high levels of EMC per EN61000-4

Meets Class B Conducted EMI with 6db margin,
Class A Radiated EMI with 3db margin

Efficiency 90% typical

3 Year Warranty
Description
A Superior performance 425 Watts AC to DC power supply designed for Test and Measurement and Industrial applications. Feature
rich and highly efficient TU425 product family with active current share for redundant applications can easily fit in 1U chassis and
provides 300 Watts for convection or 425 Watts with moving air. Input & output monitoring alarms plus isolated 12V/1A fan output
and 5V/2A standby voltage are among other standard offering of TU425 family. All models are CE marked to low voltage directive
and approved to ITE standards of IEC/UL/EN60950 and CSA C22.2, 2nd edition.
Model Selection
Model
Number
TU425S12E
TU425S18E
TU425S24E
TU425S48E
TU425S56E
Notes:
1.
2.
3.
4.
5.
6.
7.
Volts
12V
5Vsb
12V Fan5
18V
5Vsb
12V Fan5
24V
5Vsb
12V Fan5
48V
5Vsb
12V Fan5
56V³
5Vsb
12V Fan5
Output Current
w/200LFM air¹
Convection²
32.2A
22.0A
2.0A
2.0A
1.0A
0.5A
21.4A
14.6A
2.0A
2.0A
1.0A
0.5A
16.8A
11.9A
2.0A
2.0A
1.0A
0.5A
8.4A
5.9A
2.0A
2.0A
1.0A
0.5A
7.2A
5.1A
2.0A
2.0A
1.0A
0.5A
Efficiency³
(Main Output)
88%
88%
90%
90%
90%
Ripple & Noise4
(mV pk-pk)
120mV
100mV
360mV
180mV
100mV
360mV
240mV
100mV
360mV
480mV
100mV
360mV
560mV
100mV
360mV
Total
Regulation
±3%
±5%
±10%
±3%
±5%
±10%
±3%
±5%
±10%
±3%
±5%
±10%
±3%
±5%
±10%
OVP
Threshold
14.0 ± 1.1V
5.5V – 8.0V
N/A
21.0 ± 2.0V
5.5V – 8.0V
N/A
28.0 ± 2.5V
5.5V – 8.0V
N/A
55.0 ± 4.0V
5.5V – 8.0V
N/A
63.0 ± 4.0V
5.5V – 8.0V
N/A
MTBF7
389,750
356,330
355,520
354,722
354,560
Total power with 200lfm of forced air cooling is 425W (385W for 12V model) including 12V/1A for Fan output and 5V/2A standby.
Maximum convection cooled power is limited to 280W for 12V model and 300W for other models. This includes 12V/0.5A fan output and 5V/2A standby output.
Efficiency values listed are typical and are measured at 115Vac input, full load output current, at an ambient temperature of 25°C.
Measured at 25°C ambient with noise probe directly at end of 6” twisted pair terminated with 0.1μF ceramic and 10μF low ESR capacitors. Values will be higher at ambient
temperatures below 0°C.
Fan Output: If the load on this output is other than a fan, a short circuit condition on this output can only be remedied by removing both the cause of the short circuit and the
load. This will allow the output to resume normal operation.
No output adjustment for 56V model.
MTBF values are in hours, per Telcordia 332, Issue 6, 25°C, full rated load (w/airflow) at 110Vac input.
www.slpower.com
TU425 REV 2.8
29-MAY-15
1
TU425
425W Single Output
Test and Measurement/Industrial Series
General Specifications
AC Input
Input Current
Inrush Current
Input Fuses
Earth Leakage
Current
Power Factor
Efficiency
Output Power
Main output: <1 sec. max @115Vac, rise time 30mS
max. 5Vsb turn-on time is 500mS max., rise time
50mS max. Output Voltage rise is monotonic.
100-240Vac, ±10%, 47-63Hz, 1∅
120–300Vdc (external fuse required for DC input)
Turn On Time
115Vac: 5.2A, 230Vac: 2.5A
Hold-up Time
Main Output: >20ms for 300W @ 120Vac/60 Hz,
>16ms for 383W (90% of 425W) @ 120v/60Hz.
5Vsb Output: >500mS
Overtemperature
Protection
Sensing transformer temperature, 135°C (55°C
ambient temperature at full load), auto recovery.
264Vac, cold start: will not exceed 40Arms
within ½ cycle. I²T = 25A²/Sec maximum
(Main Output)
Overload Protection
F1, F2: 6.3A, 250Vac
130 to 170% of rating, Hiccup Mode, auto recovery.
<750μA@264Vac, 60Hz, NC
<1.5mA@264Vac, 60Hz, SFC
Short Circuit
Protection
Main Output & 5Vsb: Cycling type, auto recovery.
Fan Output: recovery only after removal of short and
load. See note 5 on page 1.
>0.99 @ 115Vac, Full Load
>0.95 @ 230Vac, Full Load
Overvoltage
Protection
OVP latch, see chart for trip ranges.
5V standby output (latch), see chart for trip range.
See Model Selection Chart on page 1.
Switching Frequency
425W continuous, with 200 lfm airflow
300W convection cooled – See chart for specific
voltage model ratings.
Isolation
75kHz, typical
Input-Output: 4000Vac
Input-Ground: 1800Vac
Output-Ground: 1500Vdc
-10 to 70°C. Starts up at -40°C. The unit will meet
all published specifications after a warm-up period.
See Application Note for operating conditions during
start-up.
Transient Response
50% load step, ∆i/∆t: <0.2A/μS. Max Voltage
Deviation = 5%. Recover to within 1% of nominal
within 500µS
Operating
Temperature
Ripple and Noise
0.5%rms, 1% pk-pk, see Model Selection Chart on
page 1.
Temperature
Derating
Derate output power linearly above 50°C to 50% at
70°C
Storage
Temperature
-40°C to +85°C
Common Mode
Noise
Output Voltage
Minimum Load
Total Regulation
Vibration
Dimensions
Weight
www.slpower.com
Line Frequency: <2.5Vrms @115Vac, <5Vrms@
230Vac, 50/60Hz. See App Note for test
set-up and typical graphs. For high frequency
noise, consult the factory.
See chart on page 1. Initial setpoint within 0.5%
of nominal. Adjustable +/-5% from nominal
(except 56V)
Not required for main output or 5Vsb.
Fan Output: 0.5A min required on the main
output in order for the 12V Fan output to be
within regulation.
Altitude
Relative Humidity
Shock
See Model Selection Chart on page 1.
Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10
min/axis
Non-Operating: 0.026g2/Hz, 5.0grms overall, 3
axes, 1 hr/axis
5% to 95%, non-condensing
Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks
total
Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6
shocks total
Safety Standards
EN/CSA/UL/IEC 60950-1, 2nd Edition
MTBF
See Model Selection Chart on page 1.
W: 3.3” x L: 6.2” x H: 1.62”
W: 84mm x L: 157.5mm x H: 41mm
E-Cap Life
670g
TU425 REV 2.8
Operating: up to 5000m (derating may be required
above 3000m, consult factory)
Non-operating: -500 to 40,000 ft.
29-MAY-15
7 years, based on typical operation of 12 hours/day,
261 days/year at 40°C ambient temp.
2
TU425
425W Single Output
Test and Measurement/Industrial Series
Auxiliary Signals
DC OK:
Goes HIGH when main DC output is above 90%
of nominal voltage and goes LOW when the
output is below 90% of rated main output DC
voltage
Inhibit:
Logic HIGH or open = ON
Logic LOW or short to ground = OFF
Remote Sense:
5V Standby Output:
Power Good/ Power
Fail:
Fan Output:
Compensates for up to 0.5V voltage drop
for 48V & 56V models, and 0.16V voltage drop
for 12V & 24V models. Maximum deviation of
5% (main output) any 50% step above 5% load.
Current Share¹:
Current Share
Accuracy¹:
5V @ 2A, +/-5% regulation over all
changes in main output load current.
Signal is high within 500mS after the main output is
within regulation band upon AC turn on. Goes low
with 4 mS min. before the main DC output drops
below 90% of nominal value when AC turns off.
12V @ 1 A (air cooled ) or 0.5A (convection),
+/-10% regulation for load change of 0.5A to FL on the
main output.
Active single wire, up to 4 supplies in parallel. Paralleled
output voltages must be set to within 0.5% of each
other. Contact Factory for details on the required set-up
for proper operation.
5% when the load current is ≥50% of the total
available load current, 10% when the load current is
between 25% - 49% of the total available load current.
Remote sense lines must be connected to ensure
accuracy.
Notes: 1. Consult Factory for proper set-up for current sharing operation.
EMI/EMC Compliance
Conducted Emissions
EN55011/CISPR22 Class B, FCC Part 15.107, Class B, 6db margin, typical.
Radiated Emissions
EN55011/CISPR22 Class A, FCC Part 15.109, Class A, 3db margin, typical.
Static Discharge Immunity
EN55024/IEC61000-4-2, Level 4, 8kV Contact Discharge, 15kV air discharge, Criteria A
Radiated RF Immunity
EN55022/IEC61000-4-3, Level 2, 3V/m, Criteria A
EFT/Burst Immunity
EN55024/IEC61000-4-4, Level 3, 2kV (PS Output), 1kV (signal outputs), Criteria A
Line Surge Immunity
EN55024/IEC61000-4-5, Level 3, 1kV diff., 2kV common-mode, Criteria A
Level 4, 2kV diff., 4kV Common-mode, Criteria C
Conducted RF Immunity
EN55022/IEC61000-4-6, Level 3, 10V/m, Criteria A
Power Frequency Magnetic Field Immunity
EN55024/IEC61000-4-8, Level 3, 10A/m, Criteria A
Voltage Dip Immunity
EN55024/IEC61000-4-11, Dips: 100%, 10ms; 30%, 500ms; 60%, 100ms;
Interruptions: 100%, 5000mS; Performance Criteria A, A, B & B
Line Harmonic Emissions
EN55024/IEC61000-3-2, Class A, C & D at full load (425W output).
Flicker Test
EN55024/IEC61000-3-3, Section 5
Connector Information
Input Connector
J101
Main DC Output
J302, J303
Fan Output
J301
Signal Connector
J401
PIN 1) FG
PIN 2) NC
PIN 3) AC Neutral
PIN 4) NC
PIN 5) AC Line
Term 1 – J302: (+V)
Term 2 – J303: (─V)
PIN 1) 12V Fan (+)
PIN 2) 12V Fan (─)
PIN 1)
PIN 2)
PIN 3)
PIN 4)
PIN 5)
Mating Connector:
Tyco/AMP 640250-5
Pins: 3-770476-1
Mating Connector:
Molex 19141-0058
19141-0063
19141-0083
Mating Connector:
Tyco AMP 1375820-2
Pins: 1375819-1
Mating Connector:
Molex 90142-0010
Pins: 90119-2110
www.slpower.com
TU425 REV 2.8
29-MAY-15
Remote Sense (+)
Common
Remote Sense (─)
Current Sharing
Remote Inhibit
Pin 6)
Pin 7)
Pin 8)
Pin 9)
Pin 10)
Power Good
+5Vsb Output
+5Vsb Output
DC OK
Common
3
TU425
425W Single Output
Test and Measurement/Industrial Series
Airflow Direction
Mechanical Drawing
Notes:
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is ±0.02”.(±0.5).
3. FG is safety ground connection
4. Specifications are for convection rating at factory settings
at 115 Vac input 25 °C unless otherwise stated.
5. Warranty: 3 years.